- ENGINEERING ANNEX ROOF - addendum 2
- Solicitation number
- 50013-BTB2858
- Issued by
- Orleans Parish, New Orleans City, Louisiana
About this file
This document is an Addendum (Addendum 02) issued by Holly & Smith Architects for the Engineering Annex Roof Replacement project at the University of New Orleans, associated with the State of Louisiana Facility Planning Control. The addendum, dated 4.24.2025, modifies original project specifications and drawings, specifically replacing three sheets: A001 (Demolition Plan), A901 (Roof Plan), and A912 (Roof Details). The project involves a comprehensive roof replacement for the Engineering Annex building, with detailed modifications to existing roof systems, including demolition of current roofing, installation of new roofing materials, and specific technical requirements for roof components.
The addendum provides comprehensive technical guidance for contractors, including specific instructions for roof system replacement, such as installing a cold-applied SBS modified bitumen roof system with tapered polyiso insulation, a 1/2" cover board, and associated flashings. The project includes multiple bid alternates (Base Bid: Main Roof, Add Alt. #1: High Roof, Add Alt. #2: Building Connector Roof), with precise specifications for roof deck elevations, insulation requirements, and integration with existing building structures. The document emphasizes detailed technical requirements, including provisions for lightning protection, mechanical penetrations, sealant applications, and specific metal flashing and coping details, indicating a highly technical and precise approach to the roof replacement project.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 50013-BTB2858-1.pdf | ||
| 50013-BTB2858.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HOLLY & SMITH ARCHITECTS, APAC 208 NORTH CATE ST. / HAMMOND, LA 70401
2302 MAGAZINE ST. / NEW ORLEANS, LA 70130
HOLLYANDSMITH.COM 100 E. VERMILION ST. , SUITE 406 / LAFAYETTE, LA 70501
ENGINEERING ANNEX
ROOF REPLACEMENT
UNIVERSITY OF NEW ORLEANS
Addendum 02
State of Louisiana Facility Planning Control
State Project No.: 01-107-24-05, F.01004598
UNO Purchasing Bid #: BTB 2858
UNO Project #: SP5286
H/S Project: 24054
Addendum: 02
Date: 4.24.2025
This Addendum forms a part of the Contract Documents and modifies the original specifications and drawings issued for bidding to the extent noted hereinafter. All other provisions of the Bid Documents shall remain unchanged.
Careful note of this Addendum will be taken by all parties of interest so that proper allowances are made in all computations, estimates and contracts and so that all trades affected are fully advised in the performance of the work that will be required of them. Acknowledge receipt of this Addendum on the Bid Form.
Modifications to the Drawings
Sheet A001
1.02 Delete Sheet A001 – DEMOLITION PLAN in its entirety. In lieu thereof, substitute revised Sheet A001 –
DEMOLITION PLAN, included herein as part of this Addendum.
Sheet A901
1.03 Delete Sheet A901 – ROOF PLAN in its entirety. In lieu thereof, substitute revised Sheet A901 – ROOF
PLAN, included herein as part of this Addendum.
Sheet A901
1.04 Delete Sheet A912 – ROOF DETAILS in its entirety. In lieu thereof, substitute revised Sheet A912 – ROOF
DETAILS, included herein as part of this Addendum.
END OF ADDENDUM.
1. EXISTING ROOF: BUILT UP ROOF WITH BROADCAST AGGREGATE
ON TAPERED PERLITE WITH APPROXIMATELY 3" THICK AT EDGE
OF ROOF DRAINS AND 9-1/2" THICK AT ROOF PERIMETER. PERLITE
APPEARS TO BE SET IN PITCH DIRECTLY ON CAST IN PLACE
CONCRETE DECK.
2. CLEAN EXISTING CONCRETE DECK SUFFICIENTLY TO PROVIDE A
SURFACE SUITABLE FOR ADHESIVE ATTACHMENT OF THE NEW
RIGID INSULATION. PROVIDE ONE SQUARE SAMPLE AREA FOR
CONFIRMATION WITH ROOFING MEMBRANE MANUFACTURER.
3. DIMENSIONS, ROOF THICKNESSES, LOCATIONS, SIZES AND
ORIENTATIONS OF ALL ROOF AREAS AND ROOF MOUNTED ITEMS
ARE ALL APPROXIMATE. FIELD VERIFY ALL CONDITIONS
THROUGHOUT.
4. UNLESS NOTED OTHERWISE, DASHED LINES INDICATE WORK TO
BE DEMOLISHED AND REMOVED.
5. DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW EVERY ITEM
TO BE DEMOLISHED; WHETHER LISTED OR NOT, REMOVE ALL
COMPONENTS NEEDED FOR NEW WORK.
6. PROTECT ALL WORK THAT IS SCHEDULED TO REMAIN FROM
DAMAGE.
7. PRIOR TO EXECUTING WORK, NOTIFY THE ARCHITECT IF
CONDITIONS DEVIATE FROM WHAT IS SHOWN.
8. DEMOLISH ALL LIGHTNING PROTECTION SYSTEM COMPONENTS
THROUGHOUT WITH THE EXCEPTION OF ALUMINUM THREADED
GROUND RODS ATTACHED TO ROOF DECK.
9. SALVAGE ALL STAINLESS STEEL FLASHING AND COPING FOR
DELIVERY TO METAL RECYCLING COMPANY. OWNER WILL
COLLECT VALUE OF RECYCLED MATERIAL.
10. CONFIRM IF CONDUIT OR PIPE PENETRATIONS ARE STILL IN
SERVICE. WHERE NO LONGER IN USE AND/OR CAPPED ABOVE
ROOF, REMOVE LINE TO BELOW ROOF DECK AND CAP. WHERE
STILL IN USE, REMOVE ALL PITCH POCKETS, MASTIC, LEAD
FLASHING AND PREPARE FOR LIQUID FLASHING.
11. CUT BACK TREE BRANCHES FROM EXTERIOR FACE OF ROOF
PARAPET 24" CLEAR MIN. THERE SHALL BE NO TREE BRANCHES
ABOVE THE ROOF OR PARAPET.
GENERAL NOTES
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
013401340134
/A
1/ A
3/ A
4/A011
6/A011
/A
8/A011
/A
12/A
13/A011
14/A011
/A
19/A011
/A
3/ A01
2/A012
1/A012
0137 0137
0137 0137
EXISTING
ROOF TO
REMAIN -
N.I.C.
EXISTING
ROOF TO
REMAIN -
N.I.C.
EXISTING TOWER ROOF
TO REMAIN - N.I.C.
32'-3"
'-0
/2
'-1
/2
'-4
/2
48'-6 1/2" 59'-5 1/2" 23'-11"
'-6
'-1
'-0
'-4
/2
42'-11" 185'-5" 59'-9"
94'-7" 43'-5"
(OPEN TO
COURTYARD
BELOW)
/A
5/ A
/A
8/ A
/A
/A
10/A012
11/A012
12/A
16/A012
4/A012 16 /A
9/A011
/A
TYP
TYP
29'-7"
WEATHERPROOF DAILY: CONTRACTOR SHALL SEAL THE ROOF ON
THE SAME DAY AS ANY DEMO/INSTALLATION. IN ADDITION, THE
CONTRACTOR SHOULD NOT REMOVE MORE ROOF THAN CAN BE
REPLACED IN THE SAME DAY, KEEPING WATCH ON HOURLY LOCAL
RAIN FORECASTS.
ADD ALT. # 1:
HIGH ROOF
ADD ALT. # 2:
BUILDING
CONNECTOR
ROOF
PLUMBING VENT STACK
DEMOLITION LEGEND
ROOF DRAIN
REMOVE EXISTING ROOF SYSTEM
AND ALL FLASHING DOWN TO TOP
OF EXISTING ROOF DECK
4 / A011
REFERENCE FOR PHOTOGRAPH OF
EXISTING CONDITION
EXHAUST FAN ASSEMBLY
ON CURB
DUCT PENETRATION AND AIR
HANDLING ASSEMBLY ON CURBS
/8 A013
/1 A013
/5 A013
/9 A013
/3 A013
/7 A013
/10 A013
/6 A013
/4 A013
BASE BID: MAIN ROOF
TOP OF CONC. DECK =
15'-0" +/- V.I.F.
ADD ALT. # 1: HIGH ROOF
TOP OF CONC. DECK =
22'-0" +/- V.I.F.
ADD ALT. # 2:
BUILDING
CONNECTOR ROOF
TOP OF CONC.
DECK = 10'-8" +/-
V.I.F.
N.I.C.
N.I.C.
KEY PLAN
PROJECT NO.
DATE
This drawing, as an instrument of service, is and shall remain the property of the Architect and shall not be reproduced, published, or used in any way without the permission of the Architect.
© Holly & Smith Architects, APAC
PROJECT MANAGER
PHASE
QUALITY CONTROL
DESCRIPTION DATENO.
1"
0" 1"½"
½"
The graphic scale at the bottom left corner of this drawing must measure 1"x1" otherwise all listed scales are null and void.
HOLLY & SMITH
ARCHITECTS
HAMMOND
T 9 8 5 . 3 4 5 . 5 2 1 0 www.hollyandsmith.com
NEW ORLEANS
T 5 0 4 . 5 8 5 . 1 3 1 5
LAFAYETTE
T 3 3 7 . 2 7 9 . 2 0 1 0
S T
A T
E P
R O
JE
C
T N
O -1
-2
-0
F
.0
S T
A T
E I
D S
IT
E C
O D
E -3
-0
U .N
.O P
R O
JE
C
T
S
P
U .N
.O P
U R
C H
A S
IN
G B
ID
B
T B
C R e v it M o d e ls
\2
U
N O
E n g in e e ri n g A n n e x R o o f R e p la c e m e n t_ ra y h o lly a n d s m it h .c o m
.r v t
/2
/2
:5
:3
A
M
A001
DEMOLITION PLAN
24054
02/07/25
RK
CD
AV
BID
DOCUMENTS
L A
K E
S H
O R
E D
R
IV
E , N
E W
O R
L E
A N
S , L
A
U N
IV
E
R S
IT
Y O
F N
E W
O R
L E
A N
S
E N
G
IN
E E
R
IN
G A
N N
E X
R O
O F
R E
P L
A C
E M
E N
T
KEYNOTE LEGEND
0130 DEMOLITION ROOF HATCH ASSEMBLY AND WOOD BLOCKING DOWN
TO TOP OF CONCRETE ROOF DECK. SEE DETAIL -
0131 DEMOLISH ALL OF ROOF SYSTEM DOWN TO TOP OF CONCRETE
ROOF DECK WITHIN THE HATCHED AREA ENCLOSED BY BOLD
DASHED LINE. THIS INCLUDES ALL STAINLESS STEEL COUNTER
FLASHING AT CAST STONE PANEL REGLETS, FLASHING, SEALANT,
AGGREGATE, MEMBRANES, INSULATION, CANTS AND PITCH
POCKETS.
0132 DEMOLISH ALL STAINLESS STEEL COPING, FASTENERS, CLEATS
AND WOOD BLOCKING AT TOP OF PARAPET TYPICAL. SEE DETAIL -
0133 DEMOLISH MEMBRANE FLASHING AND CANT STRIP AT BASE OF
EXHAUST FAN CURB. EXISTING CURB AND COUNTERFLASHING TO
REMAIN. SEE DETAIL -
0134 DEMOLISH ROOF DRAIN DOME, COLLAR, BOLTS AND ANY ROOF
MEMBRANE OR MASTIC ATTACHED TO THE DRAIN BASIN. EXISTING
DRAIN BASIN TO REMAIN. SEE DETAIL -
0135 REMOVE BASE FLASHING ON GALVANIZED STEEL SUPPORT POSTS
AT CONDUITS RUNS. CONDUIT AND SUPPORT POSTS ARE EXISTING
TO REMAIN AND SHALL REMAIN IN OPERATION THROUGHOUT
RENOVATION.
0136 EXISTING GALVANIZED STEEL LADDER TO REMAIN.
0137 DEMOLISH STAINLESS STEEL THROUGH WALL SCUPPER
ENCLOSURE, WOOD BLOCKING, CAN STRIP, MEMBRANE FLASHING
AND MASTIC. EXISTING CAST STONE PANEL ROUGH OPENING TO
REMAIN. SEE DETAIL -
0138 DEMOLISH ALL SEALANT AND BACKER ROD FROM VERTICAL JOINTS
IN EXTERIOR FACE OF CAST STONE PANELS ALONG THIS WALL,
FROM TOP OF CONCRETE DECK TO TOP OF PARAPET ABOVE.
PREPARE JOINT FOR NEW SEALANT INSTALLATION.
0139 DEMOLISH ALL SEALANT AND BACKER ROD FROM VERTICAL JOINTS
IN EXTERIOR FACE OF CAST STONE PANELS ALONG THIS WALL,
FROM TOP OF CONCRETE DECK TO HORIZONTAL JOINT
APPROXIMATELY 12'-0" ABOVE TOP OF ROOF DECK. PREPARE JOINT
FOR NEW SEALANT INSTALLATION.
0147 DEMOLISH METAL JACK VENT ASSEMBLY AND WOOD BLOCKING
DOWN TO TOP OF CONCRETE ROOF DECK.
3/32" = 1'-0"1 ROOF PLAN - DEMOLITION
N
TRUE
NORTH
KEYNOTE LEGEND
0148 DEMOLISH METAL GOOSE NECK VENT ASSEMBLY, METAL FLASHING,
WOOD BLOCKING AND/OR CURB DOWN TO TOP OF CONCRETE ROOF
DECK. SEE DETAIL -
0149 DEMOLISH ALL LEAD FLASHING, MEMBRANE, MASTIC AND SEALANT
ON VENT PIPE DOWN TO TOP OF CONCRETE ROOF DECK. SEE
DETAIL -
0150 DISCONNECT EXHAUST FAN ASSEMBLY, REMOVE FROM SUPPORT
CURB AND SET ASIDE FOR RE-INSTALLATION ON NEW CURB.
DEMOLISH EXISTING SUPPORT CURB ASSEMBLY AND BLOCKING
DOWN TO TOP OF CONCRETE ROOF DECK. SEE DETAIL -
0161 PULL BACK LIGHTNING PROTECTION ATTACHED TO THIS PARAPET
AND ACCESS LADDER AND SECURE TO N.I.C. ROOF UNTIL
RENOVATION WORK IS COMPLETE AND REINSTALL.
0162 DISCONNECT POWER TO PARAPET MOUNTED LIGHT FIXTURE, PULL
BACK WIRING TO AN INTERIOR LOCATION AND DEMOLISH (2) 1"
DIAMETER GALV. METAL CONDUITS, FITTINGS, JUCTION BOXES AND
SUPPORT CURBS WITHIN THE DEMOLISHED ROOF AREA. LIGHT
FIXTURE IS EXISTING TO REMAIN.
0166 DEMOLISH ALL METAL FLASHING, MEMBRANE, CANTS, MASTIC AND
BLOCKING AT CONCRETE SUPPORT BASE. TEMPORARILY
DISCONNECT AND REMOVE AIR HANDLER ASSEMBLY, SHOCK
ABSORBER BASE, AND STEEL BEAM DUNNAGE FROM TOP OF
CONCRETE SUPPORT BASE. SEE DETAIL -
0167 DEMOLISH MEMBRANE FLASHING AND CANT STRIPS. PREP FACE OF
CURB AND DUCT TRANSITION FOR NEW LIQUID FLASHING SYSTEM
AT BASE.
0168 DEMOLISH EXHAUST FAN ASSEMBLY, ELECTRICAL SERVICE,
SUPPORT CURB AND FLASHING DOWN TO TOP OF CONCRETE ROOF
DECK. TERMINATE ELECTRICAL BELOW ROOF DECK AND CAP.
0190 EXISTING TO REMAIN - N.I.C.
2 ADDENDUM 02 04/24/25
32'-3"
'-0
/2
'-1
/2
'-4
/2
(OPEN TO
COURTYARD
BELOW)
48'-6 1/2" 59'-5 1/2" 23'-11"
'-6
'-1
'-0
9.30"
8.28"
8.17"
10.78"
10.36"
'-4
/2
42'-11" 185'-5" 59'-9"
7.27"
7.27"
7.53" 8.16"
MAIN ROOF
10.36"
R I
D G
E
R I
D G
E
R I
D G
E
R I D G E
R I D G E
R I D G E
TYP
TYP
TYP
TYP
TYP
TYP
0762 0762
0762 0762
TYP
0722 0722 0722
0721 0721
0722 0722
TYP
TYP
TYP
TYP
TYP
TYP
0761 0762
94'-7" 43'-5"
3.75"
3.75" 3.75"
3.75" 3.75"
3.75"
3.75"
8.63"
3.75"
8.22"
3.75"
8.11"
3.75"
3.75"
9.40"
8.30"
6.84"
6.25"
3.75"
3.75"
7.25"
6.25"
7.50"
6.44"
3.75"
7.58"
3.75"
3.75"
9.00"
8.39"
8.31"
EXISTING
ROOF TO
REMAIN -
N.I.C.
EXISTING
ROOF TO
REMAIN -
N.I.C.
EXISTING ROOF TO
REMAIN - N.I.C.
(OPEN TO
COURTYARD
BELOW)
TYP
TYP
0730 0730
0782 0782
0782 0782
R I
D G
E
7.69"
29'-7"
A912
A912
Sim
A912
29'-7"
A912
ADD ALT. # 1:
HIGH ROOF
ADD ALT. # 2:
BUILDING
CONNECTOR
ROOF
GENERAL NOTES
1. TYPICAL ROOF SYSTEM: COLD APPLIED SBS MODIFIED BITUMEN ROOF SYSTEM ON 1/2" COVER
BOARD AND AN R-25 AVERAGE TAPERED POLYISO INSULATION VALUE ON EXISTING CAST
CONCRETE ROOF DECK. ENTIRE SYSTEM IS SET IN ADHESIVE ON EXISTING ROOF DECK IN
PATTERN ENGINEERED BY ROOF MEMBRANE MANUFACTURER TO RESIST UPLIFT. PROVIDE 3/16"
PER FOOT SLOPE TYPICAL UNLESS NOTED OTHERWISE. REFER TO DETAILS AND SPECIFICATIONS
FOR MORE INFORMATION.
2. LIGHTNING PROTECTION SYSTEM: PROVIDE LIGHTNING PROTECTION SYSTEM THROUGHOUT
AREAS WHERE ROOF IS REPLACED UNLESS NOTED OTHERWISE. RE-USE EXISTING ALUMINUM
THREADED GROUND RODS ATTACHED TO ROOF DECK WHERE POSSIBLE. SEE DETAIL -
3. METAL FLASHING: ALL METAL FLASHING, COUNTER FLASHING, EDGE METAL AND COPING NOTED IN THE DRAWINGS SHALL BE 24 G.A. STAINLESS STEEL TO MATCH THE EXISTING 9 STORY ROOF.
4. SEE SHEET A911 FOR ROOFING DETAILS. WHERE DETAILS ARE NOT SHOWN, PROVIDE STANDARD
DETAILS AS RECOMMENDED BY THE ROOFING MANUFACTURER AND NRCA. REPORT ANY
DISCREPANCIES BETWEEN DETAILS, MANUFACTURER’S RECOMMENDATIONS, AND FIELD
CONDITIONS TO THE ARCHITECT.
5. THE WORK SHALL INCLUDE THE INSTALLATION OF 18 SQUARES OF MODIFIED BITUMEN CAP SHEET PLIES ONLY AS DETERMINED BY ARCHITECT TO ELIMINATE PONDING OBSERVED DURING PONDING WATER INSPECTION. FOR ANY QUANTITY REQUIRED BEYOND THIS AMOUNT, REFER TO UNIT PRICE
SPECIFICATION.
6. WHERE DETAILS ARE NOT SHOWN, PROVIDE STANDARD DETAILS AS RECOMMENDED BY THE
ROOFING MANUFACTURER AND NRCA. REPORT ANY DISCREPANCIES BETWEEN DETAILS,
MANUFACTURER’S RECOMMENDATIONS, AND FIELD CONDITIONS TO THE ARCHITECT. COMPLY
WITH MANUFACTURER'S RECOMMENDATIONS FOR ROOF PENETRATIONS, FLASHINGS, ETC.
7. DIMENSIONS, ROOF THICKNESSES, LOCATIONS, SIZES AND ORIENTATIONS OF ALL ROOF AREAS
AND ROOF MOUNTED ITEMS ARE ALL APPROXIMATE. FIELD VERIFY ALL CONDITIONS
THROUGHOUT.
8. ALL ELECTRICAL, MECHANICAL AND/OR PLUMBING WORK REQUIRED TO BE DISCONNECTED,
RECONFIGURED, EXTENDED, RELOCATED AND/OR TO HAVE EXISTING LINES REPOSITIONED SHALL
MEET ALL APPLICABLE CODE REQUIREMENTS AND REGULATIONS.
9. PROVIDE REINFORCED LIQUID FLASHING AT ALL PIPE AND CONDUIT PENETRATIONS THROUGH ROOF ASSEMBLY, WHETHER SHOWN ON PLAN OR NOT, UNLESS DETERMINED TO NO LONGER BE IN
SERVICE. IF NO LONGER IN SERVICE CAP LINE BELOW ROOF DECK.
10. PATCH CHIPPED OR SPALLED PORTIONS OF CAST STONE WALL PANELS AT SEALANT JOINTS
AND/OR FLASHING CONDITIONS WITH CEMENTITIOUS MORTAR.
11. AVOID INSTALLING FASTENERS IN CONCRETE SUBSTRATE WITHIN 2" OF CONCRETE EDGE OR
CORNER. FOLLOW ACI GUIDELINES TYPICAL.
ROOF LEGEND
EXISTING PLUMBING VENT STACK
TO REMAIN IN PLACE WITH NEW
BASE FLASHING
EXISTING ROOF DRAIN
LOCATION - SEE KEYNOTE FOR
RENOVATION EXTENT
TYP. ROOF SYSTEM: SEE GENERAL
NOTES
T Y
P
'-0
3"
TOTAL THICKNESS OF INSULATION
AND COVER BOARD ABOVE
CONCRETE ROOF DECK
CRICKETS AND ROOF DRAIN SUMP:
SBS MODIFIED BITUMEN ROOF
MEMBRANE OVER TAPERED ROOF
INSULATION AT CRICKETS AND ROOF
DRAIN SUMP (1/2":1'-0" MIN. SLOPE)
EXISTING EXHAUST FAN
ASSEMBLY ON CURB
EXISTING AIR HANDLING
ASSEMBLY AND DUCT
PENETRATION ON CURB/
DUNNAGE
NEW GOOSE NECK VENT
ASSEMBLY ON CURB
/4 A912
/1 A911
/6 A911
/10 A912
/5 A911
/2 A911
/4 A911
/8 A911
/10 A911
/3 A911
/11 A911
/6 A912
/7 A911 /1 A911
ROOF DRAIN SUMP - 1/2" : 1'-0"
SLOPE
/3 A912
/3 A912
/2 A911
/11 A912
BASE BID: MAIN ROOF
TOP OF CONC. DECK =
15'-0" +/- V.I.F.
ADD ALT. # 1: HIGH ROOF
TOP OF CONC. DECK =
22'-0" +/- V.I.F.
ADD ALT. # 2:
BUILDING
CONNECTOR ROOF
TOP OF CONC.
DECK = 10'-8" +/-
V.I.F.
N.I.C.
N.I.C.
KEY PLAN
PROJECT NO.
DATE
This drawing, as an instrument of service, is and shall remain the property of the Architect and shall not be reproduced, published, or used in any way without the permission of the Architect.
© Holly & Smith Architects, APAC
PROJECT MANAGER
PHASE
QUALITY CONTROL
DESCRIPTION DATENO.
1"
0" 1"½"
½"
The graphic scale at the bottom left corner of this drawing must measure 1"x1" otherwise all listed scales are null and void.
HOLLY & SMITH
ARCHITECTS
HAMMOND
T 9 8 5 . 3 4 5 . 5 2 1 0 www.hollyandsmith.com
NEW ORLEANS
T 5 0 4 . 5 8 5 . 1 3 1 5
LAFAYETTE
T 3 3 7 . 2 7 9 . 2 0 1 0
S T
A T
E P
R O
JE
C
T N
O -1
-2
-0
F
.0
A T
E I
D S
E C
O D
E -3
-0
U .N
.O P
R O
JE
C
T
S
P
.O P
U R
C H
A S
IN
G B
ID
B
T B
R e v it M o d e ls
\2
U
N O
E n g in e e ri n g A n n e x R o o f R e p la c e m e n t_ ra y h o lly a n d s m it h .c o m
.r v t
/2
/2
:5
:3
A
M
A901
ROOF PLAN
24054
02/07/25
RK
CD
AV
BID
DOCUMENTS
L A
K E
S H
O R
E D
R
IV
E , N
E W
O R
L E
A N
S , L
A
U N
IV
E
R S
IT
Y O
F N
E W
O R
L E
A N
S
E N
G
IN
E E
R
IN
G A
N N
E X
R O
O F
R E
P L
A C
E M
E N
T
N
TRUE
NORTH
3/32" = 1'-0"1 ROOF PLAN
KEYNOTE LEGEND
0560 PREP, PRIME AND PAINT EXISTING STEEL ACCESS
LADDER WITH GALVANIZING PAINT. THIS WORK
SHALL BE PART OF THE BASE BID. SEE DETAIL -
0710 FLASH NEW ROOF SYSTEM INTO EXISTING EXHAUST
FAN SUPPORT CURB. SEE DETAIL -
0713 FLASH NEW ROOF SYSTEM INTO EXISTING CURB
ENCLOSED DUCT PENETRATION. SEE DETAIL -
0721 PROVIDE TAPERED INSULATION CRICKET AS SHOWN
WITH 1/2" PER 1'-0" SLOPE TO GUIDE STORM WATER
TOWARDS DRAINS.
0722 INSTALL NEW CAST IRON DOME, COLLAR AND
EXTENSION AT EXISTING DRAIN BASIN. COORDINATE
INSTALLATION WITH TAPERED INSULATION SUMP.
SEE DETAIL -
0725 INSULATED ROOF HATCH ASSEMBLY ON TREATED
BLOCKING. SEE DETAIL -
0730 FLASH ROOF SYSTEM INTO EXISTING VENT STACK.
SEE DETAIL -
0740 24 GA S.S. GOOSE NECK VENT ON INSULATED CURB
MATCHING SIZE, FUNCTION AND CONFIGURATION OF
DEMOLISHED ASSEMBLY. COORDINATE
INSTALLATION WITH CONNECTION TO EXISTING
DUCT. SEE DETAIL -
0741 ALUMINUM EXHAUST VENT MATCHING SIZE,
FUNCTION AND CONFIGURATION OF DEMOLISHED
ASSEMBLY. SEE DETAIL -
0742 RECONNECT AND MOUNT EXISTING AIR HANDLING
UNIT WITH SHOCK ABSORBERS AND STEEL
DUNNAGE TO CONCRETE BASE IN SAME
CONFIGURATION AS ORIGINAL INSTALLATION. PREP,
PRIME AND PAINT STEEL DUNNAGE WITH
GALVANIZING PAINT. REPLACE EXISTING NUTS AT
ANCHOR BOLTS AS NEEDED.
0761 24 GA S.S. METAL COPING W/ DRIP EDGE. SEE
DETAIL -
0762 FLASH 24 GA S.S. METAL THROUGH WALL SCUPPER
INTO EXISTING OPENING IN CAST STONE PARAPET.
SEE DETAIL -
KEYNOTE LEGEND
0775 INSTALL SILICONE SEALANT AND BACKER ROD IN
EXISTING VERTICAL AND HORIZONTAL JOINTS IN
CAST STONE PANELS FROM ROOF DECK UP TO TOP
OF PARAPET ABOVE AT EXTERIOR SIDE OF FACADE.
SEE TYPICAL DETAIL -
0776 INSTALL SILICONE SEALANT AND BACKER ROD IN
EXISTING JOINTS IN CAST STONE PANELS FROM
ROOF DECK UP TO NEAREST HORIZONTAL JOINT AT
APPROXIMATELY 12'-0" ABOVE ROOF. WHERE CAST
STONE PANELS SLOPE INTO INSET WINDOWS,
CONTINUE SEALANT ASSEMBLY ON SLOPED JOINTS
UP TO BOTTOM OF SILL FLASHING AT BASE OF
WINDOW. SEE TYPICAL DETAIL -
0780 FLASH BASE OF EXISTING GALVANIZED STEEL PIPE
SUPPORTS AT EXISTING ELECTRICAL CONDUITS.
MAINTAIN OPERATION OF CONDUITS THROUGHOUT
RENOVATION. SEE DETAIL -
0781 INSTALL NEW INSULATED CURB AT PERIMETER OF
EXISTING CONCRETE BASE AND COVER WITH LIQUID
FLASHING AND 24 GA S.S. METAL CAP FLASHING. SEE
DETAIL -
0782 PROVIDE 24 GA S.S. METAL SADDLE FLASHING FOR
COPING WHERE PARAPET TERMINATES INTO
PERPENDICULAR WALL. SEE DETAIL -
0783 REPLACE DEMOLISHED CONDUITS WITH (2) 1"
DIAMETER GALV. METAL CONDUITS ON RUBBER
CURBS AT 48" O.C. AND RE-FEED EXISTING PARAPET
MOUNTED LIGHT FIXTURE. PROVIDE NEW GALV.
METAL JUNCTION BOXES, FITTINGS AND MEET N.E.C.
REQUIREMENTS FOR ALL MATERIALS AND
INSTALLATION.
0785 FLASH NEW ROOF SYSTEM INTO NEW INSULATED
SUPPORT CURB AND REINSTALL EXISTING EXHAUST
FAN ON TOP. SEE DETAIL -
0786 INFILL EXISTING EXHAUST FAN OPENING WITH
GALVANIZED METAL DECK AND PERIMETER
SUPPORT ANGLES. SEE DETAIL -
1 ADDENDUM 01 04/22/25
2 ADDENDUM 02 04/24/25
GALV. STL. FRAME
& CAP FLSHG.
EXISTING CONCRETE
ROOF DECK TO REMAIN
TAPERED RIGID
INSULATION
1/2" THICK COVER
BOARD WITH
STAGGERED JOINTS
CANT STRIP
EXISTING STEEL
SHIP'S LADDER TO
REMAIN
1" FIBERBOARD INSULATED
ROOF HATCH ASSEMBLY
ON TREATED WOOD
BLOCKING. SECURE TO
BLOCKING WITH NO. 10 -
2.5" GALV. CONSTRUCTION
SCREWS AT 8" O.C.
TREATED 2X6 WOOD
BLOCKING
1/2" DIAMETER HOT
DIPPED GALV.
EXPANSION ANCHOR AT
24" O.C. MAX.
TORCH APPLIED BASE
FLASHING
BASE PLY
V .I .F
'-0
M
IN
TERMINATION BAR
ASSEMBLY, CONTINUOUS
SEALANT
'-0
(U
P P
E R
R O
O F
T O
M A
IN
R
O O
F
'-4
V
.I .F
'-8
V
.I .F
'-0
M A
IN
R
O O
F T
O L
O W
E R
R O
O F
PREP, PRIME AND
PAINT EXISTING
STEEL ACCESS
LADDER WITH
GALVANIZING
PAINT. THIS WORK
SHALL BE PART OF
THE BASE BID. SEE
DETAIL -
A911
Sim
A911
Sim
SEAL ALL WALL
FASTENERS
THOROUGHLY
SEAL ALL WALL
FASTENERS
THOROUGHLY
FLASHING CAP SHEET ON
FLASHING BASE PLY ON CAST
STONE SURFACE.
EXPOSED FACE OF
CAST STONE PANEL
TYP. RECEIVER
FLASHING AND
REMOVABLE
COUNTER FLASHING
DETAIL
POLY-
URETHANE
SEALANT
AT REGLET
24 GA S.S.
COPING
ASSEMBLY
CANT STRIP
POLYURETHANE
SEALANT AT REGLET
AT TOP OF RECEIVER
ON SADDLE FLASHING
6"
6"
PARAPET
WIDTH
24 GA S.S. SADDLE
FLASHING. EXTEND
DRIP EDGE DOWN OVER
RECEIVER FLASHING AT
REGLET
4"
5"
EXPOSED FACE OF
CAST STONE PANEL
HIGH TEMP SELF
ADHERED FLASHING
MEMBRANE OVER
LIQUID FLASHING
6"
6"
PARAPET
WIDTH
REINFORCED
LIQUID FLASHING
SYSTEM ON STONE
PANEL AND OVER
CAP SHEET AT
PARPET. EXTEND
DOWN OVER
SELANT JOINT
4"
5"
/9 A911
POLY-
URETHANE
SEALANT
AT REGLET
EXISTING CAST STONE
PARAPET
FLASHING CAP SHEET ON
FLASHING BASE PLY ON CAST
STONE SURFACE.
TYP. RECEIVER
FLASHING AND
REMOVABLE
COUNTER FLASHING
DETAIL
CANT STRIP
EXISTING CAST
STONE PARAPET
/9 A911
'-8
V
.I .F
'-0
V
.I .F
6" 3/4" 1'-6"
'-0
/2
V
.I .F
S E
E P
L A
N
V A
R
IE
S
V .I .F
A912
Sim
1/2" THICK COVER BOARD
WITH STAGGERED JOINTS
TAPERED RIGID
INSULATION
CANT STRIP
TORCH APPLIED
BASE FLASHING
EXISTING CONCRETE ROOF
DECK TO REMAIN
24 GA S.S. CAP FLASHING WITH
DRIP EDGE AT PERIMETER.
EXISTING CAST CONCRETE
STRUCTURE
24 GA S.S. METAL COPING
ASSEMBLY
EXISTING CAST
STONE PANEL TO
REMAIN
6" 3/4" 1'-6"
V .I .F
24 GA S.S. CAP
FLASHING WITH DRIP
EDGE AT PERIMETER.
24 GA S.S. METAL COPING
ASSEMBLY
EXISTING CAST STONE
PANEL TO REMAIN
1/2" DIAMETER HOT DIPPED
GALV. EXPANSION ANCHOR
AT 24" O.C. MAX.
2X WOOD BLOCKING RIPPED TO
DIMENSIONS AND SHAPE SHOWN
CONTINUOUS 18 GA S.S.
CLEAT NAILED TO
BLOCKING AT 8" O.C.
ELASTOMERIC
SEALANT JOINT
FLASHING BASE PLY
HIGH DOMED GASKETED
FASTENER AT 16" O.C. MAX
LIQUID FLASHING SYSTEM
WITH FLEECE REINFORCING
FLASHING CAP SHEET
HIGH DOMED GASKETED
FASTENER AT 16" O.C. MAX
EXISTING CAST CONCRETE
STRUCTURE
5" +/- V.I.F.
24 GA S.S. RECEIVER
FLASHING SET IN EXISTING
REGLET WITH SPRING LOCK
LEG, SECURED WITH LEAD
WEDGES ATA 12" O.C.
COVERED WITH BACKER
ROD AND SEALANT.
24 GA S.S. METAL
COUNTER FLASHING
WITH DRIP EDGE
1/2" THICK COVER
BOARD WITH
STAGGERED JOINTS
PROVIDE LIQUID FLASHING
SYSTEM WITH FLEECE
REINFORCING OVER TOP OF
TERMINATION BAR
ASSEMBLY WHERE 8" MIN.
BASE FLASHING HEIGHT IS
UNACHIEVABLE
TERMINATION BAR
ASSEMBLY,
CONTINUOUS
SEALANT
TAPERED RIGID
INSULATION
'-5
/2
V
.I .F
PREP SURFACES AND
EXTEND LIQUID
FLASHING SYSTEM UP
ONTO METAL DUCT
TRANSITION
EXISTING CAST STONE
PANEL TO REMAIN
EXISTING DUCT
PENETRATION
EXISTING SUPPORT CURB
ASSEMBLY TO REMAIN.
EXISTING CONCRETE
ROOF DECK TO REMAIN
FLASHING BASE PLY
BASE PLY
SECTION
PLAN
.5 X
1/ 4"
X
.5X.5X
1/2" MIN.
SECONDARY
SEALANT JT.
BACKER
ROD
CAST STONE
PANEL
.5X.5X
1/2" MIN.
SECONDARY
SEALANT JT.
WEEP
PRIMARY
SEALANT JT.
PRIMARY
SEALANT JT.
SEE TYP.
DETAIL AT
REGLETS
BACKER
ROD
A912
'-0
'-6
'-3
E
X
IS
T
IN
G C
U R
B
V .I .F
PROVIDE TAPERED
INSULATION CRICKET AS
SHOWN WITH 1/2" PER
1'-0" SLOPE TO GUIDE
STORM WATER
TOWARDS DRAINS.
A911
1'-0" EXISTING CURB 1'-0"
EXISTING CAST STONE
PANEL TO REMAIN
LIQUID FLASHING
SYSTEM W/ FLEECE
REINFORCING SHOWN
HATCHED WITH
DASHED BOUNDARY.
EXTEND UP ONTO
CURBS AS SHOWN IN
DETAILS.
NOTE: EXISTING DUNNAGE
AND MECHANICAL EQUIPMENT
NOT SHOWN FOR CLARITY.
NO CANTS
INSTALLED
WITHIN THIS
AREA
6" 3/4"
V .I .F
24 GA S.S. CAP
FLASHING WITH
DRIP EDGE AT
PERIMETER.
24 GA S.S. METAL COPING
ASSEMBLY
EXISTING CAST STONE
PANEL TO REMAIN
1/2" DIAMETER HOT
DIPPED GALV.
EXPANSION ANCHOR AT
24" O.C. MAX.
2X WOOD BLOCKING RIPPED TO
DIMENSIONS AND SHAPE SHOWN
CONTINUOUS 18 GA S.S.
CLEAT NAILED TO
BLOCKING AT 8" O.C.
ELASTOMERIC
SEALANT JOINT
FLASHING BASE PLY
HIGH DOMED
GASKETED
FASTENER AT 16"
O.C. MAX
LIQUID FLASHING
SYSTEM WITH
FLEECE
REINFORCING
EXISTING CAST
CONCRETE
STRUCTURE
/8
EXISTING MEMBRANE
FLASHING TO REMAIN
ON THIS SIDE
24 GA S.S. PARAPET
METAL CAP / COPING
ASSEMBLY
HIGH DOMED GASKETED
FASTENER @ 16" O.C (MAX.)
3" MIN.
TURNDOWN
SEE SECTION
DETAILS
CONT. 18 GA.
PREFINISHED
METAL CLEAT
SEE SECTION DETAILS FOR
WALL COMPOSTION (TYP.)
TORCH APPLIED BASE FLASHING
SLOPE TO ROOF
STANDING SEAM
JOINT "J8" PER
SMACNA AT
COPING PANEL
JOINT TYP.
SEAL TYP.
1/2" THICK COVER
BOARD WITH
STAGGERED JOINTS
TAPERED RIGID
INSULATION
6'-0" X 6'-0" +/-
V.I.F. - EXISTING
ROOF ROUGH
OPENING
1/2" DIAMETER HOT
DIPPED GALV.
EXPANSION ANCHOR AT
24" O.C. MAX.
3B20-GA GALVANIZED METAL
ROOF DECK CONNECTED TO
ANGLE WITH 5/8" PUDDLE
WELDS IN A 36/5 PATTERN
EXISTING
CONCRETE
ROOF DECK TO
REMAIN
CONTINUOUS GALV.
L4X4X1/4 STEEL ANGLE
AT OPENING PERIMETER
CAP SHEET
BASE PLY
PROJECT NO.
DATE
This drawing, as an instrument of service, is and shall remain the property of the Architect and shall not be reproduced, published, or used in any way without the permission of the Architect.
© Holly & Smith Architects, APAC
PROJECT MANAGER
PHASE
QUALITY CONTROL
DESCRIPTION DATENO.
1"
0" 1"½"
½"
The graphic scale at the bottom left corner of this drawing must measure 1"x1" otherwise all listed scales are null and void.
HOLLY & SMITH
ARCHITECTS
HAMMOND
T 9 8 5 . 3 4 5 . 5 2 1 0 www.hollyandsmith.com
NEW ORLEANS
T 5 0 4 . 5 8 5 . 1 3 1 5
LAFAYETTE
T 3 3 7 . 2 7 9 . 2 0 1 0
S T
A T
E P
R O
JE
C
T N
O -1
-2
-0
F
.0
A T
E I
D S
E C
O D
E -3
-0
U .N
.O P
R O
JE
C
T
S
P
.O P
U R
C H
A S
IN
G B
ID
B
T B
R e v it M o d e ls
\2
U
N O
E n g in e e ri n g A n n e x R o o f R e p la c e m e n t_ ra y h o lly a n d s m it h .c o m
.r v t
/2
/2
:5
:3
A
M
A912
ROOF DETAILS
24054
02/07/25
RK
CD
AV
BID
DOCUMENTS
L A
K E
S H
O R
E D
R
IV
E , N
E W
O R
L E
A N
S , L
A
U N
IV
E
R S
IT
Y O
F N
E W
O R
L E
A N
S
E N
G
IN
E E
R
IN
G A
N N
E X
R O
O F
R E
P L
A C
E M
E N
T
3" = 1'-0"10 DETAIL - ROOF HATCH
3/4" = 1'-0"4 DETAIL - ROOF LADDER
1 1/2" = 1'-0"6 DETAIL - PARAPET TRANSITION
1 1/2" = 1'-0"7 DETAIL - COPING STEP
3" = 1'-0"8 DETAIL - ENLARGED COPING STEP
3" = 1'-0"2 DETAIL - DUCT PENETRATION FLASHING
6" = 1'-0"3 DETAIL - CAST STONE JOINT
1/2" = 1'-0"1 ENLARGED PLAN - STAIR PRESSURE FAN
3" = 1'-0"9 DETAIL - CANOPY TIE IN
1 1/2" = 1'-0"5 DETAIL @ METAL COPING STANDING SEAM
2 ADDENDUM 02 04/24/25
1 1/2" = 1'-0"11 DETAIL - ROOF INFILL