Lab Report.docx
DOCX document 40 KB Posted
- Attached to
- Blast Grit Disposal
- Solicitation number
- 52090PR250000028
About this file
This document is an Analytical Report from Acculab, an analytical laboratory, regarding test results for a sand blast grit sample. The report provides details on the analysis of TCLP (Toxicity Characteristic Leaching Procedure) metals testing performed on the sample, including results for arsenic, barium, cadmium, chromium, lead, selenium, silver, and mercury. The report includes quality control information such as method reporting limits, percent recoveries, and relative percent differences.
The related federal contract opportunity is a Solicitation from the U.S. Coast Guard for Sand Blast Grit Disposal, with a response due date of 11/18/2024. The Solicitation Number is 52090PR250000028, and the Contracting Officer is SKCS Justin Hinkle. Interested parties are requested to provide a quote on SF-18.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Pacific Commercial Services INC.pdf | ||
| SOW - Grit disposal_updated.docx | DOCX document | |
| 15-5689 wage rates.txt | TXT text file | |
| SOW - Grit disposal.docx | DOCX document | |
| SF-18.doc | DOC document | |
| Combined Synopsis Notice.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Analytical Report
Client
Advanced Analytical Laboratory
| Acculab WO# |
| 24-AL0817-4 |
544 Ohohia Street #10
Honolulu, HI, 96819
| Date Sampled |
| 7/29/2024 |
Project Manager
Uwe Baumgartner/ Elisa Young
| Date Received |
| 8/17/2024 |
Project Name
Sand Blast Grit
| Date Reported |
| 8/22/2024 |
Client Project#
#1
Project#
Z701
Metals in Solid TCLP by EPA 6020B/3010A/1311
Accu Lab Batch# AL081724-10
TCLP
TCLP
Client sample ID
| SBG-01 |
| MS |
| MSD |
| RPD |
| Lab ID |
| MRL |
| Unit |
| MTH BLK |
| LCS |
| 24-AL0817-4-1 |
| 24-AL0817-2-1 |
| 24-AL0817-2-1 |
| 24-AL0817-2-1 |
Matrix
| TCLP Extract |
| TCLP Extract |
| TCLP Extract |
| TCLP Extract |
| TCLP Extract |
| TCLP Extract |
Date Extracted
| 8/17/2024 |
| 8/17/2024 |
| 8/17/2024 |
| 8/17/2024 |
| 8/17/2024 |
| 8/17/2024 |
Date Analyzed
| 8/18/2024 |
| 8/18/2024 |
| 8/18/2024 |
| 8/18/2024 |
| 8/18/2024 |
| 8/18/2024 |
Arsenic (As)
0.05 mg/l nd
104% nd
102%
94%
8%
| Barium (Ba) |
| 0.50 |
| mg/l |
| nd |
| 106% |
| 1.3 |
| 103% |
| 98% |
| 2% |
| Cadmium (Cd) |
| 0.05 |
| mg/l |
| nd |
| 102% |
| nd |
| 96% |
| 89% |
| 8% |
| Chromium (Cr) |
| 0.20 |
| mg/l |
| nd |
| 93% |
| nd |
| 92% |
| 89% |
| 3% |
| Lead (Pb) |
| 0.05 |
| mg/l |
| nd |
| 99% |
| nd |
| 93% |
| 88% |
| 6% |
| Selenium (Se) |
| 0.05 |
| mg/l |
| nd |
| 114% |
| nd |
| 117% |
| 109% |
| 7% |
| Silver (Ag) |
| 0.05 |
| mg/l |
| nd |
| 96% |
| nd |
| 110% |
| 98% |
| 11% |
| Mercury (Hg) |
| 0.05 |
| mg/l |
| nd |
| 90% |
| nd |
| 82% |
| 84% |
| 2% |
Acceptable Recovery Limits:
| LCS |
| 80-120% |
| MS/MSD |
| 75-125% |
| Acceptable RPD limit: |
| 20% |
12524 130th Lane NE Kirkland WA 98034 Tel: (425) 214-5858
(425) 214-5868 Email: lisa@accu-lab.com website: www.accu-lab.com
This report is issued solely for the use of the person or company to whom it is addressed.
Any use, copying or disclosure other than by the intended recipient is unauthorized.
Analytical Report
| Client |
| Advanced Analytical Laboratory |
| Acculab WO# |
| 24-AL0817-4 |
544 Ohohia Street #10
| Honolulu, HI, 96819 |
| Date Sampled |
| 7/29/2024 |
| Project Manager |
| Uwe Baumgartner/ Elisa Young |
| Date Received |
| 8/17/2024 |
| Project Name |
| Sand Blast Grit |
| Date Reported |
| 8/22/2024 |
| Client Project# |
| #1 |
| Project# |
| Z701 |
Data Qualifiers and Comments:
Results reported on dry-weight basis for Solid samples.
| MRL- |
| Method Reporting Limit |
| nd- |
| Indicates the analyte is not detected at the listing reporting limit. |
| C- |
| Coelution with other compounds. |
| M- |
| % Recovery of surrogate, MS/MSD is out of the acceptable limit due to matrix effect. |
| B- |
| Indicates the analyte is detected in the method blank associated with the sample. |
| J- |
| The analyte is detected at below the reporting limit. |
| E- |
| The result reported exceeds the calibration range, and is an estimate. |
| D- |
| Sample required dilution due to matrix. Method Reporting Limits were elevated due to dilutions. |
| H- |
| Sample was received or analyzed past holding time |
| Q- |
| Sample was received with head space, improper preserved or above recommended temperature. |
| I- |
| Due to insufficient sample, LCS/LCS DUP were analyzed in place of MS/MSD. |
| R- |
| The recovery of this analyte in QC sample failed high, but the analyte was not detected in all related |
samples. No action was taken.
| R-1- |
| The RPD value for the MS/MSD was outside of QC acceptance limits however both recoveries were acceptable. All related samples were "nd". No action was taken. |
| R-2- |
| The recovery of the surrogate in sample failed high, but all related analytes were not detected in the |
sample. No action was taken.
image1.jpeg
File details come from the government source that posted it. Updated .