5-1. 10 31 2025 - Boulder County Community Hub - CD AND BID PACKAGE - ELECTRICAL - Combined.pdf
PDF 9 MB Posted
- Attached to
- Boulder Hub Lighting and Lighting Controls
- Solicitation number
- BID-244-26
- Issued by
- Boulder County, Colorado
About this file
Boulder County Community Hub Electrical and Lighting Project Summary
This electrical bid package and contract opportunity involves Boulder County, Colorado, for comprehensive electrical work including power distribution, lighting fixtures, and lighting control systems for the Boulder County Community Hub, a 40,000-square-foot renovation project located at 2528th Street, Boulder, Colorado 80301. The project encompasses demolition and installation of electrical systems across three levels (lower level parking garage, Level 1, and Level 2) and roof areas. The scope includes replacement of the main distribution panelboard (1,600-ampere service), transformers, branch circuit panelboards, lighting fixtures, emergency lighting systems, fire alarm systems, mechanical equipment connections, and a complete lighting control infrastructure featuring networked, room-based, and standalone controls with occupancy sensors and daylight harvesting capabilities. The project requires coordination with a utility company for transformer installation and upgrade, integration of a 50-kilowatt natural gas standby generator with automatic transfer switch, and photovoltaic system integration. The bid package includes detailed specifications, one-line diagrams, panel schedules, lighting fixture schedules, and lighting control zone schedules. The contract is for material supply only, with Boulder County's in-house electrical team providing labor.
The lighting and lighting controls portion is offered as a separate bid opportunity for material supply, excluding labor costs. Key specifications include LED lighting fixtures across multiple types (linear, troffer, pendant, downlight, sconce, and exterior fixtures) with 0-10V dimming capability and color temperature of 3,500K, along with emergency lighting backup systems providing 90 minutes of battery backup. Lighting control systems must comply with 2021 IECC Section C405 requirements for occupancy sensors, automated scheduling, and daylight harvesting in specified zones. The project mandates compliance with the 2023 National Electrical Code (NEC), 2021 International Building Code (IBC), 2024 City of Boulder Energy Conservation Code, and local authority requirements. Contractors must submit shop drawings, provide commissioning documentation including cutsheets and operation manuals, conduct functional testing of lighting controls, and provide two hours of owner training with video documentation. The electrical contractor is responsible for all permits, governmental fees, and coordination with mechanical, plumbing, and other trade contractors, with particular attention to fire-rated penetrations, existing equipment demolition, and circuit continuity for retained systems.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. WHERE MULTIPLE LINE VOLTAGE DEVICES ARE SHOWN ADJACENT TO EACH OTHER, THEY ARE ALL TO SHARE THE SAME
JUNCTION BOX, UP TO FOUR GANGS.
2. WHERE MORE THAN FOUR DEVICES ARE SHOWN ADJACENT TO EACH OTHER, DEVICES ARE TO STACK VERTICALLY ABOVE ONE ANOTHER IN TWO ROWS IN AS SMALL OF GANG BOXES AS POSSIBLE. I.E. SIX DEVICES WILL USE TWO THREE GANG BOXES, FIVE DEVICES WILL USE ONE THREE GANG AND ONE TWO GANG BOX. WHEN DIMMERS ARE GANGED TOGETHER, REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR DE-RATING.
3. BACK-TO-BACK JUNCTION BOXES IN COMMON WALLS ARE NOT PERMITTED. JUNCTION BOXES SHALL BE SEPARATED BY AT
LEAST ONE STUD WHEREVER POSSIBLE.
4. AUDIBLE/VISUAL FIRE ALARM DEVICES SHOWN ARE TO BE MOUNTED AT 90" OR 6" BELOW CEILING, WHICHEVER IS LOWER.
ADA STROBES TO BE MOUNTED AT 80" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER.
5. MAXIMUM ELEVATION FOR ALL LOAD CENTER CIRCUIT BREAKERS SHALL NOT EXCEED 48" AFF, WITHIN DWELLING UNITS.
6. THE E.C. SHALL REFER TO ARCHITECTURAL ELEVATIONS TO COORDINATE ALL COUNTER HEIGHTS. ALL "AC" DEVICES SHALL
HAVE BOTTOM OF BACK-BOX MOUNTED 4" ABOVE THE BACK/SIDE SPLASH.
NOTES:
FAA
S
6'-8"
5'-4"
6'-0"
TO CENTER
(SEE NOTE 6)
1'-6"
3'-8"
TO BOTTOM OF DEVICE (SEE NOTE 4)
TOP OF CABINET
CENTER OF CABINET
TYPICAL 9'-0" CEILING
TYPICAL 8'-0" CEILING
8'-0"
7'-4"
TO CENTER
TO BOTTOM
5'-0"
TO CENTER
AC AC AC AC
POWER PANEL, FIRE
ALARM PANEL, OR
MASTER CLOCK
V/TP/KP/$X
I/O
A
A
MDC
TC
HP
R
J
M
T
SYSTEMS
DISTRIBUTION AND RACEWAY LIGHTING FIXTURES
WIRING DEVICES
SYMBOLS
J
J
SR
x x x x x x x POOL EQUIPMENT SCHEDULE NOTATION
KITCHEN EQUIPMENT SCHEDULE NOTATION
MECHANICAL EQUIPMENT SCHEDULE NOTATION
DETAIL NOTE
DELTA REVISION NOTE
ELECTRICAL WIRE SIZE
MAIN DISTRIBUTION CENTER (MDC)
SURFACE MTD PANELBOARD
RECESSED PANELBOARD
TRANSFORMER
BRANCH CIRCUIT HOMERUN
CONDUIT CONCEALED IN FLOOR OR UNDERGROUND
CONDUIT EXPOSED OR CONCEALED IN WALL OR
CEILING
RACEWAY UP
RACEWAY DOWN
CAPPED CONDUIT
CURRENT TRANSFORMER
CIRCUIT BREAKER SWITCH
FUSED SWITCH
GROUNDING ELECTRODE CONDUCTOR
METER
TTB, MDF OR IDF SYSTEM BACKBOARD
TELECOMMUNICATION OUTLET
FLOOR MOUNTED TELECOMMUNICATION OUTLET
TELEVISION OUTLET
CABLE TRAY (LENGTH AS INDICATED ON DRAWINGS)
LUMINAIRE TYPE, REFERENCING LUMINAIRE SCHEDULE,
TYPICAL ALL FIXTURES. SUBSCRIPT, IF SHOWN,
REFERENCES WALL SWITCH OR RELAY/ZONE CONTROL
WALL MOUNTED LUMINAIRE
SURFACE OR PENDANT MOUNTED LUMINAIRE
RECESSED LUMINAIRE
RECESSED DOWNLIGHT LUMINAIRE
SURFACE CEILING LUMINAIRE
PENDANT LUMINAIRE
ARROW INDICATES DIRECTIONAL LUMINAIRE
SURFACE OR PENDANT TRACK LUMINAIRE
REFER TO FIXTURE SCHEDULE FOR HEAD QTY.
EXIT LUMINAIRE - SHADED INDICATES FACE /
DIRECTIONAL ARROWS AS SHOWN
BATTERY PACK EMERGENCY LUMINAIRE
HATCH INDICATES EMERGENCY LUMINAIRE
PORCELAIN KEYLESS LAMP HOLDER
STEP LIGHT TYPE LUMINAIRE
BOLLARD LUMINAIRE
EXTERIOR AREA LIGHT
DUPLEX RECEPTACLE
FOUR PLEX RECEPTACLE
SINGLE RECEPTACLE
COMBO RECEPTACLE/SWITCH
SWITCHED DUPLEX RECEPTACLE
SPECIAL PURPOSE RECEPTACLE
FLOOR MOUNTED SPECIAL PURPOSE RECEPTACLE
FLOOR MOUNTED RECEPTACLE DUPLEX/QUAD
SURFACE RACEWAY
CLOCK RECEPTACLE
JUNCTION BOX
WALL MOUNTED J-BOX
FLOOR MOUNTED JUNCTION BOX
MOLDED CASE CIRCUIT BREAKER IN ENCLOSURE
NON-FUSED DISCONNECT SWITCH
FUSED DISCONNECT SWITCH
MAGNETIC CONTROLLER (STARTER)
COMBINATION STARTER/DISCONNECT SWITCH
MOTOR
RELAY
TIME CLOCK
THERMAL OVERLOAD SWITCH
SINGLE POLE SWITCH, LINE VOLTAGE
3-WAY SWITCH, LINE VOLTAGE
4-WAY SWITCH, LINE VOLTAGE
KEY OPERATED SWITCH
DIMMER SWITCH, LINE VOLTAGE
RECESSED DOOR SWITCH
LIGHTING CONTROL DEVICE, REFER TO DETAILS FOR
CONTROL INTENT
EMERGENCY POWERED DUPLEX RECEPTACLE
CEILING MOUNTED RECEPTACLE DUPLEX/QUAD
CLGCLG
GFP GROUND FAULT PROTECTION
A1 a
FLOOR OR TABLE LAMP
LED TAPE LUMINAIRE
K
MONOPOINT LUMINAIRE
RECESSED MULTI-HEAD LUMINAIRE
IN-GRADE UPLIGHT
FESTOON LIGHTING
T1 LIGHTING CONTROLS SEQUENCE OF OPERATION
DOOR
TO
D
K
X
PEDESTRIAN POLE OR POST TOP LUMINAIRE
SWITCHED FOUR PLEX RECEPTACLE
CR CARD READER, ROUGH-IN
NTSE-000
DEVICE MOUNTING HEIGHT1
ELECTRICAL GENERAL NOTES
1. THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A COMPLETE AND
FUNCTIONING ELECTRICAL SYSTEM.
2. MATERIALS AND INSTALLATION SHALL COMPLY WITH CODES, LAWS AND ORDINANCES OF FEDERAL, STATE AND LOCAL GOVERNING BODIES HAVING JURISDICTION.
3. MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY U.L., ETL, CSA OR ANOTHER
RECOGNIZED TESTING LAB.
4. ALL WORK REQUIRED FOR THE INSTALLATION AS SHOWN ON DRAWINGS INCLUDING LABOR, EQUIPMENT AND MATERIALS SHALL BE IN STRICT COMPLIANCE WITH THE BUILDING STANDARDS, EXCEPT AS NOTED
OTHERWISE.
5. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, GOVERNMENTAL FEES, TAXES AND LICENSES NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE ELECTRICAL WORK.
6. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO GOVERNMENTAL AGENCIES AND UTILITY COMPANIES
SHOP DRAWINGS, WHICH ARE REQUIRED BY THESE AGENCIES, FOR THEIR APPROVAL.
7. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/OWNER OF ANY MATERIALS OR
APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN VIOLATION OF LAWS, ORDINANCES, RULES
OR REGULATIONS OF AUTHORITIES HAVING JURISDICTION.
8. FOR ALL JOBS THAT INCLUDE DEMOLITION WORK BY THE ELECTRICAL CONTRACTOR, DURING AND AFTER DEMOLITION, EC SHALL MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING DEVICES THAT ARE TO REMAIN. EC SHALL REMOVE, RELOCATE, AND/OR REWORK ANY CONDUIT AND WIRING TO FACILITATE THE NEW CONSTRUCTION SCOPE OF WORK. FOR ALL LUMINAIRES THAT ARE EXISTING TO REMAIN OR EXISTING TO BE RELOCATED, EC SHALL CLEAN LENSES AND REPLACE ALL EXTINGUISHED LAMPS, UON.
9. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, AND THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE
CONTRACT.
10. ALL MATERIALS, AND EQUIPMENT SHALL BE ERECTED, INSTALLED, CONNECTED, CLEANED, ADJUSTED, TESTED, CONDITIONED, AND PLACED IN SERVICE IN ACCORDANCE WITH THE MANUFACTURER'S
DIRECTIONS AND RECOMMENDATIONS.
11. ALL CUTTING, DRILLING AND PATCHING OF MASONRY, STEEL OR IRON WORK BELONGING TO THE BUILDING MUST BE DONE BY THIS CONTRACTOR IN ORDER THAT THEIR WORK MAY BE PROPERLY INSTALLED, BUT UNDER NO CONDITIONS MAY STRUCTURAL WORK BE CUT, EXCEPT AT THE DIRECTION
OF THE ARCHITECT-DESIGNER OR THEIR REPRESENTATIVE.
12. E.C. IS TO REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR ALL FIRE RATED PENETRATION INSTALLATION REQUIREMENTS. E.C. IS TO NOTIFY ENGINEER AND ARCHITECT PRIOR TO INSTALLING ANY FIXTURES WITHIN A FIRE RATED CEILING OR WALL. FIRE RATING MUST BE MAINTAINED FOR THIS
TYPE OF INSTALLATION WITH DRYWALL TENTING.
13. E.C. SHALL PROVIDE COORDINATION STUDY OF NEW AND/OR NEW GEAR COMBINED WITH EXISTING
GEAR DURING THE SUBMITTAL PROCESS.
14. SHOP DRAWINGS SHALL INCLUDE MANUFACTURER'S NAMES, CATALOG NUMBERS, CUTS, DIAGRAMS AND OTHER SUCH DESCRIPTIVE DATA AS MAY BE REQUIRED TO IDENTIFY AND REVIEW THE EQUIPMENT.
SUBMITTALS SHALL BE IN LOGICAL GROUPS, FOR EXAMPLE, ALL LIGHTING FIXTURES, PARTIAL
SUBMITTALS WILL NOT BE REVIEWED.
15. SUBMIT ELECTRONIC COPIES OF THE FOLLOWING SHOP DRAWINGS FOR REVIEW:
A. SWITCH BOARD, PANELBOARDS, AND METERING EQUIPMENT
B. DISCONNECTS
C. LIGHT FIXTURES
D. LIGHTING CONTROLS
E. TRANSFORMERS
F. PROVIDE "AS-BUILT" DRAWINGS AND SUBMIT TO ARCHITECT/DESIGNER.
16. PROVIDE THE FOLLOWING INFORMATION, PER COBECC 2024 C408.3.2.2. TO THE PARTY RESPONSIBLE
FOR PROJECT COMMISSIONING PLAN (COMMISSIONING AGENT/ MECHANICAL ENGINEER) AND
ELECTRICAL ENGINEER:
A. CUTSHEETS FOR ALL INSTALLED LIGHTING AND LIGHTING CONTROLS.
B. OPERATION AND MAINTENANCE MANUALS FOR EACH PIECE OF INSTALLED LIGHTING, REQUIRED
ROUTINE MAINTENANCE ACTIONS, CLEANING AND RECOMMENDED RELAMPING SHALL BE CLEARLY
IDENTIFIED.
C. SCHEDULE FOR INSPECTING AND RECALIBRATING ALL LIGHTING CONTROLS. INSPECTION OF ALL LIGHTING CONTROLS SHALL BE PERFORMED PRIOR TO ELECTRICAL ENGINEER'S COMMISSIONING SITE VISIT. RECALIBRATION OF LIGHTING CONTROLS SHALL BE PERFORMED FOLLOWING SITE VISIT
AND SHALL BE BASED UPON THE RECOMMENDATIONS OF THE ELECTRICAL ENGINEER.
17. ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW, UNLESS SPECIFICALLY INDICATED AS
EXISTING TO BE REUSED.
18. CONTRACTOR SHALL OBTAIN AND VERIFY EXACT UTILITY COMPANY DRAWINGS AND REQUIREMENTS.
ELECTRICAL CONTRACTOR IS TO SUBMIT A COMPLETE CONSTRUCTION DRAWING SET TO THE
ELECTRICAL UTILITY COMPANY WITHIN 10 DAYS OF AWARD OF CONTRACT. COORDINATE TIMELINE OF THE REVIEW, APPROVAL, ALL ASSOCIATED DOWN TIME, CONSTRUCTION SCHEDULING, DELIVERY, AND
INSTALLATION OF THE UTILITY TRANSFORMER. NOTIFY OWNER OF SCHEDULING CONFLICTS.
19. ALL NEW CIRCUIT BREAKERS FOR NEW OR EXISTING PANELBOARDS SHALL MATCH EXISTING BUILDING
PANELBOARD MANUFACTURER AND BREAKER TYPE. THE CONTRACTOR SHALL PROVIDE NEW TYPE
WRITTEN PANEL DIRECTORIES FOR ALL NEW PANELS AND EXISTING PANELS WHICH HAVE CHANGED.
PANELBOARD SHALL BE MARKED WHERE THE SOURCE OF POWER SUPPLY ORIGINATES, AND IF SERIES
COMBINATION SYSTEMS ARE UTILIZED AND THEIR LISTED AMPERE RATING.
20. DO NOT SHARE NEUTRAL CONDUCTORS FOR MULTIWIRE BRANCH CIRCUITS. WHERE SHARED NEUTRAL CONDUCTORS ARE REQUIRED (SUCH AS POWERED FURNITURE SYSTEMS), HANDLE TIES SHALL BE PROVIDED ON THE CIRCUIT BREAKERS, WITH SHARED NEUTRALS, SUCH THAT IT WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS. ALL HANDLE TIES ARE REQUIRED TO BE INDICATED ON
THE PANELBOARD SHOP DRAWINGS.
21. SHOULD ACTUAL FIELD CONDITIONS REQUIRE CIRCUIT DESIGNATIONS INDICATED ON PLANS TO VARY, ELECTRICAL CONTRACTOR SHALL PROVIDE EQUIPMENT LABELS AND CIRUIT DIRECTORIES TO MATCH INSTALLED CONDITIONS IN COMPLIANCE WITH NEC 408.4. MODIFIED CIRCUIT DESCRIPTION AND NUMBER USED SHALL BE INDICATED ON THE "AS-BUILT" DRAWINGS PROVIDED TO THE ENGINEER OF RECORD.
22. ALL SERVICE EQUIPMENT (OTHER THAN IN DWELLING UNITS) SHALL BE LEGIBLY MARKED IN THE FIELD BY THE ELECTRICAL CONTRACTOR WITH THE MAXIMUM AVAILABLE FAULT CURRENT AS INDICATED WITHIN THESE DOCUMENTS. THE FIELD MARKING(S) SHALL COMPLY WITH ELECTRICAL SPECIFICATIONS FOR
READABILITY AND DURABILITY.
23. PROVIDE COMPLETE METAL RACEWAY SYSTEMS AND ENCLOSURES FOR ALL WIRING THROUGHOUT THE
EXTENT OF THE REQUIRED DISTRIBUTION SYSTEM.
A. UTILIZE RIGID POLYVINYL CHLORIDE CONDUIT (PVC) IN THE FOLLOWING LOCATIONS:
• UNDERGROUND
B. UTILIZE ELECTRICAL METALLIC TUBING (EMT), MINIMUM SIZE OF 3/4", IN THE FOLLOWING
LOCATIONS:
• SERVICE & FEEDERS
• POWER CIRCUIT HOMERUN
• BRANCH CIRCUITS IN CONCEALED OR EXPOSED LOCATIONS
• TELEPHONE/DATA/CATV ROUGH-IN
C. UTILIZE METAL-CLAD CABLE (MC) IN THE FOLLOWING LOCATIONS:
• BRANCH CIRCUIT IN CONCEALED LOCATIONS
• FINAL CONNECTION TO RECESSED LIGHTING FIXTURES
• FINAL CONNECTION TO STEP-DOWN TRANSFORMERS
24. ALL NEW CIRCUITS SHALL HAVE A GROUND WIRE INSTALLED.
25. ALL WIRING NOT INSTALLED IN CONDUIT AND INSTALLED IN THE CEILING SPACE SHALL BE PLENUM
RATED
26. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT MAY BE REQUIRED TO
ENCLOSE RECEPTACLES.
27. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT MAY BE REQUIRED TO ENCLOSE RECEPTACLES.EACH SWITCH, LIGHT, RECEPTACLE AND OTHER MISCELLANEOUS DEVICE SHALL BE PROVIDED WITH A GALVANIZED OR PRESSED STEEL OUTLET BOX OF THE KNOCKOUT TYPE, OF NOT LESS THAN NO. 14 U.S. GAUGE STEEL. CONDUITS SHALL BE FASTENED WITH LOCKNUTS AND BUSHINGS AND ALL UNUSED KNOCKOUTS MUST BE LEFT SEALED. THERE MUST BE SUFFICIENT ROOM FOR WIRES AND BUSHINGS AND DEEP BOXES SHALL BE INSTALLED WHERE REQUIRED. BOXES SHALL BE SECURELY
AND ADEQUATELY SUPPORTED.
28. IN EXPOSED AND SUSPENDED CEILING APPLICATIONS, ROUTE CONDUIT AS CLOSE TO STRUCTURAL SLAB OR DECK AS POSSIBLE, AND SUPPORT CONDUIT AND JUNCTION BOXES DIRECTLY FROM THE STRUCTURAL SLAB, DECK, OR FRAMING PROVIDED FOR THAT PURPOSE. LIGHTING BRANCH CIRCUIT CONDUITS SHALL NOT BE CLIPPED TO THE CEILING SYSTEM UNLESS IT HAS BEEN SPECIFICALLY DESIGNED FOR THAT
PURPOSE.
29. ALL EXPOSED CONDUIT SHALL BE CONCEALED TO THE GREATEST EXTENT POSSIBLE, AND SHALL BE INSTALLED PARALLEL AND CLOSE TO STRUCTURAL MEMBERS. GENERAL CONTRACTOR SHALL PAINT
CONDUIT TO MATCH ADJACENT FINISHES.
30. WHERE FLOOR FITTINGS REQUIRE PENETRATION OF THE FLOOR SLAB, THEY SHALL BE STANDARD DEVICE LISTED BY UL FOR THE PURPOSE AND HAVE A UL FIRE RATING EQUAL TO THE FLOOR RATING. FLOOR SERVICE BOXES SHALL BE MODULAR, ADJUSTABLE FLUSH TYPE, DUAL SERVICE UNITS SUITABLE FOR
WIRING METHOD USED. COMPARTMENT BARRIERS SHALL SEPARATE POWER FROM LOW VOLTAGE
CABLING. PROVIDE RECTANGULAR SERVICE PLATE WITH SATIN FINISH.
31. ALL RECEPTACLES SHALL BE SPECIFICATION GRADE NEMA 5-20R, UNLESS OTHERWISE NOTED.
32. ALL LIGHT SWITCHES SHALL BE SPECIFICATION GRADE, QUIET OPERATION RATED 120/277 VOLT, 20
AMPS, UNLESS OTHERWISE NOTED.
33. ALL FACE PLATE AND DEVICE COLORS SHALL BE APPROVED BY ARCHITECT OR OWNER/LEASEE.
34. LUMINAIRES SHOWN AS SHADED SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP POWER.
EMERGENCY LUMINAIRES SHALL SENSE UNSWITCHED POWER TO THE SPACE AND OPERATE
AUTOMATICALLY UPON LOSS OF NORMAL POWER. ALL SHADED LUMINAIRES WITH LED SOURCES SHALL BE PROVIDED WITH 90 MINS OF BACKUP POWER VIA INTEGRAL BATTERY OR EXTERNAL MINI/MICRO INVERTERS AS SPECIFIED IN THE LUMINAIRE SCHEDULE. ALL EMERGENCY LUMINAIRES WITH INTEGRAL BATTERY, EMERGENCY LIGHTING UNITS, AND INVERTERS SHALL HAVE INTEGRAL OR REMOTE TEST SWITCHES WITH VISIBLE INDICATOR LIGHTS, AS INDICATED IN THE FIXTURE SCHEDULE. THE EMERGENCY BATTERY OR INVERTER SHALL BE CONNECTED TO THE UNSWITCHED LEG OF THE LIGHTING CIRCUIT
INDICATED TO DETECT THE LOSS OF NORMAL POWER.
35. CIRCUIT ALL EMERGENCY LIGHTING UNITS (FROG EYES) AND EXIT SIGNS TO NEAREST LOCAL AREA
LIGHTING BRANCH CIRCUIT AHEAD OF ALL SWITCHLEGS, UNLESS OTHERWISE NOTED.
36. UNLESS OTHERWISE NOTED, LUMINAIRES DESIGNATED AS NIGHT LIGHT (NL) SHALL BE CONNECTED
AHEAD OF LOCAL SWITCHING AND REMAIN ON 24 HOURS A DAY.
37. ALL DIMMED LIGHTING CIRCUITS ARE TO RECEIVE DEDICATED NEUTRALS. DO NOT SHARE NEUTRALS ON
DIMMED LIGHTING CIRCUITS.
38. PROVIDE OWNER WITH A COMPLETE LISTING OF ALL LAMPS UTILIZED ON THE PROJECT INCLUDING MANUFACTURER AND CATALOG INFORMATION. PROVIDE A SUGGESTED SOURCE, INCLUDING CONTACT
NAME AND PHONE NUMBER, FOR REORDERING.
39. THE CONTRACTOR SHALL VERIFY THE CEILING TYPE BEFORE ORDERING LIGHTING FIXTURES.
40. ROUGH-IN FOR MECHANICAL EQUIPMENT SHALL ONLY OCCUR AFTER MECHANICAL EQUIPMENT SUBMITTALS ARE THOROUGHLY REVIEWED FOR CHANGES. NOTIFY ENGINEER OF ANY DISCREPANCIES.
41. FINAL LAYOUT AND QUANTITY OF ALL FIRE ALARM DEVICES SUBJECT TO APPROVAL OF LOCAL
AUTHORITY HAVING JURISDICTION.
42. EC SHALL COORDINATE ELECTRIC WATER COOLER RECEPTACLE PLACEMENT SUCH THAT THE
RECEPTACLE IS ACCESSIBLE WITHIN THE WATER COOLER SHROUD, YET CONCEALED BY THE SHROUD PER NEC 422.33(A). PROVIDE 5mA GFCI CIRCUIT BREAKER IN ELECTRICAL PANEL PER NEC SECTION 422.
43. THE POWER AND CONTROL REQUIREMENTS FOR ALL EQUIPMENT CONNECTIONS SHALL BE CONFIRMED WITH APPROVED SHOP DRAWINGS PRIOR TO ELECTRICAL ROUGH-IN. FINAL POWER REQUIREMENTS, DIMENSIONED ROUGH-IN LOCATIONS, LOW VOLTAGE SYSTEM CONNECTIONS, ETC. SHALL BE CONFIRMED
AND MODIFIED AS REQUIRED.
44. ALL DEVICES IN OR ABOVE COUNTERS SHALL HAVE LOCATIONS AND MOUNTING HEIGHTS CONFIRMED WITH ARCHITECTURAL ELEVATIONS & OWNER PRIOR TO ROUGH-IN. ANY ADJUSTMENTS TO MOUNTING
HEIGHTS REQUIRED BY LACK OF COORDINATION WILL BE AT THE CONTRACTOR'S EXPENSE.
45. ALL EXISTING ELECTRICAL SERVICES NOT SPECIFICALLY INDICATED TO BE REMOVED OR ALTERED SHALL
REMAIN AS THEY PRESENTLY EXIST.
46. G.C. SHALL INCLUDE IN THEIR COST THE REMOVAL OF ALL EXISTING ELECTRICAL DEVICES, CONDUITS, FIXTURES AND EQUIPMENT. TURN EQUIPMENT OVER TO OWNER AS INDICATED OR RECYCLE/DISCARD ALL EQUIPMENT AS REQUIRED. E.C. SHALL BE RESPONSIBLE FOR DISCONNECTING PRIMARY SERVICE AND
TEMPORARY POWER.
47. WHERE EXISTING CEILINGS ARE REVISED FROM ACCESSIBLE TO NON-ACCESSIBLE, CONTRACTOR IS TO INCLUDE IN THEIR BID THE COSTS ASSOCIATED WITH RELOCATING ALL ELECTRICAL EQUIPMENT REQUIRING ACCESS ABOVE THE EXISTING CEILING TO A NEW ACCESSIBLE CEILING LOCATION APPROVED BY ARCHITECT AND ENGINEER. THE USE OF ACCESS PANELS IN THE NEW CEILING TO AVOID RELOCATION
OF THIS EQUIPMENT IS NOT ACCEPTABLE.
48. CONTRACTOR TO CONDUCT FUNCTIONAL TESTING OF LIGHTING CONTROLS EQUIPMENT AS REQUIRED BY COBECC 2024, SECTION C408.3. AFTER THIS TESTING IS OBSERVED AND COMPLETED, THE REGISTERED DESIGN PROFESSIONAL OR COMMISSIONING AUTHORITY SHALL PROVIDE DOCUMENTATION TO THE AHJ THAT CERTIFIES THAT THE INSTALLATION MEETS THE DOCUMENTED PERFORMANCE CRITERIA OF SECTION C405. TO INQUIRE ABOUT CERTIFIED COMMISSIONING SERVICES PROVIDED BY AE DESIGN, INC.
CALL (303) 296-3034.
49. IDENTIFY EACH RECEPTACLE WITH PANELBOARD IDENTIFICATION AND CIRCUIT NUMBER. USE HOT, STAMPED, OR ENGRAVED MACHINE PRINTING WITH BLACK-FILLED LETTERING ON FACE OF PLATE, AND
DURABLE WIRE MARKERS OR TAGS INSIDE OUTLET BOXES.
50. UNLESS OTHERWISE NOTED, ALL GFCI RECEPTACLES SHALL HAVE TEST/RESET SWITCHES INTEGRAL TO
RECEPTACLE DEVICE.
APPLICABLE CODES
ELECTRICAL
2023 NATIONAL ELECTRICAL CODE (NEC) (NFPA 70)
BUILDING
2021 INTERNATIONAL BUILDING CODE (IBC)
2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC)
ENERGY
2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
FIRE
2021 INTERNATIONAL FIRE CODE (IFC)
LOCAL
2024 CITY OF BOULDER ENERGY CONSERVATION CODE
ABBREVIATIONS
A AMPERE(S)
AC ABOVE COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERES INTERRUPTING CAPACITY
ATS AUTOMATIC TRANSFER SWITCH
BFF BELOW FINISHED FLOOR
BOF BOTTOM OF FIXTURE
C CONDUIT
CATV CABLE TELEVISION
CB CIRCUIT BREAKER
CCT CORRELATED COLOR TEMPERATURE
CLG CEILING
CT CURRENT TRANSFORMER
DED DEDICATED CIRCUIT
DISC DISCONNECT
DW DISHWASHER
DWG(S) DRAWING(S)
(E) EXISTING TO REMAIN
EC ELECTRICAL CONTRACTOR
EF EXHAUST FAN
(ER) EXISTING TO BE RELOCATED
EM EMERGENCY
EPO EMERGENCY POWER OFF
EWC ELECTRIC WATER COOLER
F FUSE
FLA FULL LOAD AMPS
GD GARBAGE DISPOSAL
G GROUND
GC GENERAL CONTRACTOR
GFI GROUND FAULT CIRCUIT INTERRUPTER
HP HORSEPOWER
IDF INTERMEDIATE DISTRIBUTION FACILITY
IG ISOLATED GROUND
ISC SHORT CIRCUIT CURRENT
KVA KILOVOLT AMPERE(S)
KW KILOWATT(S)
LTG LIGHTING
MCA MINIMUM CIRCUIT AMPERE(S)
MCB MAIN CIRCUIT BREAKER
MDP MAIN DISTRIBUTION CENTER
MDF MAIN DISTRIBUTION FACILITY
MLO MAIN LUGS ONLY
MTS MANUAL TRANSFER SWITCH
MW MICROWAVE
NC NORMALLY CLOSED
NL NIGHT LIGHT - SEE GENERAL NOTES
NO NORMALLY OPEN
OAE OR APPROVED EQUAL
OFH OVERALL FIXTURE HEIGHT
OH OVERHEAD
P POLE
PART PARTIAL CIRCUIT
PH PHASE
PNL PANEL
(R) REMOVED, EXISTING TO BE REMOVED
RCPT RECEPTACLE
REF REFRIGERATOR
RFD RECESSED FIXTURE DEPTH
(RL) RELOCATED LOCATION
SPD SURGE PROTECTION DEVICE
UC UNDER COUNTER/CABINET
UG UNDERGROUND
UON UNLESS OTHERWISE NOTED
V VOLT(S)
W WATT(S) OR WIRE
WFD WALL FIXTURE DEPTH
WG WIRE GUARD
WP WEATHERPROOF
XFMR TRANSFORMER
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/3 /2
:1
:3
P M
A u to d e s k D o c s /1
.0
B o u ld e r C o u n ty C o m m u n it y H u b
/6
.0
B o u ld e r
C o m m u n it y H u b
E
.r v t
B O
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
B ou ld er
, C o
125020.00
20251031
100% CD
ELECTRICAL COVER
SHEET
E-000AE DESIGN
Integrated Lighting, Technology, and Electrical Solutions
1900 Wazee Street #205 Denver, CO 80202 303.296.3034 aedesign-inc.com Project #: 6961.00
NO DATE DESCRIPTION
10/30/2025
6.0'
.4
.7
2.5'
2.7'
0.5'
(SEE NOTE 21)
.3 ' 1.
.0
38.4'
38.5'
92.7'
92.6'
101.5'
.9
.8
.1
BM
EXIT
J J
ET1
J
(E)
(E) (E)
(E)
(E)
(E)
EM1
HHV- 4
EM1
HHV- 4
EM1
HHV- 4
EM1
HHV- 4
EM1
HHV- 4
EM1
HHV- 4
EM1
HHV- 4
EM1
HHV- 4
EM1
HHV- 4
EM1
HHV- 4
EPO
HLV-4
GFI
WP
(N) 50KW GENERATOR
(N) UTILITY XFMR
4LS1-10,12
LS1-1
(TYP ALL EM1)
LS1-3
SITE GENERAL NOTES
A. UNDERGROUND SITE LIGHTING BRANCH CIRCUITS INCLUDING THE EQUIPMENT
GROUNDING CONDUCTOR SHALL BE UPSIZED TO ACCOMMODATE VOLTAGE DROP PER NEC
250.122(B). RUN (2#10, & 1#10G)1"C FOR A 20A BRANCH CIRCUIT.
NORTH
3/32" = 1'-0"E-010
ELECTRICAL SITE PLAN1
KEYNOTE LEGEND
KEY VALUE KEYNOTE TEXT
1 EC SHALL INSTALL NEW FIXTURE IN EXISTING LOCATION. PROVIDE NEW CONTROLS
AS INDICATED.
2 EC SHALL PROVIDE 120V, 20A POWER CONNECTION TO GENERATOR BATTERY
CHARGER. CONFIRM FINAL ELECTRICAL CONNECTION REQUIREMENTS WITH
APPROVED SHOP DRAWINGS PRIOR TO ROUGH-IN.
3 EC SHALL PROVIDE 208V, 30A, 1PH POWER CONNECTION TO GENERATOR BLOCK
HEATER, FED WITH 2#10, 1#10G, 1"C. CONFIRM FINAL ELECTRICAL CONNECTION
REQUIREMENTS WITH APPROVED SHOP DRAWINGS PRIOR TO ROUGH-IN.
4 ANTICIPATED LOCATION OF NEW 480/277V, 3-PHASE PAD MOUNTED UTILITY
TRANSFORMER. IT IS ANTICIPATED THAT UTILITY, XCEL ENERGY (XCEL) WILL RE-USE
ALL PRIMARY CONDUIT AND FEEDER BETWEEN UTILITY CONNECTION AND THE
TRANSFORMER. THE EC SHALL EXTEND EXISTING CONDUIT AND FEEDER FROM
UTILITY XFMR TO 'MDP' AS NECESSARY. COORDINATE ROUTING AND TERMINATION IN
THE FIELD AS TO ACHIEVE BUILDING POWER ACTIVATION. XCEL SHALL MAKE ALL
CONNECTIONS OF PRIMARY AND SECONDARY CABLING AT THE TRANSFORMER
LANDINGS. THE EC SHALL FURNISH AND INSTALL THE REQUIRED METER HOUSING AS
COORDINATED WITH XCEL. XCEL SHALL FURNISH, INSTALL, AND CONNECT THE
METER IN THAT HOUSING. ALL COSTS FOR WORK DESCRIBED ABOVE TO BE
PERFORMED BY XCEL SHALL BE CARRIED AS PART OF THE PROJECT BUDGET AND
SHALL BE PAID BY THE CONTRACTOR. TRANSFORMER CONCRETE PAD BY GC,
COORDINATE PAD AND CLEARANCE REQUIREMENTS WITH XCEL.
5 EC SHALL PROVIDE 120V, 20A POWER CONNECTION TO WARMING PAD. CONFIRM
FINAL ELECTRICAL CONNECTION REQUIREMENTS WITH APPROVED SHOP DRAWINGS
PRIOR TO ROUGH-IN.
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/3 /2
:1
:3
P M
A u to d e s k D o c s /1
.0
B o u ld e r C o u n ty C o m m u n it y H u b
/6
.0
B o u ld e r
C o m m u n it y H u b
E
.r v t
B O
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
B ou ld er
, C o
125020.00
20251031
100% CD
ELECTRICAL SITE PLAN
E-010AE DESIGN
Integrated Lighting, Technology, and Electrical Solutions
1900 Wazee Street #205 Denver, CO 80202 303.296.3034 aedesign-inc.com Project #: 6961.00
UP
UP
DO
W
N
UP
Stair #2
Stair #1
Lobby
Equip.
Elevator
Elevator Stair #3
Storage
Parking Bicycle
Stair #5
Parking
Valve Room
Equipment Electrical Protection
Fire
UH
0-01
UH
0-02
2 7 10
L
M
8 954
B
J
C
K
1 3 11
H
G
D
E
F
A
(R) MDP
(R) UTILITY XFMR1
(E) (E)
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/3 /2
:1
:3
P M
A u to d e s k D o c s /1
.0
B o u ld e r C o u n ty C o m m u n it y H u b
/6
.0
B o u ld e r
C o m m u n it y H u b
E
.r v t
B O
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
B ou ld er
, C o
125020.00
20251031
100% CD
ELECTRICAL DEMOLITION
POWER PLAN - LL
PARKING GARAGE
ED-100AE DESIGN
Integrated Lighting, Technology, and Electrical Solutions
1900 Wazee Street #205 Denver, CO 80202 303.296.3034 aedesign-inc.com Project #: 6961.00
NORTH
1/8" = 1'-0"ED-100
ELECTRICAL DEMOLITION POWER PLAN - LL PARKING GARAGE1
ELECTRICAL DEMOLITION REQUIREMENTS
THE BASIS OF THESE DRAWINGS WERE SITE OBSERVATIONS, ORIGINAL BUILDING
DRAWINGS AND VARIOUS OTHER SOURCES. EVERY ATTEMPT HAS BEEN MADE TO
DOCUMENT THE ACTUAL CONDITIONS. HOWEVER, THE CONTRACTOR SHALL
CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, AND
THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS, THE BUILDING'S
EXISTING CONDITION AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO
DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE
CONTRACT.
THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/OWNER OF
ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN
VIOLATION OF LAWS, ORDINANCES, RULES OR REGULATIONS OF AUTHORITIES
HAVING JURISDICTION.
THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN THEIR COST THE REMOVAL OF ALL
EXISTING ELECTRICAL DEVICES, CONDUITS, FIXTURES AND EQUIPMENT. DISCARD ALL
EQUIPMENT AS REQUIRED, UNLESS NOTED OTHERWISE.
EXISTING DEVICES NOTED AS EXISTING (E) OR INDICATED ON PLANS SHALL REMAIN,
AS THEY PRESENTLY EXIST. FOR DEMOLISHED DEVICES IN WALLS WHICH ARE TO
REMAIN, THE ELECTRICAL CONTRACTOR SHALL INSTALL A BLANK FACE PLATE ON
THE BACKBOX. FOR DEMOLISHED DEVICES INSTALLED IN THE FLOOR, THE ELECTRICAL
CONTRACTOR SHALL CUT THE FLOOR BOX FLUSH WITH THE FLOOR AND FILL WITH
CONCRETE; COORDINATE WITH THE GENERAL CONTRACTOR.
THE DEMOLITION OF SOME DEVICES MAY INTERRUPT POWER TO DEVICES DOWN
STREAM. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REWORKING THESE
CIRCUITS TO MAINTAIN POWER TO THE DOWN STREAM DEVICES WHICH WILL REMAIN.
ALL UNENERGIZED/DEMOLISHED CIRCUITRY SHALL HAVE THE CONDUCTORS REMOVED
FROM THE CONDUIT AND THE CONDUIT SHALL BE MARKED "EMPTY" WITH INDELIBLE
MARKER.
KEYNOTE LEGEND
KEY VALUE KEYNOTE TEXT
1 EXISTING SWITCHBOARD SHALL DEMOLISHED AND REPLACED WITH NEW IN SAME LOCATION
TO ACCOMMODATE NEW ELECTRICAL DISTRIBUTION AND METERING CONFIGURATION. REFER
TO NEW ELECTRICAL ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION ON NEW
ELECTRICAL DISTRIBUTION SYSTEMS AND REQUIREMENTS. CONTRACTOR SHALL COORDINATE
EXACT TIMING OF DEMOLITION AND REMOVAL OF EXISTING ELECTRICAL SWITCHBOARD WITH
OVERALL CONSTRUCTION SCHEDULE AND INSTALLATION OF NEW SWITCHBOARD EQUIPMENT
REPLACEMENT.
FPB
1-23
FPB
1-02
FPB
1-05
FPB
1-06
FPB
1-07
FPB
1-08
FPB
1-09
FPB
1-14
FPB
1-16
FPB
1-20
FPB
1-22
FPB
1-19
FPB
1-21
FPB
1-13
D O
W N
D O
W N
U P
2 7 10
L
M
8 954
B
J
C
K
1 3 11
H
G
D
E
F
A
(R) PANEL 'LV1'(R) PANEL 'HV1'
(R) PANEL 'L134'
(R) PANEL 'H134'
(R) XFMR 'TLV1'
(R) PANEL 'HHV'
(R) PANEL 'HLV'
(R) PANEL 'LV1-A'
(R) PANEL 'LV1A-2'
(R) PANEL 'LVA1-1'
(R) XFMR 'TL134'
(R) XFMR 'TLV1A1'
(R)
(R)
(E)
(R) XFMR 'SUSPENDED XFMR 'THLV'
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)(E) (E)
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/3 /2
:1
:3
P M
A u to d e s k D o c s /1
.0
B o u ld e r C o u n ty C o m m u n it y H u b
/6
.0
B o u ld e r
C o m m u n it y H u b
E
.r v t
B O
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
B ou ld er
, C o
125020.00
20251031
100% CD
ELECTRICAL DEMOLITION
POWER PLAN - LEVEL 1
ED-101AE DESIGN
Integrated Lighting, Technology, and Electrical Solutions
1900 Wazee Street #205 Denver, CO 80202 303.296.3034 aedesign-inc.com Project #: 6961.00
NORTH
1/8" = 1'-0"ED-101
ELECTRICAL DEMOLITION POWER PLAN - LEVEL 11
NO DATE DESCRIPTION
ELECTRICAL DEMOLITION REQUIREMENTS
THE BASIS OF THESE DRAWINGS WERE SITE OBSERVATIONS, ORIGINAL BUILDING
DRAWINGS AND VARIOUS OTHER SOURCES. EVERY ATTEMPT HAS BEEN MADE TO
DOCUMENT THE ACTUAL CONDITIONS. HOWEVER, THE CONTRACTOR SHALL
CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, AND
THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS, THE BUILDING'S
EXISTING CONDITION AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO
DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE
CONTRACT.
THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/OWNER OF
ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN
VIOLATION OF LAWS, ORDINANCES, RULES OR REGULATIONS OF AUTHORITIES
HAVING JURISDICTION.
THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN THEIR COST THE REMOVAL OF ALL
EXISTING ELECTRICAL DEVICES, CONDUITS, FIXTURES AND EQUIPMENT. DISCARD ALL
EQUIPMENT AS REQUIRED, UNLESS NOTED OTHERWISE.
EXISTING DEVICES NOTED AS EXISTING (E) OR INDICATED ON PLANS SHALL REMAIN,
AS THEY PRESENTLY EXIST. FOR DEMOLISHED DEVICES IN WALLS WHICH ARE TO
REMAIN, THE ELECTRICAL CONTRACTOR SHALL INSTALL A BLANK FACE PLATE ON
THE BACKBOX. FOR DEMOLISHED DEVICES INSTALLED IN THE FLOOR, THE ELECTRICAL
CONTRACTOR SHALL CUT THE FLOOR BOX FLUSH WITH THE FLOOR AND FILL WITH
CONCRETE; COORDINATE WITH THE GENERAL CONTRACTOR.
THE DEMOLITION OF SOME DEVICES MAY INTERRUPT POWER TO DEVICES DOWN
STREAM. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REWORKING THESE
CIRCUITS TO MAINTAIN POWER TO THE DOWN STREAM DEVICES WHICH WILL REMAIN.
ALL UNENERGIZED/DEMOLISHED CIRCUITRY SHALL HAVE THE CONDUCTORS REMOVED
FROM THE CONDUIT AND THE CONDUIT SHALL BE MARKED "EMPTY" WITH INDELIBLE
MARKER.
KEYNOTE LEGEND
KEY VALUE KEYNOTE TEXT
1 EC SHALL DEMOLISH ALL EXISTING POWER AND DATA DEVICES WITHIN THIS AREA, UNLESS
NOTED OTHERWISE. DISCONNECT AND REMOVE ALL ASSOCIATED UN-USED CONDUIT,
CONDUCTORS, AND CABLING BACK TO SOURCE. REFER TO DEMOLITION REQUIREMENTS, THIS
SHEET.
DN
WH
FPB
2-09
FPB
2-08
FPB
2-14
FPB
2-17
FPB
2-18
FPB
2-19
FPB
2-20FPB
2-22
FPB
2-23
FPB
2-04
FPB
2-05
2 7 10
L
M
8 954
B
J
C
K
1 3 11
H
G
D
E
F
A
OUTDOOR PATIO
A
(R) PANEL 'LV2A'(R) PANEL 'HV2'
(R) SUSPENDED XFMR 'TLV2B'
(R) XFMR 'TLV2A'
(R) PANEL 'LV2B'
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R) (R)
(R)
(R)
(R)
(R)
(R)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)(E)
(E)
(E)
(E)
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/3 /2
:1
:3
P M
A u to d e s k D o c s /1
.0
B o u ld e r C o u n ty C o m m u n it y H u b
/6
.0
B o u ld e r
C o m m u n it y H u b
E
.r v t
B O
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
B ou ld er
, C o
125020.00
20251031
100% CD
ELECTRICAL DEMOLITION
POWER PLAN - LEVEL 2
ED-102AE DESIGN
Integrated Lighting, Technology, and Electrical Solutions
1900 Wazee Street #205 Denver, CO 80202 303.296.3034 aedesign-inc.com Project #: 6961.00
NORTH
1/8" = 1'-0"ED-102
ELECTRICAL DEMOLITION POWER PLAN - LEVEL 21
NO DATE DESCRIPTION
ELECTRICAL DEMOLITION REQUIREMENTS
THE BASIS OF THESE DRAWINGS WERE SITE OBSERVATIONS, ORIGINAL BUILDING
DRAWINGS AND VARIOUS OTHER SOURCES. EVERY ATTEMPT HAS BEEN MADE TO
DOCUMENT THE ACTUAL CONDITIONS. HOWEVER, THE CONTRACTOR SHALL
CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, AND
THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS, THE BUILDING'S
EXISTING CONDITION AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO
DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE
CONTRACT.
THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/OWNER OF
ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN
VIOLATION OF LAWS, ORDINANCES, RULES OR REGULATIONS OF AUTHORITIES
HAVING JURISDICTION.
THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN THEIR COST THE REMOVAL OF ALL
EXISTING ELECTRICAL DEVICES, CONDUITS, FIXTURES AND EQUIPMENT. DISCARD ALL
EQUIPMENT AS REQUIRED, UNLESS NOTED OTHERWISE.
EXISTING DEVICES NOTED AS EXISTING (E) OR INDICATED ON PLANS SHALL REMAIN,
AS THEY PRESENTLY EXIST. FOR DEMOLISHED DEVICES IN WALLS WHICH ARE TO
REMAIN, THE ELECTRICAL CONTRACTOR SHALL INSTALL A BLANK FACE PLATE ON
THE BACKBOX. FOR DEMOLISHED DEVICES INSTALLED IN THE FLOOR, THE ELECTRICAL
CONTRACTOR SHALL CUT THE FLOOR BOX FLUSH WITH THE FLOOR AND FILL WITH
CONCRETE; COORDINATE WITH THE GENERAL CONTRACTOR.
THE DEMOLITION OF SOME DEVICES MAY INTERRUPT POWER TO DEVICES DOWN
STREAM. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REWORKING THESE
CIRCUITS TO MAINTAIN POWER TO THE DOWN STREAM DEVICES WHICH WILL REMAIN.
ALL UNENERGIZED/DEMOLISHED CIRCUITRY SHALL HAVE THE CONDUCTORS REMOVED
FROM THE CONDUIT AND THE CONDUIT SHALL BE MARKED "EMPTY" WITH INDELIBLE
MARKER.
KEYNOTE LEGEND
KEY VALUE KEYNOTE TEXT
1 EC SHALL DEMOLISH ALL EXISTING POWER AND DATA DEVICES WITHIN THIS AREA, UNLESS
NOTED OTHERWISE. DISCONNECT AND REMOVE ALL ASSOCIATED UN-USED CONDUIT,
CONDUCTORS, AND CABLING BACK TO SOURCE. REFER TO DEMOLITION REQUIREMENTS, THIS
SHEET.
UP
DO
W
N
UP
Stair #2
Stair #1
Lobby
Equip.
Elevator
Elevator Stair #3
Storage
Parking Bicycle
Stair #5
Parking
Valve Room
Equipment Electrical Protection
Fire
2.29
2 7 10
L
M
8 954
B
J
C
K
1 3 11
H
G
D
E
F
A
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(E)(E)(E)(E)(E)(E)
(E)
(E)
(E)
(E)
(E)
(R)
(R)
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/3 /2
:1
:4
P M
A u to d e s k D o c s /1
.0
B o u ld e r C o u n ty C o m m u n it y H u b
/6
.0
B o u ld e r
C o m m u n it y H u b
E
.r v t
B O
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
B ou ld er
, C o
125020.00
20251031
100% CD
ELECTRICAL DEMOLITION
LIGHTING PLAN - LL
PARKING GARAGE
ED-200AE DESIGN
Integrated Lighting, Technology, and Electrical Solutions
1900 Wazee Street #205 Denver, CO 80202 303.296.3034 aedesign-inc.com Project #: 6961.00
KEYNOTE LEGEND
KEY VALUE KEYNOTE TEXT
1 LIGHTING AND CONTROLS IN THIS ROOM ARE EXISTING TO REMAIN.
NORTH
1/8" = 1'-0"ED-200
ELECTRICAL DEMOLITION LIGHTING PLAN - LL PARKING GARAGE1
ELECTRICAL DEMOLITION REQUIREMENTS
THE BASIS OF THESE DRAWINGS WERE SITE OBSERVATIONS, ORIGINAL BUILDING
DRAWINGS AND VARIOUS OTHER SOURCES. EVERY ATTEMPT HAS BEEN MADE TO
DOCUMENT THE ACTUAL CONDITIONS. HOWEVER, THE CONTRACTOR SHALL
CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, AND
THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS, THE BUILDING'S
EXISTING CONDITION AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO
DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE
CONTRACT.
THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/OWNER OF
ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN
VIOLATION OF LAWS, ORDINANCES, RULES OR REGULATIONS OF AUTHORITIES
HAVING JURISDICTION.
THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN THEIR COST THE REMOVAL OF ALL
EXISTING ELECTRICAL DEVICES, CONDUITS, FIXTURES AND EQUIPMENT. DISCARD ALL
EQUIPMENT AS REQUIRED, UNLESS NOTED OTHERWISE.
EXISTING DEVICES NOTED AS EXISTING (E) OR INDICATED ON PLANS SHALL REMAIN,
AS THEY PRESENTLY EXIST. FOR DEMOLISHED DEVICES IN WALLS WHICH ARE TO
REMAIN, THE ELECTRICAL CONTRACTOR SHALL INSTALL A BLANK FACE PLATE ON
THE BACKBOX. FOR DEMOLISHED DEVICES INSTALLED IN THE FLOOR, THE ELECTRICAL
CONTRACTOR SHALL CUT THE FLOOR BOX FLUSH WITH THE FLOOR AND FILL WITH
CONCRETE; COORDINATE WITH THE GENERAL CONTRACTOR.
THE DEMOLITION OF SOME DEVICES MAY INTERRUPT POWER TO DEVICES DOWN
STREAM. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REWORKING THESE
CIRCUITS TO MAINTAIN POWER TO THE DOWN STREAM DEVICES WHICH WILL REMAIN.
ALL UNENERGIZED/DEMOLISHED CIRCUITRY SHALL HAVE THE CONDUCTORS REMOVED
FROM THE CONDUIT AND THE CONDUIT SHALL BE MARKED "EMPTY" WITH INDELIBLE
MARKER.
FPB
1-23
FPB
1-02
FPB
1-05
FPB
1-06
FPB
1-07
FPB
1-08
FPB
1-09
FPB
1-14
FPB
1-16
FPB
1-20
FPB
1-22
FPB
1-19
FPB
1-21
FPB
1-13
D O
W N
D O
W N
U P
2 7 10
L
M
8 954
B
J
C
K
1 3 11
H
G
D
E
F
A
2 7 10
L
M
8 954
B
J
C
K
1 3 11
H
G
D
E
F
A
(ER) P3 (ER) P3
(ER) P3
(ER) P3
(R)3
(R)
(R)
(R)(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)(R)(R) (R) (R) (R)
(R)
(R)(R)(R) (R) (R) (R)(R) (R)
(R)
(R)
(R)
(R)
(R)
(ER) L1(ER) L1 (ER) L1 (ER) L1 (ER) L1 (ER) L1 (ER) L1
(ER) L1
(ER) P1
(ER) P2
(ER) L2
(ER) L2
(ER) L2
(ER) L2
(ER) L2 (ER) L2
(ER) L2
(ER) L3 (ER) L3(ER) L3
(ER) L3
(ER) L3
ELECTRICAL ROOM
EX03
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/3 /2
:1
:4
P M
A u to d e s k D o c s /1
.0
B o u ld e r C o u n ty C o m m u n it y H u b
/6
.0
B o u ld e r
C o m m u n it y H u b
E
.r v t
B O
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
B ou ld er
, C o
125020.00
20251031
100% CD
ELECTRICAL DEMOLITION
LIGHTING PLAN - LEVEL 1
ED-201AE DESIGN
Integrated Lighting, Technology, and Electrical Solutions
1900 Wazee Street #205 Denver, CO 80202 303.296.3034 aedesign-inc.com Project #: 6961.00
KEYNOTE LEGEND
KEY VALUE KEYNOTE TEXT
1 EC SHALL DEMOLISH ALL EXISTING LIGHTING AND CONTROLS WITHIN THIS AREA,
UNLESS NOTED OTHERWISE. DISCONNECT AND REMOVE ALL ASSOCIATED UN-USED
CONDUIT, CONDUCTORS, AND CABLING BACK TO SOURCE. REFER TO DEMOLITION
REQUIREMENTS, THIS SHEET.
2 LIGHTING AND CONTROLS IN THIS ROOM ARE EXISTING TO REMAIN.
3 FIXTURE SHALL BE REMOVED AND SAVED FOR FUTURE USE.
NORTH
1/8" = 1'-0"ED-201
ELECTRICAL DEMOLITION LIGHTING PLAN - LEVEL 11
ELECTRICAL DEMOLITION REQUIREMENTS
THE BASIS OF THESE DRAWINGS WERE SITE OBSERVATIONS, ORIGINAL BUILDING
DRAWINGS AND VARIOUS OTHER SOURCES. EVERY ATTEMPT HAS BEEN MADE TO
DOCUMENT THE ACTUAL CONDITIONS. HOWEVER, THE CONTRACTOR SHALL
CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, AND
THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS, THE BUILDING'S
EXISTING CONDITION AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO
DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE
CONTRACT.
THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/OWNER OF
ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN
VIOLATION OF LAWS, ORDINANCES, RULES OR REGULATIONS OF AUTHORITIES
HAVING JURISDICTION.
THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN THEIR COST THE REMOVAL OF ALL
EXISTING ELECTRICAL DEVICES, CONDUITS, FIXTURES AND EQUIPMENT. DISCARD ALL
EQUIPMENT AS REQUIRED, UNLESS NOTED OTHERWISE.
EXISTING DEVICES NOTED AS EXISTING (E) OR INDICATED ON PLANS SHALL REMAIN,
AS THEY PRESENTLY EXIST. FOR DEMOLISHED DEVICES IN WALLS WHICH ARE TO
REMAIN, THE ELECTRICAL CONTRACTOR SHALL INSTALL A BLANK FACE PLATE ON
THE BACKBOX. FOR DEMOLISHED DEVICES INSTALLED IN THE FLOOR, THE ELECTRICAL
CONTRACTOR SHALL CUT THE FLOOR BOX FLUSH WITH THE FLOOR AND FILL WITH
CONCRETE; COORDINATE WITH THE GENERAL CONTRACTOR.
THE DEMOLITION OF SOME DEVICES MAY INTERRUPT POWER TO DEVICES DOWN
STREAM. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REWORKING THESE
CIRCUITS TO MAINTAIN POWER TO THE DOWN STREAM DEVICES WHICH WILL REMAIN.
ALL UNENERGIZED/DEMOLISHED CIRCUITRY SHALL HAVE THE CONDUCTORS REMOVED
FROM THE CONDUIT AND THE CONDUIT SHALL BE MARKED "EMPTY" WITH INDELIBLE
MARKER.
2 7 10
L
M
8 954
B
J
C
K
1 3 11
H
G
D
E
F
A
(E) (E)
(E)
(E)
(E) (E) (E)
(ER) P3 (ER) P3
(R)
(R)
3(R)3
(R)
(R)
(R) (R)
(R)
(ER) D2
(ER) D2
(ER) D2
(ER) D2
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/3 /2
:1
:4
P M
A u to d e s k D o c s /1
.0
B o u ld e r C o u n ty C o m m u n it y H u b
/6
.0
B o u ld e r
C o m m u n it y H u b
E
.r v t
B O
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
B ou ld er
, C o
125020.00
20251031
100% CD
ELECTRICAL DEMOLITION
LIGHTING PLAN - LEVEL 2
ED-202AE DESIGN
Integrated Lighting, Technology, and Electrical Solutions
1900 Wazee Street #205 Denver, CO 80202 303.296.3034 aedesign-inc.com Project #: 6961.00
KEYNOTE LEGEND
KEY VALUE KEYNOTE TEXT
1 EC SHALL DEMOLISH ALL EXISTING LIGHTING AND CONTROLS WITHIN THIS AREA,
UNLESS NOTED OTHERWISE. DISCONNECT AND REMOVE ALL ASSOCIATED UN-USED
CONDUIT, CONDUCTORS, AND CABLING BACK TO SOURCE. REFER TO DEMOLITION
REQUIREMENTS, THIS SHEET.
2 LIGHTING AND CONTROLS IN THIS ROOM ARE EXISTING TO REMAIN.
3 FIXTURE SHALL BE REMOVED AND SAVED FOR FUTURE USE.
NORTH
1/8" = 1'-0"ED-202
ELECTRICAL DEMOLITION LIGHTING PLAN - LEVEL 21
ELECTRICAL DEMOLITION REQUIREMENTS
THE BASIS OF THESE DRAWINGS WERE SITE OBSERVATIONS, ORIGINAL BUILDING
DRAWINGS AND VARIOUS OTHER SOURCES. EVERY ATTEMPT HAS BEEN MADE TO
DOCUMENT THE ACTUAL CONDITIONS. HOWEVER, THE CONTRACTOR SHALL
CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, AND
THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS, THE BUILDING'S
EXISTING CONDITION AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO
DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE
CONTRACT.
THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/OWNER OF
ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN
VIOLATION OF LAWS, ORDINANCES, RULES OR REGULATIONS OF AUTHORITIES
HAVING JURISDICTION.
THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN THEIR COST THE REMOVAL OF ALL
EXISTING ELECTRICAL DEVICES, CONDUITS, FIXTURES AND EQUIPMENT. DISCARD ALL
EQUIPMENT AS REQUIRED, UNLESS NOTED OTHERWISE.
EXISTING DEVICES NOTED AS EXISTING (E) OR INDICATED ON PLANS SHALL REMAIN,
AS THEY PRESENTLY EXIST. FOR DEMOLISHED DEVICES IN WALLS WHICH ARE TO
REMAIN, THE ELECTRICAL CONTRACTOR SHALL INSTALL A BLANK FACE PLATE ON
THE BACKBOX. FOR DEMOLISHED DEVICES INSTALLED IN THE FLOOR, THE ELECTRICAL
CONTRACTOR SHALL CUT THE FLOOR BOX FLUSH WITH THE FLOOR AND FILL WITH
CONCRETE; COORDINATE WITH THE GENERAL CONTRACTOR.
THE DEMOLITION OF SOME DEVICES MAY INTERRUPT POWER TO DEVICES DOWN
STREAM. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REWORKING THESE
CIRCUITS TO MAINTAIN POWER TO THE DOWN STREAM DEVICES WHICH WILL REMAIN.
ALL UNENERGIZED/DEMOLISHED CIRCUITRY SHALL HAVE THE CONDUCTORS REMOVED
FROM THE CONDUIT AND THE CONDUIT SHALL BE MARKED "EMPTY" WITH INDELIBLE
MARKER.
UP
DO
W
N
UP
Stair #2
Stair #1
Lobby
Equip.
Elevator
Elevator Stair #3
Storage
Parking Bicycle
Stair #5
Parking
Valve Room
Equipment Electrical Protection
Fire
C R
UH
0-01
UH
0-02
CUH
0-02
CUH
0-01
EUH
0-01
CUH
0-03
PH
0-01
PH
0-02
PH
0-04
PH
0-03
2 7 10
L
M
8 954
B
J
C
K
1 3 11
H
G
D
E
F
A
'MDP'
'DS-PV''ATS-S1'
LV1A1-76
GFI
LV1A1-76
GFI
LV1A1-76
GFI
LV1A1-76
GFI
LV1A1-76
GFI
(E)(E)
UTILITY METER
BUILDING ENERGY SUB-METER
PV METER
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/3 /2
:1
:4
P M
A u to d e s k D o c s /1
.0
B o u ld e r C o u n ty C o m m u n it y H u b
/6
.0
B o u ld e r
C o m m u n it y H u b
E
.r v t
B O
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
B ou ld er
, C o
125020.00
20251031
100% CD
ELECTRICAL POWER
PLAN - LL PARKING
GARAGE
E-100AE DESIGN
Integrated Lighting, Technology, and Electrical Solutions
1900 Wazee Street #205 Denver, CO 80202 303.296.3034 aedesign-inc.com Project #: 6961.00
NORTH
1/8" = 1'-0"E-100
ELECTRICAL POWER PLAN - LL PARKING GARAGE1
J J J J J J J J JJ JJ J J J J
J J J J
JJJJJ
J J
J J
J J
CR
C R
CR
C R
C R
C R
C R
C R
C R
C R
C R
C R
CR
CR
CR
CR
CR
C R
CR
C R
CR
C R
C R
CR
C R
C R
C R
C R
C R
C R
C R
C R
CR
CRCR
C R
C R
C R
C R
C R
C R
CR
CR
J J
J
CR
AC
FPB
1-25
FPB
1-26
FPB
1-24
FPB
1-23
FPB
1-01
FPB
1-02
FPB
1-03
FPB
1-04
FPB
1-05
FPB
1-06
FPB
1-07
FPB
1-08
FPB
1-09
FPB
1-10
FPB
1-11
FPB
1-12
FPB
1-15
FPB
1-18
FPB
1-14
FPB
1-16
FPB
1-17
FPB
1-20
FPB
1-22
FPB
1-19
FPB
1-21
WH
RCP
J
J
J J
J J
J J
J J
J J JJ
J
J J
J J
JJJ
JJJ JJJ
JJJ JJJ JJJ JJJ JJJ JJJJJJ
JJJJJJ
J
J
J
FPB
1-13
AC
AC
LOBBY
STAIRS 3
LOBBY
OPEN OFFICE
SECURITY/MAIL ROOM
HUDDLE ROOM
JANITOR CLOSET
LARGE CONFERENCE/
WORKFORCE LAB
WORKFORCE STORAGE
ELECTRICAL ROOM
EX03
FACE TO FACE
FACE TO FACE
FACE TO FACE
FACE TO FACE
FACE TO FACE
FACE TO FACE
STAIRS 2
SERVER ROOM
HOSPITALITY
FACE TO FACE
TRAINING/BREAKOUT
TRAINING ROOM A
TRAINING ROOM B
CDEM EMER MGMT
FURNITURE STORAGE
OPEN WORK
LARGE CONFERENCE
STAIR 5
005.1
STAIR 1
001.2
W. RESTROOM
2 7 10
L
M
8 954
B
J
C
K
1 3 11
H
G
D
E
F
A
SUSPENDED XFMR 'THLV'
XFMR 'TLV1'
(E)
LV1-17
AC
GFI
LV1-16
AC
GFI
FACE TO FACE
WIC / IMM. EXAM RM
FACE TO FACE
FACE TO FACE
ENV HLTH REF STRG
WELLNESS
M. RESTROOM
ISSUANCE AND SAFE
STAFF SHOWER/RR
STAFF SHOWER/RR
FITNESS AREA
AAA / VETERANS
AAA / VETERANS
AAA / VETERANS
PUB HEALTH
VITAL RECORDS
VR STOR.
LOBBY
CDEM / EMER MGMT
FACE TO FACE
WIC / IMM. EXAM RM
PH STORAGE
BREAKROOM
ALL GENDERED
STAFF RR
LV1A1-37
AC
GFI
LV1A1-44
AC
GFI
RECEPTION
LV1-30
AC
GFI
LV1-A-20
GFI
LV1-A-20
AC
GFI
LV1-A-20
AC
GFI
LV1-A-18
AC
GFI
LV1-A-18
AC
GFI
LV1-19
AC
GFI
LV1-19
AC
GFI
LV1-20
GFI
LV1-20
GFI
LV1-A-28
AC
GFI
LV1-A-28
AC
GFI
LV1-A-29
AC
GFI
LV1-A-29
AC
GFI
LV1-27
AC
LV1-31
AC
LV1-33
AC
LV1-35
AC
FACE TO FACE
LV1-A-40
AC
LV1-A-40
AC
LV1-A-18
GFI
LV1A1-46
AC
LV1A1-46
AC
LV1A1-12
REF
LV1A1-1
REF
LV1A1-5
GD
LV1-A-30
LV1-A-30
LV1A1-71
AC
LV1A1-73
AC
BENEFITS
LV1A1-51
GFI
1 1
1 1
2 2 2 2 2 2 2 2
2 32 3
3333333 3
LV1-30
AC
GFI
L V -9
H A
R M
R E D
U C T
IO
N
LV1-8
EWC
L V -3
A C
L V -3
A C
LV1A1-14
AC
LV1A1-15
AC
LV1A1-23
VENDING
LV1A1-25
VENDING
LV1A1-43
COPY/ PRINT
PANEL 'LV1-A'
LS1-7
REF
LS1-8
REF
LS1-9
UC REF
LV1-2
COPY/ PRINT
LV1-6
COFFEE
AC
LV1-4
AC
LV1-4
AC
LV1A1-9
AC
LV1A1-6
AC LV1A1-3
COFFEE
AC
LV1A1-10
MW
LV1A1-4
MW
LV1A1-8
DW
LV1-10
DW
LV1A1-2
AC
LV1A1-53
COFFEE
AC
LV1A1-49
COPY/ PRINT
LV1A1-69
COPY/ PRINT
LV1-18
UC REF
LV1A1-70
AC
LV1A1-70
AC
PANEL 'HV1'
PANEL 'HHV'
PANEL 'LV1'
PANEL 'HLV'
PANEL 'L134'
PANEL 'H134'
PANEL 'LV1A1'
XFMR 'TLV1A1'
XFMR 'TL134'
XFMR 'TS1'
PANEL 'LS1'
AC AC
LS1-5
+48
LS1-6
+48
LS1-4
+48+84
LV1-A-33
TV
+84
LV1-A-34
TV
+84
+84
LV1A1-27
TV
+84
+84
LV1A1-45
AC
LV1A1-45
AC
LV1A1-52
PRINTER
AC
AC
LV1A1-50
SAFE
7 7
+84
LV1A1-48
TV
+84
LV1A1-16
COFFEE
AC
'DS-S1'
LV1A1-68
TR
LV1A1-68
TRLV1A1-68
TR
LV1-34
TR
LV1-34
TR
LV1A1-20
GFI
LV1A1-24
GFI
10101010101010
9 9 9 9 9
101010
FACP
(RL)
LS1- 2
12 1212
LV1-A-1
LV1-A-3
LV1-A-5
LV1-A-7
LV1-A-7
LV1-A-5
LV1-A-3
LV1-A-1
LV1-A-9
LV1-A-11
LV1-A-13
LV1-A-15
LV1-A-9
LV1-A-11
LV1-A-13
LV1-A-15
LV1-A-17
LV1-A-19
LV1-A-21
LV1-A-23
LV1-A-19
LV1-A-23
LV1-A-21
LV1-A-17 LV1-A-2
LV1-A-4
LV1-A-6
LV1-A-8
LV1-A-2
LV1-A-4
LV1-A-6
LV1-A-8
LV1-A-10
LV1-A-12
LV1-A-14
LV1-A-16
LV1-A-10
LV1-A-12
LV1-A-14
LV1-A-16
LV1A1-18
LV1A1-22 LV1A1-22 LV1A1-22
LV1A1-22
LV1A1-26
LV1A1-26
LV1A1-26
LV1A1-26
LV1A1-26
LV1A1-27
LV1A1-27
LV1-22 LV1-22
LV1-22
LV1-22 LV1-22
LV1-22
LV1-24
LV1-24
LV1-24 LV1-24
LV1-24
LV1-24
LV1-24
LV1-26
LV1-26
LV1-26
LV1-26
LV1-26
LV1-26
LV1-28
LV1-28
LV1-28
LV1-32
LV1-32
LV1-32
LV1-32
LV1-34
LV1-34
LV1-34
LV1A1-29
LV1A1-29
LV1A1-29
LV1A1-29
LV1A1-36
LV1A1-36
LV1A1-36
LV1A1-36 LV1A1-35
LV1A1-35
LV1A1-35
LV1A1-35
LV1A1-34
LV1A1-34
LV1A1-34
LV1A1-34
LV1A1-33
LV1A1-33
LV1A1-33
LV1A1-33 LV1A1-32
LV1A1-32
LV1A1-32
LV1A1-32
LV1A1-31
LV1A1-31
LV1A1-31
LV1A1-31
LV1A1-30
LV1A1-30
LV1A1-30
LV1A1-30
LV1A1-29
LV1A1-38
LV1A1-38
LV1A1-38
LV1A1-38
LV1A1-39LV1A1-40LV1A1-41LV1A1-42
LV1A1-46
LV1A1-46
LV1A1-47LV1A1-48
LV1A1-47
LV1A1-47
LV1A1-48
LV1A1-48
LV1A1-45
LV1A1-45
LV1A1-54LV1A1-54
LV1A1-54
LV1A1-51
LV1A1-51
LV1A1-51
LV1A1-51
LV1A1-55
AC
LV1A1-57
LV1A1-59
LV1A1-61
LV1A1-63
LV1A1-57
LV1A1-59
LV1A1-61
LV1A1-63LV1A1-65
LV1A1-65
LV1A1-65
LV1A1-65
LV1A1-65
LV1A1-65
LV1A1-67
EWC
LV1A1-48
LV1A1-71
LV1A1-71
LV1A1-73
LV1A1-73
LV1-11
LV1-11
LV1-11
LV1-11
LV1-11
LV1-11
LV1-12
LV1-13
LV1-14
LV1-14
LV1-14
LV1-14
LV1-14
LV1-14
LV1-15
LV1-23
LV1-23
LV1-23
LV1-27
LV1-27
LV1-31
LV1-33LV1-35
L V -3
L V -3
LV1-40
LV1-40
LV1-40
LV1-40
LV1-A-22
LV1-A-22
LV1-A-22
LV1-A-22
LV1-A-24
LV1-A-24
LV1-A-24
LV1-A-24
LV1-A-25
LV1-A-25
LV1-A-26
LV1-A-26
LV1-A-26
LV1-A-26
LV1-A-27
LV1-A-27
LV1-A-27
LV1-A-31LV1-A-31LV1-A-31
LV1-A-32
LV1-A-32
LV1-A-32
LV1-A-33LV1-A-33
LV1-A-33LV1-A-33
LV1-A-33
LV1-A-34
LV1-A-34
LV1-A-35
LV1-A-35
LV1-A-35
LV1-A-36
LV1-A-36
LV1-A-36
LV1-A-37
LV1-A-37
LV1A1-75
LV1A1-75
LV1A1-77
LV1A1-77
LV1-A-30
LV1-A-30
LV1A1-75
LV1A1-68
LV1A1-70
LV1A1-70
LV1A1-72LV1A1-72
LV1-A-38
LV1-A-38
LV1-A-38LV1-A-38LV1-A-39LV1-A-39LV1-A-39
LV1-A-40
13LV1A1-74
LV1A1-74
LV1A1-74
(RL)
+60
LV1-A-34
TV
+60
'PBB'
POWER GENERAL NOTES
KEYNOTE LEGEND
KEY VALUE KEYNOTE TEXT
1 EC SHALL PROVIDE A 6" DIA RECESSED, POKE THRU TYPE FLOOR BOX WITH ROUND
COVER. BASIS OF DESIGN IS LEGRAND - EVOLUTION #6AT2P SERIES OR APPROVED
EQUAL WITH POWER AND LOW VOLTAGE COMPARTMENTS AND DEVICES. PROVIDE
WITH FLANGED FLOOR BOX COVERS FOR ALL CARPET APPLICATIONS, AND FLUSH
TYPE COVERS FOR ALL OTHER FLOOR FINISH TYPES. EC SHALL PROVIDE 3/4" C FOR
POWER AND 1-1/2"C FOR LOW VOLTAGE CABLING RACEWAY. PROVIDE RECEPTACLE
TYPE/QUANTITY AS INDICATED ON PLAN. ROUTE CONDUIT TO ADJACENT WALL AND
UP TO ACCESSIBLE CEILING. EC SHALL VERIFY SPECIFICATION AND COVER
FINISH/TYPE WITH ARCHITECT AS PART OF THE SUBMITTAL REVIEW PROCESS. EC
SHALL COORDINATE EXACT LOCATIONS AND CONNECTION REQUIREMENTS WITH
OWNER/ARCHITECT PRIOR TO ROUGH-IN.
2 PROVIDE 4"X4" FLUSH MOUNTED JUNCTION BOX FOR POWER CONNECTION TO
OFFICE FURNITURE SYSTEM, INSTALL POWER FEED WHIP INTO JUNCTION BOX
(SUPPLIED BY SYSTEMS FURNITURE VENDOR). SYSTEMS FURNITURE BRANCH CIRCUIT
SHALL CONSIST OF 4-#10 (HOTS) + 2-#10 (NEUTRAL) AND 2-#10 (GROUND) IN A 1"
CONDUIT. ACCOMMODATIONS FOR CIRCUITING INCLUDE (1) STANDARD DEDICATED
CIRCUIT PER PAIR OF WORKSTATION SEATS. 25% OF ALL FURNITURE FEED SYSTEMS
RECEPTACLE POWER CIRCUITS SHALL BE CONTROLLED VIA OCCUPANCY SENSORS AS
REQUIRED FOR AUTOMATIC SWITCHING CONTROL PER 2021 IECC, REFER TO
LIGHTING PLANS FOR MORE INFORMATION. EC SHALL COORDINATE EXACT LOCATION
AND REQUIREMENTS WITH APPROVED FURNITURE SYSTEM SHOP DRAWINGS.
3 PROVIDE 4"X4" FLUSH MOUNTED JUNCTION BOX WITH 1-1/2"C TO ABOVE CEILING
FOR TELECOMMUNICATIONS CONDUIT RACEWAY TO FEED FURNITURE SYSTEM
LOCATIONS. COORDINATE EXACT LOCATION AND CONNECTION REQUIREMENTS WITH
APPROVED FURNITURE SYSTEM SHOP DRAWINGS PRIOR TO ROUGH-IN.
4 EC SHALL VERIFY AND COORDINATE DEVICE MOUNTING AND CONDUIT ROUTING
WITHIN CUSTOM MILLWORK WITH ARCHITECT, OWNER, GC AND MILLWORK
INSTALLER PRIOR TO ROUGH-IN.
5 EC SHALL PROVIDE DUPLEX RECEPTACLES WITHIN KITCHEN ISLAND AS INDICATED.
SAWCUT AS INDICATED AND ROUTE CONDUIT IN FLOOR BACK TO WALL TO STUB OUT
ABOVE ACCESSIBLE CEILING.
6 EC SHALL EXTEND EXISTING FEEDER TO NEW PANEL TO REPLACE EXISTING
DEMOLISHED PANEL IN NEW LOCATION.
7 EC SHALL PROVIDE FURNITURE FEED STYLE POKE-THRU, EVOLUTION SERIES (TYPE
6ATCFFBK OR EQUIVALENT), FOR POWER AND DATA PATHWAY TO FURNITURE
SYSTEM. SYSTEMS FURNITURE BRANCH CIRCUIT SHALL CONSIST OF 4#10 (HOTS) +
2#10 (NEUTRAL) AND 2#10 GROUND IN A 3/4" CONDUIT. PROVIDE 1-1/2" CONDUIT
FOR LOW VOLTAGE CABLING. SAWCUT AS INDICATED AND ROUTE CONDUIT IN FLOOR
BACK TO WALL TO STUB OUT ABOVE ACCESSIBLE CEILING. COORDINATE EXACT
LOCATION WITH APPROVED FURNITURE SYSTEM SHOP DRAWINGS AND FURNITURE
INSTALLER PRIOR TO ROUGH-IN. COORDINATE FINAL LOCATIONS WITH ARCHITECT.
25% OF ALL FURNITURE FEED SYSTEMS RECEPTACLE POWER CIRCUITS SHALL BE
CONTROLLED VIA OCCUPANCY SENSORS AS REQUIRED FOR AUTOMATIC SWITCHING
CONTROL PER 2021 IECC. REFER TO LIGHTING PLANS FOR MORE INFORMATION.
8 EC SHALL PROVIDE 120V, 20A CONNECTION TO IN WALL BOTTLE FILLING STATION.
EC SHALL CONFIRM ALL ELECTRICAL AND CONNECTION REQUIREMENTS WITH
EQUIPMENT SHOP DRAWINGS PRIOR TO ROUGH-IN.
9 EC SHALL PROVIDE JUNCTION BOX FOR SPEAK-THRU DEVICE. FIELD COORDINATE
EXACT LOCATION AND REQUIREMENTS WITH INSTALLER PRIOR TO ROUGH-IN.
10 EC SHALL PROVIDE LOW-VOLTAGE CONNECTION FOR ROOM WIZARD DEVICE.
COORDINATE LOW-VOLTAGE REQUIREMENTS WITH INSTALLER PRIOR TO ROUGH-IN.
11 WALL MOUNTED JUNCTION FOR 120V, 20A HARDWIRED DEDICATED CONNECTION TO
HAND DRYER. EC SHALL COORDINATE EXACT CONNECTION REQUIREMENTS,
MOUNTING LOCATION, AND HEIGHT WITH ARCHITECTURAL ELEVATIONS AND
APPROVED SHOP DRAWINGS PRIOR TO ROUGH-IN.
12 WALL MOUNTED JUNCTION FOR 120V, 20A HARDWIRED CONNECTION TO
LAVATORY/SINK. EC SHALL COORDINATE EXACT CONNECTION REQUIREMENTS,
MOUNTING LOCATION, AND HEIGHT WITH ARCHITECTURAL ELEVATIONS AND
APPROVED SHOP DRAWINGS PRIOR TO ROUGH-IN.
13 EC SHALL PROVIDE 120V, 20A CONNECTION FOR WHITE NOISE GENERATOR. EC
SHALL CONFIRM ELECTRICAL AND INSTALLATION REQUIREMENTS WITH SHOP
DRAWINGS PRIOR TO ROUGH-IN.
14 EC SHALL PROVIDE LOW-VOLTAGE CONNECTION FOR DURESS BUTTON. COORDINATE
LOW-VOLTAGE REQUIREMENTS WITH INSTALLER PRIOR TO ROUGH-IN.
A. EC TO INCLUDE INSTALLATION SCOPE AND CONSTRUCTION COSTS ASSOCIATED WITH
2021 IECC SECTION C405.11 REQUIREMENTS FOR CONTROLLED RECEPTACLES.
CONTROLLED RECEPTACLES ARE TO BE PROVIDED FOR ALL ENCLOSED OFFICES,
WORKSTATIONS AND CLASSROOM SPACES. A MINIMUM OF 50% OF PERMANENTLY
INSTALLED RECEPTACLES SHALL BE CONTROLLED VIA EITHER A LOCAL ROOM
CONTROLLER BASED SYSTEM USING THE LIGHTING CONTROL SENSORS, OR VIA A
LIGHTING RELAY PANEL ON TIMECLOCK CONTROLS. 25% OF FURNITURE FEED BRANCH
CIRCUITS ARE TO BE FED THROUGH THE LIGHTING RELAY PANEL TO PROVIDE A
CONTROLLED POWER CONNECTION. REFER TO DETAILS ON SHEET E8.0 FOR ADDITIONAL
INFORMATION.
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/3 /2
:1
:5
P M
A u to d e s k D o c s /1
.0
B o u ld e r C o u n ty C o m m u n it y H u b
/6
.0
B o u ld e r
C o m m u n it y H u b
E
.r v t
B O
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
B ou ld er
, C o
125020.00
20251031
100% CD
ELECTRICAL POWER
PLAN - LEVEL 1
E-101AE DESIGN
Integrated Lighting, Technology, and Electrical Solutions
1900 Wazee Street #205 Denver, CO 80202 303.296.3034 aedesign-inc.com Project #: 6961.00
NORTH
1/8" = 1'-0"E-101
ELECTRICAL POWER PLAN - LEVEL 11
WH
JJ J J J J
J
J
J
J
JJ J J
J J J JJ J
CR
CR
C R
CR
CR
C R
C R
C R
C R
J
J
J
J
J
J
CR
CR
AC
FPB
2-07
FPB
2-09
FPB
2-10
FPB
2-08
FPB
2-11
FPB
2-12
FPB
2-13
FPB
2-14
FPB
2-26
FPB
2-15
FPB
2-16
FPB
2-17
FPB
2-18
FPB
2-19
FPB
2-20FPB
2-22
FPB
2-21
FPB
2-23
FPB
2-24
FPB
2-25
FPB
2-01
FPB
2-02
FPB
2-03
FPB
2-04
FPB
2-05
FPB
2-06
J
J
J
JJ
J J
J J
J
J J
J J
J J
J
JJJ
JJJ
JJJ
JJJ
JJJ
JJJ
JJJ
JJJ
JJJ
JJJ
JJJ
JJJ
JJJ
JJJ JJJ JJJ
JJJJJJJJJJJJJJJ
J
J
J
J J
AC
2' -2
/2
2 7 10
L
M
8 954
B
J
C
K
1 3 11
H
G
D
E
F
A
STAIR 1
001.3
STAIR 5
STAIR 4
ELEVATOR LOBBY
PRINT/ EMPLOYEE
LOUNGE
JAN/ROOF
EX02
OUTDOOR PATIO
A
SMALL CONFERENCE
ELEC
OPEN WORK
FOCUS
FOCUS
OUTDOOR PATIO
B
PUBLIC HEALTH STORAGE
FOCUS
MEDIUM CONFERENCE
BCPH/WIC/NFP OPEN
STORAGE
HARM REDUCTION
STORAGE
EMER MGMT STORAGE
ENVIRONMENTAL HEALTH
STORAGE
W. RESTROOM
WELLNESS
SERVER
OPEN WORK
DHS STORAGE
DHS STORAGE
IT STORAGE
IT HELP DESK
FACILITIES STORAGE
FOCUS
CS OFFSITE EVENT AND
ADMIN STORAGE
DHS STORAGE
OPEN WORK
OPEN WORK
SMALL CONFERENCE
DEP DIRECTOR OFFICE
DEP DIRECTOR OFFICE
OPEN WORK
DEP DIRECTOR OFFICE
DEP DIRECTOR OFFICE
DEP DIRECTOR OFFICE
FOCUS
FOCUS
OPEN WORK
FOCUS
DIRECTOR OFFICE
DIRECTOR…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .