This document contains an interior finishes binder and related federal contract opportunity notice for repair and renovation work at DFAC Building 56425 at Fort Hood, Texas. The interior finishes binder specifies materials for ceilings, flooring, wall finishes, paints, lockers, and other interior elements. The related federal contract opportunity is a firm-fixed price design-bid-build contract issued by the US Army Corps of Engineers Fort Worth District. Interested parties must register in the System for Award Management to be eligible for the contract award, which is anticipated in September 2021. The contract period of performance is 480 days after notice to proceed. The project scope involves repair and renovation of an existing dining facility to upgrade it and replace electrical, mechanical, and architectural finishes to comply with current Army DFAC standards.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Finish

DFAC BUILDING 56425

Project Number:

Location:

Date:

Prepared by:

490406 Ft. Hood, TX June 2021

Lori Harris Interior Designer US Army Corps of Engineers Fort Worth District lori.m.harris@usace.army.mil 816.886.1671

TABLE OF CONTENTS

Interior Finishes

ACOUSTICAL CEILING TILE (ACT)

ACT ‐ Armstrong, Ultima Lay‐In and Tegular, Item: 1911HRC, Size: 24 in. x 24 in. x 3/4 in., Color: White, Edge: Beveled Tegular 15/16 in.

PORCELAIN TILE (PT)

PT-1: FLOOR TILE, MANUFACTURER: DALTILE, MODEL/COLOR: EMERSON WOOD/EP05 HICKORY PECAN, SIZE: 8X48 PLANKS, NOTES: OFFSET/STAGGERED LAY

PT-2: FLOOR TILE, MANUFACTURER: DALTILE, MODEL/COLOR: EMERSON WOOD/EP05 HICKORY PECAN, SIZE: 12X12 3D CUBE MOSAIC

PT-3: FLOOR TILE, MANUFACTURER: DALTILE, MODEL/COLOR: EXHIBITION EX02 GRAY UNPOLISHED, SIZE: 12X24, NOTES: BRICK LAY

QUARRY TILE (QT)

QT: QUARRY TILE, MANUFACTURER: DALTILE, MODEL/COLOR: QUARRY TILE/ ASHEN GRAY 0T03, SIZE:

8X8, NOTES: STRAIGHT LAY

WALL TILE (WT)

WT-1: WALL TILE, MANUFACTURER: DALTILE, MODEL/COLOR: EXHIBITION EX02 GRAY UNPOLISHED, SIZE: 12X24, NOTES: STRAIGHT LAY

WT-2: WALL TILE, MANUFACTURER: DALTILE, MODEL/COLOR: COLOR WHEEL LINEAR/ NAVY K189, SIZE:

4"X12", NOTES: SEE DRAWINGS

FIBERGLASS REINFORCED PANELS (FRP)

FRP- Marlit. Symmetrix C100 G63, Color: white, Height: 4”

PAINT (PNT)

PNT-1: PAINT (WALLS), MANUFACTURER: SHERWIN WILLIAMS, MODEL/COLOR: SW 7029 AGREEABLE

GRAY, SATIN FINISH

PNT-2: PAINT (CEILINGS) MANUFACTURER: Sherwin Williams, Color: SW 7006 Extra White, FLAT FINISH

PNT-3: PAINT (TRIM) MANUFACTURER: Sherwin Williams, Color: SW7069 Iron Ore, ENAMEL FORMULA

SOLID SURFACE (SS)

SS: SOLID SURFACE, MANUFACTURER: WILSONART, MODEL/COLOR: MOON GEYSER 9209 CM

TOLIET PARTITIONS (TP)

TP: Scranton Products, Hiny Hiders, Color: Shale, Orange Peel (Texture)

LOCKER (LK)

LK: LOCKER, MANUFACTURER: LYON, MODEL/COLOR: MONORAIL GRAY/GY655‐7G

WALK OFF MATT (WM)

WM- Milliken, Obex Grid CuteX 11 Closed, Color: Dark GreyFZX118‐119, Insulation: Surface Mounted

WINDOW SHADES (WS)

WS- Mecho, Ecoveil screens 1550 Series (3% open), Color: 1554 Black/Brown

INTERIOR FINISHES

DFAC DINING—NORTH FT. HOOD

PNT –1 (PAINT) PNT-2 (PAINT)

PNT –3 (PAINT) WS

PT-1 PT-2

PT-3/WT-1 QT

WT-2 TP

SS LK

WM FRP

ACT

5'

0"6'

0"

9'

0"

WT-1

WT-2

NOTES

1. COLOR DESIGNATIONS ARE INDICATED IN SECTION 09 06 00 SCHEDULE FOR FINISHES.

2. MOISTURE RESISTANT GYPSUM BOARD SHALL BE PROVIDED IN THE RESTROOMS.

3. PAINT ALL METAL DOORS AND FRAMES P-3.

4. NORTH, SOUTH, EAST AND WEST AS NOTED ON THE ROOM FINISH SCHEDULE SHALL BE IN ACCORDANCE WITH PLAN NORTH

AS INDICATED ON THE ARCHITECTURAL FLOOR PLANS IN THIS DRAWING SET.

5. PAINT ALL INTERIOR WALL AND CEILING MOUNTED ITEMS AS SUCH AS VENTS, GRILLE COVERS AND FIRE EXTINGUISHER CABINET FACES AND FRAMES. LIGHT FIXTURES TRIM RINGS, STC TO MATCH SURFACE COLOR ON WHICH THEIR APPEAR.

6. PROVIDE AND INSTALL WINDOW TREATMENTS (WT) FOR ALL WINDOWS. ALL WINDOW TREATMENTS SHALL UTILIZE AN

"INSIDE" MOUNT METHOD.

7. REFER TO ARCHITECTURE DRAWINGS FOR PARTITION TYPES AND CONSTRUCTION.

8. REFER TO ARCHITECTURE DRAWINGS FOR CEILING TYPES AND HEIGHTS.

PNT

CVB

SC

PAINT

COVE BASE

SEALED CONCRETE

INTERIOR FINISH LEGEND

ACT ACOUSTICAL CEILING TILE

CODE MATERIAL

PT PORCELEAIN TILE

QTB

GYP

QUARRY TILE BASE

WALL TILE

GYPSUM BOARD

WT

FRP FIBERGLASS REINFORCED PANELS

QT QUARRY TILE

SHEET

NUMBER

D ra w n by

D es ig ne d by

Su bm itt ed b y:

Sh ee t S iz e

AN

SI

D

D at e:

C on tra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

FO

R

T W

O R

TH

D

IS

TR

IC

T

TA

YL

O R

S

TR

EE

T

FO

R

T W

O R

TH

, T

EX

AS

C he ck ed b y:

US Army Corps of Engineers ®

A

R ev

M ar k D es cr ip tio n Tr ac ki ng N o.

Ac tio n

D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

PLOT DATE:

2 3 4 5 6 7 8 9 10

B

C

D

E

F

G

Fort Worth District

FILE PATH:

PLAN NORTH

1/20/2021 11:52:57 AM

FO

R

T H

O O

D ,T

EX

AS

R

EP

AI

R

D

FA

C B

U

IL

D

IN

G

PN

: 4

JA

N U

AR

Y

L.

H

AR

R

IS

L.

H

AR

R

IS

JE

N

N

IF

ER

A

. D eW

IT

T, R .A

C

H

IE

F, A

R C

H

IT

EC

TU

R E

SE

C

TI

O

N

I-601

FI

NI

SH

S

CH

ED

UL

E

H .K

IM

BR

O W

PROJECT NAME

INTERIOR FINISH SCHEDULE

Z ROOM NAME FLOOR BASE WALL FINISH CEILING NOTESNORTH EAST SOUTH WEST

101 WOMEN PT-2 CVB-1 WT-1/WT-2 WT-1/WT-2 WT-1/WT-2 WT-1/WT-2 GYP

102 MEN PT-2 CVB-1 WT-1/WT-2 WT-1/WT-2 WT-1/WT-2 WT-1/WT-2 GYP

103 ENTRY VESTIBULE PT-2 CVB-1 PNT-1 PNT-1 PNT-1 PNT-1 GYP

104 DINING PT-1 CVB-2 PNT-1 PNT-1 PNT-1 PNT-1 ACT/GYP SEE A-131 REFLECTED CEILING PLANS

105 SERVING LINE PT-1 CVB-2 PNT-1 PNT-1 FRP FRP ACT INSTALL FRP FLOOR TO CEILING

106 DRY STORAGE QT QTB PNT-1 PNT-1 PNT-1 PNT-1 GYP

107 FIRE RISER ROOM SC - PNT-1 PNT-1 PNT-1 PNT-1 GYP

108 COMPRESSOR QT QTB PNT-1 PNT-1 PNT-1 PNT-1 GYP

109 RECEIVING QT QTB PNT-1 PNT-1 PNT-1 PNT-1 GYP

110 OFFICE PT-1 CVB-2 PNT-1 PNT-1 PNT-1 PNT-1 ACT

111 ELECTRICAL SC - PNT-1 PNT-1 PNT-1 PNT-1 GYP

112 PAPER ST QT QTB PNT-1 PNT-1 PNT-1 PNT-1 GYP

113 KITCHEN QT QTB PNT-1 PNT-1 PNT-1 PNT-1 ACT

114 MECHANICAL SC - PNT-1 PNT-1 PNT-1 PNT-1 GYP

115 POT WASH QT QTB PNT-1 PNT-1 PNT-1 PNT-1 GYP

116 MEN PT-3 CVB-1 WT-1/WT-2 WT-1/WT-2 WT-1/WT-2 WT-1/WT-2 GYP

117 WOMEN PT-3 CVB-1 WT-1/WT-2 WT-1/WT-2 WT-1/WT-2 WT-1/WT-2 GYP

118 SERVING LINE PT-1 CVB-2 FRP PNT-1 PNT-1 FRP ACT INSTALL FRP FLOOR TO CEILING

119 DINING PT-1 CVB-2 PNT-1 PNT-1 PNT-1 PNT-1 ACT/GYP SEE A-131 REFLECTED CEILING PLANS

123 DISHWASHING QT QTB FRP FRP FRP FRP GYP INSTALL FRP FLOOR TO CEILING

NTS1/2" = 1'-0"A1 TYPICAL WALL TILE PATTERN

490406_Hood_Repair_DFAC_Bldg_56425-DMMA_95%- I-601 - FINISH SCHEDULE.pdf
Sheets
I-101 - FURNITURE FLOOR PLAN
I-601 - FINISH SCHEDULE
I-611 - SIGNAGE SCHEDULE

File details come from the government source that posted it. Updated .