A-101 G:\My Drive\20 Pierre ADA Toilet Rooms\CAD\Pierre Toilet Working.pln

GSA, Region 8 South Dakota Field Office Rapid City, South Dakota 57701

DEMOLITION PLAN

27-Mar-20Second Floor Toilet

Room Remodel

D-5

D-1 D-1

D-1

D-1

D-3 D-1

D-3

D-2

D-2

D-3

D-4

D-4

D-4

D-6

DEMOLITION KEY NOTES

D-1 REMOVE & DISGARD PLUMBING FIXTURES

D-2 REMOVE & DISGARD TOILET PARTITIONS

D-3 REMOVE ALL FLOOR, WALL & CEILING FINISHES; SALVAGE SPRINKLER HEADS FOR

REUSE

D-4 DEMOLISH WALLS & DOORS TO EXTENT SHOWN; PROVIDE BRACING AS NEEDED

D-5 RELOCATE WATER FOUNTAIN, TO INCLUDE SUPPLY & WASTE; LOCATE PER RENO

PLAN

D-6 RELOCATE PLUMBING LINES, AS NEEDED; UTILIZE REMAINDER OF PLUMBING

CHASE

N

SCALE: 1/4" = 1'-0"

DEMOLITION PLAN

KristenCFeickert Typewriter PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.

CONTRACTOR SHALL FIELD VERIFY ALL SITE CONDITIONS AND MEASUREMENTS. SEE

SPECIFICATIONS FOR FURTHER INSTRUCTIONS.

A-102

GSA, Region 8 South Dakota Field Office Rapid City, South Dakota 57701

RENOVATION PLAN

27-Mar-20Second Floor Toilet

Room Remodel

CL

CL

CLCL CL

3'-0" C

LR

, M

IN

1'-0" 3'-4"

'-6

'-6

4'-11" CLR

'-8

" C L

R

", M

A X

2'-6" 2'-2"

VIF 1'-6", MIN 3'-4"

2'-8", CLR

A

-2

N

E

S

W

N

E

S

W

NEW LINTEL, OVERHEAD NEW LINTEL, OVERHEAD

W

W

W

W

F

F

F

F

F

F

F

F

F

F02

F

FD FD

WOMEN

MEN

W

W

W

W

W

F

F

'-3

'-0

" C L R

/4

'-0

1'-6"

'-0

" C L R

'-0

" C L R

2'-7"

W02

RENOVATION KEY NOTES

1 INSTALL FLOOR TILE; DISH

OUT TILE AT FLOOR

DRAINS (FD)

2 INSTALL CARPET TO

MATCH ADJ CORRIDOR

3 METAL FLOORING

TRANSITION STRIP

WALL TYPES

F-01 MORTAR, WALL TILE

(ON EXG WALL)

F-02 5/8” GWB (ON EXG WALL)

W-01 4” CMU, MORTAR, WALL

TILE

W-02 5/8” GWB, 3 5/8” MTL

STUD, 5/8” GWB

W-03 5/8” GWB, 3 5/8” MTL STUD

W-04 4” CMU (ALIGNED W/ ADJ,

EXG WALL)

W-05 5/8” GWB, 3 5/8” MTL

STUD, 5/8” TILE BACKER

BOARD, MORTAR, WALL

TILE

N

SCALE: 1/2" = 1'-0"

ENLARGED FLOOR PLAN

KristenCFeickert Typewriter PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.

A-103

GSA, Region 8 South Dakota Field Office Rapid City, South Dakota 57701

REFLECTED CEILING PLAN

27-Mar-20Second Floor Toilet

Room Remodel

E Q

EQEQ

"4'-5" 4'-6"

5'-0" 2'-0"

EQ EQ

8'-0"

8'-0"

8'-0"

C-1

C-1

C-1

C-1

C-1

C-1

C-3

C-3

EQ EQ

C-2

C-2

C-2

NOT IN CONTRACT

CEILING KEY NOTES

C-1 INSTALL NEW 5/8" GYPSUM BOARD CEILING; RE-INSTALL SPRINKLER HEADS IAW

NFPA 72; RE-INSTALL HORNS/STROBES IAW NFPA 72

C-2 CONTROL JOINT

C-3 INSTALL NEW EXHAUST FAN CEILING GRILLE; REUSE EXISTING EXHAUST FAN &

DUCTING

TILE

N

SCALE: 1/4" = 1'-0"

REFLECTED CEILING PLAN

KristenCFeickert Typewriter PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.

A-201

GSA, Region 8 South Dakota Field Office Rapid City, South Dakota 57701

INTERIOR ELEVATIONS

27-Mar-20Second Floor Toilet

Room Remodel

M A

X B

E D

H T

M

A X

H A

N D

L E

H T

3'-0"

4'-4"

T Y

P

2'-0"

WALL TILE, 6 X 24,

STACKED BOND

GWB, LEVEL-4 FINISH, PAINT

TO MATCH CORRIDOR

BRIDGE PARTIALLY

ABANDONED CHASE AREA;

MAKE LEVEL W/ ADJ SUB-

FLOOR

COVER PARTIALLY

ABANDONED CHASE AREA;

MAKE FLUSH W/ ADJ CEILING

DESIGN & INSTALL NEW LINTEL;

WRAP W/ GWB & FINISH TO

MATCH CORRIDOR

CUT R.O. FOR NEW DOOR;

DESIGN & INSTALL NEW LINTEL

NEW GWB CEILING

SURFACE-MOUNTED

BABY CHANGING

STATION

CONTROL JOINT

CORNER GUARD TO HEIGHT

OF OPENING, TYP

RUBBER WALL BASE; MATCH

CORRIDOR

AUTOMATIC DOOR

ACTUATOR

AUTOMATIC DOOR ACTUATOR

SCALE: 1/2" = 1'-0"

NORTH ELEVATION - WOMEN

KristenCFeickert Typewriter PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.

A-202

GSA, Region 8 South Dakota Field Office Rapid City, South Dakota 57701

INTERIOR ELEVATIONS

27-Mar-20Second Floor Toilet

Room Remodel

3'-6" 1'-0"

M

IN

4", MAX

TOILET TISSUE

DISPENSER, TYP, OFOI

FLOOR-MOUNTED,

FLOOR OUTLET, REAR

SPUD INLET ADA

WATER CLOSET

RESTROOM PARTITION,

FLOOR-MOUNTED W/

OVERHEAD BRACE

WALL TILE, 6 X 24,

STACKED BOND

SANITARY NAPKIN

DISPOSAL, TYP IN

WOMEN'S

NEW GWB CEILING

GRAB BARS, IAW ABAAS

SURFACE-MOUNTED

BABY CHANGING

STATION

17" RIM HT

SCALE: 1/2" = 1'-0"

EAST ELEVATION - WOMEN

KristenCFeickert Typewriter PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.

A-203

GSA, Region 8 South Dakota Field Office Rapid City, South Dakota 57701

INTERIOR ELEVATIONS

27-Mar-20Second Floor Toilet

Room Remodel

CL CL

3'-0"

1'-0" 2'-0"

1'-6"

M

A X

M

IN

M

IN

1'-6"

TOILET TISSUE

DISPENSER, OFOI

FLOOR-MOUNTED,

FLOOR OUTLET, REAR

SPUD INLET ADA

WATER CLOSET, TYP

RESTROOM PARTITION,

FLOOR-MOUNTED W/

OVERHEAD BRACE

WALL TILE, 6 X 24,

STACKED BOND

GWB, LEVEL-4 FINISH, PAINT

TO MATCH CORRIDOR

HAND TOWEL

DISPENSER, OFOI

CONCEALED SENSOR

HARDWIRED FLUSHOMETER

W/ PUSH BUTTON, TYP

GRAB BARS, IAW ABAAS

RECESSED FRAME W/

BACK PANEL & WASTE

RECEPTACLE; COORD W/

HAND TOWEL DISPENSER

BRIDGE PARTIALLY ABANDONED

CHASE AREA; MAKE LEVEL W/

ADJ SUB-FLOOR

COVER PARTIALLY

ABANDONED CHASE AREA;

MAKE FLUSH W/ ADJ CEILING

DESIGN & INSTALL NEW LINTEL;

WRAP W/ GWB & FINISH TO

MATCH CORRIDOR

CUT R.O. FOR NEW DOOR;

DESIGN & INSTALL NEW LINTEL

NEW GWB CEILING

CONTROL JOINT

RUBBER WALL BASE; MATCH

CORRIDOR

CORNER GUARD TO HEIGHT

OF OPENING, TYP

METAL TRIM AT

OUTSIDE CORNER

17" RIM HT17" RIM HT

SCALE: 1/2" = 1'-0"

SOUTH ELEVATION - WOMEN

KristenCFeickert Typewriter PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.

A-204

GSA, Region 8 South Dakota Field Office Rapid City, South Dakota 57701

INTERIOR ELEVATIONS

27-Mar-20Second Floor Toilet

Room Remodel

CL

VIF 4'-10"

NEW GWB CEILING

METAL TRIM AT

OUTSIDE CORNER

TOILET TISSUE

DISPENSER, TYP, OFOI

FLOOR-MOUNTED,

FLOOR OUTLET, REAR

SPUD INLET ADA

WATER CLOSET

RESTROOM PARTITION,

FLOOR-MOUNTED W/

OVERHEAD BRACE

WALL TILE, 6 X 24,

STACKED BOND

LIGHTED MIRROR,

24 X 36

SELF-CLOSING WOOD

DOOR W/ 10" X 24" LOUVER

WALL-MOUNTED WASH

BASIN W/ SHROUD &

SENSOR FAUCET

SANITARY NAPKIN

DISPOSAL, TYP IN

WOMEN'S

INSTALL BLOCKING

BETWEEN FRAMING

17" RIM HT

SCALE: 1/2" = 1'-0"

WEST ELEVATION - WOMEN

KristenCFeickert Typewriter PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.

A-205

GSA, Region 8 South Dakota Field Office Rapid City, South Dakota 57701

INTERIOR ELEVATIONS

27-Mar-20Second Floor Toilet

Room Remodel

CLCL

3'-0"

1'-6"

2'-0" 1'-0"

1'-6"

" 2

TOILET TISSUE

DISPENSER, OFOI

FLOOR-MOUNTED,

FLOOR OUTLET, REAR

SPUD INLET ADA

WATER CLOSET, TYP

RESTROOM PARTITION,

FLOOR- & CLG-

MOUNTED

WALL TILE, 6 X 24,

STACKED BOND

CONCEALED SENSOR

HARDWIRED FLUSHOMETER

W/ PUSH BUTTON, TYP

GRAB BARS, IAW ABAAS, TYP

NEW GWB CEILING

HIGH-EFFICIENCY

WASHOUT URINAL W/

REAR SPUD INLET

DESIGN & INSTALL NEW LINTEL;

WRAP W/ GWB & FINISH TO

MATCH CORRIDOR

GWB, LEVEL-4 FINISH, PAINT

TO MATCH CORRIDOR

METAL TRIM, TYP

NEW FRAME & DOOR,

PAINT TO MATCH ADJ WALL

6" TILE BASE

4" RUBBER BASE

CORNER GUARD TO

HEIGHT OF OPENING, TYP

CONTROL JOINT

17" RIM HT

SCALE: 1/2" = 1'-0"

NORTH ELEVATION - MEN

KristenCFeickert Typewriter PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.

A-206

GSA, Region 8 South Dakota Field Office Rapid City, South Dakota 57701

INTERIOR ELEVATIONS

27-Mar-20Second Floor Toilet

Room Remodel

1'-0" 3'-6"

4", MAX

TOILET TISSUE

DISPENSER, TYP, OFOI

FLOOR-MOUNTED,

FLOOR OUTLET, REAR

SPUD INLET ADA

WATER CLOSET

RESTROOM PARTITION,

FLOOR- & CLG-

MOUNTED W/

WALL TILE, 6 X 24,

STACKED BONDEXTENT OF TOILET

PARTITION

NEW GWB CEILING

GRAB BARS, IAW ABAAS

NEW FRAME & DOOR,

PAINT TO MATCH ADJ WALL

SURFACE-MOUNTED

BABY CHANGING

STATION

6" TILE BASE

METAL TRIM, TYP

17" RIM HT

SCALE: 1/2" = 1'-0"

EAST ELEVATION - MEN

KristenCFeickert Typewriter PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.

A-207

GSA, Region 8 South Dakota Field Office Rapid City, South Dakota 57701

INTERIOR ELEVATIONS

27-Mar-20Second Floor Toilet

Room Remodel

7'-4"

M A

X B

E D

H T

M

A X

H A

N D

L E

H T

2'-0"

CONTROL JOINT

WALL TILE, 6 X 24,

STACKED BOND

GWB, LEVEL-4 FINISH, PAINT

TO MATCH CORRIDOR

DESIGN & INSTALL NEW LINTEL;

WRAP W/ GWB & FINISH TO

MATCH CORRIDOR

CUT R.O. FOR NEW DOOR;

DESIGN & INSTALL NEW LINTEL

NEW GWB CEILING

SURFACE-MOUNTED

BABY CHANGING

STATION

METAL TRIM AT OUTSIDE

CORNER

4" RUBBER BASE

AUTOMATIC DOOR ACTUATOR

CORNER GUARD TO HEIGHT

OF OPENING, TYP

SCALE: 1/2" = 1'-0"

SOUTH ELEVATION - MEN

KristenCFeickert Typewriter PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.

A-208

GSA, Region 8 South Dakota Field Office Rapid City, South Dakota 57701

INTERIOR ELEVATIONS

27-Mar-20Second Floor Toilet

Room Remodel

CLCL

M

A X

2'-6" 2'-2"

4" 1'-2" 1'-3"

LIGHTED MIRROR,

24 X 36

SELF-CLOSING WOOD

DOOR W/ 10" X 24" LOUVER

WALL-MOUNTED WASH

BASIN W/ SHROUD &

SENSOR FAUCET

HAND TOWEL

DISPENSER, OFOI

SURFACE-MOUNTED

FRAME & WASTE

RECEPTACLE; CAPACITY

& APPEARANCE TO

MATCH WOMEN'S ROOM

GWB, LEVEL-4 FINISH,

PAINT TO MATCH

CORRIDOR

WALL TILE, 6 X 24,

STACKED BOND

NEW GWB CEILING

HIGH-EFFICIENCY

WASHOUT URINAL W/

REAR SPUD INLET

WALL TILE, 6 X 24,

STACKED BOND

METAL TRIM, TYP

6" TILE BASE

GWB, TO CORNER

AUTOMATIC DOOR

ACTUATOR

SCALE: 1/2" = 1'-0"

WEST ELEVATION - MEN

KristenCFeickert Typewriter PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.

A-209

GSA, Region 8 South Dakota Field Office Rapid City, South Dakota 57701

CORRIDOR ELEVATION

27-Mar-20Second Floor Toilet

Room Remodel

CL

M A

X S

P O

U T

H T

M

IN

C L E

A R

EQ EQ

M

IN

M A

X B

R A

IL

L E

H T

INSTALL TOILET ROOM SIGN; MATCH EXG SIGNS, TYP

REINSTALL DRINKING FOUNTAIN

CORNER GUARD TO HT OF OPENING, TYP

REPAIR PLASTER, AS REQ'D; LEVEL 4

4" RUBBER BASE TO MATCH CORRIDOR4" RUBBER BASE TO MATCH CORRIDOR

PAINT WALL, OUTSIDE CORNER TO OUTSIDE CORNER

SCALE: 1/2" = 1'-0"

CORRIDOR ELEVATION

KristenCFeickert Typewriter PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.