3d OR Malheur RLP Amendment 5_ASR.pdf
PDF 1 MB Posted
- Solicitation number
- 57-41045-23-NR
About this file
This document is a lease amendment for a federal contract opportunity issued by the U.S. Department of Agriculture (USDA) to lease office and related space in Ontario, Oregon.
The key details are:
- The Government is seeking a minimum of 5,737 to a maximum of 6,024 ABOA square feet, yielding no more than 6,885 RSF of contiguous office and related space within the specified delineated area.
- The lease term is 20 years, with a 5-year firm term and Government termination rights after the firm term with 120 days' notice.
- The Agency Specific Requirements (ASRs) provide detailed space requirements, including private offices, open office, conference room, breakroom, and specialty spaces such as a laboratory and mud room.
- The Lessor is required to provide various security and physical access improvements as part of the Tenant Improvement costs.
- The Lessor must also provide the infrastructure to support 4 dual-port Level 2 electric vehicle charging stations.
- The offer due date is August 30, 2024 and the estimated lease award date is to be determined.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Except as provided herein, all terms and conditions in the solicitation remain unchanged and in full effect
II. ACKNOWLDEGEMENT OF AMENDMENT
I n l i eu o f o t h e r w r i t t e n m e t ho ds o f a ck n ow l e d g em e n t , t he o f f e ro r m ay c om p l e t e B l o ck 9 a n d 1 0 a nd r e t u r n t h i s am e n dm e n t t o t he a d d re ss i n B l o ck 5 .
9. NAME AND ADDRESS OF OFFEROR 10A. OFFEROR (Signature of person authorized to sign)
10B. NAME OF SIGNER
10C. TITLE OF SIGNATURE
10D. DATE
AUTHORIZED FOR LOCAL REPRODUCTION OPTIONAL FORM 309 (9-97)
Prescribed by GSA – FAR (48 CFR) 53.215-1(g)
AMENDMENT OF SOLICITATION
(Negotiated Procurements)
PAGE of PAGES
NOTICE: Of fero rs mus t acknowledge rece ip t o f th is amendment in wr i t i ng by the date and t ime spec i f ied for proposa l submiss ions or the dat e and t ime spec i f ied i n B lock 6 , wh icheve r i s la te r . IF YOUR ACKNOWLEDGEMENT IS NOT RECEIVED AT THE DESIGNATED LOCATION BY THE SPECIFIED DATE AND TIME, YOUR OFFER MAY BE REJECTED. I f by v i r t ue o f th is amendment you w ish to change your o f f e r , such change mus t make re f erence to the so l i c i ta t ion and th is amendment and be rece ived pr io r to the date and t ime spec i f ied i n B lock 6 .
I. AMENDMENT
1. SOLICITATION NUMBER 2. SOLICITATION DATE 3. AMENDMENT NUMBER 4. AMENDMENT DATE
57-41045-23-NR 12/19/2023 5 8/23/2024
5. ISSUED BY
6. DUE DATE
United States Department of Agriculture Real Property Lease Acquisition 1400 Independence Ave SE
Washington, DC 20250
THIS AMENDMENT DOES NOT CHANGE THE DATE BY WHICH
OFFERS ARE DUE UNLESS A DATE AND TIME IS INSERTED
BELOW
A. DATE B. TIME
Offers Due by August 30, 2024 5:00 PM Eastern
7. FOR INFORMATION CALL (No collect calls)
A. NAME B. TELEPHONE C. EMAIL ADDRESS
Korinna Garbis
AREA
CODE PHONE NUMBER
korinna.garbis@usda.gov 202 720-5297
8. DESCRIPTION OF AMENDMENT
REPLACE IN ITS ENTIRETY:
1.02 AMOUNT AND TYPE OF SPACE, LEASE TERM, AND OCCUPANCY DATE (OCT 2016)
A. The Government is seeking a minimum of 5,737 to a maximum of 6,024 of American National Standards Institute/Building Owners and Managers Association (ANSI/BOMA) square feet (SF), yielding no more than 6,885 Rentable Square Feet (RSF) of contiguous space within the Area of Consideration set forth below. See Section 2 of the Lease for Applicable ANSI/BOMA standards.
F. The lease term shall be 20 Years, 5 Years Firm, with Government termination rights, in whole or in parts, effective at any time after the Firm Term of the Lease by providing not less than 120 days’ prior written notice.
REPLACE IN ITS ENTIRETY: AGENCY SPECIFIC REQUIREMENTS (ASRs) EXHIBIT B
USDA AGENCY SPECIFIC REQUIREMENTS (ASRs) SOLICITATION PROVISIONS IN THE SOLICITATION PACKAGE, ‘EXHIBIT B USDA FORM ASR’S, SOLICITATION PROVISIONS (DATED 12/23) IS HEREBY DELETED IN ITS ENTIRETY AND REPLACED WITH THE FOLLOWING ‘EXHIBIT B AGENCY SPECIFIC REQUIREMENTS (ASRs) DATED AUGUST 23, 2024.
Except as provided herein, all terms and conditions in the solicitation remain unchanged and in full effect
II. ACKNOWLDEGEMENT OF AMENDMENT
I n l i eu o f o t h e r w r i t t e n m e t ho ds o f a ck n ow l e d g em e n t , t he o f f e ro r m ay c om p l e t e B l o ck 9 a n d 1 0 a nd r e t u r n t h i s am e n dm e n t t o t he a d d re ss i n B l o ck 5 .
9. NAME AND ADDRESS OF OFFEROR 10A. OFFEROR (Signature of person authorized to sign)
10B. NAME OF SIGNER
10C. TITLE OF SIGNATURE
10D. DATE
AUTHORIZED FOR LOCAL REPRODUCTION OPTIONAL FORM 309 (9-97)
Prescribed by GSA – FAR (48 CFR) 53.215-1(g)
------------------------------------------------------------------- END OF RLP CHANGES --------------------------------------------------------------------
LEASE NO. 57-41045-23-NR
AGENCY SPECIFIC REQUIREMENTS (NOV 2023)
PAGE 1 LESSOR: ______ GOVERNMENT: ________
EXHIBIT B
USDA Agency Specific Requirements
Lease Number: 57-41045-23-NR Ontario, OR
The Agency Specific Requirements (ASRs) do not reduce the minimum requirements contained within the Lease. These ASRs provides specific agency requirements, which may be complementary, more specific, or more stringent than those of the Lease minimum requirements. To the extent the contents of these ASRs conflict with the contents of the Lease, the more stringent requirement shall apply.
A. ROOM SCHEDULE
The following spaces in these approximate sizes shall be provided by the Lessor.
*NOTE: NRCS staff numbers might reflect non-USDA partners where NRCS provides workspace to partners through separate agreement.
TOTAL USDA PERSONNEL: 8 13 21
FSA NRCS
SPACE TYPE SQUARE
FOOTAGE
NEEDED
7 PRIVATE OFFICES (120 sf each +/-) 480 360 840
OPEN OFFICE AND CIRCULATION AREA (18 work stations/1 touch-down stations)
414 1014 3067
CONFERENCE ROOM 114 186 300
BREAK ROOM 57 93 150
RECEPTION AREA 57 93 150
MAIL/COPY AREA 57 93 150
ADP ROOM 38 62 100
CONSULTATION/HUDDLE ROOM 30 50 80
File Room 114 186 300
MUD ROOM 0 150 150
LABORATORY 0 300 300
NRCS Soil Lab Storage 0 150 150
MINIMUM ABOA (Space Used by USDA Only): 5737
MAXIMUM ABOA (Space Used by USDA Only): 6024
MAXIMUM RSF (Rentable Square Footage includes common areas such as bathrooms, utility rooms, vestibules, and other space shared with non-USDA tenants):
Government Vehicle Reserved Parking Needed: 9
Employee/Customer Unreserved Parking Needed: 45
PAGE 2 LESSOR: ______ GOVERNMENT: ________
B. ROOM DESCRIPTIONS
Lobby/Reception Area – The lobby area is designed for customers to enter, check in, and wait to be seen by USDA staff.
1. Electrical outlets according to local code.
2. Flooring, wall coverings, and window coverings according to Lease.
3. See Physical Security requirements below for additional information.
Design Examples:
Private Offices- Private offices shall be designed to accommodate (1) one individual seated at a desk, with space for (2) two additional guests. These spaces are to be utilized by individuals who require acoustic and visual privacy for meetings and phone calls or tele/video conferencing. Interior glass window with blinds to provide visibility to the open office and allow daylight to penetrate through.
1. Sound Transmission Class rating as specified in Lease.
2. Greater of three (3) double electrical outlets or local code.
3. Two (2) telecommunication outlet.
4. Three (3) coat hooks on the wall next to the door.
5. Flooring, wall coverings, and window coverings according to Lease.
Design Example:
PAGE 3 LESSOR: ______ GOVERNMENT: ________
Consult Room – Consult rooms shall be designed to seat up to 4 individuals for hosting small meetings, phone calls, tele/video conferencing, or for individual working. Locate adjacent to workstation clusters and in close proximity to enclosed offices. When possible, provide access to natural daylight.
Interior glass window with blinds to provide visibility to the open office and allow daylight to penetrate through. Provide film at seated height for partial privacy.
2. Greater of five (5) double electrical outlets or local code.
3. Two (2) telecommunication outlet.
4. Three (3) coat hooks on the wall next to the door.
5. Flooring, wall coverings, and window coverings according to Lease.
Conference Room - Meeting rooms for 10-12 people for large meetings, tele/video-conferencing, as well as presentations. Locate centrally within the office and adjacent to the reception/service desk in order to provide immediate access for invited guests. Ideally, locate close to the break area for convenience for invited guests. Consider locating doors off of the open office area for acoustic privacy. Provide access to daylight when possible.
2. Greater of five (5) double electrical outlets or local code.
3. One (1) or Two (2) telecommunication floor boxes.
4. Lessor to provide data jack and audio-visual (A/V) connection for installation of a wall mounted television to use for presentations. Lessor is responsible for maintenance of connections/wiring and data jack, but television is the property of USDA and is to be installed and maintained by USDA.
5. Six (6) coat hooks on the wall next to the door.
6. Flooring, wall coverings, and window coverings according to Lease.
PAGE 4 LESSOR: ______ GOVERNMENT: ________
Break Room - An enclosed or semi-enclosed space to serve as a destination for refreshment. The space is provisioned to support food preparation and storage, coffee machines and recycle bins.
Depending on size of office this may be an area for socialization, so seating area should be provided.
Locate adjacent to conference room. Some enclosure is necessary to reduce transmission of noise and smells into the workplace.
2. Greater of four (4) double electrical outlets or local code, in addition to the outlets required for refrigerator/freezer and microwave. Outlets provided at counter per local code.
3. Six (6) coat hooks on the wall next to the door.
4. Flooring, wall coverings, and window coverings according to Lease.
5. Lessor to provide and maintain, as part of operations and maintenance of the Premises, a breakroom refrigerator with freezer (at least 18 cu ft in size) and countertop microwave oven.
The Lessor shall retain ownership of these items, and associated costs shall be included in Operating Expenses on the Form 1217.
6. Minimum of ten (10) feet of counter with base and overhead cabinets and double compartment sink.
PAGE 5 LESSOR: ______ GOVERNMENT: ________
Secure Storage – This room is for equipment or other content that needs to be securely stored, but easily accessible within the office. Size and type of storage units will vary depending on content requirements.
1. Room shall not be accessible through the ceiling to prevent “up and over” access. Utilize slab-to-slab walls or installation of steel mesh to prevent intrusion.
2. Solid core door with door hinges installed inside the room. No windows or other openings.
3. Fire extinguisher required.
4. Sound Transmission Class rating as specified in Lease.
5. Greater of three (3) double electrical outlets or local code.
6. Flooring and wall coverings according to Lease.
Open Office - A standard space for an individual to accomplish focused solo work and short-term collaborative work who spend most of their time at their desk. Individual workstations are provided in combination with easily accessible meeting spaces for group work and focus booths for concentration or private conversation. Place near floor perimeter to maximize access to natural light.
Generally, this is open space where systems (cubicle) furniture will be installed by USDA. Lessor must ensure electrical and data connections are available to hard wire the installed furniture, and Lessor is responsible for providing an electrician to undertake or assist with the furniture installation.
Data and electrical can be provided via ceiling drops or wall connections.
PAGE 6 LESSOR: ______ GOVERNMENT: ________
Mud Room - The Mud Room includes a shower area of approximately 120sf for cleaning and washing field equipment. The room should provide complete visual and acoustic privacy and shall be located away from open offices areas. Recommend locating adjacent to a point of entry, to limit path of travel through office. Locate near lavatories or existing plumbing.
2. Electrical outlets per local code.
3. Three (3) coat hooks on the wall next to the door.
4. Flooring, wall coverings, and window coverings according to Lease.
C. REQUIRED FEATURES NOT INCLUDED IN SHELL COSTS: For all of these items, purchase and installation should be included in the Lessor’s Tenant Improvement costs and ongoing maintenance should be an Operating Cost included on GSA Form 1217.
1. Lessor to install and maintain all Telecommunication Requirements (development of ADP
Room, CAT wiring, etc.) as outline in Lease Exhibit G.
2. If the US Postal Service will not deliver and pick up mail from each USDA agency inside the Premises, then the Lessor is required to provide and maintain separate mailboxes for each USDA agency in the Premises. The mailboxes must be lockable and acceptable to both USDA and USPS. The incoming mailboxes must be of sufficient size to accept a single package of 9” wide x 11 ½” deep x 12” high, or a separate common oversized mailbox of that minimum size must be provided. A separate outgoing mailbox capable of holding outgoing parcel of a minimum of 9” wide x 11 ½” deep x 12” high must also be provided by Lessor. Location and design must be approved by LCO or designated representative.
3. Lessor to install and maintain a through-the-wall locking depository drop box. Drop box should be secure and provide the ability for receipt of documents from exterior of building without entering interior areas of the building. Location and design must be approved by LCO or designated representative.
4. Lessor to provide and maintain signage as outlined in USDA Facility Signage Guide as furnished by the Government.
a. The monument sign must be such that the sign is visible from both directions of traffic.
b. Sign locations and design must be approved by LCO or designated representative.
PAGE 7 LESSOR: ______ GOVERNMENT: ________
b. Should the location of the leased Premises not be evident to customers parking in the parking lot, the Lessor shall install and maintain directional or wayfinding signage from the parking area to the Premises.
5. Lessor to Install and maintain fire extinguishers, smoke detectors, carbon monoxide detectors, and automated external defibrillator (AED).
D. REQUIRED FEATURES TO BE INCLUDED IN SHELL COSTS: Lessor shall include the costs associated with these features in Shell Rent.
1. The leased Premises must comply with accessibility requirements set forth in Section 3.15 of
Lease at the time of lease commencement. Offeror must agree to correct the following accessibility related deficiencies found in previously completed ABAAS review:
2. Secured Government Parking: The lessor is to provide a secure fenced parking area that will allow pull through parking to secure government property. The fenced area should be fully enclosed with a 6’ chain-link fence, totaling 6,400 SF to accommodate approximately 9 government vehicles, 5 UTV’s, 3 trailers and equipment. The fenced parking area should also include space to accommodate EVSE stations (see Section F below). There should be two gates (located on opposite sides) at least 20 ft. wide, unobstructed opening is required to allow vehicles to pull though the secured parking area. The gates will include cypher locks, a pedestrian 3’ width walk gate, and should include an exit emergency panic bar.
E. PHYSICAL SECURITY REQUIREMENTS
In addition to the specifications set forth in Section 7.01 of the Lease, the Lessor is required to install the necessary improvements to meet the below requirements. Costs associated with the purchase and installation of improvements are considered Tenant Improvements (TI) and should be reflected in the Tenant Improvements Costs Summary (TICS) table. Costs to operate and maintain these improvements are considered operating expenses and should be reflected in the Lessor’s Annual Cost Statement (GSA Form 1217).
1. Hardened Customer Service Counter: A Hardened Customer Service Counter or Service
Window shall be installed to separate the public lobby area from employee workspace. It shall be designed in a way that customers cannot access USDA space (on the other side of the counter) unless permitted entry through a locked door. This counter must be a hardened barrier that requires employees to enter through a locked door to enter from the public side of the counter into USDA employee space. The door must have a lock and remain secured at all times. The counter shall be 42” to 48’’ high and may have a glass or barrier partition above the counter to enclose it. In limited circumstances, offices can also elect to keep the main customer entrance door secured at all times and have a buzzer or intercom installed at the secure door to communicate with visitors. In this configuration, a hardened customer service counter is not required since the office is secure.
2. Entrance Door Chime: An entrance door chime shall be installed on the main/customer entrance to notify employees when a visitor enters the facility to increase employee situational awareness.
3. Duress/Panic Buttons: All USDA Main Entrance/Reception areas shall have a duress/panic alarm installed that is monitored. Additional duress/panic buttons shall be placed in all areas that employees routinely service customers.
4. Intrusion Detection System (IDS) Coverage and Monitoring: All offices shall have an
Intrusion Detection System (IDS) alarm installed. This system shall consist of door contacts for all perimeter entry and exit doors to USDA space; magnetic contacts for operable ground floor windows, acoustic glass break detectors for glass doors, doors with glass windows, or ground level windows; passive infrared motion sensors (if needed); an alarm keypad (one needed per office suite); and an auto-dialer for alarms to annunciate to a monitoring service for after-hours monitoring.
PAGE 8 LESSOR: ______ GOVERNMENT: ________
5. Main/Customer Entrance Emergency Lockdown: A locking device is required on the main/customer entrance that will easily allow for locking/unlocking the door in emergencies.
To support an emergency lockdown, a thumb turn deadbolt, or some other device shall be installed on the main entrance door so the door can be locked immediately in an emergency.
6. Space Compartmentalization - False Ceiling: Any suspended (false) ceilings that lead into
USDA-FPAC space from a wall in a common hallway or other tenants’ space must be secured in a manner that no individual can enter USDA space undetected or unmonitored by exploiting the gap above the false ceiling wall. The preferred method of securing the space is to install “slab to slab” walls that separate the USDA space from the rest of the facility.
However, installing steel fencing mesh affixed to the true ceiling and the existing walls or drywalling the open area are also acceptable.
7. Perimeter Doors and Door Locks Leading to USDA-FPAC Space: Perimeter doors to
USDA space must be either glass storefront doors, metal high-security doors, or solid-core wood doors. Hollow core doors are not permissible. Door hinges must be located on the inside of the door (non-public side), or exposed door hinge pins must be permanently secured to prevent removal. Approved methods include tack welding or locking screws to hold pin in place. Perimeter door locks must be either electronic access control, high security cipher, or high-security mechanical locks, preferably with a dead-bolt. Cipher locks are highly encouraged to avoid the need to issue keys. All exposed door locking mechanisms, except for deadbolts, must be covered by a door strike plate cover to prevent the mechanism from tampering. All doors without a window, shall have a peephole installed in the door. All door locks shall be rekeyed prior to USDA leasing the space and all keys must be accounted for.
8. Emergency Exit Doors: Emergency exits doors shall include an automatic door closer and exit hardware that is compliant with applicable life safety codes and standards. All emergency exits doors shall have signage posted on the interior side of the door stating, “Emergency Exit Only”. Emergency Exit doors shall have no visible hardware on the exterior.
9. Window Air-Conditioning (A/C) Unit Protection: If window A/C units are installed, they must be secured with a lockable cage or window bars in a way that prevents the window unit from being pushed in or removed.
10. Protection of Exterior Gas Mains or Propane Tanks Adjacent to Premises: If there is exposed gas mains/meters or propane tanks near a facility façade or in a parking lot, they must have bollards (typically yellow safety bollards) or some other barrier (i.e., boulder) placed around it to protect it from a vehicle strike.
11. Security of Exterior Electrical Panels and Switches: If applicable, exterior electrical panels on the outside of the building or in common/public space shall be secured via a locking device, unless not permitted by local code. The preferred location for electrical panels is inside the USDA space or in a secured area on the interior of the building.
12. Public Restroom Access: Lessor must secure public restrooms (restrooms located in the building common area) in a manner that only facility tenants can access them and not the general public. This can be done by securing the restrooms with either a hard key or an access code.
13. Fire and Carbon Monoxide Detection: Ensure an appropriate amount of smoke and carbon monoxide detection devices as needed and in accordance with local code.
14. Perimeter Lighting: Ensure that the building exterior entrances/exits are illuminated to a minimum of 5 foot-candles; Sidewalks and walkways illuminated to a minimum of 3 foot-candles; and Parking lot surfaces illuminated to 1 foot-candle throughout the parking areas.
Lighting must meet this standard at all times in periods of darkness. Only having motion activated lighting is not sufficient.
PAGE 9 LESSOR: ______ GOVERNMENT: ________
15. Interior Office Doors: Interior doors to offices, conference rooms, restrooms, and break rooms shall not be hollow core wood or any other interior residential use door. Doors shall be solid core wood or equivalent. All doors to private offices shall have door locking mechanism (residential use internal locks are not permitted).
16. Landscaping: Landscaping shall be maintained and trimmed as needed to prevent it from creating areas of concealment around the facility and parking areas. Landscaping shall not be overgrown where it impacts lighting illumination, camera views (if applicable), and a clear line of sight.
F. EVSE REQUIREMENTS (TO BE INCLUDED IN TENANT IMPROVEMENT COSTS):
The Lessor shall provide Electric Vehicle Supply Equipment (EVSE) supporting infrastructure for Charging Station(s) and reserved parking spaces for electric vehicles. Infrastructure shall comply with all local electrical codes, and if none, the National Electrical Code (current edition).
1. Install the supporting infrastructure for 04 dual-port Level 2 EVSE Charging Stations in support of USDA’s electric vehicles.
2. USDA, or designated contractor, will furnish, install, and maintain dual-port Level 2 EVSE Charging Stations with SAE J1772 connectors and networked software systems for remote management to monitor, maintain, and allow access.
3. Lessor shall obtain all required permits for the installation and construction of supporting infrastructure of the EVSE Charging Station(s).
4. Lessor shall complete all requirements with special emphasis on the following required improvements:
a. Install conduit and all other required base-building electrical infrastructure necessary to support electric service to USDA’s EVSE Charging Station(s) at a location approved by the USDA.
b. Dedicated single-phase electrical circuit(s) (32A at 208/240V).
c. A dual pole 40A circuit breaker(s) at the electrical panel is required for each charging station. (e.g., 2 charging stations, 2 40 Amp Circuit Breakers).
d. Conductor wiring sized in accordance with the National Electrical Code requirement for
125% capacity for continuous load for all branch circuits from panel to stations via raceway or conduit with required grounding conductor.
e. For pedestal mount stations prepare pad and a minimum 36” coiled wiring remains above conduit stub for station connection.
f. Location must have a consistent cellular signal for networked station use.
5. Install bollards protecting stations and signage identifying that the EVSE is for USDA EGOV use only.
PAGE 10 LESSOR: ______ GOVERNMENT: ________
G. MLRE Lab Specs:
MLRA Soil Survey Office Specifications
1. Office needs to be accessible through both front and back doors.
2. Soil Survey Field Laboratory Requirements
2.1. 300 Square Feet – acoustically treated insulated interior partitioning to provide STC 50
(suggested layout provided in Figure 1, attached).
2.2. Provide and install a stainless steel double bowl sink in a minimum 6 foot long base kitchen-type locking cabinets with countertop and sink to measure 33” x 22” x 7” with hot and cold running water and high spout clearance facet. Provide and install minimum 3 foot long overhead cabinet.
2.3. At opposite end of sink on the fixed counter, provide and install overhead vent outlet to accommodate benchtop fume hood (see attached example, Figure 2).
2.4. Provide two (2) 110-volt, 20 amp dedicated circuits, each with isolated grounding with 2 duplex outlets evenly spaced above the countertop.
2.5. Provide one (1) each 110-volt, 20 amp dedicated circuits with 2 duplex outlets at standard floor level on walls adjacent to and opposite of the installed sink counter.
2.6. Provide and install OSHA certified combination eyewash station and emergency shower adjacent to sink area, with ground drain (see attached example, Figure 3).
2.7. Provide and install locking doorknob on outside door.
3. Soil Survey Equipment, Sample and Document Storage Requirements
3.1. 150 Square Feet, attached to laboratory space and accessible by a single door into the laboratory only.
3.2. Provide and install fixed ¾” thick, 18” deep shelving on the shortest wall adjacent to the door opening wall (away from door area, not on wall with door installation).
| 3d OR Malheur RLP Amendment 5 |
| Agency Specific Requirements (JAN 2024)8.23.2024 |
| A. room schedule |