6-08. Project Plans (1 Sheet).pdf

PDF 757 KB Posted

Attached to
Manatawny Green Surface Replacement
Solicitation number
US.202742
Issued by
Montgomery County, Pennsylvania

About this file

This is a site plan document for the Manatawny Green Surface Replacement project, prepared by Remington & Vernick Engineers for the Borough of Pottstown in Montgomery County, Pennsylvania. The project involves replacing the existing outdoor surface of a mini-golf course located at 71 West High Street in Pottstown. The site plan details the complete reconstruction of the mini-golf course, including removal of the existing surface, preparation of the subsurface, and installation of new outdoor carpet surfaces in various colors (short green, long green, and white/tan) for each mini-golf hole and the practice green.

The document provides comprehensive construction notes, including erosion and sediment control requirements, demolition procedures, ADA accessibility guidelines, and specific PennDOT construction standards. The contractor will be responsible for providing all equipment, labor, and materials, with strict requirements for site safety, cleanliness, and restoration. The project involves careful surface preparation, surface removal, and installation of new surfacing materials, with specific attention to maintaining pedestrian access, protecting existing infrastructure, and ensuring proper environmental controls during the construction process.

View the file

Other files

File Type Posted
4-02. Notice to Bidders.pdf PDF
7-07. Technical Specifications.pdf PDF
2-04. Information for Bidders.pdf PDF
8-01. Signed Cover Sheet.pdf PDF
1-03. Proposal Section.pdf PDF
5-06. General Conditions.pdf PDF
3-05. Wage Rate Determination.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SI

TE

P

LA

N( IN FEET )

GRAPHIC SCALE

1 inch = ft.

12 12

EXISTING CONDITIONS & SURVEY NOTES

1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS

AND EXISTING CONDITIONS IN THE FIELD. ANY ERRORS OR DISCREPANCIES SHALL BE

BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY.

EROSION & SEDIMENT CONTROL (E&S) NOTES

1. THE CONTRACTOR SHALL INSTALL AND MAINTAIN ALL TEMPORARY E&S BEST MANAGEMENT

PRACTICES (BMPS) DURING THE CONSTRUCTION. TEMPORARY E&S BMPS SHALL INCLUDE

ANY DEPICTED ON THE PLANS AND THE FOLLOWING:

a. STORM INLET PROTECTION. INLET FILTER BAGS SHALL BE INSTALLED IN EACH EXISTING

AND PROPOSED STORM INLET RECEIVING RUNOFF FROM THE PROJECT AREA.

b. SEDIMENT BARRIERS. COMPOST FILTER SOCK, SILT FENCE OR OTHER SUITABLE

BARRIERS SHALL BE INSTALLED ON LEVEL GRADE DOWNSTREAM FROM DISTURBED

AREAS AND STOCKPILES.

c. CONCRETE WASHOUT. FOR ANY PROJECT WHERE CONCRETE WILL BE POURED ON SITE, A SUITABLE WASHOUT FACILITY MUST BE PROVIDED.

d. PUMPED WATER FILTER BAG. A PUMPED WATER FILTER BAG SHALL BE USED TO FILTER

WATER PUMPED FROM EXCAVATED AREAS (DEWATERING), SEDIMENT STORAGE AREAS

OF SEDIMENT BASINS AND SEDIMENT TRAPS.

2. E&S BMPS SHALL BE INSPECTED AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL

PREVENTATIVE AND REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR,

REPLACEMENT, REGRADING, RESEEDING, REMULCHING AND RENETTING MUST BE

PERFORMED IMMEDIATELY. IF THE E&S BMPS FAIL TO PERFORM AS EXPECTED,

REPLACEMENT BMPS OR MODIFICATIONS OF THOSE INSTALLED WILL BE REQUIRED.

3. UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND PERMANENT

STABILIZATION OF ALL DISTURBED AREAS, THE CONTRACTOR SHALL REMOVE ALL

TEMPORARY E&S BMPS. PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM,

PERENNIAL 70% VEGETATIVE COVER OR OTHER PERMANENT NON-VEGETATIVE COVER WITH

A DENSITY SUFFICIENT TO RESIST ACCELERATED EROSION.

DEMOLITION NOTES

1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL, TRANSPORTATION, AND PROPER

DISPOSAL OF ALL DEMOLISHED MATERIALS. DEMOLISHED MATERIALS MUST BE MOVED

OFFSITE TO AN APPROVED FACILITY.

2. THE CONTRACTOR SHALL PERFORM DEMOLITION WORK AS NECESSARY TO FACILITATE THE

PROPOSED WORK, INCLUDING ANY DEMOLITION WORK NOT SPECIFICALLY INDICATED ON

THE PLANS.

GENERAL CONSTRUCTION NOTES

1. THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, LABOR AND MATERIALS.

2. AS THE AREAS ARE FOR THE EXACT SHAPE THE CONTRACTOR WILL BE REQUIRED TO USE AS

MANY ROLLS OF OUTDOOR SURFACING REQUIRED TO COMPLETE THE JOB.

3. ALL PEDESTRIAN ACCESS TO SIDEWALKS AND STREETS, INCLUDING CROSSWALKS, CURB

RAMPS, PARKING AND OTHER COMPONENTS OF PEDESTRIAN ACCESS ARE TO BE IN

ACCORDANCE WITH AMERICANS WITH DISABILITIES ACT (ADA) & ARCHITECTURAL BARRIERS

ACT (ABA) ACCESSIBILITY GUIDELINES AND THE CURRENT PUBLIC RIGHTS-OF-WAY

GUIDELINES PROPOSED BY THE ARCHITECTURAL AND TRANSPORTATION BARRIERS

COMPLIANCE BOARD (ACCESS BOARD).

2. ALL CONSTRUCTION SPECIFICATIONS AND DETAILS NOT SHOWN SHALL BE IN ACCORDANCE

WITH PENNDOT STANDARDS AS DETAILED IN THE LATEST REVISIONS OF THE FOLLOWING:

a. PUBLICATION 35 (BULLETIN 15) “QUALIFIED PRODUCTS LIST FOR CONSTRUCTION”;

b. PUBLICATION 408/2020 ”SPECIFICATIONS”;

c. PUBLICATION 72M/2010 “STANDARDS FOR ROADWAY CONSTRUCTION”;

d. PUBLICATION 111 “TRAFFIC CONTROL - PAVEMENT MARKINGS AND SIGNING

STANDARDS”;

e. PUBLICATION 213 “TEMPORARY TRAFFIC CONTROL GUIDELINES”.

INCLUDING ALL APPLICABLE BASELINE DOCUMENT CHANGES AND APPENDICES. THESE

CONSTRUCTION SPECIFICATIONS AND DETAILS MAY BE PURCHASED THROUGH THE

PENNDOT SALES STORE AT:

P.O BOX 2028

HARRISBURG, PA 17105-2028

(TELEPHONE: 1-717-787-6746)

CONSTRUCTION SEQUENCE

THE CONSTRUCTION SEQUENCE FOR THE PROJECT WILL BE AS FOLLOWS:

1. REMOVE THE EXISTING OUTDOOR SURFACE FROM ALL LOCATIONS WITHIN THE PROJECT AS

WELL AS ANY ADHESIVES USED TO SECURE THE EXISTING SURFACES.

2. PREPARE THE NEWLY EXPOSED SUBSURFACE (CONCRETE) FOR THE INSTALLATION OF THE

NEW OUTDOOR SURFACES.

3. INSTALL THE NEW; SHORT GREEN, LONG GREEN AND WHITE/TAN OUTDOOR CARPET

SURFACES FOR EACH MINI-GOLF HOLE, AND PRACTICE GREEN.

CONTRACT NOTES

3. THE CONTRACTOR SHALL MAKE A PRE-CONSTRUCTION VIDEO OF THE PROJECT AREA BEFORE

BEGINNING ANY CONSTRUCTION ACTIVITIES.

4. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT ALL EXISTING CONCRETE CURB AND

SIDEWALK AREAS NOT SHOWN TO BE REMOVED OR REPLACED. THE CONTRACTOR WILL BE

RESPONSIBLE FOR COMPLETE REMOVAL AND REPLACEMENT OF ANY DAMAGED CURB OR

SIDEWALK NOT DOCUMENTED PRIOR TO THE START OF CONSTRUCTION AT NO ADDITIONAL

COST TO THE OWNER.

5. THE CONTRACTOR SHALL COORDINATE THEIR WORK WITH OTHER PRIME CONTRACTORS FOR

THIS PROJECT, IF APPLICABLE. IN ADDITION, THE CONTRACTOR SHALL COORDINATE THEIR

WORK WITH PRIME CONTRACTORS ON OTHER PROJECTS UNDER CONSTRUCTION NEAR THE

PROJECT AREA. ANY COORDINATION ISSUES SHALL BE BROUGHT TO THE ATTENTION OF THE

ENGINEER IMMEDIATELY. THERE WILL NOT BE ANY SEPARATE PAYMENT FOR THIS

COORDINATION, BUT THE COST SHOULD BE INCLUDED IN THE VARIOUS ITEMS OF THE

PROPOSAL.

6. SEPARATE PAYMENT WILL NOT BE MADE FOR SAWCUTTING OF ANY KIND, BUT THE COST

SHALL BE INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.

7. SEPARATE PAYMENT WILL NOT BE MADE FOR THE REMOVAL, TEMPORARY STORAGE AND

REINSTALLATION OF EXISTING SIGNAGE ALONG THE PROJECT AREA, BUT THE COST SHALL BE

INCLUDED IN THE VARIOUS ITEMS OF THE PROPOSAL.

8. CONTRACTOR SHALL RESTORE ALL EXISTING FEATURES DISTURBED DURING CONSTRUCTION

(I.E. MAILBOXES, IRRIGATION SYSTEMS, LANDSCAPING, ETC.). ALL COSTS SHALL BE INCLUDED

IN THE PRICE BID FOR SITE CLEARING.

SITE SAFETY, CLEANLINESS & RESTORATION NOTES

1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY ON THE PROJECT SITE AND FOR

FOLLOWING ALL OSHA AND LOCAL SAFETY STANDARDS.

2. THE CONTRACTOR SHALL ENSURE THAT THE SITE IS SECURE AT THE END OF EACH WORKDAY.

ALL EQUIPMENT AND MATERIALS SHOULD BE STORED NEATLY AND SECURELY. EXCAVATED

AREAS SHALL BE BACKFILLED OR SECURED TO PREVENT ANY FALL HAZARD.

3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING PAVED SURFACES, INCLUDING

SIDEWALKS, FREE AND CLEAR OF SEDIMENT AND IN A BROOM SWEPT CONDITION WHEN

OPEN TO PUBLIC USE. AT A MINIMUM, THE CONTRACTOR SHALL CLEAN PAVED SURFACES

AT THE END OF EACH WORKDAY AND WHEN DIRECTED BY THE ENGINEER.

4. THE ALL VEGETATED AREAS DISTRIBUTED DURING CONSTRUCTION SHALL BE TOPSOILED,

SEEDED, FERTILIZED AND COVERED WITH STRAW MULCH. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR WATERING AND/OR RE-SEEDING AS NECESSARY TO ENSURE VEGETATIVE

STABILIZATION.

5. ALL PAVED AND CONCRETE AREAS EXCAVATED OR DAMAGED DURING CONSTRUCTION

SHALL BE RESTORED TO EXISTING CONDITION AT LEAST EQUAL TO THAT WHICH EXISTED

PRIOR TO THE START OF CONSTRUCTION.

6. PRIOR TO FINAL PAYMENT, THE CONTRACTOR SHALL PERFORM FINAL CLEANING. FINAL

CLEANING SHALL INCLUDE REMOVAL AND PROPER DISPOSAL OF ALL EXCESS CONSTRUCTION

MATERIALS AND DEBRIS AS WELL AS CLEANING ALL PAVED SURFACES.

SITE INFORMATION

LOCATION:

1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS

AND EXISTING CONDITIONS IN THE FIELD. ANY ERRORS OR DISCREPANCIES SHALL BE

71 WEST HIGH STREET

POTTSTOWN, PA 19464

OWNER:

1. BOROUGH OF POTTSTOWN

SHEET No. :

CHECKED BY :DRAWN BY : DESIGN BY :

JOB No. :

DATE :

SCALE :

DMF DMF OMH

N o.

C H

K R

EV

IS

IO

N

D

AT

E

BY

Z:

\S ha re d\ 2_

O ld

Se rv er s\

Ki ng

O fP ru ss ia \C ad d\

D ra fti ng

\D ra fti ng

\P A\

Po tts to w n\

PM

PN

T0

M an at w an y

G re en S ur fa ce R ep la ce m en t\C

AD

\S ite P la n.

dw g

/9

/2

:3 1:

A

M

ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK

ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF

SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT

INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE

BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT

OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT

WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &

VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC

PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND

WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON

& VERNICK ENGINEERS AND AFFILIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &

VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,

DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR

R E S U L T I N G T H E R E F R O M .

of 2/28/2025

PMPNT033

AS NOTED

BO

R

O U

G H

O F

PO

TT

ST

O

W N

BO

R

O U

G H

O F

PO

TT

ST

O

W N

M O

N

TG

O M

ER

Y

C O

U N

TY

PE

N N

SY

LV

AN

IA

M

AN

AT

AW

N Y

G R

EE

N

S U

R

FA

C E

R

EP

LA

C

EM

EN

T

PROFESSIONAL ENGINEER LIC. No. PE-080447

OWEN M. HYNE

DATE:

REMINGTON

& VERNICK

ENGINEERS

(610) 940-1050, FAX (610) 940-1161

Croton Road Corporate Center 555 Croton Road, Suite 401 King of Prussia, PA 19406

WEB ADDRESS : RVE.COM

· Excellence Innovation Service·

09/15/2025

Sheets and Views
1 Site Plan

File details come from the government source that posted it. Updated .