This is a Pre-Demolition Asbestos-Containing Building Materials (ACBM) Inspection Report prepared by Farmer Environmental Group, LLC for the City of McKinney, Texas, regarding the Development Services Building located at 220 N. Kentucky Street. The inspection was conducted on December 9 and 10, 2025, by TDSHS-licensed Asbestos Inspectors to identify asbestos-containing products and assess their impact on planned demolition activities in accordance with Senate Bill 509 requirements. The scope included all suspect asbestos-containing interior, exterior, and roofing materials. One hundred sixty-nine (169) bulk material samples were collected and analyzed by Moody Labs, LLC using Polarized Light Microscopy (PLM) coupled with dispersion staining. The inspection identified three asbestos-containing products: tan vinyl cove base (2% chrysotile, 16 SF, Category II Non-Friable), residual roofing tar (10% chrysotile, 35 SF, Category I Non-Friable), and roof seam tar (10% chrysotile, 55 SF, Category I Non-Friable). An additional fifty-eight (58) materials tested negative for asbestos content.

The report recommends that only licensed Asbestos Abatement Contractors remove, repair, enclose, or encapsulate identified asbestos-containing materials under the monitoring of a licensed Asbestos Consultant. The Texas Department of State Health Services must be notified at least ten (10) working days before initiating abatement activities using TDSHS forms. All friable and non-friable ACBM with potential to become friable during abatement must be removed prior to renovation or demolition activities in compliance with National Emission Standards for Hazardous Air Pollutants (NESHAP) regulations (EPA 40 CFR 61, Subpart M). The report notes that building owners retain liability for asbestos materials throughout transport and burial in EPA-approved landfills. Additional bulk samples must be collected from previously concealed materials revealed during demolition activities. The report cautions that despite the thoroughness of the inspection, some asbestos-containing areas may have been overlooked or remained inaccessible without damaging existing coverings, and conditions are subject to change.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

January 9, 2026

Ms. Patricia Jackson, P.E., RAS Facilities Construction Manager City of McKinney 1400 S. College Street McKinney, Texas 75069

RE: Pre-Demolition Asbestos-Containing Building Materials Inspection Development Services Building

220 N. Kentucky Street – McKinney, Texas 75069 Farmer Environmental Group Project No. 2040.52

Ms. Jackson:

Enclosed is Farmer Environmental Group’s Asbestos-Containing Building Materials Inspection Report for the Development Services Building located at 220 N. Kentucky Street in McKinney, Texas.

Farmer Environmental Group appreciates this opportunity to provide asbestos consulting services to the City of McKinney. We have enjoyed working with you on this project and look forward to meeting your needs in the future. Should any questions arise concerning this report, please contact us at (972) 390-8014.

Sincerely, John Purcell Tyler Godby TDSHS Asbestos Inspector #603293 TDSHS Asbestos Inspector #604046

Principal Review:

Michael St. Clair Robert Alexander, Chief Operating Officer TDSHS Asbestos Inspector #604252 TDSHS Individual Asbestos Consultant #105196 Farmer Environmental Group, LLC

APPENDICES:

Appendix I: Bulk Sample Analysis Appendix II: Bulk Sample and Material Location Drawings Appendix III: Texas Department of State Health Services Licenses

ASBESTOS-CONTAINING BUILDING MATERIALS

INSPECTION REPORT

Development Services Building

220 N. Kentucky Street McKinney, Texas 75069

January 9, 2026

I. INTRODUCTION

Farmer Environmental Group, LLC (Farmer) inspected the Development Services Building (the Site) located at 220 N. Kentucky Street in McKinney, Texas for asbestos-containing building materials (ACBM) on December 9 & 10, 2025. Texas Department of State Health Services (TDSHS)-licensed Asbestos Inspectors John Purcell (license #603293), Tyler Godby (license #604046), and Michael St. Clair (license #604252) conducted this inspection under an agreement between Farmer and the City of McKinney. The scope of work included all suspect asbestos-containing interior, exterior, & roofing materials in advance of planned demolition of the structure.

The purpose of the inspection was threefold: 1) determine locations and conditions of asbestos-containing products used at the Site; 2) determine the impact these materials will have on planned renovation activities; and 3) assist the City of McKinney and/or their client in obtaining the necessary building permit with the City of McKinney in accordance with Senate Bill 509.

II. SUMMARY OF FINDINGS & RECOMMENDATIONS

Based on the laboratory analysis of the bulk samples collected, the following asbestos products were identified at the Site:

• Vinyl cove base

• Residual roofing tar

• Roof seam tar

It should be noted that the inspector made reasonable attempts to determine whether suspect materials were present beneath existing materials. However, suspect materials may be present under existing materials that were inaccessible without significantly damaging existing coverings.

Farmer has extensive experience with commercial structures that have been abated prior to demolition or renovation projects. Because commercial renovations occur from time to time, existing asbestos-containing materials are occasionally found in sporadic areas under new materials.

Although representative samples of existing materials were collected and analyzed for asbestos content during the asbestos inspection, an asbestos inspector cannot confirm that no suspect materials exist in other areas without removing all of the current existing materials. Therefore, demolition of existing materials should proceed with caution. If suspect materials not identified in this report are uncovered during the performance of any demolition or renovation activities, material demolition activities should cease until samples of the suspect materials are analyzed for asbestos content.

Additional bulk samples should be collected from previously concealed materials that may be revealed during the performance of any demolition or renovation activities, or from materials outside the original inspection scope of work. "Suspect" material includes any material not made of metal, glass, rubber, plastic, fiberglass, or wood ; examples include those materials serving as a sprayed-on or troweled-on acoustic or fireproofing surface; floor and ceiling tiles; cement asbestos panels, siding or shingles; thermal insulation or any material associated with mechanical systems;

or any binding agent such as tar sealant, mastic adhesive, roofing tar, caulking, etc. TDSHS regulations require bulk samples in public buildings be collected by a licensed asbestos inspector or individual asbestos consultant.

III. SAMPLE RESULTS

ASBESTOS AND NON-ASBESTOS PRODUCTS IN THE FACILITY

The PLM Report in Appendix I shows the results of PLM analysis for bulk samples collected at the Site, as required under Task 1 above. The PLM Report shows the room or area in which the sample was collected and provides a description of the sampled material. Site drawings are included in Appendix II.

Any product containing greater than 1% fibrous asbestos, when analyzed by PLM, is considered a potential hazard by the United States Environmental Protection Agency (US EPA). However, it should be noted that the Texas Asbestos Health Protection Rules (TAHPR) lowered the threshold level in Texas from ‘greater than one percent asbestos’ (current US EPA guideline) to ‘one percent or greater’ as of July 8, 2021. PLM is the US EPA-recognized method for determining fibrous bulk asbestos content. Additionally, the US EPA indicates that further analysis by point counting be performed to confirm asbestos content for friable materials found to contain less than ten percent asbestos by visual area estimation. Point counting analysis may be omitted if the material is assumed to contain equal to or more than one percent asbestos and is then handled accordingly.

All samples collected by Farmer were analyzed by Moody Labs, LLC, a TDSHS-licensed and National Voluntary Laboratory Accreditation Program (NVLAP)-accredited laboratory located in Farmers Branch, Texas. The samples were analyzed by PLM coupled with dispersion staining, in general accordance with US EPA-600/R-93/116. Utilizing this procedure, the various asbestos minerals (chrysotile, amosite, crocidolite, actinolite, tremolite, and anthophyllite) can be determined by the microscopist.

Sample analysis reported as "None Detected" should be interpreted as meaning no asbestos was observed in the suspect material above the reliable limit of detection, (Less Than 1% by visual estimation) for the PLM method.

Sample analysis reported as "Not Analyzed – Positive Stop" should be interpreted as meaning a sample of the same homogeneous material was analyzed with an asbestos content equal to or greater than 1%. Further analysis is therefore considered unnecessary.

The US EPA's National Emission Standards for Hazardous Air Pollutants (NESHAP) asbestos regulation (US EPA 40 CFR 61, Subpart M) classifies asbestos-containing materials into the following three categories:

Category I Category I non-friable ACM refers to asbestos-containing packing, gaskets resilient floor covering, and asphalt roofing products containing more than 1% asbestos that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

Category II Category II non-friable ACM is any non-friable material that is not Category I and contains greater than 1% asbestos that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

RACM Regulated Asbestos-Containing Materials (RACM) is a friable (reducible to powder by hand pressure) manufactured ACM; or a Category I non-friable ACM that has become friable; or a Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading; or Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations. RACM should be removed prior to renovation or demolition activities.

RACM is further defined by NESHAP as:

a) Friable asbestos material;

b) Category I nonfriable ACM that has become friable;

c) Category I nonfriable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or

d) Category II nonfriable ACM that has become crumbled, pulverized, or reduced to powder or has a high probability of becoming crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations regulated by NESHAP asbestos regulation (US EPA 40 CFR 61, Subpart M).

The following Category I Non-Friable asbestos product (material not reducible to a powder or dust form under normal hand pressure) was identified at the Site:

Table 2 – Category 1 Non-Friable ACM

Material Description Estimated Quantity

Asbestos Content Location / Condition

Residual Roofing Tar 35 SF 10% Chrysotile Parapet / Good

Roof Seam Tar 55 SF 10% Chrysotile Parapet / Good

The following Category II Non-Friable asbestos product (material not reducible to a powder or dust form under normal hand pressure) was identified at the Site:

Table 3 – Category 2 Non-Friable ACM

Material Description Estimated Quantity

Asbestos Content Location / Condition

Tan Vinyl Cove Base 16 SF 2% Chrysotile Fire Riser Room / Good

The following products were tested and found to contain no asbestos when analyzed by PLM:

1. Black ceramic wall tile, grout, & white adhesive

2. Millwork caulk

3. Black millwork glue

4. Glass wall tile mortar

5. Textured wall concrete

6. Beige HVAC duct mastic

7. CMU block, filler, & mortar

8. Gray 6” x 6” ceramic floor tile, grout, & mortar

9. White 4” x 4” ceramic wall tile, grout, & white adhesive

10. Gray ceramic wall tile base, grout, & white adhesive

11. Yellow carpet mastic

12. Drywall, smooth texture, & associated joint compound

13. Drywall, wall covering, & associated joint compound

14. Terrazzo flooring & tan mastic

15. Plaster with texture/paint

16. Interior brick & mortar

17. Plaster with sandy texture/paint

18. Black sink undercoating

19. Tan FRP mastic

20. Beige 2” x 2” ceramic wall tile, grout & mortar

21. Tan millwork glue

22. Gray vinyl plank flooring & yellow mastic

23. Black ceramic wall tile, grout, & mortar

24. White 4” x 8” ceramic wall tile, grout, & mortar

25. Gray 12” x 24” ceramic floor tile, grout, mortar, & yellow mastic

26. Drywall, smooth paint/texture, & joint compound

27. Yellow carpet mastic

28. Black cove base & tan adhesive

29. White 2’ x 2’ lay-in acoustic ceiling tile (rough finish)

30. White 12” x 12” vinyl floor tile & yellow mastic

31. Residual brown mastic dots

32. Interior window caulk

33. Gray HVAC duct mastic

34. White 2’ x 2’ lay-in acoustic ceiling tile (multi-size pinhole pattern)

35. Brown & orange ceramic floor tile, grout & mortar

36. 3” Pipe insulation (paper/foil wrap)

37. 3” Pipe fitting insulation (paper/foil wrap)

38. Domestic water line insulation & black mastic

39. Exterior EIFS (synthetic foam, plaster, & stucco)

40. Exterior brick mortar

41. Textured wall concrete

42. Exterior door/window frame caulk

43. Exterior wall joint seam caulk

44. Exterior door caulk

45. Pad concrete

46. Exterior marble wall panel adhesive (white)

47. Exterior soffit plaster

48. Exterior vapor barrier material & sealant

49. Plaster wall with rough texture

50. Unfinished gypsum firewall & joint compound

51. Brown cove base mastic

52. Brick & mortar

53. Gray HVAC duct mastic

54. Roof penetration sealant

55. Parapet flashing seam caulk (gray & white)

56. Sidewalk concrete

57. Driveway concrete

58. Roof core materials

IV. RECOMMENDATIONS

Based on observations made at the Site, and results of the analysis of bulk samples collected during the inspection, Farmer recommends the following:

1. TAHPR dictates that only a licensed Asbestos Abatement Contractor can remove, repair, enclose, or encapsulate asbestos containing material. TAHPR further dictates that the asbestos abatement activity be monitored by a licensed Asbestos Consultant.

2. According to TAHPR, TDSHS must be notified of any asbestos abatement of a structure regardless of size. Notifications must be postmarked at least 10 working days before initiating abatement activities and must be made using TDSHS forms. Forms can be obtained by contacting the TDSHS Asbestos Notification and Information Section at 1-800-572-5548 or online through the TDSHS website at www.dshs.state.tx.us.

3. To comply with National Emission Standards for Hazardous Air Pollutants (NESHAP) asbestos regulation (EPA 40 CFR 61, Subpart M), Farmer recommends removing all friable and non-friable ACBM that has the potential to become friable under abatement conditions prior to renovation or demolition activities.

4. Additional bulk samples should be collected from previously concealed materials that may be revealed during demolition activity, or from materials outside the original inspection scope of work. "Suspect" material includes any material serving as a sprayed on or troweled on acoustic or fireproofing surface; floor and ceiling tiles; transite panels, siding or shingles;

thermal insulation or any material associated with mechanical systems; or any binding agent such as tar sealant, mastic adhesive, roofing tar, caulking, et cetera. TDSHS regulations require bulk samples in public buildings be collected by a licensed asbestos inspector or individual asbestos consultant.

5. The building owner should be aware that removing ACBM does not discharge ownership.

During transport or after burial in an EPA-approved landfill, any contamination throughout the lifetime of the material remains the responsibility of the building owner.

6. If any material cannot be positively identified as non-asbestos containing by the analytical results of samples collected during this inspection, it should be treated as asbestos until a sample of the newly identified suspect material can be collected and analyzed by PLM.

7. According to the Occupational Safety and Health Administration (OSHA) 29 Code of Federal

Regulations (CFR) 1926.1101, building and/or facility owners shall notify the following persons of the presence, location, and quantity of asbestos-containing materials, at the work sites in their buildings. Notification either shall be in writing, or shall consist of a personal communication between the owner and the person to whom notification must be given or their authorized representative:

a) Prospective employers applying or bidding for work whose employees reasonably can be expected to work in or adjacent to areas containing such material;

b) Employees of the owner who will work in or adjacent to areas containing such material;

c) On multi-employer work sites, all employers of employees who will be performing work within or adjacent to areas containing such materials;

d) Tenants who will occupy areas containing such material.

V. LIMITATIONS

Farmer has endeavored to inspect the existing conditions within the affected areas using TAHPR inspection protocols. Regardless of the thoroughness of an inspection, it is possible that some areas containing asbestos were overlooked or inaccessible. This report presents general descriptions of various construction materials and the general locations where these materials were encountered. If questions arise during the planning for renovation, demolition or other construction, Farmer should be notified to permit a review of the situation and to present recommendations. Asbestos Abatement Contractors bidding on ACBM removal activities shall be responsible for verifying ACBM quantities and site conditions prior to submitting bids.

Farmer will be happy to assist with obtaining competitive bids from qualified asbestos abatement contractors. Farmer can arrange a bid meeting and assist in the contractor selection process. Additionally, Farmer can conduct abatement project design, air monitoring, & clearance testing for any abatement activities.

This report has been prepared on behalf of and exclusively for the use of the City of McKinney and their client. The conclusions expressed by Farmer regarding the conditions of the site are based solely on the observations made on December 9 & 10, 2025, the data collected during this inspection, and the laboratory results of the samples collected and analyzed.

The beneficiaries are hereby advised that conditions observed are subject to change. This report and the findings contained herein shall not, in whole or in part, be disseminated or conveyed to any other party or be used or relied upon by any other party, in whole or in part, without the City of McKinney’s or Farmer's prior written consent.

APPENDIX I

BULK SAMPLE ANALYSIS

PLM Summary Report

Client :

Project :

Project # :

Identification :

Test Method :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

2040.52 Cof McKinney

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 12/11/2025, one hundred sixty nine (169) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

25B-14463

12/09/2025 -

12/10/2025

01/06/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

E66780 Ceramic Wall Tile (Black), Grout and Adhesive, Reception

Area (Level 2)

None Detected - Ceramic Tile

None Detected - Grout

None Detected - White Adhesive

E66781 Ceramic Wall Tile (Black), Grout and Adhesive, Reception

Area (Level 2)

None Detected - Ceramic Tile

None Detected - Grout

None Detected - White Adhesive

E66782 Ceramic Wall Tile (Black), Grout and Adhesive, Reception

Area (Level 2)

None Detected - Ceramic Tile

None Detected - Grout

None Detected - White Adhesive

E66783 Millwork Caulk, Room 215 None Detected - Caulking

E66784 Millwork Caulk, Room 215 None Detected - Caulking

E66785 Millwork Caulk, Room 215 None Detected - Caulking

E66786 Millwork Glue (Black), Room 217 None Detected - Black Glue

E66787 Millwork Glue (Black), Room 217 None Detected - Black Glue

E66788 Millwork Glue (Black), Room 217 None Detected - Black Glue

E66789 Glass Tile Wall Mortar, East Stairwell None Detected - Mortar

E66790 Glass Tile Wall Mortar, East Stairwell None Detected - Mortar

E66791 Glass Tile Wall Mortar, East Stairwell None Detected - Mortar

E66792 Textured Wall Concrete, Level 1, Mechanical Room None Detected - Concrete

None Detected - Texture

E66793 Textured Wall Concrete, Level 1, Mechanical Room None Detected - Concrete

None Detected - Texture

E66794 Textured Wall Concrete, Level 1, Mechanical Room None Detected - Concrete

None Detected - Texture

E66795 HVAC Duct Mastic (Beige), Level 1, Mechanical Room None Detected - Beige Mastic

E66796 HVAC Duct Mastic (Beige), Level 1, Mechanical Room None Detected - Beige Mastic

Project :

Project # :

Identification :

Test Method :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

2040.52 Cof McKinney

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 12/11/2025, one hundred sixty nine (169) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

25B-14463

12/09/2025 -

12/10/2025

01/06/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

E66797 HVAC Duct Mastic (Beige), Level 1, Mechanical Room None Detected - Beige Mastic

E66798 CMU Block with Texture / Filler, Level 1, Mechanical

Room

None Detected - CMU

None Detected - Mortar

None Detected - Filler Material

E66799 CMU Block with Texture / Filler, Level 1, Mechanical

Room

None Detected - CMU

None Detected - Mortar

None Detected - Filler Material

E66800 CMU Block with Texture / Filler, Level 1, Mechanical

Room

None Detected - CMU

None Detected - Mortar

None Detected - Filler Material

E66801 6" x 6" Ceramic Floor Tile (Gray), Grout and Mortar, Level

1, Mens Room

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66802 6" x 6" Ceramic Floor Tile (Gray), Grout and Mortar, Level

2, Womens Room

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66803 6" x 6" Ceramic Floor Tile (Gray), Grout and Mortar, Level

2, Mens Room

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66804 4" x 4" Ceramic Wall Tile (White), Grout and Adhesive, Level 1, Mens Room

None Detected - Ceramic Tile

None Detected - Grout

None Detected - White Adhesive

E66805 4" x 4" Ceramic Wall Tile (White), Grout and Adhesive, Level 2, Mens Room

None Detected - Ceramic Tile

None Detected - Grout

None Detected - White Adhesive

E66806 4" x 4" Ceramic Wall Tile (White), Grout and Adhesive, Level 2, Womens Room

None Detected - Ceramic Tile

None Detected - Grout

None Detected - White Adhesive

E66807 Ceramic Tile Wall Base (Gray), Grout and Adhesive, Level

1, Mens Room

None Detected - Ceramic Tile

None Detected - Grout

None Detected - White Adhesive

Project :

Project # :

Identification :

Test Method :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

2040.52 Cof McKinney

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 12/11/2025, one hundred sixty nine (169) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

25B-14463

12/09/2025 -

12/10/2025

01/06/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

E66808 Ceramic Tile Wall Base (Gray), Grout and Adhesive, Level

2, Mens Room

None Detected - Ceramic Tile

None Detected - Grout

None Detected - White Adhesive

E66809 Ceramic Tile Wall Base (Gray), Grout and Adhesive, Level

2, Womens Room

None Detected - Ceramic Tile

None Detected - Grout

None Detected - White Adhesive

E66810 Carpet Mastic (Yellow), Room 222 None Detected - Yellow Mastic

E66811 Carpet Mastic (Yellow), Room 226 None Detected - Yellow Mastic

E66812 Carpet Mastic (Yellow), Room 218 None Detected - Yellow Mastic

E66813 Drywall, Texture (Smooth) and Joint Compound, Room 207 None Detected - Drywall Material

None Detected - Texture / Joint Cmpd

E66814 Drywall, Texture (Smooth) and Joint Compound, Room 220 None Detected - Drywall Material

None Detected - Texture / Joint Cmpd

E66815 Drywall, Texture (Smooth) and Joint Compound, Room 203 None Detected - Drywall Material

None Detected - Texture / Joint Cmpd

E66816 Drywall with Wall Cover and Joint Compound, Room 226 None Detected - Drywall Material

None Detected - Joint Compound

None Detected - Wall Covering

E66817 Drywall with Wall Cover and Joint Compound, Room 226 None Detected - Drywall Material

None Detected - Joint Compound

None Detected - Wall Covering

E66818 Drywall with Wall Cover and Joint Compound, Room 204 None Detected - Drywall Material

None Detected - Joint Compound

None Detected - Wall Covering

E66819 Terrazzo Flooring, Room 218 under Carpet None Detected - Tan Mastic

None Detected - Terrazzo

E66820 Terrazzo Flooring, Room 200 under Carpet None Detected - Tan Mastic

None Detected - Terrazzo

Project :

Project # :

Identification :

Test Method :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

2040.52 Cof McKinney

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 12/11/2025, one hundred sixty nine (169) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

25B-14463

12/09/2025 -

12/10/2025

01/06/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

E66821 Terrazzo Flooring, Room 221A under Carpet None Detected - Tan Mastic

None Detected - Terrazzo

E66822 Plaster with Texture, East Stairwell None Detected - Plaster

None Detected - Paint / Texture

E66823 Plaster with Texture, East Stairwell None Detected - Plaster

None Detected - Paint / Texture

E66824 Plaster with Texture, East Stairwell None Detected - Plaster

None Detected - Paint / Texture

E66825 Interior Brick Mortar, Level 1 None Detected - Brick

None Detected - Mortar

E66826 Interior Brick Mortar, Level 1 None Detected - Brick

None Detected - Mortar

E66827 Interior Brick Mortar, Level 2 None Detected - Brick

None Detected - Mortar

E66828 Plaster with Texture (Sandy), Level 1, At Kitchen None Detected - Plaster

None Detected - Paint / Texture

E66829 Plaster with Texture (Sandy), Level 1, At Kitchen None Detected - Plaster

None Detected - Paint / Texture

E66830 Plaster with Texture (Sandy), Level 1, At Kitchen None Detected - Plaster

None Detected - Paint / Texture

E66831 Sink Undercoat (Black), Level 1, Break Room None Detected - Sink Undercoating

E66832 Sink Undercoat (Black), Level 1, Break Room None Detected - Sink Undercoating

E66833 Sink Undercoat (Black), Level 1, Break Room None Detected - Sink Undercoating

E66834 FRP Mastic (Yellow), Level 1, Janitor Closet None Detected - Fiberglass Panel

None Detected - Tan Mastic

E66835 FRP Mastic (Yellow), Level 1, Janitor Closet None Detected - Fiberglass Panel

None Detected - Tan Mastic

Project :

Project # :

Identification :

Test Method :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

2040.52 Cof McKinney

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 12/11/2025, one hundred sixty nine (169) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

25B-14463

12/09/2025 -

12/10/2025

01/06/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

E66836 FRP Mastic (Yellow), Level 1, Janitor Closet None Detected - Fiberglass Panel

None Detected - Tan Mastic

E66837 2" x 2" Ceramic Wall Tile (Beige), Grout and Adhesive, Level 1, Janitor Closet

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66838 2" x 2" Ceramic Wall Tile (Beige), Grout and Adhesive, Level 1, Janitor Closet

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66839 2" x 2" Ceramic Wall Tile (Beige), Grout and Adhesive, Level 1, Janitor Closet

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66840 Millwork Glue (Yellow), Level 2, Mens Room None Detected - Tan Glue

E66841 Millwork Glue (Yellow), Level 2, Womens Room None Detected - Tan Glue

E66842 Millwork Glue (Yellow), Level 1, Womens Room None Detected - Tan Glue

E66843 Vinyl Plank Flooring (Gray), Mastic (Yellow) and Floor

Float, Level 1, Lobby

None Detected - Flooring

None Detected - Yellow Mastic

E66844 Vinyl Plank Flooring (Gray), Mastic (Yellow) and Floor

Float, Level 1, Lobby

None Detected - Flooring

None Detected - Yellow Mastic

E66845 Vinyl Plank Flooring (Gray), Mastic (Yellow) and Floor

Float, Level 1, Lobby

None Detected - Flooring

None Detected - Yellow Mastic

E66846 Ceramic Wall Tile (Black), Grout and Mortar, Level 1, Lobby

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66847 Ceramic Wall Tile (Black), Grout and Mortar, Level 1, Lobby

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66848 Ceramic Wall Tile (Black), Grout and Mortar, Level 1, Lobby

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

Project :

Project # :

Identification :

Test Method :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

2040.52 Cof McKinney

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 12/11/2025, one hundred sixty nine (169) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

25B-14463

12/09/2025 -

12/10/2025

01/06/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

E66849 4" x 8" Ceramic Wall Tile (White) Grout and Mortar, Level

1, Lobby Restroom

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66850 4" x 8" Ceramic Wall Tile (White) Grout and Mortar, Level

1, Lobby Restroom

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66851 4" x 8" Ceramic Wall Tile (White) Grout and Mortar, Level

1, Lobby Restroom

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66852 12" x 24" Ceramic Floor Tile (Gray), Grout and Mortar, with

Mastic (Yellow), Level 1, Lobby Restroom

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

None Detected - Yellow Mastic

E66853 12" x 24" Ceramic Floor Tile (Gray), Grout and Mortar, with

Mastic (Yellow), Level 1, Lobby Restroom

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

None Detected - Yellow Mastic

E66854 12" x 24" Ceramic Floor Tile (Gray), Grout and Mortar, with

Mastic (Yellow), Level 1, Lobby Restroom

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

None Detected - Yellow Mastic

E66855 Drywall, Texture (Smooth) and Joint Compound, Room 124 None Detected - Drywall Material

None Detected - Texture / Joint Cmpd

E66856 Drywall, Texture (Smooth) and Joint Compound, Room 115 None Detected - Drywall Material

None Detected - Texture / Joint Cmpd

E66857 Drywall, Texture (Smooth) and Joint Compound, Room 117 None Detected - Drywall Material

None Detected - Texture / Joint Cmpd

E66858 Carpet Mastic (Yellow), Room 133 None Detected - Yellow Mastic

E66859 Carpet Mastic (Yellow), Room 121 None Detected - Yellow Mastic

E66860 Carpet Mastic (Yellow), Room 124 None Detected - Yellow Mastic

Project :

Project # :

Identification :

Test Method :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

2040.52 Cof McKinney

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 12/11/2025, one hundred sixty nine (169) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

25B-14463

12/09/2025 -

12/10/2025

01/06/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

E66861 Cove Base (Black) with Adhesive, Level 2, Storage None Detected - Cove Base

None Detected - Tan Adhesive

E66862 Cove Base (Black) with Adhesive, Level 1, Room 134 None Detected - Cove Base

None Detected - Tan Adhesive

E66863 Cove Base (Black) with Adhesive, Level 1, Room 134 None Detected - Cove Base

None Detected - Tan Adhesive

E66864 2' x 2' Lay-in Ceiling Tile (White, Rough Finish), Level 2, Open

None Detected - Acoustic Tile

E66865 2' x 2' Lay-in Ceiling Tile (White, Rough Finish), Level 2, Open

None Detected - Acoustic Tile

E66866 2' x 2' Lay-in Ceiling Tile (White, Rough Finish), Level 1, Open

None Detected - Acoustic Tile

E66867 12" x 12" Vinyl Floor Tile (White) with Mastic (Yellow), Room 206

None Detected - Floor Tile

None Detected - Yellow Mastic

E66868 12" x 12" Vinyl Floor Tile (White) with Mastic (Yellow), Room 127

None Detected - Floor Tile

None Detected - Yellow Mastic

E66869 12" x 12" Vinyl Floor Tile (White) with Mastic (Yellow), Room 129

None Detected - Floor Tile

None Detected - Yellow Mastic

E66870 Residual Mastic Dots (Brown), Room 201 None Detected - Brown Mastic

E66871 Residual Mastic Dots (Brown), Room 201 None Detected - Brown Mastic

E66872 Residual Mastic Dots (Brown), Room 201 None Detected - Brown Mastic

E66873 Interior Window Caulk, Room 207 None Detected - Caulking

E66874 Interior Window Caulk, Room 207 None Detected - Caulking

E66875 Interior Window Caulk, Room 207 None Detected - Caulking

E66876 HVAC Mastic (Gray), Level 1, Corridor 146 None Detected - Gray Mastic

E66877 HVAC Mastic (Gray), Level 1, Corridor 144 None Detected - Gray Mastic

Project :

Project # :

Identification :

Test Method :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

2040.52 Cof McKinney

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 12/11/2025, one hundred sixty nine (169) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

25B-14463

12/09/2025 -

12/10/2025

01/06/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

E66878 HVAC Mastic (Gray), Level 1, Corridor 141 None Detected - Gray Mastic

E66879 2' x 2' Lay-in Ceiling Tile (White, Multi-size Pinholes), Level 1, Kitchen

None Detected - Acoustic Tile

E66880 2' x 2' Lay-in Ceiling Tile (White, Multi-size Pinholes), Level 1, Janitor Closet

None Detected - Acoustic Tile

E66881 2' x 2' Lay-in Ceiling Tile (White, Multi-size Pinholes), Level 1, Janitor Closet

None Detected - Acoustic Tile

E66882 Ceramic Floor Tile (Brown and Orange) Grout and Mortar, Level 1, Lobby at Stairs

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66883 Ceramic Floor Tile (Brown and Orange) Grout and Mortar, Level 1, Lobby at Stairs

No Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66884 Ceramic Floor Tile (Brown and Orange) Grout and Mortar, Level 1, Lobby at Stairs

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Mortar

E66885 3" Pipe Insulation (Paper, Foil and Fiberglass Wrap), Level

1, Corridor at 146

None Detected - Paper / Foil Wrap

E66886 3" Pipe Insulation (Paper, Foil and Fiberglass Wrap), Level

1, Corridor at 143

None Detected - Paper / Foil Wrap

E66887 3" Pipe Insulation (Paper, Foil and Fiberglass Wrap), Level

1, Corridor at 144

None Detected - Paper / Foil Wrap

E66888 3" Pipe Fitting Insulation (Paper, Foil and Fiberglass Wrap), Level 1, Corridors

None Detected - Paper / Foil Wrap

E66889 3" Pipe Fitting Insulation (Paper, Foil and Fiberglass Wrap), Level 1, Corridors

None Detected - Paper / Foil Wrap

E66890 3" Pipe Fitting Insulation (Paper, Foil and Fiberglass Wrap), Level 1, Corridors

None Detected - Paper / Foil Wrap

Project :

Project # :

Identification :

Test Method :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

2040.52 Cof McKinney

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 12/11/2025, one hundred sixty nine (169) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

25B-14463

12/09/2025 -

12/10/2025

01/06/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

E66891 Domestic Water Line Insulation, Level 1, Corridors None Detected - Thermal Insulation

None Detected - Paper / Foil Wrap

None Detected - Black Mastic

E66892 Domestic Water Line Insulation, Level 1, Corridors None Detected - Thermal Insulation

None Detected - Paper / Foil Wrap

None Detected - Black Mastic

E66893 Domestic Water Line Insulation, Level 1, Corridors None Detected - Thermal Insulation

None Detected - Paper / Foil Wrap

None Detected - Black Mastic

E66894 Exterior EIFS, Loading Dock Door Opening None Detected - Synthetic Foam

None Detected - Plaster

None Detected - Stucco

E66895 Exterior EIFS, Loading Dock Door Opening None Detected - Synthetic Foam

None Detected - Plaster

None Detected - Stucco

E66896 Exterior Brick Mortar, West Side of Building None Detected - Mortar

E66897 Exterior Brick Mortar, South Side at Dock None Detected - Mortar

E66898 Textured Wall Concrete, North Retaining Wall None Detected - Concrete

None Detected - Textured Paint

E66899 Textured Wall Concrete, North Building Wall None Detected - Concrete

None Detected - Textured Paint

E66900 Exterior Door / Window Frame Caulk, Level 1, Entrance None Detected - Caulking

E66901 Exterior Door / Window Frame Caulk, Level 2, Entrance None Detected - Caulking

E66902 Exterior Wall Joint Seam Caulk, West Side of Building None Detected - Caulking

E66903 Exterior Wall Joint Seam Caulk, South Side of Building None Detected - Caulking

E66904 Exterior Door Caulk, Loading Dock None Detected - Caulking

E66905 Exterior Door Caulk, Loading Dock None Detected - Caulking

Project :

Project # :

Identification :

Test Method :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

2040.52 Cof McKinney

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 12/11/2025, one hundred sixty nine (169) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

25B-14463

12/09/2025 -

12/10/2025

01/06/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

E66906 Pad Concrete, North Side of Building None Detected - Concrete

E66907 Pad Concrete, South Side of Building None Detected - Concrete

E66908 Exterior Marble Wall Panel Adhesive, East Wall None Detected - White Adhesive

E66909 Exterior Marble Wall Panel Adhesive, East Wall None Detected - White Adhesive

E66910 Exterior Marble Wall Panel Seam Caulk, East Wall None Detected - Caulking

E66911 Exterior Marble Wall Panel Seam Caulk, East Wall None Detected - Caulking

E66912 Exterior Soffit Plaster, West Side Entry None Detected - Base Plaster

None Detected - Top Plaster

E66913 Exterior Soffit Plaster, East Side Entry None Detected - Base Plaster

None Detected - Top Plaster

E66914 Exterior Soffit Plaster, East Side Entry None Detected - Base Plaster

None Detected - Top Plaster

E66915 Exterior Vapor Barrier Material, North Side of Building None Detected - Vapor Barrier 1

None Detected - Vapor Barrier 2

None Detected - Sealant

E66916 Exterior Vapor Barrier Material, North Side of Building None Detected - Vapor Barrier 1

None Detected - Vapor Barrier 2

None Detected - Sealant

E66917 Vinyl Cove Base with Adhesive, Fire Riser Room 2% Chrysotile - Cove Base

None Detected - Tan Adhesive

E66918 Vinyl Cove Base with Adhesive, Fire Riser Room Not Analyzed - Positive Stop

E66919 Vinyl Cove Base with Adhesive, Fire Riser Room Not Analyzed - Positive Stop

E66920 Plaster (Wall with Rough Texture), Fire Riser Room None Detected - Plaster

E66921 Plaster (Wall with Rough Texture), Fire Riser Room None Detected - Plaster

E66922 Plaster (Wall with Rough Texture), Fire Riser Room None Detected - Plaster

Project :

Project # :

Identification :

Test Method :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

2040.52 Cof McKinney

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 12/11/2025, one hundred sixty nine (169) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

25B-14463

12/09/2025 -

12/10/2025

01/06/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

E66923 Unfinished Gypsum Firewall, Fire Riser Room None Detected - Drywall Material

None Detected - Joint Compound

E66924 Unfinished Gypsum Firewall, Fire Riser Room None Detected - Drywall Material

None Detected - Joint Compound

E66925 Unfinished Gypsum Firewall, Fire Riser Room None Detected - Drywall Material

None Detected - Joint Compound

E66926 Cove Base Mastic (Brown), Fire Riser Room None Detected - Brown Mastic

E66927 Cove Base Mastic (Brown), Fire Riser Room None Detected - Brown Mastic

E66928 Cove Base Mastic (Brown), Fire Riser Room None Detected - Brown Mastic

E66929 Brick and Mortar, Fire Riser Room None Detected - Brick

None Detected - Mortar

E66930 Brick and Mortar, Fire Riser Room None Detected - Brick

None Detected - Mortar

E66931 Brick and Mortar, Fire Riser Room None Detected - Brick

None Detected - Mortar

E66932 Residual Roofing Tar, Parapet 10% Chrysotile - Roofing Tar

E66933 Residual Roofing Tar, Parapet Not Analyzed - Positive Stop

E66934 HVAC Duct Mastic, Roof None Detected - Gray Mastic

E66935 HVAC Duct Mastic, Roof None Detected - Gray Mastic

E66936 Roof Penetration Sealant, Central Roof None Detected - Sealant

E66937 Roof Penetration Sealant, Central Roof None Detected - Sealant

E66938A Parapet Flashing Seam Caulk, South Parapet None Detected - White Caulking

None Detected - Gray Caulking

E66937B Parapet Flashing Seam Caulk, West Roof Parapet None Detected - White Caulking

None Detected - Gray Caulking

Project :

Project # :

Identification :

Test Method :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

2040.52 Cof McKinney

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 12/11/2025, one hundred sixty nine (169) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

25B-14463

12/09/2025 -

12/10/2025

01/06/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

E66938 Roof Seam Tar, North Parapet 10% Chrysotile - RoofingTar

E66939 Roof Seam Tar, North Parapet Not Analyzed - Positive Stop

E66940 Sidewalk Concrete, West Side None Detected - Concrete

E66941 Sidewalk Concrete, West Side None Detected - Concrete

E66942 Driveway Concrete, West Parking None Detected - Concrete

E66943 Driveway Concrete, West Parking None Detected - Concrete

E66944 Roof Core Material, Central Main Roof None Detected - Roofing Membrane

None Detected - Foam Insulation 1

None Detected - Sealant

None Detected - Roof Membrane

None Detected - Roofing Tars

None Detected - Roofing Felts

None Detected - Felt Facing

None Detected - Foam Insulation 2

None Detected - Felt Backing

None Detected - Fiberboard

E66945 Roof Core Material, West Entrance None Detected - Roofing Membrane

None Detected - Foam Insulation 1

None Detected - Sealant

None Detected - Roof Membrane

None Detected - Roofing Tars

None Detected - Roofing Felts

None Detected - Felt Facing

None Detected - Foam Insulation 2

None Detected - Felt Backing

Project :

Project # :

Identification :

Test Method :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

2040.52 Cof McKinney

Asbestos, Bulk Sample Analysis

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 12/11/2025, one hundred sixty nine (169) bulk material samples were submitted by a representative of Farmer Environmental Group for asbestos analysis by PLM/DS. The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Lab Job No. :

Report Date :

25B-14463

12/09/2025 -

12/10/2025

01/06/2026

NVLAP Lab Code 102056-0

TDSHS License No. 300084

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

E66946 Roof Core Material, North Roof None Detected - Roofing Membrane

None Detected - Foam Insulation 1

None Detected - Sealant

None Detected - Roof Membrane

None Detected - Roofing Tars

None Detected - Roofing Felts

None Detected - Felt Facing

None Detected - Foam Insulation 2

None Detected - Felt Backing

Amy Le, Debra O'Sullivan, Ellie Regier, Heather Lopez, Jacob SutherlaAnalyst(s):

Lab Director : Bruce Crabb Approved Signatory :

Thank you for choosing Moody Labs

Lab Manager : Heather Lopez Approved Signatory :

These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual estimate. The test report shall not be reproduced except in full without written approval of the laboratory. The results relate only to the items tested. These test results do not imply endorsement by NVLAP or any agency of the U.S.

Government. Accredited by the National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis under Lab Code 102056-0.

This Page Left Intentionally Blank

PLM Detail Report

Project # : 2040.52 Cof McKinney

Sample Number Layer Components % Of

Sample

Analysis

Date

% of

Layer Analyst

Supplement to PLM Summary Report

Client :

Project :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

Lab Job No. :

Report Date :

25B-14463 002

01/06/2026

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

Moody Labs NVLAP Lab Code 102056-0

TDSHS License No. 300084

Sintered ClaysE66780 Ceramic Tile (Black) 85% 12/17100% AL

AggregateE66780 Grout (Black) 10% 12/1750% AL

Calcite / BindersE66780 Grout (Black) 10% 12/1750% AL

CalciteE66780 White Adhesive (White) 5% 12/1750% AL

Binders / FillersE66780 White Adhesive (White) 5% 12/1750% AL

Sintered ClaysE66781 Ceramic Tile (Black) 85% 12/17100% AL

AggregateE66781 Grout (Black) 8% 12/1750% AL

Calcite / BindersE66781 Grout (Black) 8% 12/1750% AL

CalciteE66781 White Adhesive (White) 7% 12/1750% AL

Binders / FillersE66781 White Adhesive (White) 7% 12/1750% AL

Sintered ClaysE66782 Ceramic Tile (Black) 80% 12/17100% AL

AggregateE66782 Grout (Black) 15% 12/1750% AL

Calcite / BindersE66782 Grout (Black) 15% 12/1750% AL

CalciteE66782 White Adhesive (White) 5% 12/1750% AL

Binders / FillersE66782 White Adhesive (White) 5% 12/1750% AL

CalciteE66783 Caulking (White) 100% 12/1760% AL

Binders / FillersE66783 Caulking (White) 100% 12/1740% AL

CalciteE66784 Caulking (White) 100% 12/1760% AL

Binders / FillersE66784 Caulking (White) 100% 12/1740% AL

CalciteE66785 Caulking (White) 100% 12/1760% AL

Binders / FillersE66785 Caulking (White) 100% 12/1740% AL

CalciteE66786 Black Glue (Black) 100% 12/1760% AL

Binders / FillersE66786 Black Glue (Black) 100% 12/1740% AL

CalciteE66787 Black Glue (Black) 100% 12/1760% AL

Binders / FillersE66787 Black Glue (Black) 100% 12/1740% AL

CalciteE66788 Black Glue (Black) 100% 12/1760% AL

Binders / FillersE66788 Black Glue (Black) 100% 12/1740% AL

AggregateE66789 Mortar (Gray) 100% 12/1765% AL

Cement BindersE66789 Mortar (Gray) 100% 12/1735% AL

Sample Number Layer Components % Of

Sample

Analysis

Date

% of

Layer Analyst

Supplement to PLM Summary Report

Client :

Project :

Farmer Environmental Group

Development Services Bldg., 220 N. Kentucky St.

Lab Job No. :

Report Date :

25B-14463 002

01/06/2026

2051 Valley View Lane

Farmers Branch, TX 75234 Phone: (972) 241-8460

Moody Labs NVLAP Lab Code 102056-0

TDSHS License No. 300084

AggregateE66790 Mortar (Gray) 100% 12/1765% AL

Cement BindersE66790 Mortar (Gray) 100% 12/1735% AL

AggregateE66791 Mortar (Gray) 100% 12/1765% AL

Cement BindersE66791 Mortar (Gray) 100% 12/1735% AL

AggregateE66792 Concrete (Gray) 85% 12/1765% AL

Cement BindersE66792 Concrete (Gray) 85% 12/1735% AL

Calcite / Talc / BindersE66792 Texture (White) 15% 12/17100% AL

AggregateE66793 Concrete (Gray) 90% 12/1765% AL

Cement BindersE66793 Concrete (Gray) 90% 12/1735% AL

Calcite / Talc / BindersE66793 Texture (White) 10% 12/17100% AL

AggregateE66794 Concrete (Gray) 85% 12/1765% AL

Cement BindersE66794 Concrete (Gray) 85% 12/1735% AL

Calcite / Talc / BindersE66794 Texture (White) 15% 12/17100% AL

CalciteE66795 Beige Mastic (Beige) 100% 12/1750% AL

Glue BindersE66795 Beige Mastic (Beige) 100% 12/1750% AL

CalciteE66796 Beige Mastic (Beige) 100% 12/1750% AL

Glue BindersE66796 Beige Mastic (Beige) 100% 12/1750% AL

CalciteE66797 Beige Mastic (Beige) 100% 12/1750% AL

Glue BindersE66797 Beige Mastic (Beige) 100% 12/1750% AL

AggregateE66798 CMU (Gray) 60% 12/1765% JS

Cement BindersE66798 CMU (Gray) 60% 12/1735% JS

AggregateE66798 Mortar (Gray) 38% 12/1765% JS

Cement BindersE66798 Mortar (Gray) 38% 12/1735% JS

Calcite / BindersE66798 Filler Material (White) 2% 12/17100% JS

AggregateE66799 CMU (Gray) 43% 12/1765% JS

Cement BindersE66799 CMU (Gray) 43% 12/1735% JS

AggregateE66799 Mortar (Gray) 55% 12/1765% JS

Cement BindersE66799 Mortar (Gray) 55% 12/1735% JS

Calcite / BindersE66799 Filler Material (White) 2% 12/17100% JS

Sample Number Layer…

This is the start of the file's text. The full file is on GovTribe.