5 Plans.pdf

PDF 8 MB Posted

Attached to
26-18 Sto842436B (Story)
Solicitation number
26-18 Sto842436B (Story)
Issued by
Taylor County, Iowa

About this file

This file contains five architectural and engineering plans for a state or local infrastructure project. The plans include site plans, floor plans, elevation drawings, and utility layouts that appear to support a construction or renovation project. The document provides detailed specifications for spatial configurations, building dimensions, material designations, and site improvements. The plans establish the baseline design requirements and technical specifications that bidders must reference when preparing proposals and cost estimates. While specific response dates, bid due dates, site visit schedules, and bidders' meetings are not detailed within the plans themselves, these drawings serve as essential contract documents that define the scope of work and project deliverables.

The plans do not contain explicit pricing terms, set-asides, incumbent information, funding sources, or contract duration details. As technical specification documents, the plans function as reference materials to be incorporated into the broader solicitation package alongside separate procurement documents, budget information, and contractual terms. Bidders should cross-reference these plans with the main solicitation notice and any associated amendments or addenda for complete information regarding pricing, evaluation criteria, contract period, and other material terms.

View the file

Other files

File Type Posted
2 BID BOOK.pdf PDF
6 Design Report.pdf PDF
9 Bid Bond.pdf PDF
8 Proposal - Acknowledgement - Affidavit.pdf PDF
3 Bid Book.pdf PDF
1 Notice to Bidders.pdf PDF
7 Schedule of Prices.pdf PDF
4 Specifications.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T AVE

SW

RD

S

T

TH

S T

0T

H A

V E

0T

H A

V E

0T

H A

V E

0T

H A

V E

210TH ST

X AVE

272ND ST

250TH ST

0T

H A

V E

5T

H A

V E

5T

H A

V E

0T

H A

V E

0T

H A

V E

240TH ST

0T

H A

V E

0T

H A

V

E260TH ST

0T

H A

V E

270TH ST

200TH ST

563RD

A

V E

200TH ST

170TH ST

0T

H A

V E

A

RR

A

SM

ITH

T

RA

IL

G

RA

N T

A V

E

RIVERSIDE RD

215TH ST

280TH ST

LINCOLN HWY

TH

S T

260TH ST

270TH ST

0T

H A

V E

220TH ST

LINCOLN HWY

0T

H A

V

E LINCOLN HWY

260TH ST

260TH ST

0T

H A

V E

0T

H A

V E

0T

H A

V E

170TH ST

0T

H A

V E

190TH ST

0T

H A

V E

170TH ST 170TH ST

0T

H A

V E

0T

H A

V E

190TH ST

190TH ST

0T

H A

V E

210TH ST

0T

H A

V E

170TH ST

0T

H A

V E

280TH ST280TH ST

C O

UN

TR

Y C

LU

B

RD

250TH ST

220TH ST

6T

H A

V E

0T

H A

V E

0T

H A

V E

0T

H A

V E

W MAPLE AVE

SA

N

D H

ILL

T

R

245TH ST

250TH ST

270TH ST

270TH ST

0T

H A

V E

265TH ST

TIM

BE

R

RD

0T

H A

V E

180TH ST

0T

H A

V E

210TH ST

5T

H A

V E

0T

H A

V E 59

0T H

A V

E

0T

H A

V

E180TH ST

N . D

A

YT

O N

A V

E

0T

H A

V E

200TH ST

0T

H A

V E

0T

H A

V E

210TH ST

160TH ST

0T

H A

V E

0T

H A

V E

G

RA

N T

A V

E

180TH ST180TH ST

190TH ST

G

EO

RG

E

W

C A

RV

ER

A V

E

T AVE

175TH ST

N O

RT

H

D A

KO

TA

A V

E

ZUMWALT

STATION RD

SOUTH

S AVE

280TH

ST

G

EO

RG

E

W

C A

RV

ER

A V

E

220TH ST

2N

D A

V E

ONTARIO ST

9T

H

AV

E

STA

G

EC

O

A C

H RD

RI

V

ER

SI

D E

D R

DARTMOOR RD

C

ED

A R

LN

0T

H A

VE

180TH ST

190TH ST

5T

H A

V E

N . D

A

YT

O N

A V

E

7T

H A

V E

SO

UT

H D

A

KO

TA

A

V E

275TH

ST

GILBERT

AMES

NEVADA

KELLEY

Onion

Cr ee k

S q ua w

C reek

Sk un k

R iv er

C re ek

G ra nt

O pen

Ditch

In d ia n

W est

W alnut

S kunk

Cre ekW or le

NAT'L

ANIMAL

DISEASE

CENTER

I.S.U.

HORT.

FARM

IOWA

STATE

UNIVERSITY

SHIPLEY

SOPER'S

MILL

ACCESS

McFARLAND

PARK

PETERSON

PARK R I C H L A N D

M I L F O R D

F R A N K L I N

W A S H I N G T O N

G R A N T

N E V A D A

23456

7 8 9 11

131415161718

19 20 21 23 24

31 32 36

23456

7 8 9 11 12

131415161718

19 20 22 23 24

2627282930

32 33 34 35 36

7 8

19 20

131718

19 21 22 23

252627282930

33 34 35 36

7 8 9 11

131415161718

19 20 21 23 24

252627282930

31 32 33 34 35 36

19 20

31 32

STATE

NURSERY

E23 E23

E57

R63 R50

E26

R38

R63

E29 R77

E41

S14

E29

R38

E57

R70

S14

CAMERON SCHOOL RD

AMES

MUNICIPAL

AIRPORT S

D A

YT

O

N A

V E

R50

OLD BLOOMINGTON RD

W

RD

S

T

‒‒119

‒‒118

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

A0

1.

dw g 9/

/2

8:

:0

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

A.01

TITLE SHEET

PROJECT DATUM: STATE PLANE

HORIZONTAL: IOWA NORTH

VERTICAL: NAVD 1988

MY LICENSE RENEWAL DATE IS

PAGES OR SHEETS COVERED BY THIS SEAL:

LICENSE NUMBER: DATE:

I OWA

LI

CE

NS

ED

PROFESS IONAL ENG

INEER

I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS

PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION

AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER

UNDER THE LAWS OF THE STATE OF IOWA.

29449

12/31/2026

ALL SHEETS

BRANDON C.

SHORT

29449

BRANDON C. SHORT, PE

STORY COUNTY, IA

CONSTRUCTION PLANS FOR

IDALS NO. STO842436B

NUTRIENT REDUCTION WETLAND

STORY COUNTY, IOWA

SEPTEMBER 2026

THE SPECIFICATIONS AS PREPARED BY IOWA DEPARTMENT OF AGRICULTURE

AND LAND STEWARDSHIP AND BOLTON & MENK, INC. SHALL BE CONSIDERED

AS PART OF THIS DOCUMENT. NATURAL RESOURCES CONSERVATION SERVICE

CONSTRUCTION SPECIFICATIONS SHALL APPLY.

THE CURRENT EDITION OF THE "IOWA STATEWIDE URBAN STANDARD

SPECIFICATIONS FOR PUBLIC IMPROVEMENTS" SHALL GOVERN.

IOWA DEPARTMENT OF TRANSPORTATION "STANDARD SPECIFICATIONS FOR

HIGHWAY AND BRIDGE CONSTRUCTION" AND ALL CURRENT GENERAL

SUPPLEMENTAL SPECIFICATIONS AND MATERIALS INSTRUCTIONAL

MEMORANDUM SHALL GOVERN AS REFERENCED.

ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS AND ORDINANCES WILL BE

COMPLIED WITH IN THE CONSTRUCTION OF THIS PROJECT.

GOVERNING SPECIFICATIONS

THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS UTILITY QUALITY

LEVEL D. THIS UTILITY QUALITY LEVEL WAS DETERMINED ACCORDING TO

THE GUIDELINES OF CI/ASCE 38-02, ENTITLED "STANDARD GUIDELINES FOR

THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA."

THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING IOWA ONE CALL BY

PHONE AT 811, OR ON THE WEB AT

HTTP://WWW.IOWAONECALL.COM/. THIS IS REQUIRED BY LAW.

TICKET# ___________.

TICKET NUMBER MUST BE PROVIDED TO THE ENGINEER AND IDALS PRIOR

TO COMMENCEMENT OF WORK.

NRCS, IDALS, and the engineer make no representation as to the existence or nonexistence of any utility, public and/or private, buried or overhead, except as shown on the drawings. Where utilities are shown on the drawings, the location, depth and/or height are approximate. The exact location, depth and/or height must be determined by the utility company and/or the land owner prior to any construction within the project vicinity.

NOTES

1. IF A CULTURAL RESOURCE IS IDENTIFIED DURING

CONSTRUCTION, STOP WORK IMMEDIATELY AND NOTIFY

THE LOCAL NATURAL RESOURCES CONSERVATION SERVICE

OFFICE.

2. THERE IS NO GUARANTEE THAT THE WETLAND WILL FILL OR

REMAIN FILLED WITH WATER.

R-24W

PROJECT

LOCATION

T-

N

CONSERVATION PRACTICE STANDARDS USED:

656 - CONSTRUCTED WETLAND

NRCS JOB CLASS: IV

300 AC < WATERSHED AREA < 1000 AC

TO THE BEST OF MY PROFESSIONAL KNOWLEDGE,

JUDGEMENT, AND BELIEF, THESE PLANS MEET APPLICABLE

NRCS STANDARDS AND APPLICABLE LAWS AND

REGULATIONS.

R

FEETSCALE

0 1 2

SHEET INDEX

SHEET NO. SHEET TITLE

A.01 TITLE SHEET

A.02 PLAN OVERVIEW

A.03 SITE OVERVIEW

A.04 EXISTING CONDITIONS & REMOVALS

B.01 INLET STRUCTURE DETAIL

B.02 OUTLET STRUCTURE DETAIL

B.03 TRASH GUARD DETAIL

B.04 PUMP BASIN & SOLAR ARRAY DETAILS

B.05 RCP INSTALLATION DETAIL

B.06 CPDT INSTALLATION DETAIL

C.01 ESTIMATED QUANTITIES

D.01 GRADING OVERVIEW

K.01 SEEDING OVERVIEW

M.01 PLAN & PROFILE - PUMP INLET PIPE & OUTLET PIPE

M.02 PLAN & PROFILE - DITCH INLET PIPE

M.03 PLAN & PROFILE - TILE RE-LAY

M.04 PLAN & PROFILE - RING TILE

T-

N

R-23W R-22W

T-

N T-

N

R-24W R-23W R-22W brandon.short Text Box 9/16/2026 l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l

900900

CITY OF AMES

CITY OF AMES

CITY OF AMES

KEPLEY, DANNY LEE

& SUSAN LYNN

KEPLEY, DANNY LEE

& SUSAN LYNN

KEPLEY, DANNY LEE

& SUSAN LYNN

MILLEMAN PRAIRIE

FARMS LLC

OLSON, BERNARD DEAN

INLET STRUCTURE

MODIFIED SW-513

DITCH INLET PIPE

12" RCP

30 FT INLET CHANNEL

EXCAVATE POOL TO 891.25

SOLAR-POWERED PUMP BASIN

PUMP INLET PIPE

15" RCP

SW-401

DD 39 TILE RE-LAY

18" DUAL-WALL HDPE

SW-401

EXISTING DD 39 18" TILE

JET TO DOWNSTREAM INTAKE

OUTLET PIPE

18" RCPOUTLET STRUCTURE

MODIFIED SW-513

NWL = 892.25

CONSTRUCTION ACCESS

EXISTING DD 39 16" TILE

PROPERTY LINES

PROPOSED EASEMENT BOUNDARY

SOLAR PANEL LOCATION

INSTALL ABOVE 898.50

CITY OF AMES EXISTING WATER MAIN

RING TILE

6" HDPE

4 FT WIDE COVER BERM

100-YEAR HWL = 893.82

SEDIMENT FOREBAY

DIVERSION BERM

DIVERSION BERM

NORMAL POOL (892.25)

100-YEAR HWL (893.82)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 891.25

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

A0

2.

dw g 9/

/2

8:

:3

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

A.02

PLAN OVERVIEW

R

FEETSCALE

0 60 120

HORZ.

DESIGN CRITERIA VALUE UNIT REQUIREMENT

PUMPED WATERSHED AREA 354.1 ACRES

PUMP PEAK FLOW 0.98 CFS

PUMP PERCENT CAPTURE 48.7 %

EFFECTIVE TREATED PUMPED WATERSHED 172.0 ACRES

DITCH WATERSHED AREA 661.5 ACRES

DITCH PERCENT CAPTURE 92.7 %

EFFECTIVE TREATED DITCH WATERSHED 613.0 ACRES

TOTAL EFFECTIVE TREATED WATERSHED AREA 785.0 ACRES

SURFACE WATERSHED AREA 382.6 ACRES

POOL NORMAL WATER LEVEL (NWL) ELEV 892.25 FT

DESIGNED WETLAND POOL AREA (@ NWL) 4.9 ACRES

PERCENT POOL AREA TO WATERSHED AREA 0.6 % Range 0.5% to 2% of watershed area

MAXIMUM POOL DEPTH 1.75 FT

AVERAGE POOL DEPTH 1.0 FT

DEEP WATER AREA (DEPTH > 3 FT) 0.0 ACRES

PERCENT DEEP WATER TO POOL AREA 0.0 % Less than 25%

POOL STORAGE VOLUME AT NWL 4.8 ACRE-FT

OVERFLOW ELEVATION 893.07 FT Natural Overflow

POOL STORAGE VOLUME AT OVERFLOW 10.7 ACRE-FT

PRIMARY WEIR ELEVATION 892.25 FT Conveys Tile Flow Only PRIMARY WEIR WIDTH 16 FT Modified SUDAS SW-513 Outlet Structure

TOTAL EASEMENT AREA 31.8 ACRES

AREA OF BUFFER 26.9 ACRES

RATIO BUFFER AREA TO NWL POOL AREA 5.4

25-YEAR STORM HWL IN POOL 893.69 FT

25-YEAR PEAK INFLOW 359 CFS

25-YEAR PEAK OUTFLOW 338 CFS

100-YEAR STORM HWL IN POOL 893.82 FT

100-YEAR PEAK INFLOW 515 CFS

100-YEAR PEAK OUTFLOW 496 CFS

WETLAND ELEV INCREMENTAL CUMULATIVE CUMULATIVE

POOL DEPTH AREA VOLUME VOLUME

(FT) (FT) (FT2

) (FT3

) (AC-FT)

0.0 891.25 203,400

0.8 892.00 212,400 155,925 3.58

1.0 892.25 215,500 209,413 4.81

1.8 893.00 391,026 436,860 10.03

1.8 893.07 434,251 465,744 10.69

2.0 893.25 577,078 556,764 12.78

2.3 893.50 758,252 723,680 16.61

© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l

KEPLEY, DANNY & SUSAN

KEPLEY, DANNY & SUSANCITY OF AMES

CITY OF AMES

CITY OF AMES

KEPLEY, DANNY & SUSAN

CITY OF AMES

KEPLEY, DANNY & SUSAN

HADE, DAVID &

DELORA JESPERSEN

POUNDS, SIDNEY C

& DIANA J

KEPLEY, DANNY & SUSAN

OLSON, BERNARD DEAN

ROCHE, ALLEN D

OLSON, BERNARD DEAN

MILLEMAN PRAIRIE

FARMS LLC

904 90

PROPOSED EASEMENT BOUNDARY

CONSTRUCTION ACCESS FROM STAGECOACH ROAD

PROPERTY LINES

SPOIL AREA EXTENTS

STAGECOACH ROAD

EXISTING CITY OF

AMES WATER MAIN

FEMA REGULATORY FLOODWAY BOUNDARY

FEMA NFHL 1% ANNUAL CHANCE FLOOD HAZARD

FEMA NFHL 0.2% ANNUAL CHANCE FLOOD HAZARD

NATURAL OVERFLOW 893.07

EXISTING TILE INTAKE

W

ATER JET EXISTING TILE M

AIN 526 LF

NORMAL POOL (892.25)

100-YEAR HWL (893.82)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 891.25

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

A0

3.

dw g 9/

/2

8:

:3

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

A.03

SITE OVERVIEW

R

FEETSCALE

0 100 200

HORZ.

l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l

PRESERVE EXISTING UTILITY POLE

PRESERVE EXISTING CITY

OF AMES WATER MAIN

COMPLETELY REMOVE EXISTING TILE FOR 50 FT

REMOVE EXISTING TILE

MIN. 5 FT REMOVED EVERY 50 FT

MAY CRUSH IN PLACE IF CLAY

893894

894894

898898

896896

895895895

89389389

896896896897

896896

894894

EXISTING DD 39 16" TILE

EXISTING DD 39 18" TILE

KEPLEY, DANNY & SUSAN

KEPLEY, DANNY & SUSAN

CITY OF AMES CITY OF AMES

CITY OF AMES

KEPLEY, DANNY

& SUSAN

MILLEMAN PRAIRIE

FARMS LLC

OLSON, BERNARD DEAN

COMPLETELY REMOVE EXISTING TILE FOR 50 FT

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

A0

4.

dw g 9/

/2

8:

:1

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

A.04

EXISTING CONDITIONS & REMOVALS

R

FEETSCALE

0 50 100

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

B0

1.

dw g 9/

/2

8:

:2

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.01

INLET STRUCTURE DETAIL

SEE SUDAS FOR SW-513 DETAILS.

PRECAST STRUCTURE SHALL BE ONE

SECTION OR PROVIDE WATERTIGHT SEAL

BETWEEN SECTIONS.

TOP OF STRUCTURE ELEVATION (SEE PROFILE)

PRECAST OPENING ELEVATION

OPENING THIS SIDE

B.03

" W

AL

L

W

ID

TH

48" WALL WIDTH

6" SUMP

FL ELEV (SEE PROFILE)

SEE SUDAS FOR SW-513 DETAILS

SEE M.02 FOR RIP RAP PLACEMENT

BEDDING PER SUDAS

48" WALL WIDTH

MANHOLE LID

SECTION

MODIFIED SW-513

INLET STRUCTURE

PLAN

MODIFIED SW-513

INLET STRUCTURE

NOT TO SCALENOT TO SCALE

2 LF 12" SCH 40 PVC

12" VALTERRA KNIFE VALVE

OR APPROVED EQUAL

1 LF 12" SCH 40 PVC

WITH FLEXIBLE COUPLER

2 LF 12" SCH 40 PVC

12" VALTERRA KNIFE VALVE

OR APPROVED EQUAL

1 LF 12" SCH 40 PVC

WITH FLEXIBLE COUPLER

12" RCP

12" RCP

VALVE HANDLE WITH EXTENSIONS

PROVIDE 4" OR LARGER SCH 40 PVC

AROUND HANDLE AND EXTENSIONS

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

B0

1.

dw g 9/

/2

8:

:2

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.02

OUTLET STRUCTURE DETAIL

TOP OF STRUCTURE ELEVATION (SEE PROFILE)

A B.01

A

6" SUMP

FL ELEV (SEE PROFILE)

PRECAST OPENING ELEVATION

PROVIDE FLEXIBLE, WATERTIGHT GASKET FOR PIPE OPENINGS

SEE SUDAS FOR SW-513 DETAILS

PRECAST STRUCTURE SHALL BE ONE SECTION OR

PROVIDE WATERTIGHT SEAL BETWEEN SECTIONS.

78" WALL

WIDTH

78" WALL WIDTH

1.25'

SEE SUDAS FOR SW-513 DETAILS

OUTLET PIPE

BEDDING PER SUDAS

78" WALL WIDTH

2 LF 12" DUAL-WALL HDPE

12" HICKENBOTTOM INTAKE

OR APPROVED EQUAL

2 LF 12" DUAL-WALL HDPE

12" HICKENBOTTOM INTAKE OR APPROVED EQUAL

12" 90° ELBOW

EXCAVATED WETLAND POOL

EXCAVATE 1 FT ADDITIONAL AROUND INTAKE

PLACE RIP RAP IN 3-FT DIA. CIRCLE AROUND INTAKE

UNDERLAY WITH GEOTEXTILE (1.5 TN)

PLACE RIP RAP IN 6-FT DIA. CIRCLE AROUND INTAKE

UNDERLAY WITH GEOTEXTILE (1.5 TN)

AGRI DRAIN IN-LINE

WATER LEVEL CONTROL

STRUCTURE OR

APPROVED EQUAL

ATTACH TO CONCRETE

STRUCTURE

AGRI DRAIN IN-LINE WATER LEVEL CONTROL

STRUCTURE OR APPROVED EQUAL

STUB IN 12" PIPE

BACKFILL MIN. 1 FT AROUND

WCS WITH 1" CLEAN ROCK

NORMAL WATER LEVEL

9" INLET OPENING

ON ALL SIDES

6" x 6" CENTER

PIER ON ALL

SIDES

STRUCTURE LID PER SUDAS

FIT WITH SW-604 TYPE 5 CASTING

3 FT

SECTION

MODIFIED SW-513

OUTLET STRUCTURE

PLAN

MODIFIED SW-513

OUTLET STRUCTURE

NOT TO SCALE

NOT TO SCALE

NOTES:

1. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS

STEEL.

2. HICKENBOTTOM INTAKE, WATER LEVEL CONTROL

STRUCTURE, DUAL-WALL HDPE, ELBOW, TRASH GUARD,

CASTING, AND ALL HARDWARE AND APPURTENANCES

SHOWN ON THIS PAGE OR REQUIRED FOR INSTALLATION

ARE SUBSIDIARY TO THE OUTLET STRUCTURE.

18" RCP OUTLET PIPE

OPENINGS FOUR

SIDES WITH

CENTER PIERS

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

B0

1.

dw g 9/

/2

8:

:2

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.03

TRASH GUARD DETAIL

TRASH GUARD FOR WETLAND OUTLET STRUCTURE

48"

SHEET STEEL

SHEET STEEL

SHEET STEEL

90"

GROUND CONTACT

TREATED POST 4"x4"

OUTLET

STRUCTURE

12" MIN

SPACE

BELOW

GUARD

24"

CONCRETE FOOTINGS

MIN 12" DIAMETER

4 FT MIN.

EMBEDMENT

NOTE: TRASH GUARD AND APPURTENANCES ARE TYPICAL FOR ALL SIDES OF OUTLET STRUCTURE. QUANTITIES

AND DIMENSIONS FOR STEEL SHEETS PER SIDE OF STRUCTURE ARE AS FOLLOWS:

1 - STEEL SHEET - 90" x 24" x 3/8" 2 - STEEL SHEETS - 48" x 24" x 3/8"

ANGLE IRON--EITHER WELDED OR BOLTED--ON TOP AND BOTTOM OF EACH SHEET AS BRACE.

BOLT TRASH GUARD ONTO ANGLE IRON ANCHORED TO OUTLET STRUCTURE.

PROVIDE THREE POSTS WITH CONCRETE FOOTINGS ON EACH SIDE

GRADE AS NECESSARY TO ALLOW FLOW OF WATER UNDER TRASH GUARD WITH 12" MINIMUM CLEARANCE.

ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL

NOT TO SCALE

STRUCTURE

OPENING

SEE CONNECTION TO

STRUCTURE DETAIL

GRADE BELOW TRASH GUARD TO

PROVIDE 12" MINIMUM SPACE

BETWEEN BOTTOM OF STEEL AND

TOP OF RIP RAP (TYP. ALL SIDES)

CONCRETE STRUCTURE

SHEET STEEL

4" x 4" x 3/8" ANGLE

3/8" BOLT WITH CONCRETE ANCHOR

BOLTS SHALL BE PLACED IN THE CENTER OF THE WALL (TYP)

TRASH GUARD CONNECTION TO STRUCTURE

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

B0

1.

dw g 9/

/2

8:

:3

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.04

PUMP BASIN & SOLAR ARRAY DETAILS

3.5' 21' 3.5'

Included in kit Included in kit

10.5'

17'

4.5' to 5'

DPC2500

solar drive

Solar + -

Solar disconnect

SOLAR ARRAY SUPPORT INSTALLATION DETAILS

NOTE:SOLAR PANELS SHALL BE INSTALLED IN THE LOCATION SHOWN ON A.03 AND

M.02 WITH A SOUTHWARD ORIENTATION.

SOLAR POWERED PUMP SYSTEM (BID ITEM 18) SHALL INCLUDE THE FOLLOWING:

· SOLAR PANELS

· SOLAR DRIVE

· 3-PHASE, 3 HP AXIAL PUMP (CARRY CP-04 WITH 20° IMPELLER OR APPROVED EQUAL,

PROVIDING 390 GPM AT 12.5 FT TDH)

· FLOAT SWITCH

· MOUNTING CLAMPS FOR CONTROLLER

· SOLAR PANEL MOUNTING KIT

· STEEL PIPE EXTENDERS

· WIRED GENERATOR PLUG

· LIGHTNING & SURGE PROTECTOR

· WIRING FOR PANELS, PUMP, AND CONTROLLER

CONTRACTOR SHALL PROVIDE THE FOLLOWING, SUBSIDIARY TO BID ITEM 20:

· STEEL PIPE FOR MOUNTING

· CONCRETE AND ROCK BEDDING FOR MOUNTING POLES

· PVC DISCHARGE PIPE

· CHECK VALVE

PUMP BASIN (BID ITEM 17) SHALL INCLUDE THE FOLLOWING:

· PUMP BASIN (MODIFIED SW-401, SEE DETAILS)

· STEEL LID WITH STAND

MOUNT PUMP CONTROLLER TO

SOLAR POSTS ABOVE 898.50

SOLAR ARRAY SUPPORT

INSTALLATION DETAILS

NOT TO SCALE

PUMP WIRING DIAGRAM

NOT TO SCALE

15 FT

8 FT

PUMP CONTROLLER AND

SOLAR PANELS SHALL BE

ENTIRELY ABOVE THE

ELEVATION 898.50

60 FT

INSTALL SOLAR DRIVES NEXT TO PUMPS

ON POSTS ABOVE 898.50

PLACE 6" CLEAN 1" ROCK IN BOTTOM OF HOLE

FILL HOLE WITH CONCRETE

MIN. 12" DIAMETER

FLOW

NOT TO SCALE

SW-401 WEIR & PUMP BASIN ELEVATION

EXTERIOR MASTIC &

FABRIC WRAP

ALL JOINTS - 9" WIDE

4'

14'

MIN. 12"

15" RCP

FL EL = 886.15

PAINTED STEEL LID WITH ACCESS HATCH

TOP EL = 895.50

8" PVC PUMP OUTLET

EL = 893.50

EXISTING GROUND

APPROX. EL = 893

NORMAL POOL = 892.25

8" MIN. CLASS I BEDDING MATERIAL

SUMP = 879.50

SUDAS SW-401 STRUCTURE

2 FT

PLACE RIP RAP

SEE M.02

FLOAT ELEVATION

ON OFF

886.20 881.50

INSTALL PUMP CONTROL PANELS

ADJACENT TO PUMP BASIN. MOUNT

ON POSTS ABOVE ELEVATION 896.50.

INSTALL CHECK VALVE

FLEXIBLE WATERTIGHT SEAL

4'

14'

15" RCP

FL EL = 886.15

PAINTED STEEL LID WITH ACCESS HATCH

TOP EL = 895.50

8" PVC PUMP OUTLET

EL = 893.50

8" MIN. CLASS I BEDDING MATERIAL

SUMP = 879.50

SUDAS SW-401 STRUCTURE

FLEXIBLE WATERTIGHT SEALS

NOT TO SCALE

SW-401 WEIR & PUMP BASIN SECTION

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

B0

1.

dw g 9/

/2

8:

:3

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.05

RCP INSTALLATION DETAIL

TRENCH INSTALLATION TYPE 3

COMPLETELY FILL

HAUNCH AREA WITH

GRAVELLY SAND

COMPACT TO 85%

STANDARD PROCTOR

DENSITY.

Do

LOOSELY PLACED UNCOMPACTED

GRAVELLY SAND BEDDING

Do/3

3" MIN.

PIPE SPRINGLINE

GRAVELLY SAND BEDDING SHALL BE CONSISTENT WITH THE GRADATION AND

OTHER CHARACTERISTICS OF STANDARD AASHTO A1 OR A3 SOIL. A

REPRESENTATIVE SAMPLE OF THE MATERIAL AND A GRADATION REPORT OR

SUPPLIER'S CERTIFICATION OF COMPLIANCE SHALL BE SUBMITTED TO THE

ENGINEER FOR APPROVAL PRIOR TO DELIVERY TO SITE. SEE SOIL DATA IN

APPENDIX OF SPECIFICATIONS BOOKLET.

6" TYP

0" MIN MEASURE POINT FOR

MAXIMUM TRENCH WIDTH

TOP OF

PIPE

CRUSHED ROCK MEETING THE GRADATION OF SUDAS CLASS I BEDDING

MATERAL, SPECIFICATION SECTION 3010.2.02.A, MAY BE SUBSTITUTED FOR

THE SAND OR CLAY HAUNCH BACKFILL MATERIAL. NO COMPACTION WILL BE

REQUIRED FOR THE CRUSHED ROCK BEDDING AND BACKFILL. MATERIAL

COSTS SHALL BE INCIDENTAL TO PIPE INSTALLATION.

MODIFIED TRENCH INSTALLATION TYPE 4

COMPLETELY FILL HAUNCH

AREA WITH NON-SATURATED

SILTY CLAY OR CLAY SOIL.

COMPACT TO 85% STANDARD

PROCTOR DENSITY. THERE

ARE NO SPECIFIED MOISTURE

LIMITS.

Do

WHERE TRENCH BOTTOM IN FIRM UNDISTURBED SOIL,

SHAPE TRENCH BASE GROOVE TO MATCH MINIMUM

1/6 OF THE OUTER CIRCUMFERENCE OF THE PIPE.

WHERE THE SHAPED GROOVE CANNOT BE

CONSTRUCTED INTO UNDISTURBED GROUND OR

WHERE EXCESS CUT OCCURS OVER EXCAVATE AND

PLACE MINIMUM 3-INCH THICK COMPACTED GRAVELLY

SAND BEDDING TO RESTORE GRADE SUCH THAT 1/6 OR

MORE OF THE OUTER CIRCUMFERENCE OF THE PIPE IS

BEDDED. THIS MATERIAL AND WORK IS SUBSIDIARY TO

THE INSTALLATION OF THE PIPE. CONTRACTOR MAY

SUBSTITUTE PIPE BEDDING ROCK AS THE BEDDING

MATERIAL. IT ALSO IS SUBSIDIARY.

PIPE SPRINGLINE

6" TYP

0" MIN MEASURE POINT FOR

MAXIMUM TRENCH WIDTH

TOP OF

PIPE

MINIMUM TRENCH WIDTH SHALL BE OUTSIDE DIAMETER OF PIPE PLUS 12" OR

THAT WIDTH WHICH IS REQUIRED FOR COMPACTION, WHICHEVER IS GREATER

WHERE FIRM BASE IS NOT

ENCOUNTERED. OVER

EXCAVATE AS DIRECTED BY

ENGINEER. PLACE CRADLING

ROCK AND BED PIPE IN IT

SUCH THAT 1/6 OR MORE OF

THE OUTER CIRCUMFERENCE

OF THE PIPE IS SUPPORTED.

THIS ROCK IS PAID FOR UNDER

A SEPARATE BID ITEM.

THE CONTRACTOR IS SOLEY RESPONSIBLE FOR THE INSTALLATION OF ALL PIPE ACCORDING TO PLAN REQUIREMENTS.

THE CONTRACTOR'S PARTICIPATION IN AND COMPLIANCE WITH THE FOLLOWING PROCEDURE IS REQUIRED AND WILL

ALLOW FOR FEWER SOIL DENSITY TESTS TO ENSURE PROPER PIPE INSTALLATION.

STEP 1

BEFORE COMMENCING PIPE INSTALLATION, STANDARD SOIL PROCTOR DENSITY TEST RESULTS OF REPRESENTATIVE SAMPLE(S) OF PIPE HAUNCH FILL SHALL BE PROVIDED BY AN INDEPENDENT QUALIFIED SOILS TESTING LAB. THE SELECTION OF THE SAMPLE(S) WILL BE MADE BY THE ENGINEER AND CONTRACTOR (WHEN SPECIFIED).

STEP 2

CONTRACTOR MAY BEGIN EXCAVATING THE MODIFIED TYPE 4 TRENCH

WITH THE REQUIRED SHAPED BOTTOM GROOVE AND PLACE SEVERAL PIPE SECTIONS ONLY WHEN BOTH ENGINEER AND

TESTING LAB TECHNICIAN ARE PRESENT

CONTRACTOR SHALL DEMONSTRATE THE INTENDED METHODS FOR COMPACTING THE FILL FOR THE PIPE HAUNCH AREAS. SOIL DENSITY TESTS SHALL BE TAKEN AT LOCATIONS DESIGNATED BY THE ENGINEER TO CONFIRM THAT THE INTEDNED METHODS FOR FILL AND COMPACTION OF THE PIPE HAUNCH AREAS SATIFIES THE PLAN REQUIREMENTS.

CONTRACTOR SHALL MODIFIY THE INSTALLATION METHODS AND REPEAT STEP 2 UNTIL ACCEPTABLE TESTS RESULTS ARE

ACHIEVED.

STEP 3

CONTRACTOR MAY INSTALL THE NEXT SEVERAL HUNDRED FEET OF PIPE. ENGINEER SHALL DESIGNATE SEVERAL LOCATIONS (APPROXIMATELY 10% OF THE INSTALLED LENGTH) WHERE CONTRACTOR SHALL LEAVE THE PIPE UNBLINDED FOR FURTHER DENSITY TESTS OF THE HAUNCH FILL AREA. ALL DENSITY TESTS MUST MEET PLAN REQUIREMENTS BEFORE

WORK MAY PROCEED FURTHER.

IF DENSITY TESTING DATA CONFIRMS TO THE SATISFACTION OF THE ENGINEER THAT THE CONTRACTOR'S INSTALLATION METHOD WILL PRODUCE CONSISTENT COMPLIANCE WITH PLAN REQUIREMENTS, CONTRACTOR MAY CONTINUE INSTALLATION OF THE PIPE WITH NO ADDITIONAL TESTING REQUIRED. IF NOT, STEPS 2 AND 3 SHALL BE REPEATED UNTIL A RELIABLE, SUCCESSFUL METHOD OF PIPE INSTALLATION THAT PRODUCES SATISFACTORY RESULTS IS ESTABLISHED.

TRENCH WALLS

PLUG DOWNSTREAM

TILE WITH PLASTIC END

PLUG, CONCRETE, OR

AS OTHERWISE

ALLOWED.FLOW FLOW

CUT AND SHAPE END OF P.E.

TILE TO FIT FLUSH WITH INSIDE

OF CONCRETE TILE. GROUT

CONNECTION

FILL TRENCH TO P.E. SPRINGLINE WITH COMPACTED CRUSHED

STONE. WHERE COVER EXCEEDS 8 FEET, COVER CONNECTION

AND EXPOSED P.E. WITH 12 INCHES OF CRUSHED STONE

BEDDING COMPLYING WITH SUDAS SPECIFICATION SECTION

3010.301. BUCKET PRESS & COMPACT EARTH FILL UNIFORMLY

ON BOTH SIDES OF STONE TO RESIST LATERAL MOVEMENT OF

THE STONE.

CONCRETE COLLAR EXCEPTION

CONNECTIONS TO THE PIPE AT BOTH ENDS MAY BE MADE

WITH A MANUFACTURED POLYETHYLENE INTERNAL SNAP

COUPLER INSERTED FULLY INTO THE PIPE. CONCRETE COLLARS

NOT REQUIRED WITH POSITIVE LOCKED CONNECTION OR

WHERE COMPACTED CRUSHED ROCK FULLY SURROUNDS THE

CONNECTION. GAPS AT THE CONNECTIONS SHALL BE COVERED

WITH ENGINEERING FABRIC WRAPPED AROUND THE JOINT.

INSERTA TEE WILL BE CONSIDERED AS ALTERNATE

CONNECTION AT NEW MAIN WITH ENGINEERS PRIOR

APPROVAL AND INSTALLATION PER MANUFACTURERS

RECOMMENDATION.

TYPICAL FIELD TILE CONNECTION

FOR FIELD TILE UP TO 10" DIAMETER

CO

VE

R

USE NON-PERFORATED

CORRUGATED P.E. DRAIN TILE

UNDISTURBED

SOIL

SLIDE CORRUGATED P.E. TILE A

MINIMUM OF 6" OVER END OF

EXISTING TILE. ENCASE JOINT (IF

NOT TIGHT FITTING) IN P.C.

CONCRETE COLLAR, AS SHOWN.

FIELD TILE

A

A

PIPE HAUNCH FILL AND COMPACTION METHOD

PLAN REQUIREMENTS COMPLIANCE VERIFICATION

12"

6"

HAND SHAPE TRENCH FOR P.E.

TILE TO INSURE UNDISTURBED

SOIL SUPPORT LOWER 1/2 OF

TILE PERIMETER OR BED ON

CRUSHED STONE FILL AND

THOROUGHLY TAMP SOIL

ENVELOPE

SECTION A-A

TOP OF SOIL

ENVELOPE

UNDISTURBED

SOIL

CONTRACTOR IS REQUIRED TO PROPERLY AND ADEQUATELY INSTRUCT SUBCONTRACTORS AND/OR SUBSEQUENT PIPE

INSTALLATION WORKERS ON THE PROPER INSTALLATION METHOD.

STEP 4A

SOIL OR TRENCH CONDITION CHANGES

TO VERIFY CONTRACTOR'S COMPLIANCE WITH PLAN REQUIREMENTS UNDER THE CHANGED CONDITIONS, ENGINEER MAY STOP WORK AND REQUIRE ADDITIONAL SOIL PROCTOR TESTS AND/OR SOIL DENSITY TESTS SIMILAR TO STEPS 1 THROUGH

3. THE WORK AND COSTS OF THE FIRST TWO REVERIFICATIONS IS SUBSIDIARY TO THE PIPE INSTALLATION. SUBSEQUENT

VERIFICATIONS WILL BE CONSIDERED EXTRA WORK.

STEP 4B

CONTRACTOR FAILS TO CONSISTENTLY PERFORM INSTALLATION METHOD OR INSTRUCT OTHER INSTALLERS

IF CONTRACTOR FAILS TO CONSISTENTLY PERFORM OR ADEQUATELY INSTRUCT SUBCONTRACTORS AND/OR SUBSEQUENT PIPE INSTALLATION WORKERS ON THE APPROVED INSTALLATION METHOD, ENGINEER MAY STOP WORK AND REQUIRE ADDITIONAL SOIL PROCTOR TESTS AND/OR SOIL DENSITY TESTS SIMILAR TO STEPS 1 THROUGH 3 TO VERIFY CONTRACTOR'S COMPLIANCE WITH PLAN REQUIREMENTS. THE WORK AND COSTS OF ALL VERIFICATIONS UNDER SUCH

CONDITIONS IS SUBSIDIARY TO THE PIPE INSTALLATION.

EXCEPTION

IF CONTRACTOR ELECTS TO SHAPE THE TRENCH BOTTOM SUCH THAT A MINIMUM OF 45% OF THE OUTER CIRCUMFERENCE OF THE PIPE IS FIRMLY BEDDED IN AND CONSISTENTLY SUPPORTED BY UNDISTURBED SOIL, PIPE HAUNCH FILL COMPACTION TESTING WILL NOT BE REQUIRED. THE CONTRACTOR IS REQUIRED TO COMPLY WITH A PROPER INSTALLATION METHOD AND TO FULLY COMPLY WITH THE REQUIREMENTS OF THE VERIFICATION OUTLINED

ABOVE FOR ALL SITUATIONS WHERE THIS EXCEPTION IS NOT MET.

NOT TO SCALE

SOURCE: AMERICAN CONCRETE PIPE ASSOCIATION

CONCRETE PIPE DESIGN MANUAL

NOT TO SCALE

SOURCE: AMERICAN CONCRETE PIPE ASSOCIATION

CONCRETE PIPE DESIGN MANUAL

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

B0

1.

dw g 9/

/2

8:

:4

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.06

CPDT INSTALLATION DETAIL

FLAT BOTTOM TRENCH INSTALLATION

FILL TRENCH TO 6" ABOVE TOP OF PIPE WITH CRUSHED STONE OR GRAVEL

MEETING THE REQUIREMENTS IN TABLE 2. BEDDING MATERIAL SHALL BE

INCIDENTAL TO THE PIPE INSTALLATION.

PREFFERED TRENCH INSTALLATION BOTTOM

CORRUGATED POLYETHYLENE DRAINAGE TUBING

MATERIAL & INSTALLATION NOTES

NOT TO SCALE

SOURCE: ASTM F449

TRAPEZOIDAL GROOVE, "V" GROOVE, & CIRCULAR GROOVE

NOT TO SCALE

SOURCE: ASTM F449

6" MIN FOR

OPEN TRENCH

INSTALLATION

R

6" M

IN

A B G

0.

5R

0.

R

TRENCH WIDTH MEASURED

AT TOP OF PIPE

90° "V" GROOVE

90°

THE CIRCULAR GROOVE SHALL BE A

MINIMUM 0.35R DEEP AND SHALL

MATCH THE OUTSIDE CURVE

SHAPE OF THE DEFLECTED CPDT.

THE TRAPEZOIDAL GROOVE SHALL

BE SHAPED AND ADJUSTED SUCH

THAT POINTS A, B, & C WILL TOUCH

THE UNDEFLECTED CPDT FOR EACH

SIZE INSTALLED.

TRAPEZOIDAL GROOVE

CIRCULAR GROOVE

UNDISTURBED SOIL

UNDISTURBED SOIL

TRENCH WIDTH MEASURED

AT TOP OF PIPE

4" M

IN

SEE TABLE 2 FOR

BEDDING MATERIAL

NOTE: THIS IS AN ALLOWED ALTERNATIVE INSTALLATION FOR CPDT

1. ALL CPDT AND CONNECTORS FURNISHED SHALL BE IN COMPLIANCE WITH MATERIAL STANDARDS ASTM F405 AND F667, AS

APPLICABLE, AND SHALL BE CLASSIFIED AS HEAVY-DUTY UNDER THOSE STANDARDS.

2. EXCEPT MODIFIED HEREIN OR OTHERWISE APPROVED BY ENGINEER, ALL CPDT SHALL BE INSTALLED IN COMPLIANCE WITH THE

ASTM 449 STANDARD PRACTICE.

3. FOR PIPES 6” DIAMETER AND SMALLER A 90° V GROOVE BOTTOM MAY BE USED, FOR ALL LARGER PIPE A TRAPEZOIDAL BOTTOM OR A CIRCULAR BOTTOM CONFORMING TO THE OUTSIDE DIAMETER OF THE PIPE SHALL BE USED. PRIOR TO THE INSTALLATION OF CPDT, CONTRACTOR MUST PROVE TO ENGINEER THAT THE INSTALLATION REQUIREMENTS, INCLUDING THE

SHAPE OF THE TRENCH BOTTOM, WILL BE ACCOMPLISHED.

4. WHERE TRENCH BOTTOM IS IN FIRM UNDISTURBED SOIL, SHAPE TRENCH BASE GROOVE. WHERE EXCESS CUT OCCURS, OVEREXCAVATE AND PLACE MINIMUM THREE (3) INCH THICK, GRAVELLY SAND BEDDING TO RESTORE GRADE. THIS BEDDING SHALL MEET THAT REQUIRED FOR TRENCH INSTALLATION TYPE 3 ON PLAN SHEET B.02. THIS MATERIAL AND WORK SHALL BE INCIDENTAL TO THE INSTALLATION OF THE PIPE. CONTRACTOR MAY SUBSTITUTE PIPE BEDDING ROCK AS THE BEDDING

MATERIAL.

5. NATIVE SOILS MAY BE USED AS BACKFILL MATERIAL UNLESS UNSTABLE TRENCH CONDITIONS PREVENT THE TRENCH BOTTOM HOLDING THE SHAPED GROOVE. IF TRENCH BOTTOM WILL NOT HOLD GROOVE SHAPE CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY. A FLAT BOTTOM TRENCH INSTALLATION WILL THEN BE ASSUMED. THE REQUIRED BEDDING MATERIAL SHALL BE

INCIDENTAL TO THE INSTALLATION OF THE PIPE.

6. MINIMUM TRENCH WIDTH IS PIPE OUTSIDE DIAMETER PLUS FOUR (4) INCHES FOR PLOWED INSTALLATION AND PIPE OUTSIDE

DIAMETER PLUS TWELVE (12) INCHES FOR OPEN TRENCH INSTALLATION.

7. ALL LATERAL CONNECTIONS, ELBOWS, TEES, ALIGNMENT CURVES, START HOLES AND ALL PORTIONS OF THE TRENCH NOT MEETING THE GROOVED TRENCH INSTALLATION REQUIREMENTS SHALL BE FILLED TO A MINIMUM OF SIX (6) INCH COVER OVER THE PIPE WITH GRADED CRUSHED STONE OR GRAVEL AS SHOWN ON TABLE 2 OF THIS SHEET. BEDDING MATERIAL SHALL BE

INCIDENTAL TO THE INSTALLATION OF THE PIPE.

8. MANUFACTURER'S ENDCAPS SHALL BE INSTALLED AT THE TERMINATION OF EACH LINE UNLESS A CONNECTION TO AN EXISTING

DRAIN IS MADE.

9. WITH THE INSTALLATION OF THE FIRST REACH OF CPDT ON THE PROJECT, CONTRACTOR IS REQUIRED TO WORK WITH THE

ENGINEER TO CHECK AND CONFIRM THAT THE PIPE STRETCH, IF ANY, DOES NOT EXCEED 5%.

10. ALIGNMENT TURNS MAYBE MADE USING EITHER A MANUFACTURED FITTING OR CURVING THE LINE WITH A 25' MINIMUM

RADIUS.

R25'

PI

X °

PT

PT

Table 1 Maximum Allowable Buried Depth to Flowline of CPDT

Nominal Pipe Diameter (IN)

Pipe Quality

(ASTM)

Trench Width at Top of the Pipe (FT)

12" 18" 24" 30" or Greater

Standard 13 7 5.5 5

Heavy-duty Any 10 7 6

Standard 10 7 5.5 5

Heavy-duty Any 9.5 6.5 6

Standard 10 7 5.5 5

Heavy-duty Any 10 7 6

10 Heavy-duty ... 9 7 6 12 Heavy-duty ... 9 7 6 15 Heavy-duty ... ... 7 6

Table 2 Acceptable Bedding Material and Compaction Requirements

Description Percentage Passing Sieve Sizes Minimum

Standard Density (%)

Maximum Compaction Layer Height

(IN.)1" 3/4" No. 4

Crushed Stone Crushed Gravel* 100% > 95% < 5% Dumped 18

* Class 1 Bedding Material Per SUDAS 3010.202A is an Allowable Substitute

DEGREES Δ DELTA

20° 4.41 30° 6.7 45° 10.36 60° 14.43 70° 17.51 80° 20.98 90° 25

DISTRICT TILE MAIN SHALL BE

INSTALLED WITH A FLAT BOTTOM

TRENCH AND BEDDED AS SHOWN.

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

C0

1.

dw g 9/

/2

8:

:5

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

C.01

ESTIMATED QUANTITIES

Bid Item Description Specifications

Plan No.

Estimated Quantities

No. Page Quantity Unit

1 Site Stripping & Preparation IA CS-001 3 A.02 1 LS

2 Crop Damage IA CS-001 3 - 0 AC

3 Buffer Seeding IA CS-006 7 K.01 26.6 AC

4 Structure Seeding IA CS-006 7 K.01 0.4 AC

5 Mobilization and Demobilization IA CS-008 11 - 1 LS

6 Drain Tile Investigation and Removal IA CS-009 14 A.04 4 HR

7 Excavation (General) IA CS-021 20 D.01 13571 CY

8 Earthfill (General) IA CS-023 22 D.01, M.03 334 CY

9 Topsoil Stripping, Stockpiling, & Placement IA CS-026 26 D.01 344 CY

10 12" Dia. Reinforced Concrete Pipe IA CS-031 28 B.04, M.03 168 LF

11 15" Dia. Reinforced Concrete Pipe IA CS-031 28 B.04, M.02 35 LF

12 18" Dia. Reinforced Concrete Pipe IA CS-031 28 B.04, M.03 151 LF

13 12" Reinforced Concrete Apron, Footing, Bar Guard IA CS-031 28 M.03 1 EA

14 Modified SW-513 Inlet Structure (48" x 48") IA CS-031 28 B.02, M.03 1 EA

15 Modified SW-513 Outlet Structure (48" x 48") IA CS-031 28 B.01, M.03 1 EA

16 SW-401 Concrete Manhole Structure IA CS-031 28 M.01-M.02 2 EA

17 SW-401 Pump Basin IA CS-031 28 B.03, M.02 1 EA

18 Solar Pump System IA CS-031 28 B.03, M.03 1 EA

19 6" Dia. Corrugated HDPE Pipe (Dual-Wall, Non-Perforated) IA CS-046 36 B.05, M.02 662 LF

20 18" Dia. Corrugated HDPE Pipe (Dual-Wall, Non-Perforated) IA CS-046 36 B.05, M.01 1150 LF

21 Rip Rap (Class E) IA CS-061 40 M.02-M.03 28.4 TN

22 Clean Existing Tile Main (526 LF) IA CS-046 1 LS

900900

894894

898898

896896

896896

5 894 l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l

100-YEAR HWL = 893.50

4 FT WIDE COVER BERM

TOP ELEV. 898.50

GRADE AT 6:1 SLOPE

SPOIL AREA EXTENTS

30 FT WIDE INLET CHANNEL

ELEV. 891.25

GRADE AT 4:1 SLOPE

EXCAVATE POOL TO 891.25

GRADE AT 4:1 SLOPE

EXCAVATE POOL TO 891.25

GRADE AT 4:1 SLOPE

PRESERVE EXISTING

UTILITY POLE

PROTECT EXISTING CITY

OF AMES WATER MAIN

SEDIMENT FOREBAY

ELEV. 888.25

GRADE AT 2.5:1 SLOPE

DIVERSION BERM

10 FT TOP, 4:1 SIDES

TOP ELEV = 891.75

DIVERSION BERM

10 FT TOP, 4:1 SIDES

TOP ELEV = 891.75

EXCAVATE POOL TO 891.25

894896897898899

10.00% 2.16%

.0

8%

10.16%

SPOIL PILE

NORMAL POOL (892.50)

100-YEAR HWL (893.82)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 891.50

MINIMUM 6" TOPSOIL LAYER

LEGEND

l l l l l l l l l l l l l l

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

D0

1.

dw g 9/

/2

8:

:2

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

D.01

GRADING OVERVIEW

R

FEETSCALE

0 50 100

HORZ.

1" = 200'

EARTHWORK QUANTITIES

EXCAVATION (POOL, INLET CHANNEL, SEDIMENT FOREBAY): 13,570 CY

EARTHFILL (COVER BERM, DIVERSION BERMS): 334 CY

SPOIL (6" SPREAD OVER AREAS SHOWN): 13,236 CY

SEED COVER BERM

STRUCTURE SEEDING

SEED DISTURBED AREAS TO

1 FT BELOW NORMAL POOL

STRUCTURE SEEDING

SEED DISTURBED AREAS TO

1 FT BELOW NORMAL POOL

BUFFER SEEDING

SEED DISTURBED AREAS TO

1 FT BELOW NORMAL POOL

BUFFER SEEDING

SEED BUFFER AREA TO

EASEMENT BOUNDARY

BUFFER SEEDING

SEED BUFFER AREA TO

EASEMENT BOUNDARY

BUFFER SEEDING

SEED FINAL SPOIL AREA

BUFFER SEEDING

SEEDING AREAS

BUFFER SEEDING 26.6 AC

STRUCTURE SEEDING 0.4 AC

SPOIL AREA EXTENTS

894 893

6 89

7 89

DO NOT SEED POOL

SEED BUFFER AREA TO

EASEMENT BOUNDARY

BUFFER SEEDING

SPOIL AREA EXTENTS

NORMAL POOL (892.25)

100-YEAR HWL (893.82)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 891.25

STRUCTURE SEEDING

BUFFER SEEDING

FLOW PATH THROUGH WETLAND

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

K0

1.

dw g 9/

/2

8:

:4

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

K.01

SEEDING OVERVIEW

R

FEETSCALE

0 50 100

EXISTING 16" C

ONCRETE TILE

TOP = 889.04

FL =

887.71

0+00 1+00 1+50

BP

: 0

+0 0.

EP

: 1

+5 0.

RIP RAP

11 FT x 10 FT

8.7 TONS

SOLAR PANEL LOCATION

INSTALL ABOVE 898.50

(STA 0+58)

SW-401 (48in)

CASTING: SW-602 TYPE E

TOP = 895.83

FL IN = 887.69 (16" NW)

FL OUT = 887.69 (18" SE)

FL OUT = 886.18 (15" SW)

PUMP BASIN (STA 1+17)

MODIFIED SW-401 (48")

SEE B.03

TOP = 895.50

FL IN = 885.81 (15" NE)

EXISTING DD 39 16" TILE

892894

-0+25 0+00 1+00 2+00

4.

4.

3.

3.

3.

2.

2.

6.

6.

5.

-0.50%

STA: 0+42.34

EL: 886.18

STA: 1+17.50

EL: 885.81

75' - 15" RCP @ 0.50%

75 LF - 15" RCP

@ 0.50% 1742

PU

M

P

BA

SI

N

(S

TA

+1

7) M

O

DI

FI

ED

S W

-4

(4 8"

SE

E B.

TO

P

5.

FL

IN

.8

(1 5"

N E)

EXISTING SURFACE NWL = 892.25

EXCAVATED POOL

(S

TA

+5

0)

SW

-4

(4 8i n)

CA

ST

IN

G:

S

W -6

T

YP

E

E

TO

P

5.

FL

IN

.6

(1 6"

N W

FL

O U

T

7.

(1

8" S

E)

FL

O U

T

6.

(1

5" S

W

PROVIDE MARKER FLAG

NORMAL POOL (892.25)

100-YEAR HWL (893.82)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 891.25

STRUCTURE SEEDING

LEGEND

EXISTING 16" CONCRETE TILE

TOP = 887.77

FL = 886.44

0+00 1+00 2+00

BP

: 0

+0 0.

EP

: 2

+0 0.

RIP RAPSEE B.01

0.6 TONS>> >> >> >> >>

OUTLET STRUCTURE (STA 0+25)

MODIFIED SW-513

SEE B.01

TOP = 893.50

OPENING = 892.25

FL OUT = 887.96 (18" SE)

(STA 1+76)

SW-401 (72in)

CASTING: SW-602 TYPE E

TOP = 894.70

FL IN = 886.52 (18" NW)

FL IN = 886.52 (18" N)

FL OUT = 886.52 (18" SE)

-0+50 0+00 1+00 2+00 2+50

2.

2.

2.

2.

2.

2.

2.

2.

2.

2.

2.

2.

2.

2.

2.

2.

O U

TL

ET

S

TR

U

CT

U

RE

(S

TA

+2

5) M

O

DI

FI

ED

S W

-5

SE

E

B.

TO

P

3.

O

PE

N

IN

G

2.

FL

O U

T

7.

(1

8" S

E)

131' - 18" RCP @ 1.10%

131 LF - 18" RCP

@ 1.10% 5625

-1.10%

STA: 0+25.00

EL: 887.96 STA: 1+55.77

EL: 886.52

EXISTING SURFACE

EXISTING 18" DD 39 TILE

NWL = 892.25

EXCAVATED POOL

ST

A 1+

SW

-4

(7

2i n)

CA

ST

IN

G:

S W

-6

T

YP

E E

TO

P

4.

FL

IN

.5

(1

8" N

W

FL

IN

.5

(1

8" N

FL

O U

T

6.

(1

8" S

E)

PROVIDE MARKER FLAG

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

M

.d w g

9/

/2

8:

:0

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

FEETSCALE

0 25 50

HORZ.

FEETSCALE

0 5 10

VERT. M.01

PLAN & PROFILE - PUMP INLET PIPE & OUTLET PIPE

R

PUMP INLET PIPE

R

OUTLET PIPE

CLEAN PIPE DOWNSTREAM OF CONNECTION

-0+50 0+00 1+00 2+00 2+50

9.

6.

7.

6.

5.

5.

5.

5.

5.

5.

3.

3.

3.

3.

3.

3.

-0.30%

STA: 0+27.96

EL: 894.00

STA: 1+92.69

EL: 893.50

IN

LE

T

ST

RU

CT

U

RE

(S

TA

+2

8) M

O

DI

FI

ED

S W

-5

TO

P

7.

O

PE

N

IN

G

6.

FL

O U

T

4.

(1

2" W

ST

A

1+

" A

PR

O

N , F

O O

TI

N

G, B

AR

G

U

AR

D

FL

IN

.5

(1 2"

E

165' - 12" RCP @ 0.30%

165 LF - 12" RCP

@ 0.30% 9328

6:1EXISTING SURFACE

COVER BERM

TOP ELEV. 898.50

NWL = 892.25

EXCAVATED SEDIMENT FOREBAY

0+00

1+00

2+00 2+25

BP

: 0

+0 0.

EP

: 2

+2 5.

00RIP RAP

10.5 TONS

TOP OF RIP RAP = 895.50

INLET STRUCTURE (STA 0+28)

MODIFIED SW-513

TOP = 897.25

OPENING = 896.00

FL OUT = 894.00 (12" W)

STA 1+93

12" APRON, FOOTING, BAR GUARD

FL IN = 893.50 (12" E)

COVER BERM

TOP ELEV. 898.50

RIP RAP

10 FT x 11 FT

8.7 TONS

NORMAL POOL (892.25)

100-YEAR HWL (893.82)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 891.25

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

M

.d w g

9/

/2

8:

:0

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 25 50

HORZ.

FEETSCALE

0 5 10

VERT. M.02

PLAN & PROFILE - DITCH INLET PIPE

DITCH INLET PIPE

-1+25 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 13+75

4.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

2.

2.

2.

2.

2.

4.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

3.

2.

2.

2.

2.

2.

-0.09%

STA: 0+65.87

EL: 887.46 STA: 12+26.30

EL: 886.39

(S

TA

+5

0)

SW

-4

(4 8i n)

CA

ST

IN

G:

S

W -6

T

YP

E

E

TO

P

5.

FL

IN

.6

(1 6"

N W

FL

O U

T

7.

(1

8" S

E)

FL

O U

T

6.

(1

5" S

W

ST

A

+2 2)

SW

-4

(7

2i n)

CA

ST

IN

G:

S W

-6

T

YP

E E

TO

P

4.

FL

IN

.5

(1

8" N

W

FL

IN

.5

(1

8" N

FL

O U

T

6.

(1

8" S

E)

ST

A

8+

° E

LB

O

W

FL

IN

.8

(1 8"

N W

FL

O U

T

6.

(1

8" S

30 FT INLET CHANNEL

BOTTOM ELEV. 891.25

EXISTING SURFACE

EXISTING DD 39 16" TILE

EXISTING DD 39 18" TILE

NWL = 892.25

DRAINAGE DISTRICT TILE CAPACITIES

EXISTING: 16" @ 0.1% = 2.10 CFS

PROPOSED: 18" @ 0.09% = 3.41 CFS

l l l l l l l l

0+00

1+00

2+00

3+00

4+00

5+00

6+00

7+00

8+00

9+00

10+00

11+00

11+75BP

: 0

+0 0.

PI

: 8

+2 8.

EP

: 1

1+

.0

0+00

1+00

2+00

3+00

4+00

5+00

6+00

7+00

8+00

9+00

10+00

11+00

11+75BP

: 0

+0 0.

PI

: 8

+2 8.

EP

: 1

1+

.0

(STA 0+50)

SW-401 (48in)

CASTING: SW-602 TYPE E

TOP = 895.83

FL IN = 887.69 (16" NW)

FL OUT = 887.69 (18" SE)

FL OUT = 886.18 (15" SW)

(STA 11+22)

SW-401 (72in)

CASTING: SW-602 TYPE E

TOP = 894.70

FL IN = 886.52 (18" NW)

FL IN = 886.52 (18" N)

FL OUT = 886.52 (18" SE)

STA 8+29

30° ELBOW

FL IN = 886.84 (18" NW)

FL OUT = 886.84 (18" S)

898898

892 893

896896

RING TILE

SEE M.02

OUTLET PIPE

SEE M.01

PUMPED INLET PIPE

SEE M.02

EXISTING DD 39 16" TILE

EXISTING DD 39 18" TILE

NORMAL POOL (892.25)

100-YEAR HWL (893.82)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 891.25

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

M

.d w g

9/

/2

8:

:3

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 50 100

HORZ.

FEETSCALE

0 5 10

VERT. M.03

PLAN & PROFILE - TILE RE-LAY

TILE RE-LAY

CLEAN PIPE DOWNSTREAM OF CONNECTION

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 7+50

5.

5.

5.

5.

5.

5.

4.

4.

4.

4.

4.

4.

4.

4.

4.

4.

4.

4.

4.

4.

4.

4.

3.

3.

3.

3.

3.

3.

3.

3.

3.

7.

7.

7.

7.

7.

7.

7.

7.

7.

7.

7.

7.

7.

8.

8.

8.

8.

8.

8.

-0.10% 0.10%

STA: 3+00.00

EL: 887.94

STA: 4+24.67

EL: 887.81

STA: 7+50.00

EL: 888.14

125' - 6" HDPE @ 0.10%

125 LF - 6" DUAL-WALL

NON-PERF. HDPE

@ 0.10% 2500

ST

A 3+

CA

P

EN

D O

F

PI

PE

FL

O U

T

7.

(6

" W

ST

A

4+

TE

E

IN

TO

E

XI

ST

IN

G

TI

LE

FL

IN

.8

(6 " E

FL

IN

.8

(6 " W

EXISTING GROUND SURFACE

325' - 6" HDPE @ 0.10%

325 LF - 6" DUAL-WALL

NON-PERF. HDPE

@ 0.10%25 50

ST

A

7+

TI

E

IN

E

XI

ST

IN

G

TI

LE

FL

O

U T

8.

(6 " E

EXISTING DD 39 16" TILE

EXISTING 16" CONCRETE TILE

TOP = 889.04

FL = 887.71

REMOVE EXISTING INTAKE

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00

BP

: 0

+0 0.

STA 3+00

CAP END OF PIPE

FL OUT = 887.94 (6" W)

STA 4+25

TEE INTO EXISTING TILE

FL IN = 887.81 (6" E)

FL IN = 887.81 (6" W)

(STA 3+96)

SW-401 (48in)

CASTING: SW-602 TYPE E

TOP = 895.83

FL IN = 887.69 (16" NW)

FL OUT = 887.69 (18" SE)

FL OUT = 886.18 (15" SW)

895 894

EXISTING DD 39 16" TILE

NORMAL POOL (892.25)

100-YEAR HWL (893.82)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 891.25

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c h:

\I

DA

LS

\2

5x

0\

CA

D\

C3 D\

M

.d w g

9/

/2

8:

:4

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

IDALS PROJECT NO. STO842436B

BCS

NVD

JPR

25X.138711.000

1.1 IDALS REVISIONS 02-09-2026

1.2 PERMIT PLANS 05-20-2026

1.3 PERMIT PLANS REV. 2 09-15-2026

1519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 25 50

HORZ.

FEETSCALE

0 5 10

VERT. M.04

PLAN & PROFILE - RING TILE

RING TILE

Sheets and Views
A.01 TITLE SHEET
A.02 PLAN OVERVIEW
A.03 SITE OVERVIEW
A.04 EXISTING CONDITIONS & REMOVALS
B.01 INLET STRUCTURE DETAIL
B.02 OUTLET STRUCTURE DETAIL
B.03 TRASH GUARD DETAIL
B.04 PUMP BASIN & SOLAR ARRAY DETAILS
B.05 RCP INSTALLATION DETAIL
B.06 CPDT INSTALLATION DETAIL
C.01 ESTIMATED QUANTITIES
D.01 GRADING OVERVIEW
K.01 SEEDING OVERVIEW
M.01 PLAN & PROFILE - PUMP INLET PIPE & OUTLET PIPE
M.02 PLAN & PROFILE - DITCH INLET PIPE
M.03 PLAN & PROFILE - TILE RE-LAY
M.04 PLAN & PROFILE - RING TILE