5-ES Plans.PDF
PDF 3 MB Posted
- Solicitation number
- Not on record
- Issued by
- Somerset County, South Pottstown CDP, Pennsylvania
About this file
The document is a comprehensive engineering plan for the Julia Street (T-652) Bridge Superstructure Replacement project, prepared by Alfred Benesch & Company for Girardville Borough and Butler Township in Schuylkill County, Pennsylvania. The project involves replacing the existing bridge superstructure over Mahanoy Creek with a new structure, with a detailed construction sequence that includes traffic detour, site clearing, temporary erosion control installation, existing superstructure removal, new superstructure construction, backfilling, and site stabilization. The plan provides specific erosion and sedimentation control measures, with a construction timeline that explicitly prohibits tree removal between May 15 and August 15, and outlines strict environmental protection guidelines in accordance with Pennsylvania's regulatory requirements.
The engineering plan includes comprehensive technical specifications for site preparation, fill placement, topsoil management, and stabilization, with specific requirements for soil handling, compaction, and vegetative cover. The project has a relatively small disturbance footprint of 0.10 acres, and emphasizes environmental compliance through detailed erosion control protocols, including weekly inspections of erosion and sediment best management practices (BMPs), immediate stabilization of disturbed areas, and specific procedures for handling potential environmental risks. The plan requires contractors to follow strict guidelines for sediment control, waste management, and site restoration, with potential administrative, civil, and criminal penalties for non-compliance with environmental regulations.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Rev Date By Chk'd Description
Copyright 2024, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of
Date:Scale: Project No.: Sheet No.:AS NOTED 7/24/2024 32020.00Drawn: Designed: Checked: OF
570-622-4055
Pottsville, PA 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Girardville Borough & Butler Township, Schuylkill County, Pennsylvania
OVER MAHANOY CREEK
SUPERSTRUCTURE REPLACEMENT
JULIA STREET (T-652)
U
S E
R C
F G
U
S E
R
D
A T
E
T
IM
E
F
IL
E
P E
N
N S Y L V
A
N
I A
C O
M
M O
NW EALT
H
O
F
REGISTERED
PROFESSIONAL
ENGINEER
PE081136
JOHN C. KNECHT
GENERAL NOTES
EROSION AND SEDIMENTATION POLLUTION CONTROL
AT WWW.PAONECALL.ORG
COORDINATE YOUR PROJECTS VIA COORDINATE PA
PENNSYLVANIA ONE CALL SYSTEM SERIAL NUMBER
20231641674
START OF EXCAVATION.
THAN 10 BUSINESS DAYS PRIOR TO THE
THAN 3 BUSINESS DAYS NOR MORE
DIAL 8-1-1 OR 1-800-242-1776 NOT LESS
EROSION CONTROL POLICIES AND MAINTENANCE PROGRAM
ENVIRONMENTAL PROTECTION AND THE ENGINEERS REPRESENTATIVE:
GUIDELINES AS THEY ARE APPLICABLE AND IN ACCORDANCE TO THE INSTRUCTIONS OF THE DEPARTMENT OF
CONTROL EROSION, IT IS REQUIRED THAT THE CONTRACTOR FOR THIS PROJECT CONFORMS WITH THE FOLLOWING
IN ACCORDANCE WITH THE CURRENT POLICIES AND PRACTICES IN THE COMMONWEALTH OF PENNSYLVANIA TO
EROSION CONTROL POLICIES (CONTINUED)
39. DO NOT CONDUCT TREE REMOVAL BETWEEN MAY 15 AND AUGUST 15.
SURFACE WATER AND ON ALL OTHER DISTURBED AREAS SPECIFIED ON THE PLAN MAPS AND/OR DETAIL SHEETS.
EROSION CONTROL BLANKETING SHALL BE INSTALLED ON ALL SLOPES 3H:1V OR STEEPER WITHIN 50 FEET OF A 38.
THIS PLAN UNTIL SUCH RESTORATION IS COMPLETE.
ANY BASE FLOW WITHIN THE CHANNEL SHALL BE CONVEYED PAST THE WORK AREA IN THE MANNER DESCRIBED IN 37.
THAT THE DESIGN DIMENSIONS WILL BE PROVIDED AFTER PLACEMENT OF THE PROTECTIVE LINING.
CHANNELS HAVING RIPRAP, RENO MATTRESS, OR GABION LININGS MUST BE SUFFICIENTLY OVER-EXCAVATED SO 36.
SHALL IT BE ALLOWED TO ENTER ANY SURFACE WATERS OR GROUNDWATER SYSTEMS.
CONCRETE WASH WATER SHALL BE HANDLED IN THE MANNER DESCRIBED ON THE PLAN DRAWINGS. IN NO CASE 35.
IN MISDEMEANOR CRIMINAL PENALTIES FOR EACH VIOLATION.
UP TO $10,000 PER DAY IN CIVIL PENALTIES, UP TO $10,000 IN SUMMARY CRIMINAL PENALTIES, AND UP TO $25,000
DEFINED IN SECTION 602 OF THE PENNSYLVANIA CLEAN STREAMS LAW. THE CLEAN STREAMS LAW PROVIDES FOR
MAY RESULT IN ADMINISTRATIVE, CIVIL, AND/OR CRIMINAL PENALTIES BEING INSTITUTED BY THE DEPARTMENT AS
CONSTRUCTION SITE, OR FAILURE TO TAKE IMMEDIATE CORRECTIVE ACTION TO RESOLVE FAILURE OF E&S BMPS
FAILURE TO CORRECTLY INSTALL E&S BMPS, FAILURE TO PREVENT SEDIMENT-LADEN RUNOFF FROM LEAVING THE 34.
SCHEDULE A FINAL INSPECTION.
AREAS, THE OWNER AND/OR OPERATOR SHALL CONTACT THE LOCAL CONSERVATION DISTRICT OR PADEP TO
UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND PERMANENT STABILIZATION OF ALL DISTURBED 33.
OF DISTURBED AREAS, SUCH REMOVAL/CONVERSIONS SHOULD BE DONE ONLY DURING THE GERMINATING SEASON.
OR CONVERSION OF THE BMPS SHALL BE STABILIZED IMMEDIATELY. IN ORDER TO ENSURE RAPID REVEGETATION
TO PERMANENT POST CONSTRUCTION STORMWATER MANAGEMENT BMPS. AREAS DISTURBED DURING REMOVAL
AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED, TEMPORARY E&S BMPS MUST BE REMOVED OR CONVERTED 32.
INSPECTION PRIOR TO REMOVAL/CONVERSION OF THE E&S BMPS.
AREAS, THE OWNER AND/OR OPERATOR SHALL CONTACT THE LOCAL CONSERVATION DISTRICT OR PADEP FOR AN
UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND PERMANENT STABILIZATION OF ALL DISTURBED 31.
STABILIZED OR UNTIL THEY ARE REPLACED BY ANOTHER BMP APPROVED BY THE DEPARTMENT.
E&S BMPS MUST REMAIN FUNCTIONAL AS SUCH UNTIL ALL AREAS TRIBUTARY TO THEM ARE PERMANENTLY 30.
FILL SLOPES SHALL BE CAPABLE OF RESISTING FAILURE DUE TO SLUMPING, SLIDING, OR OTHER MOVEMENTS.
PERMANENT NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST ACCELERATED EROSION. CUT AND
PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM, PERENNIAL 70% VEGETATIVE COVER OR OTHER 29.
ACCORDANCE WITH THE PERMANENT STABILIZATION SPECIFICATIONS.
SPECIFICATIONS. THOSE AREAS WHICH WILL NOT BE REACTIVATED WITHIN 1 YEAR SHALL BE STABILIZED IN
REACTIVATED WITHIN 1 YEAR, MAY BE STABILIZED IN ACCORDANCE WITH THE TEMPORARY STABILIZATION
BLANKETING SHALL BE APPLIED AS DESCRIBED IN THE PLAN. AREAS NOT AT FINISHED GRADE, WHICH WILL BE
OPERATOR SHALL STABILIZE ALL DISTURBED AREAS. DURING NON-GERMINATING MONTHS, MULCH OR PROTECTIVE
IMMEDIATELY AFTER EARTH DISTURBANCE ACTIVITIES CEASE IN ANY AREA OR SUBAREA OF THE PROJECT, THE 28.
THE STANDARDS OF THIS PLAN.
A SURFACE WATER, OR AS OTHERWISE SHOWN ON THE PLAN DRAWINGS, SHALL BE BLANKETED ACCORDING TO
SLOPES IN COMPETENT BEDROCK AND ROCK FILLS NEED NOT BE VEGETATED. SEEDED AREAS WITHIN 50 FEET OF
ALL GRADED AREAS SHALL BE PERMANENTLY STABILIZED IMMEDIATELY UPON REACHING FINISHED GRADE. CUT 27.
STANDARD SPECIFICATION FOR SUBSURFACE DRAIN OR OTHER APPROVED METHOD.
SEEPS OR SPRINGS ENCOUNTERED DURING CONSTRUCTION SHALL BE HANDLED IN ACCORDANCE WITH THE 26.
FILLS SHALL NOT BE PLACED ON SATURATED OR FROZEN SURFACES.25.
FILLS.
FROZEN MATERIALS OR SOFT, MUCKY, OR HIGHLY COMPRESSIBLE MATERIALS SHALL NOT BE INCORPORATED INTO 24.
OBJECTIONABLE MATERIALS THAT WOULD INTERFERE WITH OR PREVENT CONSTRUCTION OF SATISFACTORY FILLS.
FILL MATERIALS SHALL BE FREE OF FROZEN PARTICLES, BRUSH, ROOTS, SOD, OR OTHER FOREIGN OR 23.
ALL EARTHEN FILLS SHALL BE PLACED IN COMPACTED LAYERS NOT TO EXCEED 9 INCHES IN THICKNESS.22.
COMPACTED IN ACCORDANCE WITH LOCAL REQUIREMENTS OR CODES.
OTHER RELATED PROBLEMS. FILL INTENDED TO SUPPORT BUILDINGS, STRUCTURES AND CONDUITS, ETC. SHALL BE
ALL FILLS SHALL BE COMPACTED AS REQUIRED TO REDUCE EROSION, SLIPPAGE, SETTLEMENT, SUBSIDENCE OR 21.
HAY OR STRAW MULCH MUST BE APPLIED AT 3.0 TONS PER ACRE.20.
MINIMUM OF 2 INCHES OF TOPSOIL.
MINIMUM 4 INCHES OF TOPSOIL IN PLACE PRIOR TO SEEDING AND MULCHING. FILL OUTSLOPES SHALL HAVE A
INCHES ON COMPACTED SOILS - PRIOR TO PLACEMENT OF TOPSOIL. AREAS TO BE VEGETATED SHALL HAVE A
AREAS WHICH ARE TO BE TOPSOILED SHALL BE SCARIFIED TO A MINIMUM DEPTH OF 3 TO 5 INCHES - 6 TO 12 19.
DRAWINGS.
ALL SEDIMENT REMOVED FROM BMPS SHALL BE DISPOSED OF IN THE MANNER DESCRIBED ON THE PLAN 18.
PROJECT DISTURBANCE
PROJECT DISTURBANCE = 0.10 ACRES
URBAN LAND-UDULTS COMPLEX
MAP UNIT NAME
SYMBOL
MAP UNIT
UU
SOILS LEGEND
SYMBOL
MAP UNIT
UU
SOIL LIMITATIONS AND RATINGS
AND STREETS
LOCAL ROADS
NOT RATED
SOURCE
ROADFILL
NOT RATED
SOURCE
TOPSOIL
NOT RATED
RATING
HYDRIC
SOILS INFORMATION, LIMITATIONS AND RESOLUTIONS
LOCATION MAP
NTS
WATER.
THE SEDIMENT BE WASHED, SHOVELED, OR SWEPT INTO ANY ROADSIDE DITCH, STORM SEWER, OR SURFACE
BY THE END OF EACH WORK DAY AND DISPOSED IN THE MANNER DESCRIBED IN THIS PLAN. IN NO CASE SHALL
SEDIMENT TRACKED ONTO ANY PUBLIC ROADWAY OR SIDEWALK SHALL BE RETURNED TO THE CONSTRUCTION SITE 17.
OFFICIALS AT THE TIME OF INSPECTION.
THEY WERE CORRECTED SHALL BE MAINTAINED ON THE SITE AND BE MADE AVAILABLE TO REGULATORY AGENCY
A LOG SHOWING DATES THAT E&S BMPS WERE INSPECTED AS WELL AS ANY DEFICIENCIES FOUND AND THE DATE 16.
REPLACEMENT BMPS, OR MODIFICATIONS OF THOSE INSTALLED WILL BE REQUIRED.
REMULCHING AND RENETTING MUST BE PERFORMED IMMEDIATELY. IF E&S BMPS FAIL TO PERFORM AS EXPECTED, REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR, REPLACEMENT, REGRADING, RESEEDING, INSPECTIONS OF ALL E&S BMPS AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND
UNTIL THE SITE IS STABILIZED, ALL E&S BMPS MUST BE MAINTAINED PROPERLY. MAINTENANCE MUST INCLUDE 15.
NOT BE DISTURBED IN 4 DAYS.
THE CONTRACTOR MUST IMPLEMENT TEMPORARY STABILIZATION MEASURES IN ANY DISTURBED AREA THAT WILL 14.
THIS PLAN, OVER UNDISTURBED VEGETATED AREAS.
ALL PUMPING OF WATER FROM ANY WORK AREA SHALL BE DONE ACCORDING TO THE PROCEDURE DESCRIBED IN 13.
OF A REGULATED SUBSTANCE BUT QUALIFYING AS CLEAN FILL DUE TO ANALYTICAL TESTING.
FP-001 MUST BE RETAINED BY THE PROPERTY OWNER FOR ANY FILL MATERIAL AFFECTED BY A SPILL OR RELEASE
THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ANY MATERIAL BROUGHT ON SITE IS CLEAN FILL. FORM 12.
PRIOR TO BEING ACTIVATED.
ALL OFF-SITE WASTE AND BORROW AREAS MUST HAVE AN E&S PLAN APPROVED BY PADEP FULLY IMPLEMENTED 11.
BURNED, BURIED, DUMPED, OR DISCHARGED AT THE SITE.
SEQ., 271.1, AND 287.1 ET. SEQ. NO BUILDING MATERIALS, WASTES, OR UNUSED BUILDING MATERIALS SHALL BE
ACCORDANCE WITH THE DEPARTMENT'S SOLID WASTE MANAGEMENT REGULATIONS AT 25 PA. CODE 260.1 ET
ALL BUILDING MATERIALS AND WASTES MUST BE REMOVED FROM THE SITE AND RECYCLED OR DISPOSED OF IN 10.
THE REGIONAL OFFICE OF THE DEPARTMENT.
POTENTIAL FOR EROSION AND SEDIMENT POLLUTION AND NOTIFY THE LOCAL CONSERVATION DISTRICT AND/OR
EROSION AND/OR SEDIMENT POLLUTION, THE OPERATOR SHALL IMPLEMENT APPROPRIATE BMPS TO MINIMIZE THE
IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING THE POTENTIAL FOR ACCELERATED 9.
FLATTER.
THE PLAN DRAWINGS. STOCKPILE HEIGHTS MUST NOT EXCEED 35 FEET. STOCKPILE SLOPES MUST BE 2H:1V OR
THAT ARE TO BE STABILIZED BY VEGETATION. EACH STOCKPILE SHALL BE PROTECTED IN THE MANNER SHOWN ON
ON THE PLAN MAP(S) IN THE AMOUNT NECESSARY TO COMPLETE THE FINISH GRADING OF ALL EXPOSED AREAS
TOPSOIL REQUIRED FOR THE ESTABLISHMENT OF VEGETATION SHALL BE STOCKPILED AT THE LOCATION(S) SHOWN 8.
CLEARING AND GRUBBING OPERATIONS BEGIN.
BOUNDARIES SHOWN ON THE PLAN MAPS. THESE AREAS MUST BE CLEARLY MARKED AND FENCED OFF BEFORE
AT NO TIME SHALL CONSTRUCTION VEHICLES BE ALLOWED TO ENTER AREAS OUTSIDE THE LIMIT OF DISTURBANCE 7.
DESCRIBED IN THIS E&S PLAN.
SPECIFIED BY THE BMP SEQUENCE FOR THAT STAGE OR PHASE HAVE BEEN INSTALLED AND ARE FUNCTIONING AS
COMMENCE IN ANY STAGE OR PHASE OF THE PROJECT UNTIL THE E&S BEST MANAGEMENT PRACTICES (BMPS)
OF THE CONSTRUCTION SEQUENCE. GENERAL SITE CLEARING, GRUBBING AND TOPSOIL STRIPPING MAY NOT
CLEARING, GRUBBING, AND TOPSOIL STRIPPING SHALL BE LIMITED TO THOSE AREAS DESCRIBED IN EACH STAGE 6.
VEGETATION, ROOTS AND OTHER OBJECTIONABLE MATERIAL.
AREAS TO BE FILLED SHOULD BE CLEARED, GRUBBED, AND STRIPPED OF TOPSOIL TO REMOVE TREES, 5.
CONSERVATION DISTRICT OR PADEP PRIOR TO IMPLEMENTATION.
PLAN DRAWINGS. DEVIATION FROM THAT SEQUENCE MUST BE APPROVED IN WRITING FROM THE LOCAL
ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE WITH THE SEQUENCE PROVIDED ON THE 4.
THE LOCATION OF EXISTING UNDERGROUND UTILITIES.
PREVIOUSLY UNMARKED, THE PENNSYLVANIA ONE CALL SYSTEM INC. SHALL BE NOTIFIED AT 1-800-242-1776 FOR
AT LEAST 3 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE ACTIVITIES, OR EXPANDING INTO AN AREA 3.
AN ON-SITE PRECONSTRUCTION MEETING.
AND/OR A REPRESENTATIVE FROM THE PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION (PADEP) TO
MUNICIPAL OFFICIALS, THE E&S PLAN PREPARER, A REPRESENTATIVE FROM THE LOCAL CONSERVATION DISTRICT
GRUBBING, THE OWNER AND/OR OPERATOR SHALL INVITE ALL CONTRACTORS, THE LANDOWNER, APPROPRIATE
AT LEAST 7 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE ACTIVITIES, INCLUDING CLEARING AND 2.
SUBMITTAL OF THOSE CHANGES FOR REVIEW AND APPROVAL AT ITS DISCRETION.
PLAN PRIOR TO IMPLEMENTATION OF THOSE CHANGES. THE REVIEWING AGENCY MAY REQUIRE A WRITTEN
PROJECT SITE AT ALL TIMES. THE REVIEWING AGENCY SHALL BE NOTIFIED OF ANY CHANGES TO THE APPROVED
APPROVED DRAWINGS (STAMPED, SIGNED AND DATED BY THE REVIEWING AGENCY) MUST BE AVAILABLE AT THE
ACCORDANCE WITH THE APPROVED EROSION AND SEDIMENTATION CONTROL (E&S) PLAN. A COPY OF THE
ALL EARTH DISTURBANCES, INCLUDING CLEARING AND GRUBBING AS WELL AS CUTS AND FILL SHALL BE DONE IN 1.
JCK JCK KJS
PROJECT LOCATION
10/16/2025
Copyright 2024, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of
Date:Scale: Project No.: Sheet No.:AS NOTED 7/24/2024 32020.00Drawn: Designed: Checked: OF
570-622-4055
Pottsville, PA 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Girardville Borough & Butler Township, Schuylkill County, Pennsylvania
OVER MAHANOY CREEK
SUPERSTRUCTURE REPLACEMENT
JULIA STREET (T-652)
U
S E
R C
F G
U
S E
R
D
A T
E
T
IM
E
F
IL
E
P E
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE081136
JOHN C. KNECHT
72 7
CONSTRUCTION SEQUENCE
THOSE AREAS DESCRIBED IN EACH STAGE.
SHALL BE COMPLETED BEFORE ANY FOLLOWING STAGE IS INITIATED. CLEARING AND GRUBBING SHALL BE LIMITED TO
ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE WITH THE FOLLOWING SEQUENCE. EACH STAGE
MOVEMENTS.
RESIST ACCELERATED EROSION AND SUBSURFACE CHARACTERISTICS SUFFICIENT TO RESIST SLIDING AND OTHER
PERENNIAL VEGETATIVE COVER OR OTHER PERMANENT NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO
BE CONSIDERED TO HAVE ACHIEVED FINAL STABILIZATION WHEN IT HAS A MINIMUM UNIFORM 70 PERCENT
REMOVED. AREAS DISTURBED DURING REMOVAL OF THE BMPS MUST BE STABILIZED IMMEDIATELY. AN AREA SHALL
AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED, TEMPORARY EROSION AND SEDIMENT BMPS MUST BE 8.
STABILIZE ALL REMAINING DISTURBED AREAS.7.
COMPLETE ALL REMAINING ROADWAY IMPROVEMENTS.6.
BACKFILL AND STABILIZE SLOPES.5.
CONSTRUCT PROPOSED SUPERSTRUCTURE.4.
REMOVE EXISTING SUPERSTRUCTURE. REMOVE ANY MATERIALS THAT FALL INTO THE STREAM IMMEDIATELY.3.
CONSTRUCTION ENTRANCE AND CONCRETE WASHOUT.
SEDIMENT DURING THESE OPERATIONS. TEMPORARY CONTROLS INCLUDE, COMPOST FILTER SOCK, ROCK
PRIOR TO THE START OF STRUCTURE WORK, PLACE TEMPORARY EROSION CONTROL FEATURES TO CONTROL 2.
ABOVE GROUND ELEVATION. DO NOT CONDUCT TREE REMOVAL FROM MAY 15 TO AUGUST 15.
DETOUR TRAFFIC AND CLEAR THE SITE AS REQUIRED. THIS WORK INCLUDES REMOVAL OF TREES AND BRUSH 1.
CONSTRUCTION SEQUENCE
EROSION AND SEDIMENTATION POLLUTION CONTROL
JCK JCK KJS
Copyright 2024, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of
Date:Scale: Project No.: Sheet No.:AS NOTED 7/24/2024 32020.00Drawn: Designed: Checked: OF
570-622-4055
Pottsville, PA 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Girardville Borough & Butler Township, Schuylkill County, Pennsylvania
OVER MAHANOY CREEK
SUPERSTRUCTURE REPLACEMENT
JULIA STREET (T-652)
U
S E
R C
F G
U
S E
R
D
A T
E
T
IM
E
F
IL
E
P E
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE081136
JOHN C. KNECHT
73 7
DETAILS
EROSION AND SEDIMENTATION POLLUTION CONTROL
NOT TO SCALE
COMPOST FILTER SOCK
SPREAD AS A SOIL SUPPLEMENT.
IN PLACE AND VEGETATED OR REMOVED. IN THE LATTER CASE, THE MESH SHALL BE CUT OPEN AND THE MULCH
UPON STABILIZATION OF THE AREA TRIBUTARY TO THE SOCK, STAKES SHALL BE REMOVED. THE SOCK MAY BE LEFT 7.
POLYPROPYLENE SOCKS SHALL BE REPLACED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.
BIODEGRADABLE FILTER SOCKS SHALL BE REPLACED AFTER 6 MONTHS; PHOTODEGRADABLE SOCKS AFTER 1 YEAR. 6.
ACCORDING TO MANUFACTURER'S SPECIFICATIONS OR REPLACED WITHIN 24 HOURS OF INSPECTION.
SOCKS SHALL BE INSPECTED WEEKLY AND AFTER EACH RUNOFF EVENT. DAMAGED SOCKS SHALL BE REPAIRED 5.
AND DISPOSED IN THE MANNER DESCRIBED ELSEWHERE IN THE PLAN.
ACCUMULATED SEDIMENT SHALL BE REMOVED WHEN IT REACHES HALF THE ABOVEGROUND HEIGHT OF THE SOCK 4.
TRAFFIC SHALL NOT BE PERMITTED TO CROSS FILTER SOCKS.3.
DOWNSLOPE OF THE SOCK IF SO SPECIFIED BY THE MANUFACTURER.
AND SEDIMENT POLLUTION CONTROL PROGRAM MANUAL (363-2134-008). STAKES MAY BE INSTALLED IMMEDIATELY
SOCK SHALL NOT EXCEED THAT IN THE EROSION AND SEDIMENT CONTROL REPORT AND/OR THE PADEP EROSION
AT LEAST 8 FEET UP SLOPE AT 45 DEGREES TO THE MAIN SOCK ALIGNMENT. MAXIMUM SLOPE LENGTH ABOVE ANY
COMPOST FILTER SOCK SHALL BE PLACED AT EXISTING LEVEL GRADE. BOTH ENDS OF THE SOCK SHALL BE EXTENDED 2.
SHOWN IN TABLE BELOW.
SOCK FABRIC SHALL MEET STANDARDS AS SHOWN IN TABLE BELOW. COMPOST SHALL MEET THE STANDARDS AS 1.
NOTES:
COMPOST SOCK FABRIC MINIMUM SPECIFICATIONS
TWO-PLY SYSTEMS
SOCK FABRICS COMPOSED OF BURLAP MAY BE USED ON PROJECTS LASTING 6 MONTHS OR LESS
MATERIAL TYPE
CHARACTERISTICS
MATERIAL
DIAMETERS
SOCK
MESH OPENING
STRENGTH
TENSILE
(ASTM-G-155)
STRENGTH
ORIGINAL
STABILITY %
ULTRAVIOLET
LONGEVITY
FUNCTIONAL
MINIMUM
3 MIL HDPE
DEGRADABLE
PHOTO-
18"
12"
3/8"
1000 HR
23% AT
6 MONTHS
5 MIL HDPE
DEGRADABLE
PHOTO-
32"
24"
18"
12"
3/8"
26 PSI
1000 HR
23% AT
9 MONTHS
5 MIL HDPE
DEGRADABLE
BIO-
32"
24"
18"
12"
3/8"
26 PSI
6 MONTHS
(MFPP)
POLYPROPYLENE
MULTI-FILAMENT
DEGRADABLE
PHOTO-
32"
24"
18"
12"
3/8"
44 PSI
1000 HR
100% AT
1 YEAR
(HDMFPP)
POLYPROPYLENE
MULTI-FILAMENT
HEAVY DUTY
DEGRADABLE
PHOTO-
32"
24"
18"
12"
1/8"
202 PSI
1000 HR
100% AT
2 YEARS
INNER CONTAINMENT NETTING
OUTER FILTRATION MESH
HDPE BIAXIAL NET
CONTINUOUSLY WOUND
FUSION-WELDED JUNCTURES
3/4" X 3/4" MAX APERTURE SIZE
MECHANICALLY FUSED VIA NEEDLE PUNCH)
(WOVEN LAYER AND NON-WOVEN FLEECE
COMPOSITE POLYPROPYLENE FABRIC
3 /16" MAX APERTURE SIZE
ALTERNATIVE.
TABLE BELOW. THE STANDARDS CONTAINED IN THE PENNDOT PUBLICATION 408 ARE AN ACCEPTABLE
THE PHYSICAL PARAMETERS OF THE COMPOST SHOULD COMPLY WITH THE STANDARDS AS SHOWN IN THE
ACCEPTABLE AS THE ORGANIC COMPONENT OF THE MIX.
AND BARK CHIPS, GROUND CONSTRUCTION DEBRIS OR REPROCESSED WOOD PRODUCTS ARE NOT
COMPOST PRODUCT SHOULD NOT RESEMBLE THE RAW MATERIAL FROM WHICH IT WAS DERIVED. WOOD
ODORS AND SHOULD BE SEASONABLY FREE (<1% BY DRY WEIGHT) OF MAN-MADE FOREIGN MATTER. THE
COMPOST SHOULD BE AEROBICALLY COMPOSTED. THE COMPOST SHOULD POSSESS NO OBJECTIONABLE
AGRICULTURE, FOOD, STUMP GRINDINGS, AND YARD OR WOOD/BARK ORGANIC MATTER SOURCES. THE
COMPOST SHOULD BE A WELL DECOMPOSED, WEED-FREE ORGANIC MATTER DERIVED FROM
COMPOST STANDARDS
SOLUBLE SALT CONCENTRATION
PARTICLE SIZE
MOISTURE CONTENT
pH
ORGANIC PORTION
ORGANIC MATTER CONTENT
5.0 DS/M (MMHOS/CM) MAXIMUM
30% - 50% PASS THROUGH 3/8" SCREEN
30% - 60%
5.5 - 8.5
FIBROUS AND ELONGATED
25% - 100% (DRY WEIGHT BASIS)
SECTION VIEW
PLAN VIEW
AREA
UNDISTURBED
UNDISTURBED AREADISTURBED AREA
AREA
DISTURBED
M
IN
BLOWN / PLACED FILTER MEDIA COMPOST FILTER SOCK
2" x 2" WOODEN STAKES PLACED 10' OC
PLACED 10' OC (TYP)
2" x 2" WOODEN STAKES COMPOST FILTER SOCK
F L O
W F L O
W
CONTOURS
EXISTING
NOT TO SCALE
COMPOST SOCK WASHOUT
HEIGHT.
FILTER SOCK MAY BE STACKED ONTO DOUBLE 24" DIAMETER SOCKS IN PYRAMIDAL CONFIGURATION FOR ADDED
COMPOST SOCKS MAY BE STACKED AND STAKED SO AS TO FORM A TRIANGULAR CROSS SECTION. 18-INCH DIAMETER
PLASTIC LINERS SHOULD BE REPLACED WITH EACH CLEANING OF THE WASHOUT FACILITY.
ACCUMULATED MATERIALS SHOULD BE REMOVED WHEN THEY REACH 75% CAPACITY.
IMMEDIATELY.
INSPECT WASHOUT FACILITIES DAILY. DEACTIVATE AND REPAIR OR REPLACE DAMAGE OR LEAKING WASHOUTS
OF WHEN THEY REACH THE CLEANOUT LEVEL.
THAT THEY ARE WATERTIGHT, AND APPROPRIATELY SIZED. ACCUMULATED MATERIALS MUST BE PROPERLY DISPOSED
ENSURE THAT THE CONTAINERS ARE INTENDED BY THE MANUFACTURER FOR USE AS CONCRETE WASHOUT BMPS, PREFABRICATED WASHOUT CONTAINERS MAY BE USED AS A SUITABLE ALTERNATIVE. CARE SHOULD BE TAKEN TO
NOTES:
SECTION VIEW
PLAN VIEW
SPACED 5' OC (TYP)
2" x 2" x 36" WOOD STAKES
FILTER RING
ON UPSLOPE SIDE OF
SOCK 4' MIN OVERLAP
24" COMPOST FILTER
INTO FILTER RING
WASHOUT WATER
DIRECT CONCRETE
M
IN
SPACED 5' OC (TYP)
2" x 2" x 36" WOOD STAKES
FILTER RING HEIGHT
WASHOUT WATER IS 50% OF
MAXIMUM DEPTH OF CONCRETE
MIN 10 MIL THICKNESS
PLASTIC SHEETING,
FILTER SOCK
24" COMPOST
Copyright 2024, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of
Date:Scale: Project No.: Sheet No.:AS NOTED 7/24/2024 32020.00Drawn: Designed: Checked: OF
570-622-4055
Pottsville, PA 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Girardville Borough & Butler Township, Schuylkill County, Pennsylvania
OVER MAHANOY CREEK
SUPERSTRUCTURE REPLACEMENT
JULIA STREET (T-652)
U
S E
R C
F G
U
S E
R
D
A T
E
T
IM
E
F
IL
E
P E
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE081136
JOHN C. KNECHT
74 7
DETAILS
EROSION AND SEDIMENTATION POLLUTION CONTROL
NOT TO SCALE
ROCK CONSTRUCTION ENTRANCE
DITCH BEING CROSSED.
SPECIFIED BY MANUFACTURER IS NOT OTHERWISE PROVIDED. PIPE SHALL BE SIZED APPROPRIATELY FOR SIZE OF
MOUNTABLE BERM SHALL BE INSTALLED WHEREVER OPTIONAL CULVERT PIPE IS USED AND PROPER PIPE COVER AS 3.
CONSTRUCTION ENTRANCE.
RUNOFF SHALL BE DIVERTED FROM ROADWAY TO A SUITABLE SEDIMENT REMOVAL BMP PRIOR TO ENTERING ROCK 2.
OF ENTRANCE.
REMOVE TOPSOIL PRIOR TO INSTALLATION OF ROCK CONSTRUCTION ENTRANCE. EXTEND ROCK OVER FULL WIDTH 1.
NOTES:
PROFILE
PLAN VIEW
IS NOT ACCEPTABLE.
ROADWAY OR SWEEPING THE DEPOSITS INTO ROADWAY DITCHES, SEWERS, CULVERTS, OR OTHER DRAINAGE COURSES
ENTRANCE BY 50 FOOT INCREMENTS UNTIL CONDITION IS ALLEVIATED OR INSTALL WASH RACK. WASHING THE
EXCESSIVE AMOUNTS OF SEDIMENT ARE BEING DEPOSITED ON ROADWAY, EXTEND LENGTH OF ROCK CONSTRUCTION
DEPOSITED ON PAVED ROADWAYS SHALL BE REMOVED AND RETURNED TO THE CONSTRUCTION SITE IMMEDIATELY. IF
DIMENSIONS BY ADDING ROCK. A STOCKPILE SHALL BE MAINTAINED ON SITE FOR THIS PURPOSE. ALL SEDIMENT
MAINTENANCE: ROCK CONSTRUCTION ENTRANCE THICKNESS SHALL BE CONSTANTLY MAINTAINED TO THE SPECIFIED
PROVIDE PROPER COVER OVER PIPE
* MOUNTABLE BERM USED TO
M
IN
M
IN
M
IN
50' MIN
3'
ROADWAY
EXISTING
ROADWAY
EXISTING
EXISTING GROUND
GEOTEXTILE
MIN 8" AASHTO #1
EARTH FILL
PIPE AS NECESSARY
(6" MIN) *
MOUNTABLE BERM
AOS% RETAINED
UV RESISTANCE
MULLEN BURST
PUNCTURE
GRAB TENSILE
AVG WIDE WIDTH STRENGTH
PROPERTY
ASTM-D-4751
ASTM-D-4355
ASTM-D-3786
ASTM-D-4833
ASTM-D-4632
ASTM-D-4884
TEST METHOD
80 SIEVE
70%
350 PSI
110 LB
205 LB
60 LB/IN
MINIMUM STANDARD
NOTES:
FILTER BAG
WELL VEGETATED, GRASSY AREA
DISCHARGE HOSE
PUMP
CLAMPS
ELEVATION VIEW
NOT TO SCALE
PUMPED WATER FILTER BAG
STANDARDS:
BAGS SHALL BE MADE FROM WOVEN GEOTEXTILES THAT MEET THE FOLLOWING
CAPABLE OF TRAPPING PARTICLES LARGER THAN 150 MICRONS. HIGH VOLUME FILTER
SEWN WITH HIGH STRENGTH, DOUBLE STITCHED "J" TYPE SEAMS. THEY SHALL BE
GEOTEXTILE MATERIAL LOW VOLUME FILTER BAGS SHALL BE MADE FROM NON-WOVEN 1.
SHALL CEASE IMMEDIATELY AND NOT RESUME UNTIL THE PROBLEM IS CORRECTED.
DETECTED, PUMPING FILTER BAGS SHALL BE INSPECTED DAILY. IF ANY PROBLEM IS 7.
FLOATING AND SCREENED.
SPECIFIED BY THE MANUFACTURER, WHICHEVER IS LESS. PUMP INTAKES SHALL BE
MAXIMUM THE PUMPING RATE SHALL BE NO GREATER THAN 750 GPM OR 1/2 THE 6.
RECOMMENDED FOR THIS PURPOSE.
SPECIFIED BY THE MANUFACTURER AND SECURELY CLAMPED. A PIECE OF PVC PIPE IS
THE MANNER THE PUMP DISCHARGE HOSE SHALL BE INSERTED INTO THE BAGS IN 5.
WATER OR WHERE GRASSY AREA IS NOT AVAILABLE.
LOCATED IN HQ OR EV WATERSHEDS, WITHIN 50 FEET OF ANY RECEIVING SURFACE
COMPOST BERM OR COMPOST FILTER SOCK SHALL BE INSTALLED BELOW BAGS
INSTALLATIONS. NO DOWNSLOPE SEDIMENT BARRIER IS REQUIRED FOR MOST 4.
REDUCE SLOPE STEEPNESS.
NON-ERODIBLE AND NON-POLLUTING MATERIAL MAY BE PLACED UNDER THE BAG TO
SLOPES GREATER THAN 5%. FOR SLOPES EXCEEDING 5%, CLEAN ROCK OR OTHER
FILTER STONE TO INCREASE DISCHARGE CAPACITY. BAGS SHALL NOT BE PLACED ON
UNDERLAYMENT AND FLOW PATH SHALL BE PROVIDED. BAGS MAY BE PLACED ON
STABLE, EROSION RESISTANT AREAS. WHERE THIS IS NOT POSSIBLE, A GEOTEXTILE
DISCHARGE ONTO BAGS SHALL BE LOCATED IN WELL-VEGETATED (GRASSY) AREA, AND 3.
ALREADY ATTACHED.
ON STRAPS TO FACILITATE REMOVAL UNLESS BAGS COME WITH LIFTING STRAPS
REPLACEMENT OF THOSE THAT HAVE FAILED OR ARE FILLED. BAGS SHALL BE PLACED
THEY BECOME 1/2 FULL OF SEDIMENT. SPARE BAGS SHALL BE KEPT AVAILABLE FOR
DISPOSAL PURPOSES SHALL BE PROVIDED. FILTER BAGS SHALL BE REPLACED WHEN
REQUIRED FOR A SUITABLE MEANS OF ACCESSING THE BAG WITH MACHINERY 2.
ITEM NO. 0867-0012 COMPOST FILTER SOCK, 12" DIAMETER
ITEM NO. 0855-0004 REPLACEMENT PUMPED WATER FILTER BAG
ITEM NO. 0855-0003 PUMPED WATER FILTER BAG
FLOW
AREA
VEGETATED
WELL
AREA
VEGETATED
WELL
AREA
VEGETATED
WELL
AREA
VEGETATED
WELL
TOP VIEW
STRAPS
HEAVY DUTY LIFTING
SEWN IN SPOUT
METAL CLAMPS
FASTENED WITH
AND SECURELY
MANUFACTURER
AS SPECIFIED BY
HOSE TO BE INSERTED
CLAMPS
PUMP
INTAKE HOSE
DISCHARGE HOSE
IS REQUIRED
ONLY WHEN LEVELING
AGGREGATE TO BE USED
NO. 57 COARSE
FILTER SOCK
12" COMPOST
SURROUND BAG)
(COMPLETELY
FILTER SOCK
12" COMPOST
STAKE
SURROUND BAG)
(COMPLETELY
FILTER SOCK
12" COMPOST
STAKE
CLAMPS
INTAKE HOSE
JCK JCK
NTS
FENCE (SEE DETAIL)
HEIGHT OR EQUIVALENT SILT
COMPOST FILTERSOCK, 12"
UNDISTURBED AREA
FILL THIS AREA
MATERIAL SHALL NOT
STOCKPILE CONTROL DETAIL
FENCE (SEE DETAIL)
HEIGHT OR EQUIVALENT SILT
COMPOST FILTERSOCK, 12"
SECTION
2 (MAX)
SECTION
SEE
DETAIL
ANCHORING POST SEE
F
E E
T
M A
X
MATERIAL
STOCKPILE
MATERIAL
STOCKPILE
6'-0"
MIN
KJS
Copyright 2024, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of
Date:Scale: Project No.: Sheet No.:AS NOTED 7/24/2024 32020.00Drawn: Designed: Checked: OF
570-622-4055
Pottsville, PA 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Girardville Borough & Butler Township, Schuylkill County, Pennsylvania
OVER MAHANOY CREEK
SUPERSTRUCTURE REPLACEMENT
JULIA STREET (T-652)
U
S E
R C
F G
U
S E
R
D
A T
E
T
IM
E
F
IL
E
P E
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE081136
JOHN C. KNECHT
75 7
DETAILS
EROSION AND SEDIMENTATION POLLUTION CONTROL
NOT TO SCALE
EROSION CONTROL BLANKET INSTALLATION
SHALL BE RESTORED OR REPLACED WITHIN 4 CALENDAR DAYS.
COVERAGE THROUGHOUT THE BLANKETED AREA. DAMAGED OR DISPLACED BLANKETS
UNTIL PERENNIAL VEGETATION IS ESTABLISHED TO A MINIMUM UNIFORM 70%
BLANKETED AREAS SHALL BE INSPECTED WEEKLY AND AFTER EACH RUNOFF EVENT 6.
RECOMMENDATIONS.
THE BLANKET SHALL BE STAPLED IN ACCORDANCE WITH THE MANUFACTURER’S 5.
MAINTAIN DIRECT CONTACT WITH SOIL. DO NOT STRETCH BLANKET.
THROUGHOUT ENTIRE LENGTH. LAY BLANKET LOOSELY AND STAKE OR STAPLE TO
BLANKET SHALL HAVE GOOD CONTINUOUS CONTACT WITH UNDERLYING SOIL 4.
SLOPE SURFACE SHALL BE FREE OF ROCKS, CLODS, STICKS, AND GRASS.3.
PROVIDE ANCHOR TRENCH AT TOE OF SLOPE IN SIMILAR FASHION AS AT TOP OF SLOPE.2.
PLAN DRAWINGS PRIOR TO INSTALLING THE BLANKET.
SEED AND SOIL AMENDMENTS SHALL BE APPLIED ACCORDING TO THE RATES IN THE 1.
NOTE:
GOOD SOIL CONTACT.
STRETCHED; IT MUST MAINTAIN
THE BLANKET SHOULD NOT BE
STYLE). STAPLE SECURELY.
DOWNSLOPE BLANKET (SHINGLE
THE UPSLOPE BLANKET OVERLYING THE
OVERLAP BLANKET ENDS 6" (MIN.) WITH
SLOPE BEING BLANKETED.
FOR STEEPNESS AND LENGTH OF
RECOMMENDED STAPLING PATTERN
REFER TO MANUFACTURER'S
BLANKET.
PRIOR TO INSTALLATION OF
LIME, FERTILIZER, & SEED)
(INCLUDING APPLICATION OF
PREPARE SEED BED
AND COMPACT SOIL.
TRENCH, STAPLE, BACKFILL
ROLL IN 6" x 6" ANCHOR
INSTALL BEGINNING OF
OF WATER FLOW
ROLL BLANKETS IN DIRECTION
STARTING AT TOP OF SLOPE,
AND STAPLED.
OVERLAPPED 4" (MIN.)
BLANKET EDGES
NOT TO SCALE
EROSION CONTROL BLANKET STAPLE PATTERNS
SLOPES FLATTER THAN 3:1
ANCHOR PATTERN FOR
(INCLUDING 3:1)
BETWEEN 3:1 AND 2:1
ANCHOR PATTERN FOR SLOPES
(INCLUDING 2:1)
BETWEEN 2:1 AND 1:1
ANCHOR PATTERN FOR SLOPES
3'-0"
3'-0"
" 4
"3'-0"
1'-6"1'-6"
(TYP)
ANCHORS
(TYP)
ANCHORS
(TYP)
ANCHORS
PLACE 1 ANCHOR/SY
PLACE 1.5 ANCHOR/SY
PLACE 2 ANCHOR/SY
Copyright 2024, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of
Date:Scale: Project No.: Sheet No.:AS NOTED 7/24/2024 32020.00Drawn: Designed: Checked: OF
570-622-4055
Pottsville, PA 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Girardville Borough & Butler Township, Schuylkill County, Pennsylvania
OVER MAHANOY CREEK
SUPERSTRUCTURE REPLACEMENT
JULIA STREET (T-652)
U
S E
R C
F G
U
S E
R
D
A T
E
T
IM
E
F
IL
E
P E
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE081136
JOHN C. KNECHT
76 7
DETAILS
EROSION AND SEDIMENTATION POLLUTION CONTROL
SEED FORMULA SPECIFICATIONS
APPLICATION RATE FOR SLOPES LESS THAN 3:1
STRAW 3 TONS 140 LB 1240 LB
WEEDS, NOT CHOPPED OR FINELY BROKEN
EITHER WHEAT OR OAT STRAW, FREE OF
HAY 3 TONS 140 LB 1240 LB
OTHER NATIVE FORAGE GRASSES
TIMOTHY, MIXED CLOVER AND TIMOTHY OR
WOOD CHIPS 4-6 TONS 185-275 LB 1650-2500 LB
GRASSES AND LEGUMES
MAY PREVENT GERMINATION OF
HYDROMULCH 1 TON 47 LB 415 LB SEE NOTES
SLOPES 3:1 AND GREATER
MULCH BLANKET
EROSION CONTROL
MANUFACTURERS' INSTRUCTIONS
APPLY BLANKET AND ANCHOR PER
SC150 (2:1) OR APPROVED EQUALS
NORTH AMERICAN GREEN S150 (3:1) AND
MULCH APPLICATION RATES
3. THE APPLICATION RATE FOR ANY HYDROMULCH SHOULD BE 2,000 LB/ACRE AT A MINIMUM.
2. WOOD FIBER HYDROMULCH MAY BE APPLIED ON STEEPER SLOPES PROVIDED A TACKIFIER IS USED.
1. SHREDDED PAPER HYDROMULCH SHOULD NOT BE USED ON SLOPES STEEPER THAN 5%.
NOTES:
MULCH TYPE PER ACRE PER 1000 SF PER 1000 SY NOTES
PERMANENT SEEDING APPLICATION RATE
AGRICULTURAL LIME 6 TONS 240 LB 2,480 LB
REQUIRED IN AGRICULTURAL FIELDS
OR AS PER SOIL TEST; MAY NOT BE
10-10-20 FERTILIZER 1,000 LB 25 LB 210 LB
REQUIRED IN AGRICULTURAL FIELDS
OR AS PER SOIL TEST; MAY NOT BE
TEMPORARY SEEDING APPLICATION RATE
AGRICULTURAL LIME
TOPSOIL STOCKPILES
TYPICALLY NOT REQUIRED FOR
SOIL AMENDMENT APPLICATION RATES EQUIVALENTS
BE SUBSTITUTED FOR THE SOIL AMENDMENTS SHOWN IN THE ABOVE TABLE.
A COMPOST BLANKET WHICH MEETS THE STANDARDS OF THE MANUAL MAY 1.
SOIL AMENDMENT PER ACRE PER 1000 SF PER 1000 SY NOTES
10-10-10 FERTILIZER
TOPSOIL STOCKPILES
TYPICALLY NOT REQUIRED FOR
1 TON 40 LB 410 LB
500 LB 12.5 LB 100 LB
JCK JCK KJS
TABLE B
T
L
N
B
FORMULA
TEMPORARY SEEDING
LOW MAINTENANCE, FLAT AREAS
SLOPES STEEPER THAN 3:1
NON-STEEP, HIGHLY MAINTAINED SURFACES, LAWN
APPLICATION
SCHEDULE OF SEEDING AND SOIL SUPPLEMENTS
SEEDING SEASON DATES:
MULCHING RATE:
MULCH TYPE:
LIMING RATE:
FERTILIZER APPL RATE
FERTILIZER TYPE:
APPLICATION RATE:
% PURE LIVE SEED:
SPECIES:
/15 TO 6/1 & 8/1 TO 10/153
HAY
6.0
SEE TABLE A
FORMULA T(TEMPORARY)
LB/1000 SY
LB/1000 SY
LB/1000 SY
(X-X-X)
LB/1000 SY
10-20-20
AND
38-0-0 UREAFORM
OR
59 TO 50 AS DIRECTED
32-0-0 TO 38-0-0 SULFER COATED UREA
OR
31-0-0
SEEDING SEASON DATES:
ANCHORING METHOD:
RATE OF ANCHOR MATERIAL APPL:
ANCHOR MATERIAL:
MULCHING RATE:
MULCH TYPE:
LIMING RATE:
FERTILIZER APPL RATE
FERTILIZER TYPE:
APPLICATION RATE:
% PURE LIVE SEED:
SPECIES:(PERMANENT, <3:1 SLOPES)
LB/1000 SY
LB/1000 SY
LB/1000 SY
LB/1000 SY
LB/1000 SY
(X-X-X)
LB/1000 SY
/15 TO 6/1 & 8/1 TO 10/153
PER MANUFACTURERS' INSTRUCTIONS
STRAW
B: 42.0 ~ L: 48.0
SEE TABLE A
FORMULA B ~ FORMULA L
10-20-20
AND
38-0-0 UREAFORM
OR
59 TO 50 AS DIRECTED
32-0-0 TO 38-0-0 SULFER COATED UREA
OR
31-0-0
RECYCLED CELLULOSE FIBER
AND
WOOD FIBER
OR
PER MANUFACTURERS' INSTRUCTIONS
NONASPHALTIC EMULSION
OR
PER MANUFACTURERS' INSTRUCTIONS
POLYVINYL ACETATE
OR
RECYCLED CELLULOSE FIBER/WOOD FIBER MIXTURE
SEEDING SEASON DATES:
RATE OF ANCHOR MATERIAL APPL:
ANCHORING METHOD:
ANCHOR MATERIAL:
MULCHING RATE:
MULCH TYPE:
LIMING RATE:
FERTILIZER APPL RATE
FERTILIZER TYPE:
APPLICATION RATE:
% PURE LIVE SEED:
SPECIES:(PERMANENT, SLOPES/SWALES)
LB/1000 SY
LB/1000 SY
LB/1000 SY
LB/1000 SY
(X-X-X)
LB/1000 SY
NURSERY CROPS: ANYTIME ~ NATIVE: 10/15 TO 5/15
PER MANUFACTURERS' INSTRUCTIONS
PER MANUFACTURERS' INSTRUCTIONS
PER MANUFACTURERS' INSTRUCTIONS
PER MANUFACTURERS' INSTRUCTIONS
ROLLED EROSION CONTROL PRODUCT
AS INDICATED BY SOIL TESTS
AS INDICATED BY SOIL TESTS
AS INDICATED BY SOIL TESTS
C: 12.0 ~ N: 8.0 ~ P: 8.0
SEE TABLE A
FORMULA C ~ FORMULA N ~ FORMULA P
FORMULA B RESIDENTIAL MIX:
VARIETY EXCEEDING 50% OF THE TOTAL BLUEGRASS COMPONENT.
COMBINATION OF IMPROVED CERTIFIED VARIETIES WITH NO ONE
KENTUCKY BLUEGRASS MIXTURE (POA PRATENSIS). A
OR SSP COMMUTATE) (IMPROVED AND CERTIFIED)
CREEPING RED FESCUE OR CHEWINGS FESCUE (FESTUCA RUBRA
VARIETY EXCEEDING 50% OF THE TOTAL RYEGRASS COMPONENT.
COMBINATION OF IMPROVED CERTIFIED VARIETIES WITH NO ONE
PERENNIAL RYEGRASS MIXTURE (LOLIUM PERENNE). A
0.15
0.10
0.10
21.0 (105)
12.5 (62.5)
8.5 (42.5)
42.0 (210) TOTAL
2.5
2.5
0.75
0.25
2.5
1.25
0.625
0.625
1.25
6.25
2.5
SHOWY TICK-TREFOIL (DESMODIUM CANADENSE)
PARTRIDGE PEA (CHAMAECRISTA FASCICULATA)
COMMON MILKWEED (ASCLEPIAS SYRIACA)
WHITE AVENS (GEUM CANADENSE)
OX-EYE SUNFLOWER (HELIOPSIS HELIANTHOIDES)
BLACK-EYED SUSAN (RUDBECKIA HIRTA)
ROUNDSEED PANICGRASS (PANICUM SPHAEROCARPUM)
INDIANGRASS
SWITCHGRASS (PANICUM VIRGATUM)
CANADA WILDRYE (ELYMUS CANADENSIS)
LITTLE BLUESTEM (SCHIZACHYRIUM SCOPARIUM)
PURPLE TOP (TRIDENS FLAVUS)
PERMANENT SPECIES
CEREAL RYE (SECALE CEREALE) (FALL)
OATS (AVENA SATIVA) (SPRING)
NURSERY CROPS
0.20
0.20
0.20
0.20
0.20
0.20
0.10
0.10
0.2 (1.0)
0.2 (1.0)
0.06 (0.3)
0.02 (0.1)
0.2 (1.0)
0.32 (1.6)
0.1 (0.5)
0.05 (0.25)
0.05 (0.25)
0.1 (0.5)
0.5 (2.5)
0.2 (1.0)
6 (30)
6 (30)
8 (40.0) TOTALFORMULA N CONSERVATION MIX: *
FORMULA T TEMPORARY GRASS MIX:
CEREAL RYE (SECALE CEREALE) (FALL)
OATS (AVENA SATIVA) (SPRING)
0.1
0.1
6 (30)
6 (30)
6 (30) TOTAL
IF A SPECIES IS UNAVAILABLE IN THIS MIX, SUBSTITUTE BY INCREASING THE PERCENTAGE OF OTHER ITEMS IN THE MIX.*
FORMULA L CLEAR ZONE MIX:
ANNUAL RYEGRASS (LOLIUM MULTIFLORUM)
CERTIFIED)
CREEPING RED FESCUE (FESTUCA RUBRA) (IMPROVED AND
EXCEEDING 50% OF THE TOTAL HARD FESCUE COMPONENT
OF IMPROVED CERTIFIED VARIETIES WITH NO ONE VARIETY
HARD FESCUE MIXTURE (FESTUCA LONGIFOLIA). A COMBINATION
0.10
0.10
0.10
4.8 (24)
16.8 (84)
26.4 (132)
48.0 (240) TOTAL
(LB/ACRE)
LB/1000 SQ YD
SEEDING RATE
WEED SEED
MAX. %
GERMINATIONPURITY
MINIMUM %
FORMULA AND SPECIES
TABLE A
WEIGHT
% BY
7 7
PLAN
EROSION AND SEDIMENT POLLUTION CONTROL
- EXISTING GUIDERAIL
- EDGE OF STREAM
- FLOW DIRECTION
LEGEND
- CONCRETE WASHOUT
- PUMPED WATER FILTER BAG
- ROCK CONSTRUCTION ENTRANCE
- LIMIT OF DISTURBANCE
- COMPOST FILTER SOCK, SIZE INDICATED
- PROPOSED GUIDERAIL
- EXISTING CONTOUR
EXISTING STRUCTURE
MINIMUM UNDERCLEARANCE = 6.72'
HYDRAULIC OPENING = 370 SF
STRUCTURE LENGTH = 53.0'
OUT-TO-OUT WIDTH = 16.4±
ROADWAY WIDTH = 13'±
SKEW = 90°00'00"
CONCRETE ADJ BOX BEAM BRIDGE
SINGLE SPAN NON-COMPOSITE P/S
STA 11+03.00
PROPOSED STRUCTURE
MINIMUM UNDERCLEARANCE = 7.05'
HYDRAULIC OPENING = 355 SF
"2
OUT TO OUT WIDTH = 17'-5
CLEAR ROADWAY WIDTH = 13'-8"
SPAN = 51'-6" (� BRG TO � BRG)
SKEW = 90°00'00"
ON P/S CONCRETE ADJ BOX BEAM BRIDGE
SINGLE SPAN COMPOSITE CONCRETE DECK
STA 11+03.00LD
- DIRECTION OF TRAFFIC
JCK JCK KJS
PLAN VIEW
5 0 5 10 FEET
- PROPERTY LINE
- EXISTING OVERHEAD UTILITIES
- THERE ARE NO IN-STREAM RESTRICTIONS.
REPRODUCTION OF TROUT.
WILD TROUT STREAM, IT IS NOT TROUT STOCKED AND DOES NOT SUPPORT THE NATURAL
THE PA FISH AND BOAT COMMISSION DOES NOT DESIGNATE MAHANOY CREEK AS A CLASS A
- MAHANOY CREEK IS DESIGNATED A WARM WATER FISHERY WITH MIGRATORY FISH (WWF-MF).
NOTES:
- EXISTING 100 YR FLOOD PLAIN
- PROPOSED 100 YR FLOOD PLAIN
WATWAT
N08°23'08"E
10 11 1210
B U
IL
D
IN
G
WVCS
WVCS
WVCS
WVCSWVCS
M A
H A
N
Y
C R
E E
K
" R
CP
24" CMP
SURVEY & CONSTR �
SURVEY & CONSTR �
JULIA STREET
STA AHEAD
STA 11+80.00
END FULL DEPTH
RECONSTRUCTION
BEGIN FULL DEPTH
RECONSTRUCTION
STA 11+29.50
BEGIN FULL DEPTH
RECONSTRUCTION
STA 10+59.00
STA 10+76.50
END FULL DEPTH
RECONSTRUCTION
(TO BE REMOVED BY OTHERS)
EXISTING WATERLINE
UU
UU
Rev Date By Chk'd Description
Copyright 2024, of Alfred Benesch & Company. All rights reserved. This plan and design content is the property of
Date:Scale: Project No.: Sheet No.:AS NOTED 7/24/2024 32020.00Drawn: Designed: Checked: OF
570-622-4055
Pottsville, PA 17901
400 One Norwegian Plaza
Alfred Benesch & Company
Girardville Borough & Butler Township, Schuylkill County, Pennsylvania
OVER MAHANOY CREEK
SUPERSTRUCTURE REPLACEMENT
JULIA STREET (T-652)
U
S E
R C
F G
U S
E R
D A
T E
T
IM
E
F
IL
E
P E
N N
S Y L V A
N I
A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE081136
JOHN C. KNECHT
| 01_ES_GenNotes |
| 02_ES_ConSeq |
| 03_ES_Det01 |
| 04_ES_Det02 |
| 05_ES_Det03 |
| 06_ES_Det04 |
| 07_ES_Plan |
File details come from the government source that posted it. Updated .