5-ATTACHMENT 5-15-11 Plans and Elevations.pdf
PDF 10 MB Posted
- Solicitation number
- IFB-0651-DCH (DEMOLITION AND RENOVATION OF ONE (1) DUPLEX UNIT WITH TWO (2) APARTMENTS
- Issued by
- Arizona
About this file
This is an architectural plans and elevations document for a demolition and renovation project involving one duplex unit with two apartments located within the Gila River Indian Community in Arizona. The project scope includes construction of new 2x4 frame walls with 2x furring for insulation and T1-11 vertical siding at the exterior of both units. The plans specify installation of new washer outlets and drain boxes recessed in the frame walls, coordinated with existing drain lines, as well as removal and relocation of existing ABS drain lines. Additionally, both apartments are to receive new heat pump AC units complete with all new flex duct, registers, cans, air return systems, and associated HVAC components. The document establishes fire wall separation requirements between the two units and provides reference plans for the proposed work.
The file contains technical architectural drawings and specifications necessary for bidders to understand the renovation requirements. No specific pricing terms, set-asides, contract duration, award dates, or response deadlines are outlined in this attachment. The plans serve as design guidance and technical reference material for contractors submitting bids on the demolition and renovation opportunity.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT 5
ajone Rectangle ajone Line ajone Rectangle ajone Line ajone Ellipse ajone Rectangle ajone Rectangle ajone Cloud+ ajone Cloud+ 2x4 FRAME WALL WITH 2X FURRING FOR INSULATION AT INTERIOR AND T1-11 VERTICAL SIDING AT EXTERIOR, TYP. BOTH UNITS ajone Cloud+ ajone Cloud+ PROVIDE NEW WASHER OUTLET/ DRAIN BOX RECESSED IN FRAME WALL, COORDINATE WITH EXISTING DRAIN LINE, TYP. BOTH UNITS ajone Cloud+ ajone Cloud+
REMOVE ABS DRAIN AND COORDINATE AT NEW LOCATION IN FRAME WALL
ajone Cloud+ ajone Cloud+
T1-11 SIDING THIS LOCATION
ajone Line ajone Text Box
01 - FIRE WALL SEPARATION
ajone Cloud ajone Text Box ajone Ellipse ajone Cloud ajone Arrow
Both Apartments (units) to receive new heat pump AC units and all new flex duct, registers cans, air return and other associated items. Plans below shown for reference.