480063_GSD_WTP_Grit_Dewatering_Improvements_RTA_PLANS(20-Aug-20).pdf
PDF 16 MB Posted
- Solicitation number
- W912P620B0020
About this file
This document provides details for a federal construction contract solicitation. The United States Army Corps of Engineers - Chicago District is seeking bids to replace the existing grit dewating equipment at the Gary Sanitary District Sanitary Treatment Plant in Gary, Indiana with higher capacity and more robust equipment. The project is estimated to cost between $1,000,000 and $5,000,000. Competition for this acquisition is reserved exclusively for small businesses with a North American Industry Classification System code of 237110 and annual revenue of less than $39.5 million. Bids are due by 1:00pm Central Time on September 22, 2020. Interested parties must register with the System for Award Management and direct inquiries to the point of contact.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GARY, INDIANA
Water Environment EnergyTransportation Facilities
ISSUE DATE: 20 AUG 2020
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
GARY SANITARY DISTRICT
SOLICITATION NUMBER W912P620B0020
08/20/2020
GARY SANITARY DISTRICT
GARY, INDIANA
SOLICITATION NUMBER W912P620B0020
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
563 South Lake Street, Suite 1A
Gary, Indiana 46403
G-1
DRAWING INDEX
S-1 STRUCTURAL GENERAL NOTES
S-2 SCREEN BUILDING STRUCTURAL DEMOLITION PLAN
S-3 SCREEN BUILDING STRUCTURAL NEW WORK PLAN
S-4 DETRITOR BUILDING & ELECTRICAL ROOM STRUCTURAL DEMOLITION AND NEW WORK PLANS
S-5 STRUCTURAL SECTIONS AND DETAILS
S-6 STRUCTURAL SPECIAL INSPECTIONS I
S-7 STRUCTURAL SPECIAL INSPECTIONS II
M-1 MECHANICAL LEGEND AND ABBREVIATIONS
M-2 MECHANICAL NOTES AND PIPE AND VALVE SCHEDULES
M-3 DETRITOR BUILDING GRIT PUMPING - DEMOLITION - PLANS
M-4 SCREEN BUILDING GRIT WASHING - DEMOLITION - PLAN
M-5 DETRITOR BUILDING GRIT - NEW WORK - PLANS
M-6 DETRITOR BUILDING GRIT - NEW WORK - SECTIONS
M-7 SCREEN BUILDING GRIT WASHING - NEW WORK - PLAN
M-8 SCREEN BUILDING GRIT WASHING - NEW WORK - SECTION I
M-9 SCREEN BUILDING GRIT WASHING - NEW WORK - SECTION II
M-10 STANDARD DETAILS
SHEET NUMBER SHEET NAME
G-1 DRAWING INDEX
H-1 HVAC LEGENDS, ABBREVIATIONS, AND GENERAL NOTES
H-2 SCREEN AND DETRITOR BUILDING HVAC DEMOLITION PLAN ELEVATION 3.0'
H-3 SCREEN AND DETRITOR BUILDING HVAC DEMOLITION PLAN ELEVATIONS 12.0' AND 34.0'
H-4 SCREEN AND DETRITOR BUILDING HVAC NEW WORK PLAN ELEVATION 3.0'
H-5 SCREEN AND DETRITOR BUILDING HVAC NEW WORK PLAN ELEVATION 12.0'
H-6 SCREEN BUILDING HVAC NEW WORK PLAN ELEVATION 34.0'
H-7 DETRITOR BUILDING HVAC NEW WORK SECTIONS
H-8 BLOWER BUILDING HVAC NEW WORK PLAN
H-9 HVAC SCHEDULES
H-10 HVAC DETAILS
P-1 PLUMBING LEGENDS, ABBREVIATIONS, AND GENERAL NOTES
P-2 SCREEN BUILDING PLUMBING DEMOLITION PLANS
P-3 SCREEN BUILDING PLUMBING NEW WORK PLANS
I-1 INSTRUMENTATION LEGEND 1
I-2 SYSTEM ARCHITECTURE
I-3 PROCESS & INSTRUMENTATION DIAGRAM / GRIT REMOVAL SYSTEM
I-4 PROCESS & INSTRUMENTATION DIAGRAM / MISCELLANEOUS
SHEET NUMBER SHEET NAME
C-1 CIVIL NOTES, LEGEND, AND ABBREVIATIONS
C-2 SITE PLAN
A-1 ABBREVIATIONS, NOTES, CODE SUMMARY
A-2 SCREEN BUILDING NEW ROOF PLAN AND DETAILS
A-3 BLOWER BUILDING PLAN AND DETAILS
E-1 ELECTRICAL LEGEND, ABBREVIATIONS AND GENERAL NOTES
E-2 ELECTRICAL LEGEND, ABBREVIATIONS AND GENERAL NOTES
E-3 GENERAL ELECTRICAL NOTES
E-4 ELECTRICAL CLASSIFICATION PLAN
E-5 ELECTRICAL SITE PLAN
E-6 EXISTING 01-MCC-02 ONE-LINE DIAGRAM AND FRONT ELEVATION
E-7 01-MCC-03 ONE-LINE DIAGRAM
E-8 SCREEN BUILDING DEMOLITION PLAN
E-9 DETRITOR BUILDING DEMOLITION PLAN
E-10 PUMP ROOM DEMOLITION PLAN
E-11 SCREEN BUILDING LIGHTING AND POWER PLAN
E-12 DETRITOR BUILDING LIGHTING AND POWER PLAN
E-13 PUMP ROOM LIGHTING AND POWER PLAN
E-14 BLOWER BUILDING POWER AND LIGHTING PLAN
E-15 ELECTRICAL BUILDING 1 POWER PLAN AND ONE LINE DIAGRAM MODIFICATIONS
E-16 BLOWER BUILDING GROUNDING PLAN
E-17 ELECTRICAL RISER DIAGRAMS AND SCHEMATIC DIAGRAMS
E-18 PANELBOARD AND LIGHTING FIXTURE SCHEDULES
E-19 ELECTRICAL STANDARD DETAILS I
E-20 ELECTRICAL STANDARD DETAILS II
ARUN MANDE
P R
O
FES S IO N A L ENGIN
E E
R
No. 12000142
RE G IS T ERED
STATE OF
I N D I A N A
C-1
CIVIL NOTES, LEGEND, AND ABBREVIATIONS
GARY SANITARY DISTRICT
GARY, INDIANA
SOLICITATION NUMBER W912P620B0020
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
563 South Lake Street, Suite 1A
Gary, Indiana 46403
EEE
WWW
EEE
ARUN MANDE
P R
O
FES S IO N A L ENGIN
E E
R
No. 12000142
REG IS T ERED
E E E E E E E
E
E
E
E
E
E
E E
E
E
E
TUNNEL TO PUMP ROOM
PUMP ROOM
DETRITOR
BUILDING
SCREEN
BUILDING
ELECTRICAL
BUILDING 1
CHICAGO SOUTH SHORE & SOUTH BEND RAILROAD
ELECTRICAL ROOM
TRASH RACK
GATE AREA
BLOWER BUILDING
NATURAL GAS
GENERATOR
G G
G G
G G
G G
G G
G G
G
G
G
G
G
G
G
G
W
W
W W W W W W W W W
W W
W W
W W
W
W
W
W
W
W
WWWWWWWWWWWWWWWWWWWWWW
W W
W
W
W
W
W
E
E
EE
E E
EE
E
TEST PIT (TYP OF 6)
EXISTING TRENWAY (TYP)
PERFORM SURFACE
RESTORATION FOR EXTERIOR
ELECTRICAL AND HVAC WORK
PERFORM SURFACE RESTORATION
FOR ELECTRICAL DUCTBANKS
PERFORM SURFACE RESTORATION
FOR EXTERIOR HVAC WORK
GARY SANITARY DISTRICT
GARY, INDIANA
SOLICITATION NUMBER W912P620B0020
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
563 South Lake Street, Suite 1A
Gary, Indiana 46403 C-2
SITE PLAN
N
PLAN
DETAIL A
ARUN MANDE
P R
O
FES S IO N A L ENGIN
E E
R
No. 12000142
RE G IS T ERED
AB
ABV
ACMU
AFF
AFG
AL, ALUM
AMP
ANOD
ASSY
BBT
BD
BEV
BLDG
BLK
BLKG
BRG
BRK
BRS
BRZ
BTM
C TO C
CAB
CEM
CF
CGFB
CH
CHAM
CHAN
CIP
CJ
CL OR
CLG
CLKG
CMU
COL
COMP
CONC
CONT
CRPT
CRS
CT
CET
DF
DIA
DIAG
DIM
DISP
DN
DP
DR
ELEC
ELEV
EQ
EQPT
EWC
EXP
EJ
EXIST, (E)
FD
FE
FF
FGL
FIN
FLG
FL
FLR
FR
FRP
FO
FV
FXD
GA
GALV
GL
AND
ANGLE
AT
ANCHOR BOLT
ABOVE
ACOUSTICAL CONCRETE MASONRY UNIT
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ALUMINUM
ACOUSTICAL METAL PANELS
ANODIZE(D)
ASSEMBLY
BIOBASED TILE
BOARD
BEVEL(ED)
BUILDING
BLOCK
BLOCKING
BEARING
BRICK
BRASS
BRONZE
BOTTOM
CENTER TO CENTER
CABINET
CEMENT
COMPRESSIBLE FILLER
CEMENTITIOUS GLASS FIBER BOARD
CONCRETE HARDENER
CHAMFER
CHANNEL
CAST IN PLACE
CONTROL JOINT
CENTERLINE
CEILING
CAULKING
CONCRETE MASONRY UNIT
COLUMN
COMPRESSIBLE
CONCRETE
CONTINUOUS
CARPET, CARPET TILE
COURSE(S)
CERAMIC TILE
DETAIL
DRINKING FOUNTAIN
DIAMETER
DIAGONAL
DIMENSION
DISPENSER
DOWN
DAMPPROOFING
DRAIN
ELECTRICAL
ELEVATION
EQUAL(LY)
EQUIPMENT
ELECTRICAL WATER COOLER
EXPOSED
EXPANSION JOINT
EXISTING
FLOOR DRAIN
FIRE EXTINGUISHER
FACTORY FINISH
FIBERGLASS
FINISH(ED)
FLASHING
FLOOR(ING)
FILLER
FRAME
FIBERGLASS REINFORCED PLASTIC
FRAME OPENING
FIELD VERIFY
FIXED
GAGE, GAUGE
GALVANIZED
GLASS
GB
GRT
GYP
GWB
HARD
HD
HDWD
HDWR
HGR
HGT
HM
HOR
HP
HR
IN
INST
INSUL
JC
JT
JT FLR
L
LAB
LAD
LAM
LAV
LG
LINO
LKR
LNTL
LP
LT
MAS
MATL
MAX
MEMB
MFR
MIN
MISC
MO
MR
MRAT
MTD
MTG
MTL
NIC
NOM
NTS
OC
OH
OPNG
OPP HD
ORD
OSB
OV
OVHD
PERIM
PL
PL
PLAS
PLK
PLYWD
PM
PR
PRD
PRCST
PREFAB
PT
PRMLD
PSF
PTD
QT
QTB
R R+S
RB
RD
RECT
GLASS BLOCK
GRATING
GYPSUM
GYPSUM WALL BOARD
HARDENER
HEAVY DUTY
HARDWOOD
HARDWARE
HANGER
HEIGHT
HOLLOW METAL
HORIZONTAL
HIGH POINT
HANDRAIL
INCH
INSTRUMENTATION
ISULATION
JANITOR'S CLOSET
JOINT
JOINT FILLER
LINE OF STRUCTURAL ANGLE DESIGNATION
LABORATORY
LADDER
LAMINIATED
LAVATORY
LAMINATED GLASS
LINOLEUM
LOCKER
LINTEL
LOW POINT
LIGHT(S)
MASONRY
MATERIAL
MAXIMUM
MEMBRANE
MANUFACTURER
MINIMUM
MISCELLANEOUS
MASONRY OPENING
MOISTURE RESISTANT
MOISTURE RESISTANT ACOUSTICAL TILE
MOUNTED
MOUNTING
METAL
NOT IN CONTRACT
MONINAL
NOT TO SCALE
ON CENTER
OVERHANG
OPENING
OPPOSITE HAND
OVERFLOW ROOF DRAIN
ORIENTED STRAND BOARD
OVER
OVERHEAD
PERIMETER
PLATE
PROPERTY LINE
PLASTER
PLANK
PLYWOOD
PRESSED METAL
PAIR
PROMENADE ROOF DRAIN
PRECAST
PRE-FABRICATED
PREASSURE TREATED
PREMOLDED
POUNDS PER SQUARE FOOT
PAINTED
QUARRY TILE
QUARRY TILE BASE
RISER(S)
BACKER ROD & SEALANT
RUBBER BASE
ROOF DRAIN
RECEPTACLE
REF
REINF
REQ'D
REV
RF
RFG
RGH
RJ
RL
RLG
RM
RO
RT
RWL
S
SAT
SB
SCHD
SCRN
SECT
SF
SGFT
SHT
SIM
SK
SL
SLNT
SPEC
SS
STD
STL
STOR
STRU
STWY
SUPT
SUSP
T
TBM
T&G
TEMP
TEMP
TEMP
TER
TERB
THK
THR
TKBD
TOB
TOC
TOIL
TOM
TOPG
TOS
TS
TSL
TWF
TYP
UC
UON
UR
VB
VCT
VERT
VEST
VTR
W W/ W/A W/O
WC
WD
WDW
WF
WPG
WT
WWF
ROOF EXHAUST FAN
REINFORCE (D, ING)
REQUIRED
REVISED
ROOF FAN
ROOFING
ROUGH
REVEAL/RUSTICATION JOINT
RAIN LEADER
RAILING
ROOM
ROUGH OPENING
RUBBER TILE
RAIN WATER LEADER
STEEL S-SHAPED DESIGNATION
SUSPENDED ACOUSTICAL TILE
SEAMLESS BASE
SCHEDULE
SCREEN(ED, ING)
SECTION
SEAMLESS FLOORING
STRUCTURAL GLAZED FACING TILE
SHEET
SIMILAR
SINK
SLOPE
SEALANT
SPECIFICATION, SPECIFIED
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STRUCTURE(S, URAL)
STAIRWAY
SUPERINTENDENT
SUSPENDED
TREAD(S)
TRAFFIC BEARING MEMBRANE
TONGUE AND GROOVE
TEMPERATURE
TEMPERED
TEMPORARY
TERRAZZO
TERRAZZO BASE
THICK(NESS)
THRESHOLD
TACKBOARD
TOP OF BRICK
TOP OF CONCRETE
TOILET
TOP OF MASONRY
TOPPING
TOP OF STEEL
STRUCTURAL TUBING (STEEL UNLESS NOTED)
TOP OF SLAB
THROUGH WALL FLASHING
TYPICAL
UNDERCUT
UNLESS OTHERWISE NOTED
URINAL
VAPOR BARRIER
VINYL COMPOSITE TILE
VERTICAL
VESTIBULE
VENT THRU ROOF
WITH
WITH
WHERE APPLICABLE
WITHOUT
WATER CLOSET
WOOD
WINDOW
WIDE FLANGE
WATERPROOFING
STEEL TEE-SHAPE DESIGNATION
WELDED WIRE FABRIC
1. HEIGHT OF INTERIOR STUD AND CMU PARTITIONS ARE FROM FLOOR TO THE UNDERSIDE
OF ROOF DECK UNLESS OTHERWISE NOTED. PROVIDE DEFLECTION HEADS AT TOP OF
WALL (TYPICAL).
2. NOT ALL EQUIPMENT IS SHOWN FOR CLARITY. REFER TO THE APPROPRIATE DISCIPLINE
SHEETS FOR SPECIFIC EQUIPMENT LAYOUT AND OTHER REQUIREMENTS
3. SEE CIVIL SHEETS FOR SIDEWALK, ROAD PAVING AND FINISH GRADE ELEVATIONS.
4. SEE STRUCTURAL SHEETS FOR SIZE AND LOCATION OF CONCRETE PADS, TRENCHES,
VAULTS, SUMPS, ETC
5. SEE STRUCTURAL SHEETS FOR CONCRETE AND MASONRY REINFORCEMENT
6. ALL INTERIOR CMU WALLS SHALL BE PROVIDED WITH INSULATION INSERTS (SEE SPEC
04200)
7. PATCH AND REPAIR ANY MATERIALS OR SURFACES DAMAGED DURING THE
CONSTRUCTION PROCESS TO MATCH THE EXISTING ADJACENT SURFACES.
8. ALL ITEMS TO BE NEW UNLESS SPECIFICALLY NOTED OTHERWISE.
9. ALL JOINTS, VOIDS AND PENETRATIONS THROUGH FIRE-RATED WALL SYSTEMS ARE TO BE
FILLED/SEALED WITH UL APPROVED FIRESAFING/FIRESTOPPING MATERIALS TO ACHIEVE
THE REQUIRED FIRE-RATING (REFER TO CODE DRAWINGS FOR LOCATIONS).
10. DO NOT SCALE FROM THE DRAWINGS
11. NOTIFY ARCHITECT IF CONSTRUCTION DOCUMENTS DIFFER FROM ACTUAL FIELD
CONDITIONS PRIOR TO FABRICATION OR NEW CONSTRUCTION
12. THIS DRAWING CONTAINS A GENERAL LIST OF SYMBOLS AND ABBREVIATIONS. NOT ALL
ITEMS SHOWN HERE APPEAR ON THE CONTRACT DRAWINGS.
DASHED ON CONSTRUCTION PLAN/SHEETS -
HIDDEN ELEMENTS BEYOND, ABOVE OR
BELOW
CONTINUOUS - NEW CONSTRUCTION
(UNLESS OTHERWISE NOTED)
CONCRETE MASONRY UNIT (CMU)
BRICK
EARTH
PRECAST CONCRETE
CAST-IN-PLACE CONCRETE
WOOD BLOCKING
WOOD FINISH
PLYWOOD
RIGID INSULATION
STEEL
ALUMINUM
STUCCO / GROUT
CAULK
GRAVEL
BLANKET INSULATION
A-2
A
COLUMN TAG AND &
CENTER LINE
TSL
501'-8"
FFE
501'-8"
SPOT ELEVATION
ELEVATION CALLOUT
LEVEL NAME
ELEVATION
PARTITION TYPE
SUFFIX A,B,C, ETC. W/A
SEE NOTE ON TYPE
DESCRIPTION
SUFFIX 1,2,3,4 IS FIRE
RESISTANCE RATING W/A NOTE: SEE WALL SECTIONS FOR
ADDITIONAL REQUIREMENTS
A-2
A-2
A-1
A-101
ROOM NAME
ROOM TAG
BUILDING DESIGNATION
(IF APPLICABLE)
ROOM NUMBER
001 SUB BASEMENT
01 BASEMENT
101 GROUND FL
201 SECOND FL
INTERIOR ELEVATION
SHEET NO.
ELEVATION NO.
A-2
BUILDING SECTION
INDICATOR
WALL SECTION
INDICATOR
DETAIL INDICATOR
IF SECTION OR DETAIL IS
DRAWN ON THE SAME SHEET
THAT IT IS TAKEN FROM, THE
SHEET NUMBER IS A HYPHEN. IF
THE SECTION IS REFERENCED
ON MULTIPLE SHEETS, THE
SHEET NUMBER SHOWN
INDICATES THE FIRST SHEET
THE SECTION IS TAKEN FROM.
FIRE EXTINGUISHER
FE-X
FE-1 SEMI-RECESSED
FE-2 WALL MOUNTED
FE-3 CARBON DIOXIDE
(WALL MOUNTED)
1 KEYNOTE CALLOUT
KEYNOTE DESIGNATION,
CORRESPONDS TO KEY
ON EACH SHEET
APPLICABLE CODES 2014 INDIANA BUILDING CODE, BUILDING
2014 INDIANA BUILDING CODE, FIRE PREVENTION
2014 INDIANA BUILDING CODE, ACCESSIBILITY
NATIONAL FIRE PROTECTION ASSOCIATIONS, NFPA 820
GARY SANITARY DISTRICT WASTEWATER TREATMENT PLANT KEY DETERMINATIONS (BLOWER BUILDING)
BUILDING CLASSIFICATION
OCCUPANCY - F-2 FACTORY-INDUSTRIAL (LOW-HAZARD)
CONSTRUCTION - TYPE II B
BUILDING HEIGHTS AND AREAS MAX AREA 23,000 SF PER FLOOR ACTUAL 8,555 SF (EXISTING)
TABLE 503*
MAX HEIGHT 55 FEET ACTUAL 42 FEET
MAX STORES 3 ACTUAL 2
REQUIRED SEPARATION STAIR 1 HOUR
TABLE 508.4 ELEVATOR 1 HOUR
ELEVATOR MECH ROOM 1 HOUR
ASSEMBLY 1 HOUR
ROOM SEPARATION ELECTRICAL 0 HOUR
FIRE SEPARATION DISTANCE TYPE II B > 30 FEET FROM BLDGS & PROPERTY LINE - 0 HR
FIRE RESISTANCE RATING ACTUAL = >30 FOOT SEPARATION 0 HR
STAIRS MIN WIDTH 44" CLEAR ACTUAL EXISTING
SECTION 1009
MIN RISER HEIGHT 7" ACTUAL EXISTING
MIN TREAD DEPTH 11" ACTUAL EXISTING
RAMPS N/A
ELECTRICAL ROOM 15 FEET SEPERATION ACTUAL **** FEET
SPRINKLERS REQUIRED NO PROVIDED: NO
FIRE ALARM REQUIRED NO PROVIDED: NO
EGRESS REQUIREMENTS (ELECTRICAL ROOM) MAX TRAVEL DISTANCE 300 FEET PROVIDED: 26 FEET
THE FOLLOWING ITEMS ARE TO BE PAINTED IN THE BLOWER BUILDING AND SCREEN BUILDING:
* ALL NEW STRUCTURAL STEEL IN SCREEN BUILDING
* ALL NEW CONCRETE
* ALL NEW CONCRETE MASONRY
* ALL NEW DOORS AND FRAMES IN BLOWER BUILDING
* ALL NEW PIPING (EXCEPT SS)
* EXISTING INSIDE CONCRETE WALLS AT SECOND FLOOR
* EXISTING GUARDRAILS ON SECOND FLOOR
* DO NOT PAINT EXISTING PIPING
* NEW STEEL DECK IN SCREEN BUILDING
ELECTRICAL ROOM
26'
F-2
BLOWER BUILDING
EGRESS PATH
TRAVEL DISTANCE
(FEET)
AREA OR SPACE EXIT
X
BLOWER BLDG PUMP ROOM
DETRITOR
BLDG
SCREEN
BLDG
ELECTRICAL ROOM ELECTRICAL
BLDG 1
ABBREVIATIONS
GENERAL NOTES
LINE TYPES
MATERIAL SYMBOLS
SYMBOLS
Building Code Key Determinations (Indiana Building Code)
PAINT SCHEDULE
A B C D E F
C
D M
S M
IT
H
A L
L R
IG
H
T S
R E
S E
R V
E D
R
E U
S E
O F
D O
C U
M E
N T
S T
H E
E S
E D
O C
U M
E N
T S
A N
D D
E S
IG
N
S P
R O
V
ID
E D
B Y
P R
O F
E S
S
IO
N A
L S
E R
V
IC
E
IN
C O
R P
O R
A T
E D
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F C
D M
S M
IT
H
A N
D A
R E
N O
T T
O B
E U
S E
R
IN
W H
O L
E O
R P
A R
T F
O R
A N
Y O
T H
E R
P R
O J E
C T
W
IT
H O
U T
T H
E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N
O F
C D
M S
M
IT
H
DATE:
APPROVED BY:
CROSS CHK'D BY:
SHEET CHK'D BY:
DRAWN BY:
DESIGNED BY:
JUNE 2020
563 South Lake Street, Suite 1A Gary, Indiana 46403
PROJECT NO.
FILE NAME:
SHEET NO.
REMARKSCHKDDRWNDATE
REV.
NO.
HG
GARY SANITARY DISTRICT
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
GARY, INDIANA
29021-228129
SOLICITATION NUMBER W912P620B0020
L. LOHMAN
H. ATKINS
L. LOHMAN
T. KING
L. LOHMAN
ABBREVIATIONS, NOTES,
CODE SUMMARY A-1
AWZ001GB.RVT
1/8" = 1'-0"
LIFE SAFETY PLAN
LIFE SAFETY LEGEND
SITE PLAN
NEW REMOVABLE SKYLIGHTS, TYP.
HP
NEW ROOF DRAIN
1/4"/1'-0"
1/4"/1'-0"
NEW ROOF DRAIN
90 MIL. EPDM ROOF OVER
TAPERED INSULATION ON
NEW ROOF DECK
NEW ALUMINUM
ROOF LADDER
NEW ALUMINUM COPING
A-2
A-2
A-2
NEW ROOF SCUPPER
NEW ROOF SCUPPER
A-2
9'-0" *
9'-6" *
9'-6" *
NOTE: * INDICATES DIMENSION TO BE COORDINATED WITH
APPROVED SKYLIGHT AND EQUIPMENT DRAWINGS.
ROOF DECK - FOR PAINT
NEW ALUMINUM COPING
CONCRETE PARAPET
ROOF MEMBRANE
LAP SEALANT
TAPERED INSULATION
SLOPE TO DRAIN
SEE STRUCTURAL
FOR REINFORCING
WOOD BLOCKING
FOR PAINT
1/2" PROTECTION BOARD
A D
D B
L O
C K
IN
G
A S
R E
Q
M
IN
PRESSURE TREATED BLOCKING
REMOVABLE TRANSLUCENT
FIBERGLASS SKYLIGHT
INSULATED GALVANIZED
CURB W/ CLOSURE PLATE
2X PRESSURE TREATED
WOOD BLOCKING
STL. BEAM W/ BENT STL.
CLOSURE PLATES AND METAL
DECKING
TAPERED INSULATION
SLOPE TO DRAIN
CURB FLASHING BY MFR.
FOR PAINT
WOOD BLOCKING
1/2" PROTECTION BOARD
ROOF FLASHING WITH
TERMINATION BAR
ALUMINUM CLOSURE TRIM
*SKYLIGHT MANUFACTURER MAY PROPOSE
ALTERNATE DETAIL IN LIEU OF ROOF DETAIL
REMOVABLE TRANSLUCENT
FIBERGLASS SKYLIGHT
TAPERED INSULATION
SLOPE TO DRAIN
STL. BEAM W/ BENT STL.
CLOSURE PLATES AND
METAL DECKING
2X PRESSURE TREATED
WOOD BLOCKING
INSULATED GALVANIZED
CURB W/ CLOSURE PLATE
WOOD BLOCKING
ROOF MEMBRANE
LAP SEALANT
CURB FLASHING BY MFR.
FOR PAINT
1/2" PROTECTION BOARD
ROOF FLASHING WITH
TERMINATION BAR
ALUMINUM CLOSURE TRIM
ROOF DECK -
FOR PAINT
TAPERED INSULATION
SLOPED TO DRAIN
NEW ALUMINUM COPING
CONCRETE PARAPET
ROOF MEMBRANE
CONT. SEALANT AROUND
ALUMINUM SCUPPER SLEEVE
CONT. WELDED
SCUPPER SLEEVE
FASTENER PER MFR.
BONDING ADHESIVE
WOOD BLOCKING
FOR PAINT
1/2" PROTECTION BOARD
PRESSURE TREATED BLOCKING
A B C D E F
C
D M
S M
IT
H
A L
L R
IG
H
T S
R E
S E
R V
E D
R
E U
S E
O F
D O
C U
M E
N T
S T
H E
E S
E D
O C
U M
E N
T S
A N
D D
E S
IG
N
S P
R O
V
ID
E D
B Y
P R
O F
E S
S
IO
N A
L S
E R
V
IC
E
IN
C O
R P
O R
A T
E D
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F C
D M
S M
IT
H
A N
D A
R E
N O
T T
O B
E U
S E
R
IN
W H
O L
E O
R P
A R
T F
O R
A N
Y O
T H
E R
P R
O J E
C T
W
IT
H O
U T
T H
E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N
O F
C D
M S
M
IT
H
DATE:
APPROVED BY:
CROSS CHK'D BY:
SHEET CHK'D BY:
DRAWN BY:
DESIGNED BY:
JUNE 2020
563 South Lake Street, Suite 1A Gary, Indiana 46403
PROJECT NO.
FILE NAME:
SHEET NO.
REMARKSCHKDDRWNDATE
REV.
NO.
HG
GARY SANITARY DISTRICT
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
GARY, INDIANA
29021-228129
SOLICITATION NUMBER W912P620B0020
L. LOHMAN
H. ATKINS
L. LOHMAN
T. KING
L. LOHMAN
SCREEN BUILDING
NEW ROOF PLAN AND DETAILS A-2
AWZ001GB.RVT
1/4" = 1'-0"
ROOF PLAN
_ 1 1/2" = 1'-0"
3 DETAIL 3
_ 1 1/2" = 1'-0"
2 DETAIL 2
_ 1 1/2" = 1'-0"
1 DETAIL 1
_ 1 1/2" = 1'-0"
4 DETAIL 4
NEW 8" STRUCTURAL
GLAZED TILE INFILL - 2 HR
RATED WALL
EXISTING MASONRY WALLS
HOLLOW METAL DOOR
HOLLOW METAL DOORS
ELECTRICAL ROOM
A-3
8" 3'-4" 7'-0"
DA-1 DA-3
1'-6" 11'-0" 6'-1" 11'-0" 6'-1" 11'-0" 1'-6"
48'-2"
4'-0" 6'-4" 8"
DA-2
NOTE: CONDUIT TRAYS TO HAVE 2-HOUR FIRE RATED ENCLOSURES
Level 1 591.10
ARCH BASEMENT
PLAN
582.20
NEW 8" STRUCTURAL
GLAZED TILE INFILL
EXISTING CEILING
EXISTING STRUCTURAL
GLAZED TILE
7 5/8"
STEEL ANGLE - SEE "S" DWGS FOR DETAILS
NEW 8" STRUCTURAL GLAZED TILE INFILL
SEALANT, BACKER ROD AND
SHIM AS NEEDED
REMOVABLE TRANSOM
PANEL
FRAME BEYOND
GROUT SOLID AT RATED DOORS
BOND BEAM
HOLLOW METAL
GROUT CELL
SOLID
FRAME ANCHOR
(3 PER JAMB)
SEALANT, BACKER ROD AND
SHIM AS NEEDED
NEW 8" STRUCTURAL
GLAZED TILE INFILL
HOLLOW METAL DOOR AND FRAME.
FOR PAINT.
THRESHOLD SET IN MASTIC
EXISTING TILE
F3
S E
E S
C H
E D
U L E
2"
SCHEDULE
SEE 2"
REMOVABLE TRANSOM
RATED HOLLOW METAL
PANEL
F
S E
E S
C H
E D
U L
E
FLUSH
DOOR HARDWARE SET #1:
HINGES
2- EXIT DEVICE- EXPOSED VERTICAL RODS
2- CLOSERS
2- KICK PLATES
PERIMETER SEALS
DOOR HARDWARE SET #2:
HINGES
1- EXIT DEVICE- EXPOSED VERTICAL RODS
1- CLOSERS
1- KICK PLATES
PERIMETER SEALS
A B C D E F
C
D M
S M
IT
H
A L
L R
IG
H
T S
R E
S E
R V
E D
R
E U
S E
O F
D O
C U
M E
N T
S T
H E
E S
E D
O C
U M
E N
T S
A N
D D
E S
IG
N
S P
R O
V
ID
E D
B Y
P R
O F
E S
S
IO
N A
L S
E R
V
IC
E
IN
C O
R P
O R
A T
E D
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F C
D M
S M
IT
H
A N
D A
R E
N O
T T
O B
E U
S E
R
IN
W H
O L
E O
R P
A R
T F
O R
A N
Y O
T H
E R
P R
O J E
C T
W
IT
H O
U T
T H
E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N
O F
C D
M S
M
IT
H
DATE:
APPROVED BY:
CROSS CHK'D BY:
SHEET CHK'D BY:
DRAWN BY:
DESIGNED BY:
JUNE 2020
563 South Lake Street, Suite 1A Gary, Indiana 46403
PROJECT NO.
FILE NAME:
SHEET NO.
REMARKSCHKDDRWNDATE
REV.
NO.
HG
GARY SANITARY DISTRICT
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
GARY, INDIANA
29021-228129
SOLICITATION NUMBER W912P620B0020
L. LOHMAN
H. ATKINS
L. LOHMAN
T. KING
L. LOHMAN
BLOWER BUILDING
PLAN AND DETAILS A-3
AWZ001GB.RVT
1/4" = 1'-0"
ELECTRICAL ROOM PLAN
_ 1/2" = 1'-0"
1 2 HR FIRE RATED WALL SECTION
DOOR SCHEDULE
DOOR
NUMBER PAIR
SIZE DOOR FRAME FIRE
RATING
(MIN)
HARDWARE
SETWIDTH HEIGHT TYPE MATERIAL FINISH TYPE MATERIAL FINISH
DA-1 NO 3'-0" 7'-2" F HM PT F3 HM PT 90 MIN 2
DA-2 YES 3'-0" 7'-2" F HM PT F3 HM PT 90 MIN 1
DA-3 YES 3'-0" 7'-2" F HM PT F3 HM PT 90 MIN 1
_ 1 1/2" = 1'-0"
2 HEAD DETAIL
_ 1 1/2" = 1'-0"
3 JAMB DETAIL
_ 1 1/2" = 1'-0"
4 THRESHOLD
DOOR FRAMESDOOR TYPES
DOOR HARDWARE SETS
A. GENERAL NOTES
1.
2.
3.
4.
5.
ALL STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE OTHER PROJECT
DRAWINGS AND SPECIFICATIONS.
SEE CIVIL, ELECTRICAL, ARCHITECTURAL, MECHANICAL, HEATING AND VENTILATING, AND
PLUMBING DRAWINGS FOR ANCHORS, PIPE SLEEVES, CONDUITS OR OTHER ITEMS TO BE
EMBEDDED OR PASSED THROUGH THE CONCRETE.
SEE CIVIL SITE PLANS FOR STRUCTURE LOCATION COORDINATES AND GRADING PLAN FOR
FINISHED GRADE ELEVATIONS.
THE CONTRACTOR SHALL REVIEW AND VERIFY DIMENSIONS SHOWN IN ALL DRAWINGS AND
REVIEW ALL FIELD CONDITIONS THAT MAY AFFECT THE INSTALLATION OF THE STRUCTURES.
SHOULD DISCREPANCIES APPEAR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN
WRITING TO OBTAIN ENGINEER'S CLARIFICATION BEFORE COMMENCING THE WORK.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR STRUCTURAL STABILITY DURING
CONSTRUCTION. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR
STABILITY UNDER THE FINAL CONFIGURATION ONLY.
B. DESIGN CRITERIA
1. CODES:
a. 2012 INTERNATIONAL BUILDING CODE, ASCE 7-10
b. ACI 318-11, ACI 360-10
2. FLOOR LIVE LOADS:
ROOF AREA = 20 PSF; OR CONCENTRATED EQUIPMENT LOAD
PROCESS AREA = 200 PSF OR CONCENTRATED EQUIPMENT LOAD + 50 PSF
ELECTRICAL ROOM = 300 PSF OR CONCENTRATED EQUIPMENT LOAD
3. SNOW LOADS:
GROUND SNOW LOAD = 30 PSF
Ct=1.0 Ce=1.0 Is=1.0
4. WIND LOADS:
OCCUPANCY CATEGORY II
BASIC WIND SPEED = 115 MPH (3-SEC GUST)
EXPOSURE CATEGORY = B
5. SEISMIC LOADS
OCCUPANCY CATEGORY II
SEISMIC DESIGN CATEGORY = B
SS=0.127 S1=0.063
Fa=1.6 Fv=2.4
SDS=.0135 SD1=0.102
C. CAST-IN-PLACE CONCRETE NOTES
1.
2.
3.
4.
5.
6.
7.
8.
REINFORCED CONCRETE SHALL CONFORM TO ACI 318-08.
MINIMUM CONCRETE STRENGTH AT 28 DAYS:
CONCRETE FILL (PIPE & DUCT ENCASEMENT, ETC) ......................................................... f'c = 2,500 PSI STRUCTURAL CONCRETE (FOUNDATION, WALL, SLAB, BEAM, EQUIPMENT PADS ETC)..f'c = 4,000 PSI
REINFORCING STEEL SHALL BE BILLET STEEL CONFORMING TO THE LATEST EDITION OF ASTM A-615 GRADE 60.
REINFORCING STEEL FABRICATION SHALL BE IN COMPLIANCE WITH THE LATEST EDITION OF THE CRSI MANUAL
OF STANDARD PRACTICE.
REINFORCING STEEL SHALL HAVE THE FOLLOWING MINIMUM CLEAR CONCRETE COVER UNO:
a. CONCRETE CAST EARTH (BOTTOM OF SLABS, FOOTINGS): .................................................. 3"
b. CONCRETE SURFACES EXPOSED TO EARTH OR WEATHER: ................................................ 2"
c. CONCRETE SURFACES NOT EXPOSED TO EARTH OR WEATHER: ....................................... 1 1/2"
MINIMUM TENSION LAP SPLICE LENGTHS AND TENSION DEVELOPMENT LENGTHS FOR GRADE 60 REINFORCING BARS IN WALLS AND SLABS SHALL BE IN ACCORDANCE WITH TABLE BELOW, UNLESS OTHERWISE SHOWN ON THE DRAWINGS. LAP SPLICES AND DEVELOPMENT LENGTHS FOR WHICH DETAIL IS NOT APPLICABLE SHALL BE AS
SHOWN ON THE DRAWINGS.
ALL EXPOSED CORNERS OF CONCRETE TO HAVE 3/4" MINIMUM CHAMFER, UNO.
SIZE AND LOCATION OF EQUIPMENT PADS AND ANCHOR BOLTS SHALL BE AS REQUIRED BY THE EQUIPMENT
MANUFACTURER.
D. STEEL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ALL STRUCTURAL STEEL SHALL BE FABRICATED, ERECTED AND CONNECTED IN COMPLIANCE WITH THE
AISC MANUAL OF STEEL CONSTRUCTION 13TH EDITION.
MATERIALS:
a. WIDE FLANGES AND SPLIT TEES SHALL CONFORM TO ASTM A992 Fy = 50 KSI.
b. ALL OTHER STRUCTURAL SHAPES, PLATES AND BARS SHALL CONFORM TO ASTM A36.
c. HOLLOW STRUCTURAL SHAPES (HSS) SHALL CONFORM TO ASTM A500 GRADE B Fy=46 KSI.
STANDARD FRAMED BEAM CONNECTIONS SHALL BE DESIGNED (UNLESS DESIGN LOADS OR DETAILS ARE SHOWN IN THE PLANS) FOR ONE-HALF THE TOTAL ALLOWABLE UNIFORM LOAD CAPACITY FOR A GIVEN MEMBER AND SPAN AS INDICATED IN THE "ALLOWABLE LOADS ON BEAMS" TABLES OF THE AISC MANUAL OF STEEL CONSTRUCTION. THICKNESS OF CLIP ANGLES SHALL BE 3/8". MINIMUM GUSSET
PLATE THICKNESS IS 3/8".
ALL BOLTED MADE USING ASTM A 325 HIGH-STRENGTH BOLTS AS SHOWN ON THE DRAWINGS OR AS
SPECIFIED. ALL BOLTS SHALL BE 3/4"∅ IN 13/16"∅ HOLES UNLESS OTHERWISE SPECIFIED. ALL BOLTED CONNECTIONS SHALL HAVE 2 BOLTS MINIMUM, UNO AND SHALL BE BEARING TYPE WITH THREADS
INCLUDED IN SHEAR PLANE.
ALL CONNECTIONS SHALL BE SHOP WELDED - FIELD BOLTED TYPE, UNLESS OTHERWISE NOTED ON
THE DESIGN DRAWINGS.
ALL WELDING SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE STRUCTURAL WELDING CODE, AWS D1.1. WELD FILLER METAL SHALL BE AWS A5.1 OR A5.5 E70XX LOW HYDROGEN ELECTRODES, UNLESS OTHERWISE SPECIFIED. MINIMUM WELD SIZE SHALL BE 3/16 INCH FILLET WELD, UNLESS OTHERWISE NOTED. SURFACES TO BE WELDED SHALL BE WIRE BRUSHED CLEAN SURFACE BEFORE WELDING. WELDERS SHALL BE AWS CERTIFIED. SUBMIT COPY OF ALL CERTIFICATIONS TO THE
ENGINEER.
ALL STRUCTURAL STEEL SHALL BE PRIMED IN ACCORDANCE WITH SPECIFICATION 09 90 10 AND PAINTED IN ACCORDANCE WITH SPECIFICATION 09 91 00, EXCEPT STEEL EXPOSED TO WEATHER, DOOR/WINDOW LINTELS, SHELF ANGLES AND STEEL SO NOTED ON DRAWINGS TO BE HOT-DIP
GALVANIZED.
ALL STRUCTURAL STAINLESS STEEL SHAPES SHALL BE ASTM A276, TYPE 316 AND STAINLESS STEEL PLATE SHALL BE ASTM A240, TYPE 316L, (FOR WELDED COMPONENTS) UNLESS OTHERWISE NOTED.
ANCHOR BOLTS SHALL BE ASTM F1554 GRADE 36 WITH THREADS AT TOP AND BOTTOM FOR NUT AND WASHER, UNO. EACH ANCHOR BOLT SHALL HAVE ONE HEAVY HEX NUT AND ONE GRADE A WASHER, TOP AND BOTTOM UNO.
ADHESIVE ANCHORS SHALL BE HILTI HIT HY-200 WITH GALVANIZED RODS.
AB
ABV
ACC
ADDL
ALUM/AL
ALT
APPROX
B TO B
BEV
BLK
BOT
BRG
B/W
CIRC
CJ
CL
CLJ
CLR
CMU
COL
CONC
CONN
CONT
CPLG
CRS
CSK
CTR
d
DET
DIA
DIAG
DIR
DL
DO.
DWG
DWL
EA
EB
EF
EL
EMBED
EQ
EQUIP
ES
EW
EXIST
EXP JT
EXT
f'c f'm
FAB
FDN
FF
FHMS
FHWS
FL
FRP
FTG
GALV
GBT
GLB
GR
GRTG
H
HAS.
HDR
HOR
HP
ID
I.E.
IF.
NUMBER
AND
AT
ANCHOR BOLT
ABOVE
ACCELERATION
ADDITIONAL
ALUMINUM
ALTERNATE (ING)
APPROXIMATELY
BACK TO BACK
BEVEL (ED)
BLOCKING
BOTTOM
BEARING
BETWEEN
CIRCUMFERENTIAL
CONSTRUCTION JOINT
CENTERLINE
CONTROL JOINT
CLEAR
CONCRETE MASONRY UNITS
COLUMN
CONCRETE
CONNECTION
CONTINUOUS
COUPLING
COURSE (S)
COUNTERSINK
CENTER(ED)
PENNY
DETAIL
DIAMETER
DIAGONAL
DIRECTION
DEAD LOAD
DITTO
DRAWING
DOWEL
EACH
EXPANSION BOLT
EACH FACE
ELEVATION
EMBEDMENT
EQUAL (LY)
EQUIPMENT
EACH SIDE
EACH WAY
EXISTING
EXPANSION JOINT
EXTERIOR
CONCRETE COMPRESSION STRESS
MASONRY PRISM STRESS
FABRICATE (OR, ED)
FOUNDATION
FAR FACE
FLATHEAD MACHINE SCREW
FLATHEAD WOOD SCREW
FLOOR
FIBERGLASS REINFORCED PLASTIC
FOOTING
GALVANIZED
GRAVITY BELT THICKENER
GLASS BLOCK
GRADE
GRATING
HIGH
HEADED ANCHOR STUD
HEADER
HORIZONTAL
HIGH POINT
INSIDE
INVERT ELEVATION
INSIDE FACE
INT
INV
JT
KO
LG
LLH
LLV
LNTL
LOC(S)
LONG.
LP
LT
LW
MAS
MAX
MB
MCJ
MFR
MIN
MO
NF
NSG
NTS
OC
OD
OF.
OPNG
OPP
OPT
PCJ
PJF
PLYWD
PREFAB
PROJ
PVMT
R
RAD
RC
REF
REINF
REQD
REV
RLG
RO
RT
SCJ
SECT
SIM
SP
SQ
SS
STD
STIF
STIR
STL
SYM
T T/ T&B
TF
THD
TOC
TRNSV
TYP
UNO
VB
VIF
W W/ W/O
WD
WP
WSTP
WWF
INTERIOR
INVERT
JOINT
KNOCKOUT
LENGTH
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LINTEL
LOCATION(S)/LOCATED
LONGITUDINAL
LOW POINT
LEFT
LIGHTWEIGHT
MASONRY
MAXIMUM
MACHINE BOLTS
MASONRY CONTROL JOINT
MANUFACTURER
MINIMUM
MASONRY OPENING
NEAR FACE
NON-SHRINK GROUT
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OUTSIDE FACE
OPENING
OPPOSITE
OPTIONAL
PARTIAL CONTRACTION JOINT
PREMOLDED JOINT FILLER
PLYWOOD
PREFABRICATED
PROJECTION
PAVEMENT
RISER(S)
RADIUS
REINFORCED CONCRETE
REFERENCE/REFER
REINFORCE (D, ING)
REQUIRED
REVISION
RAILING
ROUGH OPENING
RIGHT
SLAB CONTROL JOINT
SECTION
SIMILAR
SPACE (S, ED)
SQUARE
STAINLESS STEEL
STANDARD
STIFFENER
STIRRUP (S)
STEEL
SYMMETRICAL
TREAD(S)
TOP OF
TOP AND BOTTOM
TOP FACE
THREADED
TOP OF CONCRETE
TRANSVERSE
TYPICAL
UNLESS NOTED OTHERWISE
VAPOR BARRIER
VERIFY IN FIELD
WIDE
WITH
WITHOUT
DRIFT WIDTH
WORKING POINT
WATERSTOP
WELDED WIRE FABRIC
ABBREVIATION NOTES:
1. ABBREVIATIONS AND DESIGNATIONS FOR STEEL MEMBERS MAY BE FOUND IN THE CURRENT MANUAL OF
STEEL CONSTRUCTION BY AISC.
2. ABBREVIATIONS OF TECHNICAL SOCIETIES AND TRADE ASSOCIATIONS MAY BE FOUND IN THE
SPECIFICATIONS.
3. WELDING SYMBOLS AND ABBREVIATIONS MAY BE FOUND IN AWS 2.4.
GRATING
SPAN
DIRECTION
EARTH FILL
UNDISTURBED
EARTH
CONCRETE
STRUCTURAL
FILL GRATING
CHECKERED
PLATE
GROUT
CONCRETE
MASONRY
INDICATES EQUIPMENT
PAD. COORDINATE SIZE W/
EQUIP REQUIREMENTS.1
S-2
A
S-2
SECTION DETAIL
A-2
TITLE
1/4" = 1'-0"
SECTION NUMBER
OR DETAIL LETTER
SHEET SECTION OR DETAIL
IS REFERENCED FROM
SECTION NUMBER
SHEET SECTION
IS LOCATED ON
DETAIL LETTER
SHEET DETAIL
IS LOCATED ON
SECTION OR DETAIL TITLE
SECTION AND DETAIL NOTES:
1. WHEN A SECTION OR DETAIL IS ON THE SAME SHEET FROM WHICH
IT IS TAKEN, THE SHEET NUMBER IS REPLACED WITH A HYPHEN.
2. WHEN A SECTION OR DETAIL IS REFERENCED IN A NOTE, THE
CALLOUT IS FORMATTED AS A/S-2.
W
ENDELL YANG
P R
O F
E
S S IO NA L ENG
IN
E
E R
No. 10808959
R
EG IS T ERED
STATE OF
I N D I A N A
A B C D E F
C
D M
S M
IT
H
A L
L R
IG
H
T S
R E
S E
R V
E D
R
E U
S E
O F
D O
C U
M E
N T
S T
H E
E S
E D
O C
U M
E N
T S
A N
D D
E S
IG
N
S P
R O
V
ID
E D
B Y
P R
O F
E S
S
IO
N A
L S
E R
V
IC
E
IN
C O
R P
O R
A T
E D
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F C
D M
S M
IT
H
A N
D A
R E
N O
T T
O B
E U
S E
R
IN
W H
O L
E O
R P
A R
T F
O R
A N
Y O
T H
E R
P R
O J E
C T
W
IT
H O
U T
T H
E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N
O F
C D
M S
M
IT
H
DATE:
APPROVED BY:
CROSS CHK'D BY:
SHEET CHK'D BY:
DRAWN BY:
DESIGNED BY:
JUNE 2020
563 South Lake Street, Suite 1A Gary, Indiana 46403
PROJECT NO.
FILE NAME:
SHEET NO.
REMARKSCHKDDRWNDATE
REV.
NO.
HG
GARY SANITARY DISTRICT
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
GARY, INDIANA
29021-228129
SOLICITATION NUMBER W912P620B0020
06/26/2020
B. CUNNINGHAM
B. CUNNINGHAM
W. YANG
L. SMITH-HORN
W. YANG
STRUCTURAL
GENERAL NOTES S-1
SEZ001GR.rvt
STRUCTURAL NOTES
STRUCTURAL LEGEND & SYMBOLS
STRUCTURAL ABBREVIATIONS
LEGEND
9 70 54
8 62 47
7 54 42
6 46 36
5 31 24
4 25 19
3 18 14
BAR SIZE TOP BARS OTHER BARS
f'c=4000 PSI
TENSION DEVELOPMENT LENGTHS
IN WALL AND SLABS (INCHES)
9 91 70
8 80 62
7 70 54
6 48 46
5 40 31
4 32 25
3 24 18
BAR SIZE TOP BARS OTHER BARS
f'c=4000 PSI
CLASS B TENSION LAP SPLICE LENGTHS
IN WALLS AND SLABS (INCHES)
NOTES:
a. MINIMUM BAR SPACING = 6" OC
b. MINIMUM CONCRETE COVER = 1"
c. A HORIZONTAL BAR IS CONSIDERED A TOP BAR IF NORE THAN
12" OF FRESH CONCRETE IS CAST DIRECTLY BELOW THE BAR
DEMOLISH EXISTING CMU WALL (TYP)
DEMOLISH EXISTING CONC CURB
DEMOLISH EXISTING CONC
PEDESTALS (TYP OF 8)
E X
IS
T
W X
T
O B
E D
E M
O L
IS
H E
D
E X
IS
T
W X
T
O B
E D
E M
O L
IS
H E
D
EXIST 10K1 TO BE DEMOLISHED
EXIST 10K1 TO BE DEMOLISHED
EXIST 10K1 TO BE DEMOLISHED
EXIST 10K1 TO BE DEMOLISHED
EXIST 10K1 TO BE DEMOLISHED
EXIST 10K1 TO BE DEMOLISHED
EXIST 12K1 TO BE DEMOLISHED
EXIST 10K1 TO BE DEMOLISHED
EXIST 10K1 TO BE DEMOLISHED
E X
IS
T
K
T
O B
E D
E M
O L
IS
H E
D
E X
IS
T
K
T
O B
E D
E M
O L
IS
H E
D
E X
IS
T
K
T
O B
E D
E M
O L
IS
H E
D
E X
IS
T
K
T
O B
E D
E M
O L
IS
H E
D
E X
IS
T
K
T
O B
E D
E M
O L
IS
H E
D
E X
IS
T
K
T
O B
E D
E M
O L
IS
H E
D
48' - 1"
EXISTING METAL DECK
TO BE DEMOLISHED
(TYP)
W
ENDELL YANG
P R
O F
E
S S IO NA L ENG
IN
E
E R
No. 10808959
R
EG IS T ERED
STATE OF
I N D I A N A
A B C D E F
C
D M
S M
IT
H
A L
L R
IG
H
T S
R E
S E
R V
E D
R
E U
S E
O F
D O
C U
M E
N T
S T
H E
E S
E D
O C
U M
E N
T S
A N
D D
E S
IG
N
S P
R O
V
ID
E D
B Y
P R
O F
E S
S
IO
N A
L S
E R
V
IC
E
IN
C O
R P
O R
A T
E D
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F C
D M
S M
IT
H
A N
D A
R E
N O
T T
O B
E U
S E
R
IN
W H
O L
E O
R P
A R
T F
O R
A N
Y O
T H
E R
P R
O J E
C T
W
IT
H O
U T
T H
E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N
O F
C D
M S
M
IT
H
DATE:
APPROVED BY:
CROSS CHK'D BY:
SHEET CHK'D BY:
DRAWN BY:
DESIGNED BY:
JUNE 2020
563 South Lake Street, Suite 1A Gary, Indiana 46403
PROJECT NO.
FILE NAME:
SHEET NO.
REMARKSCHKDDRWNDATE
REV.
NO.
HG
GARY SANITARY DISTRICT
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
GARY, INDIANA
29021-228129
SOLICITATION NUMBER W912P620B0020
06/26/2020
B. CUNNINGHAM
B. CUNNINGHAM
W. YANG
L. SMITH-HORN
W. YANG
SCREEN BUILDING STRUCTURAL
DEMOLITION PLAN S-2
SEZ001GR.rvt
1/4" = 1'-0"
PLAN
1/4" = 1'-0"
PLAN
TOC EL 34.18 VIF EXISTING ROOF FRAMING
S-5
W X
(N
E W
N
AL LADDER
12'-0"
4' - 6" * 10' - 3" * 4' - 6" *
5" SLAB
(NEW)
S-5
6' - 0" 6' - 0"
L4x4x3/8 GALV (4 SIDES)
B
S-5
S-57
S-5
W8X18(NEW) W8X18(NEW)
S E
E N
O T
E
FIELD LOCATE W8 AT
EQUIPMENT SUPPORT LEG
BELOW HOPPER (TYP)
18"* DIAMETER
OPENING (TYP OF 2)
8' - 2" 9' - 0" 9' - 6" 3' - 10" 9' - 2" 8' - 4"
1' - 0" 1' - 0"
48' - 1"
NEW 12"
CONC WALL
S-5
S-5
S-5
S-5
8' - 0" *
8' - 6" * 4' - 6" 8' - 6" *
1' - 4"
W X
W X
W X
W X
W X
W8X18
W8X18
W8X18
W8X18
W8X18
W8X18
W8X18
W8X18
W8X18
W8X18
W8X18
W8X18
W8X18 W8X18 W8X18 W8X18 W8X18
W8X18 W8X18 W8X18 W8X18 W8X18
W8X18 W8X18 W8X18
W8X18 W8X18 W8X18
W8X18
W8X18 W8X18
W8X18 W8X18 W8X18
W8X18 W8X18W8X18
W8X18
N
L4x4x3/8 GALV
(4 SIDES)
S-5
/2
D E
C K
(T
Y P
W
ENDELL YANG
P R
O F
E
S S IO NA L ENG
IN
E
E R
No. 10808959
R
EG IS T ERED
STATE OF
I N D I A N A
A B C D E F
C
D M
S M
IT
H
A L
L R
IG
H
T S
R E
S E
R V
E D
R
E U
S E
O F
D O
C U
M E
N T
S T
H E
E S
E D
O C
U M
E N
T S
A N
D D
E S
IG
N
S P
R O
V
ID
E D
B Y
P R
O F
E S
S
IO
N A
L S
E R
V
IC
E
IN
C O
R P
O R
A T
E D
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F C
D M
S M
IT
H
A N
D A
R E
N O
T T
O B
E U
S E
R
IN
W H
O L
E O
R P
A R
T F
O R
A N
Y O
T H
E R
P R
O J E
C T
W
IT
H O
U T
T H
E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N
O F
C D
M S
M
IT
H
DATE:
APPROVED BY:
CROSS CHK'D BY:
SHEET CHK'D BY:
DRAWN BY:
DESIGNED BY:
JUNE 2020
563 South Lake Street, Suite 1A Gary, Indiana 46403
PROJECT NO.
FILE NAME:
SHEET NO.
REMARKSCHKDDRWNDATE
REV.
NO.
HG
GARY SANITARY DISTRICT
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
GARY, INDIANA
29021-228129
SOLICITATION NUMBER W912P620B0020
06/26/2020
B. CUNNINGHAM
B. CUNNINGHAM
W. YANG
L. SMITH-HORN
W. YANG
SCREEN BUILDING STRUCTURAL
NEW WORK PLAN S-3
SEZ001GR.rvt
1/4" = 1'-0"
PLAN
1/4" = 1'-0"
PLAN
NOTES:
1. * INDICATES DIMENSION TO BE COORDINATED WITH
APPROVED SKYLIGHT AND EQUIPMENT DRAWINGS.
2. INDICATES EQUIPMENT PAD. FINAL PAD SIZE AND
LOCATION TO BE COORDINATED WITH APPROVED
EQUIPMENT DRAWINGS.
3. METAL ROOF AND FLOOR DECKS SHALL BE AS FOLLOWS.
A. 1 1/2" ROOF DECK SHALL BE VULCRAFT GALVANIZED
1.5B20 OR EQUAL.
B. 2" COMPOSITE DECK SHALL BE VULCRAFT
GALVANIZED 3VLI18 OR EQUAL.
SEE BELOW TABLE FOR DIAPHRAGM CONNECTION.
(TOC EL 34.18 VIF)
ROOF NEW WORK
(T/STL EL 51.83)
EXISTING FLOOR PLAN
DECK TYPE CONNECTION PATTERN EDGE CONNECTION SIDELAP CONNECTION
1.5B20 5/8 PUDDLE WELD 36/4 5/8 PUDDLE WELD @12 5/8 PUDDLE WELD @12
2VLI18 5/8 PUDDLE WELD 36/4 5/8 PUDDLE WELD @12 5/8 PUDDLE WELD @12
4. PRIOR TO CORING CONCRETE, SCAN SLAB OR WALL USING RADAR
TO LOCATE REBAR AND/OR CONDUIT AND WIRING ON TOP AND
BOTTOM SURFACES. LOCATE CORES AS TO AVOID REBAR AND/OR
CONDUITS. NOTIFY ENGINEER IMMEDIATELY UPON BECOMING AWARE
OF DISCREPANCIES WITHING AREA OF WORK
5.FIELD LOCATE W8 AT EQUIPMENT SUPPORT LEG BELOW HOPPER
(TYP)
2' - 2" *
2' - 2" *
N
S-4
EXISTING CONC CURB
TO BE DEMOLISHED
N
#4@12 EW T&B
#4@12 HILTI HY 200 EPOXY
DWLS 4" EMBED (4 SIDES)
EXIST CONC SLAB
NEW 8" CMU WALL
(TYP 3 LOCATIONS)
S-4
N
EXIST CONC SLAB
EXIST CONC WALL
S-4
A
#4@48 (GROUT CELLS W/ VERTICAL BARS)
#4@48 ADHESIVE DOWELS 4" EMBED
1/2" DIA THROUGH
BOLT @ 12
1/2" DIA HILTI KWIK
BOLT TZ OR EQUAL
L4x4x3/8 4" LONG@12
W
ENDELL YANG
P R
O F
E
S S IO NA L ENG
IN
E
E R
No. 10808959
R
EG IS T ERED
STATE OF
I N D I A N A
A B C D E F
C
D M
S M
IT
H
A L
L R
IG
H
T S
R E
S E
R V
E D
R
E U
S E
O F
D O
C U
M E
N T
S T
H E
E S
E D
O C
U M
E N
T S
A N
D D
E S
IG
N
S P
R O
V
ID
E D
B Y
P R
O F
E S
S
IO
N A
L S
E R
V
IC
E
IN
C O
R P
O R
A T
E D
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F C
D M
S M
IT
H
A N
D A
R E
N O
T T
O B
E U
S E
R
IN
W H
O L
E O
R P
A R
T F
O R
A N
Y O
T H
E R
P R
O J E
C T
W
IT
H O
U T
T H
E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N
O F
C D
M S
M
IT
H
DATE:
APPROVED BY:
CROSS CHK'D BY:
SHEET CHK'D BY:
DRAWN BY:
DESIGNED BY:
JUNE 2020
563 South Lake Street, Suite 1A Gary, Indiana 46403
PROJECT NO.
FILE NAME:
SHEET NO.
REMARKSCHKDDRWNDATE
REV.
NO.
HG
GARY SANITARY DISTRICT
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
GARY, INDIANA
29021-228129
SOLICITATION NUMBER W912P620B0020
06/26/2020
B. CUNNINGHAM
B. CUNNINGHAM
W. YANG
L. SMITH-HORN
W. YANG
DETRITOR BUILDING & ELECTRICAL ROOM
STRUCTURAL DEMOLITION AND NEW WORK PLANS S-4
SEZ001GR
1/4" = 1'-0"
PLAN
NOTES:
1. * INDICATES DIMENSION TO BE COORDINATED WITH
APPROVED EQUIPMENT DRAWINGS.
2. INDICATES EQUIPMENT PAD. FINAL PAD DIMENSIONS TO
BE COORDINATED WITH APPROVED EQUIPMENT.
1/4" = 1'-0"
PLAN
DEMO
NEW WORK
_ 1" = 1'-0"
1 SECTION
1/4" = 1'-0"
PLAN
ELECTRICAL ROOM
_ 1/2" = 1'-0"
2 SECTION
_ 1" = 1'-0"
A DETAIL
(T/CONC EL -15.33 VIF)
(T/CONC EL -15.33 VIF)
(T/CONC EL 3.00 VIF)
24"x12" BEAM POCKET
(2)-3/4" DIA HILTI HIT-HY 200
ANCHOR BOLT 6" EMBED
8"
NSG
1 1/2" METAL ROOF DECK
N S
G
T/STL EL 51.83
#4@12 EW EF
W21
EX CONC WALL
1' - 0"
T/ WALL EL 53.75
T/EXIST WALL EL 50.00 VIF
#4 HILTI HIT-HY 200
EPOXY DWLS@12 6"
EMBED
#4@12 HILTI HIT-HY 200 DWLS
W/ 6" EMBED EF
1 1/2" METAL ROOF DECK
#4@12 EW
T/WALL EL 53.75
EX CONC WALL
1' - 0"
3" 6" 3"
T/EXIST WALL EL 50.00 VIF
1/2" DIA HILTI HIT-HY 200
EPOXY BOLTS 4" EMBED @
12 OC
NEW CONCRETE
(2)-3/4" DIA HILTI HIT-HY 200
ANCHOR BOLTS ON 5 1/2"
GAGE 6" EMBED
W8
T/STL EL 51.83
EX CONC WALL
1' - 0"
T/WALL EL 53.75
EL 50.00 VIF
L4x4x3/8 8" LONG GALV
HORIZONTAL
SLOT IN L5x3
6x6 - W1.4xW1.4 WELDED
WIRE FABRIC
EX CONC
BEAM BEYOND
S-5
A
EX CONC
BEAM
TOC EL 34.18 VIF
2" 18 GAUGE COMPOSITE
METAL DECK W/ 3" CONC
SLAB (5" TOTAL)
W8
L4x4x3/8 (4 SIDES)
1/2" DIA HILTI HIT-HY 200 EPOXY
BOLTS 4" EMBED @8 OC
EXIST CONC BEAM
#4@12 EW T&B
#4@12
(2)-#4 BARS
1' - 0" 1' - 0"
NOTE:
1. * INDICATES DIMENSION TO BE
COORDINATED WITH APPROVED
EQUIPMENT DRAWING
2. SEE SPEC 31 00 00 FOR SUBGRADE
PREPARATION
WELL DRAINED FROST
RESISTANT STRUCTURAL FILL
FIN GRADE
EXIST CONC
BEAM
EXIST CONC
WALL
(4)-3/4" DIA HILTI HIT-HY
200 ADHESIVE ANCHORS
W/ 6" EMBED 5 1/2" GAGE
L5x3x1/2 8" LONG GALV
/2
/2
HORIZONTAL SLOT
#4@12 EW
M
IN
#4@12 EPOXY HILTI
HIT-HY 200 DWLS
W/ 4" EMBED (4
SIDES)
MIN
3"
EQUIPMENT ANCHORS
BY EQUIPMENT
MANUFACTURER
3" CLR TO END
OF LADDER WHEN
SUPPORTED FROM WALL
AL BAR 2 1/2"x1/2"
LADDER RAILS, PUNCH
TO RECEIVE RUNGS
1/2"ø SS EXPANSION
ANCHOR (USE FLOOR
SUPPORT UNLESS
IMPRACTICAL)
1/4
TYP 3 SIDES
MIN
7"
M
IN
HIGHEST RUNG EVEN
WITH UPPER PLATFORM
M A
X
O C
M A
X
" M
A X
1/2"ø 316 SS
EXPANSION ANCHOR
KNURLED RUNGS,
ALUMINUM BAR 3/4"ø
EQUALLY SPACED @12" OC
1/4
(TYP)
1/4
AL BENT BAR
2 1/2"x 1/2" WALL
SUPPORT BRACKET
M
IN
SPLICE PLATE, AL BAR
2 1/2"x1/2" WITH (3)-5/8"ø SS
BOLTS EACH SIDE OF SPLICE
STAGGERED. BOLT HEADS
TO BE COUNTERSUNK OR OF
THE BUTTON TYPE
SPLICE DETAIL
BRACKET TO RAIL
TYP 3 SIDES1/4
1/4
(TYP)
PLUG WELD
1/4" DEEP (TYP)
RUNGS AL BAR 3/4"ø
AL BAR 2 1/2"x1/2"
LADDER RAILS, PUNCH TO
RECEIVE RUNGS
WALL SUPPORT BRACKETS
AL BENT BAR 2 1/2"x1/2"
@ MAX 4'-0" OC, VERT
1/2"ø SS EXPANSION ANCHORS
(WHEN ATTACHING TO
MASONRY USE 1/2"ø SS
ADHESIVE ANCHOR)
7"
FINISH FLOOR
LADDER PLAN
1/4" BENT PLATE
3/16
TYP
3/16
TYP
SKYLIGHT SEE ARCH DRAWINGS
EXIST CONC
BEAM
W8 TO BE SNUG TIGHT TO
BOTTOM OF EXISTING
FLOOR
HORIZONTAL SLOT IN ANGLE
(2)-3/4" DIA HILTI HIT-HY
200 ADHESIVE ANCHORS
W/ 6" EMBED 5 1/2" GAGE
W
ENDELL YANG
P R
O F
E
S S IO NA L ENG
IN
E
E R
No. 10808959
R
EG IS T ERED
STATE OF
I N D I A N A
A B C D E F
C
D M
S M
IT
H
A L
L R
IG
H
T S
R E
S E
R V
E D
R
E U
S E
O F
D O
C U
M E
N T
S T
H E
E S
E D
O C
U M
E N
T S
A N
D D
E S
IG
N
S P
R O
V
ID
E D
B Y
P R
O F
E S
S
IO
N A
L S
E R
V
IC
E
IN
C O
R P
O R
A T
E D
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F C
D M
S M
IT
H
A N
D A
R E
N O
T T
O B
E U
S E
R
IN
W H
O L
E O
R P
A R
T F
O R
A N
Y O
T H
E R
P R
O J E
C T
W
IT
H O
U T
T H
E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N
O F
C D
M S
M
IT
H
DATE:
APPROVED BY:
CROSS CHK'D BY:
SHEET CHK'D BY:
DRAWN BY:
DESIGNED BY:
JUNE 2020
563 South Lake Street, Suite 1A Gary, Indiana 46403
PROJECT NO.
FILE NAME:
SHEET NO.
REMARKSCHKDDRWNDATE
REV.
NO.
HG
GARY SANITARY DISTRICT
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
GARY, INDIANA
29021-228129
SOLICITATION NUMBER W912P620B0020
06/26/2020
B. CUNNINGHAM
B. CUNNINGHAM
W. YANG
L. SMITH-HORN
W. YANG
STRUCTURAL SECTIONS AND DETAILS
S-5
SEZ001GR.rvt
1" = 1'-0"S-3
1 SECTION
1" = 1'-0"S-3
2 SECTION
1" = 1'-0"S-3
3 SECTION
1/2" = 1'-0"S-3
4 SECTION
_ 1" = 1'-0"
A DETAIL
DETAIL
1/2" = 1'-0"
C
OUTDOOR EQUIPMENT PAD
1" = 1'-0"S-3
5 SECTION
DETAIL
1" = 1'-0"
B
EQUIPMENT PAD ON EXISTING CONC
DETAIL
1" = 1'-0"
D
ALUMINUM LADDER
3/4" = 1'-0"S-3
6 SECTION
1" = 1'-0"S-3
7 SECTION
TABLE 1 - REQUIRED VERIFICATION AND INSPECTION OF SOILS (NCBC, TABLE 1704.7)
REFER TO THE
FOLLOWING TABLES
FOR ADDITIONAL
RELATED SPECIAL
INSPECTIONS
VERIFY MATERIALS BELOW ALL FOUNDATIONS ARE
ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY
VERIFY EXCAVATIONS ARE EXTENDED TO PROPER
DEPTH AND HAVE REACHED PROPER MATERIAL
PERFORM CLASSIFICATION AND TESTING OF
COMPACTED FILL MATERIALS
VERIFY USE OF PROPER MATERIALS, DENSITIES,
AND LIFT THICKNESSES DURING PLACEMENT AND
COMPACTION OF COMPACTED FILL
PRIOR TO PLACEMENT OF COMPACTED FILL,
OBSERVE SUBGRADE AND VERIFY THAT SITE
HAS BEEN PREPARED PROPERLY
1704.7
1704.7
1704.7
1704.7
1704.7
CONTRACT
DOCUMENTS
AND
GEOTECHNICAL
REPORT
X
X
X
X
REMARKS
PERIODIC
INSPECTION FREQUENCY
CONTINUOUS
REFERENCE
STANDARD
NCBC
REFERENCE
VERIFICATION AND INSPECTION
X
INSPECTION OF BOLTS TO BE INSTALLED IN CONCRETE
PRIOR TO AND DURING PLACEMENT OF CONCRETE
INSPECTION OF CONCRETE PLACEMENT
INSPECTION OF REINFORCING STEEL, INCLUDING
PRESTRESSING TENDONS, AND PLACEMENT
INSPECTION OF WELDING FOR REINFORCING STEEL IN
ACCORDANCE WITH IBC, TABLE 1704.3, ITEM 5B (WHEN
WELDING IS SPECIFIED OR APPROVED IN WRITING)
VERIFYING USE OF REQUIRED DESIGN MIX
AT THE TIME FRESH CONCRETE IS SAMPLED TO
FABRICATE SPECIMENS FOR STRENGTH TESTS,
PERFORM SLUMP AND AIR CONTENT TESTS, AND
DETERMINE THE TEMPERATURE OF THE CONCRETE
INSPECTION FOR MAINTENANCE OF SPECIFIED
CURING TEMPERATURE AND TECHNIQUES
INSPECTION OF PRESTRESSED CONCRETE:
a. APPLICATION OF PRESTRESSING FORCES
b. GROUTING OF BONDED PRESTRESSING TENDONS
IN THE SEISMIC-FORCE-RESISTING SYSTEM
ERECTION OF PRECAST CONCRETE MEMBERS
VERIFICATION OF IN-SITU CONCRETE STRENGTH, PRIOR
TO STRESSING OF TENDONS IN POST TENSIONED
CONCRETE AND PRIOR TO REMOVAL OF SHORES AND
FORMS FROM BEAMS AND STRUCTURAL SLABS
INSPECT FORMWORK FOR SHAPE, LOCATION AND
DIMENSIONS OF THE CONCRETE MEMBER BEING
FORMED
VERIFICATION AND INSPECTION OF ADHESIVE ANCHORS
AND DOWELS INSTALLED IN HARDENED CONCRETE.
ANCHOR PRODUCT NAME, TYPE, DIMENSIONS, HOLE
DIMENSIONS, COMPLIANCE WITH DRILL BIT
REQUIREMENTS, HOLE PREPARATION AND SURFACE
ROUGHNESS,CLEANLINESS OF THE HOLE AND ANCHOR,
ADHESIVE EXPIRATION DATE, ANCHOR/ADHESIVE
INSTALLATION, ANCHOR EMBEDMENT, AND TIGHTENING
TORQUE
INSPECTION OF MECHANICAL ANCHORS INSTALLED IN
HARDENED CONCRETE (EXPANSION ANCHORS AND
UNDERCUT ANCHORS)
VERIFICATION AND INSPECTION OF MECHANICAL
REINFORCING STEEL COUPLING SYSTEM (WHEN
SPECIFIED OR APPROVED IN WRITING). PRODUCT NAME
AND MODEL NUMBER/TYPE, REINFORCING STEEL GRADE
AND BAR DIAMETER(S) TO BE SPLICED. THREADED
SYSTEMS: END PLUGS INSTALLED OVER INTERNALLY
THREADED ENDS, INTERNAL AND EXTERNAL THREAD
CONDITION AND CLEANLINESS, PROPER LENGTH OF
INSERTION, AND TIGHTENED TO MANUFACTURER'S
RECOMMENDED TORQUE. SET SCREW TYPE SYSTEMS:
PROPER LENGTH OF INSERTION, SET SCREWS
TIGHTENED TO MANUFACTURER'S RECOMMENDED
TORQUE. OTHER TYPES OF MECHANICAL REINFORCING
STEEL COUPLING SYSTEMS OR SUBSTITUTIONS:
VERIFICATION AND INSPECTION REQUIREMENTS WILL
BE ESTABLISHED BY THE ENGINEER.
TABLE 2 - REQUIRED VERIFICATION AND INSPECTION OF
CONCRETE CONSTRUCTION (NCBC, TABLE 1704.4)
1704.4
1704.4
1704.4 1911.5 1912.1
ACI 318: SECTION 3.5
AND SECTIONS 7.1-7.7
X
PERIODIC
INSPECTION FREQUENCY
CONTINUOUS
REFERENCE STANDARD
NCBC
REFERENCE
VERIFICATION AND INSPECTION
X
SEE TABLE 3
X
PER ICC TEST REPORT FOR
COUPLING SYSTEM
ACI 318: CHAPTER 4, SECTIONS 5.2-5.4
1704.4
1905.1 1905.5
X
1704.4 1905.6
X
ACI 318: SECTIONS 5.6, 5.8
ASTM C172
ASTM C31
1704.4 1905.7 1905.8 1905.9 1905.10
X ACI 318: SECTIONS 5.9, 5.10
1704.4 1905.11 1905.12 1905.13
X ACI 318: SECTIONS 5.11-5.13
1704.4
X
X
ACI 318: SECTION 18.20
ACI 318: SECTION 6.2
1704.4 X
ACI 318: SECTION 18.18.4
1704.4 X
REQUIRED VERIFICATION AND INSPECTION OF POST INSTALLED CONCRETE CONCRETE
ANCHORS
1704.4 1912.1
1704.4 X ACI 318: SECTION 6.1.1
X ACI 318: SECTION 3.8.6, 8.1.3, 21.2.8
1703.4.2 X
PER ICC TEST REPORT FOR SPECIFIC
ANCHOR
W
ENDELL YANG
P R
O F
E
S S IO NA L ENG
IN
E
E R
No. 10808959
R
EG IS T ERED
STATE OF
I N D I A N A
A B C D E F
C
D M
S M
IT
H
A L
L R
IG
H
T S
R E
S E
R V
E D
R
E U
S E
O F
D O
C U
M E
N T
S T
H E
E S
E D
O C
U M
E N
T S
A N
D D
E S
IG
N
S P
R O
V
ID
E D
B Y
P R
O F
E S
S
IO
N A
L S
E R
V
IC
E
IN
C O
R P
O R
A T
E D
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F C
D M
S M
IT
H
A N
D A
R E
N O
T T
O B
E U
S E
R
IN
W H
O L
E O
R P
A R
T F
O R
A N
Y O
T H
E R
P R
O J E
C T
W
IT
H O
U T
T H
E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N
O F
C D
M S
M
IT
H
DATE:
APPROVED BY:
CROSS CHK'D BY:
SHEET CHK'D BY:
DRAWN BY:
DESIGNED BY:
JUNE 2020
563 South Lake Street, Suite 1A Gary, Indiana 46403
PROJECT NO.
FILE NAME:
SHEET NO.
REMARKSCHKDDRWNDATE
REV.
NO.
HG
GARY SANITARY DISTRICT
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
GARY, INDIANA
29021-228129
SOLICITATION NUMBER W912P620B0020
06/26/2020
B. CUNNINGHAM
B. CUNNINGHAM
W. YANG
L. SMITH-HORN
W. YANG
STRUCTURAL
SPECIAL INSPECTIONS I S-6
SEZ001GR.rvt
SCHEDULE OF SPECIAL INSPECTIONS:
NOTES:
1. THIS DRAWING IS PROVIDED TO OUTLINE THE MINIMUM LEVEL OF SPECIAL INSPECTIONS DURING CONSTRUCTION TO ENSURE CONFORMANCE TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. A STATEMENT OF SPECIAL INSPECTIONS WILL BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL AND SUBMITTED WITH THE BUILDING
PERMIT APPLICATION.
2. SPECIAL INSPECTIONS WILL BE CONDUCTED IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH IN CHAPTER 17
OF THE INTERNATIONAL BUILDING CODE (IBC).
3. IN ACCORDANCE WITH THE REQUIREMENTS OF CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE, THE OWNER WILL PROVIDE A SPECIAL INSPECTOR (AN APPROVED AGENCY OR AGENCIES, INDEPENDENT FROM THE CONTRACTOR AND EMPLOYING QUALIFIED PERSONNEL) TO PERFORM SPECIAL INSPECTIONS IDENTIFIED IN THE STATEMENT OF SPECIAL INSPECTIONS. THE SPECIAL INSPECTOR WILL FURNISH INSPECTION REPORTS TO THE ENGINEER AND
BUILDING OFFICIAL.
4. SPECIAL INSPECTIONS SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY FOR QUALITY CONTROL OF THE WORK OR FOR CONFORMANCE TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. DETECTION, OR FAILURE TO DETECT, DEFECTS IN THE WORK SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY TO CORRECT ALL DEFECTS IN THE WORK, WHETHER DETECTED OR NOT, AND OF RESPONSIBILITY FOR CONFORMANCE
TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
5. REMOVE AND REPLACE, OR REPAIR, DEFECTS IN THE WORK AND WORK NOT IN CONFORMANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL BEAR THE COSTS FOR THE INSPECTION OF ANY REPLACED OR REPAIRED PORTIONS OF THE WORK.
6. CONTRACTOR SHALL COOPERATE WITH SPECIAL INSPECTIONS BY PROVIDING SUFFICIENT NOTICE FOR THE SCHEDULING OF PERSONNEL AND BY ALLOWING FREE AND SAFE ACCESS TO THE WORK FOR OBSERVATION, VERIFICATION, SAMPLING AND INSPECTION. PROVIDE AND PERMIT THE USE OF LADDERS, SCAFFOLDING, INCIDENTAL EQUIPMENT, AND SAFETY EQUIPMENT AS MAY BE REQUIRED TO CONDUCT SPECIAL INSPECTIONS. ALL SUCH PROVISIONS FOR FREE AND SAFE ACCESS AND EQUIPMENT SHALL BE SAFE, IN GOOD WORKING CONDITION, AND
ERECTED, MAINTAINED, AND HANDLED BY QUALIFIED PERSONNEL.
7. SPECIAL INSPECTIONS DO NOT APPLY TO CONTRACTOR'S EQUIPMENT, TEMPORARY STRCUTURES USED FOR CONSTRUCTION, MEANS AND METHODS OF CONSTRUCTION, OR SITE SAFETY. CONTRACTOR SHALL REMAIN RESPONSIBLE FOR ADEQUACY AND SAFET OF EQUIPMENT, TEMPORARY STRUCTURES USED FOR CONSTRUCTION, MEANS AND METHODS OF CONSTRUCTION AND SITE SAFETY.
MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS,
NUTS AND WASHERS:
a. IDENTIFICATION MARKINGS TO CONFORM TO ASTM
STANDARDS SPECIFIED IN THE APPROVED
CONSTRUCTION DOCUMENTS
b. MANUFACTURER'S CERTIFICATE OF COMPLIANCE
REQUIRED
TABLE 3 - REQUIRED VERIFICATION AND INSPECTION OF
STEEL CONSTRUCTION (NCBC, TABLE 1704.3)
1704.3
AICS 360, SECTION A3.3 AND APPLICABLE
ASTM MATERIAL STANDARDS
X
PERIODIC
INSPECTION FREQUENCY
CONTINUOUS
REFERENCE STANDARD
NCBC
REFERENCE
VERIFICATION AND INSPECTION
X
INSPECTION OF HIGH-STRENGTH BOLTING:
a. SNUG-TIGHT JOINTS
b. PRETENSIONED AND SLIP-CRITICAL JOINTS USING
TURN-OF-NUT WITH MATCHMARKING,TWIST-OFF BOLT
OR DIRECT TENSION INDICATOR METHODS OF
INSTALLATION
c. PRETENSIONED AND SLIP-CRITICAL JOINTS USING
TURN-OF-NUT WITHOUT MATCHMARKING OR
CALIBRATED WRENCH METHODS OF INSTALLATION
1704.3 1704.3.3
X
X
X AICS 360, SECTION M2.5
MATERIAL VERIFICATION OF STRUCTURAL STEEL AND
COLD-FORMED STEEL DECK:
a. FOR STRUCTURAL STEEL, IDENTIFICATION MARKINGS
TO CONFORM TO AISC 360
b. FOR OTHER STEEL, IDENTIFICATION MARKINGS TO
CONFORM TO ASTM STANDARDS SPECIFIED IN THE
APPROVED CONSTRUCTION DOCUMENTS
c. MANUFACTURER'S CERTIFIED MILL TEST REPORTS
1704.3 X
X
X
AICS 360, SECTION M5.5
APPLICABLE ASTM MATERIAL STANDARDS
MATERIAL VERIFICATION OF WELD FILLER MATERIALS:
a. IDENTIFICATION MARKINGS TO CONFORM TO AWS
SPECIFICATION IN THE APPROVED CONSTRUCTION
DOCUMENTS
b. MANUFACTURER'S CERTIFICATE OF COMPLIANCE
REQUIRED
1704.3 X
X
AISC 360, SECTION A3.5 AND APPLICABLE
AWS A5 DOCUMENTS
INSPECTION OF WELDING:
a. STRUCTURAL STEEL AND COLD-FORMED STEEL
DECK
1) COMPLETE AND PARTIAL PENETRATION GROOVE
WELDS
2) MULTIPASS FILLET WELDS
3) SINGLE-PASS FILLET WELDS > 5/16"
4) PLUG AND SLOT WELDS
5) SINGLE-PASS FILLET WELDS < 5/16"
6) FLOOR AND ROOF DECK WELDS
b. REINFORCING STEEL (WHEN WELDING IS SPECIFIED
OR APPROVED IN WRITING)
1) VERIFICATION OF WELDABILITY OF REINFORCING
STEEL OTHER THAN ASTM A 706
2) REINFORCING STEEL RESISTING FLEXURAL AND
AXIAL FORCES IN INTERMDIATE AND SPECIAL
MOMENT FRAMES, AND BOUNDARY ELEMENTS OF
SPECIAL STRUCTURAL REINFORCED CONCRETE
SHEAR WALLS AND SHEAR REINFORCEMENT
3) SHEAR REINFORCEMENT
4) OTHER REINFORCING STEEL
1704.3
1704.3.1 X
X X X
X
X
AWS D1.1
AWS D1.3
1704.3 1704.3.1
X
X
X
X
AWS D1.4 AND ACI 318: SECTION 3.5.2
INSPECTION OF STEEL FRAME JOINT DETAILS FOR
COMPLIANCE:
a. DETAILS SUCH AS BRACING AND STIFFENING
b. MEMBER LOCATIONS
c. APPLICATION OF JOINT DETAILS AT EACH CONNECTION
1704.3 1704.3.2
X
X
X
TABLE 4 - LEVEL 1 REQUIRED VERIFICATION AND INSPECTION OF MASONRY
CONSTRUCTION (NCBC, TABLE 1704.5.1)
VERIFICATION OF f'm AND f'aac PRIOR TO
CONSTRUCTION EXCEPT WHERE SPECIFICALLY
EXEMPTED BY CODE
VERIFICATION OF SLUMP FLOW AND VSI AS DELIVERED
TO THE SITE FOR SELF-CONSOLIDATING GROUT
VERIFY GROUT PLACEMENT TO ENSURE COMPLIANCE
OBSERVE PREPARATION OF ANY REQUIRED GROUT
SPECIMENS, MORTAR SPECIMENS AND/OR PRISMS
VERIFY GROUTING OF PRESTRESSING BONDED
TENDONS TO ENSURE COMPLIANCE
VERIFY COMPLIANCE WITH REQUIRED INSPECTION
PROVISIONS OF THE CONSTRUCTION DOCUMENTS AND
THE APPROVED SUBMITTALS
1704.5.2 X
PERIODIC
INSPECTION FREQUENCY
CONTINUOUS
REFERENCE STANDARD
NCBC
REFERENCE
VERIFICATION AND INSPECTION
X
AS MASONRY CONSTRUCTION BEGINS VERIFY THE
FOLLOWING TO ENSURE COMPLIANCE :
a. PROPORTIONS OF SITE-PREPARED MORTAR
b. CONSTRUCTION OF MORTAR JOINTS
c. LOCATION OF REINFORCEMENT, CONNECTORS, PRE-STRESSING TENDONS AND ANCHORAGES
d. PRESTRESSING TECHNIQUE
e. GRADE AND SIZE OF PRESTESSING TENDONS AND
ANCHORAGES
DURING CONSTRUCTION VERIFY:
a. SIZE AND LOCATION OF STRUCTURAL ELEMENTS
b. TYPE, SIZE AND LOCATION OF ANCHORS, INCLUDING
OTHER DETAILS OF ANCHORAGE OF MASONRY TO
STRUCTURAL MEMBERS, FRAMES OR OTHER
CONSTRUCTION
c. SPECIFIED SIZE, GRADE AND TYPE OF REINFORCE-
MENT, ANCHOR BOLTS, PRESTRESSING TENDONS AND
ANCHORAGES
d. WELDING OF REINFORCING BARS (WHEN WELDING IS
SPECIFIED OR APPROVED IN WRITING)
e. PREPARATION, CONSTRUCTION AND PROTECTION OF
MASONRY DURING COLD WEATHER (TEMPERATURE
BELOW 40°F) OR HOT WEATHER (TEMPERATURE
ABOVE 90°F)
f. APPLICATION AND MEASUREMENT OF PRESTRESSING
FORCE
X
ACI 530.1 ARTICLE 1.5
1704.5.2 X ACI 530.1 ARTICLE 1.4B
1704.5.2
1704.5.2
ACI 530.1 ARTICLE 2.6A
ACI 530.1 ARTICLE 3.3B
ACI 530.1 ARTICLE 3.4, 3.6A
X
X
X ACI 530.1 ARTICLE 3.6B
ACI 530.1 ARTICLES 2.4B, 2.4H
ACI 530.1 ARTICLE 1.5B.1.b.3
1704.5.2 X ACI 530.1 ARTICLE 3.6B
1704.5.2 2104.3 2104.4
X ACI 530.1 ARTICLES 1.BC, 1.BD
1704.5.2
X
X
X
X
ACI 530 SECTIONS 2.1.7.7.2, 3.3.3.4(c)
ACI 530 SECTIONS 1.15, 1.16, 1.17
ACI 530.1 ARTICLES 2.4, 3.4
ACI 530.1 ARTICLE 3.3F
ACI 530 SECTIONS 1.2.2(e), 1.16.1
PRIOR TO GROUTING, VERIFY THE FOLLOWING TO
ENSURE COMPLIANCE:
a. GROUT SPACE IS CLEAN PRIOR TO GROUTING
b. PLACEMENT OF REINFORCEMENT AND CONNECTORS
AND PRESTRESSING TENDONS AND ANCHORAGES
c. PROPORTIONS OF SITE-PREPARED GROUT AND PRE-
STRESSING GROUT FOR BONDED TENDONS
d. CONSTRUCTION OF MORTAR JOINTS
X
X
ACI 530.1 ARTICLE 3.2D
ACI 530 SECTION 1.16,
ACI 530.1 ARTICLES 3.4, 3.6A
ACI 530.1 ARTICLE 3.3B
ACI 530.1 ARTICLE 2.6B
1704.5.2
1704.5.2 X ACI 530.1 ARTICLE 3.5
1704.5.2 X ACI 530.1 ARTICLE 3.6C
1704.5.2 2105.2.2 2105.3
ACI 530.1 ARTICLE 1.4BX
W
ENDELL YANG
P R
O F
E
S S IO NA L ENG
IN
E
E R
No. 10808959
R
EG IS T ERED
STATE OF
I N D I A N A
A B C D E F
C
D M
S M
IT
H
A L
L R
IG
H
T S
R E
S E
R V
E D
R
E U
S E
O F
D O
C U
M E
N T
S T
H E
E S
E D
O C
U M
E N
T S
A N
D D
E S
IG
N
S P
R O
V
ID
E D
B Y
P R
O F
E S
S
IO
N A
L S
E R
V
IC
E
IN
C O
R P
O R
A T
E D
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F C
D M
S M
IT
H
A N
D A
R E
N O
T T
O B
E U
S E
R
IN
W H
O L
E O
R P
A R
T F
O R
A N
Y O
T H
E R
P R
O J E
C T
W
IT
H O
U T
T H
E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N
O F
C D
M S
M
IT
H
DATE:
APPROVED BY:
CROSS CHK'D BY:
SHEET CHK'D BY:
DRAWN BY:
DESIGNED BY:
JUNE 2020
563 South Lake Street, Suite 1A Gary, Indiana 46403
PROJECT NO.
FILE NAME:
SHEET NO.
REMARKSCHKDDRWNDATE
REV.
NO.
HG
GARY SANITARY DISTRICT
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
GARY, INDIANA
29021-228129
SOLICITATION NUMBER W912P620B0020
06/26/2020
B. CUNNINGHAM
B. CUNNINGHAM
W. YANG
L. SMITH-HORN
W. YANG
STRUCTURAL
SPECIAL INSPECTIONS II S-7
SEZ001GR.RVT
GARY SANITARY DISTRICT
GARY, INDIANA
SOLICITATION NUMBER W912P620B0020
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
563 South Lake Street, Suite 1A
Gary, Indiana 46403
M-1
MECHANICAL LEGEND
AND ABBREVIATIONS
GARY SANITARY DISTRICT
GARY, INDIANA
SOLICITATION NUMBER W912P620B0020
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
563 South Lake Street, Suite 1A
Gary, Indiana 46403
M-2
MECHANICAL NOTES AND
PIPE AND VALVE SCHEDULES
GRIT DEWATERING IMPROVEMENTS PROCESS VALVE SCHEDULE
GRIT DEWATERING IMPROVEMENTS PROCESS PIPE SCHEDULE
GARY SANITARY DISTRICT
GARY, INDIANA
SOLICITATION NUMBER W912P620B0020
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
563 South Lake Street, Suite 1A
Gary, Indiana 46403
PLAN
PLAN
N
M-3
DETRITOR BUILDING GRIT PUMPING
DEMOLITION - PLANS
GARY SANITARY DISTRICT
GARY, INDIANA
SOLICITATION NUMBER W912P620B0020
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
563 South Lake Street, Suite 1A
Gary, Indiana 46403
PLAN
N
M-4
SCREEN BUILDING GRIT WASHING
DEMOLITION - PLAN
N
M-5
DETRITOR BUILDING GRIT
NEW WORK - PLANS
GARY SANITARY DISTRICT
GARY, INDIANA
SOLICITATION NUMBER W912P620B0020
WASTEWATER TREATMENT PLANT
GRIT DEWATERING IMPROVEMENTS
ISSUED FOR BID
563 South Lake…