RFI Log 2026 09 10.pdf
PDF 3 MB Posted
- Attached to
- Installation of Commercial Gate - Houlton, Maine
- Solicitation number
- 47PC5226Q0134
- Issued by
- Not on record
About this file
This is a Request for Information (RFI) document for federal contract opportunity 47PC5226Q0134 regarding the installation of a commercial parking control gate at the Houlton Land Port of Entry (LPoE) in Houlton, Maine. The RFI consists of five question-and-answer pairs that clarify submission and project requirements for prospective contractors.
Key clarifications include: (1) an SF 24 Bid Bond/20% bid guarantee is not required with quotes; (2) contractors must submit form SF1442 only; (3) experience requirements outlined in Section II.D(2) apply to this gate project; (4) past performance and experience from proposed subcontractors may be used to satisfy comparable project requirements; and (5) the gate setup consists of a single DKS door king 1602 24-foot parking control gate with double aluminum arms, not two separate gates. The project specifications include ground preparation with a 5'x6'x8" concrete slab with rebar, two non-k-rated bollards 3' high, asphalt patching per Maine DOT standards, and a 26'-3 13/16" electrical line surface-mounted to the roof. The gate system features octagonal lighted arm options, pedestrian protection system, heated gate controller, beeper operation, and traffic control light mounted to the canopy post. Additional work includes hardwiring an interior booth switch for gate control, installing a STOP sign on the canopy post, and ensuring proper electrical conduit installation with waterproofing. The project manager is Kevin R Dessureault, and the facility is identified as BLDG # ME0061BH, N3798597.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Request for Information (RFI)
47PC5226Q0134
Installation of Commercial Gate - Houlton, Maine
Houlton LPoE
1 | Page
Q# Question Answer
001 Whether an SF 24 Bid Bond / 20% bid guarantee is required with the quote.
No, it is not required with the quote.
Whether we should submit SF 18, SF 1442, or both.
SF1442
Whether the experience requirements in Section
II.D(2) are intended for this gate project.
Yes
Whether we may use the past performance/experience of a proposed subcontractor to satisfy the comparable project requirements.
Yes
Could you clarify the barrier gate setup? We need to confirm whether two gates with 24' arms are needed, or if the roadway itself is 24' wide with two barrier gates covering it.
Please see images attached.
Ground Prep:
• Install 5' x6' x8" concrete slab with rebar, seal concrete
• 2-non k rated Bollards 3' high 8" round with yellow plastic sleeves
• Patch in any damaged Asphalt per Maine DOT standards,
• Install power through sleeve in concrete then surface
26'-3 13/16" Electrical line for gate:
• Surface mount to roof ! Paint to match column and roof.
V Properly seal penetration through roof.
• Mount STOP Here sign to canopy post
• Hard wire switch inside booth to control gate.
I I " 11 � r1 ,---------'i'f1I "fl1 =1�=====nil
Or an Approved Equal DKS door king 1602, 24' parking control gate with double aluminum arms.
• Operate beeper
• Octagonal lighted arm option
• Pedestrian protection system
• Heated Gate controller
• Traffic control light mounted to canopy post
I
(D
LO
r---lock upright capability. , , , Concrete slab shall not protrude �into drive lane. .
5'x6'x 8" concrete slab with rebar, Sleeve under concrete to canopy post for electrical
Surface mounted Bollards with 4-½" x 6" concrete anchors.
---2-4'--4-7/�1-6"--*
• Electrical wire shall be rated for exterior use in conduit.
• Paint conduit to match column and roof.
• when fastening conduit to roof ensure proper waterproofing fasteners. ---- p-·-·-·-·-·-·-·-·-·-·-·-·-·-·-ctrical panel inside booth for gate power.
ardwire switch for gate shall be installed by service window of ooth, at officers convenient location
Penetrate roof per electrical and roofing code
Label additional breakers installed
General Service
Administration
Houlton LPOE 27 Custom Loop Rd
Houlton, ME
BLDG # ME0061BH
N3798597
PM: Kevin R Dessureault
| RFI log for Solicitation No. 47PC5226Q0134 2026 09 10.pdf |
| Tab 2 - Design {Houlton Commercial Gate N3798597} (1).pdf |
| houlton Comm Gate 2026 N3798597 Model (1) |
| houlton Comm Gate 2026 N3798597 Model (2) |
| houlton Comm Gate 2026 N3798597 Model (3) |
File details come from the government source that posted it. Updated .