511.22358.TAP DMVA CONSTRUCT MOTOR VEHICLE STORAGE BUILDING - CALUMET MECHANICAL BID SET.pdf
PDF 244 KB Posted
- Solicitation number
- RFQ - 171 - 240000000401
- Issued by
- Houghton County, Capac Village, Michigan
About this file
This document appears to be a set of mechanical and plumbing drawings and specifications for the construction of a motor vehicle storage building at the Calumet Armory for the Michigan Department of Military and Veterans Affairs (DMVA). The project involves the design and construction of the building, including the installation of HVAC systems, plumbing, and fire protection. The drawings provide details on the piping, ductwork, and equipment to be installed, as well as the sequence of operations for the CO/NO2 detection and exhaust system. The related state and local contract opportunity indicates that this project is located in Houghton County and Capac Village, Michigan, and bids are being solicited for the construction work. The bid attachments must be submitted through the SIGMA VSS system, and any questions should be directed to the project contact, Aaron Janke, at UPEA.
The drawings and specifications do not provide pricing information, set-asides, or funding details. However, the contract opportunity indicates that this is a state and local government project, and the successful contractor will be required to comply with all applicable codes, regulations, and contract requirements. The contract term and any renewal options are not specified in the provided information.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STM
STM
PLUMBING PIPING MECHANICAL PIPING
DUCTWORK
CDS
CDR
CHWS
CHWR
CDS
CDR
CHWR
CHWS
AIR
ST
G
G
AIR
HWR
HWR
HWS
HWS
FP
FP
C
C
ST
V
V
SAN
HWC
SAN
EA24x14
EA24x14
EA24x14
HW
CW
HWC
OA24x14
OA24x14
OA24x14
RA24x14
SA24x14
SA24x14
S D
SA24x14
RA24x14
RA24x14
CW
HW
STM
CDR
CDS
CHWR
CHWS
HWR
HWS
G
AIR
FP
C
ST
CW
V
SAN
HWC
HW
HYDRONIC HOT WATER SUPPLY - NEW
HYDRONIC HOT WATER SUPPLY - EXISTING
HYDRONIC HOT WATER SUPPLY - DEMO
HYDRONIC HOT WATER RETURN - NEW
HYDRONIC HOT WATER RETURN - EXISTING
HYDRONIC HOT WATER RETURN - DEMO
COMPRESSED AIR - NEW
COMPRESSED AIR - EXISTING
COMPRESSED AIR - DEMO
GAS - NEW
GAS - EXISTING
GAS - DEMO
DOMESTIC COLD WATER - EXISTING
DOMESTIC COLD WATER - DEMO
DOMESTIC COLD WATER - NEW
DOMESTIC HOT WATER - EXISTING
DOMESTIC HOT WATER - DEMO
DOMESTIC HOT WATER - NEW
DOMESTIC HOT WATER RECIRC - EXISTING
DOMESTIC HOT WATER RECIRC DEMO
DOMESTIC HOT WATER RECIRC - NEW
SANITARY - EXISTING
SANITARY - DEMO
SANITARY - NEW
VENT - EXISTING
VENT - DEMO
VENT - NEW
STORM - EXISTING
STORM - DEMO
STORM - NEW
CONDENSATE - EXISTING
CONDENSATE - DEMO
CONDENSATE - NEW
FIRE PROTECTION - EXISTING
FIRE PROTECTION - DEMO
FIRE PROTECTION - NEW
ABBREVIATIONS
PIPING "T"
PIPING 90
STRAINER
SYMBOL LEGEND
CAP
NOTES
INLINE PUMP
BALANCE VALVE
PRESSURE RELIEF VALVE
3-WAY CONTROL VALVE
2-WAY CONTROL VALVE
GLOBE VALVE
GATE VALVE
CHECK VALVE
CIRCUIT SETTER
BUTTERFLY VALVE
BALL VALVE
EXHAUST AIR DUCT DOWN
EXHAUST AIR DUCT UP
RETURN AIR DUCT DOWN
RETURN AIR DUCT UP
SUPPLY AIR DUCT DOWN
SUPPLY AIR DUCT UP
AIR FLOW
HUMIDISTAT - 60" A.F.F.
THERMOSTAT - 60" A.F.F.
DUCT SMOKE DETECTOR
MOTORIZED DAMPER
FIRE / SMOKE DAMPER
(RATING DETERMINED BY WALL TYPE)
VOLUME CONTROL DAMPER
SQUARE TO ROUND TRANSITION
RETURN OR EXHAUST REGISTER
SUPPLY REGISTER
RELIEF AIR HOOD - ROOF
FRESH AIR INTAKE HOOD - ROOF
EXHAUST FAN - ROOF
RETURN OR EXHAUST AIR GRILLE
LINEAR DIFFUSER
SUPPLY AIR DIFFUSER PIPE BREAK
PIPE DOWN
PIPE UP
CLEAN OUT
GAS METER
UNION
HOSE BIBB
ELECTRIC BELL
SIAMESE CONNECTION
BARE FIN TUBE ELEMENT
FIN TUBE ELEMENT WITH COVER
EXTERNALLY INSULATED DUCTWORK
INTERNALLY LINED DUCTWORK
SUPPLY AIR DUCT - EXISTING
SUPPLY AIR DUCT - DEMO
SUPPLY AIR DUCT - NEW
RETURN AIR DUCT - EXISTING
RETURN AIR DUCT - DEMO
RETURN AIR DUCT - NEW
OUTSIDE AIR DUCT - EXISTING
OUTSIDE AIR DUCT - DEMO
OUTSIDE AIR DUCT - NEW
EXHAUST AIR DUCT - EXISTING
EXHAUST AIR DUCT - DEMO
EXHAUST AIR DUCT - NEW
CONDENSOR WATER SUPPLY
CONDENSOR WATER RETURN
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CONDENSOR WATER SUPPLY - DEMO
CONDENSOR WATER SUPPLY - EXIST
CONDENSOR WATER RETURN - DEMO
CONDENSOR WATER RETURN - EXIST
CHILLED WATER SUPPLY - DEMO
CHILLED WATER SUPPLY - EXIST
CHILLED WATER RETURN - DEMO
CHILLED WATER RETURN - EXIST
METER
STEAM - NEW
STEAM - EXISTING
STEAM - DEMO
CONNECTION TO EXISTING
ACCU AIR COOLED CONDENSING UNIT
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AI ANALOG INPUT
AO ANALOG OUTPUT
APD AIR PRESSURE DROP
AS AIR SEPERATOR
B BOILER
BB BASEBOARD
BC BOOSTER COIL
BDD BACKDRAFT DAMPER
BFG BELOW FINISHED GRADE
BFP BACKFLOW PREVENTER
BHP BRAKE HORSE POWER
BOD BOTTOM OF DUCT
BOP BOTTOM OF PIPE
BT BATH TUB
BTU BRITISH THERMAL UNITS
BTUH BRITISH THERMAL UNITS PER HOUR
C CONVECTOR
CA COMPRESSED AIR
CB CATCH BASIN
CC COOLING COIL
CCF 100 CUBIC FEET
CD CEILING DIFFUSER
CF CUBIC FEET
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CFP CLEAN OUT FERRULE AND PLUG
CH CHILLER
CI CAST IRON
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CO CLEAN OUT
CO CARBON MONOXIDE
COND CONDENSATE
CO2 CARBON DIOXIDE
CT COOLING TOWER
CU CONDENSING UNIT
CU FT CUBIC FOOT
CUH CABINET UNIT HEATER
CW COLD WATER
CWR CONDENSER WATER RETURN
CWS CONDENSER WATER SUPPLY
D DIFFUSER
DB DRY BULB
DEG F DEGREE FAHRENHEIT
DF DRINKING FOUNTAIN
DI DIGITAL INPUT
DIA DIAMETER
DN DOWN
DO DIGITAL OUTPUT
DWV DRAIN, WASTE AND VENT
EA EACH
EAT ENTERING AIR TEMPERATURE
EC ELECTRICAL CONTRACTOR
EF EXHAUST FAN
EG EXHAUST AIR GRILLE
ELEV ELEVATION
ER EXHAUST AIR REGISTER
EUH ELECTRIC UNIT HEATER
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EWT ENTERING WATER TEMPERATURE
EX EXISTING
EXH EXHAUST
F FURNACE
FAI FRESH AIR INTAKE
FBO FURNISHED BY OTHERS
FC FAN COIL
FD FLOOR DRAIN
FD FIRE DAMPER
FIN FIN TUBE RADIATION
FLG FLANGE
FP FIRE PROTECTION
FPM FEET PER MINUTE
FT FOOT OR FEET
F&T FLOAT AND THERMOSTATIC TRAP
G GAS (NATURAL)
GAL GALLON
GC GENERAL CONTRACTOR
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GT GREASE TRAP
H HYDROGEN
HB HOSE BIBB
HC HEATING COIL
HCO HORIZONTAL CLEANOUT
HP HORSE POWER
HTR HEATER
HVAC HEATING, VENTILATING & AIR COND
HW HOT WATER
HWC HOT WATER RECIRCULATING
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
HX HEAT EXCHANGER
IE INVERT ELEVATION
IF INLINE FAN
IN INCH OR INCHES
IP IRON PIPE
INV INVERT
IWH INSTANTANEOUS WATER HEATER
JAN JANITOR
JC JANITOR'S CLOSET
JS JANITOR'S SINK
LAT LEAVING AIR TEMPERATURE
LAV LAVATORY
LBS POUNDS
LHWR LOW TEMPERATURE HOT WATER
RETURN
LHWS LOW TEMPERATURE HOT WATER
SUPPLY
LIQ LIQUID (REFRIGERATION)
LV LOUVER
LP PROPANE GAS (LIQUID)
LWT LEAVING WATER TEMPERATURE
M METER
MAU MAKE-UP AIR HANDLING UNIT
MAX MAXIMUM
MB MOP BASIN
MBH BRITISH THERMAL UNITS (1000)
MBTUH BRITISH THERMAL UNITS (1000)
MC MECHANICAL CONTRACTOR
MCA MINIMUM CIRCUIT AMPACITY
MD MOTORIZED DAMPER
MECH MECHANICAL
MIN MINIMUM
MOCP MAXIMUM OVER CURRENT
PROTECTION
OA OUTDOOR AIR
OAI OUTDOOR AIR INTAKE
OC ON CENTER
OD OVERFLOW DRAIN
ODP OPEN DRIP PROOF
OXY OXYGEN
P PUMP
PC PLUMBING CONTRACTOR
PD PNEUMATIC OPERATED DAMPER
PIV POST INDICATING VALVE
PRV PRESSURE REDUCING VALVE
PT PRESSURE TEMPERATURE PLUG
PTAC PACKAGED TERMINAL AIR COND. UNIT
PVAC PROCESS VACUUM
S SINK
SA SUPPLY AIR
SAD SUPPLY AIR DIFFUSER
SAF SUPPLY AIR FAN
SAN SANITARY SEWER
SD SMOKE DETECTOR
SG SUPPLY AIR GRILLE
SH SHOWER HEAD
SHC STEAM HEATING COIL
SR SUPPLY REGISTER
SS STAINLESS STEEL
ST STORM
STM STEAM
SUCT SUCTION (REFRIGERATION)
TCC TEMPERATURE CONTROL CONTRACTOR
TCD TEMPERATURE CONTROL DAMPER
TCP TEMPERATURE CONTROL PANEL
TD TRANSFER DUCT
TG TRANSFER AIR GRILLE
TT THERMOSTATIC TRAP
TYP TYPICAL
UG UNDERGROUND
UH UNIT HEATER
UV UNIT VENTILATOR
V VENT
VAC VACUUM
VAV VARIABLE AIR VOLUME BOX
VD VOLUME DAMPER
VFD VARIABLE FREQUENCY DRIVE
VS VENT STACK (SANITARY)
VTR VENT THRU ROOF (SANITARY)
VUV VERTICAL UNIT VENTILATOR
W WASTE
WB WET BULB
WC WATER CLOSET
W/O WITHOUT
WH WATER HEATER
WSHP WATER SOURCE HEAT PUMP
NOTE:
NOT ALL ABBREVIATIONS AND/OR SYMBOLS ARE
USED IN THIS SET OF DOCUMENTS.
N2O NITROUS OXIDE
NC NORMALLY CLOSED
NIC NOT INCLUDED OR NOT IN CONTRACT
NIT NITROGEN
NO NORMALLY OPEN
KW KILOWATT
R REGISTER
RA RETURN AIR
RD ROOF DRAIN
RET RETURN
RF RETURN FAN
RG RETURN AIR GRILLE
RPZ REDUCED PRESSURE ZONE BACKFLOW PREVENTER
RR RETURN REGISTER
RTU ROOF TOP UNIT
MECHANICAL/PLUMBING AND FIRE PROTECTION GENERAL NOTES
1. THESE DRAWINGS ARE DIAGRAMMATIC IN CHARACTER AND DO NOT NECESSARILY INDICATE
EVERY OFFSET, VALVE, FITTING, ETC. REQUIRED. CONTRACTOR IS RESPONSIBLE FOR FIELD ROUTING
ALL DUCTWORK AND PIPING AT NO ADDITIONAL COST.
2. THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIALS AND OPERATIONS AND
PERFORM ALL LABOR REQUIRED FOR INSTALLATIONS AS INDICATED THE DRAWINGS, IN THE
SPECIFICATIONS AND AS REQUIRED BY LOCAL, STATE AND FEDERAL CODES, AND AS MAY BE
REASONABLY IMPLIED TO ACCOMPLISH COMPLETE MECHANICAL, PLUMBING AND FIRE PROTECTION
SYSTEMS.
3. ALL ELECTRICAL DISCONNECTS REQUIRED PER NEC CODE SHALL BE FURNISHED AND
INSTALLED BY THE ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE.
4. CONTRACTOR SHALL PROVIDE PRODUCTS AS SPECIFIED ON THE DRAWINGS AND
SPECIFICATIONS, HOWEVER, WHERE THE WORDS "EQUAL TO" ARE USED, ADDITIONAL PRODUCTS
MAY BE SUBMITTED AS PROPOSED SUBSTITUTIONS, BUT REQUIRE APPROVAL FROM
ARCHITECT/ENGINEER.
5. DESIGN DRAWINGS SHOW GENERAL ARRANGEMENT AND EXTENT OF WORK. THE DRAWINGS
ARE DIAGRAMMATIC AND MAY NOT NECESSARILY BE DRAWN TO SCALE FOR PURPOSE OF CLARITY AND LEGIBILITY. IT IS INTENDED THAT ALL ITEMS BE LOCATED SYMMETRICALLY WITH ARCHITECTURAL
ELEMENTS WHERE FEASIBLE AND BE INSTALLED TO AVOID OBSTRUCTIONS AND PRESERVE
HEADROOM. CONTRACTOR SHALL REVIEW PLANS OF OTHER TRADES WITH HIS OWN WORK TO AVOID CONFLICTS AND INTERFERENCES. CONTRACTOR MUST MAKE USE OF ALL SOURCES OF INFORMATION
INCLUDING DRAWINGS OF EQUIPMENT FURNISHED BY OTHERS. FAILURE TO REVIEW WORKING
SPACES OR CHECK DIMENSIONS IN QUESTION SHALL NOT WARRANT CONFLICTS.
6. DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE COMPLIMENTARY. WHERE DRAWINGS
AND SPECIFICATIONS CONFLICT EACH OTHER, IT IS THE CONTRACTORS RESPONSIBILITY TO GET CLARIFICATION FROM THE ARCHITECT/ENGINEER PRIOR TO BIDDING. FAILURE TO GET CLARIFICATION SHALL NOT RESULT IN ADDITIONAL COST AND THE MORE STRINGENT SHALL BE USED AS INTENDED
BASIS FOR BIDDING.
7. PLANS AND SPECIFICATIONS ARE INTENDED TO CONFORM TO GOVERNING CODES AND
STANDARDS. IF NON-CONFORMITIES ARE DISCOVERED WHILE BIDDING, OR PERFORMING THE WORK IMPLIED, BRING THE SAME TO THE ATTENTION OF THE ARCHITECT/ENGINEER FOR CLARIFICATION IN WRITING PRIOR TO SUBMITTING BID OR PROCEEDING WITH WORK. NON-CONFORMITIES OF CODE COMPLIANCE WORK INSTALLED AND CORRECTIONS REQUIRED WITHOUT CONSULTION AND WRITTEN RESPONSE OF SAME BY THE ENGINEER WILL BE THE CONTRACTORS FINANCIAL RESPONSIBILITY.
8. MOTORS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AS REQUIRED BY THE
EQUIPMENT FURNISHED BY THE MECHANICAL CONTRACTOR. MOTORS TO BE SUITABLE FOR LOAD, DUTY, VOLTAGE, FREQUENCY, HAZARD, SERVICE AND LOCATION INTENDED. SINGLE PHASE MOTORS MUST HAVE INTEGRAL THERMAL OVERLOAD PROTECTION IN ADDITION TO THAT PROVIDED IN MOTOR
CONTROLLERS. MOTORS TO CONFORM IN DESIGN AND PERFORMANCE TO THE MOTOR STANDARDS
OF NEMA. MOTORS RATED FOR CONTINUOUS DUTY UNDER FULL LOAD WITH A MAXIMUM
TEMPERATURE RISE OF 105 DEG F FOR OPEN, 125 DEG F FOR DRIP PROOF AND 130 DEG F FOR
EXPLOSION PROOF AND TOTALLY ENCLOSED TYPES. SUPPLY MOTORS WITH BELT DRIVES WITH
ADJUSTABLE BASES, REMOVABLE BELT GUARDS AND VARIABLE PITCH DRIVE PULLEY SELECTED SO THAT MIDPOINT OF VARIABLE RANGE OF PULLEY WILL DRIVE EQUIPMENT AT RATED SPEED. MOTORS
1 HP AND LARGER SHALL BE THREE PHASE (UNLESS OTHERWISE LISTED).
9. MOTOR CONTROLLERS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR FOR
MOTORS FURNISHED BY THE MECHANICAL CONTRACTOR. MOTOR CONTROLLERS SHALL BE OF SIZES AND TYPES AS NEEDED TO MEET THE OPERATIONAL CONDITIONS AS REQUIRED BY THE SEQUENCE OF OPERATION. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL THE POWER CIRCUIT, LOCAL
DISCONNECT AND CONNECTION TO MOTOR TERMINALS. MECHANICAL CONTRACTOR TO MOUNT
MOTOR CONTROLLERS AND CONTROL COMPONENTS AND WIRE AND MAKE ALL FINAL CONTROL
CONNECTIONS BETWEEN DEVICES.
10. THE DRAWINGS INDICATE KNOWN UTILITY AND DRAINAGE LINES IN ACCORDANCE WITH THE
INFORMATION FURNISHED TO THE ENGINEER. RESPONSIBILITY FOR LOCATING, UNCOVERING,
DISPOSING OR MAINTAINING ALL EXISTING UTILITY LINES TO REST SOLELY WITH THE CONTRACTOR.
VERIFY LOCATIONS AND DEPTHS OF SERVICE CONNECTION POINTS BEFORE PROCEEDING WITH
CONSTRUCTION.
11. CONTRACTOR SHALL CHECK EXISTING PREMISES BEFORE SUBMISSION OF BIDS TO CHECK
ALL CONDITIONS WHICH MAY EFFECT THE PERFORMANCE OF THE WORK INVOLVED. NO
ALLOWANCES OR EXTRA PAYMENT WILL BE MADE DUE TO CONTRACTOR'S FAILURE TO EXAMINE SITE
AND FULLY DISCERN WORKING CONDITIONS.
12. MECHANICAL CONTRACTOR SHALL RECEIVE, PROPERLY HOUSE, HANDLE, HOIST, AND
DELIVER TO PROPER LOCATION EQUIPMENT AND OTHER MATERIALS REQUIRED FOR THIS CONTRACT.
13. THE CONTRACTOR SHALL OBTAIN PERMITS, ARRANGE FOR INSPECTIONS, AND PAY FEES AND EXPENSES IN CONNECTION THEREWITH, AS A PART OF THE WORK REQUIRING SUCH PERMITS. EVERY
EFFORT IS MADE TO DESCRIBE THE WORK REQUIREMENTS IN CONFORMITY WITH APPLICABLE
CODES.
14. THE CONTRACTOR SHALL REVIEW ANY ALTERNATES OF OTHER TRADES, AND PRICE THEIR BID
TO ACCOUNT FOR ITEMS AFFECTING HIS WORK.
15. PIPING PASSING THROUGH CORRIDORS, TUNNELS, CHASES, ETC. SHALL BE CONSIDERED FOR
PROPER DRAINAGE. CONSULT WITH THE OTHER CONTRACTORS AND AVOID CONFLICT WITH
LOCATION OF PIPING. ORDER OF PRIORITY FOR ALL PIPING AND CONDUITS TO BE INSTALLED SHALL
BE AS FOLLOWS WITH THE HIGHEST PRIORITY LISTED FIRST.
A. PLUMBING DRAIN LINES
B. CONDENSATE LINES
C. DUCTWORK
D. FIRE PROTECTION
E. HOT AND COLD WATER PIPING
F. ELECTRICAL CONDUIT
16. WORK ASSIGNMENTS INFERRED BY THE DRAWINGS AND NOTES INCLUDED IN THESE PROJECT
DOCUMENTS ARE INFORMATIONAL ONLY AND ARE NOT INTENDED TO RELIEVE THE BIDDING
CONTRACTOR OF HIS OBLIGATION TO THE OWNER TO PROVIDE A COMPLETE AND COORDINATED
PROJECT. COMPREHENSIVE SUBCONTRACTOR COORDINATION AND FINAL WORK ASSIGNMENTS TO
SUBCONTRACTORS ARE THE SOLE RESPONSIBILITY OF THE BIDDING CONTRACTOR.
17. ALL DUCTS SERVING SUPPLY, RETURN AND EXHAUST TERMINALS SHALL BE PROVIDED WITH
BALANCE DAMPERS. FOR CLARITY, ALL DAMPERS MAY NOT BE SHOWN ON PLANS.
18. PROVIDE DIELECTRIC UNIONS/CONNECTIONS AT ALL JUNCTIONS OF DISSIMILAR METALS.
M
M
H
T
M
OD
OD
OD
OVERFLOW STORM - EXISTING
OVERFLOW STORM - DEMO
OVERFLOW STORM - NEW
P L
U R
I B
U
E
S U
N U M
C I
R C
U M
S P
I C
E
S I
Q U
E R E I S
P E N I N S U L A M
A M O E N A M
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
P R
E L
IM
IN
A
R Y
C O
N S
T R
U C
T
IO
N
F
IN
A L R
E C
O R
D
D A
T E
IS
S
U E
D F
O R
IN
D
E X
C O
D E
D M
V A
P R
O J E
C T
A
ID
E
N T
IF
IC
A T
IO
N
N O
S
H E
E T
D E
S
IG
N E
D
D R
A W
N
C H
E C
K E
D
A P
P R
O V
E D
S T
A T
E O
F M
IC
H
IG
A
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
A D
A M
L A
C H
R
A D
IR
E
C T
O R w w w .u p e a .c o m
U P
E A
P R
O
JE
C T
C A
L U
M E
T
M
IC
H
IG
A N
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
S A
F F
A
IR
S
S .P
S .P
G .A
.K
G .A
.K
D T
M B
F
IL
E
/2
.T
A P
/0
8/
/2
7/
M E
C H
A N
IC
A
L A
N D
P
LU
M B
IN
G
A B
B R
E V
IA
TI
O N
S A
N D
S Y
M B
O
LS
M
M
-0
C O
N S
T R
U C
T M
O T
O R
V E
H
IC
L E
S T
O R
A G
E B
U
IL
D
IN
G
C A
L U
M E
T
N
H I J K L M
C O
/N O
*NOTE: CO/NO2 SENSORS
SHALL HAVE A MINIMUM
OPERATING TEMPERATURE
RANGE OF -20°C TO 50°C.
FIRE AREA
"A"
127A
FIRE AREA
"B"
127B
C O
/N O
IL-2 IL-1
M M
EF-4EF-3
WALL CAP (TYP)
24x24 EA
OPEN ENDED 24x24 DUCT WITH BIRD SCREEN (TYP)
EF-2 EF-1
24x24 EA
MOUNT LOUVER @ 16'-0" AFF TO CENTERMOUNT LOUVER @ 16'-0" AFF TO CENTER
EL-2 EL-1
1 CO/NO2 SENSOR MOUNTED AT MANUFACTURER'S RECOMMENDATIONS. SENSOR SHALL BE VERIS AG04 USED IN CONJUNCTION WITH VERIS GWNP PLATFORM. PROVIDE POWER SUPPLY AS REQUIRED. PROVIDE RELAYS FOR EXHAUST FAN
AND LOUVER FOR INTERLOCK. SEE WIRING DIAGRAM ON ELECTRICAL DRAWINGS.
KEYNOTES
SEQUENCE OF OPERATIONS (CO/NO2 DETECTION SYSTEM)
EXHAUST FAN (EF-1 AND EF-2):
EXHAUST FAN SHALL BE SUPPLIED WITH LOCAL HAND/OFF/AUTO (HOA) SWITCH WITH RED INDICATOR LIGHT. INDICATOR LIGHT
SHALL BE ENERGIZED WHENEVER FAN IS IN OPERATION.
- IN "HAND" MODE, MOTORIZED DAMPER ON INTAKE LOUVER SHALL FULLY OPEN AND CONNECTED EXHAUST FAN SHALL BE
ENERGIZED AND SHALL REMAIN ENERGIZED UNTIL MANUALLY SHUT OFF.
- IN "AUTO" MODE, MOTORIZED DAMPER ON INTAKE LOUVER SHALL FULLY AND FAN SHALL OPERATE PER CO/NO2 SEQUENCE AS
INDICATED BELOW.
- IN "OFF" MODE, MOTORIZED DAMPER SHALL FULLY CLOSE AND EXHAUST FAN SHALL BE DE-ENERGIZED. THIS MODE SHALL BE
USED FOR MAINTENANCE AND INSPECTION PURPOSES ONLY.
CO/NO2 OPERATION:
UPON DETECTION OF USER ADJUSTABLE CO/NO2 LEVELS, MOTORIZED DAMPER ON INTAKE LOUVER SHALL FULLY OPEN AND CONNECTED EXHAUST FAN SHALL BE ENERGIZED. SYSTEM SHALL OPERATE FOR A MINIMUM OF 30 MINUTES AND UNTIL
CONCENTRATION LEVELS OF NO/CO2 HAVE DROPPED BELOW SET LEVELS.
NOTE
EXHAUST FANS EF-3 AND EF-4 SHALL RUN CONTINUOUSLY TO PROVIDE 0.05 CFM PER SQUARE FOOT OF EXHAUST. UPON CO/NO2 DETECTION, THE SEQUENCE LISTED BELOW SHALL PROVIDE AN ADDITIONAL 0.70 CFM PER SQUARE FOOT OF EXHAUST FOR A TOTAL
OF 0.75 CFM PER SQUARE FOOT PER 2021 MMC 404.1.
PARALLEL BLADE
DAMPER
LOW VOLTAGE DAMPER
ACTUATOR MOUNTED ON
EXTERIOR OF DUCT
(PROVIDE INSULATION
STANDOFF)
SEAL JOINTS WITH SILICONE
CAULK PERIMETER
VERIFY WALL CONSTRUCTION
O P
E N
IN
G
S
IZ
E
F
IE
L D
V E
R
IF
Y
DRAINABLE FIXED BLADE LOUVER
(SEE SCHEDULE)
PITCH DUCT TOWARDS
THE EXTERIOR
MESH INSECT SCREEN
SILICONE CAULK AT WALL PENETRATION
GRAVITY BACKDRAFT DAMPER
EXHAUST DUCTWORK
(SEE PLAN FOR SIZE) PAINTED ALUMINUM WALL CAP
(COLOR SELECTED BY OWNER)
IN-LINE EXHAUST FAN
(SEE MECHANICAL PLANS)
FLEXIBLE DUCT
CONNECTION (TYP)
EXHAUST DUCT TO
LOUVER
EXHAUST DUCT FROM
GARAGE
.0
CENTER DUCT ON FAN
WHERE POSSIBLE
SPRING VIBRATION
ISOLATORS
THREADED ROD FASTENED
SECURELY TO STRUCTURE
COORDINATE POWER WITH
ELECTRICAL CONTRACTOR
GRAVITY BACKDRAFT
DAMPER
SEAL JOINTS WITH SILICONE
CAULK PERIMETER
VERIFY WALL CONSTRUCTION
O P
E N
IN
G
S
IZ
E
F
IE
L D
V E
R
IF
Y
DRAINABLE FIXED BLADE LOUVER
(SEE SCHEDULE)LOUVER SUMP
P L
U R I B
U
E
S U
N U M
C I
R C
U M
S P
I C
E
S I
Q U
E R E I S
P E N I N S U L A M
A M O E N A M
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
P R
E L
IM
IN
A
R Y
C O
N S
T R
U C
T
IO
N
F
IN
A L R
E C
O R
D
D A
T E
IS
S
U E
D F
O R
IN
D
E X
C O
D E
D M
V A
P R
O J E
C T
A
ID
E
N T
IF
IC
A T
IO
N
N O
S
H E
E T
D E
S
IG
N E
D
D R
A W
N
C H
E C
K E
D
A P
P R
O V
E D
S T
A T
E O
F M
IC
H
IG
A
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
A D
A M
L A
C H
R
A D
IR
E
C T
O R w w w .u p e a .c o m
U P
E A
P R
O
JE
C T
C A
L U
M E
T
M
IC
H
IG
A N
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A N
D V
E T
E R
A N
S A
F F
A
IR
S
S .P
S .P
G .A
.K
G .A
.K
D T
M B
F
IL
E
/2
.T
A P
/0
8/
/2
7/
M E
C H
A N
IC
A
L P
LA
N
M
M
-0
C O
N S
T R
U C
T M
O T
O R
V E
H
IC
L E
S T
O R
A G
E B
U
IL
D
IN
G
C A
L U
M E
T
1/8" = 1'-0"1
MECHANICAL PLAN
FAN SCHEDULE
ID DESCRIPTION MANUFACTURER MODEL
NUMBER
AIR FLOW
(CFM)
EXTERNAL
S.P.
TOTAL S.P. RPM ELECTRICAL Notes
VOLTS PHASE HP - WATTS
EF-1 INLINE EXHAUST FAN GREENHECK SQ-16-VG 3170 0.1 in-wg 0.20 in-wg 1039 208 1 1 HP 1-4
EF-2 INLINE EXHAUST FAN GREENHECK SQ-16-VG 3220 0.1 in-wg 0.21 in-wg 1050 208 1 1 HP 1-4
EF-3 CEILING EXHAUST FAN GREENHECK SP-A200 230 - 0.20 in-wg 900 120 1 53 WATTS 1,5,6,7
EF-4 CEILING EXHAUST FAN GREENHECK SP-A200 230 - 0.20 in-wg 900 120 1 53 WATTS 1,5,6,7
1. COORDINATE ELECTRICAL REQUIREMENTS WITH ELECTRICAL CONTRACTOR.
2. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
3. PROVIDE WITH VIBRATION ISOLATION.
4. PROVIDE WITH CO/NO2 CONTROL SYSTEM.
5. PROVIDE WITH WALL CAP.
6. FAN TO RUN CONTINUOUSLY.
7. MOUNT NEAR CEILING.LOUVER SCHEDULE
ID DESCRIPTION MANUFACTURER MODEL MATERIAL
DIMENSIONS
(WxH) (IN)
THICKNESS
(IN)
CFM
PRESSURE
DROP
(IN. WG.)
FREE AREA
(SQ. FT.)
VELOCITY
(FT/MIN)
EL-1 DRAINABLE BLADE EXHAUST LOUVER GREENHECK ESD-435 ALUMINUM 36x36 4 3170 0.075 4.65 682
EL-2 DRAINABLE BLADE EXHAUST LOUVER GREENHECK ESD-435 ALUMINUM 36x36 4 3220 0.077 4.65 692
IL-1 DRAINABLE BLADE INTAKE LOUVER GREENHECK ESD-435 ALUMINUM 48x36 4 3170 0.04 6.33 501
IL-2 DRAINABLE BLADE INTAKE LOUVER GREENHECK ESD-435 ALUMINUM 48x36 4 3220 .042 6.33 509
INSTALL WITH HORIZONTAL CENTER LINE MATCHING ADJACENT WINDOW CENTERLINE.
PROVIDE WITH BIRDSCREEN AND MOTORIZED DAMPER PER DETAILS.
NOT TO SCALE2
DUCTED WALL LOUVER DETAIL (INTAKE)
VENTILATION CALCULATION AND CODE REQUIREMENTS PER MICHIGAN MECHANICAL CODE
ROOM
NUMBER ROOM NAME OCCUPANCY CLASSIFICATION
FLOOR AREA
(SQ FT) AIR DISTRIBUTION CONFIGURATION
PEOPLE OUTDOOR
AIR RATE,
CFM/PERSON
AREA
OUTDOOR AIR
RATE, CFM/FT2
EA RATE
CFM/FT2
PEOPLE
OUTDOOR AIR
RATE (CFM)
AREA
OUTDOOR AIR
RATE (CFM)
OUTDOOR
AIRFLOW TO
THE ZONE
(CFM)
ZONE
OUTDOOR
AIRFLOW
(CFM)
EXHAUST
AIRFLOW
RATE FROM
THE ROOM
(CFM)
128 FIRE AREA "A" Parking Garage (Enclosed) 4528 CEILING SUPPLY OF WARM AIR AND CEILING RETURN 0.0 0.00 0.75 0 0 0 0 3396
129 FIRE AREA "B" Parking Garage (Enclosed) 4588 CEILING SUPPLY OF WARM AIR AND CEILING RETURN 0.0 0.00 0.75 0 0 0 0 3441
Grand total 0 6837
NORTH
NOT TO SCALE4
WALL CAP DETAIL
NOT TO SCALE5
INLINE EXHAUST FAN DETAIL
NOT TO SCALE3
DUCTED WALL LOUVER DETAIL (EXHAUST)
| Sheets |
| M001 - MECHANICAL AND PLUMBING ABBREVIATIONS AND SYMBOLS |
| M101 - MECHANICAL PLAN |
File details come from the government source that posted it. Updated .