This document outlines a federal contract opportunity for transaction window replacement services. The General Services Administration (GSA) Region 5 intends to issue a Request for Proposals (RFP) to provide and install break resistant transaction windows for the U.S. District Court Clerk's Office Reception Desk and replace an existing employee entry turnstile located at the Robert Grant Federal Building & U.S. Courthouse in South Bend, Indiana. The estimated value is between $100,000 and $250,000. The solicitation will be issued on or around February 17, 2023 and remain open for 30 days. A firm-fixed price construction contract will be awarded by April 2023, requiring wage compliance and payment/performance bonds. The opportunity is designated as a 100% total small business set-aside for NAICS 236220 contractors registered in SAM.gov.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET INDEX
PREPARED FOR:
NORTH
KEY MAP
DATE: 10/28/2020
PROJECT NO: 47PF0020F0874
BUILDING NO: IN0300
BED PROJECT NO: 17005-020019-00-0000
PROJECT ADDRESSES: 204 S. MAN ST
SOUTH BEND, IN
GENERAL NOTES
G000 COVER SHEET
G001 LOCATION MAP
G002 ADA ACCESSIBILITY AND CODE STANDARDS
G003 CODE SHEET
A100 US. DISTRICT COURT CLERK'S OFFICE RECEPTION DESK - DEMO & NEW WORK FLOOR PLANS
A101 US. DISTRICT COURT CLERK'S OFFICE RECEPTION DESK - DEMO & NEW WORK RCP
A112 ENTRY TURNSTILE - DEMO & NEW WORK FLOOR PLANS
A300 INTERIOR ELEVATIONS
A600 SECTIONS AND DETAILS
FP130 FIRE PROTECTION FLOOR PLANS
M000 MECHANICAL STANDARDS
M130 MECHANICAL FLOOR PLANS
E000 ELECTRICAL SYMBOLS & ABBREVIATIONS
E130 LIGHTING FLOOR PLANS
E131 POWER AND SYSTEM FLOOR PLANS
E132 POWER AND SYSTEM FLOOR PLANS
E200 ELECTRICAL CONDUIT ROUTE PLANS
1. THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF THE ARCHITECTURAL
DESIGN CONCEPT, DIMENSIONS, MAJOR ELEMENTS AND MATERIALS. THESE DRAWINGS DO NOT
NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL COMPLETION OF THE PROJECT. ALL CONTRACTORS SHALL FURNISH ALL OF THOSE ITEMS AND LABOR REQUIRED FOR THE
FULL COMPLETION OF THIS PROJECT IN A FIRST CLASS WORKMANSHIP-LIKE MANNER.
2. ALL WORK IS TO BE PERFORMED FROM FINAL CONSTRUCTION DOCUMENTS ONLY AND A COPY OF THE
APPROVED FINAL SET MUST BE LOCATED ON THE SITE AT ALL TIMES. ALL CONTRACTOR'S
SUBCONTRACTORS SHALL BE GIVEN FULL SETS OF FINAL CONSTRUCTION DOCUMENTS WITH NO
SHEETS EXCLUDED.
3. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS HOLD PRIORITY OVER APPARENT SCALE.
DIMENSIONS ARE TO THE FACE OF FINISHED ELEMENTS OR TO THE CENTERLINE OF ELEMENTS UNLESS NOTED OTHERWISE. CONTRACTOR TO VERIFY CRITICAL DIMENSIONS WITH THE GOVERNMENT PRIOR TO
COMMENCING WORK.
4. ALL EXISTING WALLS AND PARTITIONS ARE DIMENSIONED TO THE FACE OF WALLS. ALL NEW PARTITIONS
ARE DIMENSIONED TO THE CENTERLINE OF WALL.
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
LIMITED OFFICIAL USE
MARK DESCRIPTION DATE
t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
©2020 Bailey Edward Design Design Firm License No. 184-001962
NAME
STREET
CITY/STREET/ZIP
BUILDING NO.
OTHER
BUILDING NOs.
PROJECT
DESCRIPTION
PROJECT NO.
DRAWING TITLE
TYPE
FILE NAME
FLOOR NO.
DRAWN BY
CHECKED BY
DRAWING NO.
17005 - 020019 - 00
AM SHEET SIZE: 24 X 36
DATE: 09.24.20
SHEET OF
B U
I L D
I N
G P
J C
T
D R
A W
I N
G
SH
USDC & USBC TRANSACTION WINDOWS
(IN0096ZZ)
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST,
SOUTH BEND, IN 46601-2122
100% CD 10.28.2022
GENERAL SERVICES ADMINISTRATION
REGION 5 CHICAGO, IL
ROBERT GRANT FEDERAL BLDG
& U.S. COURTHOUSE,
204 S. MAIN ST, SOUTH BEND, IN
46601-2122
(IN0096ZZ)
ROBERT GRANT FEDERAL BLDG.
& US. COURTHOUSE
204 S MAIN ST,
SOUTH BEND, IN 46601-2122
100% CD / OCTOBER 28, 2022
USBC TRANSACTION WINDOWS
CHICAGO, IL 60604
230 S. DEARBORN STREET
PBS SOUTHER SERVICE CENTER OPERATIONS DIVISION
CHICAGO, IL 60601
35 EAST WACKER DR. SUITE 2800
BAILEY EDWARD ARCHITECTS
ARCHITECT
GOVERNMENT TEAM
ROBIN WHITEHURST, PROJECT PRINCIPAL
SUSAN HICKEY, PROJECT ARCHITECT
CARY KUBIAK, PROJECT MANAGER & CONTRACTING OFFICER'S REPRESENTATIVE
ANEESAH MUHAMMAD, CONTRACTING OFFICER
JIM MORRISON, PROPERTY MANAGER
KENT LOCKE, PROJECT ENGINEER
PBS SOUTHERN SERVICE CENTER OPERATIONS DIVISION
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
LIMITED OFFICIAL USE
MARK DESCRIPTION DATE
t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
©2020 Bailey Edward Design Design Firm License No. 184-001962
NAME
STREET
CITY/STREET/ZIP
BUILDING NO.
OTHER
BUILDING NOs.
PROJECT
DESCRIPTION
PROJECT NO.
DRAWING TITLE
TYPE
FILE NAME
FLOOR NO.
DRAWN BY
CHECKED BY
DRAWING NO.
17005 - 020019 - 00
AM SHEET SIZE: 24 X 36
DATE: 09.24.20
SHEET OF
B U
I L D
I N
G P
J C
T
D R
A W
I N
G
SH
USDC & USBC TRANSACTION WINDOWS
(IN0096ZZ)
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST,
SOUTH BEND, IN 46601-2122
100% CD 10.28.2022
GENERAL SERVICES ADMINISTRATION
REGION 5 CHICAGO, IL
ROBERT GRANT FEDERAL BLDG
& U.S. COURTHOUSE,
204 S. MAIN ST, SOUTH BEND, IN 46601-2122
(IN0096ZZ)
NORTH
VICINITY MAP
LOCATION MAP
· US. DISTRICT COURT CLERK'S OFFICE RECEPTION DESK
· ENTRY TURNSTILE REPLACEMENT
PROPERTY MANAGER:
· JIM MORRISON
204 S. MAIN ST,
SOUTH BEND, IN 46601-2122
CHAPTER 3: BUILDING BLOCKS
30 min
48 min m i n m i n
(a) forward
(b) parallel m in
24 min m in
36 min
12 min
12 min
60 min base ar m ar m
304 TURNING SPACE
304.3.1 CIRCULAR SPACE. THE TURNING SPACE SHALL BE A SPACE OF 60 INCHES (1525 MM) DIAMETER MINIMUM.
THE SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH 306.
304.3.2 T-SHAPED SPACE. THE TURNING SPACE SHALL BE A T-SHAPED SPACE WITHIN A 60 INCH (1525 MM) SQUARE MINIMUM WITH ARMS AND BASE 36 INCHES (915 MM) WIDE MINIMUM. EACH ARM OF THE T SHALL BE CLEAR OF OBSTRUCTIONS 12 INCHES (305 MM) MINIMUM IN EACH DIRECTION AND THE BASE SHALL BE CLEAR OF OBSTRUCTIONS 24 INCHES (610 MM) MINIMUM. THE SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE
CLEARANCE COMPLYING WITH 306 ONLY AT THE END OF EITHER THE BASE OR ONE ARM.
FIGURE 304.3.2 T-SHAPED TURNING SPACE
FIGURE 305.5 POSITION OF CLEAR FLOOR OR GROUND SPACE
10 max m ax m in
10 max m ax m ax m ax
5 46 m ax
> 10-24 max 255-610
(a) (b)
308.3 SIDE REACH.
308.3.1 UNOBSTRUCTED. WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE SIDE REACH IS UNOBSTRUCTED, THE HIGH SIDE REACH SHALL BE 48 INCHES (1220 MM) MAXIMUM AND THE LOW SIDE REACH SHALL BE 15 INCHES (380 MM) MINIMUM ABOVE THE FINISH FLOOR OR
308.3.2 OBSTRUCTED HIGH REACH. WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE HIGH SIDE REACH IS OVER AN OBSTRUCTION, THE HEIGHT OF THE OBSTRUCTION SHALL BE 34 INCHES (865 MM) MAXIMUM AND THE DEPTH OF THE OBSTRUCTION SHALL BE 24 INCHES (610 MM) MAXIMUM.
THE HIGH SIDE REACH SHALL BE 48 INCHES (1220 MM) MAXIMUM FOR A REACH DEPTH OF 10 INCHES (255 MM) MAXIMUM. WHERE THE REACH DEPTH EXCEEDS 10 INCHES (255 MM), THE HIGH SIDE REACH SHALL BE 46 INCHES
(1170 MM) MAXIMUM FOR A REACH DEPTH OF 24 INCHES (610 MM) MAXIMUM.
FIGURE 308.3.2 OBSTRUCTED HIGH SIDE REACH
CHAPTER 9: BUILT-IN ELEMENTS
904.3.3 SALES AND SERVICE COUNTERS.
SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH 904.4.1 OR 904.4.2.
THE ACCESSIBLE PORTION OF THE COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR SERVICE
EXCEPTION: IN ALTERATIONS, WHEN THE PROVISION OF A COUNTER COMPLYING WITH 904.4 WOULD RESULT IN A REDUCTION OF THE NUMBER OF EXISTING COUNTERS AT WORK STATIONS OR A REDUCTION OF THE NUMBER OF EXISTING MAIL BOXES, THE COIUNTER SHALL BE PERMITTED TO HAVE A PORTION WHICH IS 24 INCHES (610 MM) LONG MINIMUM COMPLYING WITH 904.4.1 PROVIDED THAT THE REQUIRED CLEAR FLOOR OR GROUND SPACE IS
CENTERED ON THE ACCESSIBLE LENGTH OF THE COUNTER.
COUNTER TOP.
48 min m i n
24 min
COUNTER
PLAN
CL
904.4.1 PARALLEL APPROACH.
A PORTION OF THE COUNTER SURFACE THAT IS 36 INCHES (915 MM) LONG MINIMUM AND 36 INCHES (915 MM) HIGH MAXIMUM ABOVE THE FINISH FLOOR SHALL BE PROVIDED. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 305 SHALL BE POSITIONED FOR A PARALLEL APPROACH ADJACENT TO THE 36 INCH (915 MM) MINIMUM LENGTH OF
COUNTER.
EXCEPTION: WHERE THE PROVIDED COUNTER SURFACE IS LESS THAN 36 INCHES (915 MM) LONG, THE ENTIRE
COUNTER SURFACE SHALL BE 36 INCHES (915 MM) HIGH MAXIMUM ABOVE THE FINISH FLOOR.
GROUND.
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
LIMITED OFFICIAL USE
MARK DESCRIPTION DATE
t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
©2020 Bailey Edward Design Design Firm License No. 184-001962
NAME
STREET
CITY/STREET/ZIP
BUILDING NO.
OTHER
BUILDING NOs.
PROJECT
DESCRIPTION
PROJECT NO.
DRAWING TITLE
TYPE
FILE NAME
FLOOR NO.
DRAWN BY
CHECKED BY
DRAWING NO.
17005 - 020019 - 00
AM SHEET SIZE: 24 X 36
DATE: 09.24.20
SHEET OF
B U
I L D
I N
G P
J C
T
D R
A W
I N
G
SH
USDC & USBC TRANSACTION WINDOWS
(IN0096ZZ)
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST,
SOUTH BEND, IN 46601-2122
100% CD 10.28.2022
GENERAL SERVICES ADMINISTRATION
REGION 5 CHICAGO, IL
ADA ACCESSIBILITY STANDARDS
NTS
US. DISTRICT COURT
CLERK'S OFFICE
EXIT: CLEAR WIDTH = 3'-0"
EXIT CAPACITY = 180 OCCUPANTS
ACTUAL = 12 OCCUPANTS
TR
AV
EL
D
IS
TA
NC
E:
-F
EE
T
0-
FE
ET
NOTE: NO RAMP IN BUILDING.
WHEELCHAIR LIFT AVAILABLE AT NORTH WEST MAIN
ENTRANCE.
A SECOND WHEELCHAIR LIFT IS LOCATED AT THE NORTH
STEPS BETWEEN THE UPPER AND LOWER SECOND FLOORS
AC
CE
SS
IB
LE
T
RA
VE
L D
IS
TA
NC
E:
AP
PR
OX
. 7 0 F
EE
T
0-
FE
ET
EXIT: CLEAR WIDTH = 3'-0"
EXIT CAPACITY = 180 OCCUPANTS
ACTUAL = 12 OCCUPANTS
TOTAL = 23 OCCUPANTS
AREA N.I.C. PROJECT AREA
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
LIMITED OFFICIAL USE
MARK DESCRIPTION DATE
t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
©2020 Bailey Edward Design Design Firm License No. 184-001962
NAME
STREET
CITY/STREET/ZIP
BUILDING NO.
OTHER
BUILDING NOs.
PROJECT
DESCRIPTION
PROJECT NO.
DRAWING TITLE
TYPE
FILE NAME
FLOOR NO.
DRAWN BY
CHECKED BY
DRAWING NO.
17005 - 020019 - 00
AM SHEET SIZE: 24 X 36
DATE: 09.24.20
SHEET OF
B U
I L D
I N
G P
J C
T
D R
A W
I N
G
SH
USDC & USBC TRANSACTION WINDOWS
(IN0096ZZ)
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST,
SOUTH BEND, IN 46601-2122
100% CD 10.28.2022
GENERAL SERVICES ADMINISTRATION
REGION 5 CHICAGO, IL
1. EXISTING LIFE SAFETY INFORMATION SHOWN IS
FROM LIFE SAFETY DRAWINGS PROVIDED BY THE
OWNER. ALL CONTRACTORS SHALL REVIEW ANY
POSSIBLE RECENT REVISIONS TO THE OWNERS
LIFE SAFETY CRITERIA AND FIELD VERIFY
CONDITIONS OF RATINGS INDICATED PRIOR TO
COMMENCING THE WORK.
LIFE SAFETY GENERAL NOTES:
CODE PLAN LEGEND:
LINE OF TRAVEL FROM REMOTE
LOCATION TO EXIT
(NOT TO EXCEED 300-FT)
LINE OF ACCESSIBLE ROUTE
(NOT TO EXCEED 100-FT)
VERTICAL EGRESS
ROBERT GRANT FEDERAL BUILDING AND U.S. COURTHOUSE
204 SMAIN STREET. SOUTH BEND, IN 46601-2122
SCALE: 3/32"=1'-0" SCALE: 3/32" = 1'-0"
0 8' 16'
NORTHNORTH
1ST FLOOR N.T.S.
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST, SOUTH
BEND, IN 46601-2122
KEYPLAN
NFPA 101 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
BUSINESS AREAS 150 GROSS
ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 GROSS
US. DISTRICT COURT CLERK'S OFFICE
BUSINESS USE = 3,440 SQFT % 150 GROSS = 23
STORAGE USE = 124 SQFT % 300 GROSS = 0.41
US. DISTRICT COURT CLERK'S OFFICE: 2 MAIN EXIT PATHS / 1 EXIT PATHS
US. DISTRICT COURT CLERK'S OFFICE RECEPTION (NEW ENCLOSED SPACE):
1 MAIN EXIT / 1 EXIT PATH
CODE ANALYSIS:
NATIONAL FIRE PROTECTION ASSOCIATION: GROUP
BUSINESS (B)
STORAGE (S)
OCCUPANCY GROUP (B)
MAXIMUM OCCUPANCY LOAD WITH (1) EXIT = 50
MINIMUM NO. OF OCCUPANTS WITH (2) EXIT = 51 - 500
OCCUPANCY GROUP (S)
MAXIMUM OCCUPANCY LOAD WITH (1) EXIT = 30
MINIMUM NO. OF OCCUPANTS WITH (2) EXIT = 31 - 500
NORTHNORTH
NEW WALL
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME TO REMAIN
EXISTING EQUIPMENT
AREA N.I.C.
WINDOW TAG. SEE
SCHEDULE, SHEET A900
PARTITION TYPE TAG. SEE
SHEET G002
DOOR TAG. SEE
SCHEDULE, SHEET A900
ROOM #
ROOM NAME ROOM TAG. SEE
SCHEDULE, SHEET A901
NEW DOOR AND FRAME
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME TO
REMAIN
EXISTING TO BE DEMOLISHED
AREA N.I.C.
INDICATES KEYNOTE APPLICABLE TO
ENTIRE WORK AREA
EXISTING WALL TO BE REMOVED
ROOM #
ROOM NAME ROOM TAG
EXISTING DOOR AND FRAME TO BE
DEMOLISHED
AREA N.I.C.
PROJECT AREA
US. DISTRICT COURT
CLERK'S OFFICE
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
US. DISTRICT COURT
CLERK'S OFFICE
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
30 X 48 ADA CLEARANCE
A300
3'- 33 4"
1'- 4"
8"
2'-
1 4"
1 2"
9'-10"
3'- 93 4"
4'-10"
8.03
8.01 6.02
11.01
6.03
10.01
6.01
6.04 6.02
8.04
A600
11.02
A1004
US. DISTRICT COURT
CLERK'S OFFICE
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
US. DISTRICT COURT
CLERK'S OFFICE
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
3'- 93 4"
2.09
2.02
2.01
2.14
2.14 2.13
2.16
A1003
2.21
2.02
3'- 8"
2.13 2.17
2.172.18
2'- 8"
3'- 8"
8.01 9.02
6.01 8.046.04 6.02
6.05 8.02
1ST LEVEL PARTIAL NEW WORK FLOOR PLAN
US. DISTRICT COURT CLERK'S OFFICE RECEPTION DESK
SCALE: 3/8"=1'-0" SCALE: 3/8" = 1'-0"
0 2' 4'
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
LIMITED OFFICIAL USE
MARK DESCRIPTION DATE
t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
©2020 Bailey Edward Design Design Firm License No. 184-001962
NAME
STREET
CITY/STREET/ZIP
BUILDING NO.
OTHER
BUILDING NOs.
PROJECT
DESCRIPTION
PROJECT NO.
DRAWING TITLE
TYPE
FILE NAME
FLOOR NO.
DRAWN BY
CHECKED BY
DRAWING NO.
17005 - 020019 - 00
AM SHEET SIZE: 24 X 36
DATE: 09.24.20
SHEET OF
B U
I L D
I N
G P
J C
T
D R
A W
I N
G
SH
USDC & USBC TRANSACTION WINDOWS
(IN0096ZZ)
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST,
SOUTH BEND, IN 46601-2122
100% CD 10.28.2022
GENERAL SERVICES ADMINISTRATION
REGION 5 CHICAGO, IL
NORTHNORTH
1ST FLOOR N.T.S.
KEYPLAN
1ST LEVEL PARTIAL DEMO FLOOR PLAN
US. DISTRICT COURT CLERK'S OFFICE RECEPTION DESK
SCALE: 3/8"=1'-0" SCALE: 3/8" = 1'-0"
0 2' 4'
NORTH
NEW WORK PLAN GENERAL NOTES
6.01 NEW WOOD SECURITY DOOR WITH BREAK RESISTANT
TEMPERED GLAZING LIGHT AND FRAME
6.02 PROVIDE BLOCKING REINFORCEMENT UNDER
COUNTERTOP AS REQUIRED TO SUPPORT NEW
TEMPERED GLAZING WINDOW AND ALUMINUM FRAME
6.03 NEW COUNTERTOP CABLE PERFORATION AND
GROMMET
6.04 NEW ADA HEIGHT AT PLASTIC LAMINATE SERVICE
COUNTERTOP. 36” MAX HEIGHT AT COUNTERTOP
6.05 NEW GLAZING TRANSOM ABOVE NEW SECURITY DOOR
8.01 NEW BREAK RESISTANT TEMPERED GLAZING WINDOW,
FROM COUNTERTOP TO CEILING WITH ALUMINUM
FRAME AT BOTH ENDS
8.02 NEW SPEAKING PORTAL AT TRANSACTION WINDOW
8.04 NEW DOCUMENT TRAY DEPRESSED INTO PLASTIC
LAMINATE COUNTER, ADA HEIGHT, 36” MAX
9.02 NEW GYPSUM BOARD SOFFIT
10.01 NEW CARD READER AT DOOR FOR ACCESS CONTROL
11.01 COMPUTER STATION
11.02 CREDIT CARD MACHINE
KEYNOTES:
1. CONTRACTOR SHALL VISIT SITE AND BECOME FAMILIAR
WITH EXISTING CONDITIONS PRIOR TO COMMENCING
WORK. EXISTING CONDITIONS SHOWN ARE FROM
INFORMATION PROVIDED BY GOVERNMENT. VERIFY IN
FIELD ALL EXISTING CONDITIONS, PRIOR TO PROCEEDING
WITH THE WORK.
2. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY AND ALL
DISCREPANCIES BETWEEN CONTRACT DOCUMENTS AND
EXISTING CONDITIONS PRIOR TO PROCEEDING WITH
WORK.
3. PATCH AND PREPARE EXISTING WALLS AS NECESSARY
TO RECEIVE NEW FINISHES WHERE SCHEDULED.
4. ROOM LAYOUTS AND CONFIGURATIONS FOR AREAS
OUTSIDE OF CURRENT WORK ARE SHOWN FOR
REFERENCE ONLY.
LEGEND
2.01 PATCH AND REPAIR EXISTING WALL SURFACE TO
MATCH ADJACENT.COORDINATE WITH NEW
CONSTRUCTION.
2.02 REMOVE EXISTING WOOD DOOR AND FRAME. PATCH
ADJACENT WALL AND PREP FOR NEW DOOR.
2.09 REMOVE AND FILL EXISTING COUNTERTOP CABLE
PERFORATION. NEW PLASTIC LAMINATE TO MATCH
ADJACENT PLASTIC LAMINATE SURFACE. REMOVE
AND RELOCATE GROMMET. SEE NEW WORK FLOOR
PLAN FOR NEW GROMMET LOCATION.
2.13 MODIFY EXISTING PLASTIC LAMINATE COUNTERTOP
AND WOOD BASE CABINET AS REQUIRED PER ADA
REQUIREMENTS. REFER TO FLOOR PLAN.
2.14 MODIFY EXISTING PLASTIC LAMINATE COUNTERTOP
AND WOOD BASE CABINET AS REQUIRED FOR NEW
DOCUMENT TRAY DEPRESSED INTO COUNTER.
2.16 EXISTING COUNTERTOP AND COMPUTER STATIONS TO
REMAIN.
2.17 EXISTING PLASTIC LAMINATE COUNTERTOP AND
BELOW SHELVING TO REMAIN.
2.18 EXISTING SHELVING TO BE REMOVED.
2.21 EXISTING HISTORIC SPACES AND SURFACES
ADJACENT TO WORK AREA TO BE PROTECTED FROM
ANY DAMAGE FOR THE DURATION OF THE PROJECT.
SEE SPEC 01 35 10.
1. REMOVE AND LEGALLY DISPOSE OFF SITE THOSE ITEMS
INDICATED TO BE REMOVED. REMOVE AND DISPOSE OF
DEMOLITION DEBRIS DAILY, AFTER GOVERNMENT
OCCUPIED HOURS.
2. CONTRACTORS TO USE CARE WHEN PERFORMING WORK
ABOVE CEILINGS TO AVOID DAMAGE TO EXISTING UTILITIES
AND OTHER MATERIALS TO REMAIN.
3. ALL DEMOLITION TO BE DONE NEATLY AND WITHOUT
DAMAGE TO EXISTING CONSTRUCTION. PROTECT
CONSTRUCTION TO REMAIN. PROMPTLY REPAIR DAMAGES
CAUSED TO ADJACENT FACILITIES AT NO COST TO THE
GOVERNMENT. SEE SPECIFICATION SECTION 01 73 20
SELECTIVE DEMOLITION.
4. ERECT AND MAINTAIN DUST-PROOF PARTITIONS AND
CLOSURES AS REQUIRED TO PREVENT SPREAD OF DUST
OR FUMES.
5. THIS DRAWING IS PRIMARILY FOR ARCHITECTURAL
DEMOLITION SCOPE. REFER TO MECHANICAL, ELECTRICAL,
AND PLUMBING FOR ADDITIONAL DEMOLITION
REQUIREMENTS.
6. ALL CONTRACTORS EXPECTED TO RECYCLE
CONSTRUCTION WASTE AND DEMOLITION MATERIALS AND
TO SUBMIT TO GSA CERTIFICATES FOR ALL MATERIALS
DIVERTED FROM LANDFILL. CONTRACTORS ARE ALLOWED
TO BRING ADDITIONAL DUMPSTERS. ALL DEMOLITION
WASTE REMOVAL SHOULD BE COORDINATED WITH THE
PROPERTY MANAGER. SEE SPECIFICATION SECTION 01 74
19.
7. ALL CONTRACTORS ARE REQUIRED TO MAKE A SITE VISIT
TO VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING
BIDS.
8. THE CONTRACTOR IS REQUIRED TO FOLLOW ALL BUILDING
SPECIFIC WORK RESTRICTIONS- SEE SPECIFICATIONS
SECTION 01 14 00.
9. WHERE DEMOLITION OCCURS, REMOVE AND CAP UTILITIES
AT THEIR SOURCE UNLESS NOTED OTHERWISE.
10. PLANS ARE DIAGRAMMATIC AND PROVIDED TO SHOW
INTENT ONLY. UNLESS NOTED OTHERWISE ALL PARTITION
ASSEMBLIES INDICATED TO BE DEMOLISHED SHALL BE
DEMOLISHED COMPLETELY, INCLUDING FINISHES GYP. BD.,
METAL FRAMING, FASTENING DEVICES ETC.
11. AREA OF DEMOLITION/REMOVAL IN CORRIDOR,
CONTRACTOR SHALL REPAIR FLOORS, WALLS AND
FINISHED CEILINGS AS REQUIRED TO MATCH EXISTING AND
TO BE FLUSH AND SMOOTH WITH ADJACENT.
12. CONTRACTOR TO INSPECT ABOVE CEILING FOR
CONTINUITY OF PLENUM ENCLOSURE. NOTIFY ARCHITECT
OF ANY EXISTING DEFECTS /GAPS/ OPENINGS PRIOR TO
PROCEEDING
DEMOLITION GENERAL NOTES DEMOLITION KEYNOTES: LEGEND
NORTH
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST, SOUTH
BEND, IN 46601-2122
1ST LEVEL PARTIAL DEMO ELEVATION
US. DISTRICT COURT CLERK'S OFFICE
SCALE: 3/8"=1'-0" SCALE: 3/8" = 1'-0"
0 2' 4'
1ST LEVEL PARTIAL NEW ELEVATION
US. DISTRICT COURT CLERK'S OFFICE
SCALE: 3/8"=1'-0" SCALE: 3/8" = 1'-0"
0 2' 4'
ADA MOD. FROM EMPLOYEE SIDE ADA MOD. FROM EMPLOYEE SIDE
AREA NOT IN SCOPE OF WORK
EXISTING 2x2 LIGHT FIXTURE TO BE REMOVED;
REF. ELECTRICAL PLANS
EXISTING MECH. SUPPLY DIFFUSER TO BE
REMOVED; REF. MECHANICAL PLANS
EXISTING MECH. RETURN DIFFUSER TO BE
REMOVED; REF. MECHANICAL PLANS
INDICATES KEYNOTE APPLICABLE FOR ENTIRE
AREA
EXISTING SPRINKLER TO BE REMOVED
EXISTING FIRE ALARM TO BE REMOVED
EXISTING 2X2 ACOUSTICAL CEILING TILES AND
GRID TO REMAIN
EXISTING GYP BOARD CEILING TO BE REMOVED
EXISTING WALL TO REMAIN
EXISTING TO BE DEMOLISHED
EXISTING 2X2 ACOUSTICAL CEILING TILES AND
GRID TO BE REMOVED
EXISTING 2X2 LIGHT FIXTURE TO BE REMOVED;
REF. ELECTRICAL PLANS
EXISTING 2X4 LIGHT FIXTURE TO BE REMOVED;
REF. ELECTRICAL PLANS
EXISTING OCC SENSOR TO BE REMOVED
AREA NOT IN SCOPE OF WORK
NEW 2x2 LIGHT FIXTURE;
REF. ELECTRICAL PLANS
NEW MECH. SUPPLY DIFFUSER;
REF. MECHANICAL PLANS
NEW MECH. RETURN DIFFUSER;
REF. MECHANICAL PLANS
INDICATES KEYNOTE APPLICABLE FOR ENTIRE
AREA
NEW SPRINKLERS
NEW FIRE ALARM
NEW 2X2 ACOUSTICAL CEILING TILES AND GRID
EXISTING WALL TO REMAIN
NEW WALL
NEW 2X4 ACOUSTICAL CEILING TILES AND GRID
NEW GYP BOARD CEILING
NEW 2X2 SURFACE MOUNTED LIGHT FIXTURE;
REF. ELECTRICAL PLANS
NEW 2X4 SURFACE MOUNTED LIGHT FIXTURE;
REF. ELECTRICAL PLANS
NEW OCC SENSOR
AREA N.I.C.
PROJECT AREA
US. DISTRICT COURT
CLERK'S OFFICE
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
US. DISTRICT COURT
CLERK'S OFFICE
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
US. DISTRICT COURT
CLERK'S OFFICE
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
2.042.05
2.10
2.06
2.10
2.05
2.20
2.20
2.20
US. DISTRICT COURT
CLERK'S OFFICE
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
US. DISTRICT COURT
CLERK'S OFFICE
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
US. DISTRICT COURT
CLERK'S OFFICE
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
8'-0"
9'-0"
2'-0"
9.03
9.01 9.02
9.04
9.01
9.04
A600
2.20
2.20
2.20
1ST LEVEL PARTIAL NEW WORK RCP
US. DISTRICT COURT CLERK'S OFFICE RECEPTION DESK
SCALE: 3/8"=1'-0" SCALE: 3/8" = 1'-0"
0 2' 4'
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
LIMITED OFFICIAL USE
MARK DESCRIPTION DATE
t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
©2020 Bailey Edward Design Design Firm License No. 184-001962
NAME
STREET
CITY/STREET/ZIP
BUILDING NO.
OTHER
BUILDING NOs.
PROJECT
DESCRIPTION
PROJECT NO.
DRAWING TITLE
TYPE
FILE NAME
FLOOR NO.
DRAWN BY
CHECKED BY
DRAWING NO.
17005 - 020019 - 00
AM SHEET SIZE: 24 X 36
DATE: 09.24.20
SHEET OF
B U
I L D
I N
G P
J C
T
D R
A W
I N
G
SH
USDC & USBC TRANSACTION WINDOWS
(IN0096ZZ)
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST,
SOUTH BEND, IN 46601-2122
100% CD 10.28.2022
GENERAL SERVICES ADMINISTRATION
REGION 5 CHICAGO, IL
1ST LEVEL PARTIAL DEMO RCP
US. DISTRICT COURT CLERK'S OFFICE RECEPTION DESK
SCALE: 3/8"=1'-0" SCALE: 3/8" = 1'-0"
0 2' 4' 8'
RCP GENERAL NOTES KEYNOTES:
1. CONTRACTOR SHALL VISIT THE SITE AND BECOME
FAMILIAR WITH THE EXISTING CONDITIONS PRIOR TO
COMMENCING THE WORK. EXISTING CONDITIONS SHOWN
ARE FROM INFORMATION PROVIDED BY THE
GOVERNMENT. VERIFY IN FIELD ALL EXISTING
CONDITIONS, DIMENSIONS, ELEVATION HEIGHTS,
CONSTRUCTION AND BUILDING SYSTEMS PRIOR TO
PROCEEDING WITH THE WORK.
2. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY
AND ALL DISCREPANCIES BETWEEN THE CONTRACT
DOCUMENTS AND EXISTING CONDITIONS PRIOR TO
PROCEEDING WITH THE WORK.
3. ROOM LAYOUTS AND CONFIGURATIONS FOR AREAS
OUTSIDE OF THE CURRENT WORK ARE SHOWN FOR
REFERENCE ONLY. EXISTING CONSTRUCTION IS BASED
UPON LIMITED SURVEYS BY THE ARCHITECT AND
INFORMATION PROVIDED BY THE GOVERNMENT. FIELD
VERIFICATION PRIOR TO COMMENCEMENT OF
CONSTRUCTION IS REQUIRED.
RCP LEGEND
2.04 EXISTING ACT CEILING TILES TO BE REMOVED
2.05 EXISTING LIGHT FIXTURES TO BE REMOVED AND
RELOCATED AS REQUIRED
2.06 EXISTING CEILING ELEMENTS TO BE REMOVED. FIRE
ALARMS, SPRINKLERS, OCC SENSORS, ETC. SEE
MECH.
2.10 REMOVE AND RELOCATE MECHANICAL SYSTEMS. SEE
MECH DRAWINGS
2.20 EXISTING LEAD PAINT FOUND: GREEN PAINT ON
CEILING COLUMNS ABOVE DROP CEILING, CREAM
PAINT ON THE CEILING AND PLASTER WALLS ABOVE
DROP CEILING AND BEHIND DRYWALL, WHITE PAINT
ON EXPOSED CEILING OF THE BASEMENT.
COORDINATE INSTALLATION WITH SPEC 02 83 00
LEAD-BASED PAINT MITIGATION PER AUGUST MACK
ENVIRONMENTAL SCOPE OF WORK
1. REMOVE AND LEGALLY DISPOSE OFF SITE THOSE ITEMS
INDICATED TO BE REMOVED. REMOVE AND DISPOSE OF
DEMOLITION DEBRIS DAILY, AFTER GOVERNMENT
OCCUPIED HOURS.
2. CONTRACTORS TO USE CARE WHEN PERFORMING WORK
ABOVE CEILINGS TO AVOID DAMAGE TO EXISTING UTILITIES
AND OTHER MATERIALS TO REMAIN.
3. ALL DEMOLITION TO BE DONE NEATLY AND WITHOUT
DAMAGE TO EXISTING CONSTRUCTION. PROTECT
CONSTRUCTION TO REMAIN. PROMPTLY REPAIR DAMAGES
CAUSED TO ADJACENT FACILITIES AT NO COST TO THE
GOVERNMENT. SEE SPECIFICATION SECTION 01 73 20
SELECTIVE DEMOLITION.
4. ERECT AND MAINTAIN DUST-PROOF PARTITIONS AND
CLOSURES AS REQUIRED TO PREVENT SPREAD OF DUST
OR FUMES.
5. THIS DRAWING IS PRIMARILY FOR ARCHITECTURAL
DEMOLITION SCOPE. REFER TO MECHANICAL, ELECTRICAL,
AND PLUMBING FOR ADDITIONAL DEMOLITION
REQUIREMENTS.
6. ALL CONTRACTORS EXPECTED TO RECYCLE
CONSTRUCTION WASTE AND DEMOLITION MATERIALS AND
TO SUBMIT TO GSA CERTIFICATES FOR ALL MATERIALS
DIVERTED FROM LANDFILL. CONTRACTORS ARE ALLOWED
TO BRING ADDITIONAL DUMPSTERS. ALL DEMOLITION
WASTE REMOVAL SHOULD BE COORDINATED WITH THE
PROPERTY MANAGER. SEE SPECIFICATION SECTION 01 74
19.
7. ALL CONTRACTORS ARE REQUIRED TO MAKE A SITE VISIT
TO VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING
BIDS.
8. THE CONTRACTOR IS REQUIRED TO FOLLOW ALL BUILDING
SPECIFIC WORK RESTRICTIONS- SEE SPECIFICATIONS
SECTION 01 14 00.
9. WHERE DEMOLITION OCCURS, REMOVE AND CAP UTILITIES
AT THEIR SOURCE UNLESS NOTED OTHERWISE.
10. PLANS ARE DIAGRAMMATIC AND PROVIDED TO SHOW
INTENT ONLY. UNLESS NOTED OTHERWISE ALL PARTITION
ASSEMBLIES INDICATED TO BE DEMOLISHED SHALL BE
DEMOLISHED COMPLETELY, INCLUDING FINISHES GYP. BD.,
METAL FRAMING, FASTENING DEVICES ETC.
11. AREA OF DEMOLITION/REMOVAL IN CORRIDOR,
CONTRACTOR SHALL REPAIR FLOORS, WALLS AND
FINISHED CEILINGS AS REQUIRED TO MATCH EXISTING AND
TO BE FLUSH AND SMOOTH WITH ADJACENT.
12. CONTRACTOR TO INSPECT ABOVE CEILING FOR
CONTINUITY OF PLENUM ENCLOSURE. NOTIFY ARCHITECT
OF ANY EXISTING DEFECTS /GAPS/ OPENINGS PRIOR TO
PROCEEDING
RCP DEMOLITION GENERAL NOTES
DEMOLITION KEYNOTES:
RCP LEGEND
2.20 EXISTING LEAD PAINT FOUND: GREEN PAINT ON
CEILING COLUMNS ABOVE DROP CEILING, CREAM PAINT
ON THE CEILING AND PLASTER WALLS ABOVE DROP
CEILING AND BEHIND DRYWALL, WHITE PAINT ON
EXPOSED CEILING OF THE BASEMENT. COORDINATE
INSTALLATION WITH SPEC 02 83 00 LEAD-BASED PAINT
MITIGATION PER AUGUST MACK ENVIRONMENTAL
SCOPE OF WORK
9.01 INSTALL NEW ACT CEILING TILES AS REQUIRED.
REINSTALL SALVAGED ACT AS REQUIRED UPON
MECHANICAL SCOPE COMPLETION
9.02 NEW GYPSUM BOARD SOFFIT
9.03 REINSTALL SALVAGED LIGHT FIXTURE IN NEW
LOCATION
9.04 NEW LIGHT FIXTURE
NORTH NORTH
NORTHNORTH
1ST FLOOR N.T.S.
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST, SOUTH
BEND, IN 46601-2122
KEYPLAN
AREA N.I.C.
PROJECT AREA
NEW WALL
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME TO REMAIN
EXISTING EQUIPMENT
AREA N.I.C.
WINDOW TAG. SEE
SCHEDULE, SHEET A900
PARTITION TYPE TAG. SEE
SHEET G002
# DOOR TAG. SEE
SCHEDULE, SHEET A900
ROOM #
ROOM NAME ROOM TAG. SEE
SCHEDULE, SHEET A901
NEW DOOR AND FRAME
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME TO
REMAIN
EXISTING TO BE DEMOLISHED
AREA N.I.C.
INDICATES KEYNOTE APPLICABLE TO
ENTIRE WORK AREA
EXISTING WALL TO BE REMOVED
ROOM #
ROOM NAME ROOM TAG
EXISTING DOOR AND FRAME TO BE
DEMOLISHED
ENTRANCE
SECURITY AREA
ENTRANCE
SECURITY AREA
ENTRANCE
SECURITY AREA
3'- 2 1 2"
1'-01 2"
10.0209.11
A112
ENTRANCE
SECURITY AREA
ENTRANCE
SECURITY AREA
ENTRANCE
SECURITY AREA
2.11
2.21
10.02
3 8"
36"
49 12"
36 12"
1ST LEVEL PARTIAL NEW WORK FLOOR PLAN
ENTRY TURNSTILE
SCALE: 3/8"=1'-0" SCALE: 3/8" = 1'-0"
0 2' 4'
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
LIMITED OFFICIAL USE
MARK DESCRIPTION DATE
t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
©2020 Bailey Edward Design Design Firm License No. 184-001962
NAME
STREET
CITY/STREET/ZIP
BUILDING NO.
OTHER
BUILDING NOs.
PROJECT
DESCRIPTION
PROJECT NO.
DRAWING TITLE
TYPE
FILE NAME
FLOOR NO.
DRAWN BY
CHECKED BY
DRAWING NO.
17005 - 020019 - 00
AM SHEET SIZE: 24 X 36
DATE: 09.24.20
SHEET OF
B U
I L D
I N
G P
J C
T
D R
A W
I N
G
SH
USDC & USBC TRANSACTION WINDOWS
(IN0096ZZ)
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST,
SOUTH BEND, IN 46601-2122
100% CD 10.28.2022
GENERAL SERVICES ADMINISTRATION
REGION 5 CHICAGO, IL
1ST LEVEL PARTIAL DEMO FLOOR PLAN
ENTRY TURNSTILE
SCALE: 3/8"=1'-0" SCALE: 3/8" = 1'-0"
0 2' 4' 8'
NORTH
NORTHNORTH
1ST FLOOR N.T.S.
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST, SOUTH
BEND, IN 46601-2122
KEYPLAN
NEW WORK PLAN GENERAL NOTES
9.11 PROVIDE BARRIER TO MATCH EXISTING
10.02 INSTALL NEW GLASS TURNSTILE WITH CARD READER
ACCESS. REFER TO ELECTRICAL DRAWINGS FOR
POWER AND DATA REQUIREMENTS
KEYNOTES:
1. CONTRACTOR SHALL VISIT SITE AND BECOME FAMILIAR
WITH EXISTING CONDITIONS PRIOR TO COMMENCING
WORK. EXISTING CONDITIONS SHOWN ARE FROM
INFORMATION PROVIDED BY GOVERNMENT. VERIFY IN
FIELD ALL EXISTING CONDITIONS, PRIOR TO PROCEEDING
WITH THE WORK.
2. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY AND ALL
DISCREPANCIES BETWEEN CONTRACT DOCUMENTS AND
EXISTING CONDITIONS PRIOR TO PROCEEDING WITH
WORK.
3. PATCH AND PREPARE EXISTING WALLS AS NECESSARY
TO RECEIVE NEW FINISHES WHERE SCHEDULED.
4. ROOM LAYOUTS AND CONFIGURATIONS FOR AREAS
OUTSIDE OF CURRENT WORK ARE SHOWN FOR
REFERENCE ONLY.
5. APPLY NEW FINISHES TO EXISTING WALL AND CEILING
MOUNTED COVER PLATES, ITEMS, ETC, LOCATED ON
EXISTING SURFACES SCHEDULED TO BE REFINISHED.
EXISTING ITEMS THAT ARE NOT REMOVABLE SHALL BE
CAREFULLY TAPED, OR OTHERWISE COVERED DURING
REFINISHING.
6. CEILING HEIGHT IS TO BE SET AS HIGH AS POSSIBLE,
CONSIDERING CLEARANCE FOR LIGHTING AND HVAC
APPROXIMATELY 9'-0" MIN.
7. ALL REQUIRED OPENINGS IN PERIMETER DEMISING
PARTITIONS SEPARATING NEW GAO OFFICES FROM
ADJACENT TENANTS OR PUBLIC CORRIDOR SHALL BE
KEPT AT LESS THAN A MAN-PASSABLE AREA - (96 SQUARE
INCHES). ANY LARGER OPENINGS SHALL BE HARDENED
WITH THE INSTALLATION OF STEEL SECURITY MAN BARS
8. SEE SHEET G002 FOR PARTITION TYPES.
LEGEND
2.11 REMOVE AND REPLACE EXISTING GLASS TURNSTILE
2.21 EXISTING HISTORIC SPACES AND SURFACES
ADJACENT TO WORK AREA TO BE PROTECTED FROM
ANY DAMAGE FOR THE DURATION OF THE PROJECT.
SEE SPEC 01 35 10
1. REMOVE AND LEGALLY DISPOSE OFF SITE THOSE ITEMS
INDICATED TO BE REMOVED. REMOVE AND DISPOSE OF
DEMOLITION DEBRIS DAILY, AFTER GOVERNMENT
OCCUPIED HOURS.
2. CONTRACTORS TO USE CARE WHEN PERFORMING WORK
ABOVE CEILINGS TO AVOID DAMAGE TO EXISTING UTILITIES
AND OTHER MATERIALS TO REMAIN.
3. ALL DEMOLITION TO BE DONE NEATLY AND WITHOUT
DAMAGE TO EXISTING CONSTRUCTION. PROTECT
CONSTRUCTION TO REMAIN. PROMPTLY REPAIR DAMAGES
CAUSED TO ADJACENT FACILITIES AT NO COST TO THE
GOVERNMENT. SEE SPECIFICATION SECTION 01 73 20
SELECTIVE DEMOLITION.
4. ERECT AND MAINTAIN DUST-PROOF PARTITIONS AND
CLOSURES AS REQUIRED TO PREVENT SPREAD OF DUST
OR FUMES.
5. THIS DRAWING IS PRIMARILY FOR ARCHITECTURAL
DEMOLITION SCOPE. REFER TO MECHANICAL, ELECTRICAL,
AND PLUMBING FOR ADDITIONAL DEMOLITION
REQUIREMENTS.
6. ALL CONTRACTORS EXPECTED TO RECYCLE
CONSTRUCTION WASTE AND DEMOLITION MATERIALS AND
TO SUBMIT TO GSA CERTIFICATES FOR ALL MATERIALS
DIVERTED FROM LANDFILL. CONTRACTORS ARE ALLOWED
TO BRING ADDITIONAL DUMPSTERS. ALL DEMOLITION
WASTE REMOVAL SHOULD BE COORDINATED WITH THE
PROPERTY MANAGER. SEE SPECIFICATION SECTION 01 74
19.
7. ALL CONTRACTORS ARE REQUIRED TO MAKE A SITE VISIT
TO VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING
BIDS.
8. THE CONTRACTOR IS REQUIRED TO FOLLOW ALL BUILDING
SPECIFIC WORK RESTRICTIONS- SEE SPECIFICATIONS
SECTION 01 14 00.
9. WHERE DEMOLITION OCCURS, REMOVE AND CAP UTILITIES
AT THEIR SOURCE UNLESS NOTED OTHERWISE.
10. PLANS ARE DIAGRAMMATIC AND PROVIDED TO SHOW
INTENT ONLY. UNLESS NOTED OTHERWISE ALL PARTITION
ASSEMBLIES INDICATED TO BE DEMOLISHED SHALL BE
DEMOLISHED COMPLETELY, INCLUDING FINISHES GYP. BD.,
METAL FRAMING, FASTENING DEVICES ETC.
11. AREA OF DEMOLITION/REMOVAL IN CORRIDOR,
CONTRACTOR SHALL REPAIR FLOORS, WALLS AND
FINISHED CEILINGS AS REQUIRED TO MATCH EXISTING AND
TO BE FLUSH AND SMOOTH WITH ADJACENT.
12. CONTRACTOR TO INSPECT ABOVE CEILING FOR
CONTINUITY OF PLENUM ENCLOSURE. NOTIFY ARCHITECT
OF ANY EXISTING DEFECTS /GAPS/ OPENINGS PRIOR TO
PROCEEDING
DEMOLITION GENERAL NOTES
DEMOLITION KEYNOTES:
LEGEND
NORTH
NEW TURNSTILE ENLARGED PLAN & ELEVATION
MODEL: WINGLOCK SWING 940, BOON EDAM
SCALE: 1"=1'-0" SCALE: 1" = 1'-0"
0 6" 1' 2'
2'- 8"
5'- 4"
1'- 0"
9.02
6.01
8.02
10.018.036.04
6.05
3'- 8"
4'- 4"
1'- 0"
8.028.01 9.02
11.018.03
9.13
3'- 8"
4'- 4"
1'- 0"
9.02
8.01
SCALE: 3/8" = 1'-0"
0 2' 4'
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
LIMITED OFFICIAL USE
MARK DESCRIPTION DATE
t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
©2020 Bailey Edward Design Design Firm License No. 184-001962
NAME
STREET
CITY/STREET/ZIP
BUILDING NO.
OTHER
BUILDING NOs.
PROJECT
DESCRIPTION
PROJECT NO.
DRAWING TITLE
TYPE
FILE NAME
FLOOR NO.
DRAWN BY
CHECKED BY
DRAWING NO.
17005 - 020019 - 00
AM SHEET SIZE: 24 X 36
DATE: 09.24.20
SHEET OF
B U
I L D
I N
G P
J C
T
D R
A W
I N
G
SH
USDC & USBC TRANSACTION WINDOWS
(IN0096ZZ)
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST,
SOUTH BEND, IN 46601-2122
100% CD 10.28.2022
GENERAL SERVICES ADMINISTRATION
REGION 5 CHICAGO, IL
6.01 NEW WOOD SECURITY DOOR WITH BREAK RESISTANT
TEMPERED GLAZING LIGHT AND FRAME
6.04 NEW ADA HEIGHT AT PLASTIC LAMINATE SERVICE
COUNTERTOP. 36” MAX HEIGHT AT COUNTERTOP
6.05 NEW GLAZING TRANSOM ABOVE NEW SECURITY DOOR
8.01 NEW BREAK RESISTANT TEMPERED GLAZING WINDOW,
FROM COUNTERTOP TO CEILING WITH ALUMINUM
FRAME AT BOTH ENDS
8.02 NEW SPEAKING PORTAL AT TRANSACTION WINDOW
8.03 NEW DOCUMENT TRAY DEPRESSED INTO PLASTIC
LAMINATE COUNTER
9.02 NEW GYPSUM BOARD SOFFIT
9.13 NEW VINYL DECAL FOR U.S. DISTRICT COURT CLERK'S
OFFICES. GRAPHIC, SIZE AND LOCATION TO BE
COORDINATED WITH GSA
10.01 NEW CARD READER AT DOOR FOR ACCESS CONTROL
11.01 COMPUTER STATION
KEYNOTES:
1ST LEVEL US. DISTRICT COURT CLERK'S
OFFICE RECEPTION DESK INTERIOR ELEVATION
SCALE: 3/8"=1'-0" 2
1ST LEVEL US. DISTRICT COURT CLERK'S
OFFICE RECEPTION DESK INTERIOR ELEVATION
SCALE: 3/8"=1'-0" 1
1ST LEVEL US. DISTRICT COURT CLERK'S
OFFICE RECEPTION DESK INTERIOR ELEVATION
SCALE: 3/8"=1'-0"
9' - 0"
3'- 8"
2'- 8"
8.02
8.01
9.02
8.04
6.02
6.04
8' - 0"
4'- 4"
2.20
A600
TYP.
9.019.01
6.06
A600
TYP.
05.0205.02
05.01 09.01
09.10
09.09
09.12
06.06
08.01
06.04
08.04
06.02
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
LIMITED OFFICIAL USE
MARK DESCRIPTION DATE
t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
©2020 Bailey Edward Design Design Firm License No. 184-001962
NAME
STREET
CITY/STREET/ZIP
BUILDING NO.
OTHER
BUILDING NOs.
PROJECT
DESCRIPTION
PROJECT NO.
DRAWING TITLE
TYPE
FILE NAME
FLOOR NO.
DRAWN BY
CHECKED BY
DRAWING NO.
17005 - 020019 - 00
AM SHEET SIZE: 24 X 36
DATE: 09.24.20
SHEET OF
B U
I L D
I N
G P
J C
T
D R
A W
I N
G
SH
USDC & USBC TRANSACTION WINDOWS
(IN0096ZZ)
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST,
SOUTH BEND, IN 46601-2122
100% CD 10.28.2022
GENERAL SERVICES ADMINISTRATION
REGION 5 CHICAGO, IL
SCALE: 1" = 1'-0"
0 6" 1' 2'
1ST LEVEL PARTIAL SECTION
US. D.C. OFFICE RECEPTION DESK
SCALE: 1"=1'-0"
2.20 EXISTING LEAD PAINT FOUND: GREEN PAINT ON CEILING
COLUMNS ABOVE DROP CEILING, CREAM PAINT ON THE
CEILING AND PLASTER WALLS ABOVE DROP CEILING AND
BEHIND DRYWALL, WHITE PAINT ON EXPOSED CEILING OF THE
BASEMENT. COORDINATE INSTALLATION WITH SPEC 02 83 00
LEAD-BASED PAINT MITIGATION PER AUGUST MACK
ENVIRONMENTAL SCOPE OF WORK
5.01 5/8” GWB ON 3 5/8” MTL STUDS @ 16” OC MAX
5.02 KICKER BRACING AS REQUIRED AT BOTH SIDES
6.02 PROVIDE BLOCKING REINFORCEMENT UNDER COUNTERTOP
AS REQUIRED TO SUPPORT NEW TEMPERED GLAZING
WINDOW AND ALUMINUM FRAME
6.04 NEW ADA HEIGHT AT PLASTIC LAMINATE SERVICE
COUNTERTOP. 36” MAX HEIGHT AT COUNTERTOP
6.06 NEW VENEER CORE PLYWOOD PIECE AT SIDE OF ADA
COUNTERTOP HEIGHT CHANGE. FINISH TO MATCH ADJACENT
CASEWORK
8.01 NEW BREAK RESISTANT TEMPERED GLAZING WINDOW, FROM
COUNTERTOP TO CEILING WITH ALUMINUM FRAME AT BOTH
ENDS
8.02 NEW SPEAKING PORTAL AT TRANSACTION WINDOW
8.04 NEW DOCUMENT TRAY DEPRESSED INTO PLASTIC LAMINATE
COUNTER, ADA HEIGHT, 36” MAX
9.01 INSTALL NEW ACT CEILING TILES AS REQUIRED. REINSTALL
SALVAGED ACT AS REQUIRED UPON MECHANICAL SCOPE
COMPLETION
9.02 NEW GYPSUM BOARD SOFFIT
9.09 5/8” GYPSUM BOARD
9.10 SUSPENSION CABLE
9.12 PLASTIC LAMINATE CLAD ON EDGE FINISH OF COUNTERTOP.
MATCH COUNTERTOP COLOR
KEYNOTES:
TYP. NEW SOFFIT & ACT
CONNECTION WITH ABOVE SLAB DETAIL
SCALE: 1"=1'-0" 2
TYP. SIDE PANEL AT ADA HEIGHT CHANGE
SECTION OF COUNTER DETAIL
SCALE: 1"=1'-0"
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
21.01
02.03
02.03
02.03
US. DISTRICT COURT
CLERK'S OFFICE
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
F
02.01
02.02
02.03
02.03
02.03
FP130
FIRE PROTECTION PLANS
FP130
GREAT LAKES REGION 5
PROPERTY OF THE
UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
DO NOT REMOVE THIS NOTICE.
PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
LIMITED OFFICIAL USE
MARK DESCRIPTION DATE
t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
©2022 Bailey Edward Design Design Firm License No. 184-001962
GENERAL SERVICE ADMINISTRATION
REGION 5 CHICAGO, IL
NAME
STREET
CITY/STREET/ZIP
BUILDING NO.
OTHER
BUILDING NOs.
PROJECT
DESCRIPTION
PROJECT NO.
DRAWING TITLE
TYPE
FILE NAME
FLOOR NO.
DRAWN BY
CHECKED BY
DRAWING NO.
17005 - 020019 - 00
JPB SHEET SIZE: 24 X 36
DATE: 10.28.22
SHEET OF
BU
ILD
IN
G
PJ
CT
DR
AW
IN
G
KWL
USDC & USBC TRANSACTION WINDOWS
(IN0096ZZ)
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST, SOUTH
BEND, IN 46601-2122
100% CD 10.28.22
PE19500200
STATE OF
PROFESS I ONA L ENG I N
EE
R
I N D I A N A
KE
NT
W. LOCKE, JR.
signature date 10/28/2022 license expires on 07-31-2023
FIRE PROTECTION
1ST LEVEL PARTIAL NEW WORK FIRE PROTECTION PLAN
DISTRICT COURT OFFICE RECEPTION DESK
SCALE: 3/8"=1'-0" SCALE: 3/8" = 1'-0"
0 2' 4'
NORTHNORTH
1ST FLOOR N.T.S.
1ST LEVEL PARTIAL DEMO FIRE PROTECTION PLAN
DISTRICT COURT OFFICE RECEPTION DESK
SCALE: 3/8"=1'-0" SCALE: 3/8" = 1'-0"
0 2' 4'
NORTH NORTH
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST, SOUTH
BEND, IN 46601-2122
KEYPLAN
02.01 REMOVE SPRINKLER HEAD.
02.02 EXISTING SPRINKLER MAIN TO REMAIN.
02.03 EXISTING LEAD PAINT FOUND: GREEN PAINT ON CEILING
COLUMNS ABOVE DROP CEILING, CREAM PAINT ON THE
CEILING AND PLASTER WALLS ABOVE DROP CEILING AND
BEHIND DRYWALL, WHITE PAINT ON EXPOSED CEILING OF
THE BASEMENT. COORDINATE INSTALLATION WITH SPEC
02 83 00 LEAD-BASED PAINT MITIGATION PER AUGUST MACK
ENVIRONMENTAL SCOPE OF WORK.
21.01 PROVIDE NEW SPRINKLER HEAD IN NEW CEILING.
1. ALL DUCT SIZES NOTED ON DRAWINGS REFER TO ACTUAL AIRWAY SIZES (SOUND
LINING AND/OR INSULATION IS NOT INCLUDED).
2. ALL DUCT COVERINGS AND LININGS SHALL HAVE A FLAME SPREAD RATINGS NOT
TO EXCEED 25 AND A SMOKE DEVELOPMENT RATING NOT MORE THAN 50.
3. COORDINATE ALL FINAL LOCATIONS OF SUPPLY AIR DIFFUSERS, RELIEF AIR
GRILLES, THERMOSTATS, SENSORS, ETC. WITH ARCHITECT AND
ARCHITECTURAL REFLECTED CEILING PLANS.
4. MECHANICAL CONTRACTOR TO COORDINATE WITH ALL OTHER TRADES
INVOLVED, ALL WORK WHICH IS IN THE CEILING SPACE AS INDICATED ON THE
DRAWINGS WITHOUT CONFLICT AND TO REVISE HIS WORK TO AVOID CONFLICTS
AND OBSTRUCTIONS AS NECESSARY AND AS REQUIRED.
5. ALL DUCTS PENETRATING FULL HEIGHT WALLS ABOVE CEILING SHALL BE
SEALED TO WITHIN 1/8" OF DUCT WITH WALL MATERIAL ON EACH SIDE OF WALL.
6. COORDINATE EXACT LOCATIONS OF TEMPERATURE SENSORS FOR HVAC
EQUIPMENT WITH FINAL INTERIOR DESIGN/ARCHITECTURAL DRAWINGS.
7. ALL ROOM THERMOSTATS SHALL HAVE CENTERS ALIGNED WITH LIGHT
SWITCHES.
8. DUCT CONSTRUCTION AND INSTALLATION SHALL COMPLY WITH LATEST SMACNA
STANDARDS. DUCTS SHALL BE CONSTRUCTED OF GALVANIZED SHEET STEEL.
9. PROVIDE 1" THICK FLEXIBLE ELASTOMERIC SOUND LINING FOR Z DUCT
TRANSFER DUCTS. FIBERGLASS LINER IS NOT ALLOWED PER GSA P100.
PROVIDE 1" THICK FIBERGLASS WRAP FOR ALL SUPPLY DUCTWORK.
10. ALL CONSTRUCTION DOCUMENTS, INSTALLATION MANUALS, MANUFACTURERS
CATALOG CUTSHEETS ARE TO BE SUBMITTED TO THE GSA AND LANDLORD. ALL
MATERIALS AND EQUIPMENT ARE TO BE LISTED AND LABELED AND SUITABLE
FOR USE.
11. EXISTING HVAC SYSTEMS SHALL BE REBALANCED FOR NEW CAPACITIES
ACCORDING TO HVAC PLANS AND SCHEDULES
12. LOCATIONS OF EXISTING DUCT WORK, PIPING, THERMOSTATS, DIFFUSERS, ETC.
SHOWN ON THIS DRAWING ARE BASED ON PREVIOUS DESIGN WORKING
DRAWINGS AND DO NOT NECESSARILY INDICATE THE ACTUAL LOCATIONS.
REVISE NEW DUCTWORK, PIPING, ETC., AS REQUIRED TO CONNECT TO EXISTING
WORK. CONTRACTOR TO VERIFY TO VERIFY AND COVER NECESSARY WORK IN
BID.
13. FIRE CAULK ALL DUCT SYSTEMS WHICH PENETRATE THROUGH FIRE
RESISTANCE RATED WALLS, PARTITIONS, FLOORS, OR CEILINGS TO MAINTAIN 1
HOUR RATING.
14. HVAC SYSTEMS SHALL BE BALANCED ACCORDING TO HVAC PLANS AND
SCHEDULES. SUBMIT WRITTEN REPORT TO GSA. BALANCING CONTRACTOR TO
DETERMINE STATIC PRESSURE SETPOINT OF EXISTING DUCT SYSTEM. INDICATE
SPEED OF FAN DURING SYSTEM BALANCE. PRETEST EXISTING DIFFUSERS
CONNECTED TO RELOCATED VAV BOX.
15. INSTALL ALL EQUIPMENT AND ASSOCIATED MATERIALS AND ACCESSORIES PER
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
16. COORDINATE LOCATION OF NEW VAV BOX PENETRATION WITH EXISTING WALL
CONSTRUCTION. PROVIDE LINTELS AT BLOCK WALLS. PROVIDE OFFSETS TO
AVOID EXISTING TRADES, WALL STRUCTURE, AND BUILDING STRUCTURE.
17. EXTEND EXISTING SCHNEIDER ELECTRIC DDC SYSTEM TO ACCOMMODATE
CONNECTION OF NEW EQUIPMENT. GRAPHICS AND SEQUENCE FOR NEW
EQUIPMENT TO MATCH EXISTING. COORDINATE WITH PROPERTY MANAGEMENT.
18. THE CONTRACTOR SHALL BE FAMILIAR WITH GSA SECURITY CLEARANCE AND
OBTAINING SAID CLEARANCE. COSTS TO OBTAIN CLEARANCES FOR PERSONNEL
WORKING ON SITE ARE THE RESPONSIBILITY OF THE CONTRACTOR.
UNIT HEATERUH
WATER HEATERWH
WMS WIRE MESH SCREEN
VPT VELOCITY PRESSURE TRANS
CENTRAL CONTROL PANELCCP
THOUSANDS BRITISH THERMAL
UNITS PER HOUR
M
T
VAV
NEW CONNECTION
FULL PORT BALL VALVE
MOTOR OPERATED DAMPER OR VALVE
ROOM THERMOSTAT (S-SENSOR)
MBH
ROOMRM
DWG DRAWING
DIFF DIFFUSER
ACCESS DOOR
AIR HANDLING SYSTEM
AMPERE
BOTTOM OF DUCT
BRITISH THERMAL UNIT
BRITISH THERMAL UNITS PER HOUR
COOLING COIL
CUBIC FEET PER MINUTE
CONCRETE
HEATING COIL
HORSEPOWER
HEATING
INSIDE DIAMETER
INCH
WATT
WITH
WET BULB TEMPERATURE
WATER COLUMN
INSULATION
KILOWATT
KILOWATT HOUR
LEAVING AIR TEMPERATURE
LINED DUCT
LEAVING WATER TEMPERATURE
MIXED AIR TEMPERATURE
MANUAL
MAXIMUM
MINIMUM
NOISE CRITERIA
NORMALLY CLOSED
NOT IN CONTRACT
NECK
NUMBER
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR INTAKE
SINGLE PHASE
THREE PHASE
PRESSURE
POUNDS PER SQUARE INCH ABSOLUTE
POUNDS PER SQUARE INCH GAUGE
RETURN AIR
REGISTER
RETURN
TYPICAL
REQUIRED
RELATIVE HUMIDITY
REVOLUTIONS PER MINUTE
ROOF OPENING
SUPPLY FAN
SCREWED
SPECIFICATION
STATIC PRESSURE
SPLITTER DAMPER
STANDARD
TOTAL STATIC PRESSURE
VALVE
VARIABLE AIR VOLUME
VOLUME DAMPER
VELOCITY
HERTZ
GRILLE
GALLONS PER MINUTE
GAGE OR GAUGE
FOOT
FEET PER MINUTE
FLEXIBLE
FLOOR
FAN COIL UNIT
EXHAUST
ENTERING WATER TEMPERATURE
EXISTING TO REMAIN
ELEVATION
EFFICIENCY
EXHAUST FAN
DIAMETER
ENTERING AIR TEMPERATURE
DEFLECTION
DRY BULB TEMPERATURE
DECIBEL
CEILING REGISTER
CENTER LINE
CEILING
COMPRESSION TANK
Z
HWR
HWS
Y-TYPE STRAINER WITH CLEANOUT PLUG
TWO-WAY VALVE
UNION
PRESSURE REDUCING VALVE
PRESSURE GAUGE ASSEMBLY W/SNUBBER
PRESSURE GAUGE ASSEMBLY
FLOW IN THE DIRECTION OF ARROW
FLEXIBLE CONNECTION
CAP
AUTO VENT, VALVE- PIPE
DISCHANGE TO DRAIN
PIPE
VARIABLE AIR VOLUME UNIT NUMBER AS
PER SCHEDULE
SUPPLY DUCT
AIR TURNING DEVICE (NOT A
SPLITTER DAMPER)
EXHAUST/RETURN DUCT
SECTION
IMAGE OR SECTION ON THE SAME SHEET.X
DUCT-SOUNDLINED-CLEAR INSIDE SIZE IN INCHES.
FIRST DIMENSION IS SIDE SHOWN.
240 x 120
DUCT SIZE TRANSITION
DUCT-SIZE IN INCH. FIRST DIMENSION
IS SIDE SHOWN.
240 x 120
DUCT INCLINED UP IN RESPECT TO AIR
FLOW
UP
DUCT INCLINED DOWN IN RESPECT TO
AIR FLOW
DN
DUCT ELBOW WITH TURNING VANES
(SQUARE ELBOW)
DUCT ELBOW WITH TURNING VANES (RADIUS ELBOW)
DUCT ELBOW TURNED UP
DUCT ELBOW TURNED DOWN
COLUMN LETTERS OR NUMBERC
COMBINATION CEILING AIR-RETURN INLET
SIZE IN INCHES
CAPACITY-EXHAUST/RETURN
W/FLEXABLE CONNECTION.
ØTYPE
CAPACITY
SIZE
SQUARE OR
RECTANGLE TYPE
CEILING EXHAUST-RETURN INLET
SIZE IN INCHES CAPACITY IN CFM
TYPE AS PER SPEC.
CEILING DIFFUSER, NECK SIZE
& OVERALL SIZE IN INCH.
CAPACITY IN CFM TYPE AS
PER SPEC. BLANK OFF
SHOWN AS SHADED AREA.
HINGED ACCESS DOOR
HOT WATER RETURN
HOT WATER SUPPLY
ZONE
WC
WB
W/ W
VEL
VD
VAV
VA
TYP
TSP
STD
SPD
SP
SPEC
SCRD
S
RO
RPM
RH
RET
REQD
REG
RA
PSIG
PSIA
PRESS
3 PH
1 PH
OAI
OA
NTS
N.O.
NO
NK
NIC
N.C.
NC
MIN.
MAX.
MAN.
MAT
LWT
LD
LAT
KWH
KW
INSUL
IN
ID
HTG
HP
HC
HZ
GR
GPM
GA
FT
FPM
FLEX
FL
FC
DEGREES FAHRENHEIT°F
EXH
EWT
ETR
EL
EFF
EAT
E
DIA
DFL
DBT
DB
CR
COT
CONC
CLG
CL
CFM
CC
BTUH
BTU
BOD
AMP
AH
AD
DEMOLITION OF DUCT/PIPE/EQUIPMENT
SUPPLY AIRSA
TRANSFER AIRT/A
EXISTING DUCT/PIPE/EQUIPMENT
DUCT SECURITY BARS
SCOPE OF WORK
1. THE CONTRACTOR SHALL PROVIDE COMPETE AND OPERATING SYSTEMS THAT
COMPLY WITH P100 AND THE INTERNATIONAL BUILDING CODE.
2. SUBMIT QUALIFICATION DATA, SAMPLE TEST AND BALANCE FORMS, TESTING
PLAN, AND SAMPLES.
3. OBTAIN SECURITY CLEARANCES REQUIRED TO EXECUTE WORK. END USER
HAS STRINGENT, SPECIFIC SECURITY REQUIREMENTS, IN ORDER TO EXECUTE
CONTROLS THE CONTRACTOR REQUIRES ENT CLEARANCE. COORDINATE
WITH GSA IT STAKEHOLDER.
4. PERFORM PRE-ALTERATION TESTING OF AIR HANDLING UNIT AND VAV
EQUIPMENT. SUBMIT REPORT.
5. SCHEDULE EFFORTS IN AREAS OUTSIDE OF THE BUILDOUT AREA WITH
PROPERTY MANAGEMENT. EFFORTS SHALL BE PERFORMED OFF HOURS. THE
CONTRACTOR SHALL CLEAN THE SPACE AND LEAVE THE EQUIPMENT IN
WORKING ORDER AT THE START IF NORMAL BUSINESS HOURS.
6. EXECUTE DEMOLITION EFFORTS. RECYCLE SHEET METAL.
7. PROVIDE COORDINATION DRAWINGS THAT ARE COORDINATED WITH OTHER
TRADES, EXISTING CONDITIONS AND EQUIPMENT CLEARANCES. SUBMIT FOR
APPROVAL. INCLUDE ALL-TRADES SIGN OFF.
8. PROVIDE PRODUCT DATA SUBMITTALS FOR REVIEW AND COMMENT. NOTE
THAT PRODUCT DATA IS NOT A COORDINATED SHOP DRAWING.
9. PROVIDE SHEET METAL DUCTS, DUCT INSULATION, CONTROLS, SUPPORTS
AND TESTING TO COMPLETE INSTALLATION.
10. PROVIDE MODIFICATIONS TO THE BUILDING AUTOMATION SYSTEM TO
ACCOMMODATE NEW THERMOSTAT LOCATIONS.
11. PERFORM TESTING AND BALANCING OF EQUIPMENT AND CONTROLS.
SYSTEMS SHALL INTEGRATE WITH BAS AND PERFORM AS SPECIFIED.
12. PROVIDE OPERATIONS AND MAINTENANCE MANUAL. INCLUDE AS-BUILDS,
TESTING, WARRANTY, CONTROLS, AND TRAINING. SUBMIT GSA SIGN OFF THAT
EQUIPMENT IS VISIBLE FROM FRONT END
THE CONTRACTOR SHALL PERFORM TESTING AND INVESTIGATION OF THE EXISTING SYSTEMS
DESCRIBED WITHIN THE DOCUMENTS. SCHEDULE AND PERFORM TESTING OF SYSTEMS SUCH
THAT TESTING HAS BEEN SATISFACTORILY EXECUTED PRIOR TO THE SHEET OF DEMOLITION.
PROVIDE ALL NECESARRY PORTS FOR DUCTS, PIPES, ETC.
1. PERFORM TESTING EFFORT ON AIRFLOW DISTRIBUTION SYSTEM. PERFORM TESTING TO
DETERMINE FLOW AT DIFFUSERS, GRILLES.
A. VAV BOXES:
- AIR FLOW AT BAS
- TOTAL AIRFLOW AIR OUTLETS
M000
MECHANICAL STANDARDS
M000
GREAT LAKES REGION 5
PROPERTY OF THE
UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
DO NOT REMOVE THIS NOTICE.
PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
LIMITED OFFICIAL USE
MARK DESCRIPTION DATE
t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
©2022 Bailey Edward Design Design Firm License No. 184-001962
GENERAL SERVICE ADMINISTRATION
REGION 5 CHICAGO, IL
NAME
STREET
CITY/STREET/ZIP
BUILDING NO.
OTHER
BUILDING NOs.
PROJECT
DESCRIPTION
PROJECT NO.
DRAWING TITLE
TYPE
FILE NAME
FLOOR NO.
DRAWN BY
CHECKED BY
DRAWING NO.
17005 - 020019 - 00
JPB SHEET SIZE: 24 X 36
DATE: 10.28.22
SHEET OF
BU
ILD
IN
G
PJ
CT
DR
AW
IN
G
KWL
USDC & USBC TRANSACTION WINDOWS
(IN0096ZZ)
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST, SOUTH
BEND, IN 46601-2122
100% CD 10.28.22
PE19500200
STATE OF
PROFESS I ONA L ENG I N
EE
R
I N D I A N A
KE
NT
W. LOCKE, JR.
signature date 10/28/2022 license expires on 07-31-2023
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
23.01
23.02
23.02 23.03
23.04 02.04
02.04
02.04
US. DISTRICT COURT
CLERK'S OFFICE
US. DISTRICT COURT
CLERK'S OFFICE RECEPTION
02.02
02.03
02.01
02.04
02.04
02.04
M130
MECHANICAL PLANS
M130
GREAT LAKES REGION 5
PROPERTY OF THE
UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
DO NOT REMOVE THIS NOTICE.
PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
LIMITED OFFICIAL USE
MARK DESCRIPTION DATE
t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
©2022 Bailey Edward Design Design Firm License No. 184-001962
GENERAL SERVICE ADMINISTRATION
REGION 5 CHICAGO, IL
NAME
STREET
CITY/STREET/ZIP
BUILDING NO.
OTHER
BUILDING NOs.
PROJECT
DESCRIPTION
PROJECT NO.
DRAWING TITLE
TYPE
FILE NAME
FLOOR NO.
DRAWN BY
CHECKED BY
DRAWING NO.
17005 - 020019 - 00
JPB SHEET SIZE: 24 X 36
DATE: 10.28.22
SHEET OF
BU
ILD
IN
G
PJ
CT
DR
AW
IN
G
KWL
USDC & USBC TRANSACTION WINDOWS
(IN0096ZZ)
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST, SOUTH
BEND, IN 46601-2122
100% CD 10.28.22
PE19500200
STATE OF
PROFESS I ONA L ENG I N
EE
R
I N D I A N A
KE
NT
W. LOCKE, JR.
signature date 10/28/2022 license expires on 07-31-2023
MECHANICAL
NORTHNORTH
1ST FLOOR N.T.S.
ROBERT GRANT FEDERAL BLDG. & U.S.
COURTHOUSE, 204 S MAIN ST, SOUTH
BEND, IN 46601-2122
KEYPLAN
02.01 REMOVE & RELOCATE SUPPLY DIFFUSSER.
02.02 REMOVE LENGTH OF RETURN DUCT.
02.03 REMOVE RETURN GRILLE AND BRANCH DUCT.
02.04 EXISTING LEAD PAINT FOUND: GREEN PAINT ON CEILING
COLUMNS ABOVE DROP CEILING, CREAM PAINT ON THE
CEILING AND PLASTER WALLS ABOVE DROP CEILING AND
BEHIND DRYWALL, WHITE PAINT ON EXPOSED CEILING
OF THE BASEMENT. COORDINATE INSTALLATION WITH
SPEC 02 83 00 LEAD-BASED PAINT MITIGATION PER
AUGUST MACK ENVIRONMENTAL SCOPE OF WORK.
23.01 NEW LOCATION FOR RELOCATED SUPPLY.
23.02 NEW INSULATED SUPPLY DUCT.
23.03 RELOCATED RETURN GRILLES.
23.04 NEW INSULATED RETURN DUCTS.
1ST LEVEL PARTIAL NEW WORK MECHANICAL PLAN
US. DISTRICT COURT CLERK'S OFFICE RECEPTION DESK
SCALE: 3/8"=1'-0" SCALE: 3/8" = 1'-0"
0 2' 4'
1ST LEVEL PARTIAL DEMO MECHANICAL PLAN
US. DISTRICT COURT CLERK'S OFFICE RECEPTION DESK
SCALE: 3/8"=1'-0" SCALE: 3/8" = 1'-0"
0 2' 4'
NORTH NORTH
DUAL-ACTION MANUAL PULL STATION, MOUNTED AT 44" AFF
TOGGLE SWITCH, DIMMABLE, MOUNTED AT 48" AFF, U.N.O.("3W" DENOTES 3-WAY)
INDICATES EXISTING TO REMAIN
INDICATES NEW
INDICATES COMPONENT TO BE REMOVED
EXIST EXISTING
FA FIRE ALARM
FULL LOAD AMPEREFLA
GROUND FAULT CIRCUIT INTERRUPTERGFI OR GFCI
GRD GROUND, GROUNDING
HP HORSEPOWER
JB JUNCTION BOX
KVA KILOVOLT AMPERE
AFF ABOVE FINISHED FLOOR
AMP OR A AMPERE
CCT CIRCUIT
CLG CEILING
DISC DISCONNECT
EC ELECTRICAL CONTRACTOR
ELECT ELECTRICAL
EM EMERGENCY
MINIMUMMIN
NOT IN CONTRACTNIC
NOT TO SCALENTS
PHASEPH OR Ø
RECEPTACLERECEP
TRANSFORMERXFMR
TYP TYPICAL
VOLTV
WATT OR WIREW
NIGHT LIGHTNL
KW KILOWATT
MECHANICAL CONTRACTORMC
MFR MANUFACTURER
D DIMMER
UNLESS NOTED OTHERWISEU.N.O.
XR
XN
X
MEP MECHANICAL, ELECTRICAL, PLUMBING
1. EXISTING ELECTRICAL SYSTEMS SHOWN ON THE DRAWINGS ARE BASED ON VISUAL INSPECTION AND EXISTING DRAWINGS. BUT THEY MAY NOT REFLECT THE EXISTING CONDITION IN EVERY CASE. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID AND VERIFY EXISTING
CONDITIONS.
2. THE BUILDING WHERE THE WORK TO BE DONE IS IN USE. SCHEDULE ANY ELECTRICAL WORK (ESPECIALLY ELECTRICAL SYSTEM DISCONNECTIONS OR RECONNECTIONS) WITH THE CONTRACTING OFFICER AND BUILDING MANAGEMENT. MAKE ARRANGEMENTS AT LEAST TWO (2) WEEKS PRIOR TO PROPOSED SCHEDULES OF WORKS. ARRANGE WORK SO AS NOT TO INTERRUPT ANY ELECTRICAL POWER, TELEPHONE, FIRE, COMMUNICATION, AND OTHER SYSTEMS DURING NORMAL WORKING HOURS.
A. WHERE CORE DRILLING AND CUTTING OF FLOORS OR WALLS IS REQUIRED, USE METAL DETECTORS OR OTHER APPROVED DEVICES TO
DETERMINE AND AVOID INTERFERENCE WITH EXISTING CONCEALED CONDUITS & PIPES.
B. USE GREAT DILIGENCE AND CARE IN DISCONNECTING VARIOUS SYSTEMS. RECONNECT SYSTEMS AND RESTORE ALL THAT SERVE ADJACENT AREAS IF SUCH SYSTEMS HAVE BEEN DISRUPTED DURING DEMOLITION WORK WITHOUT ANY EXPENSE FOR THE AFFECTED USING AGENCY OR THE BUILDING. EXTEND CONDUIT & WIRING AS REQUIRED TO MAINTAIN OPERATION OF REMOVING EQUIPMENT OR DEVICES.
C. COORDINATE ALL DEMOLITION WORK WITH OTHER TRADES AS REQUIRED.
3. ELECTRICAL ITEMS REMOVED AND NOT RELOCATED SUCH AS LIGHTING FIXTURES, SWITCHES, RECEPTACLES, BREAKERS, WIRE, ET. REMAIN THE
PROPERTY OF THE OWNER AND SHALL BE STORED OR DISPOSED OF AS DIRECTED BY OWNER.
4. ALL UNUSED CONDUITS OR ANY ELECTRICAL ITEMS THAT ARE ABANDONED AND WHERE ELECTRICAL ITEMS ARE BEING REMOVED SHALL HAVE ALL WIRING REMOVED BACK TO THE SOURCE OR FEEDER JUNCTION BOX SERVING THE DEVICE OR BACK TO THE FIRST OUTLET WHICH IS LEFT UNAFFECTED BY THE CHANGES. STUBS SHALL BE PLUGGED FLUSH WITH FLOOR, CEILING SLABS, OR WALLS. ALL EXPOSED LOW VOLTAGE CABLINGS, CONDUITS AND FITTINGS, INCLUDING ABOVE DROP CEILINGS THAT ARE ABANDONED (NOT USED) SHALL BE REMOVED UNLESS OTHERWISE NOTED ON THE DRAWINGS OR DIRECTED BY THE BUILDING MANAGEMENT AND CONTRACTING OFFICER.
5. WHERE EXISTING ELECTRICAL ITEMS (POWER, COMMUNICATION, FIRE ALARM EQUIPMENT, DEVICES, LIGHTING FIXTURES, ETC) THAT ARE INSIDE OR OUTSIDE THE CONTRACT LIMITS OF CONSTRUCTION ARE TO REMAIN BUT ARE AFFECTED BY THE EXECUTION OF ELECTRICAL WORK SUCH AS REMOVAL, MOVING, OR RECONDITIONING OF WALLS AND CEILINGS SHALL BE DISCONNECTED, REMOVED, CLEANED, REWORKED, AND REINSTALLED IN-LINE WITH NEW WALLS OR CEILINGS. PROVIDE ALL NECESSARY MATERIALS AND LABOR AND REWIRE IN ACCORDANCE WITH PRESENT CODE REQUIREMENTS.