This is a Hazmat Survey document prepared for the State of Utah Division of Facilities Construction and Management (DFCM) related to a Construction Stage II Invitation to Bid for the Cedar City Administration & Lab Building Management System (BMS) Upgrade project. The project involves replacing existing VAV boxes and finned tube components, upgrading all building controls systems, and installing new variable frequency drives (VFDs) for hot water pumps at the Cedar City Administration facility. Only contractors who have been prequalified under the Stage I Prequalification for Contractors process and appear on the DFCM Prequalified Contractors list as of the solicitation date are eligible to submit bids on this project.

The construction cost estimate for this project is $486,773.00. The document serves as a preliminary hazmat assessment survey to identify any hazardous materials present at the facility that may require remediation or special handling procedures during the construction and renovation work. This assessment is essential for ensuring contractor safety compliance and proper environmental protocols throughout the project execution. All prequalified contractors must review this hazmat survey documentation as part of their bid preparation process to accurately account for any additional costs or precautions related to hazardous materials management.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS (LIMITED), LEAD (LIMITED), AND HAZARDOUS MATERIALS

INSPECTION, SURVEY AND ASSESSMENT

FOR THE

UTAH DEPARTMENT OF TRANSPORTATION

CEDAR CITY ADMINISTRATION BUILDING

1470 NORTH AIRPORT ROAD

CEDAR CITY, UTAH 84720

A LIMITED ASBESTOS SURVEY AND ASSESSMENT

FOR THE

UTAH DEPARTMENT OF TRANSPORTATION

CEDAR CITY ADMINISTRATION BUILDING

September 14, 2026

Prepared for:

Mrs. Aubrey Stapel Hazmat Program Manager

Utah Department of Government Operations Division of Facilities, Construction and Management (DFCM)

Taylorsville State Office Building, 3rd Floor 4315 South 2700 West

Taylorsville, Utah 84114

PH: (801) 641-0964

Prepared by:

R & R Environmental, Inc. (R & R) 47 West 9000 South, Suite #2

Sandy, Utah 84070 jamison@rrenviro.com Phone (801) 928-1560

TABLE OF CONTENTS

ASBESTOS

1.0 INTRODUCTION

2.0 EXECUTIVE SUMMARY

3.0 SAMPLING METHODS

4.0 SURVEY RESULTS

5.0 CONCLUSIONS

6.0 LIMITATIONS AND EXCLUSION OF WARRANTY.……………………………………………………6

List of Appendices

Appendix A Sample Log

Appendix B Administration Report

Appendix C Photo Log

Appendix D Floor Plans

Appendix E State of Utah Certifications

Asbestos Survey Report Page 1 Utah Department of Transportation Cedar City Administration Building

1.0 INTRODUCTION

R & R Environmental, Inc. (R & R) was contacted to conduct a limited asbestos survey for the Utah Department of Transportation, Cedar City Administration Building located at 1470 North Airport Road in Cedar City, Utah 84720. Various components of the HVAC system in the building are going to be removed and replaced. The survey consisted of a visual assessment of the building for suspect asbestos containing materials (ACM) and bulk sampling of the materials. The fieldwork component of this survey was conducted by Mr. Trevor Thacker who is a Utah Certified Asbestos Building Inspector.

This report presents the conditions and observations noted on the visit dates.

The following general information is included in this survey report:

• Executive Summary (Section 2.0)

• Sampling Methods (Section 3.0)

• Analytical Results (Section 4.0)

• Conclusions (5.0)

• Limitations & Exclusion of Warranty (6.0)

Asbestos Survey Report Page 2

2.0 EXECUTIVE SUMMARY

No material(s) containing asbestos or assumed to contain asbestos were identified during this limited survey.

Asbestos Survey Report Page 3

UTAH DEPARTMENT OF TRANSPORATION, CEDAR CITY ADMINISTRATION BUILDING

1470 NORTH AIRPORT ROAD, CEDAR CITY, UTAH 84720

DATE OF SURVEY: SEPTEMBER 2026

NESHAP - REGULATED

ASBESTOS-CONTAINING MATERIALS (R-ACM)

1. Friable asbestos material (>1% asbestos and can be crumbled, pulverized, or reduced to powder by hand pressure) Thermal system insulation (TSI)* Textured ceiling material (TCM)* (Wallpaper) Spray-on insulation or fireproofing* Blown-in insulation* Ceiling tiles/panels* Plaster, gypsum board, gypsum board joint compound* (Plaster & Concrete Surfacing) Cloth materials* (Boiler Flue Gasket) Paper materials* (HVAC Paper Tape and Insulating Board) Electrical wiring insulation* Sink undercoating (loose)* Other* (Boiler & Fire Rated Curtain)

2. Category I ACM which has become friable

Packings Gaskets Resilient floor coverings (floor tile and sheet vinyl) Asphalt roofing products (Dust Debris, Roofing Underlayment Debris, Flashing Material)

3. Category I ACM that will be or has been subjected to sanding, grinding, cutting, or abrading

Packings Gaskets Resilient floor coverings (floor tile and sheet vinyl) Asphalt roofing products

4. Category II ACM that has a high probability of becoming or has become friable during demolition or renovation operations Asbestos cement materials (TransiteT)* Asphalt, tar and rubber-base ACM products other than roofing products* Non-asphalt and non-paper roofing products* Paint* Fire brick and/or mortar* Stainless steel sink undercoating (solid)* Encapsulated TCM* Encapsulated TSI* Mastic for floor tile, ceiling tile, cove molding, etc.* Other (Fire Rated Door/Frame)

Asbestos Survey Report Page 4

UTAH DEPARTMENT OF TRANSPORATION, CEDAR CITY ADMINISTRATION BUILDING

1470 NORTH AIRPORT ROAD, CEDAR CITY, UTAH 84720

DATE OF SURVEY: SEPTEMBER 2026

NESHAP NON-REGULATED

ASBESTOS-CONTAINING MATERIAL (N-R-ACM)

1. > 1% asbestos

2. Category I Non-friable (cannot be crumbled, pulverized, or reduced to powder by hand pressure) ACM with >1% asbestos by new PLM procedure Packings (Caulk and Window Glazing) Gaskets (HVAC Sealant, Black) Resilient floor coverings (Floor Tile) Asphalt roofing products

3. Category II Non-friable ACM with >1% asbestos by new PLM procedure (Category includes items meeting Category I definition but not specifically listed in that category) Asbestos cement materials (TransiteT)* (Fume hoods, counter tops, and window panels) Asphalt, tar and rubber-base ACM products other than roofing products* Non-asphalt and non-paper roofing products* Paint* (Silver Paint Sealant) Fire brick and/or mortar* Sink undercoating (solid)* Mastic for floor tile, ceiling tile, cove molding, etc.* Other*

Notes:

1. (*) Denotes R&R’s interpretation of materials included in this category.

2. New PLM procedure is outlined in Appendix A, Subpart F, 40 CFR, Part 783, Section 1, Polarized

Light Microscopy.

3. The Environmental Protection Agency (EPA) National Emission Standard for Hazardous Air

Pollutants (NESHAP) asbestos revision as outlined in 40 CFR, Part 61, became effective November 20, 1990. The asbestos classification system outlined in the revision and included in this section is dynamic in nature. Asbestos materials classified as “NON-REGULATED” at the time of the survey may become “REGULATED” due to ongoing or planned maintenance, renovation, or demolition actions, which can transform a material containing greater than 1% asbestos from a “non-friable” and NON-REGULATED to a friable and REGULATED condition. Classification of ACM in this section and in the executive summary of this report is, therefore, based on the observations of the surveyor at the time of the survey and may or may not be appropriate at later dates.

4. Maintenance, renovation, demolition, weathering, normal wear, water, or other damage can alter the “NON-REGULATED” status of materials, and necessitate precautions required for handling them as “REGULATED” asbestos-materials.

Asbestos Survey Report Page 5

3.0 SAMPLING METHODS

Survey procedures were based on those outlined in Title 40 Code of Federal Regulation (CFR) Part 763, USEPA Asbestos Hazard Emergency Response Act, and the Asbestos Model Accreditation Plan (effective April 4, 1994). The procedures included visual observation, physical inspection, bulk sample collection, and condition assessment of suspect ACM. The number of samples collected was based on the amount and accessibility of each homogeneous material, with consideration given for the type, age, and condition.

Twenty-six (26) samples were collected from the suspect materials to assess the presence of asbestos (or lack thereof) in building materials/systems. Each sample collected was placed into a sealable plastic bag or tub, marked with a unique sample identification code, and packaged for subsequent shipment to the Administration for analysis. Individual sample identification consisted of a numeric code denoting the sampling media/location.

After packaging and labeling, samples were submitted under proper chain-of-custody to Reservoirs Environmental, Inc., Denver, Colorado. The National Voluntary Administration Accreditation Program (NVLAP), Lab Code 101896 accredits Reservoirs for asbestos analysis.

Samples were analyzed via Polarized Light Microscopy (PLM) utilizing EPA Method 600/M4- 82-020. Please note that USEPA and OSHA regulations define an ACM as a material containing more than one (1) percent asbestos, by volume, as determined by PLM analysis. In the case of multi-layer systems (e.g., floor tile/mastic layers), the Administration analyzed and reported each layer separately.

4.0 SURVEY RESULTS

Twenty-six (26) representative samples collected were submitted for analytical determination. A summary of analytical results for samples collected and analyzed for this survey are in Appendix B (Administration Results) and are discussed below by building material/system type. Photographs of the buildings where samples were taken are included as Appendix C. Floor Plans of the building where samples were taken are included in Appendix D

Asbestos Survey Report Page 6

5.0 CONCLUSIONS

No materials containing asbestos were identified during the limited survey.

6.0 LIMITATIONS AND EXCLUSION OF WARRANTY

This asbestos survey and assessment was performed using procedures and a level of diligence typically exercised by professional consultants performing similar services. However, asbestos-containing material (ACM) can be present in a structure, but not identified using ordinary investigative procedures.

No asbestos survey can completely, eliminate uncertainty regarding the presence of ACM.

R&R Environmental, Inc.’s level of diligence and investigative procedures are intended to reduce, but not eliminate, potential uncertainty regarding the presence of ACM. The procedures used for this survey attempt to establish a balance between the competing goals of limiting investigative costs, time, and building damage, and reducing the uncertainty about unknown conditions. Therefore, the determinations in this report should not be construed as a guarantee that all ACM present in the subject property has been included in this report.

This report presents R&R Environmental, Inc.’s professional determinations, which are dependent upon information obtained during performance of consulting services. R&R Environmental, Inc. assumes no responsibility for omissions or errors resulting from inaccurate information provided by sources outside of R&R Environmental, Inc.

No warranty or guarantee, expressed or implied, is made regarding the findings, conclusions, or recommendations contained in this report. The limitations presented above supersede the requirements or provisions of all other contracts or scopes of work, implied, or otherwise, except stated or acknowledged herein.

Asbestos Survey Report Page 7

A LIMITED ASBESTOS SURVEY AND ASSESSMENT

OF THE

UTAH DEPARTMENT OF TRANSPORTATION

CEDAR CITY ADMINISTRATION BUILDING

During the month of September 2026, R & R Environmental, Inc. (R & R) of Sandy, Utah, conducted a limited asbestos survey and assessment of the Utah Department of Transportation, Cedar City Administration Building, located at 1470 North Airport Road in Cedar City, Utah 84720. Bulk samples of suspect asbestos-containing materials were collected and analyzed. The condition of all friable and non-friable asbestos-containing materials was assessed. The following accredited inspector conducted the survey and assessment.

Inspected by:

Trevor Thacker Date State of Utah, Division of Air Quality Inspector Certification Number: ASB-8872 State of Utah Company Certification: ASBC-237

This report was reviewed by:

David C. Roskelley, MSPH, CIH, CSP Date State of Utah, Division of Air Quality Inspector Certification Number: ASB-1370 AHERA Inspector #5 PSI 65451 I Certified Safety Professional #15774 Certified Industrial Hygienist #8529 State of Utah Company Certification: ASBC-237

Appendix A

Sample Log

SAMPLE LOG

Sample

Material/ Homogenous Area Sample Location Quantity

Lab Result (%/Type) Assessment

B-01 Wall System Storage Rm 1,100 ft2 None Detected Undamaged B-02 Wall System Storage Rm 1,100 ft2 None Detected Undamaged B-03 Wall System Storage Rm 1,100 ft2 None Detected Undamaged B-04 Wall System Server Rm 1,100 ft2 None Detected Undamaged B-05 Wall System Maintenance Rm 1,100 ft2 None Detected Undamaged

B-06 Vinyl Cove Base (Brown) & Mastic Maintenance Rm 68 ft2 None Detected Undamaged

B-07 Vinyl Cove Base (Brown) & Mastic Maintenance Rm 68 ft2 None Detected Undamaged

B-08 Pipe Thread Sealant Maintenance Rm 10 ft2 None Detected Undamaged B-09 Pipe Thread Sealant Maintenance Rm 10 ft2 None Detected Undamaged B-10 TSI-Mudded Fitting Maintenance Rm 2 ft2 None Detected Undamaged B-11 TSI-Mudded Fitting Maintenance Rm 2 ft2 None Detected Undamaged B-12 Vent Sealant (White) Maintenance Rm 1 ft2 None Detected Undamaged B-13 Vent Sealant (White) Maintenance Rm 1 ft2 None Detected Undamaged B-14 Vent Liner Storage Rm 20 ft2 None Detected Undamaged B-15 Vent Liner Storage Rm 20 ft2 None Detected Undamaged

B-16 Above Ceiling Construction Material NW Hall 10 ft2 None Detected Undamaged

B-17 Above Ceiling Construction Material NW Hall 10 ft2 None Detected Undamaged

B-18 TSI-End Sealant Maintenance Rm 30 ft2 None Detected Undamaged B-19 TSI-End Sealant Maintenance Rm 30 ft2 None Detected Undamaged B-20 Wall Penetration IT Rm 1 ft2 None Detected Undamaged B-21 Wall Penetration IT Rm 1 ft2 None Detected Undamaged

Material/ Homogenous Area Sample Location Quantity

Lab Result (%/Type) Assessment

B-22 Duct Wrap NW Hall 15 ft2 None Detected Undamaged B-23 Duct Wrap NW Hall 15 ft2 None Detected Undamaged B-24 Ceiling Panel NW Hall 1 ft2 None Detected Undamaged B-25 Ceiling Panel NW Hall 1 ft2 None Detected Undamaged B-26 TSI-End Sealant Maintenance Rm 30 ft2 None Detected Undamaged

Appendix B

Labratory Report

September 03, 2026

Sincerely, Jeanne Spencer President

Subcontractor Number:

Laboratory Report: RES 782938-1

Project #/P.O. #: UDOT Cedar Office Bldg

Project Description: Bulk Samples

Trevor Thacker R & R Environmental 47 West 9000 South #2 Sandy, UT 84070

Dear Trevor, Eurofins Reservoirs is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA LAP), Lab ID 101533 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.

Eurofins Reservoirs has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.

RES 782938-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Eurofins Reservoirs will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed, as received and with the information provided by the customer (i.e. sample volumes and areas). This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Eurofins Reservoirs. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.

by Camryn Baumgartner

09/03/202609/03/202609/03/202609/03/2026

Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual

Effective July 28, 2026 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf

(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com

4955 Yarrow St, Suite 100, Arvada, CO 80002

Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non- AAAA SubSubSubSub AsbestosAsbestosAsbestosAsbestos FibrousFibrousFibrousFibrous YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents

Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 782938 -782938 -782938 -782938 - B1B1B1B1 A Off-white tape 9 NDNDNDND 95 5.0 B Cream joint compound w/ light-gray paint 30 NDNDNDND 0 100.0 C Tan/beige drywall 61 NDNDNDND 40 60.0 782938 -782938 -782938 -782938 - B2B2B2B2 A Off-white tape 8 NDNDNDND 95 5.0 B Cream joint compound w/ light-gray paint 12 NDNDNDND 0 100.0 C Tan/off-white drywall 80 NDNDNDND 35 65.0 782938 -782938 -782938 -782938 - B3B3B3B3 A Off-white tape 7 NDNDNDND 95 5.0 B Cream joint compound w/ light-gray paint 13 NDNDNDND 0 100.0 C Tan/off-white drywall 80 NDNDNDND 30 70.0 782938 -782938 -782938 -782938 - B4B4B4B4 A Off-white adhesive 4 NDNDNDND 0 100.0 B Brown cove base 96 NDNDNDND 0 100.0 782938 -782938 -782938 -782938 - B5B5B5B5 A Off-white adhesive 5 NDNDNDND 0 100.0 B Brown cove base 95 NDNDNDND 0 100.0 782938 -782938 -782938 -782938 - B6B6B6B6 A Gray fibrous material 7 NDNDNDND 40 60.0 B Tan resinous material w/ white resinous material 93 NDNDNDND 6 94.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual

Effective July 28, 2026 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf

Job Number:

Client:

Client Project/P.O.:

Client Project Description:

Date Samples Received:

Analysis Type:

Turnaround:

Date Samples Analyzed:

782938-1 R & R Environmental UDOT Cedar Office Bldg Bulk Samples September 02, 2026 EPA 600/R-93/116 - Short Report, Bulk Priority September 03, 2026

EUROFINS RESERVOIRS ENVIRONMENTAL, INC

NVLAP Lab Code 101896-0

AIHA LAP, LLC. LAB ID 101533

TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite

(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com

Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-

YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents

Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%)

782938 -782938 -782938 -782938 - B7B7B7B7 A Tan resinous material 20 NDNDNDND 6 94.0 B White speckled material w/ gray resinous material 80 NDNDNDND 0 100.0 782938 -782938 -782938 -782938 - B8B8B8B8 A White sealant 30 NDNDNDND 0 100.0 B Yellow/tan insulation 70 NDNDNDND 90 10.0 782938 -782938 -782938 -782938 - B9B9B9B9 A White sealant 35 NDNDNDND 4 96.0 B Yellow insulation 65 NDNDNDND 90 10.0 782938 -782938 -782938 -782938 - B10B10B10B10 A Light-gray resinous material 100 NDNDNDND 0 100.0 782938 -782938 -782938 -782938 - B11B11B11B11 A Light-gray resinous material 100 NDNDNDND 0 100.0 782938 -782938 -782938 -782938 - B12B12B12B12 A White paint w/ white resinous material 3 NDNDNDND 0 100.0 B Brown insulation 97 NDNDNDND 90 10.0 782938 -782938 -782938 -782938 - B13B13B13B13 A White paint w/ white resinous material 5 NDNDNDND 0 100.0 B Black resinous material 9 NDNDNDND 0 100.0 C Brown insulation 86 NDNDNDND 90 10.0 782938 -782938 -782938 -782938 - B14B14B14B14 A Beige fibrous perlitic material 45 NDNDNDND 75 25.0 B White drywall plaster 55 NDNDNDND 6 94.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual

Effective July 28, 2026 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf

Job Number:

Client:

Client Project/P.O.:

Client Project Description:

Date Samples Received:

Analysis Type:

Turnaround:

Date Samples Analyzed:

782938-1 R & R Environmental UDOT Cedar Office Bldg Bulk Samples September 02, 2026 EPA 600/R-93/116 - Short Report, Bulk Priority September 03, 2026

EUROFINS RESERVOIRS ENVIRONMENTAL, INC

NVLAP Lab Code 101896-0

AIHA LAP, LLC. LAB ID 101533

TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite

(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com

Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-

YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents

Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 782938 -782938 -782938 -782938 - B15B15B15B15 A White/gray ceiling tile 100 NDNDNDND 75 25.0 782938 -782938 -782938 -782938 - B16B16B16B16 A Tan insulation w/ white/silver wrap 100 NDNDNDND 80 20.0 782938 -782938 -782938 -782938 - B17B17B17B17 A Tan insulation w/ white/silver wrap 100 NDNDNDND 80 20.0 782938 -782938 -782938 -782938 - B18B18B18B18 A Gray resinous material 100 NDNDNDND 0 100.0 782938 -782938 -782938 -782938 - B19B19B19B19 A Gray resinous material 100 NDNDNDND 0 100.0 782938 -782938 -782938 -782938 - B20B20B20B20 A Yellow insulation w/ tan/silver wrap 100 NDNDNDND 80 20.0 782938 -782938 -782938 -782938 - B21B21B21B21 A Yellow insulation w/ tan/silver wrap 100 NDNDNDND 80 20.0 782938 -782938 -782938 -782938 - B22B22B22B22 A White/gray ceiling tile 100 NDNDNDND 65 35.0 782938 -782938 -782938 -782938 - B23B23B23B23 A White/gray ceiling tile 100 NDNDNDND 65 35.0 782938 -782938 -782938 -782938 - B24B24B24B24 A Yellow insulation w/ tan/silver wrap 100 NDNDNDND 80 20.0 782938 -782938 -782938 -782938 - B25B25B25B25 A Yellow insulation w/ tan/silver wrap 100 NDNDNDND 80 20.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

John McIntyre Analyst

Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual

Effective July 28, 2026 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf

Job Number:

Client:

Client Project/P.O.:

Client Project Description:

Date Samples Received:

Analysis Type:

Turnaround:

Date Samples Analyzed:

782938-1 R & R Environmental UDOT Cedar Office Bldg Bulk Samples September 02, 2026 EPA 600/R-93/116 - Short Report, Bulk Priority September 03, 2026

EUROFINS RESERVOIRS ENVIRONMENTAL, INC

NVLAP Lab Code 101896-0

AIHA LAP, LLC. LAB ID 101533

TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite

(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com

SUBMITTED BY INVOICE TO

Client Sample ID Number

RES Job #: 782938

CONTACT INFORMATION SERIES

ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES

CHEMISTRY LABORATORY

MICROBIOLOGY LABORATORY

**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**

Laboratory Analysis Instructions

(Sample ID's must be unique)

Company: R & R Environmental Company: R & R Environmental

Address: 47 West 9000 South #2 Address: 47 West 9000 South #2

Sandy, UT 84070 Sandy, UT 84070

Project Number and/or P.O. #: UDOT Cedar Office Bldg Project Zip Code:

Project Description/Location: Bulk Samples

Contact: Trevor Thacker -1 PLM Priority Phone: (435) 229-9174

Fax:

Cell: (435) 229-9174

Final Data Deliverable Email Address:

tthacke2008@yahoo.com (+ 3 ADDNL. CONTACTS)

PLM / PCM / TEM / NYS DTL RUSH PRIORITY STANDARD Air = A Bulk = B

Dust = D Food = F

Paint = P Soil = S

Dust RUSH PRIORITY STANDARD

*PRIOR NOTICE REQUIRED FOR SAME DAY TAT

Surface = SU Swab = SW

Tape = T Wipe = W

Metals RUSH PRIORITY STANDARD Drinking Water = DW

Waste Water = WW

Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**

Viable Analysis** PRIORITY STANDARD

**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH

Medical Device Analysis RUSH STANDARD

Mold Analysis RUSH PRIORITY STANDARD

Special Instructions:

ASBESTOS CHEMISTRY MICROBIOLOGY ICO

1 B1 X B

2 B2 X B

3 B3 X B

4 B4 X B

5 B5 X B

6 B6 X B

7 B7 X B

8 B8 X B

9 B9 X B

10 B10 X B

11 B11 X B

12 B12 X B

13 B13 X B

P L

M

P L

M S h o rt R ep o rt (E

PA

/6

/R

-9 3/

6)

T E

M

P C

M

N Y

S

D U

S T

M E

TA

L

S

O R

G A

N

IC

S

V

IA

B L

E S

M E

D

IC

A L

M O

L D

S am pl e

V ol um e

(L

A re a

S am pl e

Te m pe ra tu re

C

Le ng th (o r A liq uo ts

) x W id th

(o r A re a/

A liq uo t)

M at rix C od e of

C on ta in er s

D at e C ol le ct ed m m

/d d/ yy

T im e C ol le ct ed hh :m m

Eurofins Reservoirs Environmental, Inc establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.

Eurofins Reservoirs Environmental, Inc will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET30. Failure to comply with payment terms may result in a 18% APR finance charge.

Relinquished By:

Trevor Thacker Date/Time: 09/01/2026 15:33:01 Sample Condition: Acceptable

Received By:

Jessica Strait Date/Time: 09/02/2026 11:44:42 Carrier: Fed-Ex

Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual

Effective July 28, 2026 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf

(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com

REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES

Laboratory Analysis Instructions

(Sample ID's must be unique)

Air = A Bulk = B

Dust = D Food = F

Paint = P Soil = S

Surface = SU Swab = SW

Tape = T Wipe = W

Drinking Water = DW

Waste Water = WW

**ASTM E1792 approved wipe media only**

RES Job #: 782938

Submitted By: R & R Environmental

14 B14 X B

15 B15 X B

16 B16 X B

17 B17 X B

18 B18 X B

19 B19 X B

20 B20 X B

21 B21 X B

22 B22 X B

23 B23 X B

24 B24 X B

25 B25 X B

P L

M

P L

M S h o rt R ep o rt (E

PA

/6

/R

-9 3/

6)

T E

M

P C

M

N Y

S

D U

S T

M E

TA

L

S

O R

G A

N

IC

S

V

IA

B L

E S

M E

D

IC

A L

M O

L D

S am pl e

V ol um e

(L

A re a

S am pl e

Te m pe ra tu re

C

Le ng th (o r A liq uo ts

) x W id th

(o r A re a/

A liq uo t)

M at rix C od e of

C on ta in er s

D at e C ol le ct ed m m

/d d/ yy

T im e C ol le ct ed hh :m m

Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual

Effective July 28, 2026 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf

(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com

September 11, 2026

Sincerely, Jeanne Spencer President

Subcontractor Number:

Laboratory Report: RES 785420-1

Project #/P.O. #: DFCM

Project Description: UDOT MAIN OFFICE CEDAR CITY

Craig Ford R & R Environmental 47 West 9000 South #2 Sandy, UT 84070

Dear Craig, Eurofins Reservoirs is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA LAP), Lab ID 101533 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.

Eurofins Reservoirs has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.

RES 785420-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Eurofins Reservoirs will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed, as received and with the information provided by the customer (i.e. sample volumes and areas). This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Eurofins Reservoirs. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.

by Camryn Baumgartner

09/11/202609/11/202609/11/202609/11/2026

Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual

Effective July 28, 2026 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf

(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com

Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-

YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents

Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 785420 -785420 -785420 -785420 - UDM-B-26UDM-B-26UDM-B-26UDM-B-26 A Black resinous material 2 NDNDNDND 0 100.0 B White sealant 30 NDNDNDND 0 100.0 C Yellow insulation 68 NDNDNDND 95 5.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

Christina Tiggemann Analyst

Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual

Effective July 28, 2026 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf

Job Number:

Client:

Client Project/P.O.:

Client Project Description:

Date Samples Received:

Analysis Type:

Turnaround:

Date Samples Analyzed:

785420-1 R & R Environmental

DFCM

UDOT MAIN OFFICE CEDAR CITY

September 11, 2026 EPA 600/R-93/116 - Short Report, Bulk Rush September 11, 2026

EUROFINS RESERVOIRS ENVIRONMENTAL, INC

NVLAP Lab Code 101896-0

AIHA LAP, LLC. LAB ID 101533

TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite

(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com

SUBMITTED BY INVOICE TO

RES Job #: 785420

CONTACT INFORMATION SERIES

ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES

CHEMISTRY LABORATORY

MICROBIOLOGY LABORATORY

**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**

Laboratory Analysis Instructions

(Sample ID's must be unique)

Company: R & R Environmental Company: R & R Environmental

Address: 47 West 9000 South #2 Address: 47 West 9000 South #2

Sandy, UT 84070 Sandy, UT 84070

Project Number and/or P.O. #: DFCM Project Zip Code:

Project Description/Location: UDOT MAIN OFFICE CEDAR CITY

Contact: Craig Ford -1 PLM Rush *NO VERBALS* Phone: (801) 673-7488

Fax:

Cell: (801) 673-7488

Final Data Deliverable Email Address:

craigford2011@gmail.com (+ 4 ADDNL. CONTACTS)

PLM / PCM / TEM / NYS DTL RUSH PRIORITY STANDARD Air = A Bulk = B

Dust = D Food = F

Paint = P Soil = S

Dust RUSH PRIORITY STANDARD

*PRIOR NOTICE REQUIRED FOR SAME DAY TAT

Surface = SU Swab = SW

Tape = T Wipe = W

Metals RUSH PRIORITY STANDARD Drinking Water = DW

Waste Water = WW

Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**

Viable Analysis** PRIORITY STANDARD

**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH

Medical Device Analysis RUSH STANDARD

Mold Analysis RUSH PRIORITY STANDARD

Special Instructions:

1 UDM-B-26 X B 09/09/26 00:00

P L

M

P L

M S h o rt R ep o rt (E

PA

/6

/R

-9 3/

6)

T E

M

P C

M

N Y

S

D U

S T

M E

TA

L

S

O R

G A

N

IC

S

V

IA

B L

E S

M E

D

IC

A L

M O

L D

S am pl e

V ol um e

(L

A re a

S am pl e

Te m pe ra tu re

C

Le ng th (o r A liq uo ts

) x W id th

(o r A re a/

A liq uo t)

M at rix C od e of

C on ta in er s

D at e C ol le ct ed m m

/d d/ yy

T im e C ol le ct ed hh :m m

Eurofins Reservoirs Environmental, Inc establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.

Eurofins Reservoirs Environmental, Inc will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET30. Failure to comply with payment terms may result in a 18% APR finance charge.

Relinquished By:

Craig Ford Date/Time: 09/10/2026 13:04:53 Sample Condition: Acceptable

Received By:

Jessica Strait Date/Time: 09/11/2026 10:54:42 Carrier: Fed-Ex

Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual

Effective July 28, 2026 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf

(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com

Client Sample ID Sample Note Quantity Sampler(s)

UDM-B-26 TSI LAGGING

R & R Environmental Sample Notes

RES #: 785420

Project Number and/or P.O. #: DFCM

Client Sample ID Sample Location

UDM-B-26 BOILER ROOM

R & R Environmental Sample Locations

RES #: 785420

Project Number and/or P.O. #: DFCM

Appendix C

Photo Log

PHOTO 1: Utah Department of Transportation, R & R Environmental, Inc.

47 West 9000 South, Suite #2, Sandy, Utah 84070

(801) 352-2380 • Fax: (801) 352-2381

SITE PHOTOGRAPHS

LIMITED ASBESTOS SURVEY AND ASSESSMENT

UTAH DEPARTMENT OF TRANSPORTATION

CEDAR CITY ADMINISTRATION BUILDING

PROJECT NO:

DESIGNED BY:

SCALE: REVIEWED BY:

DRAWN BY:

DATE:

FILE:

Appendix D

Floor Plan

N

UDOT ADMIN BLDG

1470 N. AIRPORT RD.

CEDAR CITY, UT 84720

SEPTEMBER 2026

MAIN FLOOR

ASBESTOS FLOORPLAN

= ASBESTOS SAMPLE NUMBER & LOCATION##

Maintenance

IT

Server

Storage

12 13

03 04

212022

18 19

Appendix E

State of Utah Certifications

Utah Asbestos Certification

State of Utah

SPENCER J. COX

Governor

DEIDRE HENDERSON

l)e,1ten<mt Governor

February 27, 2026

Trevor Thacker R&R Environmental

Depat1ment of Environmental Quality

Tim Dovis Executive Director

DIVISION OF AIR QUALITY

Bryce C. Bird

Director

47 West 9000 South, Suite 2 Sandy, UT 84070

Dear Mr. Thacker:

Re: Utah Asbestos Program Individual Certification Card

Trevor Thacker

ASB-8872

Inspector (8' 01/20/2027)

~r

DAQA-001-26

The Utah Division of Air Quality (DAQ) has reviewed your Utah Asbestos Program Certification

Application for Individuals and we are pleased to inform you that your application has been approved. Your new asbestos program individual certification card is enclosed with this letter and this card is the sole method of individual certification documentation that you will receive from the DAQ.

Please check the information on your asbestos program certification card carefully. Please confirm that the photograph, name, and certification discipline(s) are correct. Also, please remember to keep your current asbestos program certification card with you at all times when you are performing regulated asbestos work activities.

Please contact Barbara Perkins at (80 I) 536-0221 or at bperkins@utah.gov if you have any questions regarding this letter or the enclosed asbestos program certification card.

Sincerely, Leonard Wright (Feb'25.2026 13·10:01 MST)

Leonard Wright, Manager Air Toxics, Lead-Based Paint, and Asbestos Section

LW;BP:rh

195 No11h 1950 West• Suh Lnko City, UT Mailing Address; P.O. Oox 144820 • Sul1 Luko City, UT 84114-4820

'1'1:lcphonc {801) 536f4000 • Pnx (801) 536~4099 • T,D.D. 800 346-3128 1111vi11.tleq.11tqh,1:ov l'rintcd on IOO¾ recycled pai1cr

Utah Asbestos Certification

SPENCER J. COX

Governor

DETORE HENDERSON

Lieutenant Governor

February 27, 2026

Jamison Moss R&R Environmental

Depa1tment of Environmental Quality

Tim Davis fa:ec11tive Direc/01·

DIVISION OF AIR QUALITY

Bryce C. Bird

Director

47 West 9000 South, Suite 2 Sandy, UT 84070

Dear Mr. Moss:

Re: Utah Asbestos Program Individual Certification Card

Jamison Moss

ASB-6674

"'" Inspector (Eitp:" 02/20/2027)

Project oeMner'(Exp. 01/12/2027) it V .

4U~hD-~~fA.'Q 1· Director, ta IvIs1on o ir ua 1ty

DAQA-001-26

The Utah Division of Air Quality (DAQ) has reviewed your Utah Asbestos Program Certification Application for Individuals and we are pleased to inform you that your application has been approved. Your new asbestos program individual certification card is enclosed with this letter and this card is the sole method of individual certification documentation that you will receive from the DAQ.

Please check the information on your asbestos program certification card carefully. Please confirm that the photograph, name, and certification discipline(s) are correct. Also, please remember to keep your current asbestos program certification card with you at all times when you are performing regulated asbestos work activities.

Please contact Barbara Perkins at (801) 536-0221 or at bperkins@utah.gov if you have any questions regarding this letter or the enclosed asbestos program certification card.

Sincerely, Leonard Wrlgll (Feht2026 09:17:31 Msn

Leonard Wright, Manager Air Toxics, Lead-Based Paint, and Asbestos Section

LW:BP:rh

195 North 1950 Wes1 • Sah Lakll Chy, UT Mailing Address: P.O. Box 144820 • Sall Lake City, UT 84114-4820

Telephone (80 I) 536-4000 • flax (80 I) 536-4099 • T.D.D. 800 346-3128 www.1l1111,111ul,,Mo11 l'rinlcd on 100¼ recycled p11pcr

Utah Lead-Based Paint Certification

SPENCER J. COX

Go,·tmor

DEIDRE HENDERSON

litutenant Gol'limor

February 11, 2025

Steve Smith

Department of Environmental Quality

Kimberly D. Shelley Exec11tfre Director

DIVISION OF AIR QUALITY

Bryce C Bird

Director

R&R Environmental, Inc.

4 7 West 9000 South, #2 Sandy, UT 84070

Dear Mr. Smith:

Re: Utah Lead-Based Paint Program Individual Certification Card

Inspector l Risk Aue

-4~;_·~

Director, Utah D1v1sion of Air Quality

DAQA-002-25

The Utah Division of Air Quality (DAQ) has reviewed your Utah Lead-Based Paint (LBP)

Program Certification Application for Individuals and we are pleased to inform you that your application has been approved. Your new LBP program individual certification card is enclosed with this letter and this card is the sole method of individual certification documentation that you will receive from the DAQ.

Please check the information on your LBP program certification card carefully. Please confirm that the photograph, name, and certification discipline(s) are correct. Also, please remember to keep your current LBP program certification card with you at all times when you are performing regulated LBP work activities.

Please contact Barbara Perkins at (80 l) 536-0221 or at bperkins@utah.gov if you have any questions regarding this letter or the enclosed LBP program certification card.

Sincerely, ~ Sl1J~ Leonard Wright (Feb 7, 2025 12:09 MST)

Leonard Wright, Manager Air Toxics, Lead-Based Paint, and Asbestos Section

LW:BP:lr

195 Nonh 1950 Wes,, 4~' Hoor • Sall Lake City, Ur Mailing Addrm l' 0 llo"< 144820 • Suh Lnl.c Cny. UT 84114-1820

'I elephone (80 I) 536-4000 • l·a"< (801) 536-4099 ·TDD (80 I) 536-1-11-1 ~• u ,, di:tJ mnh gm•

P11111cd on I00~. 1ccycled papc, LIMITED LEAD-BASED PAINT INSPECTION

UTAH DEPARTMENT OF TRANSPORTATION

CEDAR CITY ADMINISTRATION BUILDING

Utah Department of Government Operations Division of Facilities, Construction and Management (DFCM)

Taylorsville State Office Building, 3rd Floor 4315 South 2700 West

47 West 9000 South, Suite #2

Sandy, Utah 84070

LIMITED LEAD-BASED PAINT INSPECTION

TABLE OF CONTENTS

TITLE PAGE

1.0 Introduction

2.0 Building Description

3.0 Lead-based Paint Definition

4.0 Procedures

4.1 Paint Sampling Methods

4.2 XRF Calibration

4.3 Field Documentation

5.0 Findings

6.0 Results and Recommendation

8.0 Limitations and Exclusion of Warranty

Appendices

A. Data Tables Table 1 – Building Component with Lead Levels at 0.1 mg/cm2 and above Table 2 – Building Component with Lead Levels at below 0.1 mg/cm2 B. Photograph Log

Utah Department of Transportation Limited Lead-Based Paint Inspection Cedar City Administration Building Page 1

Limited Lead-Based Paint Inspection

1.0 INTRODUCTION

During the month of September 2026, a limited lead-based paint (LBP) survey was conducted for the Utah Department of Transportation, Cedar City Administration Building.

The purpose of the survey was to identify lead surrounding HVAC components that are going to be replaced. Measurements for lead in paint were made using a SciApps X550 X-ray Fluorescence (XRF) Spectrum Analyzer. No chip sampling or Administration analysis was performed for confirmation of XRF measurements.

The survey work was overseen by David C. Roskelley with R & R Environmental, Inc. in Sandy, Utah. Mr. Roskelley has completed Lead Inspector Training through the University of Utah, Rocky Mountain Center for Occupational and Environmental Health (RMCOEH), an EPA-sponsored Regional Lead Training Center, and is certified by the State of Utah, Division of Environmental Quality, as a Lead Inspector.

The U.S. Department of housing and Urban Development (HUD) Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in housing (HUD Guidelines), Chapter7: Lead-Based Paint Inspection, 1997 Revision, was generally followed for this survey, with modifications appropriate for a non-residential building.

The following accredited and certified inspector oversaw the collection of the samples:

September 14, 2026 David C. Roskelley, MSPH, CIH, CSP Date Lead-Based Paint Inspector Certification Number: PB-1041

The following accredited and certified inspector oversaw the inspection, made assessment, and reviewed the report:

September 14, 2026 David C. Roskelley, MSPH, CIH, CSP Date Lead-Based Paint Inspector Certification Number: PB-1041

Cedar City Administration Building Page 2

2.0 BUILDING DESCRIPTION

Building Identification

Building Name ....................................... UDOT, Cedar City Administration Building Address .......... 1470 North Airport Road, Cedar City, Utah 84720

Building Construction

Building Construction Date Building Type .................................................................. Mechanical Space Building Total Sq. Ft .......................................... (Affected Area) ~1,500 ft2 Structural System ....................................................... Structural Steel, Stone Exterior Wall Construction .................................................................. Brick Floor Deck Construction .............................................. Reinforced Concrete Roof Construction .................................................................................... NA Floors Above Grade ................................................................................. NA Floors Below Grade ................................................................................. NA

Interior Finishes

Floors ............................................................................................. Concrete Walls ........................................ Wallboard System, Brick, Corrugated Steel Attic .......................................................................................................... NA Crawl space .............................................................................................. NA

Building Mechanical

Heating Plant ............................................................................... Central Air Main Heating Distribution .......................................................... Central Air Cooling Plant .............................................................................. Central Air Main A / C Distribution .............................................................. Central Air

Cedar City Administration Building Page 3

3.0 LEAD-BASED PAINT DEFINITIONS

HUD defines “lead-based paint” as any coating that has a lead concentration of 1.0 milligram of lead per square centimeter (1.0 mg/cm2) or greater, or if the lead concentration is greater than 0.5% by weight. The Consumer Product Safety Commission (CPSC) currently considers paint to be lead-containing if the concentration of lead exceeds 600 ppm (0.06% by weight). In 1978, the CPSC banned the sale of lead-based paint to consumers, and banned its application in areas where consumers have direct access to painted surfaces. Both the CPSC and HUD definitions of lead-containing paint are aimed at protecting the general population from exposure to lead in the residential setting.

By contrast, the mission of the Occupational Safety and Health Administration (OSHA) with respect to lead-containing paint, is to protect workers during construction activities that may generate elevated airborne lead concentrations. OSHA states that construction work (including renovation, maintenance, and demolition) carried-out on structures coated with paint have lead concentrations lower than the HUD or CPSC can still result in airborne lead concentrations in excess of regulatory limits. For this reason, OSHA has not defined lead-containing paint, but states that paint having any measurable level of lead may pose a substantial exposure hazard during construction work, depending upon the work performed.

4.0 PROCEDURES

4.1 Paint Sampling Methodologies

Direct measurements of lead in paint were made using a SciApps X550 X-ray Fluorescence (XRF) Spectrum Analyzer. The SciApps X550 X-ray Fluorescence (XRF) Spectrum Analyzer non-destructively measures lead concentrations of painted surfaces, regardless of the number of layers present. These instruments were developed specifically for addressing lead-based paint issues in housing and their use in identifying potential exposure hazards for renovation or construction work must be augmented by selective collection and analysis of physical paint chip samples.

The newer XRF instruments are capable of identifying lead in paint at concentrations of about 0.01 milligram per square centimeter (mg/cm2) or greater. When lead concentrations are lower than this, the instruments are not capable of making accurate, reliable measurements, and the reported lead concentration may underestimate or overestimate the actual lead concentration in the paint. Therefore, an XRF readings of 0.01 mg/cm2 or greater may be considered lead-containing from an OSHA perspective, and any readings of 0.0mg/cm2 or less should be confirmed by the collection and Administration analysis of paint chip samples, or assumed to be positive for lead.

Where paint chip samples are necessary, samples are collected according to the protocol specified in the HUD Guidelines. The samples are then submitted to a Administration recognized under the EPA’s National Lead Administration Accreditation Program (NLLAP) for analysis by flame atomic absorption spectrophotometry according to American Society of Testing and Materials (ASTM) method ASTM E 1645.

Cedar City Administration Building Page 4

4.2 XRF Calibration

Before beginning the testing and after the testing was completed, the internal calibration of the LPA-1 was checked by taking two consecutive measurements on a National Institute for Standards and Technology (NIST) standard with a known concentration of lead. Three more readings were taken on a lead-free wood block. These calibration checks are reported within the XRF data tables found in Appendix A of this report and are maintained in a file at R & R Environmental, Inc. to detect changes in instrument performance over time.

4.3 Lead Paint Inspection Data Tables

The XRF instrument generates a unique set of data tables for each inspection and can be exported into Microsoft Excel Spreadsheet format .xls. The Sequential Report lists the measurements made throughout the property in sequential order, from the first measurement to the last. The Data table is maintained in a file at R & R Environmental, Inc.

5.0 FINDINGS

The XRF instrument indicated that lead is not present of some of the interior building surfaces. If it were, this surface would be listed in Table 1 “positive” building components (Measurements of 0.01 mg/cm2 and above) in Appendix A of this report.

If lead was detected in some of the building’s painted surfaces, the OSHA Lead in Construction Standard (29 CFR 1926.62) will apply to any construction work (including renovation and demolition) that may disturb those surfaces. The standard requires, among other things, the following:

• Initial training on the hazards of lead exposure, proper work practices, respiratory protection, and other topics;

• An initial exposure assessment, by air monitoring, to determine the lead exposure assessment, until sample analysis indicates exposures below the Permissible Exposure Limit;

• Hand washing facilities, designated clean change areas, and designated eating areas.

In addition to the above considerations, the presence of lead in demolition debris has the potential to impose limitations on where and how the debris may be disposed. The Resource Conservation and Recovery Act (RCRA), Subtitles C and D, require that the waste must be analyzed to determine the amount of leachable lead present. The type of test to be performed on the waste is the Toxicity Characteristic Leaching Procedure (TCLP) for lead, and the results of this test will determine whether the material must be handled and disposed of as hazardous waste. For structures containing large amounts of lead-containing paint, significant potential for failing the TCLP exists.

Cedar City Administration Building Page 5

6.0 RESULTS AND RECOMMENDATIONS

No lead-based paint was detected during this limited survey.