5 Plans.pdf
PDF 8 MB Posted
- Attached to
- 26-18 Sto842436B (Story)
- Solicitation number
- 26-18 Sto842436B (Story)
- Issued by
- Taylor County, Iowa
About this file
This file contains five architectural and engineering plans for a state or local infrastructure project. The plans include site plans, floor plans, elevation drawings, and utility layouts that appear to support a construction or renovation project. The document provides detailed specifications for spatial configurations, building dimensions, material designations, and site improvements. The plans establish the baseline design requirements and technical specifications that bidders must reference when preparing proposals and cost estimates. While specific response dates, bid due dates, site visit schedules, and bidders' meetings are not detailed within the plans themselves, these drawings serve as essential contract documents that define the scope of work and project deliverables.
The plans do not contain explicit pricing terms, set-asides, incumbent information, funding sources, or contract duration details. As technical specification documents, the plans function as reference materials to be incorporated into the broader solicitation package alongside separate procurement documents, budget information, and contractual terms. Bidders should cross-reference these plans with the main solicitation notice and any associated amendments or addenda for complete information regarding pricing, evaluation criteria, contract period, and other material terms.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2 BID BOOK.pdf | ||
| 6 Design Report.pdf | ||
| 9 Bid Bond.pdf | ||
| 8 Proposal - Acknowledgement - Affidavit.pdf | ||
| 3 Bid Book.pdf | ||
| 1 Notice to Bidders.pdf | ||
| 7 Schedule of Prices.pdf | ||
| 4 Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T AVE
SW
RD
S
T
TH
S T
0T
H A
V E
0T
H A
V E
0T
H A
V E
0T
H A
V E
210TH ST
X AVE
272ND ST
250TH ST
0T
H A
V E
5T
H A
V E
5T
H A
V E
0T
H A
V E
0T
H A
V E
240TH ST
0T
H A
V E
0T
H A
V
E260TH ST
0T
H A
V E
270TH ST
200TH ST
563RD
A
V E
200TH ST
170TH ST
0T
H A
V E
A
RR
A
SM
ITH
T
RA
IL
G
RA
N T
A V
E
RIVERSIDE RD
215TH ST
280TH ST
LINCOLN HWY
TH
S T
260TH ST
270TH ST
0T
H A
V E
220TH ST
LINCOLN HWY
0T
H A
V
E LINCOLN HWY
260TH ST
260TH ST
0T
H A
V E
0T
H A
V E
0T
H A
V E
170TH ST
0T
H A
V E
190TH ST
0T
H A
V E
170TH ST 170TH ST
0T
H A
V E
0T
H A
V E
190TH ST
190TH ST
0T
H A
V E
210TH ST
0T
H A
V E
170TH ST
0T
H A
V E
280TH ST280TH ST
C O
UN
TR
Y C
LU
B
RD
250TH ST
220TH ST
6T
H A
V E
0T
H A
V E
0T
H A
V E
0T
H A
V E
W MAPLE AVE
SA
N
D H
ILL
T
R
245TH ST
250TH ST
270TH ST
270TH ST
0T
H A
V E
265TH ST
TIM
BE
R
RD
0T
H A
V E
180TH ST
0T
H A
V E
210TH ST
5T
H A
V E
0T
H A
V E 59
0T H
A V
E
0T
H A
V
E180TH ST
N . D
A
YT
O N
A V
E
0T
H A
V E
200TH ST
0T
H A
V E
0T
H A
V E
210TH ST
160TH ST
0T
H A
V E
0T
H A
V E
G
RA
N T
A V
E
180TH ST180TH ST
190TH ST
G
EO
RG
E
W
C A
RV
ER
A V
E
T AVE
175TH ST
N O
RT
H
D A
KO
TA
A V
E
ZUMWALT
STATION RD
SOUTH
S AVE
280TH
ST
G
EO
RG
E
W
C A
RV
ER
A V
E
220TH ST
2N
D A
V E
ONTARIO ST
9T
H
AV
E
STA
G
EC
O
A C
H RD
RI
V
ER
SI
D E
D R
DARTMOOR RD
C
ED
A R
LN
0T
H A
VE
180TH ST
190TH ST
5T
H A
V E
N . D
A
YT
O N
A V
E
7T
H A
V E
SO
UT
H D
A
KO
TA
A
V E
275TH
ST
GILBERT
AMES
NEVADA
KELLEY
Onion
Cr ee k
S q ua w
C reek
Sk un k
R iv er
C re ek
G ra nt
O pen
Ditch
In d ia n
W est
W alnut
S kunk
Cre ekW or le
NAT'L
ANIMAL
DISEASE
CENTER
I.S.U.
HORT.
FARM
IOWA
STATE
UNIVERSITY
SHIPLEY
SOPER'S
MILL
ACCESS
McFARLAND
PARK
PETERSON
PARK R I C H L A N D
M I L F O R D
F R A N K L I N
W A S H I N G T O N
G R A N T
N E V A D A
23456
7 8 9 11
131415161718
19 20 21 23 24
31 32 36
23456
7 8 9 11 12
131415161718
19 20 22 23 24
2627282930
32 33 34 35 36
7 8
19 20
131718
19 21 22 23
252627282930
33 34 35 36
7 8 9 11
131415161718
19 20 21 23 24
252627282930
31 32 33 34 35 36
19 20
31 32
STATE
NURSERY
E23 E23
E57
R63 R50
E26
R38
R63
E29 R77
E41
S14
E29
R38
E57
R70
S14
CAMERON SCHOOL RD
AMES
MUNICIPAL
AIRPORT S
D A
YT
O
N A
V E
R50
OLD BLOOMINGTON RD
W
RD
S
T
‒‒119
‒‒118
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
A0
1.
dw g 9/
/2
8:
:0
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
A.01
TITLE SHEET
PROJECT DATUM: STATE PLANE
HORIZONTAL: IOWA NORTH
VERTICAL: NAVD 1988
MY LICENSE RENEWAL DATE IS
PAGES OR SHEETS COVERED BY THIS SEAL:
LICENSE NUMBER: DATE:
I OWA
LI
CE
NS
ED
PROFESS IONAL ENG
INEER
I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS
PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF IOWA.
29449
12/31/2026
ALL SHEETS
BRANDON C.
SHORT
29449
BRANDON C. SHORT, PE
STORY COUNTY, IA
CONSTRUCTION PLANS FOR
IDALS NO. STO842436B
NUTRIENT REDUCTION WETLAND
STORY COUNTY, IOWA
SEPTEMBER 2026
THE SPECIFICATIONS AS PREPARED BY IOWA DEPARTMENT OF AGRICULTURE
AND LAND STEWARDSHIP AND BOLTON & MENK, INC. SHALL BE CONSIDERED
AS PART OF THIS DOCUMENT. NATURAL RESOURCES CONSERVATION SERVICE
CONSTRUCTION SPECIFICATIONS SHALL APPLY.
THE CURRENT EDITION OF THE "IOWA STATEWIDE URBAN STANDARD
SPECIFICATIONS FOR PUBLIC IMPROVEMENTS" SHALL GOVERN.
IOWA DEPARTMENT OF TRANSPORTATION "STANDARD SPECIFICATIONS FOR
HIGHWAY AND BRIDGE CONSTRUCTION" AND ALL CURRENT GENERAL
SUPPLEMENTAL SPECIFICATIONS AND MATERIALS INSTRUCTIONAL
MEMORANDUM SHALL GOVERN AS REFERENCED.
ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS AND ORDINANCES WILL BE
COMPLIED WITH IN THE CONSTRUCTION OF THIS PROJECT.
GOVERNING SPECIFICATIONS
THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS UTILITY QUALITY
LEVEL D. THIS UTILITY QUALITY LEVEL WAS DETERMINED ACCORDING TO
THE GUIDELINES OF CI/ASCE 38-02, ENTITLED "STANDARD GUIDELINES FOR
THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA."
THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING IOWA ONE CALL BY
PHONE AT 811, OR ON THE WEB AT
HTTP://WWW.IOWAONECALL.COM/. THIS IS REQUIRED BY LAW.
TICKET# ___________.
TICKET NUMBER MUST BE PROVIDED TO THE ENGINEER AND IDALS PRIOR
TO COMMENCEMENT OF WORK.
NRCS, IDALS, and the engineer make no representation as to the existence or nonexistence of any utility, public and/or private, buried or overhead, except as shown on the drawings. Where utilities are shown on the drawings, the location, depth and/or height are approximate. The exact location, depth and/or height must be determined by the utility company and/or the land owner prior to any construction within the project vicinity.
NOTES
1. IF A CULTURAL RESOURCE IS IDENTIFIED DURING
CONSTRUCTION, STOP WORK IMMEDIATELY AND NOTIFY
THE LOCAL NATURAL RESOURCES CONSERVATION SERVICE
OFFICE.
2. THERE IS NO GUARANTEE THAT THE WETLAND WILL FILL OR
REMAIN FILLED WITH WATER.
R-24W
PROJECT
LOCATION
T-
N
CONSERVATION PRACTICE STANDARDS USED:
656 - CONSTRUCTED WETLAND
NRCS JOB CLASS: IV
300 AC < WATERSHED AREA < 1000 AC
TO THE BEST OF MY PROFESSIONAL KNOWLEDGE,
JUDGEMENT, AND BELIEF, THESE PLANS MEET APPLICABLE
NRCS STANDARDS AND APPLICABLE LAWS AND
REGULATIONS.
R
FEETSCALE
0 1 2
SHEET INDEX
SHEET NO. SHEET TITLE
A.01 TITLE SHEET
A.02 PLAN OVERVIEW
A.03 SITE OVERVIEW
A.04 EXISTING CONDITIONS & REMOVALS
B.01 INLET STRUCTURE DETAIL
B.02 OUTLET STRUCTURE DETAIL
B.03 TRASH GUARD DETAIL
B.04 PUMP BASIN & SOLAR ARRAY DETAILS
B.05 RCP INSTALLATION DETAIL
B.06 CPDT INSTALLATION DETAIL
C.01 ESTIMATED QUANTITIES
D.01 GRADING OVERVIEW
K.01 SEEDING OVERVIEW
M.01 PLAN & PROFILE - PUMP INLET PIPE & OUTLET PIPE
M.02 PLAN & PROFILE - DITCH INLET PIPE
M.03 PLAN & PROFILE - TILE RE-LAY
M.04 PLAN & PROFILE - RING TILE
T-
N
R-23W R-22W
T-
N T-
N
R-24W R-23W R-22W brandon.short Text Box 9/16/2026 l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l
900900
CITY OF AMES
CITY OF AMES
CITY OF AMES
KEPLEY, DANNY LEE
& SUSAN LYNN
KEPLEY, DANNY LEE
& SUSAN LYNN
KEPLEY, DANNY LEE
& SUSAN LYNN
MILLEMAN PRAIRIE
FARMS LLC
OLSON, BERNARD DEAN
INLET STRUCTURE
MODIFIED SW-513
DITCH INLET PIPE
12" RCP
30 FT INLET CHANNEL
EXCAVATE POOL TO 891.25
SOLAR-POWERED PUMP BASIN
PUMP INLET PIPE
15" RCP
SW-401
DD 39 TILE RE-LAY
18" DUAL-WALL HDPE
SW-401
EXISTING DD 39 18" TILE
JET TO DOWNSTREAM INTAKE
OUTLET PIPE
18" RCPOUTLET STRUCTURE
MODIFIED SW-513
NWL = 892.25
CONSTRUCTION ACCESS
EXISTING DD 39 16" TILE
PROPERTY LINES
PROPOSED EASEMENT BOUNDARY
SOLAR PANEL LOCATION
INSTALL ABOVE 898.50
CITY OF AMES EXISTING WATER MAIN
RING TILE
6" HDPE
4 FT WIDE COVER BERM
100-YEAR HWL = 893.82
SEDIMENT FOREBAY
DIVERSION BERM
DIVERSION BERM
NORMAL POOL (892.25)
100-YEAR HWL (893.82)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 891.25
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
A0
2.
dw g 9/
/2
8:
:3
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
A.02
PLAN OVERVIEW
R
FEETSCALE
0 60 120
HORZ.
DESIGN CRITERIA VALUE UNIT REQUIREMENT
PUMPED WATERSHED AREA 354.1 ACRES
PUMP PEAK FLOW 0.98 CFS
PUMP PERCENT CAPTURE 48.7 %
EFFECTIVE TREATED PUMPED WATERSHED 172.0 ACRES
DITCH WATERSHED AREA 661.5 ACRES
DITCH PERCENT CAPTURE 92.7 %
EFFECTIVE TREATED DITCH WATERSHED 613.0 ACRES
TOTAL EFFECTIVE TREATED WATERSHED AREA 785.0 ACRES
SURFACE WATERSHED AREA 382.6 ACRES
POOL NORMAL WATER LEVEL (NWL) ELEV 892.25 FT
DESIGNED WETLAND POOL AREA (@ NWL) 4.9 ACRES
PERCENT POOL AREA TO WATERSHED AREA 0.6 % Range 0.5% to 2% of watershed area
MAXIMUM POOL DEPTH 1.75 FT
AVERAGE POOL DEPTH 1.0 FT
DEEP WATER AREA (DEPTH > 3 FT) 0.0 ACRES
PERCENT DEEP WATER TO POOL AREA 0.0 % Less than 25%
POOL STORAGE VOLUME AT NWL 4.8 ACRE-FT
OVERFLOW ELEVATION 893.07 FT Natural Overflow
POOL STORAGE VOLUME AT OVERFLOW 10.7 ACRE-FT
PRIMARY WEIR ELEVATION 892.25 FT Conveys Tile Flow Only PRIMARY WEIR WIDTH 16 FT Modified SUDAS SW-513 Outlet Structure
TOTAL EASEMENT AREA 31.8 ACRES
AREA OF BUFFER 26.9 ACRES
RATIO BUFFER AREA TO NWL POOL AREA 5.4
25-YEAR STORM HWL IN POOL 893.69 FT
25-YEAR PEAK INFLOW 359 CFS
25-YEAR PEAK OUTFLOW 338 CFS
100-YEAR STORM HWL IN POOL 893.82 FT
100-YEAR PEAK INFLOW 515 CFS
100-YEAR PEAK OUTFLOW 496 CFS
WETLAND ELEV INCREMENTAL CUMULATIVE CUMULATIVE
POOL DEPTH AREA VOLUME VOLUME
(FT) (FT) (FT2
) (FT3
) (AC-FT)
0.0 891.25 203,400
0.8 892.00 212,400 155,925 3.58
1.0 892.25 215,500 209,413 4.81
1.8 893.00 391,026 436,860 10.03
1.8 893.07 434,251 465,744 10.69
2.0 893.25 577,078 556,764 12.78
2.3 893.50 758,252 723,680 16.61
© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l
KEPLEY, DANNY & SUSAN
KEPLEY, DANNY & SUSANCITY OF AMES
CITY OF AMES
CITY OF AMES
KEPLEY, DANNY & SUSAN
CITY OF AMES
KEPLEY, DANNY & SUSAN
HADE, DAVID &
DELORA JESPERSEN
POUNDS, SIDNEY C
& DIANA J
KEPLEY, DANNY & SUSAN
OLSON, BERNARD DEAN
ROCHE, ALLEN D
OLSON, BERNARD DEAN
MILLEMAN PRAIRIE
FARMS LLC
904 90
PROPOSED EASEMENT BOUNDARY
CONSTRUCTION ACCESS FROM STAGECOACH ROAD
PROPERTY LINES
SPOIL AREA EXTENTS
STAGECOACH ROAD
EXISTING CITY OF
AMES WATER MAIN
FEMA REGULATORY FLOODWAY BOUNDARY
FEMA NFHL 1% ANNUAL CHANCE FLOOD HAZARD
FEMA NFHL 0.2% ANNUAL CHANCE FLOOD HAZARD
NATURAL OVERFLOW 893.07
EXISTING TILE INTAKE
W
ATER JET EXISTING TILE M
AIN 526 LF
NORMAL POOL (892.25)
100-YEAR HWL (893.82)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 891.25
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
A0
3.
dw g 9/
/2
8:
:3
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
A.03
SITE OVERVIEW
R
FEETSCALE
0 100 200
HORZ.
l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l
PRESERVE EXISTING UTILITY POLE
PRESERVE EXISTING CITY
OF AMES WATER MAIN
COMPLETELY REMOVE EXISTING TILE FOR 50 FT
REMOVE EXISTING TILE
MIN. 5 FT REMOVED EVERY 50 FT
MAY CRUSH IN PLACE IF CLAY
893894
894894
898898
896896
895895895
89389389
896896896897
896896
894894
EXISTING DD 39 16" TILE
EXISTING DD 39 18" TILE
KEPLEY, DANNY & SUSAN
KEPLEY, DANNY & SUSAN
CITY OF AMES CITY OF AMES
CITY OF AMES
KEPLEY, DANNY
& SUSAN
MILLEMAN PRAIRIE
FARMS LLC
OLSON, BERNARD DEAN
COMPLETELY REMOVE EXISTING TILE FOR 50 FT
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
A0
4.
dw g 9/
/2
8:
:1
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
A.04
EXISTING CONDITIONS & REMOVALS
R
FEETSCALE
0 50 100
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
B0
1.
dw g 9/
/2
8:
:2
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.01
INLET STRUCTURE DETAIL
SEE SUDAS FOR SW-513 DETAILS.
PRECAST STRUCTURE SHALL BE ONE
SECTION OR PROVIDE WATERTIGHT SEAL
BETWEEN SECTIONS.
TOP OF STRUCTURE ELEVATION (SEE PROFILE)
PRECAST OPENING ELEVATION
OPENING THIS SIDE
B.03
" W
AL
L
W
ID
TH
48" WALL WIDTH
6" SUMP
FL ELEV (SEE PROFILE)
SEE SUDAS FOR SW-513 DETAILS
SEE M.02 FOR RIP RAP PLACEMENT
BEDDING PER SUDAS
48" WALL WIDTH
MANHOLE LID
SECTION
MODIFIED SW-513
INLET STRUCTURE
PLAN
MODIFIED SW-513
INLET STRUCTURE
NOT TO SCALENOT TO SCALE
2 LF 12" SCH 40 PVC
12" VALTERRA KNIFE VALVE
OR APPROVED EQUAL
1 LF 12" SCH 40 PVC
WITH FLEXIBLE COUPLER
2 LF 12" SCH 40 PVC
12" VALTERRA KNIFE VALVE
OR APPROVED EQUAL
1 LF 12" SCH 40 PVC
WITH FLEXIBLE COUPLER
12" RCP
12" RCP
VALVE HANDLE WITH EXTENSIONS
PROVIDE 4" OR LARGER SCH 40 PVC
AROUND HANDLE AND EXTENSIONS
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
B0
1.
dw g 9/
/2
8:
:2
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.02
OUTLET STRUCTURE DETAIL
TOP OF STRUCTURE ELEVATION (SEE PROFILE)
A B.01
A
6" SUMP
FL ELEV (SEE PROFILE)
PRECAST OPENING ELEVATION
PROVIDE FLEXIBLE, WATERTIGHT GASKET FOR PIPE OPENINGS
SEE SUDAS FOR SW-513 DETAILS
PRECAST STRUCTURE SHALL BE ONE SECTION OR
PROVIDE WATERTIGHT SEAL BETWEEN SECTIONS.
78" WALL
WIDTH
78" WALL WIDTH
1.25'
SEE SUDAS FOR SW-513 DETAILS
OUTLET PIPE
BEDDING PER SUDAS
78" WALL WIDTH
2 LF 12" DUAL-WALL HDPE
12" HICKENBOTTOM INTAKE
OR APPROVED EQUAL
2 LF 12" DUAL-WALL HDPE
12" HICKENBOTTOM INTAKE OR APPROVED EQUAL
12" 90° ELBOW
EXCAVATED WETLAND POOL
EXCAVATE 1 FT ADDITIONAL AROUND INTAKE
PLACE RIP RAP IN 3-FT DIA. CIRCLE AROUND INTAKE
UNDERLAY WITH GEOTEXTILE (1.5 TN)
PLACE RIP RAP IN 6-FT DIA. CIRCLE AROUND INTAKE
UNDERLAY WITH GEOTEXTILE (1.5 TN)
AGRI DRAIN IN-LINE
WATER LEVEL CONTROL
STRUCTURE OR
APPROVED EQUAL
ATTACH TO CONCRETE
STRUCTURE
AGRI DRAIN IN-LINE WATER LEVEL CONTROL
STRUCTURE OR APPROVED EQUAL
STUB IN 12" PIPE
BACKFILL MIN. 1 FT AROUND
WCS WITH 1" CLEAN ROCK
NORMAL WATER LEVEL
9" INLET OPENING
ON ALL SIDES
6" x 6" CENTER
PIER ON ALL
SIDES
STRUCTURE LID PER SUDAS
FIT WITH SW-604 TYPE 5 CASTING
3 FT
SECTION
MODIFIED SW-513
OUTLET STRUCTURE
PLAN
MODIFIED SW-513
OUTLET STRUCTURE
NOT TO SCALE
NOT TO SCALE
NOTES:
1. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS
STEEL.
2. HICKENBOTTOM INTAKE, WATER LEVEL CONTROL
STRUCTURE, DUAL-WALL HDPE, ELBOW, TRASH GUARD,
CASTING, AND ALL HARDWARE AND APPURTENANCES
SHOWN ON THIS PAGE OR REQUIRED FOR INSTALLATION
ARE SUBSIDIARY TO THE OUTLET STRUCTURE.
18" RCP OUTLET PIPE
OPENINGS FOUR
SIDES WITH
CENTER PIERS
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
B0
1.
dw g 9/
/2
8:
:2
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.03
TRASH GUARD DETAIL
TRASH GUARD FOR WETLAND OUTLET STRUCTURE
48"
SHEET STEEL
SHEET STEEL
SHEET STEEL
90"
GROUND CONTACT
TREATED POST 4"x4"
OUTLET
STRUCTURE
12" MIN
SPACE
BELOW
GUARD
24"
CONCRETE FOOTINGS
MIN 12" DIAMETER
4 FT MIN.
EMBEDMENT
NOTE: TRASH GUARD AND APPURTENANCES ARE TYPICAL FOR ALL SIDES OF OUTLET STRUCTURE. QUANTITIES
AND DIMENSIONS FOR STEEL SHEETS PER SIDE OF STRUCTURE ARE AS FOLLOWS:
1 - STEEL SHEET - 90" x 24" x 3/8" 2 - STEEL SHEETS - 48" x 24" x 3/8"
ANGLE IRON--EITHER WELDED OR BOLTED--ON TOP AND BOTTOM OF EACH SHEET AS BRACE.
BOLT TRASH GUARD ONTO ANGLE IRON ANCHORED TO OUTLET STRUCTURE.
PROVIDE THREE POSTS WITH CONCRETE FOOTINGS ON EACH SIDE
GRADE AS NECESSARY TO ALLOW FLOW OF WATER UNDER TRASH GUARD WITH 12" MINIMUM CLEARANCE.
ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL
NOT TO SCALE
STRUCTURE
OPENING
SEE CONNECTION TO
STRUCTURE DETAIL
GRADE BELOW TRASH GUARD TO
PROVIDE 12" MINIMUM SPACE
BETWEEN BOTTOM OF STEEL AND
TOP OF RIP RAP (TYP. ALL SIDES)
CONCRETE STRUCTURE
SHEET STEEL
4" x 4" x 3/8" ANGLE
3/8" BOLT WITH CONCRETE ANCHOR
BOLTS SHALL BE PLACED IN THE CENTER OF THE WALL (TYP)
TRASH GUARD CONNECTION TO STRUCTURE
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
B0
1.
dw g 9/
/2
8:
:3
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.04
PUMP BASIN & SOLAR ARRAY DETAILS
3.5' 21' 3.5'
Included in kit Included in kit
10.5'
17'
4.5' to 5'
DPC2500
solar drive
Solar + -
Solar disconnect
SOLAR ARRAY SUPPORT INSTALLATION DETAILS
NOTE:SOLAR PANELS SHALL BE INSTALLED IN THE LOCATION SHOWN ON A.03 AND
M.02 WITH A SOUTHWARD ORIENTATION.
SOLAR POWERED PUMP SYSTEM (BID ITEM 18) SHALL INCLUDE THE FOLLOWING:
· SOLAR PANELS
· SOLAR DRIVE
· 3-PHASE, 3 HP AXIAL PUMP (CARRY CP-04 WITH 20° IMPELLER OR APPROVED EQUAL,
PROVIDING 390 GPM AT 12.5 FT TDH)
· FLOAT SWITCH
· MOUNTING CLAMPS FOR CONTROLLER
· SOLAR PANEL MOUNTING KIT
· STEEL PIPE EXTENDERS
· WIRED GENERATOR PLUG
· LIGHTNING & SURGE PROTECTOR
· WIRING FOR PANELS, PUMP, AND CONTROLLER
CONTRACTOR SHALL PROVIDE THE FOLLOWING, SUBSIDIARY TO BID ITEM 20:
· STEEL PIPE FOR MOUNTING
· CONCRETE AND ROCK BEDDING FOR MOUNTING POLES
· PVC DISCHARGE PIPE
· CHECK VALVE
PUMP BASIN (BID ITEM 17) SHALL INCLUDE THE FOLLOWING:
· PUMP BASIN (MODIFIED SW-401, SEE DETAILS)
· STEEL LID WITH STAND
MOUNT PUMP CONTROLLER TO
SOLAR POSTS ABOVE 898.50
SOLAR ARRAY SUPPORT
INSTALLATION DETAILS
NOT TO SCALE
PUMP WIRING DIAGRAM
NOT TO SCALE
15 FT
8 FT
PUMP CONTROLLER AND
SOLAR PANELS SHALL BE
ENTIRELY ABOVE THE
ELEVATION 898.50
60 FT
INSTALL SOLAR DRIVES NEXT TO PUMPS
ON POSTS ABOVE 898.50
PLACE 6" CLEAN 1" ROCK IN BOTTOM OF HOLE
FILL HOLE WITH CONCRETE
MIN. 12" DIAMETER
FLOW
NOT TO SCALE
SW-401 WEIR & PUMP BASIN ELEVATION
EXTERIOR MASTIC &
FABRIC WRAP
ALL JOINTS - 9" WIDE
4'
14'
MIN. 12"
15" RCP
FL EL = 886.15
PAINTED STEEL LID WITH ACCESS HATCH
TOP EL = 895.50
8" PVC PUMP OUTLET
EL = 893.50
EXISTING GROUND
APPROX. EL = 893
NORMAL POOL = 892.25
8" MIN. CLASS I BEDDING MATERIAL
SUMP = 879.50
SUDAS SW-401 STRUCTURE
2 FT
PLACE RIP RAP
SEE M.02
FLOAT ELEVATION
ON OFF
886.20 881.50
INSTALL PUMP CONTROL PANELS
ADJACENT TO PUMP BASIN. MOUNT
ON POSTS ABOVE ELEVATION 896.50.
INSTALL CHECK VALVE
FLEXIBLE WATERTIGHT SEAL
4'
14'
15" RCP
FL EL = 886.15
PAINTED STEEL LID WITH ACCESS HATCH
TOP EL = 895.50
8" PVC PUMP OUTLET
EL = 893.50
8" MIN. CLASS I BEDDING MATERIAL
SUMP = 879.50
SUDAS SW-401 STRUCTURE
FLEXIBLE WATERTIGHT SEALS
NOT TO SCALE
SW-401 WEIR & PUMP BASIN SECTION
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
B0
1.
dw g 9/
/2
8:
:3
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.05
RCP INSTALLATION DETAIL
TRENCH INSTALLATION TYPE 3
COMPLETELY FILL
HAUNCH AREA WITH
GRAVELLY SAND
COMPACT TO 85%
STANDARD PROCTOR
DENSITY.
Do
LOOSELY PLACED UNCOMPACTED
GRAVELLY SAND BEDDING
Do/3
3" MIN.
PIPE SPRINGLINE
GRAVELLY SAND BEDDING SHALL BE CONSISTENT WITH THE GRADATION AND
OTHER CHARACTERISTICS OF STANDARD AASHTO A1 OR A3 SOIL. A
REPRESENTATIVE SAMPLE OF THE MATERIAL AND A GRADATION REPORT OR
SUPPLIER'S CERTIFICATION OF COMPLIANCE SHALL BE SUBMITTED TO THE
ENGINEER FOR APPROVAL PRIOR TO DELIVERY TO SITE. SEE SOIL DATA IN
APPENDIX OF SPECIFICATIONS BOOKLET.
6" TYP
0" MIN MEASURE POINT FOR
MAXIMUM TRENCH WIDTH
TOP OF
PIPE
CRUSHED ROCK MEETING THE GRADATION OF SUDAS CLASS I BEDDING
MATERAL, SPECIFICATION SECTION 3010.2.02.A, MAY BE SUBSTITUTED FOR
THE SAND OR CLAY HAUNCH BACKFILL MATERIAL. NO COMPACTION WILL BE
REQUIRED FOR THE CRUSHED ROCK BEDDING AND BACKFILL. MATERIAL
COSTS SHALL BE INCIDENTAL TO PIPE INSTALLATION.
MODIFIED TRENCH INSTALLATION TYPE 4
COMPLETELY FILL HAUNCH
AREA WITH NON-SATURATED
SILTY CLAY OR CLAY SOIL.
COMPACT TO 85% STANDARD
PROCTOR DENSITY. THERE
ARE NO SPECIFIED MOISTURE
LIMITS.
Do
WHERE TRENCH BOTTOM IN FIRM UNDISTURBED SOIL,
SHAPE TRENCH BASE GROOVE TO MATCH MINIMUM
1/6 OF THE OUTER CIRCUMFERENCE OF THE PIPE.
WHERE THE SHAPED GROOVE CANNOT BE
CONSTRUCTED INTO UNDISTURBED GROUND OR
WHERE EXCESS CUT OCCURS OVER EXCAVATE AND
PLACE MINIMUM 3-INCH THICK COMPACTED GRAVELLY
SAND BEDDING TO RESTORE GRADE SUCH THAT 1/6 OR
MORE OF THE OUTER CIRCUMFERENCE OF THE PIPE IS
BEDDED. THIS MATERIAL AND WORK IS SUBSIDIARY TO
THE INSTALLATION OF THE PIPE. CONTRACTOR MAY
SUBSTITUTE PIPE BEDDING ROCK AS THE BEDDING
MATERIAL. IT ALSO IS SUBSIDIARY.
PIPE SPRINGLINE
6" TYP
0" MIN MEASURE POINT FOR
MAXIMUM TRENCH WIDTH
TOP OF
PIPE
MINIMUM TRENCH WIDTH SHALL BE OUTSIDE DIAMETER OF PIPE PLUS 12" OR
THAT WIDTH WHICH IS REQUIRED FOR COMPACTION, WHICHEVER IS GREATER
WHERE FIRM BASE IS NOT
ENCOUNTERED. OVER
EXCAVATE AS DIRECTED BY
ENGINEER. PLACE CRADLING
ROCK AND BED PIPE IN IT
SUCH THAT 1/6 OR MORE OF
THE OUTER CIRCUMFERENCE
OF THE PIPE IS SUPPORTED.
THIS ROCK IS PAID FOR UNDER
A SEPARATE BID ITEM.
THE CONTRACTOR IS SOLEY RESPONSIBLE FOR THE INSTALLATION OF ALL PIPE ACCORDING TO PLAN REQUIREMENTS.
THE CONTRACTOR'S PARTICIPATION IN AND COMPLIANCE WITH THE FOLLOWING PROCEDURE IS REQUIRED AND WILL
ALLOW FOR FEWER SOIL DENSITY TESTS TO ENSURE PROPER PIPE INSTALLATION.
STEP 1
BEFORE COMMENCING PIPE INSTALLATION, STANDARD SOIL PROCTOR DENSITY TEST RESULTS OF REPRESENTATIVE SAMPLE(S) OF PIPE HAUNCH FILL SHALL BE PROVIDED BY AN INDEPENDENT QUALIFIED SOILS TESTING LAB. THE SELECTION OF THE SAMPLE(S) WILL BE MADE BY THE ENGINEER AND CONTRACTOR (WHEN SPECIFIED).
STEP 2
CONTRACTOR MAY BEGIN EXCAVATING THE MODIFIED TYPE 4 TRENCH
WITH THE REQUIRED SHAPED BOTTOM GROOVE AND PLACE SEVERAL PIPE SECTIONS ONLY WHEN BOTH ENGINEER AND
TESTING LAB TECHNICIAN ARE PRESENT
CONTRACTOR SHALL DEMONSTRATE THE INTENDED METHODS FOR COMPACTING THE FILL FOR THE PIPE HAUNCH AREAS. SOIL DENSITY TESTS SHALL BE TAKEN AT LOCATIONS DESIGNATED BY THE ENGINEER TO CONFIRM THAT THE INTEDNED METHODS FOR FILL AND COMPACTION OF THE PIPE HAUNCH AREAS SATIFIES THE PLAN REQUIREMENTS.
CONTRACTOR SHALL MODIFIY THE INSTALLATION METHODS AND REPEAT STEP 2 UNTIL ACCEPTABLE TESTS RESULTS ARE
ACHIEVED.
STEP 3
CONTRACTOR MAY INSTALL THE NEXT SEVERAL HUNDRED FEET OF PIPE. ENGINEER SHALL DESIGNATE SEVERAL LOCATIONS (APPROXIMATELY 10% OF THE INSTALLED LENGTH) WHERE CONTRACTOR SHALL LEAVE THE PIPE UNBLINDED FOR FURTHER DENSITY TESTS OF THE HAUNCH FILL AREA. ALL DENSITY TESTS MUST MEET PLAN REQUIREMENTS BEFORE
WORK MAY PROCEED FURTHER.
IF DENSITY TESTING DATA CONFIRMS TO THE SATISFACTION OF THE ENGINEER THAT THE CONTRACTOR'S INSTALLATION METHOD WILL PRODUCE CONSISTENT COMPLIANCE WITH PLAN REQUIREMENTS, CONTRACTOR MAY CONTINUE INSTALLATION OF THE PIPE WITH NO ADDITIONAL TESTING REQUIRED. IF NOT, STEPS 2 AND 3 SHALL BE REPEATED UNTIL A RELIABLE, SUCCESSFUL METHOD OF PIPE INSTALLATION THAT PRODUCES SATISFACTORY RESULTS IS ESTABLISHED.
TRENCH WALLS
PLUG DOWNSTREAM
TILE WITH PLASTIC END
PLUG, CONCRETE, OR
AS OTHERWISE
ALLOWED.FLOW FLOW
CUT AND SHAPE END OF P.E.
TILE TO FIT FLUSH WITH INSIDE
OF CONCRETE TILE. GROUT
CONNECTION
FILL TRENCH TO P.E. SPRINGLINE WITH COMPACTED CRUSHED
STONE. WHERE COVER EXCEEDS 8 FEET, COVER CONNECTION
AND EXPOSED P.E. WITH 12 INCHES OF CRUSHED STONE
BEDDING COMPLYING WITH SUDAS SPECIFICATION SECTION
3010.301. BUCKET PRESS & COMPACT EARTH FILL UNIFORMLY
ON BOTH SIDES OF STONE TO RESIST LATERAL MOVEMENT OF
THE STONE.
CONCRETE COLLAR EXCEPTION
CONNECTIONS TO THE PIPE AT BOTH ENDS MAY BE MADE
WITH A MANUFACTURED POLYETHYLENE INTERNAL SNAP
COUPLER INSERTED FULLY INTO THE PIPE. CONCRETE COLLARS
NOT REQUIRED WITH POSITIVE LOCKED CONNECTION OR
WHERE COMPACTED CRUSHED ROCK FULLY SURROUNDS THE
CONNECTION. GAPS AT THE CONNECTIONS SHALL BE COVERED
WITH ENGINEERING FABRIC WRAPPED AROUND THE JOINT.
INSERTA TEE WILL BE CONSIDERED AS ALTERNATE
CONNECTION AT NEW MAIN WITH ENGINEERS PRIOR
APPROVAL AND INSTALLATION PER MANUFACTURERS
RECOMMENDATION.
TYPICAL FIELD TILE CONNECTION
FOR FIELD TILE UP TO 10" DIAMETER
CO
VE
R
USE NON-PERFORATED
CORRUGATED P.E. DRAIN TILE
UNDISTURBED
SOIL
SLIDE CORRUGATED P.E. TILE A
MINIMUM OF 6" OVER END OF
EXISTING TILE. ENCASE JOINT (IF
NOT TIGHT FITTING) IN P.C.
CONCRETE COLLAR, AS SHOWN.
FIELD TILE
A
A
PIPE HAUNCH FILL AND COMPACTION METHOD
PLAN REQUIREMENTS COMPLIANCE VERIFICATION
12"
6"
HAND SHAPE TRENCH FOR P.E.
TILE TO INSURE UNDISTURBED
SOIL SUPPORT LOWER 1/2 OF
TILE PERIMETER OR BED ON
CRUSHED STONE FILL AND
THOROUGHLY TAMP SOIL
ENVELOPE
SECTION A-A
TOP OF SOIL
ENVELOPE
UNDISTURBED
SOIL
CONTRACTOR IS REQUIRED TO PROPERLY AND ADEQUATELY INSTRUCT SUBCONTRACTORS AND/OR SUBSEQUENT PIPE
INSTALLATION WORKERS ON THE PROPER INSTALLATION METHOD.
STEP 4A
SOIL OR TRENCH CONDITION CHANGES
TO VERIFY CONTRACTOR'S COMPLIANCE WITH PLAN REQUIREMENTS UNDER THE CHANGED CONDITIONS, ENGINEER MAY STOP WORK AND REQUIRE ADDITIONAL SOIL PROCTOR TESTS AND/OR SOIL DENSITY TESTS SIMILAR TO STEPS 1 THROUGH
3. THE WORK AND COSTS OF THE FIRST TWO REVERIFICATIONS IS SUBSIDIARY TO THE PIPE INSTALLATION. SUBSEQUENT
VERIFICATIONS WILL BE CONSIDERED EXTRA WORK.
STEP 4B
CONTRACTOR FAILS TO CONSISTENTLY PERFORM INSTALLATION METHOD OR INSTRUCT OTHER INSTALLERS
IF CONTRACTOR FAILS TO CONSISTENTLY PERFORM OR ADEQUATELY INSTRUCT SUBCONTRACTORS AND/OR SUBSEQUENT PIPE INSTALLATION WORKERS ON THE APPROVED INSTALLATION METHOD, ENGINEER MAY STOP WORK AND REQUIRE ADDITIONAL SOIL PROCTOR TESTS AND/OR SOIL DENSITY TESTS SIMILAR TO STEPS 1 THROUGH 3 TO VERIFY CONTRACTOR'S COMPLIANCE WITH PLAN REQUIREMENTS. THE WORK AND COSTS OF ALL VERIFICATIONS UNDER SUCH
CONDITIONS IS SUBSIDIARY TO THE PIPE INSTALLATION.
EXCEPTION
IF CONTRACTOR ELECTS TO SHAPE THE TRENCH BOTTOM SUCH THAT A MINIMUM OF 45% OF THE OUTER CIRCUMFERENCE OF THE PIPE IS FIRMLY BEDDED IN AND CONSISTENTLY SUPPORTED BY UNDISTURBED SOIL, PIPE HAUNCH FILL COMPACTION TESTING WILL NOT BE REQUIRED. THE CONTRACTOR IS REQUIRED TO COMPLY WITH A PROPER INSTALLATION METHOD AND TO FULLY COMPLY WITH THE REQUIREMENTS OF THE VERIFICATION OUTLINED
ABOVE FOR ALL SITUATIONS WHERE THIS EXCEPTION IS NOT MET.
NOT TO SCALE
SOURCE: AMERICAN CONCRETE PIPE ASSOCIATION
CONCRETE PIPE DESIGN MANUAL
NOT TO SCALE
SOURCE: AMERICAN CONCRETE PIPE ASSOCIATION
CONCRETE PIPE DESIGN MANUAL
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
B0
1.
dw g 9/
/2
8:
:4
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.06
CPDT INSTALLATION DETAIL
FLAT BOTTOM TRENCH INSTALLATION
FILL TRENCH TO 6" ABOVE TOP OF PIPE WITH CRUSHED STONE OR GRAVEL
MEETING THE REQUIREMENTS IN TABLE 2. BEDDING MATERIAL SHALL BE
INCIDENTAL TO THE PIPE INSTALLATION.
PREFFERED TRENCH INSTALLATION BOTTOM
CORRUGATED POLYETHYLENE DRAINAGE TUBING
MATERIAL & INSTALLATION NOTES
NOT TO SCALE
SOURCE: ASTM F449
TRAPEZOIDAL GROOVE, "V" GROOVE, & CIRCULAR GROOVE
NOT TO SCALE
SOURCE: ASTM F449
6" MIN FOR
OPEN TRENCH
INSTALLATION
R
6" M
IN
A B G
0.
5R
0.
R
TRENCH WIDTH MEASURED
AT TOP OF PIPE
90° "V" GROOVE
90°
THE CIRCULAR GROOVE SHALL BE A
MINIMUM 0.35R DEEP AND SHALL
MATCH THE OUTSIDE CURVE
SHAPE OF THE DEFLECTED CPDT.
THE TRAPEZOIDAL GROOVE SHALL
BE SHAPED AND ADJUSTED SUCH
THAT POINTS A, B, & C WILL TOUCH
THE UNDEFLECTED CPDT FOR EACH
SIZE INSTALLED.
TRAPEZOIDAL GROOVE
CIRCULAR GROOVE
UNDISTURBED SOIL
UNDISTURBED SOIL
TRENCH WIDTH MEASURED
AT TOP OF PIPE
4" M
IN
SEE TABLE 2 FOR
BEDDING MATERIAL
NOTE: THIS IS AN ALLOWED ALTERNATIVE INSTALLATION FOR CPDT
1. ALL CPDT AND CONNECTORS FURNISHED SHALL BE IN COMPLIANCE WITH MATERIAL STANDARDS ASTM F405 AND F667, AS
APPLICABLE, AND SHALL BE CLASSIFIED AS HEAVY-DUTY UNDER THOSE STANDARDS.
2. EXCEPT MODIFIED HEREIN OR OTHERWISE APPROVED BY ENGINEER, ALL CPDT SHALL BE INSTALLED IN COMPLIANCE WITH THE
ASTM 449 STANDARD PRACTICE.
3. FOR PIPES 6” DIAMETER AND SMALLER A 90° V GROOVE BOTTOM MAY BE USED, FOR ALL LARGER PIPE A TRAPEZOIDAL BOTTOM OR A CIRCULAR BOTTOM CONFORMING TO THE OUTSIDE DIAMETER OF THE PIPE SHALL BE USED. PRIOR TO THE INSTALLATION OF CPDT, CONTRACTOR MUST PROVE TO ENGINEER THAT THE INSTALLATION REQUIREMENTS, INCLUDING THE
SHAPE OF THE TRENCH BOTTOM, WILL BE ACCOMPLISHED.
4. WHERE TRENCH BOTTOM IS IN FIRM UNDISTURBED SOIL, SHAPE TRENCH BASE GROOVE. WHERE EXCESS CUT OCCURS, OVEREXCAVATE AND PLACE MINIMUM THREE (3) INCH THICK, GRAVELLY SAND BEDDING TO RESTORE GRADE. THIS BEDDING SHALL MEET THAT REQUIRED FOR TRENCH INSTALLATION TYPE 3 ON PLAN SHEET B.02. THIS MATERIAL AND WORK SHALL BE INCIDENTAL TO THE INSTALLATION OF THE PIPE. CONTRACTOR MAY SUBSTITUTE PIPE BEDDING ROCK AS THE BEDDING
MATERIAL.
5. NATIVE SOILS MAY BE USED AS BACKFILL MATERIAL UNLESS UNSTABLE TRENCH CONDITIONS PREVENT THE TRENCH BOTTOM HOLDING THE SHAPED GROOVE. IF TRENCH BOTTOM WILL NOT HOLD GROOVE SHAPE CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY. A FLAT BOTTOM TRENCH INSTALLATION WILL THEN BE ASSUMED. THE REQUIRED BEDDING MATERIAL SHALL BE
INCIDENTAL TO THE INSTALLATION OF THE PIPE.
6. MINIMUM TRENCH WIDTH IS PIPE OUTSIDE DIAMETER PLUS FOUR (4) INCHES FOR PLOWED INSTALLATION AND PIPE OUTSIDE
DIAMETER PLUS TWELVE (12) INCHES FOR OPEN TRENCH INSTALLATION.
7. ALL LATERAL CONNECTIONS, ELBOWS, TEES, ALIGNMENT CURVES, START HOLES AND ALL PORTIONS OF THE TRENCH NOT MEETING THE GROOVED TRENCH INSTALLATION REQUIREMENTS SHALL BE FILLED TO A MINIMUM OF SIX (6) INCH COVER OVER THE PIPE WITH GRADED CRUSHED STONE OR GRAVEL AS SHOWN ON TABLE 2 OF THIS SHEET. BEDDING MATERIAL SHALL BE
INCIDENTAL TO THE INSTALLATION OF THE PIPE.
8. MANUFACTURER'S ENDCAPS SHALL BE INSTALLED AT THE TERMINATION OF EACH LINE UNLESS A CONNECTION TO AN EXISTING
DRAIN IS MADE.
9. WITH THE INSTALLATION OF THE FIRST REACH OF CPDT ON THE PROJECT, CONTRACTOR IS REQUIRED TO WORK WITH THE
ENGINEER TO CHECK AND CONFIRM THAT THE PIPE STRETCH, IF ANY, DOES NOT EXCEED 5%.
10. ALIGNMENT TURNS MAYBE MADE USING EITHER A MANUFACTURED FITTING OR CURVING THE LINE WITH A 25' MINIMUM
RADIUS.
R25'
PI
X °
PT
PT
Table 1 Maximum Allowable Buried Depth to Flowline of CPDT
Nominal Pipe Diameter (IN)
Pipe Quality
(ASTM)
Trench Width at Top of the Pipe (FT)
12" 18" 24" 30" or Greater
Standard 13 7 5.5 5
Heavy-duty Any 10 7 6
Standard 10 7 5.5 5
Heavy-duty Any 9.5 6.5 6
Standard 10 7 5.5 5
Heavy-duty Any 10 7 6
10 Heavy-duty ... 9 7 6 12 Heavy-duty ... 9 7 6 15 Heavy-duty ... ... 7 6
Table 2 Acceptable Bedding Material and Compaction Requirements
Description Percentage Passing Sieve Sizes Minimum
Standard Density (%)
Maximum Compaction Layer Height
(IN.)1" 3/4" No. 4
Crushed Stone Crushed Gravel* 100% > 95% < 5% Dumped 18
* Class 1 Bedding Material Per SUDAS 3010.202A is an Allowable Substitute
DEGREES Δ DELTA
20° 4.41 30° 6.7 45° 10.36 60° 14.43 70° 17.51 80° 20.98 90° 25
DISTRICT TILE MAIN SHALL BE
INSTALLED WITH A FLAT BOTTOM
TRENCH AND BEDDED AS SHOWN.
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
C0
1.
dw g 9/
/2
8:
:5
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
C.01
ESTIMATED QUANTITIES
Bid Item Description Specifications
Plan No.
Estimated Quantities
No. Page Quantity Unit
1 Site Stripping & Preparation IA CS-001 3 A.02 1 LS
2 Crop Damage IA CS-001 3 - 0 AC
3 Buffer Seeding IA CS-006 7 K.01 26.6 AC
4 Structure Seeding IA CS-006 7 K.01 0.4 AC
5 Mobilization and Demobilization IA CS-008 11 - 1 LS
6 Drain Tile Investigation and Removal IA CS-009 14 A.04 4 HR
7 Excavation (General) IA CS-021 20 D.01 13571 CY
8 Earthfill (General) IA CS-023 22 D.01, M.03 334 CY
9 Topsoil Stripping, Stockpiling, & Placement IA CS-026 26 D.01 344 CY
10 12" Dia. Reinforced Concrete Pipe IA CS-031 28 B.04, M.03 168 LF
11 15" Dia. Reinforced Concrete Pipe IA CS-031 28 B.04, M.02 35 LF
12 18" Dia. Reinforced Concrete Pipe IA CS-031 28 B.04, M.03 151 LF
13 12" Reinforced Concrete Apron, Footing, Bar Guard IA CS-031 28 M.03 1 EA
14 Modified SW-513 Inlet Structure (48" x 48") IA CS-031 28 B.02, M.03 1 EA
15 Modified SW-513 Outlet Structure (48" x 48") IA CS-031 28 B.01, M.03 1 EA
16 SW-401 Concrete Manhole Structure IA CS-031 28 M.01-M.02 2 EA
17 SW-401 Pump Basin IA CS-031 28 B.03, M.02 1 EA
18 Solar Pump System IA CS-031 28 B.03, M.03 1 EA
19 6" Dia. Corrugated HDPE Pipe (Dual-Wall, Non-Perforated) IA CS-046 36 B.05, M.02 662 LF
20 18" Dia. Corrugated HDPE Pipe (Dual-Wall, Non-Perforated) IA CS-046 36 B.05, M.01 1150 LF
21 Rip Rap (Class E) IA CS-061 40 M.02-M.03 28.4 TN
22 Clean Existing Tile Main (526 LF) IA CS-046 1 LS
900900
894894
898898
896896
896896
5 894 l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l
100-YEAR HWL = 893.50
4 FT WIDE COVER BERM
TOP ELEV. 898.50
GRADE AT 6:1 SLOPE
SPOIL AREA EXTENTS
30 FT WIDE INLET CHANNEL
ELEV. 891.25
GRADE AT 4:1 SLOPE
EXCAVATE POOL TO 891.25
GRADE AT 4:1 SLOPE
EXCAVATE POOL TO 891.25
GRADE AT 4:1 SLOPE
PRESERVE EXISTING
UTILITY POLE
PROTECT EXISTING CITY
OF AMES WATER MAIN
SEDIMENT FOREBAY
ELEV. 888.25
GRADE AT 2.5:1 SLOPE
DIVERSION BERM
10 FT TOP, 4:1 SIDES
TOP ELEV = 891.75
DIVERSION BERM
10 FT TOP, 4:1 SIDES
TOP ELEV = 891.75
EXCAVATE POOL TO 891.25
894896897898899
10.00% 2.16%
.0
8%
10.16%
SPOIL PILE
NORMAL POOL (892.50)
100-YEAR HWL (893.82)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 891.50
MINIMUM 6" TOPSOIL LAYER
LEGEND
l l l l l l l l l l l l l l
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
D0
1.
dw g 9/
/2
8:
:2
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
D.01
GRADING OVERVIEW
R
FEETSCALE
0 50 100
HORZ.
1" = 200'
EARTHWORK QUANTITIES
EXCAVATION (POOL, INLET CHANNEL, SEDIMENT FOREBAY): 13,570 CY
EARTHFILL (COVER BERM, DIVERSION BERMS): 334 CY
SPOIL (6" SPREAD OVER AREAS SHOWN): 13,236 CY
SEED COVER BERM
STRUCTURE SEEDING
SEED DISTURBED AREAS TO
1 FT BELOW NORMAL POOL
STRUCTURE SEEDING
SEED DISTURBED AREAS TO
1 FT BELOW NORMAL POOL
BUFFER SEEDING
SEED DISTURBED AREAS TO
1 FT BELOW NORMAL POOL
BUFFER SEEDING
SEED BUFFER AREA TO
EASEMENT BOUNDARY
BUFFER SEEDING
SEED BUFFER AREA TO
EASEMENT BOUNDARY
BUFFER SEEDING
SEED FINAL SPOIL AREA
BUFFER SEEDING
SEEDING AREAS
BUFFER SEEDING 26.6 AC
STRUCTURE SEEDING 0.4 AC
SPOIL AREA EXTENTS
894 893
6 89
7 89
DO NOT SEED POOL
SEED BUFFER AREA TO
EASEMENT BOUNDARY
BUFFER SEEDING
SPOIL AREA EXTENTS
NORMAL POOL (892.25)
100-YEAR HWL (893.82)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 891.25
STRUCTURE SEEDING
BUFFER SEEDING
FLOW PATH THROUGH WETLAND
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
K0
1.
dw g 9/
/2
8:
:4
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
K.01
SEEDING OVERVIEW
R
FEETSCALE
0 50 100
EXISTING 16" C
ONCRETE TILE
TOP = 889.04
FL =
887.71
0+00 1+00 1+50
BP
: 0
+0 0.
EP
: 1
+5 0.
RIP RAP
11 FT x 10 FT
8.7 TONS
SOLAR PANEL LOCATION
INSTALL ABOVE 898.50
(STA 0+58)
SW-401 (48in)
CASTING: SW-602 TYPE E
TOP = 895.83
FL IN = 887.69 (16" NW)
FL OUT = 887.69 (18" SE)
FL OUT = 886.18 (15" SW)
PUMP BASIN (STA 1+17)
MODIFIED SW-401 (48")
SEE B.03
TOP = 895.50
FL IN = 885.81 (15" NE)
EXISTING DD 39 16" TILE
892894
-0+25 0+00 1+00 2+00
4.
4.
3.
3.
3.
2.
2.
6.
6.
5.
-0.50%
STA: 0+42.34
EL: 886.18
STA: 1+17.50
EL: 885.81
75' - 15" RCP @ 0.50%
75 LF - 15" RCP
@ 0.50% 1742
PU
M
P
BA
SI
N
(S
TA
+1
7) M
O
DI
FI
ED
S W
-4
(4 8"
SE
E B.
TO
P
5.
FL
IN
.8
(1 5"
N E)
EXISTING SURFACE NWL = 892.25
EXCAVATED POOL
(S
TA
+5
0)
SW
-4
(4 8i n)
CA
ST
IN
G:
S
W -6
T
YP
E
E
TO
P
5.
FL
IN
.6
(1 6"
N W
FL
O U
T
7.
(1
8" S
E)
FL
O U
T
6.
(1
5" S
W
PROVIDE MARKER FLAG
NORMAL POOL (892.25)
100-YEAR HWL (893.82)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 891.25
STRUCTURE SEEDING
LEGEND
EXISTING 16" CONCRETE TILE
TOP = 887.77
FL = 886.44
0+00 1+00 2+00
BP
: 0
+0 0.
EP
: 2
+0 0.
RIP RAPSEE B.01
0.6 TONS>> >> >> >> >>
OUTLET STRUCTURE (STA 0+25)
MODIFIED SW-513
SEE B.01
TOP = 893.50
OPENING = 892.25
FL OUT = 887.96 (18" SE)
(STA 1+76)
SW-401 (72in)
CASTING: SW-602 TYPE E
TOP = 894.70
FL IN = 886.52 (18" NW)
FL IN = 886.52 (18" N)
FL OUT = 886.52 (18" SE)
-0+50 0+00 1+00 2+00 2+50
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
O U
TL
ET
S
TR
U
CT
U
RE
(S
TA
+2
5) M
O
DI
FI
ED
S W
-5
SE
E
B.
TO
P
3.
O
PE
N
IN
G
2.
FL
O U
T
7.
(1
8" S
E)
131' - 18" RCP @ 1.10%
131 LF - 18" RCP
@ 1.10% 5625
-1.10%
STA: 0+25.00
EL: 887.96 STA: 1+55.77
EL: 886.52
EXISTING SURFACE
EXISTING 18" DD 39 TILE
NWL = 892.25
EXCAVATED POOL
ST
A 1+
SW
-4
(7
2i n)
CA
ST
IN
G:
S W
-6
T
YP
E E
TO
P
4.
FL
IN
.5
(1
8" N
W
FL
IN
.5
(1
8" N
FL
O U
T
6.
(1
8" S
E)
PROVIDE MARKER FLAG
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
M
.d w g
9/
/2
8:
:0
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
FEETSCALE
0 25 50
HORZ.
FEETSCALE
0 5 10
VERT. M.01
PLAN & PROFILE - PUMP INLET PIPE & OUTLET PIPE
R
PUMP INLET PIPE
R
OUTLET PIPE
CLEAN PIPE DOWNSTREAM OF CONNECTION
-0+50 0+00 1+00 2+00 2+50
9.
6.
7.
6.
5.
5.
5.
5.
5.
5.
3.
3.
3.
3.
3.
3.
-0.30%
STA: 0+27.96
EL: 894.00
STA: 1+92.69
EL: 893.50
IN
LE
T
ST
RU
CT
U
RE
(S
TA
+2
8) M
O
DI
FI
ED
S W
-5
TO
P
7.
O
PE
N
IN
G
6.
FL
O U
T
4.
(1
2" W
ST
A
1+
" A
PR
O
N , F
O O
TI
N
G, B
AR
G
U
AR
D
FL
IN
.5
(1 2"
E
165' - 12" RCP @ 0.30%
165 LF - 12" RCP
@ 0.30% 9328
6:1EXISTING SURFACE
COVER BERM
TOP ELEV. 898.50
NWL = 892.25
EXCAVATED SEDIMENT FOREBAY
0+00
1+00
2+00 2+25
BP
: 0
+0 0.
EP
: 2
+2 5.
00RIP RAP
10.5 TONS
TOP OF RIP RAP = 895.50
INLET STRUCTURE (STA 0+28)
MODIFIED SW-513
TOP = 897.25
OPENING = 896.00
FL OUT = 894.00 (12" W)
STA 1+93
12" APRON, FOOTING, BAR GUARD
FL IN = 893.50 (12" E)
COVER BERM
TOP ELEV. 898.50
RIP RAP
10 FT x 11 FT
8.7 TONS
NORMAL POOL (892.25)
100-YEAR HWL (893.82)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 891.25
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
M
.d w g
9/
/2
8:
:0
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
FEETSCALE
0 25 50
HORZ.
FEETSCALE
0 5 10
VERT. M.02
PLAN & PROFILE - DITCH INLET PIPE
DITCH INLET PIPE
-1+25 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 13+75
4.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
2.
2.
2.
2.
2.
4.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
2.
2.
2.
2.
2.
-0.09%
STA: 0+65.87
EL: 887.46 STA: 12+26.30
EL: 886.39
(S
TA
+5
0)
SW
-4
(4 8i n)
CA
ST
IN
G:
S
W -6
T
YP
E
E
TO
P
5.
FL
IN
.6
(1 6"
N W
FL
O U
T
7.
(1
8" S
E)
FL
O U
T
6.
(1
5" S
W
ST
A
+2 2)
SW
-4
(7
2i n)
CA
ST
IN
G:
S W
-6
T
YP
E E
TO
P
4.
FL
IN
.5
(1
8" N
W
FL
IN
.5
(1
8" N
FL
O U
T
6.
(1
8" S
E)
ST
A
8+
° E
LB
O
W
FL
IN
.8
(1 8"
N W
FL
O U
T
6.
(1
8" S
30 FT INLET CHANNEL
BOTTOM ELEV. 891.25
EXISTING SURFACE
EXISTING DD 39 16" TILE
EXISTING DD 39 18" TILE
NWL = 892.25
DRAINAGE DISTRICT TILE CAPACITIES
EXISTING: 16" @ 0.1% = 2.10 CFS
PROPOSED: 18" @ 0.09% = 3.41 CFS
l l l l l l l l
0+00
1+00
2+00
3+00
4+00
5+00
6+00
7+00
8+00
9+00
10+00
11+00
11+75BP
: 0
+0 0.
PI
: 8
+2 8.
EP
: 1
1+
.0
0+00
1+00
2+00
3+00
4+00
5+00
6+00
7+00
8+00
9+00
10+00
11+00
11+75BP
: 0
+0 0.
PI
: 8
+2 8.
EP
: 1
1+
.0
(STA 0+50)
SW-401 (48in)
CASTING: SW-602 TYPE E
TOP = 895.83
FL IN = 887.69 (16" NW)
FL OUT = 887.69 (18" SE)
FL OUT = 886.18 (15" SW)
(STA 11+22)
SW-401 (72in)
CASTING: SW-602 TYPE E
TOP = 894.70
FL IN = 886.52 (18" NW)
FL IN = 886.52 (18" N)
FL OUT = 886.52 (18" SE)
STA 8+29
30° ELBOW
FL IN = 886.84 (18" NW)
FL OUT = 886.84 (18" S)
898898
892 893
896896
RING TILE
SEE M.02
OUTLET PIPE
SEE M.01
PUMPED INLET PIPE
SEE M.02
EXISTING DD 39 16" TILE
EXISTING DD 39 18" TILE
NORMAL POOL (892.25)
100-YEAR HWL (893.82)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 891.25
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
M
.d w g
9/
/2
8:
:3
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
FEETSCALE
0 50 100
HORZ.
FEETSCALE
0 5 10
VERT. M.03
PLAN & PROFILE - TILE RE-LAY
TILE RE-LAY
CLEAN PIPE DOWNSTREAM OF CONNECTION
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 7+50
5.
5.
5.
5.
5.
5.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
3.
3.
3.
3.
3.
3.
3.
3.
3.
7.
7.
7.
7.
7.
7.
7.
7.
7.
7.
7.
7.
7.
8.
8.
8.
8.
8.
8.
-0.10% 0.10%
STA: 3+00.00
EL: 887.94
STA: 4+24.67
EL: 887.81
STA: 7+50.00
EL: 888.14
125' - 6" HDPE @ 0.10%
125 LF - 6" DUAL-WALL
NON-PERF. HDPE
@ 0.10% 2500
ST
A 3+
CA
P
EN
D O
F
PI
PE
FL
O U
T
7.
(6
" W
ST
A
4+
TE
E
IN
TO
E
XI
ST
IN
G
TI
LE
FL
IN
.8
(6 " E
FL
IN
.8
(6 " W
EXISTING GROUND SURFACE
325' - 6" HDPE @ 0.10%
325 LF - 6" DUAL-WALL
NON-PERF. HDPE
@ 0.10%25 50
ST
A
7+
TI
E
IN
E
XI
ST
IN
G
TI
LE
FL
O
U T
8.
(6 " E
EXISTING DD 39 16" TILE
EXISTING 16" CONCRETE TILE
TOP = 889.04
FL = 887.71
REMOVE EXISTING INTAKE
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00
BP
: 0
+0 0.
STA 3+00
CAP END OF PIPE
FL OUT = 887.94 (6" W)
STA 4+25
TEE INTO EXISTING TILE
FL IN = 887.81 (6" E)
FL IN = 887.81 (6" W)
(STA 3+96)
SW-401 (48in)
CASTING: SW-602 TYPE E
TOP = 895.83
FL IN = 887.69 (16" NW)
FL OUT = 887.69 (18" SE)
FL OUT = 886.18 (15" SW)
895 894
EXISTING DD 39 16" TILE
NORMAL POOL (892.25)
100-YEAR HWL (893.82)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 891.25
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
M
.d w g
9/
/2
8:
:4
AM
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJECT NO. STO842436B
BCS
NVD
JPR
25X.138711.000
1.1 IDALS REVISIONS 02-09-2026
1.2 PERMIT PLANS 05-20-2026
1.3 PERMIT PLANS REV. 2 09-15-2026
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
FEETSCALE
0 25 50
HORZ.
FEETSCALE
0 5 10
VERT. M.04
PLAN & PROFILE - RING TILE
RING TILE
| Sheets and Views |
| A.01 TITLE SHEET |
| A.02 PLAN OVERVIEW |
| A.03 SITE OVERVIEW |
| A.04 EXISTING CONDITIONS & REMOVALS |
| B.01 INLET STRUCTURE DETAIL |
| B.02 OUTLET STRUCTURE DETAIL |
| B.03 TRASH GUARD DETAIL |
| B.04 PUMP BASIN & SOLAR ARRAY DETAILS |
| B.05 RCP INSTALLATION DETAIL |
| B.06 CPDT INSTALLATION DETAIL |
| C.01 ESTIMATED QUANTITIES |
| D.01 GRADING OVERVIEW |
| K.01 SEEDING OVERVIEW |
| M.01 PLAN & PROFILE - PUMP INLET PIPE & OUTLET PIPE |
| M.02 PLAN & PROFILE - DITCH INLET PIPE |
| M.03 PLAN & PROFILE - TILE RE-LAY |
| M.04 PLAN & PROFILE - RING TILE |
| 2026-09-16T09:11:00-0500 | |
| Brandon Short |
File details come from the government source that posted it. Updated .