May 6, 2025

A D D E N D U M N O. 3

Your reference is directed to SB#7661 NSU Elevator Maintenance and Inspection which is scheduled for bid openings at 2:00 p.m. Thursday, May 29th, 2025, at Northwestern State University, Natchitoches, Louisiana.

Site Visits may be requested by contacting Dale Wohletz at 318-471-1336, NSU Physical Plant Office, 998 South Jefferson, Natchitoches, LA 71497. Site visits must be performed prior to Friday, May 9th, 2025.

The following addition is being made to the above referenced solicitation:

PURPOSE OF ADDENDUM:

1) RESPOND TO VENDOR INQUIRY:

VENDOR INQUIRY: KINDLY PROVIDE A COPY OF THE LATEST STATE

INSPECTION REPORTS AS WELL AS THE CURRENT CONTRACT PRICING.

RESPONSES: SEE INSPECTION REPORTS ATTACHED.

CURRENT PRICING IS $98,640.00

This addendum is hereby officially made a part of the referenced solicitation and should be attached to the bidder’s proposal or otherwise acknowledged therein.

Failure to acknowledge addendum may result in the non-consideration of the bid submission.

If you have already submitted your proposal and this addendum causes you to revise your original bid, please indicate changes below and return to Business Affairs/Purchasing Section prior to bid opening in an envelope marked with the bid number, bid opening date, and time.

If this addendum does not cause you to revise your bid, please acknowledge receipt of the addendum by signing your name and company below and returning it in accordance with the provisions above.

Company Name Authorized Signature Date

Submitted by: Ashlee Grayson

Director of Purchasing

INSPECTION REPORT

IWO337329 | H0256 #RID#IN336287

Agency Information:

Agency Address:

Maintenance Company Information:

Maintenance Company:

Oracle Elevator : Oracle Elevator - Shreveport

Building Information:

Location Address:

East Caspari Hall 310 Sam Sibley Dr Natchitoches, LA 71457

Location ID:

735003-13

Location Contact Information:

Name: Thad Warren Title:

Phone: +13183574402 Email: warrent@nsula.edu

Inspection Information:

Inspection Date: 2/6/2024 Inspection Start Time: 12:00:00 PM Inspection End Time: 1:00:00 PM

Inspector: Voiles, Jeff || Inspection Type: Category 1 Test Inspection Result: Passed - No Violations

Re-Inspection Required: No Generator Test Performed: No Re-Inspection Maint Co Required: No

Device ID: H0256 Device Type: Hydraulic Elevator # of Landings: 3

Due Month: February Device Use: Passenger Device Designation: #1

Code Edition: Installation Date: 12/7/2011 Device Manufacturer: Schindler

Overspeed Valve? Plunger Gripper? Cat 5 Required?

Capacity: 3500 Speed: 125

Inspector Notes:

Testing Results: Relief (psi): 560, Working (psi): 180, Violation Information:

IWO337329 | H0256 #RID#IN336287

Checklist and Report for Inspection of Hydraulic Elevators ASME A17.2-2020 ID No: H0256 Device Type: Hydraulic Elevator Date: 2/6/2024 Inspection Type: Category 1 Test

Firm #: 33 Code Edition: Location Contact Name: Thad Warren

Inspected By: Voiles, Jeff || Signature: Location Contact Signature:

Notes: See ASME A17.2 for detailed Code requirements. Numbering is tied to the numbering of A 17.2 Items. OK= meets requirements; NG= doesn't meet requirements; N/A = not applicable.

1 INSIDE OF CAR OK NG N/A OK NG N/A

1.1 Door reopening device X 3.9 Floor and emergency identification numbering X

1.2 Stop Switches X 3.10 Hoistway Construction X

1.3 Operating control devices X 3.11 Hoistway smoke control X

1.4 Sills and car floor X 3.12 Pipes, wiring, and ducts X

1.5 Car lighting and receptacles X 3.13 Windows, projections, recesses, and setbacks X

1.6 Car emergency signal X 3.14 Hoistway clearances X

1.7 Car door or gate X 3.15 Multiple hoistways X

1.8 Door closing force X 3.16 Traveling cables and junction boxes X

1.9 Power closing of doors or gates X 3.17 Door and gate equipment X

1.10 Power opening of doors or gates X 3.18 Car frame and stiles X

1.11 Car vision panels and glass car doors X 3.19 Guide rails, fastenings, and equipment X

1.12 Car enclosure X 3.20 Governor rope X

1.13 Emergency exit X 3.21 Governor releasing carrier X

1.14 Ventilation X 3.22 Wire rope fastening and hitch plate X

1.15 Signs and operating device symbols X 3.23 Suspension compensation and governor systems X

1.16 Rated load, platform area, and data plate X 3.27 Crosshead data plate and rope data tags X

1.17 Standby power operation X 3.28 Counterweight and counterweight buffer X

1.18 Restricted opening of car or hoistway doors X 3.29 Counterweight safeties X

1.19 Car ride X 3.30 Speed Test X

1.20 Earthquake inspection and tests (seismic risk zone 2 or greater) X 3.31 Slack rope test - roped hydraulic elevators X 2 MACHINE ROOM 3.32 Traveling sheave-roped-hydraulic elevators installed under A17.1B-1989 and later editionsX

2.1 Access to machinery space X 3.34 Earthquake inspection and tests (seismic risk zone 2 or greater) X

2.2 Headroom X 4 OUTSIDE HOISTWAY

2.3 Lighting and receptacles X 4.1 Car platform guard X

2.4 Machinery space X 4.2 Hoistway doors X

2.5 Housekeeping X 4.3 Vision panels X

2.6 Ventilation X 4.4 Hoistway door-locking devices X

2.7 Fire extinguisher X 4.5 Access to hoistway X

2.8 Pipes, wiring, and ducts X 4.6 Power closing of hoistway doors X

2.9 Guarding of exposed auxiliary equipment X 4.7 Sequence operation X

2.10 Numbering of elevators, machines, controllers & disconnect switches X 4.8 Hoistway enclosure X

2.11 Disconnecting means and control X 4.9 Elevator parking devices X

2.12 Controller wiring, fuses, grounding, etc. X 4.10 Emergency doors in blind hoistways X

2.13 Governor, overspeed switch, and seal X 4.12 Standby power selection switch X

2.14 Code data plate X 5 PIT

2.30 Hydraulic power unit X 5.1 Pit access, lighting, stop switch & condition X

2.31 Relief valves X 5.2 Bottom clearance, runby & minimum refuge space X

2.32 Control valve X 5.4 Normal terminal stopping devices X

2.33 Tanks X 5.5 Traveling cables X

2.36 Hydraulic cylinders X 5.6 Governor-rope tension devices X

2.37 Pressure switch X 5.7 Car frame and platform X

2.38 Roped water hydraulic elevators X 5.8 Car and counterweight safeties and guiding members X

2.39 Low oil protection X 5.11 Buffers and emergency terminal speed-limiting devices X

2.40 Maintenance records X 5.12 Car buffers X

2.41 Static control X 5.13 Building members X

2.42 Earthquake inspection and tests (seismic risk zone 2 or greater) X 5.14 Supply Piping X

2.44 Auxillary power lowering operation X 5.15 Overspeed valve X

2.45 Inspection operation with open door circuits and inspection hierarchy X 5.16 Earthquake inspection and tests (seismic risk zone 2 or greater) X

5.17 Plunger gripper X

3 TOP OF CAR 6 FIREFIGHTERS' SERVICE (FEO)

3.1 Top-of-car stop switch X 6.1 A17.1b-1973 through A17.1b-1980 X

3.2 Car top light and outlet X 6.2 17.1-1981 through A17.1b-1983 X

3.3 Top-of-car operating device X 6.3 A17.1-1984 through A17.1a-1988 and A17.3 X

3.4 Top-of-car clearance, refuge space, and standard railing X 6.4 A17.1b-1989 through A17.1d-2000 X

3.5 Normal terminal stopping devices X 6.5 A 17.1-2000/644-00 X

3.6 Final and emergency terminal stopping devices X 6.6 A 17.1-2004/644-04 X

3.7 Car leveling and anticreep devices X 6.7 A17.1-2007/B44-07 X

3.8 Top emergency exit X 6.8 A17.1-2010/B44-10 X

6.9 A17.1-2013/B44-13 X

IWO372171 | H0257 #RID#IN365191

Agency Address:

Maintenance Company Information:

Maintenance Company:

Oracle Elevator : Oracle Elevator - Shreveport

Building Information:

Location Address:

Student Services Center 306 Sam SIbley Dr Natchitoches, LA 71457

Location ID:

735003-90

Location Contact Information:

Name: Thad Warren Title:

Phone: +13183574402 Email: warrent@nsula.edu

Inspection Information:

Inspection Date: 8/19/2024 Inspection Start Time: 4:30:00 PM Inspection End Time: 5:00:00 PM

Inspector: Voiles, Jeff || Inspection Type: Routine/Periodic Inspection Result: Passed - Violations

Re-Inspection Required: No Generator Test Performed: No Re-Inspection Maint Co Required: No

Device ID: H0257 Device Type: Hydraulic Elevator # of Landings: 3

Due Month: February Device Use: Passenger Device Designation: #1

Code Edition: Installation Date: 7/6/2011 Device Manufacturer: Schindler

Overspeed Valve? Plunger Gripper? Cat 5 Required?

Capacity: 3500 Speed: 125

Inspector Notes:

Testing Results:

Violation Information:

Previous Violations Previous Violation Inspector Comments Corrected?

2.5 Housekeeping 8.6.4.8 Clean the Elevator Machine room No

1.18 Restricted opening of car or hoistway doors 8.6.4.13 Repair car door restrictor No

5.1 Pit access; lighting; stop switch; and condition 8.6.4.7 Clean the Elevator pit No

IWO372171 | H0257 #RID#IN365191

ID No: H0257 Device Type: Hydraulic Elevator Date: 8/19/2024 Inspection Type: Routine/Periodic

Firm #: 33 Code Edition: Location Contact Name: Thad Warren

Inspected By: Voiles, Jeff || Signature: Location Contact Signature:

Notes: See ASME A17.2 for detailed Code requirements. Numbering is tied to the numbering of A 17.2 Items. OK= meets requirements; NG= doesn't meet requirements; N/A = not applicable.

1 INSIDE OF CAR OK NG N/A OK NG N/A

1.1 Door reopening device X 3.9 Floor and emergency identification numbering X

1.2 Stop Switches X 3.10 Hoistway Construction X

1.3 Operating control devices X 3.11 Hoistway smoke control X

1.4 Sills and car floor X 3.12 Pipes, wiring, and ducts X

1.5 Car lighting and receptacles X 3.13 Windows, projections, recesses, and setbacks X

1.6 Car emergency signal X 3.14 Hoistway clearances X

1.7 Car door or gate X 3.15 Multiple hoistways X

1.8 Door closing force X 3.16 Traveling cables and junction boxes X

1.9 Power closing of doors or gates X 3.17 Door and gate equipment X

1.10 Power opening of doors or gates X 3.18 Car frame and stiles X

1.11 Car vision panels and glass car doors X 3.19 Guide rails, fastenings, and equipment X

1.12 Car enclosure X 3.20 Governor rope X

1.13 Emergency exit X 3.21 Governor releasing carrier X

1.14 Ventilation X 3.22 Wire rope fastening and hitch plate X

1.15 Signs and operating device symbols X 3.23 Suspension compensation and governor systems X

1.16 Rated load, platform area, and data plate X 3.27 Crosshead data plate and rope data tags X

1.17 Standby power operation X 3.28 Counterweight and counterweight buffer X

1.18 Restricted opening of car or hoistway doors X 3.29 Counterweight safeties X

1.19 Car ride X 3.30 Speed Test X

1.20 Earthquake inspection and tests (seismic risk zone 2 or greater) X 3.31 Slack rope test - roped hydraulic elevators X 2 MACHINE ROOM 3.32 Traveling sheave-roped-hydraulic elevators installed under A17.1B-1989 and later editionsX

2.1 Access to machinery space X 3.34 Earthquake inspection and tests (seismic risk zone 2 or greater) X

2.2 Headroom X 4 OUTSIDE HOISTWAY

2.3 Lighting and receptacles X 4.1 Car platform guard X

2.4 Machinery space X 4.2 Hoistway doors X

2.5 Housekeeping X 4.3 Vision panels X

2.6 Ventilation X 4.4 Hoistway door-locking devices X

2.7 Fire extinguisher X 4.5 Access to hoistway X

2.8 Pipes, wiring, and ducts X 4.6 Power closing of hoistway doors X

2.9 Guarding of exposed auxiliary equipment X 4.7 Sequence operation X

2.10 Numbering of elevators, machines, controllers & disconnect switches X 4.8 Hoistway enclosure X

2.11 Disconnecting means and control X 4.9 Elevator parking devices X

2.12 Controller wiring, fuses, grounding, etc. X 4.10 Emergency doors in blind hoistways X

2.13 Governor, overspeed switch, and seal X 4.12 Standby power selection switch X

2.14 Code data plate X 5 PIT

2.30 Hydraulic power unit X 5.1 Pit access, lighting, stop switch & condition X

2.31 Relief valves X 5.2 Bottom clearance, runby & minimum refuge space X

2.32 Control valve X 5.4 Normal terminal stopping devices X

2.33 Tanks X 5.5 Traveling cables X

2.36 Hydraulic cylinders X 5.6 Governor-rope tension devices X

2.37 Pressure switch X 5.7 Car frame and platform X

2.38 Roped water hydraulic elevators X 5.8 Car and counterweight safeties and guiding members X

2.39 Low oil protection X 5.11 Buffers and emergency terminal speed-limiting devices X

2.40 Maintenance records X 5.12 Car buffers X

2.41 Static control X 5.13 Building members X

2.42 Earthquake inspection and tests (seismic risk zone 2 or greater) X 5.14 Supply Piping X

2.44 Auxillary power lowering operation X 5.15 Overspeed valve X

2.45 Inspection operation with open door circuits and inspection hierarchy X 5.16 Earthquake inspection and tests (seismic risk zone 2 or greater) X

5.17 Plunger gripper X

3 TOP OF CAR 6 FIREFIGHTERS' SERVICE (FEO)

3.1 Top-of-car stop switch X 6.1 A17.1b-1973 through A17.1b-1980 X

3.2 Car top light and outlet X 6.2 17.1-1981 through A17.1b-1983 X

3.3 Top-of-car operating device X 6.3 A17.1-1984 through A17.1a-1988 and A17.3 X

3.4 Top-of-car clearance, refuge space, and standard railing X 6.4 A17.1b-1989 through A17.1d-2000 X

3.5 Normal terminal stopping devices X 6.5 A 17.1-2000/644-00 X

3.6 Final and emergency terminal stopping devices X 6.6 A 17.1-2004/644-04 X

3.7 Car leveling and anticreep devices X 6.7 A17.1-2007/B44-07 X

IWO372171 | H0258 #RID#IN365191

Agency Address:

Maintenance Company Information:

Maintenance Company:

Oracle Elevator : Oracle Elevator - Shreveport

Building Information:

Location Address:

Family And Consumer Sciences 342 Caspari St.

Natchitoches, LA 71457

Location ID:

735003-4

Location Contact Information:

Name: Thad Warren Title:

Phone: +13183574402 Email: warrent@nsula.edu

Inspection Information:

Inspection Date: 8/19/2024 Inspection Start Time: 4:00:00 PM Inspection End Time: 4:30:00 PM

Inspector: Voiles, Jeff || Inspection Type: Routine/Periodic Inspection Result: Passed - Violations

Re-Inspection Required: No Generator Test Performed: No Re-Inspection Maint Co Required: No

Device ID: H0258 Device Type: Hydraulic Elevator # of Landings: 2

Due Month: February Device Use: Passenger Device Designation: #1

Code Edition: Installation Date: 5/6/2003 Device Manufacturer: TKE

Overspeed Valve? Plunger Gripper? Cat 5 Required?

Capacity: 2000 Speed: 100

Inspector Notes:

Testing Results:

Violation Information:

Previous Violations Previous Violation Inspector Comments Corrected?

5.1 Pit access; lighting; stop switch; and condition A17.I- 3.18.3.7 Clean oil from the elevator pit area No

1.3 Operating control devices 2.14.7.1.3 Repair In car emergency light No

IWO372171 | H0258 #RID#IN365191

ID No: H0258 Device Type: Hydraulic Elevator Date: 8/19/2024 Inspection Type: Routine/Periodic

Firm #: 33 Code Edition: Location Contact Name: Thad Warren

Inspected By: Voiles, Jeff || Signature: Location Contact Signature:

Notes: See ASME A17.2 for detailed Code requirements. Numbering is tied to the numbering of A 17.2 Items. OK= meets requirements; NG= doesn't meet requirements; N/A = not applicable.

1 INSIDE OF CAR OK NG N/A OK NG N/A

1.1 Door reopening device X 3.9 Floor and emergency identification numbering X

1.2 Stop Switches X 3.10 Hoistway Construction X

1.3 Operating control devices X 3.11 Hoistway smoke control X

1.4 Sills and car floor X 3.12 Pipes, wiring, and ducts X

1.5 Car lighting and receptacles X 3.13 Windows, projections, recesses, and setbacks X

1.6 Car emergency signal X 3.14 Hoistway clearances X

1.7 Car door or gate X 3.15 Multiple hoistways X

1.8 Door closing force X 3.16 Traveling cables and junction boxes X

1.9 Power closing of doors or gates X 3.17 Door and gate equipment X

1.10 Power opening of doors or gates X 3.18 Car frame and stiles X

1.11 Car vision panels and glass car doors X 3.19 Guide rails, fastenings, and equipment X

1.12 Car enclosure X 3.20 Governor rope X

1.13 Emergency exit X 3.21 Governor releasing carrier X

1.14 Ventilation X 3.22 Wire rope fastening and hitch plate X

1.15 Signs and operating device symbols X 3.23 Suspension compensation and governor systems X

1.16 Rated load, platform area, and data plate X 3.27 Crosshead data plate and rope data tags X

1.17 Standby power operation X 3.28 Counterweight and counterweight buffer X

1.18 Restricted opening of car or hoistway doors X 3.29 Counterweight safeties X

1.19 Car ride X 3.30 Speed Test X

1.20 Earthquake inspection and tests (seismic risk zone 2 or greater) X 3.31 Slack rope test - roped hydraulic elevators X 2 MACHINE ROOM 3.32 Traveling sheave-roped-hydraulic elevators installed under A17.1B-1989 and later editionsX

2.1 Access to machinery space X 3.34 Earthquake inspection and tests (seismic risk zone 2 or greater) X

2.2 Headroom X 4 OUTSIDE HOISTWAY

2.3 Lighting and receptacles X 4.1 Car platform guard X

2.4 Machinery space X 4.2 Hoistway doors X

2.5 Housekeeping X 4.3 Vision panels X

2.6 Ventilation X 4.4 Hoistway door-locking devices X

2.7 Fire extinguisher X 4.5 Access to hoistway X

2.8 Pipes, wiring, and ducts X 4.6 Power closing of hoistway doors X

2.9 Guarding of exposed auxiliary equipment X 4.7 Sequence operation X

2.10 Numbering of elevators, machines, controllers & disconnect switches X 4.8 Hoistway enclosure X

2.11 Disconnecting means and control X 4.9 Elevator parking devices X

2.12 Controller wiring, fuses, grounding, etc. X 4.10 Emergency doors in blind hoistways X

2.13 Governor, overspeed switch, and seal X 4.12 Standby power selection switch X

2.14 Code data plate X 5 PIT

2.30 Hydraulic power unit X 5.1 Pit access, lighting, stop switch & condition X

2.31 Relief valves X 5.2 Bottom clearance, runby & minimum refuge space X

2.32 Control valve X 5.4 Normal terminal stopping devices X

2.33 Tanks X 5.5 Traveling cables X

2.36 Hydraulic cylinders X 5.6 Governor-rope tension devices X

2.37 Pressure switch X 5.7 Car frame and platform X

2.38 Roped water hydraulic elevators X 5.8 Car and counterweight safeties and guiding members X

2.39 Low oil protection X 5.11 Buffers and emergency terminal speed-limiting devices X

2.40 Maintenance records X 5.12 Car buffers X

2.41 Static control X 5.13 Building members X

2.42 Earthquake inspection and tests (seismic risk zone 2 or greater) X 5.14 Supply Piping X

2.44 Auxillary power lowering operation X 5.15 Overspeed valve X

2.45 Inspection operation with open door circuits and inspection hierarchy X 5.16 Earthquake inspection and tests (seismic risk zone 2 or greater) X

5.17 Plunger gripper X

3 TOP OF CAR 6 FIREFIGHTERS' SERVICE (FEO)

3.1 Top-of-car stop switch X 6.1 A17.1b-1973 through A17.1b-1980 X

3.2 Car top light and outlet X 6.2 17.1-1981 through A17.1b-1983 X

3.3 Top-of-car operating device X 6.3 A17.1-1984 through A17.1a-1988 and A17.3 X

3.4 Top-of-car clearance, refuge space, and standard railing X 6.4 A17.1b-1989 through A17.1d-2000 X

3.5 Normal terminal stopping devices X 6.5 A 17.1-2000/644-00 X

3.6 Final and emergency terminal stopping devices X 6.6 A 17.1-2004/644-04 X

3.7 Car leveling and anticreep devices X 6.7 A17.1-2007/B44-07 X

IWO372171 | H0260 #RID#IN365191

Agency Address:

Maintenance Company Information:

Maintenance Company:

Oracle Elevator : Oracle Elevator - Shreveport

Building Information:

Location Address:

Morrison Hall 326 Caspari St.

Natchitoches, LA 71457

Location ID:

735003-1

Location Contact Information:

Name: Thad Warren Title:

Phone: +13183574402 Email: warrent@nsula.edu

Inspection Information:

Inspection Date: 8/20/2024 Inspection Start Time: 4:00:00 PM Inspection End Time: 5:00:00 PM

Inspector: Voiles, Jeff || Inspection Type: Routine/Periodic Inspection Result: Passed - Violations

Re-Inspection Required: No Generator Test Performed: No Re-Inspection Maint Co Required: No

Device ID: H0260 Device Type: Hydraulic Elevator # of Landings: 2

Due Month: February Device Use: Passenger Device Designation: #1

Code Edition: Installation Date: 7/6/2003 Device Manufacturer: TKE

Overspeed Valve? Plunger Gripper? Cat 5 Required?

Capacity: 2000 Speed: 100

Inspector Notes:

Testing Results:

Violation Information:

Previous Violations Previous Violation Inspector Comments Corrected?

1.18 Restricted opening of car or hoistway doors A17.1- 8.6.4.13 repair elevator car door restrictor No

5.1 Pit access; lighting; stop switch; and condition A17.1- 3.18.3.7 Clean the oil from elevator pit area No

1.3 Operating control devices 2.14.7.1.3 Repair In car emergency lights No

5.1 Pit access; lighting; stop switch; and condition 2.2.2.6 Replace missing cover over sump hole located in elevator pit No

IWO372171 | H0260 #RID#IN365191

ID No: H0260 Device Type: Hydraulic Elevator Date: 8/20/2024 Inspection Type: Routine/Periodic

Firm #: 33 Code Edition: Location Contact Name: Thad Warren

Inspected By: Voiles, Jeff || Signature: Location Contact Signature:

Notes: See ASME A17.2 for detailed Code requirements. Numbering is tied to the numbering of A 17.2 Items. OK= meets requirements; NG= doesn't meet requirements; N/A = not applicable.

1 INSIDE OF CAR OK NG N/A OK NG N/A

1.1 Door reopening device X 3.9 Floor and emergency identification numbering X

1.2 Stop Switches X 3.10 Hoistway Construction X

1.3 Operating control devices X 3.11 Hoistway smoke control X

1.4 Sills and car floor X 3.12 Pipes, wiring, and ducts X

1.5 Car lighting and receptacles X 3.13 Windows, projections, recesses, and setbacks X

1.6 Car emergency signal X 3.14 Hoistway clearances X

1.7 Car door or gate X 3.15 Multiple hoistways X

1.8 Door closing force X 3.16 Traveling cables and junction boxes X

1.9 Power closing of doors or gates X 3.17 Door and gate equipment X

1.10 Power opening of doors or gates X 3.18 Car frame and stiles X

1.11 Car vision panels and glass car doors X 3.19 Guide rails, fastenings, and equipment X

1.12 Car enclosure X 3.20 Governor rope X

1.13 Emergency exit X 3.21 Governor releasing carrier X

1.14 Ventilation X 3.22 Wire rope fastening and hitch plate X

1.15 Signs and operating device symbols X 3.23 Suspension compensation and governor systems X

1.16 Rated load, platform area, and data plate X 3.27 Crosshead data plate and rope data tags X

1.17 Standby power operation X 3.28 Counterweight and counterweight buffer X

1.18 Restricted opening of car or hoistway doors X 3.29 Counterweight safeties X

1.19 Car ride X 3.30 Speed Test X

1.20 Earthquake inspection and tests (seismic risk zone 2 or greater) X 3.31 Slack rope test - roped hydraulic elevators X 2 MACHINE ROOM 3.32 Traveling sheave-roped-hydraulic elevators installed under A17.1B-1989 and later editionsX

2.1 Access to machinery space X 3.34 Earthquake inspection and tests (seismic risk zone 2 or greater) X

2.2 Headroom X 4 OUTSIDE HOISTWAY

2.3 Lighting and receptacles X 4.1 Car platform guard X

2.4 Machinery space X 4.2 Hoistway doors X

2.5 Housekeeping X 4.3 Vision panels X

2.6 Ventilation X 4.4 Hoistway door-locking devices X

2.7 Fire extinguisher X 4.5 Access to hoistway X

2.8 Pipes, wiring, and ducts X 4.6 Power closing of hoistway doors X

2.9 Guarding of exposed auxiliary equipment X 4.7 Sequence operation X

2.10 Numbering of elevators, machines, controllers & disconnect switches X 4.8 Hoistway enclosure X

2.11 Disconnecting means and control X 4.9 Elevator parking devices X

2.12 Controller wiring, fuses, grounding, etc. X 4.10 Emergency doors in blind hoistways X

2.13 Governor, overspeed switch, and seal X 4.12 Standby power selection switch X

2.14 Code data plate X 5 PIT

2.30 Hydraulic power unit X 5.1 Pit access, lighting, stop switch & condition X

2.31 Relief valves X 5.2 Bottom clearance, runby & minimum refuge space X

2.32 Control valve X 5.4 Normal terminal stopping devices X

2.33 Tanks X 5.5 Traveling cables X

2.36 Hydraulic cylinders X 5.6 Governor-rope tension devices X

2.37 Pressure switch X 5.7 Car frame and platform X

2.38 Roped water hydraulic elevators X 5.8 Car and counterweight safeties and guiding members X

2.39 Low oil protection X 5.11 Buffers and emergency terminal speed-limiting devices X

2.40 Maintenance records X 5.12 Car buffers X

2.41 Static control X 5.13 Building members X

2.42 Earthquake inspection and tests (seismic risk zone 2 or greater) X 5.14 Supply Piping X

2.44 Auxillary power lowering operation X 5.15 Overspeed valve X

2.45 Inspection operation with open door circuits and inspection hierarchy X 5.16 Earthquake inspection and tests (seismic risk zone 2 or greater) X

5.17 Plunger gripper X

3 TOP OF CAR 6 FIREFIGHTERS' SERVICE (FEO)

3.1 Top-of-car stop switch X 6.1 A17.1b-1973 through A17.1b-1980 X

3.2 Car top light and outlet X 6.2 17.1-1981 through A17.1b-1983 X

3.3 Top-of-car operating device X 6.3 A17.1-1984 through A17.1a-1988 and A17.3 X

3.4 Top-of-car clearance, refuge space, and standard railing X 6.4 A17.1b-1989 through A17.1d-2000 X

3.5 Normal terminal stopping devices X 6.5 A 17.1-2000/644-00 X

3.6 Final and emergency terminal stopping devices X 6.6 A 17.1-2004/644-04 X

3.7 Car leveling and anticreep devices X 6.7 A17.1-2007/B44-07 X

IWO372171 | H0263 #RID#IN365191

Agency Address:

Maintenance Company Information:

Maintenance Company:

Oracle Elevator : Oracle Elevator - Shreveport

Building Information:

Location Address:

Warren Easton Hall 136 Caldwell Dr Natchitoches, LA 71457

Location ID:

735003-19

Location Contact Information:

Name: Thad Warren Title:

Phone: +13183574402 Email: warrent@nsula.edu

Inspection Information:

Inspection Date: 8/20/2024 Inspection Start Time: 12:00:00 PM Inspection End Time: 12:30:00 PM

Inspector: Voiles, Jeff || Inspection Type: Routine/Periodic Inspection Result: Passed - Violations

Re-Inspection Required: No Generator Test Performed: No Re-Inspection Maint Co Required: No

Device ID: H0263 Device Type: Hydraulic Elevator # of Landings: 4

Due Month: February Device Use: Passenger Device Designation: #1

Code Edition: Installation Date: 10/8/1988 Device Manufacturer: Wiggins

Overspeed Valve? Plunger Gripper? Cat 5 Required?

Capacity: 2500 Speed: 125

Inspector Notes:

Testing Results:

Violation Information:

Previous Violations Previous Violation Inspector Comments Corrected?

1.3 Operating control devices 2.27.1.13 Repair in car phone

2.27.1 Repair in car alarm

No

5.1 Pit access; lighting; stop switch; and condition 8.6.4.7 Clean the elevator pit No

1.3 Operating control devices A17.1- 2.27.1.13 Repair emergency phone located inside of elevator No

IWO372171 | H0263 #RID#IN365191

ID No: H0263 Device Type: Hydraulic Elevator Date: 8/20/2024 Inspection Type: Routine/Periodic

Firm #: 33 Code Edition: Location Contact Name: Thad Warren

Inspected By: Voiles, Jeff || Signature: Location Contact Signature:

Notes: See ASME A17.2 for detailed Code requirements. Numbering is tied to the numbering of A 17.2 Items. OK= meets requirements; NG= doesn't meet requirements; N/A = not applicable.

1 INSIDE OF CAR OK NG N/A OK NG N/A

1.1 Door reopening device X 3.9 Floor and emergency identification numbering X

1.2 Stop Switches X 3.10 Hoistway Construction X

1.3 Operating control devices X 3.11 Hoistway smoke control X

1.4 Sills and car floor X 3.12 Pipes, wiring, and ducts X

1.5 Car lighting and receptacles X 3.13 Windows, projections, recesses, and setbacks X

1.6 Car emergency signal X 3.14 Hoistway clearances X

1.7 Car door or gate X 3.15 Multiple hoistways X

1.8 Door closing force X 3.16 Traveling cables and junction boxes X

1.9 Power closing of doors or gates X 3.17 Door and gate equipment X

1.10 Power opening of doors or gates X 3.18 Car frame and stiles X

1.11 Car vision panels and glass car doors X 3.19 Guide rails, fastenings, and equipment X

1.12 Car enclosure X 3.20 Governor rope X

1.13 Emergency exit X 3.21 Governor releasing carrier X

1.14 Ventilation X 3.22 Wire rope fastening and hitch plate X

1.15 Signs and operating device symbols X 3.23 Suspension compensation and governor systems X

1.16 Rated load, platform area, and data plate X 3.27 Crosshead data plate and rope data tags X

1.17 Standby power operation X 3.28 Counterweight and counterweight buffer X

1.18 Restricted opening of car or hoistway doors X 3.29 Counterweight safeties X

1.19 Car ride X 3.30 Speed Test X

1.20 Earthquake inspection and tests (seismic risk zone 2 or greater) X 3.31 Slack rope test - roped hydraulic elevators X 2 MACHINE ROOM 3.32 Traveling sheave-roped-hydraulic elevators installed under A17.1B-1989 and later editionsX

2.1 Access to machinery space X 3.34 Earthquake inspection and tests (seismic risk zone 2 or greater) X

2.2 Headroom X 4 OUTSIDE HOISTWAY

2.3 Lighting and receptacles X 4.1 Car platform guard X

2.4 Machinery space X 4.2 Hoistway doors X

2.5 Housekeeping X 4.3 Vision panels X

2.6 Ventilation X 4.4 Hoistway door-locking devices X

2.7 Fire extinguisher X 4.5 Access to hoistway X

2.8 Pipes, wiring, and ducts X 4.6 Power closing of hoistway doors X

2.9 Guarding of exposed auxiliary equipment X 4.7 Sequence operation X

2.10 Numbering of elevators, machines, controllers & disconnect switches X 4.8 Hoistway enclosure X

2.11 Disconnecting means and control X 4.9 Elevator parking devices X

2.12 Controller wiring, fuses, grounding, etc. X 4.10 Emergency doors in blind hoistways X

2.13 Governor, overspeed switch, and seal X 4.12 Standby power selection switch X

2.14 Code data plate X 5 PIT

2.30 Hydraulic power unit X 5.1 Pit access, lighting, stop switch & condition X

2.31 Relief valves X 5.2 Bottom clearance, runby & minimum refuge space X

2.32 Control valve X 5.4 Normal terminal stopping devices X

2.33 Tanks X 5.5 Traveling cables X

2.36 Hydraulic cylinders X 5.6 Governor-rope tension devices X

2.37 Pressure switch X 5.7 Car frame and platform X

2.38 Roped water hydraulic elevators X 5.8 Car and counterweight safeties and guiding members X

2.39 Low oil protection X 5.11 Buffers and emergency terminal speed-limiting devices X

2.40 Maintenance records X 5.12 Car buffers X

2.41 Static control X 5.13 Building members X

2.42 Earthquake inspection and tests (seismic risk zone 2 or greater) X 5.14 Supply Piping X

2.44 Auxillary power lowering operation X 5.15 Overspeed valve X

2.45 Inspection operation with open door circuits and inspection hierarchy X 5.16 Earthquake inspection and tests (seismic risk zone 2 or greater) X

5.17 Plunger gripper X

3 TOP OF CAR 6 FIREFIGHTERS' SERVICE (FEO)

3.1 Top-of-car stop switch X 6.1 A17.1b-1973 through A17.1b-1980 X

3.2 Car top light and outlet X 6.2 17.1-1981 through A17.1b-1983 X

3.3 Top-of-car operating device X 6.3 A17.1-1984 through A17.1a-1988 and A17.3 X

3.4 Top-of-car clearance, refuge space, and standard railing X 6.4 A17.1b-1989 through A17.1d-2000 X

3.5 Normal terminal stopping devices X 6.5 A 17.1-2000/644-00 X

3.6 Final and emergency terminal stopping devices X 6.6 A 17.1-2004/644-04 X

3.7 Car leveling and anticreep devices X 6.7 A17.1-2007/B44-07 X

IWO372171 | H0264 #RID#IN365191

Agency Address:

Maintenance Company Information:

Maintenance Company:

Oracle Elevator : Oracle Elevator - Shreveport

Building Information:

Location Address:

Lee A. Nelson Hall 642 Univesity Parkway Natchitoches, LA 71457

Location ID:

735003-6

Location Contact Information:

Name: Thad Warren Title:

Phone: +13183574402 Email: warrent@nsula.edu

Inspection Information:

Inspection Date: 8/20/2024 Inspection Start Time: 2:30:00 PM Inspection End Time: 3:00:00 PM

Inspector: Voiles, Jeff || Inspection Type: Routine/Periodic Inspection Result: Passed - Violations

Re-Inspection Required: No Generator Test Performed: No Re-Inspection Maint Co Required: No

Device ID: H0264 Device Type: Hydraulic Elevator # of Landings: 3

Due Month: February Device Use: Passenger Device Designation: #1

Code Edition: 1998 - A17.1b Installation Date: 10/4/2000 Device Manufacturer: TKE

Overspeed Valve? Plunger Gripper? Cat 5 Required?

Capacity: 2100 Speed: 100

Inspector Notes:

Testing Results:

Violation Information:

New Violations Violation Inspector Comments

1.3 Operating control devices 2.7.9.3- Repair emergency phone located inside of elevator Previous Violations Previous Violation Inspector Comments Corrected?

5.1 Pit access; lighting; stop switch; and condition A17.1- repair light located in the elevator pit area No

3.4 Top-of-car clearance; refuge space; and standard

railing

Some areas of the hoistway has fall hazards, Recommend to provide car top hand rails

No

1.3 Operating control devices 2.14.7.1.3 Repair repair in car Emergency lights No

2.5 Housekeeping 8.6.4.8 Clean debris and stored materials from elevator machine room No

IWO372171 | H0264 #RID#IN365191

ID No: H0264 Device Type: Hydraulic Elevator Date: 8/20/2024 Inspection Type: Routine/Periodic

Firm #: 33 Code Edition: 1998 - A17.1b Location Contact Name: Thad Warren

Inspected By: Voiles, Jeff || Signature: Location Contact Signature:

Notes: See ASME A17.2 for detailed Code requirements. Numbering is tied to the numbering of A 17.2 Items. OK= meets requirements; NG= doesn't meet requirements; N/A = not applicable.

1 INSIDE OF CAR OK NG N/A OK NG N/A

1.1 Door reopening device X 3.9 Floor and emergency identification numbering X

1.2 Stop Switches X 3.10 Hoistway Construction X

1.3 Operating control devices X 3.11 Hoistway smoke control X

1.4 Sills and car floor X 3.12 Pipes, wiring, and ducts X

1.5 Car lighting and receptacles X 3.13 Windows, projections, recesses, and setbacks X

1.6 Car emergency signal X 3.14 Hoistway clearances X

1.7 Car door or gate X 3.15 Multiple hoistways X

1.8 Door closing force X 3.16 Traveling cables and junction boxes X

1.9 Power closing of doors or gates X 3.17 Door and gate equipment X

1.10 Power opening of doors or gates X 3.18 Car frame and stiles X

1.11 Car vision panels and glass car doors X 3.19 Guide rails, fastenings, and equipment X

1.12 Car enclosure X 3.20 Governor rope X

1.13 Emergency exit X 3.21 Governor releasing carrier X

1.14 Ventilation X 3.22 Wire rope fastening and hitch plate X

1.15 Signs and operating device symbols X 3.23 Suspension compensation and governor systems X

1.16 Rated load, platform area, and data plate X 3.27 Crosshead data plate and rope data tags X

1.17 Standby power operation X 3.28 Counterweight and counterweight buffer X

1.18 Restricted opening of car or hoistway doors X 3.29 Counterweight safeties X

1.19 Car ride X 3.30 Speed Test X

1.20 Earthquake inspection and tests (seismic risk zone 2 or greater) X 3.31 Slack rope test - roped hydraulic elevators X 2 MACHINE ROOM 3.32 Traveling sheave-roped-hydraulic elevators installed under A17.1B-1989 and later editionsX

2.1 Access to machinery space X 3.34 Earthquake inspection and tests (seismic risk zone 2 or greater) X

2.2 Headroom X 4 OUTSIDE HOISTWAY

2.3 Lighting and receptacles X 4.1 Car platform guard X

2.4 Machinery space X 4.2 Hoistway doors X

2.5 Housekeeping X 4.3 Vision panels X

2.6 Ventilation X 4.4 Hoistway door-locking devices X

2.7 Fire extinguisher X 4.5 Access to hoistway X

2.8 Pipes, wiring, and ducts X 4.6 Power closing of hoistway doors X

2.9 Guarding of exposed auxiliary equipment X 4.7 Sequence operation X

2.10 Numbering of elevators, machines, controllers & disconnect switches X 4.8 Hoistway enclosure X

2.11 Disconnecting means and control X 4.9 Elevator parking devices X

2.12 Controller wiring, fuses, grounding, etc. X 4.10 Emergency doors in blind hoistways X

2.13 Governor, overspeed switch, and seal X 4.12 Standby power selection switch X

2.14 Code data plate X 5 PIT

2.30 Hydraulic power unit X 5.1 Pit access, lighting, stop switch & condition X

2.31 Relief valves X 5.2 Bottom clearance, runby & minimum refuge space X

2.32 Control valve X 5.4 Normal terminal stopping devices X

2.33 Tanks X 5.5 Traveling cables X

2.36 Hydraulic cylinders X 5.6 Governor-rope tension devices X

2.37 Pressure switch X 5.7 Car frame and platform X

2.38 Roped water hydraulic elevators X 5.8 Car and counterweight safeties and guiding members X

2.39 Low oil protection X 5.11 Buffers and emergency terminal speed-limiting devices X

2.40 Maintenance records X 5.12 Car buffers X

2.41 Static control X 5.13 Building members X

2.42 Earthquake inspection and tests (seismic risk zone 2 or greater) X 5.14 Supply Piping X

2.44 Auxillary power lowering operation X 5.15 Overspeed valve X

2.45 Inspection operation with open door circuits and inspection hierarchy X 5.16 Earthquake inspection and tests (seismic risk zone 2 or greater) X

5.17 Plunger gripper X

3 TOP OF CAR 6 FIREFIGHTERS' SERVICE (FEO)

3.1 Top-of-car stop switch X 6.1 A17.1b-1973 through A17.1b-1980 X

3.2 Car top light and outlet X 6.2 17.1-1981 through A17.1b-1983 X

3.3 Top-of-car operating device X 6.3 A17.1-1984 through A17.1a-1988 and A17.3 X

3.4 Top-of-car clearance, refuge space, and standard railing X 6.4 A17.1b-1989 through A17.1d-2000 X

3.5 Normal terminal stopping devices X 6.5 A 17.1-2000/644-00 X

3.6 Final and emergency terminal stopping devices X 6.6 A 17.1-2004/644-04 X

3.7 Car leveling and anticreep devices X 6.7 A17.1-2007/B44-07 X

IWO372171 | H0265 #RID#IN365191

Agency Address:

Maintenance Company Information:

Maintenance Company:

Oracle Elevator : Oracle Elevator - Shreveport

Building Information:

Location Address:

Russel Hall 125 Central Ave Natchitoches, LA 71457

Location ID:

735003-20

Location Contact Information:

Name: Thad Warren Title:

Phone: +13183574402 Email: warrent@nsula.edu

Inspection Information:

Inspection Date: 8/20/2024 Inspection Start Time: 11:15:00 AM Inspection End Time: 11:30:00 AM

Inspector: Voiles, Jeff || Inspection Type: Routine/Periodic Inspection Result: Passed - Violations

Re-Inspection Required: No Generator Test Performed: No Re-Inspection Maint Co Required: No

Device ID: H0265 Device Type: Hydraulic Elevator # of Landings: 3

Due Month: February Device Use: Passenger Device Designation: #1

Code Edition: Installation Date: 7/8/1996 Device Manufacturer: Dover

Overspeed Valve? Plunger Gripper? Cat 5 Required?

Capacity: 2100 Speed: 125

Inspector Notes:

Testing Results:

Violation Information:

Previous Violations Previous Violation Inspector Comments Corrected?

5.1 Pit access; lighting; stop switch; and condition A17.1- Provide a GFI type receptacle located in elevator pit area No

IWO372171 | H0265 #RID#IN365191

ID No: H0265 Device Type: Hydraulic Elevator Date: 8/20/2024 Inspection Type: Routine/Periodic

Firm #: 33 Code Edition: Location Contact Name: Thad Warren

Inspected By: Voiles, Jeff || Signature: Location Contact Signature:

Notes: See ASME A17.2 for detailed Code requirements. Numbering is tied to the numbering of A 17.2 Items. OK= meets requirements; NG= doesn't meet requirements; N/A = not applicable.

1 INSIDE OF CAR OK NG N/A OK NG N/A

1.1 Door reopening device X 3.9 Floor and emergency identification numbering X

1.2 Stop Switches X 3.10 Hoistway Construction X

1.3 Operating control devices X 3.11 Hoistway smoke control X

1.4 Sills and car floor X 3.12 Pipes, wiring, and ducts X

1.5 Car lighting and receptacles X 3.13 Windows, projections, recesses, and setbacks X

1.6 Car emergency signal X 3.14 Hoistway clearances X

1.7 Car door or gate X 3.15 Multiple hoistways X

1.8 Door closing force X 3.16 Traveling cables and junction boxes X

1.9 Power closing of doors or gates X 3.17 Door and gate equipment X

1.10 Power opening of doors or gates X 3.18 Car frame and stiles X

1.11 Car vision panels and glass car doors X 3.19 Guide rails, fastenings, and equipment X

1.12 Car enclosure X 3.20 Governor rope X

1.13 Emergency exit X 3.21 Governor releasing carrier X

1.14 Ventilation X 3.22 Wire rope fastening and hitch plate X

1.15 Signs and operating device symbols X 3.23 Suspension compensation and governor systems X

1.16 Rated load, platform area, and data plate X 3.27 Crosshead data plate and rope data tags X

1.17 Standby power operation X 3.28 Counterweight and counterweight buffer X

1.18 Restricted opening of car or hoistway doors X 3.29 Counterweight safeties X

1.19 Car ride X 3.30 Speed Test X

1.20 Earthquake inspection and tests (seismic risk zone 2 or greater) X 3.31 Slack rope test - roped hydraulic elevators X 2 MACHINE ROOM 3.32 Traveling sheave-roped-hydraulic elevators installed under A17.1B-1989 and later editionsX

2.1 Access to machinery space X 3.34 Earthquake inspection and tests (seismic risk zone 2 or greater) X

2.2 Headroom X 4 OUTSIDE HOISTWAY

2.3 Lighting and receptacles X 4.1 Car platform guard X

2.4 Machinery space X 4.2 Hoistway doors X

2.5 Housekeeping X 4.3 Vision panels X

2.6 Ventilation X 4.4 Hoistway door-locking devices X

2.7 Fire extinguisher X 4.5 Access to hoistway X

2.8 Pipes, wiring, and ducts X 4.6 Power closing of hoistway doors X

2.9 Guarding of exposed auxiliary equipment X 4.7 Sequence operation X

2.10 Numbering of elevators, machines, controllers & disconnect switches X 4.8 Hoistway enclosure X

2.11 Disconnecting means and control X 4.9 Elevator parking devices X

2.12 Controller wiring, fuses, grounding, etc. X 4.10 Emergency doors in blind hoistways X

2.13 Governor, overspeed switch, and seal X 4.12 Standby power selection switch X

2.14 Code data plate X 5 PIT

2.30 Hydraulic power unit X 5.1 Pit access, lighting, stop switch & condition X

2.31 Relief valves X 5.2 Bottom clearance, runby & minimum refuge space X

2.32 Control valve X 5.4 Normal terminal stopping devices X

2.33 Tanks X 5.5 Traveling cables X

2.36 Hydraulic cylinders X 5.6 Governor-rope tension devices X

2.37 Pressure switch X 5.7 Car frame and platform X

2.38 Roped water hydraulic elevators X 5.8 Car and counterweight safeties and guiding members X

2.39 Low oil protection X 5.11 Buffers and emergency terminal speed-limiting devices X

2.40 Maintenance records X 5.12 Car buffers X

2.41 Static control X 5.13 Building members X

2.42 Earthquake inspection and tests (seismic risk zone 2 or greater) X 5.14 Supply Piping X

2.44 Auxillary power lowering operation X 5.15 Overspeed valve X

2.45 Inspection operation with open door circuits and inspection hierarchy X 5.16 Earthquake inspection and tests (seismic risk zone 2 or greater) X

5.17 Plunger gripper X

3 TOP OF CAR 6 FIREFIGHTERS' SERVICE (FEO)

3.1 Top-of-car stop switch X 6.1 A17.1b-1973 through A17.1b-1980 X

3.2 Car top light and outlet X 6.2 17.1-1981 through A17.1b-1983 X

3.3 Top-of-car operating device X 6.3 A17.1-1984 through A17.1a-1988 and A17.3 X

3.4 Top-of-car clearance, refuge space, and standard railing X 6.4 A17.1b-1989 through A17.1d-2000 X

3.5 Normal terminal stopping devices X 6.5 A 17.1-2000/644-00 X

3.6 Final and emergency terminal stopping devices X 6.6 A 17.1-2004/644-04 X

3.7 Car leveling and anticreep devices X 6.7 A17.1-2007/B44-07 X

IWO372171 | H0266 #RID#IN365191

Agency Address:

Maintenance Company Information:

Maintenance Company:

Oracle Elevator : Oracle Elevator - Shreveport

Building Information:

Location Address:

Sylvan Friedman Student Union 185 Sam Sibley DR Natchitoches, LA 71457

Location ID:

735003-30

Location Contact Information:

Name: Thad Warren Title:

Phone: +13183574402 Email: warrent@nsula.edu

Inspection Information:

Inspection Date: 8/19/2024 Inspection Start Time: 1:30:00 PM Inspection End Time: 2:00:00 PM

Inspector: Voiles, Jeff || Inspection Type: Routine/Periodic Inspection Result: Passed - Violations

Re-Inspection Required: No Generator Test Performed: No Re-Inspection Maint Co Required: No

Device ID: H0266 Device Type: Hydraulic Elevator # of Landings: 2

Due Month: February Device Use: Passenger Device Designation: # 1

Code Edition: Installation Date: 2/6/2000 Device Manufacturer: Schindler

Overspeed Valve? Plunger Gripper? Cat 5 Required?

Capacity: 2100 Speed: 100

Inspector Notes:

Testing Results:

Violation Information:

Previous Violations Previous Violation Inspector Comments Corrected?

2.5 Housekeeping A17.1- 4.8.2.6 Remove all non-related elevator materials from elevator machine room No

5.1 Pit access; lighting; stop switch; and condition 8.6.4.7 Clean elevator pit No

IWO372171 | H0266 #RID#IN365191

ID No: H0266 Device Type: Hydraulic Elevator Date: 8/19/2024 Inspection Type: Routine/Periodic

Firm #: 33 Code Edition: Location Contact Name: Thad Warren

Inspected By: Voiles, Jeff || Signature: Location Contact Signature:

Notes: See ASME A17.2 for detailed Code requirements. Numbering is tied to the numbering of A 17.2 Items. OK= meets requirements; NG= doesn't meet requirements; N/A = not applicable.

1 INSIDE OF CAR OK NG N/A OK NG N/A

1.1 Door reopening device X 3.9 Floor and emergency identification numbering X

1.2 Stop Switches X 3.10 Hoistway Construction X

1.3 Operating control devices X 3.11 Hoistway smoke control X

1.4 Sills and car floor X 3.12 Pipes, wiring, and ducts X

1.5 Car lighting and receptacles X 3.13 Windows, projections, recesses, and setbacks X

1.6 Car emergency signal X 3.14 Hoistway clearances X

1.7 Car door or gate X 3.15 Multiple hoistways X

1.8 Door closing force X 3.16 Traveling cables and junction boxes X

1.9 Power closing of doors or gates X 3.17 Door and gate equipment X

1.10 Power opening of doors or gates X 3.18 Car frame and stiles X

1.11 Car vision panels and glass car doors X 3.19 Guide rails, fastenings, and equipment X

1.12 Car enclosure X 3.20 Governor rope X

1.13 Emergency exit X 3.21 Governor releasing carrier X

1.14 Ventilation X 3.22 Wire rope fastening and hitch plate X

1.15 Signs and operating device symbols X 3.23 Suspension compensation and governor systems X

1.16 Rated load, platform area, and data plate X 3.27 Crosshead data plate and rope data tags X

1.17 Standby power operation X 3.28 Counterweight and counterweight buffer X

1.18 Restricted opening of car or hoistway doors X 3.29 Counterweight safeties X

1.19 Car ride X 3.30 Speed Test X

1.20 Earthquake inspection and tests (seismic risk zone 2 or greater) X 3.31 Slack rope test - roped hydraulic elevators X 2 MACHINE ROOM 3.32 Traveling sheave-roped-hydraulic elevators installed under A17.1B-1989 and later editionsX

2.1 Access to machinery space X 3.34 Earthquake inspection and tests (seismic risk zone 2 or greater) X

2.2 Headroom X 4 OUTSIDE HOISTWAY

2.3 Lighting and receptacles X 4.1 Car platform guard X

2.4 Machinery space X 4.2 Hoistway doors X

2.5 Housekeeping X 4.3 Vision panels X

2.6 Ventilation X 4.4 Hoistway door-locking devices X

2.7 Fire extinguisher X 4.5 Access to hoistway X

2.8 Pipes, wiring, and ducts X 4.6 Power closing of hoistway doors X

2.9 Guarding of exposed auxiliary equipment X 4.7 Sequence operation X

2.10 Numbering of elevators, machines, controllers & disconnect switches X 4.8 Hoistway enclosure X

2.11 Disconnecting means and control X 4.9 Elevator parking devices X

2.12 Controller wiring, fuses, grounding, etc. X 4.10 Emergency doors in blind hoistways X

2.13 Governor, overspeed switch, and seal X 4.12 Standby power selection switch X

2.14 Code data plate X 5 PIT

2.30 Hydraulic power unit X 5.1 Pit access, lighting, stop switch & condition X

2.31 Relief valves X 5.2 Bottom clearance, runby & minimum refuge space X

2.32 Control valve X 5.4 Normal terminal stopping devices X

2.33 Tanks X 5.5 Traveling cables X

2.36 Hydraulic cylinders X 5.6 Governor-rope tension devices X

2.37 Pressure switch X 5.7 Car frame and platform X

2.38 Roped water hydraulic elevators X 5.8 Car and counterweight safeties and guiding members X

2.39 Low oil protection X 5.11 Buffers and emergency terminal speed-limiting devices X

2.40 Maintenance records X 5.12 Car buffers X

2.41 Static control X 5.13 Building members X

2.42 Earthquake inspection and tests (seismic risk zone 2 or greater) X 5.14 Supply Piping X

2.44 Auxillary power lowering operation X 5.15 Overspeed valve X

2.45 Inspection operation with open door circuits and inspection hierarchy X 5.16 Earthquake inspection and tests (seismic risk zone 2 or greater) X

5.17 Plunger gripper X

3 TOP OF CAR 6 FIREFIGHTERS' SERVICE (FEO)

3.1 Top-of-car stop switch X 6.1 A17.1b-1973 through A17.1b-1980 X

3.2 Car top light and outlet X 6.2 17.1-1981 through A17.1b-1983 X

3.3 Top-of-car operating device X 6.3 A17.1-1984 through A17.1a-1988 and A17.3 X

3.4 Top-of-car clearance, refuge space, and standard railing X 6.4 A17.1b-1989 through A17.1d-2000 X

3.5 Normal terminal stopping devices X 6.5 A 17.1-2000/644-00 X

3.6 Final and emergency terminal stopping devices X 6.6 A 17.1-2004/644-04 X

3.7 Car leveling and anticreep devices X 6.7 A17.1-2007/B44-07 X

IWO372171 | H0267 #RID#IN365191

Agency Address:

Maintenance Company Information:

Maintenance Company:

Oracle Elevator : Oracle Elevator - Shreveport

Building Information:

Location Address:

A.A. Fredericks Fine Arts Center 150 Central Ave Natchitoches, LA 71457

Location ID:

735003-12

Location Contact Information:

Name: Thad Warren Title:

Phone: +13183574402 Email: warrent@nsula.edu

Inspection Information:

Inspection Date: 8/20/2024 Inspection Start Time: 8:00:00 AM Inspection End Time: 8:30:00 AM

Inspector: Voiles, Jeff || Inspection Type: Routine/Periodic Inspection Result: Passed - Violations

Re-Inspection Required: No Generator Test Performed: No Re-Inspection Maint Co Required: No

Device ID: H0267 Device Type: Hydraulic Elevator # of Landings: 3

Due Month: February Device Use: Passenger Device Designation: #1 Passenger

Code Edition: 1980 - A17.1b Installation Date: 4/8/1981 Device Manufacturer: Dover

Overspeed Valve? Plunger Gripper? Cat 5 Required?

Capacity: 2500 Speed: 125

Inspector Notes:

Testing Results:

Violation Information:

New Violations Violation Inspector Comments

1.18 Restricted opening of car or hoistway doors 9.2.5.3- repair elevator car door restrictor, not operating properly

5.1 Pit access; lighting; stop switch; and condition 1.3.9.5- repair elevator pit lighting Previous Violations Previous Violation Inspector Comments Corrected?

3.17 Door and gate equipment NEC- 620.4 - Provide electrical covers for missing hoist way door interlocks No

5.1 Pit access; lighting; stop switch; and condition A17.1- 8.6.4.7 Clean the elevator pit area No

2.5 Housekeeping 8.6.4.8 Clean elevator machine room No

IWO372171 | H0267 #RID#IN365191

ID No: H0267 Device Type: Hydraulic Elevator Date: 8/20/2024 Inspection Type: Routine/Periodic

Firm #: 33 Code Edition: 1980 - A17.1b Location Contact Name: Thad Warren

Inspected By: Voiles, Jeff || Signature: Location Contact Signature:

Notes: See ASME A17.2 for detailed Code requirements. Numbering is tied to the numbering of A 17.2 Items. OK= meets requirements; NG= doesn't meet requirements; N/A = not applicable.

1 INSIDE OF CAR OK NG N/A OK NG N/A

1.1 Door reopening device X 3.9 Floor and emergency identification numbering X

1.2 Stop Switches X 3.10 Hoistway Construction X

1.3 Operating control devices X 3.11 Hoistway smoke control X

1.4 Sills and car floor X 3.12 Pipes, wiring, and ducts X

1.5 Car lighting and receptacles X 3.13 Windows, projections, recesses, and setbacks X

1.6 Car emergency signal X 3.14 Hoistway clearances X

1.7 Car door or gate X 3.15 Multiple hoistways X

1.8 Door closing force X 3.16 Traveling cables and junction boxes X

1.9 Power closing of doors or gates X 3.17 Door and gate equipment X

1.10 Power opening of doors or gates X 3.18 Car frame and stiles X

1.11 Car vision panels and glass car doors X 3.19 Guide rails, fastenings, and equipment X

1.12 Car enclosure X 3.20 Governor rope X

1.13 Emergency exit X 3.21 Governor releasing carrier X

1.14 Ventilation X 3.22 Wire rope fastening and hitch plate X

1.15 Signs and operating device symbols X 3.23 Suspension compensation…