549-21-400 BID Drawings.pdf
PDF 12 MB Posted
- Solicitation number
- 36C25723B0019
About this file
This document outlines a federal contract opportunity for construction services. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17 is soliciting bids through solicitation number 36C25723B0019 to construct Building 6 at a VA medical center as a COVID-19 waiting area and conduct HVAC buildback work. Bidders are invited to submit responses by January 15, 2022 to renovate approximately 5,000 square feet of an existing building to serve as an isolated waiting area for patients with potential COVID-19 symptoms. The work includes installing new HVAC systems, walls, doors, flooring and other items required to prepare the designated wing. The contract award is expected by February 28, 2022 for a one-year period of performance beginning April 1, 2022.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| site visit no 3 549-21-400.pdf | ||
| 36C25723B0019 0004.docx | DOCX document | |
| RFIs-23B0019 (001).docx | DOCX document | |
| BLDG6 asbestos.pdf | ||
| 36C25723B0019 0003.docx | DOCX document | |
| second visit 549-21-400 012623.pdf | ||
| 36C25723B0019 0002.docx | DOCX document | |
| 36C25723B0019 0001.docx | DOCX document | |
| signin sheet 549-21-400.pdf | ||
| 36C25723B0019_1.docx | DOCX document | |
| 549-21-400 Bound Specifications.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
v v v v v v v v v v v v v v v v v v v v v
CO
WV
CO
ICV
RD
RD
RD
RD
RD
DRRDRD DR
WV
RD RD
RD
SS
CO
CO
MH
WV
WV
FDC
LANCASTER ROAD LANCASTER ROAD
ANN A
RBOR A
VENUE
A N
N A
R B
O R
A V
E N
U E
G
LA
D E
W A
T E R
ASPH ALT
PAVEMENT
SIGN
S EC URI TY
TR
B A 101
I T/ TEL TR
S -01 S -02
X
X
X
X
X
X
X
X x x x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XX
XX
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X
X
X
XX
X
X
001001 001
001 001001
001 001 001 001 001
S P A C E
X
X X X
X
X X
X
X
X
X
X X
XX X
X
X
X
X X
X
X
X X
X
X
X X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X XX XX X XXX XX XXX X
X
X
X
X
X
X
X
X
X
X
X
X
X X XX XXX XX XXX XX X XX X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
Car Shown is Full Size Car (18' X 6'5)
Rough Draft, 41 Spaces
ENERGY CENTER CTR.
V E T E R
A N
S D
R
IV
E
LIBERTY LOOP LIBERTY LOOP
LIBERTY LOOP
LIBERTY LOOP
L I B
E R
T Y
L O
O P
L
IB
E R
T Y
L O
O P
L I B
E R
T Y
LOOP
L
IB
E R
T Y
L O
O P
6TH STREET
S
T S
T R
E E
T S
T S
T R
E E
T
A V
E N
U E
O F
F L A
G S
A V
E N
U E
O F
F L A
G S
INDUSTRIAL PARK INDUSTRIAL PARK
R
D S
T R
E E
T
ENERGY CENTER CTR.
4T H
S T R
E E T
MAINMAIN SOUTH
NORTH
X
X
X
X
X
X
X
X
X
X
X
X
X x x x x x x x x x x x x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X
X X
X X
X X
X
X
X
PROJECT
LOCATION
BUILDING 6
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
U.S. DEPARTMENT OF VETERANS AFFAIRS
VA Health Care System Approval:
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913)-369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
PARTIALLY SPRINKLERED
ENVIRONMETAL ENGINEER
RSH
11140 SOUTH TOWNE SQUARE, SUITE 100
SAINT LOUIS, MO 63123
(314) 917-0148
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Drawing Number
Building Number
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 09/30/2021
ENGR REG. NO. EXP. 02/28/2022
4 5 6
STAMP:
TX BR2171,
TX F-17591,
SPUR # 2090.02
/1
/2
:0
:2
A
M
COVER SHEET
NR 01 46BGJ
BID DOCUMENTS
BUILDING 6 COVID-19 BUILD BACK WITH
HVAC
VA PROJECT NUMBER: 549-21-400
BUILDING 6 COVID-19 BUILD
BACK WITH HVAC
09/14/2021
549-21-400
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD.
DALLAS, TX 75216
VA NORTH TEXAS HEALTH CARE SYSTEM
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD.
DALLAS, TX 75216
BID DOCUMENTS
GI000
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[01] GENERAL
01 GI000 COVER SHEET
02 GI001 GENERAL INFORMATION
[02] STRUCTURAL
03 SA001 STRUCTURAL GENERAL NOTES
04 SA030 TYPICAL DETAILS - CONCRETE
05 SF101 EXISTING ATTIC FRAMING PLAN
06 SF102 EXISTING ROOF SUBSTRUCTURE FRAMING PLAN
07 SF103 EXISTING ROOF FRAMING PLAN
08 SF201 FRAMING/BRACING ELEVATIONS
[03] ENVIRONMENTAL
09 HA001 BASEMENT LEVEL HAZARDOUS MATERIALS
10 HA101 LEVEL 1 HAZARDOUS MATERIALS
11 HA201 LEVEL 2 HAZARDOUS MATERIALS
12 HA301 ATTIC LEVEL HAZARDOUS MATERIALS
13 HA401 ROOF LEVEL HAZARDOUS MATERIALS
[04] ARCHITECTURAL
14 AD011 DEMOLITION PLANS
15 AE021 PARTITION TYPES, SCHEDULES, AND DETAILS
16 AE111 REFERENCE AND DIMENSION PLANS
17 AC131 REFLECTED CEILING PLANS
18 AF701 INTERIOR MATERIALS AND FINISHES
[05] FIRE PROTECTION
19 FA001 FIRE ALARM / MASS NOTIFICATION GENERAL NOTES
20 FA101 FIRE ALARM AUDIBILITY PLANS
21 FA102 FIRE ALARM PLANS
22 FX001 FIRE SUPPRESSION GENERAL NOTES
23 FX101 FIRE SUPPRESSION HAZARD CLASSIFICATION GROUND FLOOR PLAN
[06] MECHANICAL
24 M-000 LEGEND AND ABBREVIATIONS
25 MD101 MECHANCIAL HVAC PIPING DEMOLITION PLANS - BASEMENT & LEVEL 1
26 MD102 MECHANICAL HVAC PIPING DEMOLITION PLANS - LEVEL 2 & ATTIC
27 MD103 MECHANICAL HVAC DUCT DEMOLITION PLANS - BASEMENT & LEVEL 1
28 MD104 MECHANICAL HVAC DUCT DEMOLITION PLANS - LEVEL 2 & ATTIC
29 MP101 MECHANICAL HVAC PIPING PLANS - BASEMENT & LEVEL 1
30 MP102 MECHANICAL HVAC PIPING PLANS - LEVEL 2 & ATTIC
31 MH101 MECHANICAL HVAC DUCT PLANS - BASEMENT & LEVEL 1
32 MH102 MECHANICAL HVAC DUCT PLANS - LEVEL 2 & ATTIC
33 M-201 MECHANICAL FLOW DIAGRAMS
34 M-501 MECHANICAL DETAILS
35 M-601 MECHANICAL SCHEDULES
36 M-701 MECHANICAL CONTROLS
37 M-702 MECHANICAL CONTROLS
38 M-703 MECHANICAL CONTROLS
39 M-704 MECHANICAL CONTROLS
[07] ELECTRICAL
40 EP000 ELECTRICAL LEGENDS AND ABBREVIATIONS
41 ED101 ELECTRICAL DEMOLITION POWER PLANS
42 ED102 ELECTRICAL DEMOLITION LIGHTING PLANS
43 EP101 ELECTRICAL POWER PLANS
44 EP102 ELECTRICAL LIGHTING PLANS
45 EP201 ELECTRICAL SCHEDULES AND ONE-LINE DIAGRAM
46 EP202 ELECTRICAL DETAILS
TOTAL SHEETS: 46
LOCATION PLAN
PROJECT
LOCATION
CAMPUS MAPN
N
No. REVISION DESCRIPTION DATE
ABBREVIATIONS CODES STANDARDS AND EXECUTIVE ORDERS
4' -0
M
A X
4' -0
M
A X
2' -1
0" M
A X
2' -3
M
IN
1'-6" MIN
1. GENERAL CONTRACTOR TO PROVIDE METAL SUPPORT
BLOCKING FOR ALL WALL MOUNTED ACCESSORIES,
FIXTURES, AND EQUIPMENT.
2. PROVIDE ADA SUPPORT BRACKETS PLACED AT ALL OPEN
COUNTERTOPS @ 36"-48" MAX ON CENTER.
3. SPECIFIED MAXIMUMS ARE MEASURED FROM AFTER
FINISHED FLOOR TO THE OPERABLE PART OF THE FIXTURE.
4. FIXTURES SHOWN ARE REPRESENTATIONAL ONLY. NOT ALL
FIXTURES MAY BE USED. REFER TO SPECIFICATIONS FOR
FIXTURE TYPES USED IN THIS PROJECT.
5. FIXTURES MAY OVERLAP WAINSCOT. WHERE APPLICABLE,
BACKING TO BE PROVIDED AS SHIM FOR FLUSH
APPLICATION. SHIM TO MATCH SCHEDULED WALL FINISH.
6" MAX
9" M
IN
SHOWER
TOILET ROOM
TURNING RADIUS
DRINKING
FOUNTAIN
PAPER TOWEL
DISPENSER
SANITARY
NAPKIN
DISPENSER
4' -0
"M A
X
WASTE
RECEPTACLE
LAVATORY
WITH MIRROR
ON CENTER
WALL
4' -0
M
A X
SOAP
DISPENSER
2' -1
0" M
A X
T O
B .O
. R E
F
LE
C T
IV
E
S U
R F
A C
E
3' -4
"M A
X
17 MIN
2' -3
M
IN
3' -0
M
A X
1'-6" MIN
WALL
2' -9
" 4' -0
M
IN
2'-0" MIN
8" MIN
WALL
LAVATORY
WITH APRON
1' -5
M
A X
1'-6" MIN
URINAL
WALL
1'-5" - 1'-7" (AMBULATORY)
1'-4" - 1'-6" (WHEELCHAIR)
CLEAR FLOOR
5'-6"
CLEAR FLOOR
6'-0"
3'-0" MIN
2' -9
3' -0
1'-0" MIN
3'-6" MIN 1'-0"MAX
4'-6" MIN
1' -5
'-7
1' -6
M
IN
A N
S I I
C C
A
7.
1)
1' -3
M
IN
A D
A /A
B A
2' -9
'-0
WALL
WALL
4' -0
M
A X
WALL HOOK
7' -0
CLOCK
WALL
FINISHED FLOOR
FIRE EXTINGUISHER
CABINET
WEIGHT > 40LBS
FIRE EXTINGUISHER
CABINET
WEIGHT < 40LBS
4' -0
"M A
X
4' -0
M
A X
TOILET SEAT
COVER
DISPENSER
BABY
CHANGING
STATION
CLEAR FLOOR SPACE
@ WATER CLOSET
5'-6"
2'-6"
4' -0
2'-6"
4' -0
HANDRAILS AND
BUMPERGUARDS
FIXTURE MOUNTING HEIGHTS AND CLEARANCES
18" MIN
M
IN
FRONT APPROACH,
PULL SIDE
36" MIN
M
IN
HINGE APPROACH,
PULL SIDE
HINGE APPROACH,
PULL SIDE
*12" MIN48
M
IN
FRONT APPROACH,
PUSH SIDE
M
IN
HINGE APPROACH,
PUSH SIDE
22" MIN 24" MIN
*4 8"
M
IN
LATCH APPROACH,
PULL SIDE
24" MIN*4
2"
M
IN
LATCH APPROACH,
PUSH SIDE
*IF BOTH CLOSER
AND LATCH ARE
PROVIDED
*54" MIN IF CLOSER
IS PROVIDED
*48" IF CLOSER IS
PROVIDED
FRONT APPROACH,
PUSH SIDE
M
IN
42" MIN
DOOR AND FIXTURE CLEARANCES
MATERIALS LEGEND
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN
VOLUNTARY STANDARD BODIES.
GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS
SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL
INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
• 2015 INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)
• 2003 INTERNATIONAL EXISTING BUILDING CODE (IEBC) (IF APPLICABLE)
• 2021 NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
• 2015 INTERNATIONAL FIRE CODE
• 2021 NFPA 5000 BUILDING CONSTRUCTION AND SAFETY CODE
• 2019 NFPA 900 BUILDING ENERGY CODE
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
• 2017 NATIONAL ELECTRICAL CODE (NEC), NFPA 70
• 2015 INTERNATIONAL PLUMBING CODE (IPC)
• 2016 SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.
• 2015 ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS INCLUDING VA SUPPLEMENT, VA BARRIER FREE DESIGN STANDARD (PG-18-13)
• 2017 ANSI ICC A117.1 ACCESIBLE AND USABLE BUILDINGS AND FACILITIES
• 2019 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318-19)
• 2017 STEEL CONSTRUCTION MANUAL (15TH EDITION), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
• ENERGY POLICY ACT OF 2005 (EPACT)
• 2007 DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND
NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.
• 2006 FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
• 2018 EXECUTIVE ORDER 13834: EFFICIENT FEDERAL OPERATIONS
• 2021 THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 010000 OF THE VA MASTER CONSTRUCTION
SPECIFICATION.
• 2019 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1
• 2019 SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT
NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN.
DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES
EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
ASHRAE 90.1 - 2019 EDITION
BUILDING LOCATION: DALLAS, TX
CLIMATE ZONE (TABLE ANNEX 1-1): ZONE 2A
INTERIOR DESIGN CONDITIONS:
THE INTERIOR DESIGN TEMPERATURES FOR HEATING AND COOLING AS DEPICTED IN THE PROJECT DESIGN CONDITIONS SCHEDULE IN THE MECHANICAL CONTROL DRAWINGS SHALL BE THE MAXIMUM
AND MINIMUM VALUES FOR THE ASSOCIATED TEMPERATURE CONTROL ZONES.
BUILDING ENVELOPE REQUIREMENTS (5.5 )
BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 2A (TABLE 5.5-2)
REQUIRED DESIGNED
SLAB-ON-GRADE FLOORS
UNHEATED SLABS: NR . EXISTING
HEATED SLABS: R-10 for 24 in. EXISTING
FLOORS
MASS: NR EXISTING
STEEL JOIST: R-30 EXISTING
WOOD FRAMED AND OTHER: R-30 EXISTING
WALL, BELOW GRADE
BELOW-GRADE WALL: NR EXISTING
WALLS, ABOVE GRADE
MASS: R-7.5 c.i. EXISTING METAL BUILDING: R-13 + R-13 c.i. EXISTING STEEL-FRAMED: R-13 + R-7.5 c.i. EXISTING WOOD-FRAMED AND OTHER: R-13 + R-3.8 c.i. or R-20 EXISTING
WALLS, ABOVE GRADE
MASS: R-5.7 c.i. EXISTING METAL BUILDING: R-0 + R-9.8 c.i. EXISTING STEEL-FRAMED: R-13 + R-3.8 c.i. EXISTING
WOOD-FRAMED AND OTHER: R-13 EXISTING
ROOFS
INSULATION ENTIRELY R-25 c.i. EXISTING
ABOVE DECK
METAL BUILDINGS (WITH R-5
THERMAL BLOCK R-10 + R-19 FC EXISTING
ATTIC AND OTHER: R-38 EXISTING
FENESTRATION (TABLE 5.5-2):
VERTICAL FENESTRATION, U-FACTOR
NON METAL: U-0.37 EXISTING
FIXED: U-0.54 EXISTING
OPERABLE: U-0.65 EXISTING
ENTRANCE DOOR: U-0.83 EXISTING
DEFINITIONS
c.i = CONTINUOUS INSULATION Ls = LINEAR SYSTEM
NR = NO (INSULATION) REQUIREMENT
N/A = NOT APPLICABLE
ENERGY REQUIREMENTS
N
1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL
CONFIRM ALL ITEMS REQUIRED BASED UPON THE OVERALL DESIGN INTENT OF THE
ENTIRE DOCUMENT SET.
2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, PRIOR TO BEGINNING ANY
WORK, TO CONFIRM THE ACCURACY OF THE DRAWINGS AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT. DO NOT SCALE THE DRAWINGS. FIELD VERIFY
ALL DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE KEPT
CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.
4. ERECT BARRICADES AND WARNING SIGNS TO DIVERT AND WARN PASSERS-BY OF THE
CONSTRUCTION WORK. PROVIDE DUST PROOFING ENCLOSURES TO SEPARATE WORK
AREAS FROM THE EXISTING FACILITIES.
5. ALL TRASH AND DEBRIS TO BE REMOVED ON A DAILY BASIS.
6. PROVIDE PROTECTION FOR ALL EXISTING SURFACES AND CONDITIONS TO REMAIN IN
PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND
REPAIR ANY DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.
7. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE REPAIRED
OR REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL COST TO THE
OWNER.
8. COVER ALL RETURN AIR GRILLES WITHIN THE AREA OF CONSTRUCTION TO PREVENT
PARTICULATE MATERIAL FROM EXHAUSTING INTO SURROUNDING SPACES.
9. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY SUSPENDED TO PROVIDE
ADEQUATE LIGHTING LEVELS FOR CONSTRUCTION.
10. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH OTHER
DISCIPLINES TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS. DRAWINGS, AS A
WHOLE, REPRESENT A COMPLETE SET AND DEPICT REQUIREMENTS FOR COMPLETE
AND OPERATIONAL SYSTEMS. INDIVIDUAL DRAWINGS MAY NOT DEPICT COMPLETE AND
ACCURATE INFORMATION TO COORDINATE COMPLETE AND OPERATIONAL SYSTEMS,
BUT DO SO AS AN ENTIRE DOCUMENT TO BE REFERENCED WITH OTHER INDIVIDUAL
DRAWINGS. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO REFERENCE
OTHER SHEETS AND SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION
DOCUMENTS THAT REFLECT WORK REQUIRED TO ACHIEVE A COMPLETE AND
OPERATIONAL GOAL. LACK OF COORDINATION AND REVIEW OF DRAWINGS AND
SPECIFICATIONS AS AN ENTIRE DOCUMENT TO INSTALL COMPLETE AND OPERATIONAL
SYSTEMS, BEING OBVIOUS AND TYPICAL INDUSTRY STANDARD, IDENTIFIED IN THE
DRAWINGS AND SPECIFICATIONS, SHALL NOT BE IN ANY WAY AN ADDITIONAL COST TO
THE GOVERNMENT.
11. CONTRACTOR SHALL SUBMIT A REQUEST, IN WRITING, TO INTERRUPT ANY SUCH
SERVICES TO COR (CONTRACTING OFFICER’S REPRESENTATIVE) 48 HOURS IN
ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE,
EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. MAJOR
INTERRUPTIONS OF ANY SYSTEM MUST BE REQUESTED, IN WRITING, AT LEAST 60
CALENDAR DAYS PRIOR TO THE DESIRED TIME AND SHALL BE PERFORMED AS
DIRECTED BY THE COR. MAJOR INTERRUPTIONS SHALL BE COORDINATED WITH OTHER
MAJOR INTERRUPTIONS AND MAY NOT BE SCHEDULED FOR ONE DISCIPLINE MORE
THAN TWICE THROUGHOUT THE OVERALL CONSTRUCTION SCHEDULE UNLESS
REQUESTED IN WRITING AND APPROVED BY THE COR. CONTRACTOR WILL BE ADVISED,
IN WRITING, OF APPROVAL OF REQUEST, OR OF WHICH OTHER DATE AND/OR TIME
SUCH INTERRUPTION WILL CAUSE THE LEAST INCONVENIENCE TO OPERATIONS OF
THE MEDICAL CENTER. INTERRUPTION TIME APPROVED BY THE MEDICAL CENTER MAY
OCCUR AT TIMES OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS. SCHEDULE
INTERRUPTION MAY BE ON WEEKENDS OR LATE HOURS AND MAY NOT BE AN
ADDITIONAL COST TO THE GOVERNMENT. COORDINATE ALL INTERRUPTIONS THAT MAY
AFFECT THE NORMAL OPERATION OF THE FACILITY WITH THE COR WHEN SUBMITTING
THE CONSTRUCTION SCHEDULE OR UPDATES TO THE CONSTRUCTION SCHEDULE.
12. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT. SPUR
DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS CONTAINING
BUILDING MATERIALS (ACBM) OR LEAD BASED PAINT (LBP) PRODUCTS WERE
DESIGNED/SPECIFIED AS BUILDING MATERIAL IN ANY OF THE CONSTRUCTION
DOCUMENTS.
13. REFER TO THE DESIGN BINDER FOR THE ICRA INFORMATION DOCUMENTATION.
GENERAL NOTES
AREA NAME
150 SF
A101
A101
SIM
A
00.0
A101
1 1
A101
LEVEL NAME
00'-00"
00'-00" 4B
3A
FIBERGLASS BATT
INSULATION
RIGID INSULATION
CONCRETE / PRECAST
CONCRETE
EARTH / SOIL
SAND, EIFS FINISH, OR
PLASTER FINISH
GYPSUM BOARD FINISH
BRICK
CONCRETE MASONRY
UNIT
STONE / CAST STONE
GYPSUM BOARD SECTION
EXTERIOR SHEATHING
BOARD SECTION
PLYWOOD SECTION
ROOM NAME
000A
150 SF
/1 A101
X0000
6"
3' -0
M
A X
ROOM TAG
AREA TAG
SPECIALTY EQUIPMENT TAG
DOOR TAG
KEYED NOTE TAG
WALL TAG
WINDOW TAG
A101
SIM
A101
SIM
A
ACB ACOUSTIC CEILING BAFFLE
ACP ACOUSTIC CEILING PANEL
ACST ACOUSTIC
ADA AMERICANS WITH DISABILITIES ACT
ACT ACOUSTICAL CEILING TILE
ADDL ADDITIONAL
ADDN ADDITION
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
AE ARCHITECT/ENGINEER
AF ACCESS FLOORING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIA AMERICAN INSTITUTE OF
ARCHITECTS
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINIUM (TRIM)
AMT AMOUNT
APPROX APPROXIMATE
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
AT ACOUSTIC CEILING TILE
AVG AVERAGE
B
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BOS BOTTOM OF STEEL
BOT BOTTOM
BRKT BRACKET
BTWN BETWEEN
C
CAB CABINET
CAV CAVITY
CBB CONCRETE BACKER BOARD
CD CONSTRUCTION DOCUMENTS
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CH BD CHALK BOARD
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CP CONTRACTOR PROVIDED
CP/CI CONTRACTOR PROVIDED /
CONTRACTOR INSTALLED
CPT CAROET/CARPET TILE
CS CONCRETE SEALED
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTR CENTER
CU FT CUBIC FEET
D
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
DWG DRAWING
DWP DIMENSIONAL WALL PANEL
E
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPY EPXOY FLOORING
EQ EQUAL
ETR EXISTING TO REMAIN
EX EXISTING
EXP EXPOSED
EXT EXTERIOR
F
FAB FABRIC
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FP FIRE PROTECTION
FR FIRE RESISTANT
FT FEET
FTG FOOTING
FV FIELD VERIFY
FWC FABRIC WALL COVERING
G
GDR GUARDRAIL
GL GLASS/GLAZING
GRAN GRANITE
GR FL GROUND FLOOR
GT GROUT
GSM GALVANIZED SHEET METAL
GYP BD GYPSUM BOARD
H
HDW HARDWARE
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HMD HOLLOW METAL DOOR PAINT
HMDF HOLLOW METAL DOOR FRAME
PAINT
HMWF HOLLOW METAL WINDOW FRAME
PAINT
HORIZ HORIZONTAL
HR HANDRAIL
HT HEIGHT
HW HARDWARE
I
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J
J-BOX JUNCTION BOX
L
LAV LAVATORY
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIN LINEAR
LN LINOLEUM
LOC LOCATION
LT LIGHT
LVR LOUVER
LVT LUXURY VINYL TILE
M
MAT CARPET MAT / WALK-OFF MAT
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODIFY
MTG MOUNTING
MTL METAL
MVBL MOVABLE
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P
P PAINT
PA PUBLIC ADDRESS
PBD PARTICLE BOARD
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNL PANEL
PR PAIR
PRB PROFILE BASE
PRKG PARKING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PORCELAIN TILE
PWR POWER
Q
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QTY QUANTITY
REFERENCE SYMBOLS IDENTIFICATION TAGS
NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.
GRID HEAD AND
LINE
LEVEL INDICATOR
MATCH LINE AND
VIEW REFERENCE
NORTH ARROW W/
PROJECT NORTH
SPOT ELEVATION
DETAIL
SECTION
**48" MIN IF BOTH CLOSER
AND LATCH PROVIDED
WALL
SECTION
BUILDING
SECTION
DETAIL
ELEVATION
INTERIOR
ELEVATION
BUILDING
ELEVATION
1 1
6'- 0"
5'- 6"
BARIATRIC TOILET ROOM
TURNING RADIUS
CLEAR FLOOR SPACE
@ ADA LAVATORY
CLEAR FLOOR SPACE @ ADA
DRINKING FOUNTAIN
4"
6"
3"
6" 1'
-6
6" MAX
7" - 9" 11" MIN
17" - 25"
M
IN
6' -0
(ANSI ICC A117.1)
39"- 41"
(A N
S I I
C C
A
7.
1)
M
IN
(A N
S I I
C C
A
7.
1)
1"
3' -6
M
A X
5' -0
M
A X
R
RAF RESILIENT ATHETIC FLOORING
RB RUBBER BASE/RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RES RESINOUS FLOORING
RES-W RESINOUS / EPOXY WALL / CEILING
RF RUBBER FLOORING
RFG ROOFING
RM ROOM
RO ROUGH OPENING
RP RESIN PANEL
RSF RESILIENT SHEET FLOORING
RV ROOF VENT
RWC RIGID VINYL WALLCOVERING
S
SC SPECIALTY COATING
SD STATIC DISSIPATIVE FLOORING/TILE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT (FEET)
SGL SINGLE
SIM SIMILAR
SJ SCORED JOINT
SLNT SEALANT
SM SHEET METAL
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SOLID SURFACE
ST STONE
STD STANDARD
STOR STORAGE
SV SHEET VINYL (ROLLED OR TILE)
T
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZO
TOF TOP OF FOOTING/ FOUNDATION
TOM TOP OF MASONRY
TOS TOP OF SLAB/ STEEL
U
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
V
VAR VARIES
VC VA PROVIDED / CONTRACTOR
INSTALLED
VCT VINYL COMPOSITION TILE
VFAT VINYL FACED ACOUSTICLAL TILE
VP VENEERED PLASTER
VT VINYL TILE
VV VA PROVIDED / VA INSTALLED
VWC VINYL WALLCOVERING
VWF VINYL WALL FABRIC
W
W/ WITH
W/O WITHOUT
W/C WATER CLOSET
WC WHEELCHAIR
WD WOOD
WFAB WALL FABRIC
WPM WATERPROOF MEMBRANE
WSF WELDED SHEET FLOOR
X
X BRACE CROSS BRACE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913)-369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
PARTIALLY SPRINKLERED
ENVIRONMETAL ENGINEER
RSH
11140 SOUTH TOWNE SQUARE, SUITE 100
SAINT LOUIS, MO 63123
(314) 917-0148
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Drawing Number
Building Number
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 09/30/2021
ENGR REG. NO. EXP. 02/28/2022
4 5 6
STAMP:
TX BR2171,
TX F-17591,
SPUR # 2090.02
/1
/2
:0
:2
A
M
GENERAL INFORMATION
NR 02 46BGJ
BID DOCUMENTS
BUILDING 6 COVID-19 BUILD
BACK WITH HVAC
09/14/2021
549-21-400
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD.
DALLAS, TX 75216
GI001
GENERAL NOTES
THE STRUCTURAL DRAWINGS DEPICT THE STRUCTURE IN ITS FINAL CONSTRUCTED CONFIGURATION.
NEITHER CONSTRUCTION MEANS AND METHODS NOR CONSTRUCTION SAFETY ARE PART OF THE
STRUCTURAL ENGINEER’S EXPERTISE OR SCOPE OF WORK. THE GENERAL CONTRACTOR AND THEIR
SUBCONTRACTORS ARE FULLY RESPONSIBLE FOR THE MEANS AND METHODS USED TO CONSTRUCT
THE STRUCTURE AND FOR FULL COMPLIANCE WITH ALL JOB SAFETY RELATED REGULATIONS AND CONDITIONS AT THE SITE. LIMITED SITE VISITS, IF ANY, BY THE STRUCTURAL ENGINEER ARE SOLELY
TO OBSERVE COMPLETED PARTS OF THE STRUCTURE. THE STRUCTURAL ENGINEER IS NEITHER
QUALIFIED TO OBSERVE NOR COMMENT ON CONSTRUCTION MEANS AND METHODS AND JOB SITE
SAFETY.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO
FABRICATION/CONSTRUCTION. NOTIFY STRUCTURAL ENGINEER AND ARCHITECT OF ANY
DISCREPANCIES PRIOR TO FABRICATION/CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR ALL
WORK FITTING AS INTENDED BY THE DRAWINGS AND SPECIFICATIONS.
PRINCIPAL OPENINGS ARE SHOWN ON THE DRAWINGS. SEE ARCHITECTURAL, MECHANICAL AND
ELECTRICAL DRAWINGS FOR OPENINGS, SLEEVES, CURBS, INSERTS, DEPRESSIONS, ETC. NOT SHOWN.
ALL DETAILS ARE TYPICAL UNLESS NOTED OTHERWISE. DETAILS SHALL APPLY TO SIMILAR AND LIKE
CONDITIONS.
SHOP DRAWINGS SHALL BE NEW DRAWINGS PRODUCED BY THE CONTRACTOR, ILLEGIBLE
REPRODUCTIONS OF THE DESIGN DRAWINGS WILL BE REJECTED. ELECTRONIC FILES MAY BE
PURCHASED FROM THE ENGINEER OF RECORD FOR THE PURPOSE OF PREPARING SHOP DRAWINGS.
THE CONTRACTOR WILL BE REQUIRED TO SIGN AN INDEMNITY STATEMENT AND FEES FOR THE
ELECTRONIC FILES SHALL BE PAID IN FULL PRIOR TO TRANSMISSION OF THE ELECTRONIC FILES TO
THE CONTRACTOR. THE USE OF REPRODUCTIONS OF THESE CONTRACT DRAWINGS BY ANY
CONTRACTOR, SUBCONTRACTOR, ERECTOR, FABRICATOR, OR MATERIAL SUPPLIER IN LIEU OF
PREPARATION OF SHOP DRAWINGS SIGNIFIES THEIR ACCEPTANCE OF ALL INFORMATION SHOWN
HEREIN AS CORRECT, AND OBLIGATES THEMSELF TO ANY JOB EXPENSE, REAL OR IMPLIED, ARISING
DUE TO ANY ERRORS OR OMISSIONS THAT MAY OCCUR HEREIN.
MINIMUM SHOP DRAWING SUBMITTAL REQUIREMENTS INCLUDE:
CONCRETE MIX DESIGNS FOR EACH CLASS OF CONCRETE WITH TEST DATA
CONCRETE ACCESSORIES (VAPOR BARRIER, REINFORCING SUPPORT CHAIRS, ETC.)
CONCRETE REINFORCING SHOP DRAWINGS
SHORING (SEALED BY A LICENSED PROFESSIONAL ENGINEER)
WOOD FRAMING MATERIALS
THIS PROJECT CONSISTS OF A MODIFICATION TO AN EXISTING BUILDING. INFORMATION ON EXISTING
CONDITIONS HAS BEEN TAKEN FROM THE ORIGINAL DESIGN DRAWINGS AND SHOWN ON THESE
DRAWINGS. THESE DRAWINGS WERE ASSUMED TO BE “AS-BUILT” DRAWINGS SINCE EXISTING
CONDITIONS WERE NOT ACCESSIBLE. IT IS THE CONTRACTOR’S RESPONSIBILITY TO VERIFY ALL EXISTING DIMENSIONS SHOWN ON THESE DRAWINGS AND TO VERIFY THE LOCATION OF ALL FRAMING MEMBERS AND OTHER OBSTRUCTIONS WHICH WILL AFFECT THE WORK. AS PART OF THIS WORK THE CONTRACTOR SHALL PREPARE AN ACCURATE FIELD SURVEY OF THE LOCATION OF ALL STRUCTURAL
MEMBERS IN THE WORK AREA PRIOR TO BEGINNING SHOP DRAWINGS AND CONSTRUCTION. THIS
SURVEY SHALL BE SUBMITTED TO THE ARCHITECT WITH VARIANCES NOTED. CLAIMS FOR ADDITIONAL
TIME OR EXTRA COST DUE TO OBSTRUCTIONS AND VARIANCES IN THE LOCATION OF THE
STRUCTURAL MEMBERS WILL NOT BE HONORED AFTER WORK HAS BEGUN ON THE PROJECT.
BUILDING CODE: INTERNATIONAL BUILDING CODE, 2021 EDITION; INTERNATIONAL
EXISTING BUILDING CODE, 2021 EDITION
DEAD LOAD:
ANY CHANGES IN CONSTRUCTION MATERIALS FROM THOSE SHOWN ON
THE ARCHITECTURAL OR STRUCTURAL DRAWINGS SHALL BE REPORTED BY
THE CONTRACTOR TO THE STRUCTURAL ENGINEER FOR VERIFICATION OF
LOAD CARRYING CAPACITY OF THE STRUCTURE.
MECHANICAL WEIGHT OF AHU AS SHOWN ON DRAWINGS
LIVE LOAD:
ROOF: 20 PSF
LIVE LOAD REDUCTIONS HAVE BEEN APPLIED IN ACCORDANCE WITH THE
BUILDING CODE, UNLESS NOTED OTHERWISE.
WIND LOAD:
INTERNATIONAL BUILDING CODE, 2021 EDITION
VELOCITY (ULT) : 116 MPH THREE SECOND GUST
EXPOSURE: C
RISK CATEGORY: IV
INTERNAL PRESSURE COEFFICIENT, Gcpi: +/- 0.18
EFFECTIVE WIND AREA ft²
20 ft² 50 ft² 100 ft²
ZONE
2e
2r
+/- 45
ROOF DESIGN GROSS PRESSURES,
WIND ONLY (PSF)
+/- 50
+/- 70
+/- 40
+/- 35
+/- 50
+/- 35
+/- 30
+/- 35
EFFECTIVE WIND AREA ft²
20 ft² 50 ft² 100 ft²
ZONE
+/- 40
WALL DESIGN GROSS PRESSURES,
WIND ONLY (PSF)
+/- 45
+/- 35
+/- 40
+/- 35
+/- 40 a = 4'-4"
SEISMIC LOAD:
RISK CATEGORY: IV
SEISMIC IMPORTANCE FACTOR (I): 1.5
MAPPED SPECTRAL RESP ACCEL (Ss/S1): 0.093g/0.053g
SITE CLASS: D (DEFAULT)
SPECTRAL RESPONSE COEFF (Sds/Sd1): 0.099g/0.085g.
SEISMIC DESIGN CATEGORY: C
SEISMIC FORCE RESISTING SYSTEM: SAME AS EXISTING
DESIGN BASE SHEAR: SAME AS EXISTING
SEISMIC RESPONSE COEFF (Cs): SAME AS EXISTING
RESPONSE MODIFICATION COEFFICIENT (R): SAME AS EXISTING
ANALYSIS PROCEDURE USED: N/A SEISMIC CHECK NOT REQUIRED
SNOW LOAD:
GROUND SNOW LOAD (Pg): 5 PSF FLAT ROOF SNOW LOAD (Pf): 4.2 PSF SNOW EXPOSURE FACTOR (Ce): 1.0
SNOW LOAD IMPORTANCE FACTOR (I): 1.2
THERMAL FACTOR (Ct): 1.0
3 +/- 60 +/- 35 +/- 35 a a a a
2r
2r
2r
5 5
2e
2e
2e
2e
2r
WOOD FRAMING
1. LUMBER AND ITS FASTENINGS SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATIONS FOR
WOOD CONSTRUCTION, LATEST EDITION.
2. ALL WOOD FRAMING SIZES, FRAMING, FASTENING REQUIREMENTS, ANCHORAGES, FIRESTOPS, AND CONNECTORS NOT SHOWN ON THESE PLANS TO BE PER THE SPECIFIED BUILDING CODE.
WOOD FRAMING SIZES SHOWN ARE THE MINIMUM REQUIRED STRUCTURALLY; COORDINATE WITH
OTHER DISCIPLINES FOR FURTHER DEPTH REQUIREMENTS FOR NON-STRUCTURAL PURPOSES.
3. ALL STRUCTURAL LUMBER TO BE STRUCTURAL GRADE NO. 2 SOUTHERN PINE WITH A MAXIMUM
MOISTURE CONTENT OF 19%. ALL LUMBER TO BE STAMPED WITH THE GRADE MARK OF AN
APPROVED GRADING AGENCY.
4. ALL WOOD FRAMING EXPOSED TO WEATHER SHALL BE PRESSURE-TREATED. ALL FASTENERS IN
CONTACT WITH PRESSURE-WOOD TO BE HOT DIP GALVANIZED PER THE MANUFACTURERS
RECOMMENDATIONS AND THE APPLICABLE BUILDING CODE. ALL STRUCTURAL COLUMNS TO BE
HELD 1" ABOVE THE SLAB BY A SPECIFIED OR APPROVED CONNECTION DEVICE.
5. THE FRAMING LAYOUTS DEPICTED ON THE PLANS ARE TO ILLUSTRATE GENERAL FRAMING
CONDITIONS BUT DO NOT NECESSARILY DEPICT THE CORRECT QUANTITIES OR CONNECTIONS
REQUIRED.
6. FASTENING FOR ALL STRUCTURAL MEMBERS NOT SPECIFICALLY SHOWN IN THE PLANS TO BE PER
THE FASTENING SCHEDULE OF THE APPLICABLE BUILDING CODE.
7. BOLTS SHALL CONFORM TO ASTM A307, ANSI D18.2.1. SCREWS AND LAG SCREWS SHALL CONFORM TO ANSI B18.2.1. AND ANSI B18.6.1, RESPECTIVELY. BOLTS THROUGH WOOD SHALL BE FITTED WITH
STANDARD WASHERS.
8. BOLT HOLES SHALL BE AT LEAST A MINIMUM DIAMETER OF 1/32" AND NO MORE THAN A MAXIMUM
OF 1/16" LARGER THAN THE BOLT DIAMETER.
9. BOLT NUTS SHALL BE FINGER-TIGHT PLUS 1/3 TO 1/2 TURN WITH A HAND WRENCH, WITH
CONSIDERATION GIVEN TO POSSIBLE FUTURE WOOD SHRINKAGE. CARE SHOULD BE TAKEN NOT
TO OVER-TORQUE THE NUT. IMPACT WRENCHES SHOULD NOT BE USED AS THEY MAY PRELOAD
THE CONNECTORS. BOLT NUTS SHALL BE PERIODICALLY RETIGHTENED.
10. UNLESS OTHERWISE NOTED, CONNECTORS SHALL BE INSTALLED WITH THE MAXIMUM NUMBER AND SIZE OF FASTENERS AS REQUIRED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
11. THE NUMBER AND SIZE OF NAILS USED TO CONNECT WOOD MEMBERS SHALL BE ACCORDING TO
THE APPLICABLE BUILDING CODE. REFER TO MANUFACTURER FOR NAILING REQUIREMENTS (TO
ATTAIN MAXIMUM TABLE VALUES) FOR ALL WOOD-TO-WOOD MECHANICAL FASTENERS.
12. FOR OVERLAY FRAMING AT ROOF OR OTHER CONVENTIONAL ROOF FRAMING, CONTRACTOR SHALL PROVIDE 2X FRAMING TO MATCH EXISTING FRAMING OR BE IN ACCORDANCE WITH ROOF RAFTER
TABLES IN THE APPLICABLE BUILDING CODE.
13. DECKING SHALL BE INSTALLED USING A RANDOM LAY UP PATTERN.
14. PLYWOOD ROOF DECKING SHALL BE APA RATED CD INTERIOR WITH EXTERIOR GLUE, THICKNESS
TO MATCH EXISTING. INSTALL PLYWOOD WITH FACE GRAIN ACROSS SUPPORTS. PROVIDE
PLYWOOD SHEATHING CLIPS AT ALL FREE EDGES. PLYWOOD SPAN RATING SHALL MATCH EXISTING OR BE A MIN OF 32/16. NAIL PLYWOOD TO FRAMING TO MATCH EXISTING OR WITH 10d HOT-DIP
GALVANIZED NAILS UNLESS NOTED OTHERWISE AS FOLLOWS:
• ROOF ZONE: FIRST 5’-0” OF GABLED END FIRST 4’-0” FROM EDGE AND RIDGE
• PANEL EDGES 4” OC 6” OC
• PANEL FIELD 6” OC 6” OC
• NAIL TO ALL SUPPORTS AT 4” OC FOR 10’-0” SQUARE ARE AT CORNERS.
CONCRETE
1. ALL CONCRETE REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60, EXCEPT WHERE NOTED. NO. 3 BARS SHALL CONFORM TO ASTM A615, GRADE 40. DEFORMED BAR ANCHORS SHALL
CONFORM TO ASTM A496, GR 70.
2. ALL WELDED WIRE FABRIC SHALL BE SMOOTH WIRE FABRIC CONFORMING TO ASTM A1064, AND
SHALL BE FURNISHED IN FLAT SHEETS ONLY. ROLLED WIRE FABRIC WILL BE REJECTED.
3. CONCRETE IN THE FOLLOWING AREAS SHALL HAVE SAND AND CRUSHED CARBONATE AGGREGATE
CONFORMING TO ASTM C33, TYPE 1 PORTLAND CEMENT, FLYASH CONFORMING TO ASTM C618,
CLASS ‘C’ UP TO 20 PERCENT REPLACEMENT BY VOLUME AND THE FOLLOWING DESIGNATED
COMPRESSIVE STRENGTH (f’c) IN 28 DAYS:
• ALL OTHER CONCRETE ---- 4000 PSI (w/c = 0.50 MAX)
• CONCRETE SUPPLIER SHALL BE AWARE OF CEMENTS THAT CAN CAUSE
ETTRINGITE FORMATION IN THE CEMENT PASTE AND BE PREPARED TO SHOW
THAT THE CEMENTS USED WILL NOT CAUSE THIS PROBLEM.
4. CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE AS FOLLOWS; SEE SEC. 7.7 ACI 318, LATEST EDITION FOR CONDITIONS NOT NOTED, PROVIDE CHAIR SUPPORTS (AZTEC CASTLE CHAIR, WHC SERIES ‘B’ OR EQUAL) TO ADEQUATELY SUPPORT BARS FOR PROPER CLEARANCE AS
RECOMMENDED BY THE AMERICAN CONCRETE INSTITUTE AND THE CONCRETE REINFORCING
STEEL INSTITUTE. SLAB ON GRADE REINFORCEMENT SHALL BE SUPPORTED AT 45-INCH MAXIMUM
INTERVALS OR EVERY THIRD BAR.
5. DETAILING OF CONCRETE REINFORCEMENT AND ACCESSORIES SHALL BE IN ACCORDANCE WITH
ACI PUBLICATION 315, LATEST EDITION. ALL HOOKED BARS SHOWN IN DETAILS SHALL HAVE
STANDARD HOOKS UNLESS NOTED OTHERWISE.
6. ALL MIXING, TRANSPORTING, PLACING AND CURING OF CONCRETE SHALL BE DONE IN
ACCORDANCE WITH THE RECOMMENDATIONS OF THE AMERICAN CONCRETE INSTITUTE, ACI 301,
LATEST EDITION.
7. NO HORIZONTAL JOINTS WILL BE PERMITTED IN CONCRETE EXCEPT WHERE THEY NORMALLY
OCCUR OR WHERE NOTED. VERTICAL JOINTS SHALL OCCUR AT CENTER SPANS OR AT LOCATIONS
APPROVED BY THE STRUCTURAL ENGINEER.
8. REINFORCING BARS SHALL NOT BE WELDED WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER.
9. CONDUITS ARE NOT ALLOWED IN SLABS, BEAMS, WALLS OR COLUMNS. ALL CONDUITS SHALL BE
SUSPENDED FROM OR ATTACHED TO THE CONCRETE STRUCTURE.
10. PROVIDE (1) - #5 X 4’-0” AT RE-ENTRANT CORNERS AND AROUND RECTANGULAR HOLES IN SLABS
UNLESS NOTED OTHERWISE. PLACE BAR DIAGONAL TO CORNER WITH 1” CLEARANCE FROM TOP
AND THE SIDE OF THE SLAB AT THE CORNER.
11. WHERE FRESH CONCRETE IS DEPOSITED AGAINST HARDENED CONCRETE (GREATER THAN 8
HOURS OLD), CLEAN EXISTING SURFACE OF LAITANCE AND FOREIGN MATERIAL AND DAMPEN THE
EXISTING SURFACE. IF REQUIRED, ROUGHEN EXISTING CONCRETE TO ¼” AMPLITUDE.
th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t
00 00
11 11 o n e in c h o n e fo o t o n e in c h o n e fo o t o n e in c h o n e fo o t o n e in c h o n e fo o t
00 00
22 22 th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
00 00 22 22 o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t
00 00 44 44 th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t
00 00 44 44 o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
00 00 44 44
88 88 o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
00 00 44 44
88 88
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 09/30/2021
ENGR REG. NO. EXP. 02/28/2022
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
TEXAS FIRM REGISTRATION NO. 8856
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
PARTIALLY SPRINKLERED
ENVIRONMENTAL ENGINEER
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
TX BR2171,
TX F-17591,
Drawing Number
Building Number
09/14/2021
/9
/2
:2
:4
P
M
STRUCTURAL GENERAL NOTES
ZAFSJB
BID DOCUMENTS
BUILDING 6 COVID-19 BUILD
BACK WITH HVAC
09/14/2021
549-21-400
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD.
DALLAS, TX 75216
SA001
STRUCTURAL ABBREVIATIONS
+/- PLUS OR MINUS
ADDNL ADDITIONAL
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ARCH ARCHITECT OR ARCHITECTURAL
B/W BETWEEN
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BOD BOTTOM OF DECK
BOS BOTTOM OF STEEL
CF COLD FORMED
CFMF COLD-FORMED METAL FRAMING
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLR CLEAR/CLEARANCE
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONT CONTINUOUS
CTR CENTER
db DIA OF REINF BAR, DIA OF BOLT
DBA DEFORMED BAR ANCHOR
DBL DOUBLE
DIA DIAMETER
DIAG DIAGONAL
DWL DOWEL
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
EOD EDGE OF DECK
EOS EDGE OF SLAB
EQ EQUAL
EW EACH WAY
EXIST EXISTING
EXT EXTERIOR
FLR FLOOR
FND FOUNDATION
FS FAR SIDE
FTG FOOTING
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
HORIZ HORIZONTAL
HSA HEADED STUD ANCHOR
HSS HOLLOW STRUCTURAL SECTION
IF INSIDE FACE
INT INTERIOR
JST JOIST
K KIPS (1000 LBS)
LCE COMPRESSION EMBEDMENT LENGTH
LCS COMPRESSION LAP SPLICE LENGTH
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LTE TENSION EMBEDMENT LENGTH
LTS TENSION LAP SPLICE LENGTH
LW LIGHTWEIGHT
MANUF MANUFACTURER
MTL METAL
NIC NOT IN CONTRACT
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OCEW ON CENTER, EACH WAY
OF OUTSIDE FACE
OH OPPOSITE HAND
OPP OPPOSITE
PAF POWDER ACTUATED FASTENER
PEMB PRE-ENGINEERED METAL BUILDING
PL PLATE
PLF POUNDS PER LINEAL FOOT
PREFAB PREFABRICATED
PRELIM PRELIMINARY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
RE: OR REF REFER TO
REINF REINFORCING
REQD REQUIRED
SIM SIMILAR
SLV SHORT LEG VERTICAL
SOG SLAB ON GRADE
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
SW SHEAR WALL
SYM SYMMETRIC
T&B TOP AND BOTTOM
TOC TOP OF CONCRETE
TOD TOP OF DECK
TOS TOP OF STEEL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
W/ WITH
W/O WITHOUT
WF WIDE FLANGE
WP WORK POINT
WWF WELDED WIRE FABRIC
STIRRUP AND TIE HOOK
#3
#4
#5
BAR
SIZE
1 ½
2 ½
4 ½
5 ½
D= INSIDE DIAMETER OF BEND
6db FOR #3, #4, #5
12db FOR #6, #7, #8
D E
T A
IL
IN
G D
IM
E
N S
IO
N
D
A OR G
db
D
D E
T A
IL
IN
G D
IM
E
N S
IO
N
A O
R G
H O
O K
AND SM
ALLER
6db FOR #8 BARS
D
D db
90° HOOK
135° HOOK
CORNER CONDITIONS-STIRRUP OR TIE
90° HOOK
90° HOOK
BEYOND
135° HOOK
90° HOOK
BEYOND
135° HOOK
135° HOOK
90° HOOK
135° HOOK
GROSS TIE
D
(INCHES)
90° HOOK
A OR G
(INCHES)
135° HOOK
A OR G
(INCHES)
4 ½
#3
#4
#5
#6
#7
#8
#9
BAR
fc=3000PSI
0.7 Lhb
25 18
#10 28 20
#11 31 22
Lhb
NOTES:
1. Ldh = DEVELOPMENTAL LENGTH OF STANDARD HOOKS IN TENSION (INCHES).
2. Ldh = Lhb UNLESS CONDITIONS OF 3 SATISFIED.
3. Ldh + 0.7 Lhb FOR #11 BARS AND SMALLER WHEN SIDE COVER (NORMAL TO PLANE OF HOOK)
IS NOT LESS THAN 2 1/2 INCHES AND FOR 90 DEGREE HOOKS COVER ON BAR EXTENSION
BEYOND HOOK IS NOT LESS THAN 2 INCHES.
4. HOOKS ARE NOT CONSIDERED EFFECTIVE FOR DEVELOPING BAR IN COMPRESSION.
5. Ldh SHALL BE MULTIPLIED BY 1.2 FOR EPOXY-COATED HOKKED REINFORCEMENT BARS.
#14 38 --
#18 50 --fc=4000PSI
0.7 Lhb
22 16
25 18
27 19
Lhb
33 --
43 --fc=5000PSI
0.7 Lhb
20 14
22 16
24 17
Lhb
29 --
39 --fc=6000PSI
0.7 Lhb
18 13
20 14
22 16
Lhb
27 --
35 --fc=7000PSI
0.7 Lhb
17 12
19 14
21 15
Lhb
25 --
33 --fc=8000PSI
0.7 Lhb
16 12
18 13
19 14
Lhb
23 --
31 --
#3
#4
#5
#6
#7
#8
#9
BAR
#10
#11
#14
#18
SIZE SIZE
DEVELOPMENT LENGTHS OF STANDARD HOOKS IN TENSION
GRADE 60 REINFORCEMENT, NORMAL CONCRETE
90 DEGREE HOOKS
Ldh
180 DEGREE HOOKS
Ldh
OUTSIDE FACE
OF BAR
OUTSIDE FACE
OF BAR
DEVELOPMENT AND LAP SPLICE SCHEDULE
#3
#4
#5
#6
#7
#8
#9
BAR
F'c = 3000 psi
EMBEDMENT
8 21
COMPR TENSION (LTE)
OTHER
LAP SPLICE
(LCS) TOP
COMPR TENSION (LTS)
OTHER
HOOK
(LDH)
16 12 28 21 6
22 15 37 28 8
27 19 46 36 10
33 23 56 43 12
48 26 81 62 13
55 30 93 71 15
80 62 34 105 80 17
F'c = 4000 psi
EMBEDMENT
(LCE) TOP
COMPR TENSION (LTE)
OTHER
LAP SPLICE
(LCS) TOP
COMPR TENSION (LTS)
OTHER
HOOK
(LDH)
18 14 12 24 18 6
25 19 15 32 25 7
31 24 19 40 31 8
37 28 23 48 37 10
54 42 26 70 54 12
62 47 30 80 62 13
70 54 34 91 70 15
(LCE)
#10 90 70 38 118 90 19 24 78 60 38 102 78 17
#11 100 77 42 131 100 22 27 87 67 42 113 87 1931
TOP
NOTES (GENERAL):
1. STAGGER ALL SPLICES 12 db MIN, BUT NOT LESS THAN 12"
2. ALL DIMENSIONS INDICATED IN TABLE ARE IN INCHES
3. BARS GREATER THAN #11 SHALL BE MECHANICALLY SPLICED
4. ALL SPLICES SHALL BE WIRED IN CONTACT STACKED VERTICAL.
MULTIPLIERS:
ALL EMBEDMENT AND LAP SPLICE LENGTHS SHALL BE INCREASED
AS REQ'D BY THE MULTIPLIERS BELOW. APPLY MULTIPLE
MULTIPLIERS IF APPLICABLE.
1.3 -- IF CONC CONTAINS LIGHT WEIGHT AGGREGATES
1.3 -- IF EPOXY COATED REBAR USED
NOTES (PERTAINING TO TABLE):
1. TOP BARS ARE HORIZONTAL BARS THAT HAVE MORE THAN 12" OF
FRESH CONCRETE CAST BELOW THEM.
2. ALL BARS THAT ARE NOT "TOP BARS" ARE "OTHER" BARS
3. ABBREVIATIONS:
- LCE - COMPRESSION EMBEDMENT LENGTH
- LTE - TENSION EMBEDMENT LENGTH
- LCS - COMPRESSION LAP SPLICE LENGTH
- LTS - TENSION LAP SPLICE LENGTH
- LDH - HOOKED BAR TENSION EMBEDMENT LENGTH
END HOOK DIMENSIONS
#3
#4
#5
#6
#7
#8
#9
#10
#11
BAR
SIZE
#14
#18
FINISHED
BEND
DIAMETER D,
(INCHES)
180 ° HOOKS
A OR G'
(INCHES)
A OR G'
(INCHES)
J, (INCHES)
2 ¼
3 ¾
4 ½
5 ¼
9 ½
10 ¾
18 ¼
11 ¾
13 ¼
14 ¾
21 ¾
28 ½
90° HOOK
D= INSIDE DIAMETER OF BEND
d b
D
A O
R G db
DETAILING DIMENSION
90° HOOK
2 1/2" MIN
4db OR
D
DIMENSION
DETAILING
A OR G
HOOK
J db
180° HOOK
MATCH EXISTING
PAD DEPTH AND
REINFORCEMENT
#4 DOWEL @ 12" OC (EMBED 6" MIN
INTO EXISTING SLAB USING HILTI
HY-200 ANCHORAGE SYSTEM.
(INSTALL PER MANUFACTURER'S
RECOMMENDATIONS.)
EXISTING PAD AND
REINFORCEMENT
EXISTING ATTIC
FLOOR SLAB
NOTES:
• USE DETAIL AS REQUIRED
• USE WITH DETAIL /6 SA030
CONTRACTOR TO ROUGHEN
SURFACE PER GENERAL NOTES
¾" CHAMFER, TYPICAL
BOTTOM REINFORCEMENT,
WHERE SCHEDULED
TOP REINFORCEMENT,
REFER TO SCHEDULE
(1) - #4 CONTINUOUS AT
PERIMETER WITH (1) - #4X4'-0"
AT EXTERIOR CORNERS
AND (1) - #4X4'-0" DIAGONAL AT
RE-ENTRANT CORNERS
REFER TO NOTE 1
2'-0"
2' -0
2" 4'- 0"
RE-ENTRANT
CORNERS
EXTERIOR
CORNERS
HOUSEKEEPING PAD REINFORCEMENT SCHEDULE
PAD THICKNESS
TOP
REINFORCEMENT
BOTTOM
REINFORCEMENT
T-4" WWR 4x4-W2.9xW2.9 OR #3@12" EACH WAY NONE
4"< T< = 6"
6" < T < = 8"
8" < T < = 12"
WWR 4x4-W4xW4 OR #4@18" EACH WAY
WWR 4x4-W6xW6 OR #4@12" EACH WAY
#4@18" EACH WAY
NONE
NONE
#4@18" EACH WAY
NOTE:
1. REFER TO ARCHITECTURAL, STRUCTURAL, OR MEP DRAWING FOR HOUSEKEEPING PAD
PLAN DIMENSIONS AND THICKNESS (4" MINIMUM THICKNESS).
2. CONTRACTOR SHALL COORDINATE DIMENSIONS AND OTHER SPECIAL REQUIREMENTS
WITH EQUIPMENT MANUFACTURERS AND PROVIDE WHERE REQUIRED WHETHER SHOWN
ON STRUCTURAL DRAWING OR NOT.
3. PROVIDE ADDITIONAL LAYER OF REINFORCING FOR PAD THICKNESS GREATER THAN 18".
CONTRACTOR TO ROUGHEN
SURFACE PER GENERAL NOTES
NTS1
TYPICAL STIRRUP AND TIE HOOK TYPES
NTS2
SPLICE & DEVELOPMENT SCHEDULE FOR HOOKS
NTS3
SPLICE & DEVELOPMENT SCHEDULE
NTS4
TYPICAL END HOOK TYPES
NTS5
HOUSEKEEPING PAD EXTENSION
NTS6
TYPICAL HOUSEKEEPING PAD OVER SLAB ON GRADE
th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t
00 00
11 11 o n e in c h o n e fo o t o n e in c h o n e fo o t o n e in c h o n e fo o t o n e in c h o n e fo o t
00 00
22 22 th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
00 00 22 22 o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t
00 00 44 44 th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t
00 00 44 44 o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
00 00 44 44
88 88 o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
00 00 44 44
88 88
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 09/30/2021
ENGR REG. NO. EXP. 02/28/2022
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
TEXAS FIRM REGISTRATION NO. 8856
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
PARTIALLY SPRINKLERED
ENVIRONMENTAL ENGINEER
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
TX BR2171,
TX F-17591,
Drawing Number
Building Number
09/14/2021
/9
/2
:2
:5
P
M
TYPICAL DETAILS - CONCRETE
ZAFSJB
BID DOCUMENTS
BUILDING 6 COVID-19 BUILD
BACK WITH HVAC
09/14/2021
549-21-400
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD.
DALLAS, TX 75216
SA030
A
B
C
D
23459 8 7 6
21' - 6" 12' - 4" 12' - 10" 6' - 5 1/2" 6' - 5 1/2" 12' - 10" 12' - 4" 21' - 6"
/2
6'
/2
1'
1'
EXISTING CS1 BMSEXISTING CS3 BMS
EXISTING CS2 BMS
EXISTING CS3 BMS
EXISTING CS4 BMS
EXISTING CS1 BMS
EXISTING CS1 BMS
EXISTING CS2 BMS
EXISTING CS1 BMS
EXISTING CB5 BM EXISTING CB6 BM EXISTING CB7 BM
EXISTING CB8 BM
EXISTING CB5 BM EXISTING CB6 BM EXISTING CB7 BM
EXISTING CB8 BM
EXISTING CB6 BM
EXISTING CB6 BM
EXISTING CB7 BM
EXISTING CB7 BM
EXISTING CB8 BM
EXISTING CB8 BM
E X
IS
T
IN
G
C B
B
M E
X
IS
T
IN
G C
B
B M
E X
IS
T
IN
G
C
B
B M
E X
IS
T
IN
G
C B
B
M E
X
IS
T
IN
G C
B
B M
E X
IS
T
IN
G
C
B
B
M 6-AHU-3
6-AHU-4
6-AH-56-AHU-2
7" 16' - 2" 14' - 6" 17' - 6" 8' - 9" 17' - 6" 14' - 6" 16' - 2"
1 1 1 1
WEIGHT 1,727 LBS
WEIGHT 1,727 LBS
WEIGHT 1,899 LBS
WEIGHT 2,105 LBS
# ATTIC PLAN NOTES:
1. CONTRACTOR TO REFERENCE THE MEP SET FOR EXACT LOCATIONS AND SIZE
OF THE AHU. LOCATIONS OF AHUS SHALL BE CLOSE TO WHAT IS SHOWN ON
PLAN.
GENERAL SHEET NOTES
A. REFERENCE SHEET SA-001 FOR STRUCTURAL GENERAL NOTES AND SA-030 FOR
TYPICAL STRUCTURAL DETAILS. REVIEW NOTES & DETAILS FOR APPLICABILITY.
B. SEE ARCHITECTURAL DRAWING FOR DETAILS & DIMENSIONS NOT SHOWN.
C. ALL EXISTING CONDITIONS, ELEVATIONS, AND DIMENSIONS SHOWN ARE TAKEN
FROM THE EXISTING CONSTRUCTION PLANS DATED NOVEMBER 17, 1938.
CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS, ELEVATIONS, AND
DIMENSIONS AND NOTIFY THE CONTRACTING OFFICER OF ALL DISCREPANCIES
PRIOR TO COMMENCING THE WORK.
D. IT IS THE CONTRACTOR'S RESPONSIBILITY TO SHORE ANY EXISTING
STRUCTURE IN A MANNER AS NEEDED THAT WILL PREVENT FAILURE OR
DAMAGE TO THE EXISTING STRUCTURE.
E. CONTRACTOR TO PROVIDE TEMPORARY COVERS (SUCH AS SHEETING, TARPS,
OR OTHER PROTECTIVE MATERIALS) ON THE EXISTING BUILDING IN ORDER TO
PROTECT THE REMAINING INTERIOR PORTION OF THE BUILDING FROM
WEATHER AND ELEMENTS AT ALL TIMES DURING CONSTRUCTION.
th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t
00 00
11 11 o n e in c h o n e fo o t o n e in c h o n e fo o t o n e in c h o n e fo o t o n e in c h o n e fo o t
00 00
22 22 th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
00 00 22 22 o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t
00 00 44 44 th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t
00 00 44 44 o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
00 00 44 44
88 88 o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
00 00 44 44
88 88
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 09/30/2021
ENGR REG. NO. EXP. 02/28/2022
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
TEXAS FIRM REGISTRATION NO. 8856
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
PARTIALLY SPRINKLERED
ENVIRONMENTAL ENGINEER
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
TX BR2171,
TX F-17591,
Drawing Number
Building Number
09/14/2021
/9
/2
:2
:5
P
M
EXISTING ATTIC FRAMING PLAN
ZAFSJB
BID DOCUMENTS
BUILDING 6 COVID-19 BUILD
BACK WITH HVAC
09/14/2021
549-21-400
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD.
DALLAS, TX 75216
SF101
1/4" = 1'-0"
EXISTING ATTIC FRAMING PLAN
A
B
C
D
23459 8 7 6
2' - 1"4' - 9" 2' - 7" 2' - 1" 2' - 7" 4' - 9"
W 6X12
EXIST (TYP)
W
X
W
X .5
W
X
W
X .5
W
X
W
X
W
X .5
W
X
W
X .5
W
X
W12X19
W12X19
E X
IS
T
E X
IS
T
E X
IS
T
E X
IS
T
E X
IS
T
E X
IS
T
E X
IS
T
E X
IS
T
E X
IS
T
E X
IS
T
EXIST
EXIST
/2
6'
/2
2'
2'
21' - 6" 12' - 4" 12' - 10" 6' - 5 1/2" 6' - 5 1/2" 12' - 10" 12' - 4" 21' - 6"
# ROOF SUBSTRUCTURE PLAN NOTES:
1. NO CHANGE TO EXISTING STRUCTURE AT THIS LEVEL
GENERAL SHEET NOTES
A. REFERENCE SHEET SA-001 FOR STRUCTURAL GENERAL NOTES AND SA-030 FOR
TYPICAL STRUCTURAL DETAILS. REVIEW NOTES & DETAILS FOR APPLICABILITY.
B. SEE ARCHITECTURAL DRAWING FOR DETAILS & DIMENSIONS NOT SHOWN.
C. ALL EXISTING CONDITIONS, ELEVATIONS, AND DIMENSIONS SHOWN ARE TAKEN
FROM THE EXISTING CONSTRUCTION PLANS DATED NOVEMBER 17, 1938.
CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS, ELEVATIONS, AND
DIMENSIONS AND NOTIFY THE CONTRACTING OFFICER OF ALL DISCREPANCIES
PRIOR TO COMMENCING THE WORK.
D. IT IS THE CONTRACTOR'S RESPONSIBILITY TO SHORE ANY EXISTING
STRUCTURE IN A MANNER AS NEEDED THAT WILL PREVENT FAILURE OR
DAMAGE TO THE EXISTING STRUCTURE.
E. CONTRACTOR TO PROVIDE TEMPORARY COVERS (SUCH AS SHEETING, TARPS,
OR OTHER PROTECTIVE MATERIALS)…
This is the start of the file's text. The full file is on GovTribe.