This document is a Technical Specification for two 591 MHz, 200 kW RF amplifier systems and two 591 MHz, 400 kW RF amplifier systems to be used at the Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL), which is managed by Brookhaven Science Associates (BSA). The RF amplifier systems must be constructed with solid state devices and operate in both CW and pulsed modes, with CW being the primary mode. The 200 kW systems must be expandable to 400 kW using a waveguide combiner, and a single common controller will be used for both power levels. The specification details the technical requirements for the RF amplifier systems, including performance characteristics, stability, protections, cooling, interfaces, and remote control/monitoring capabilities. The systems must comply with relevant electrical and EMC standards. This Technical Specification supports a Pre-Solicitation for the EIC 591 MHz RF Amplifiers Systems contract opportunity from the Department of Energy Office of Science.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Electron-Ion Collider, Brookhaven National Laboratory

Doc No. EIC-RFS-SPC-006 Author: M. Sowinski Effective Date: May 30, 2024 Review Frequency: N/A

Specification Title: 591 MHz RF Amplifier Systems Revision: 03

TECHNICAL SPECIFICATION

for the

591 MHz RF Amplifier Systems Quality Classification: A-3

Prepared By:

_________________________________ Date: __________________ M. Sowinski, High Power RF Engineer

Reviewed By:

D. Lukach, Staff Electrical Engineer

F. Severino, RF Engineer

J. Zipper, Quality Assurance

C. Schaefer, ESH

C. Galdamez, Procurement Liaison Engineer

Approved By:

A. Zaltsman, RF Group Leader

DocuSign Envelope ID: BBCB6B44-9A7E-4154-9BC1-3EE500790238

5/30/2024

5/31/2024

5/30/2024

5/30/2024

5/30/2024

5/31/2024

5/31/2024

This page intentionally left blank, to accommodate back-to-back printing.

DocuSign Envelope ID: BBCB6B44-9A7E-4154-9BC1-3EE500790238

REVISION HISTORY

Revision # Effective Date Summary of Change

00 January 12, 2023 Initial Release

01 March 14, 2023

Updated the directivity requirement, duty cycle requirement, MTBF requirements, water cooling requirements, and units for remote data monitoring. Also, nomenclature, font, punctuation, and grammar corrections.

02 May 31, 2023

Added Section 3.3 for construction requirements.

Updated input power, phase linearity, pulse width, rise time, fall time, gain, and earth connection requirements.

03 May 30, 2024 Added electrical standards to Section 2 table and Section 3.2

Table of Contents

LIST OF ACRONYMS

1 SCOPE

1.1 Background

1.2 Definitions

2 APPLICABLE DOCUMENTS

3 REQUIREMENTS

3.1 Technical/Performance Characteristics

3.1.1 RF Amplifier System Characteristics

3.1.2 Stability

3.1.3 Forward Power Degradation vs Load VSWR

3.1.4 Burn-in Testing

3.1.5 Redundant Operation

3.1.6 Power Supplies

3.1.7 RF Amplifier System Reliability (MTBF)

3.1.8 Temperature Limits

3.1.9 RF Hardware Requirements

3.1.10 Environmental Conditions

3.1.11 Water Cooling

3.1.12 Air Cooling

3.1.13 External Signals and Internal / External Connections

3.1.14 Protections

3.1.15 Status and External Interlocks

3.1.16 Switches

3.1.17 Locspelal Instrumentation

3.1.18 LED Status Indicators

3.1.19 Remote Interface

3.1.20 Remote Communication Protocol

3.1.21 Network Interface Configuration

3.1.22 Remote Control Functions

3.1.23 Remote Status Monitoring and Reporting

3.1.24 Remote Measurement Data Monitoring

3.2 Code/Standard Compliance

3.3 Construction Requirements

3.4 Environment, Safety and Health

4 VERIFICATION

4.1 Classification of inspections

LIST OF ACRONYMS

AC Alternating Current BNL Brookhaven National Laboratory BSA Brookhaven Science Associates CW Continuous Wave DC Direct Current DHCP Dynamic Host Configuration Protocol EIC Electron-Ion Collider EMC Electromagnetic Compatibility ESH Environment, Safety and Health FC Center Frequency GND Ground GPM Gallons per minute LED Light Emitting Diode MTBF Mean Time Between Failures NTP Network Time Protocol PA Power Amplifier PPK Peak Power QA Quality Assurance RF Radio Frequency TTL Transistor-Transistor Logic VAC Volts Alternating Current VSWR Voltage Standing Wave Ratio

Technical Specification for the 591 MHz RF Amplifier Systems

1 SCOPE

This specification defines the technical requirements for two (2) 591MHz, 200kW RF amplifier systems and two (2) 591MHz, 400kW RF amplifier systems to be used at the Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) managed by Brookhaven Science Associates

(BSA).

1.1 Background

The EIC Project will design, build, and install the accelerator hardware for a new electron storage ring, an electron injector, and modifications to the hadron ring required to produce an electron ion collider and infrastructure. It will include one interaction region, with an allowance for a second, and one detector. The facility is designed to meet requirements to ensure high reliability and availability for the user program.

These RF amplifiers systems will be used to test, validate, and condition the EIC 591MHz single cell Superconducting Radio Frequency (SRF) cryomodule.

1.2 Definitions

Global Protection - Protection designed to be applied at the system level.

Local Protection - Protection designed to be applied at a subassembly level which typically does not act on the entire system.

RF Amplifier System - The RF amplifier system comprises all components required to bring the RF amplifier to full operation. The use of this term within this document refers to both the 200kW and 400kW RF Amplifier Systems, unless explicitly detailed separately.

RF-PA - An RF-PA is the highest power gain stage and the last gain stage within the RF amplifier chain. It typically contains two devices in push pull or four devices in quadrature.

Soft Limit - An adjustable limit to a fault or warning condition which may be further sensitized by the end user.

2 APPLICABLE DOCUMENTS

The following specifications, standards and drawings form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents shall be that in effect on the date of the solicitation or contract. Exceptions must be approved in writing by BSA.

In the event of a conflict between the applicable documents and this specification, the Contractor shall immediately notify the BSA Contractual Representative who shall in each instance determine which document takes precedence and advise the Contractor accordingly. Failure to notify BSA of a document conflict shall not relieve the Contractor’s responsibility to ensure full compliance with all requirements.

Document Number Document Title

IEC 61000-6-2 Immunity Testing of Industrial Equipment

IEC 61000-6-4 Emission Standard for Industrial Environments

29 CFR 1910 Subpart S Occupational Safety and Health Standards 1910 Subpart S - Electrical

NFPA 70E-2021

Standard for Electrical Safety in the Workplace Articles 340, 350, 360

UL 508 Standard for Industrial Control Equipment

3 REQUIREMENTS

3.1 Technical/Performance Characteristics

All requirements shall be met across the entire bandwidth of the RF amplifier system.

3.1.1 RF Amplifier System Characteristics

The RF amplifier system shall be constructed with solid state devices. Its mode of operation shall be CW and Pulsed. CW is the primary mode of operation. RF amplifier system pulsed operation will be used during cavity conditioning. The operating class shall be AB. The 200kW RF amplifier systems shall be expandable to 400kW by use of a 2-way waveguide combiner. One common controller shall exist for both the 200kW and 400kW RF amplifier systems.

Regardless of the RF output power requirement, the RF amplifier systems shall fulfill the following specific requirements. These characteristics are shown in Table 1:

Table 1: RF Amplifier System Characteristics (Power Independent)

CW Min Nominal Max Unit Operating frequency 586 591 596 MHz

Input power (for Rated Output Power) -1.5 0 +1.5 dBm Phase Linearity (40dB Dynamic Range) 30 °

Input / Output Impedance 50 Ω Input VSWR 1.5:1 ---

Input RF Overdrive 10 dBm All Harmonics -30 dBc

Spurious and Line Harmonics -80 dBc Noise Power Output (ON state) -90 dBm/Hz

Noise Power Output (STANDBY state) -154 dBm/Hz Group Delay 150 200 ns

AC to RF Efficiency (@ Full Rated Power) 45 55 % AC Voltage Input (3 Phase: 4 wire plus GND) 432 480 528 VAC

AC Voltage Input (for controls) 108 120 132 VAC AC Frequency 60 Hz Power Factor 0.90 0.95 ---

Forward RF Sample Coupling (Across Amplifier Bandwidth) 69.5 70.0 70.5 dB

Forward Directivity (Across Amplifier Bandwidth) 30 dB Reflected RF Sample Coupling (Across Amplifier

Bandwidth) 69.5 70.0 70.5 dB

Reflected Directivity (Across Amplifier Bandwidth) 30 dB

Max Audible Noise (@1m) 70 dB(A)

Pulsed RF Pulse Width .001 0.1 100 ms RF Duty Cycle 1.0 50.0 %

Rise Time 0.75 µs Fall Time 0.75 µs

Pulse Droop (@ max pulse width) 0.5 1.0 dB Phase Error Over Pulse (@ max pulse width) 2.5 5.0 °

Depending on the RF output power requirement, the RF amplifier systems shall fulfil the following specific requirements. These characteristics are shown in Table 2:

Table 2: RF Amplifier System Characteristics (Power Dependent)

Spec Unit 200kW 400kW

Minimal Output Power (CW/ Pulse) 200 400 kW Minimal Linear Power (CW/ Pulse) 200 400 kW Gain (over 40 dB Dynamic Range)1 83 +/- 1.5 86 +/- 1.5 dB

Minimal RF on/off ratio2 83 86 dB

(1) At no point shall the gain deviate more than 1.5dB from nominal. The transfer curve of output power versus drive power shall be a smooth curve devoid of discontinuities or abrupt changes.

(2) RF on/off ratio is defined as the difference in gain between the ON state and the STANDBY state.

To guarantee serviceability of the RF amplifier system without the need for setting up all low-level RF control loops, all RF stages of equivalent power and RF amplifier systems of equivalent power shall be pre-adjusted to have equal gain, RF phase, and group delay. These characteristics are shown in Table 3:

Table 3: RF Amplifier System Characteristics (System to System)

Spec Unit Gain @ Fc +/- 0.25 dB Phase @ Fc +/- 7.5 °

Group delay @ Fc +/- 1.0 ns

3.1.2 Stability

The RF amplifier system shall be unconditionally stable over the entire load space and dynamic range.

3.1.3 Forward Power Degradation vs Load VSWR

• 1:1 Load VSWR – 100% forward power

• 2:1 Load VSWR – 100% forward power

• 3:1 Load VSWR – 100% forward power

• >3:1 Load VSWR – 0% forward power

The RF amplifier system shall not be damaged in the event of a short or open circuit on the RF output.

3.1.4 Burn-in Testing

The RF amplifier system shall go through a 48-hour Burn-in Test at full rated power at the Contractor’s site, without any faults, warnings, trips, or failures.

3.1.5 Redundant Operation

Reporting of a failed/inhibited RF device will be required. A failed/inhibited RF device shall not inhibit the entire RF amplifier system. The output power shall not fold back, only natural degradation shall occur. The associated performance degradation will be expected based on the combining typology employed. Output power degradation vs number of RF-PA devices failed/inhibited shall be defined. The RF amplifier system should remain fully operational with up to 10% of all RF-PA devices failed/inhibited.

3.1.6 Power Supplies

The Contractor can select power supplies so long as the RF amplifier system characteristics comply with the requirements as specified herein. Redundancy shall exist. A single failure shall not inhibit the entire RF amplifier system and should, at minimum, be consistent with the outlined RF-PA redundancy. It is of the utmost importance to have a design which is reliable, requires minimal maintenance, and enables easy replacement of faulty modules / components. The controls shall operate on BSA supplied 120VAC. The main power supplies shall operate on BSA supplied 480VAC 3-Phase. The 480VAC 3-Phase will be 4 wire plus GND. The RF amplifier system shall be protected against damage if the AC voltage is out of range.

3.1.7 RF Amplifier System Reliability (MTBF)

The RF amplifier system shall have a predicted MTBF of greater than 10,000 hours in a sheltered 30°C environment. The RF devices shall have a predicted MTBF of greater than 35,000 hours.

3.1.8 Temperature Limits

Temperature Limits on Exposed Surfaces The temperature on any touchable surface shall be less than 48.89°C (120°F). A touchable surface is defined as any surface that can be accessed without the use of tools.

RF Device Die Temperatures The maximum die temperature of the RF devices shall not exceed 130°C over the entire load space, dynamic range, and range of environmental conditions.

3.1.9 RF Hardware Requirements

RF Switch There shall be a high-speed RF switch at the input of the RF amplifier system that shall shunt the input RF to a 50Ω termination when the RF amplifier system is in the OFF State or STANDBY State. The purpose of this switch is to quickly terminate the input RF in the event of a fault condition. The switching time of the switch shall be 100ns maximum.

Input Overdrive Protection There shall be hardware within the RF amplifier system for input overdrive protection. The hardware shall limit the RF power at the input of the system and the RF amplifier system shall not be inhibited.

Thermal Protection Thermal protection shall be fitted to heat-generating devices in the RF amplifier system to provide protection if internal temperatures exceed allowable limits.

3.1.10 Environmental Conditions

The RF amplifier system shall meet all requirements within this specification under the following conditions:

Ambient Air Temperature Ambient Air Temperature in the range of 18-30°C.

Humidity 60 % RH maximum, with range of + 5 %, non-condensing.

Elevation The elevation of the RF amplifier system will be 0-45 meters.

3.1.11 Water Cooling

Water cooling will be provided by BSA. The RF amplifier system shall incorporate water cooling to ensure that the components within the RF amplifier system stay within their thermal limits. A minimum of 80% of the heat generated by the RF amplifier system shall be removed by water cooling. The water shall exit through a flow meter for each water-cooled rack (see §3.1.17.1).

There shall be a drain valve at the bottom of each rack to drain the water. The cooling system shall be designed such that very little water remains trapped after draining. The cooling system shall be pressure tested to 200 Psi. The maximum water side drop shall be 40 Psi. Required flow rates (max, min, nom) shall be defined by the Contractor.

The water-cooling system for the RF power amplifier shall be designed to operate with the following:

• Deionized water with a resistivity of 1-2MΩ·cm

• Water inlet temperature: 30-40 °C

• Water input pressure: 80-100 PSI (nom), 150 PSI (max)

3.1.12 Air Cooling

In addition to water cooling, the RF amplifier system may incorporate air cooling to dissipate heat from other components. If required, air shall be drawn in through vents at the front of the chassis and expelled at the rear of the chassis. Redundancy shall exist. A single failure shall not inhibit the entire RF amplifier system. Air filters shall be fitted to any required fans. Fans and air filters shall be affixed in such a way that they can be easily replaced without the need to remove chassis from the racks.

3.1.13 External Signals and Internal / External Connections

3.1.13.1 RF Connectors and Waveguide

RF Input Connector The RF input connector shall be N type female.

RF Forward and Reflected Sample Connectors The RF sample connectors shall be N type female.

RF Output The RF output shall be WR1500 and located on top of the rack.

3.1.13.2 Earth Connections

Chassis Earth Connections A threaded ¼”-20 earth bolt shall be provided on the rear of each chassis within the racks.

Each chassis shall have its own earth ground cable connected to the rack.

Rack Earth Connections A threaded ¼”-20 earth bolt shall be provided on the top of each rack.

3.1.13.3 Mains Power Connections

The 120VAC inlet shall be via an IEC 3-pin inlet.

The 480VAC shall enter the rack(s) and attach to a suitable terminal block.

3.1.13.4 Remote Interface Connection

The remote interface connector shall be a RJ-45 connector.

3.1.13.5 Interlock Connections

The interlock connectors shall be located inside of the rack. The connector type shall be a 2- Pin Phoenix Contact, Male, Feed-through Header, Type DFK-MSTB.

3.1.13.6 Status Connections

The four status connectors shall be located inside of the rack. The connector type shall be a 2- Pin Phoenix Contact, Male, Feed-through Header, Type DFK-MSTB.

3.1.13.7 ON/OFF Status Connections

The four ON/OFF Status connectors shall be chassis isolated BNC type female.

3.1.13.8 Water Connections

The water inlets and outlets for each water-cooled rack shall be NPT threads.

3.1.14 Protections

The RF amplifier system shall have the following protection features:

3.1.14.1 Local Protection

Table 4: Local Protection

Warning Report through

Remote Interface

Report to Local

Interface System Action Reset

Required

RF Device Over Current Warning The current being drawn by a RF device is excessive

Y Y Remain in ON state, inhibit RF device, report location

N

RF Device Failure Warning A RF device is blown or damaged Y Y

Remain in ON state, inhibit RF device, report location

N

Thermal Warning The temperature is excessive Y Y Remain in ON state, report location N

VSWR Warning The VSWR is excessive Y Y Remain in ON state, report location N

Maximum RF Forward Power Warning The forward power is excessive

Y Y Remain in ON state, report location N

Air Flow Warning Fan failure or low flow rate Y Y Remain in ON state, report location N

Water Flow Warning The water flow rate is too low Y Y Remain in ON state, report location N

DC Power Supply Warning1

A DC power supply voltage is out of range

Y Y Remain in ON state, report location N

1) A DC power supply is defined as: any one power supply delivering power to the drain of

RF Devices.

3.1.14.2 Global Protection

Table 5: Global Protection

Warning/Fault Report through

Remote Interface

Report to Local Interface

System Action Reset Required

Input Overdrive Warning The RF input power is excessive Y Y Remain in ON state, limit input RF power N

System VSWR Fault The VSWR at output of the RF amplifier system is excessive

Y Y Go to STANDBY state Y

System Maximum RF Forward Power Fault The RF Forward power at the output of the RF amplifier system is excessive

Y Y Go to STANDBY state Y

Global Thermal Fault1

The temperature is excessive Y Y Go to STANDBY state, report location Y

Water Flow Fault The water flow rate is too low Y Y Go to STANDBY state, report location Y

AC Power Fault The 480 VAC voltage is out of range Y Y Go to OFF state Y

Auxiliary DC Power Supply Fault Auxiliary DC power supply voltage is out of range

Y Y Go to OFF state Y

RF Device Redundancy Fault2 Y Y Go to STANDBY state Y Systematic System Failure Fault3

Main system controller has identified a sequence of faults that have the potential to cause excessive damage

Y Y Go to OFF state Y

Summary Fault4 Y Y --- --- Summary Warning5 Y Y --- ---

(1) A critical temperature has been exceeded and/or component(s) temperature exceeded which can result in the consequential failure of other components.

(2) The RF Device Redundancy Fault shall trip when the sum of the following exceeds the maximum limit (see §3.1.5).

a. Number of RF Device Failure Warnings

b. Number of RF Device Over Current Warnings

c. Any other warning which results in a RF Device being inhibited.

(3) The Systematic System Fault is intended to identify cascading failures and halt operation to avoid further hardware damage. Some examples include:

a. Number of failed RF devices per unit time

b. Number of failed power supplies per unit time

c. Critical health status communications timeout

(4) A Summary Fault shall be reported when any fault occurs.

(5) A Summary Warning shall be reported when any warning occurs.

3.1.15 Status and External Interlocks

3.1.15.1 Status

The RF amplifier system shall report its current state by means of status indicators.

Status Contacts The RF amplifier system shall contain four floating relay contacts which are:

• Closed when the RF amplifier system is in the ON state;

• Open when the RF amplifier system is in the STANDBY state or OFF state;

• The contacts shall be rated to switch 1A, at up to 24V DC;

• The contacts for each floating relay shall be accessible via four Phoenix Contacts (see

§3.1.13.6).

ON/OFF Status Four ON/OFF Status outputs shall be implemented with galvanically isolated optocouplers capable of handling 30V dc (min) in the high impedance state and VCEsat shall be less than 1.0V dc for IC = 1.0mA. These indicators shall be present on four chassis isolated BNC connectors (see §3.1.13.7).

Logic for outputs 1 & 2 shall be:

• Open collector (high impedance) when the RF amplifier system is in the ON state;

• Closed channel (low impedance) when the RF amplifier system is in the OFF state or

STANDBY state

Logic for outputs 3 & 4 shall be:

• Closed channel (low impedance) when the RF amplifier system is in the ON state;

• Open collector (high impedance) when the RF amplifier system is in the OFF state or

STANDBY state

3.1.15.2 External Interlocks

The RF amplifier system shall be equipped with five external interlock connections (see §3.1.13.5). The connections shall be shorted with jumpers. These jumpers will be removed after installation.

If an interlock is opened, the RF amplifier system shall report through the remote interface and local interface, whichever interlock is open. The interlocks shall be called: Interlock A, B, C, D, & E. If Interlock A – C is opened the RF amplifier system shall go to the STANDBY state.

If interlock D or E is opened the RF amplifier system shall go to the OFF state.

3.1.16 Switches

3.1.16.1 Local / Remote Switch

The LOCAL/REMOTE switch shall be located on the front of the rack.

When the switch is in the LOCAL position, the local pushbutton controls (OFF, STANDBY/RESET, ON) shall be used to control the RF amplifier system. In this state, the RF amplifier system cannot be activated via the remote interface. When the switch is in the LOCAL position, the remote interface shall only be able to shut down the RF amplifier system.

When the switch is in the REMOTE position, the remote interface shall be used to control the RF amplifier system. In this state, the RF amplifier system cannot be activated via the local pushbutton controls. When the switch is in the REMOTE position, the pushbutton controls shall only be able to shut down the RF amplifier system.

Switching between LOCAL and REMOTE shall not change the RF amplifier system’s state.

3.1.16.2 OFF, STANDBY / RESET, and ON Switches (Local Interface)

The OFF, STANDBY/RESET and ON switches are located on the front of the rack. The use of the switches is described by the following state diagram:

Figure 1: Local Control State Diagram

The state changes shown in black shall be made only when the LOCAL/REMOTE switch is in the LOCAL position. Enabling the RF amplifier system with the switches shall not be possible in REMOTE mode. The state changes shown in red shall be made at any time regardless of the position of the LOCAL/REMOTE switch.

From the OFF state, the RF amplifier system shall be activated on by pressing the STANDBY/RESET switch followed by the ON switch. It shall not be possible to go directly from OFF to ON.

The RF amplifier system’s default state shall be OFF. In the OFF state the DC power supplies shall be off, and the RF transistors gates inhibited. When STANDBY/RESET is pressed, the DC power supplies shall turn on and RF transistor drain voltages applied. This button also resets any fault conditions that may be latched in the RF amplifier system. When ON is pressed the RF Transistor gates shall be activated, bringing the RF amplifier system into a completely enabled and ready state.

The system can be returned to the OFF state in a single step by pressing the OFF button, or in two steps by pressing STANDBY/RESET followed by OFF.

The current state of the control shall be indicated by a LED illuminator under each pushbutton.

The illuminators shall always indicate the current state of the RF amplifier system, even if it is being controlled remotely. The LED illuminators shall be visible at all angles up to 60° from orthogonal in all directions.

3.1.16.3 CRASH OFF Switch

A CRASH OFF switch shall be located on the front of the rack. The CRASH OFF switch shall be a momentary switch, with a large red button. The switch shall be able to be mechanically latched. Pressing this switch shall instantly inhibit the RF amplifier system by bringing it to the OFF state. The CRASH OFF switch shall always be functional, regardless of whether the RF amplifier system is in LOCAL or REMOTE mode.

3.1.17 Local Instrumentation

3.1.17.1 Flow Meters

A flow meter shall be present within each water-cooled rack and shall provide a low-flow interlock which inhibits the RF amplifier system if the flow is less than the threshold set on the meter itself or if there is no power to the flow meter. This connection shall be failsafe. If it is not connected, the RF amplifier system will not operate. The low-flow threshold shall be factory set. The flow meter shall have a flow rate display. The flow rates shall be available through the remote interface (see §3.1.19).

3.1.17.2 Runtime Hour Meter

There shall be a runtime hour meter to monitor the accumulating run time operating hours. The meter shall record all time while the RF amplifier system is in the ON state. It shall be non-resettable. The range shall be 0 – 99,999 hours (minimal). The display shall be located on the front of the rack.

3.1.17.3 Digital RF Power Meter

There shall be a digital power meter to monitor the forward and reflected power of the RF amplifier system. The accuracy shall be +/- 2.0% into 50 Ω, over the entire dynamic range.

Power shall be displayed in kilowatts. The display shall be located on the front of the rack.

Power monitoring shall also be available through the remote interface (see §3.1.19).

3.1.18 LED Status Indicators

The status of the RF amplifier system shall be indicated locally by a LED array on the front of each rack. The LEDs shall indicate important aspects of the operating status, fault/warning status and control signal status. In general, a simple color code shall apply, whereby a white LED indicates a fault/warning condition, and a green LED indicates a normal condition.

The LEDs under the local push button switches shall be:

• OFF: green

• STANDBY/RESET: orange

• ON: red

3.1.19 Remote Interface

3.1.19.1 Ethernet Based Control

Remote control of the RF amplifier system shall be available via ethernet interface from BSAs control system. It shall be capable of controlling the RF amplifier system functions while in REMOTE mode.

3.1.19.2 Remote Monitoring Capabilities

Remote interface shall provide remote access to full status reporting including the RF amplifier system’s state, measurement data, and interlock conditions while in ether LOCAL or REMOTE mode.

3.1.19.3 Data Time Stamping

All data shall be made available for remote monitoring with time stamp that has 1 ms of accuracy.

3.1.19.4 Controller Power Source

The RF amplifier system’s control interface will be powered by a separate 120V AC power source independent of the main 480V AC.

3.1.20 Remote Communication Protocol

The RF amplifier system shall interface to BSA’s control system via an ethernet copper cable (1000BASE-T) using one or more of the following communication protocols to allow integration with BSA’s control system:

• Modbus/TCP

• Ethernet/IP

• OPC-UA.

3.1.21 Network Interface Configuration

3.1.21.1 Ethernet Configuration

Both Dynamic Host Configuration Protocol (DHCP) and STATIC Ethernet configurations shall be supported.

3.1.21.2 MAC Address

The network interface’s MAC address shall be displayed or printed on the control panel.

3.1.21.3 IP Address

The configured IP addresses shall be displayable on the control panel on a digital display.

3.1.22 Remote Control Functions

3.1.22.1 RF Amplifier System States

The OFF, STANDBY/RESET and ON states shall be settable via remote interface when RF amplifier system is in REMOTE mode. Switching states shall produce the same action while in LOCAL or REMOTE mode (see §3.1.16.1, §3.1.16.2).

3.1.22.2 Controller’s Remote Configuration

The RF amplifier system’s controller shall be capable of remotely rebooting via an ethernet software request. The controller’s firmware shall be upgradable over ethernet.

3.1.22.3 Time Stamp Synchronization

The controller shall synchronize its time-of-day clock over ethernet using an NTP server.

3.1.22.4 Control of RF Amplifier System Soft Limits

Any RF amplifier system soft limits shall be settable/changeable using the remote interface.

3.1.23 Remote Status Monitoring and Reporting

All status data shall be accessible through the remote interface and shall include:

• RF amplifier system current state (OFF, STANDBY/RESET and ON)

• RF amplifier system LOCAL/REMOTE switch state (LOCAL, REMOTE)

• RF amplifier system CRASH OFF switch state (Okay, CRASH)

• External interlocks states (see §3.1.15.2)

• All fault and warning status shall be accessible through the remote interface (see §3.1.19

§3.1.20). The status shall include the fault/warning physical location(s).

• RF amplifier system first fault condition (reports original/first cause of RF amplifier system fault)

• Controller shall capture and store at least 1000 entries of each of the following status in a nonvolatile circular buffer. All entries shall include time stamp with at least 1 ms of time accuracy. Any number of entries shall be read on request via remote interface:

o RF amplifier system first fault history (first cause for RF amplifier system fault condition) o RF amplifier system fault history capturing any fault, warning, internal & external interlocks.

o RF amplifier system state history which includes cause/reason for the change between states. It shall clearly indicate the action that caused the RF amplifier system to switch between states (front panel command, remote command, or fault condition)

3.1.24 Remote Measurement Data Monitoring

Table 6: Remote Data Monitoring

Name Description Units

Input drive power Power @ input before attenuation/amplification mW

RF amplifier system forward RF power Power at system output kW RF amplifier system reflected RF power Power at system output kW Rack forward RF powers Power at output of each rack kW Rack reflected RF powers Power at output of each rack kW

Other forward RF powers Anywhere else RF power is being monitored W

Other reflected RF powers Anywhere else RF power is being monitored W

RF Transistor Currents DC current for each RF transistor A Water Flow rates Flow rate at each rack GPM

Percent of active RF-PA transistors Percent of RF-PA transistors that are operational (not failed/inhibited) %

Number of active RF-PA transistors Number of RF-PA transistors that are operational (not failed/inhibited) ---

Temperatures Anywhere temperature is being measured °C DC Voltages Anywhere DC voltage is being measured V

Other DC currents Anywhere else DC Current is being measured A

3.2 Code/Standard Compliance

• Electromagnetic Compatibility

The 200kW and 400kW RF amplifier systems should be designed to be compatible with the following EMC regulations in force, and should neither be perturbed nor perturb other installations according to these regulations:

• EMC Immunity: IEC 61000-6-2;

• EMC Emissions: IEC 61000-6-4.

It shall be assumed that throughout this specification, unless explicitly detailed separately for a given parameter, each RF amplifier system is treated as Class A, Group 1 equipment. The corresponding conducted and radiated limits should be understood, and design practices applied accordingly.

• Electrical Code

The 200kW and 400kW RF amplifier systems shall be designed following the below electrical codes:

• 29 CFR 1910 Subpart S - Electrical

• NFPA 70E-2021

o Article 340 (Power Electronic Equipment), o Article 350 (Safety Requirements for R&D Labs) o Article 360 (Safety Requirements for Capacitors)

• UL 508

With the exception of UL 508, all other referenced standards are required to be implemented.

3.3 Construction Requirements

The racks shall be constructed to allow for the use of a pallet jack or forklift which will be used to move the racks into their final locations.

3.4 Environment, Safety and Health

Identification of hazards, and their mitigation, during all stages of the life of the Equipment including; installation, commissioning, operation, maintenance, and repair. Identification of means to eliminate or manage each hazard shall be provided based on the following hierarchy:

• Eliminate the hazard, or manage the hazards in the following hierarchy;

• Substitute with something less hazardous,

• Engineer – mitigate the severity of the hazard,

• Administrative controls (e.g. training, procedures) or

• Use Personal Protective Equipment (least desirable).

4 VERIFICATION

Appropriate inspection/tests shall be performed to ensure Equipment conforms to all requirements in section 3 of this specification.

4.1 Classification of inspections

Items covered by this specification shall be subjected to the following tests to determine compliance with all applicable requirements:

4.1.1. Acceptance Tests

• Contractor Acceptance Test

• Factory Acceptance Test at Contractor site

• BSA Site Acceptance Test

LIST OF ACRONYMS
1 SCOPE
1.1 Background
1.2 Definitions
2 APPLICABLE DOCUMENTS
3 REQUIREMENTS
3.1 Technical/Performance Characteristics
3.1.1 RF Amplifier System Characteristics
3.1.2 Stability
3.1.3 Forward Power Degradation vs Load VSWR
3.1.4 Burn-in Testing
3.1.5 Redundant Operation
3.1.6 Power Supplies
3.1.7 RF Amplifier System Reliability (MTBF)
3.1.8 Temperature Limits
3.1.9 RF Hardware Requirements
3.1.10 Environmental Conditions
3.1.11 Water Cooling
3.1.12 Air Cooling
3.1.13 External Signals and Internal / External Connections
3.1.13.1 RF Connectors and Waveguide
3.1.13.2 Earth Connections
3.1.13.3 Mains Power Connections
3.1.13.4 Remote Interface Connection
3.1.14 Protections
3.1.14.1 Local Protection
3.1.14.2 Global Protection
3.1.15 Status and External Interlocks
3.1.15.1 Status
3.1.15.2 External Interlocks
3.1.16 Switches
3.1.16.1 Local / Remote Switch
3.1.16.2 OFF, STANDBY / RESET, and ON Switches (Local Interface)
3.1.16.3 CRASH OFF Switch
3.1.17 Local Instrumentation
3.1.17.1 Flow Meters
3.1.17.2 Runtime Hour Meter
3.1.17.3 Digital RF Power Meter
3.1.18 LED Status Indicators
3.1.19 Remote Interface
3.1.19.1 Ethernet Based Control
3.1.19.2 Remote Monitoring Capabilities
3.1.19.3 Data Time Stamping
3.1.20 Remote Communication Protocol
3.1.21 Network Interface Configuration
3.1.21.1 Ethernet Configuration
3.1.21.2 MAC Address
3.1.22 Remote Control Functions
3.1.22.1 RF Amplifier System States
3.1.22.2 Controller’s Remote Configuration
3.1.22.3 Time Stamp Synchronization
3.1.22.4 Control of RF Amplifier System Soft Limits
3.1.23 Remote Status Monitoring and Reporting
3.1.24 Remote Measurement Data Monitoring
3.2 Code/Standard Compliance
3.3 Construction Requirements
3.4 Environment, Safety and Health