The document is a set of architectural construction drawings for the Alger Correctional Facility Doors and Windows Upgrades project, prepared by OHM Architects for the State of Michigan's Department of Technology, Management and Budget (DTMB) and Department of Corrections. The project focuses on upgrading doors and windows in Building 500 (Maintenance) at the Alger Correctional Facility located at N6141 Industrial Park Drive in Munising, Michigan. The plans detail comprehensive renovation work including removing existing doors, windows, and associated architectural elements, and installing new aluminum and hollow metal doors, frames, glazing, and related components. The project is dated February 25, 2025, with detailed demolition and construction plans for specific rooms such as the main entry, generator room, warehouse, maintenance shop, storage areas, and vehicle maintenance spaces.
The drawings include specific technical specifications for door and window replacements, with detailed schedules indicating precise measurements, materials, finishes, and glazing types. The project appears to be focused on upgrading security and functionality, with special attention to door hardware, frame types, and security considerations typical of a correctional facility. The plans specify various glazing types, including security-rated options like 1 1/8" air-gap security glazing and 3/8" laminated polycarbonate security glazing. The renovation will involve carefully removing and salvaging certain existing materials, repairing concrete and masonry, and ensuring minimal disruption to the facility's operations, with specific notes about maintaining security fencing and coordinating work around existing infrastructure.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
O
R
R
ARCHITECTS. ENGINEERS. PLANNERS
OHM-ADVISORS.COM
PR
EL
IM
IN
AR
Y
CO
NS
TR
UC
TI
ON
FI
NA
L R
EC
OR
D
DA
TE
IS
SU
ED
F
OR
DT
MB
F
ILE
N
UM
BE
R:
ID
EN
TI
FI
CA
TI
ON
N o.
SH
EE
T
DE
SI
GN
ED
DR
AW
N
CH
EC
KE
D
AP
PR
OV
ED
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
OHM PROJECT No.
2/1
.JB
B
VV TD VV LM
F
EB
G-
AL
GE
R
CF
D
OO
RS
A
ND
W
IN
DO
W S
UP
GR
AD
ES
DT
MB
AL
GE
R
CO
RR
EC
TI
ON
AL
F
AC
ILI
TY
7136240040
BU
ILD
IN
G
0 (
MA
IN
TE
NA
NC
E)
C
OV
ER
S
HE
ET
424 HANCOCK STREET
HANCOCK, MICHIGAN 49930
PH 906.482.0535 | F 906.482.6453
GENERAL NOTES:
1. GENERAL NOTES APPLY TO ALL DRAWINGS
2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS
NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE
ARCHITECT.
3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS
NOTED OTHERWISE.
4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E.
EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF
CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE
PROCEEDING WITH WORK.
5. CONTRACTOR SHALL PAY ALL PERMIT FEES.
6. CONTRACTOR SHALL MAINTAIN THE IMMEDIATE CONSTRUCTION SITE IN A SECURE,
CLEAN AND SAFE MANNER.
7. PROTECTION: CONTRACTORS SHALL BE SOLELY RESPONSIBLE FOR TAKING ALL
STEPS NECESSARY TO PROTECT THE PUBLIC FROM INJURY AND ADJACENT PROPERTY
DAMAGES DURING CONSTRUCTION.
8. REPAIR ALL EXISTING CONSTRUCTION AFFECTED BY NEW WORK TO ITS ORIGINAL
CONDITION.
BUILDING 500 (MAINTENANCE) DRAWING INDEX:
G-000 COVER SHEET
G-001 CODE REVIEWS
I Certify That The Architectural Plans Were Prepared Under My Direct Supervision
ARCHITECTURAL
A-001 GENERAL INFORMATION
A-002 SITE KEY PLAN
500-D1 BUILDING 500 MAINTENANCE FIRST FLOOR DEMOLITION PLAN
500-D2 BUILDING 500 MAINTENANCE ENLARGED DEMOLITION PLANS
500-A1 BUILDING 500 MAINTENANCE FIRST FLOOR PLAN
500-A2 BUILDING 500 MAINTENANCE ENLARGED PLANS
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
STATE OF MICHIGAN
STATE FACILITIES ADMINISTRATION
DESIGN AND CONSTRUCTION DIVISION
STATE OF MICHIGAN
HEIDI WASHINGTON , Director
DEPARTMENT OF CORRECTIONS
OHM PROJECT No.
DATE:
DTMB File No.
7136240040
25 FEB 2025
PLAN REVIEW
472/19306.JBB
ADAM LACH, RA, DIRECTOR
ALGER CORRECTIONAL FACILITY
DOORS & WINDOWS UPGRADES
N6141 INDUSTRIAL PARK DRIVE
MUNISING, MI 49862
P:\7101_7200\7136240040_AlgerCFDoors&Windows\Drawings\Arch-IntDes\2-Arch Desktop\New Facilties Project\Sheets\7136240040-G-000 BUILDING 500 (MAINTENANCE).dwg, 2/26/2025 2:57:54 PM, _DWG To PDF.pc3
SEE CODE SHEET AND
ARCHITECTURAL SHEETS
FOR ARCHITECT'S SEAL
I Certify That The Structural Plans Were Prepared Under My Direct Supervision
R
ARCHITECTS. ENGINEERS. PLANNERS
OHM-ADVISORS.COM
PR
EL
IM
IN
AR
Y
CO
NS
TR
UC
TI
ON
FI
NA
L R
EC
OR
D
DA
TE
IS
SU
ED
F
OR
AC
CO
UN
TI
NG
T
EM
P:
DT
MB
F
ILE
N
UM
BE
R:
ID
EN
TI
FI
CA
TI
ON
N o.
SH
EE
T
DE
SI
GN
ED
DR
AW
N
CH
EC
KE
D
AP
PR
OV
ED
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
OHM PROJECT No.
2/1
.JB
B
VV TD VV LM
F
EB
G-
AL
GE
R
CF
D
OO
RS
A
ND
W
IN
DO
W S
UP
GR
AD
ES
DT
MB
AL
GE
R
CO
RR
EC
TI
ON
AL
F
AC
ILI
TY
7136240040
CO
DE
R
EV
IE
W
424 HANCOCK STREET
HANCOCK, MICHIGAN 49930
PH 906.482.0535 | F 906.482.6453
P:\7101_7200\7136240040_AlgerCFDoors&Windows\Drawings\Arch-IntDes\2-Arch Desktop\New Facilties Project\Sheets\7136240040-G-001.dwg, 2/26/2025 2:55:06 PM, _DWG To PDF.pc3
BUILDING 500 - MAINTENANCE
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
ABBREVIATIONS
MATERIAL SYMBOLS
N
A
DETAIL TITLE2
PLAN SYMBOLS GENERAL NOTES
R
ARCHITECTS. ENGINEERS. PLANNERS
OHM-ADVISORS.COM
PR
EL
IM
IN
AR
Y
CO
NS
TR
UC
TI
ON
FI
NA
L R
EC
OR
D
DA
TE
IS
SU
ED
F
OR
AC
CO
UN
TI
NG
T
EM
P:
DT
MB
F
ILE
N
UM
BE
R:
ID
EN
TI
FI
CA
TI
ON
N o.
SH
EE
T
DE
SI
GN
ED
DR
AW
N
CH
EC
KE
D
AP
PR
OV
ED
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
OHM PROJECT No.
2/1
.JB
B
VV TD VV LM
F
EB
A-
AL
GE
R
CF
D
OO
RS
A
ND
W
IN
DO
W S
UP
GR
AD
ES
DT
MB
AL
GE
R
CO
RR
EC
TI
ON
AL
F
AC
ILI
TY
7136240040
GE
NE
RA
L I
NF
OR
MA
TI
ON
424 HANCOCK STREET
HANCOCK, MICHIGAN 49930
PH 906.482.0535 | F 906.482.6453
P:\7101_7200\7136240040_AlgerCFDoors&Windows\Drawings\Arch-IntDes\2-Arch Desktop\New Facilties Project\Sheets\7136240040-A-001.dwg, 2/26/2025 2:55:10 PM, _DWG To PDF.pc3
OHM-ADVISORS.COM
PR
EL
IM
IN
AR
Y
CO
NS
TR
UC
TI
ON
FI
NA
L R
EC
OR
D
DA
TE
IS
SU
ED
F
OR
AC
CO
UN
TI
NG
T
EM
P:
DT
MB
F
ILE
N
UM
BE
R:
ID
EN
TI
FI
CA
TI
ON
N o.
SH
EE
T
DE
SI
GN
ED
DR
AW
N
CH
EC
KE
D
AP
PR
OV
ED
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
OHM PROJECT No.
2/1
.JB
B
VV TD VV LM
F
EB
A-
AL
GE
R
CF
D
OO
RS
A
ND
W
IN
DO
W S
UP
GR
AD
ES
DT
MB
AL
GE
R
CO
RR
EC
TI
ON
AL
F
AC
ILI
TY
7136240040
SI
TE
K
EY
P
LA
N
424 HANCOCK STREET
HANCOCK, MICHIGAN 49930
PH 906.482.0535 | F 906.482.6453
PROJECT BUILDING LOCATION PLAN1
P:\7101_7200\7136240040_AlgerCFDoors&Windows\Drawings\Arch-IntDes\2-Arch Desktop\New Facilties Project\Sheets\7136240040-A-002.dwg, 2/26/2025 2:55:06 PM, _DWG To PDF.pc3
WORK AREA:
REPAIR
WORK AREA:
REPAIR
WORK AREA:
REPAIR
WORK AREA:
REPAIR
WORK AREA:
REPAIR
WORK AREA:
REPAIR
WORK AREA:
REPAIR
WORK AREA:
REPAIR
WORK AREA:
REPAIR
WORK AREA:
REPAIR
R
ARCHITECTS. ENGINEERS. PLANNERS
OHM-ADVISORS.COM
PR
EL
IM
IN
AR
Y
CO
NS
TR
UC
TI
ON
FI
NA
L R
EC
OR
D
DA
TE
IS
SU
ED
F
OR
AC
CO
UN
TI
NG
T
EM
P:
DT
MB
F
ILE
N
UM
BE
R:
ID
EN
TI
FI
CA
TI
ON
N o.
SH
EE
T
DE
SI
GN
ED
DR
AW
N
CH
EC
KE
D
AP
PR
OV
ED
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
OHM PROJECT No.
2/1
.JB
B
VV TD VV LM
F
EB
0- D1
AL
GE
R
CF
D
OO
RS
A
ND
W
IN
DO
W S
UP
GR
AD
ES
DT
MB
AL
GE
R
CO
RR
EC
TI
ON
AL
F
AC
ILI
TY
7136240040
BU
ILD
IN
G
0 M
AI
NT
EN
AN
CE
F
IR
ST
F
LO
OR
D
EM
OL
IT
IO
N
PL
AN
424 HANCOCK STREET
HANCOCK, MICHIGAN 49930
PH 906.482.0535 | F 906.482.6453
BUILDING 500 MAINTENANCE FIRST FLOOR DEMOLITION PLAN1
P:\7101_7200\7136240040_AlgerCFDoors&Windows\Drawings\Arch-IntDes\2-Arch Desktop\New Facilties Project\Sheets\7136240040-500-D1.dwg, 2/26/2025 2:55:39 PM, _DWG To PDF.pc3
3 3
3 3
DEMOLITION PLAN GENERAL NOTES
1. REMOVE ALL MATERIALS AND DEBRIS CREATED DURING THE DEMOLITION AND/OR CONSTRUCTION
PROCESS AND DISPOSE OFF SITE IN A SAFE AND LEGAL MANNER.
2. PROVIDE TEMPORARY DUSTPROOF PARTITIONS WITH DOORS AS REQUIRED TO ADEQUATELY
SEPARATE OCCUPIED AREAS FROM CONSTRUCTION HAZARDS, NOISE AND DUST.
3. CONTINUOUSLY MAINTAIN ALL MEANS OF EGRESS AND ALL FIRE PROTECTION COMPONENTS FOR
ALL PORTIONS OF THE BUILDING THAT REMAIN OCCUPIED DURING CONSTRUCTION.
4. ALL DEMOLITION WORK REQUIRED ON THE EXISTING BUILDING AS CALLED FOR ON THE DRAWINGS
AND/ OR AS REQUIRED TO ACCOMMODATE THE RENOVATION WORK.
5. CAP, PATCH AND REPAIR ALL HOLES AND SURFACES IN WALLS, FLOORS AND CEILINGS WHERE
ARCHITECTURAL, STRUCTURAL, MECHANICAL AND/OR ELECTRICAL ITEMS ARE REMOVED AS A
RESULT OF THE DEMOLITION OPERATIONS.
6. PREPARE ALL DEMOLITION AREAS FOR NEW FINISHES.
7. REMOVE AND RELOCATE MECHANICAL AND ELECTRICAL ITEMS, INCLUDING PIPING, FIXTURES, EQUIPMENT, DUCTWORK, WIRING DEVICES, PANELS AND ACCESSORIES AS REQUIRED. REFER TO
MECHANICAL AND ELECTRICAL DRAWINGS FOR MECHANICAL AND ELECTRICAL DEMOLITION.
8. NOTIFY ARCHITECT OF ANY REQUIREMENTS FOR ACCESS PANELS NOT SHOWN ON DOCUMENTS
BEFORE PROCEEDING WITH WORK.
9. ITEMS NOTED EXISTING FOR CLARITY; ASSUME NO NEW WORK UNLESS NOTED OTHERWISE.
DEMOLITION PLAN KEY NOTES
1. REMOVE EXISTING ALUMINUM DOOR, FRAME AND HARDWARE.
2. REMOVE EXISTING GLAZING & PREP FOR NEW GLAZING. EXISTING FRAME TO REMAIN.
3. REMOVE EXISTING HM DOOR, FRAME AND HARDWARE.
4. REMOVE EXISTING 8" CMU & BRICK CAVITY WALL BELOW EXISTING SIDELITE. REMOVE PORTION OF
EXISTING WALL BELOW FINISHED FLOOR LEVEL AND PREP FOR NEW CONCRETE FLOOR SLAB AND FINISHED FLOOR INFILL TO MATCH EXISTING ADJACENT SURFACES. BRICK TO BE DISMANTLED AND
SALVAGED FOR RE-USE.
5. REMOVE DAMAGED TILE WALL , AND/OR BASE DOWN TO CONCRETE FLOOR SLAB. PREP FOR NEW TILE TO MATCH EXISTING. ASSUME LESS THAN 1 SQUARE FOOT OF MATERIAL PER LOCATION INDICATED.
6. PROVIDE TEMPORARY DUST PARTITION TO CEILING WITH EGRESS DOOR.
7. REMOVE DAMAGED BRICK; IF EXTENTS NOT NOTED ASSUME LESS THAN ONE SQUARE FOOT OF
MATERIAL PER LOCATION INDICATED.
8. REMOVE DAMAGED THIN SET QUARRY TILE AND QUARRY COVE BASE; IF EXTENTS NOT NOTED ASSUME
LESS THAN ONE SQUARE FOOT OF MATERIAL PER LOCATION INDICATED.
9. REMOVE EXISTING LINTEL. REVISE EXISTING CMU AND BRICK OPENING: REFER TO NEW WORK PLANS.
INSTALL BRICK VENEER AT OPENING. SALVAGE EXISTING BRICK FOR RE-USE.
10. CRITICAL TIMELINE OPENING.
11. STRIP AND CLEAN ENTIRE FRAME AND PREP FOR NEW PAINT. PAINT SECURITY FRAME TO MATCH
EXISTING COLORS.
12. REMOVE EXISTING COILING OVERHEAD DOOR, TRACK & EXTERIOR WEATHER SEAL. STRUCTURAL FRAME
AND BUMPERS TO REMAIN IN PLACE.
13. EXISTING OVERHEAD HEATER. REFER TO MECHANICAL & ELECTRICAL SHEETS FOR RELATED WORK.
14. EXISTING SECURITY FENCING SHALL REMAIN. ENGAGE SECURITY FENCE CONTRACTOR TO
TEMPORARILY REMOVE AND REINSTALL FENCING AS REQUIRED TO FACILITATE WORK ACTIVITIES. THE FENCE MAY ONLY BE REMOVED DURING ACTIVE WORK AND MUST BE SECURELY REINSTALLED BY THE END OF EACH WORK SHIFT UNLESS PRIOR APPROVAL FOR EXTENDED REMOAVAL IS GRANTED BY THE
WARDEN.
15. CLEAN GROUT JOINTS AS REQUIRED FOR NEW TUCK-POINTING AT 12" HIGH SOLDIER COURSE SILL.
16. REFER TO ELECTRICAL SHEETS.
17. REMOVE & STORE EXISTING WOOD WALL MOUNTED SHELF AND PREP FOR REINSTALL.
18. REMOVE EXISTING SECURITY GRILLE FROM EXISTING DOOR. CLEAN FRAMES AND PREP FOR NEW PAINT.
PAINT SECURITY FRAME TO MATCH EXISTING COLORS.
19. REMOVE EXISTING VCT OR THIN SET QUARRY TILE FLOORING FROM ENTRY. CLEAN AND PREP FOR
CONCRETE SEALER. REPAIR CONCRETE IF NECESSARY.
20. REMOVE EXISTING QUARRY TILE AND WALK-OFF MAT FRAME.
# DENOTES PLAN KEY NOTE ITEM USING NUMBERS BELOW. ALL PLAN KEY NOTES MAY NOT
APPLY TO THIS BUILDING.
R
ARCHITECTS. ENGINEERS. PLANNERS
OHM-ADVISORS.COM
PR
EL
IM
IN
AR
Y
CO
NS
TR
UC
TI
ON
FI
NA
L R
EC
OR
D
DA
TE
IS
SU
ED
F
OR
AC
CO
UN
TI
NG
T
EM
P:
DT
MB
F
ILE
N
UM
BE
R:
ID
EN
TI
FI
CA
TI
ON
N o.
SH
EE
T
DE
SI
GN
ED
DR
AW
N
CH
EC
KE
D
AP
PR
OV
ED
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
OHM PROJECT No.
2/1
.JB
B
VV TD VV LM
F
EB
0- D2
AL
GE
R
CF
D
OO
RS
A
ND
W
IN
DO
W S
UP
GR
AD
ES
DT
MB
AL
GE
R
CO
RR
EC
TI
ON
AL
F
AC
ILI
TY
7136240040
BU
ILD
IN
G
0 M
AI
NT
EN
AN
CE
E
NL
AR
GE
D
DE
MO
LIT
IO
N
PL
AN
S
424 HANCOCK STREET
HANCOCK, MICHIGAN 49930
PH 906.482.0535 | F 906.482.6453
DEMO PLAN AT DOOR 5011DEMO PLAN AT DOOR 5022DEMO PLAN AT DOOR 5033DEMO PLAN AT DOOR 5044DEMO PLAN AT DOOR 5115DEMO PLAN AT DOOR 5146
DEMO PLAN AT DOOR 5157DEMO PLAN AT DOOR 5238DEMO PLAN AT DOOR 5279DEMO PLAN AT DOOR 53310
P:\7101_7200\7136240040_AlgerCFDoors&Windows\Drawings\Arch-IntDes\2-Arch Desktop\New Facilties Project\Sheets\7136240040-500-D2.dwg, 2/26/2025 2:58:54 PM, _DWG To PDF.pc3
OHM-ADVISORS.COM
PR
EL
IM
IN
AR
Y
CO
NS
TR
UC
TI
ON
FI
NA
L R
EC
OR
D
DA
TE
IS
SU
ED
F
OR
AC
CO
UN
TI
NG
T
EM
P:
DT
MB
F
ILE
N
UM
BE
R:
ID
EN
TI
FI
CA
TI
ON
N o.
SH
EE
T
DE
SI
GN
ED
DR
AW
N
CH
EC
KE
D
AP
PR
OV
ED
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
OHM PROJECT No.
2/1
.JB
B
VV TD VV LM
F
EB
0- A1
AL
GE
R
CF
D
OO
RS
A
ND
W
IN
DO
W S
UP
GR
AD
ES
DT
MB
AL
GE
R
CO
RR
EC
TI
ON
AL
F
AC
ILI
TY
7136240040
BU
ILD
IN
G
0 M
AI
NT
EN
AN
CE
F
IR
ST
F
LO
OR
P
LA
N
424 HANCOCK STREET
HANCOCK, MICHIGAN 49930
PH 906.482.0535 | F 906.482.6453
BUILDING 500 MAINTENANCE FIRST FLOOR PLAN1
P:\7101_7200\7136240040_AlgerCFDoors&Windows\Drawings\Arch-IntDes\2-Arch Desktop\New Facilties Project\Sheets\7136240040-500-A1.dwg, 2/26/2025 2:58:18 PM, _DWG To PDF.pc3
ARCHITECTURAL PLAN NOTES
ARCHITECTURAL PLAN KEY NOTES
1. INSTALL NEW HOLLOW METAL FRAME AND DOOR.
2. INSTALL NEW ALUMINUM FRAME AND DOOR.
3. INSTALL NEW GLAZING AND GASKETS IN EXISTING ALUMINUM FRAMED WINDOWS.
4. INFILL REMOVED BRICK WITH SALVAGED MATERIAL; IF EXTENTS NOT NOTED,
ASSUME LESS THAN ONE SQUARE FOOT OF MATERIAL PER LOCATION INDICATED.
5. EXISTING OVERHEAD HEATER. REFER TO ELECTRICAL SHEETS FOR RELATED
WORK.
6. REINSTALL SECURITY FENCING AFTER GLAZING INSTALLATION IS COMPLETE.
COORDINATE REMOVAL, ADDITIONAL TEMPORARY SECURITY MEASURES AND
REPLACEMENT OF SECURITY FENCING AS REQUIRED TO REPLACE GLAZING WITH
OWNER. SEE KEYNOTE ON DEMOLITION PLAN.
7. INSTALL OVERHEAD COILING DOOR IN EXISTING OPENING.
8. INSTALL WEATHERPROOF COVER PLATE OVER EXISTING ABANDONED KEYPAD.
9. REPAIR DAMAGED CONCRETE BLOCK AND BASE USING A TWO-COMPONENT,
POLYMER-MODIFIED, NON-SAG MORTAR WITH CORROSION INHIBITOR, FOLLOWING
THE MANUFACTURER’S APPLICATION INSTRUCTIONS.
10. TUCKPOINTING; IF EXTENTS NOT NOTED ASSUME LESS THAN ONE SQUARE FOOT OF
MATERIAL PER LOCATION INDICATED.
11. CONCRETE SLAB INFILL AND ADJACENT WALL REPAIR AT LOCATIONS OF WALL
REMOVAL. INSTALL FLOOR AND WALL FINISHES AND WALL BASE TO MATCH
ADJACENT SURFACES.
12. REPAIR EXISTING THIN SET QUARRY TILE FLOORING AND/ OR TILE WALL BASE AT
DOOR EDGES AND AT AREAS OF NEW CMU WALL RELATED WORK. DO NOT OVERLAP
DOOR FRAME WITH WALL BASE.
13. REPAIR EXISTING THIN SET QUARRY FLOOR TILE IN DAMAGED AREAS. PATCH IN NEW
QUARRY TILE AND QUARRY COVE BASE WHERE DAMAGED AREAS PREVIOUSLY
REMOVED; IF EXTENTS NOT NOTED ASSUME LESS THAN ONE SQUARE FOOT OF
MATERIAL PER LOCATION INDICATED.
14. REINSTALL EXISTING WOOD WALL MOUNTED SHELF WITH APPROPRIATE FASTENERS
IN EXISTING CMU WALL.
15. INSTALL EXISTING SECURITY GRILLE FROM REMOVED DOOR ON NEW DOOR WITH
ONE-WAY SEX BOLTS TO MATCH EXISTING. COORDINATE WITH NEW DOOR FOR
COMPATIBILITY WITH GLAZING & HARDWARE AND MOUNT TO DOOR IN SIMILAR
FASHION.
16. INSTALL NEW NGP 413 SADDLE AS TRANSITION BETWEEN EXISTING CONCRETE AND
VCT, FASTENERS TO BE TAMPER RESISTANT TORX.
17. INSTALL NEW STEEL DOOR FRAME WITH JAMBS & HEADER. REFER TO DOOR FRAME
DETAILS. PATCH EXISTING WALLS AS REQUIRED.
18. PATCH EXISTING CONCRETE FLOOR AS NECESSARY TO CREATE A SMOOTH,
CONTINUOUS SURFACE. PREPARE SURFACE AND APPLY W.R. MEADOWS LIQUI-HARD
PER MANUFACTURER'S INSTRUCTIONS.
1. DO NOT SCALE DRAWINGS. IF DIMENSIONS CANNOT BE DETERMINED OR DOCUMENTS ARE IN CONFLICT, THE CONTRACTOR SHALL OBTAIN CLARIFICATION FROM THE ARCHITECT PRIOR TO CONTINUATION OF WORK.
2. FIELD VERIFY ALL PROJECT CONDITIONS PRIOR TO THE START OF WORK AND AS NEEDED THROUGHOUT THE DURATION OF CONSTRUCTION. BRING ANY DISCREPANCIES WHICH MAY SIGNIFICANTLY AFFECT NEW
CONSTRUCTION WORK TO THE ATTENTION OF THE ARCHITECT FOR REVIEW.
3. VERIFY SIZE AND LOCATION OF MECHANICAL AND ELECTRICAL EQUIPMENT, PADS, PENETRATIONS AND
SUPPORTS WITH MECHANICAL AND ELECTRICAL DRAWINGS.
4. PROVIDE WALL INFILL AND PATCHING AT LOCATIONS WHERE ITEMS ARE DEMOLISHED BUT NO REPLACEMENT IS INDICATED. ALL FINISHED WALLS WITHIN SCOPE OF PROJECT WILL BE FREE OF ANY DAMAGED AREAS.
5. SEE SPECIFICATION APPENDIX 1 - SPECIAL WORKING CONDITIONS FOR REQUIREMENTS FOR SEQUENCING/
EQUIPMENT OUTAGES.
6. ITEMS NOTED AS EXISTING FOR CLARITY; ASSUME NO NEW WORK UNLESS OTHERWISE NOTED.
DENOTES PLAN KEY NOTE ITEM USING NUMBERS BELOW. ALL PLAN KEY NOTES MAY NOT
APPLY TO THIS BUILDING.
OMIT
DOOR TYPES
DOOR FRAME TYPES
F1
F N
8" 8"
8"
" M
AX
SEE SCHEDULE FOR GLAZING TYPES
DOOR MATERIAL DESIGNATIONS:
AL STANDARD ALUMINUM
HDAL HEAVY DUTY ALUMINUM
HM HOLLOW METAL
ST STEEL
FRAME MATERIAL DESIGNATIONS:
AL STANDARD ALUMINUM
HDAL HEAVY DUTY ALUMINUM
HM HOLLOW METAL
DOOR/ FRAME FINISHDESIGNATIONS:
PF PREFINISHED
PT PAINTED
GLAZING:
GL-1 1" IGU W/ LOW-E (NON SECURE AREAS ONLY)
GL-1T SAME AS GL-1, W/ TEMPERED GLASS
GL-2 1 1/8" AIR-GAP SECURITY GLAZING
GL-3 3/8" LAMINATED POLYCARBONATE SECURITY GLAZING
DOOR SCHEDULE
DESCRIPTION MARK SIZE NO. OF LEAFS DOOR FRAME HDW
WIDTH HEIGHT THICK. TYPE MAT'L FINISH GLAZING TYPE MAT'L FINISH JAMB DETAIL HEAD DETAIL GLAZING DEPTH SET # Main entry DoorSubstation 501 3-10" 8'-0" 1 3/4" 2 F AL PF F8 AL PF 11/ 500-A2 13/ 500-A2 6" 20 Generator 502 3'-2" 7'-2" 1 3/4" 1 F AL PF F1 AL PF 11/ 500-A2 13/ 500-A2 6" 21 Warehouse 503 3'-2" 7'-2" 1 3/4" 1 F AL PF F1 AL PF 11/ 500-A2 13/ 500-A2 6" 22 Maint. Shop 504 3'-2" 7'-2" 1 3/4" 1 N AL PF GL-1 F1 AL PF 11/ 500-A2 13/ 500-A2 6" 21 Storage 511 2'-8" 7'-2" 1 3/4" 2 F AL PF F1 AL PF 11/ 500-A2 13/ 500-A2 6" 23 Veh Maint. 514 3'-2" 7'-2" 1 3/4" 1 N AL PF GL-1 F1 AL PF 11/ 500-A2 13/ 500-A2 6" 21 Corridor 515 3'-2" 7'-2" 1 3/4" 1 N AL PF GL-1 F1 AL PF 11/ 500-A2 13/ 500-A2 6" 21 Warehouse 523 3'-2" 7'-2" 1 3/4" 1 N AL PF GL-1 F1 AL PF 11/ 500-A2 13/ 500-A2 6" 21 Substation 527 3'-2" 7'-2" 1 3/4" 1 F AL PF F1 AL PF 11/ 500-A2 13/ 500-A2 6" 21 Locksmith 533 3'-2" 7'-2" 1 3/4" 1 F HM PT F1 HM PT 12/ 500-A2 14/ 500-A2 5-7/8" 24 Paint Storage
R
ARCHITECTS. ENGINEERS. PLANNERS
OHM-ADVISORS.COM
PR
EL
IM
IN
AR
Y
CO
NS
TR
UC
TI
ON
FI
NA
L R
EC
OR
D
DA
TE
IS
SU
ED
F
OR
AC
CO
UN
TI
NG
T
EM
P:
DT
MB
F
ILE
N
UM
BE
R:
ID
EN
TI
FI
CA
TI
ON
N o.
SH
EE
T
DE
SI
GN
ED
DR
AW
N
CH
EC
KE
D
AP
PR
OV
ED
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
OHM PROJECT No.
2/1
.JB
B
VV TD VV LM
F
EB
0- A2
AL
GE
R
CF
D
OO
RS
A
ND
W
IN
DO
W S
UP
GR
AD
ES
DT
MB
AL
GE
R
CO
RR
EC
TI
ON
AL
F
AC
ILI
TY
7136240040
BU
ILD
IN
G
0 M
AI
NT
EN
AN
CE
E
NL
AR
GE
D
PL
AN
S
424 HANCOCK STREET
HANCOCK, MICHIGAN 49930
PH 906.482.0535 | F 906.482.6453
ENLARGED PLAN AT DOOR 5011ENLARGED PLAN AT DOOR 5022ENLARGED PLAN AT DOOR 5033ENLARGED PLAN AT DOOR 5044ENLARGED PLAN AT DOOR 5115
ENLARGED PLAN AT DOOR 5146ENLARGED PLAN AT DOOR 5157ENLARGED PLAN AT DOOR 5238ENLARGED PLAN AT DOOR 5279ENLARGED PLAN AT DOOR 53310
DOOR JAMB DETAIL AT DOORS 501, 502, 503, 504, 511, 514, 515, 523, 52711
DOOR HEAD DETAIL AT DOORS 501, 502, 503, 504, 511, 514, 515, 523, 52713
DOOR JAMB DETAIL AT DOOR 53312
DOOR HEAD DETAIL AT DOOR 53314
P:\7101_7200\7136240040_AlgerCFDoors&Windows\Drawings\Arch-IntDes\2-Arch Desktop\New Facilties Project\Sheets\7136240040-500-A2.dwg, 2/26/2025 2:57:03 PM, _DWG To PDF.pc3
| Sheets and Views |
| G-000 BUILDING 100 (ADMINISTRATION) COVER SHEET |
| G-000 BUILDING 200 (SUPPORT SERVICES) COVER SHEET |
| G-000 BUILDING 300 (EDUCATION) COVER SHEET |
| G-000 BUILDING 500 (MAINTENANCE) COVER SHEET |
| G-000 BUILDING 600 (HAZARDOUS STORAGE) COVER SHEET |
| G-000 BUILDING 700 (GUARD POSTS) COVER SHEET |
| G-000 HOUSING UNIT 1 COVER SHEET |
| G-000 HOUSING UNIT 2 COVER SHEET |
| G-000 HOUSING UNIT 3 COVER SHEET |
| G-000 HOUSING UNIT 4 COVER SHEET |
| G-000 HOUSING UNIT 5 COVER SHEET |
| G-000 HOUSING UNIT 6 COVER SHEET |
| G-001 CODE REVIEW |
| A-001 GENERAL INFORMATION |
| OLE1 |
| 7136240040-V_NOTES |
| A-002 SITE KEY PLAN |
| 7136240040-LARGE SITE PLAN |
| 100-D1 BUILDING 100 ADMIN FIRST FLOOR DEMOLITION PLAN |
| 7136240040-DV_BLDG 100 ADMIN FLR 1 |
| 7136240040-V_NOTES |
| 100-D2 BUILDING 100 ADMIN SECOND FLOOR DEMOLITION PLAN |
| 7136240040-DV_BLDG 100 ADMIN FLR 2 |
| 7136240040-V_NOTES |
| 100-D3 BUILDING 100 ADMIN ENLARGED DEMOLITION PLANS |
| 7136240040-DV_BLDG 100 ADMIN FLR 1 |
| 7136240040-DV_BLDG 100 ADMIN FLR 2 |
| 7136240040-V_NOTES |
| 100-A1 BUILDING 100 ADMIN FIRST FLOOR PLAN |
| 7136240040-V_BLDG 100_ADMIN FLR 1 |
| 100-A2 BUILDING 100 ADMIN SECOND FLOOR PLAN |
| 7136240040-V_BLDG 100_ADMIN FLR 2 |
| 100-A3 BUILDING 100 ADMIN ENLARGED PLANS & SCHEDULES |
| 7136240040-V_NOTES |
| 7136240040-V_BLDG 100_ADMIN FLR 1 |
| 7136240040-V_BLDG 100_ADMIN FLR 2 |
| 100-A4 DOOR FRAME DETAILS |
| 100-A5 DOOR FRAME DETAILS |
| 200-D1 BUILDING 200 SUPPORT SERVICES FIRST FLOOR DEMOLITION PLAN |
| 7136240040-DV_BLDG 200 SUPPORT FLR 1 |
| 7136240040-V_NOTES |
| 200-D2 BUILDING 200 SUPPORT SERVICES ENLARD DEMOLITION PLANS |
| 7136240040-DV_BLDG 200 SUPPORT FLR 1 |
| 7136240040-V_NOTES |
| 200-A1 BUILDING 200 SUPPORT SERVICES FIRST FLOOR PLAN |
| 7136240040-V_BLDG 200 SUPPORT FLR 1 |
| 200-A2 BUILDING 200 SUPPORT SERVICES ENLARGED PLANS |
| 7136240040-V_NOTES |
| 7136240040-V_BLDG 200 SUPPORT FLR 1 |
| 200-A3 BUILDING 200 SUPPORT SERVICES DOOR SCHEDULE & DETAILS |
| 7136240040-V_NOTES |
| 300-D1 BUILDING 300 EDUCATION FIRST FLOOR DEMOLITION PLAN |
| 7136240040-DV_BLDG 300 EDUCATION FLR 1 |
| 300-D2 BUILDING 300 EDUCATION ENLARGED DEMOLITION PLANS |
| 7136240040-DV_BLDG 300 EDUCATION FLR 1 |
| 7136240040-V_NOTES |
| 300-A1 BUILDING 300 EDUCATION FIRST FLOOR PLAN |
| 7136240040-V_BLDG 300 EDUCATION FLR 1 |
| 300-A2 BUILDING 300 EDUCATION ENLARGED PLANS & DETAILS |
| 7136240040-V_NOTES |
| 7136240040-V_BLDG 300 EDUCATION FLR 1 |
| 500-D1 BUILDING 500 MAINTENANCE FIRST FLOOR DEMOLITION PLAN |
| 7136240040-DV_BLDG 500 MAINT FLR 1 |
| 500-D2 BUILDING 500 MAINTENANCE ENLARGED DEMOLITION PLANS |
| 7136240040-DV_BLDG 500 MAINT FLR 1 |
| 7136240040-V_NOTES |
| 500-A1 BUILDING 500 MAINTENANCE FIRST FLOOR PLAN |
| 7136240040-V_BLDG 500 MAINT FLR 1 |
| 500-A2 BUILDING 500 MAINTENANCE ENLARGED PLANS |
| 7136240040-V_NOTES |
| 7136240040-V_BLDG 500 MAINTENANCE ENLARGED LOCATION PLANS |
| 600-A1 BUILDING 600 HAZARDOUS STORAGE PLANS & DETAILS |
| 7136240040-DV_BLDG 600 HAZARD STOR |
| 7136240040-V_BLDG 600 HAZARD STOR |
| 7136240040-V_NOTES |
| 700-A1 BUILDING 700 GUARD POSTS PLANS & DETAILS |
| 7136240040-DV_BLDG GUARD TOWER 1-4 |
| 7136240040-V_BLDG GUARD TOWER 1-4 |
| 7136240040-V_NOTES |
| 1 HU-D1 HOUSING UNIT 1 (ASPEN) SECOND FLOOR DEMOLITION PLAN |
| 7136240040-DV_BLDG HU 1 FLR 2 |
| 7136240040-V_NOTES |
| 1 HU-A1 HOUSING UNIT 1 (ASPEN) SECOND FLOOR PLAN |
| 7136240040-V_BLDG HU 1 FLR 2 |
| 1 HU-A2 HOUSING UNIT 1 (ASPEN) ENLARGED PLAN |
| 7136240040-V_BLDG HU 1 FLR 2 |
| 7136240040-V_NOTES |
| 2 HU-D1 HOUSING UNIT 2 (BIRCH) SECOND FLOOR DEMOLITION PLAN |
| 7136240040-DV_BLDG HU 2 FLR 2 |
| 7136240040-V_NOTES |
| 2 HU-A1 HOUSING UNIT 2 (BIRCH) SECOND FLOOR PLAN |
| 7136240040-DV_BLDG HU 2 FLR 2 |
| 2 HU-A2 HOUSING UNIT 2 (BIRCH) ENLARGED PLAN |
| 7136240040-V_BLDG HU 2 FLR 2 |
| 7136240040-V_NOTES |
| 3 HU-D1 HOUSING UNIT 3 (CEDAR) SECOND FLOOR DEMOLITION PLAN |
| 7136240040-DV_BLDG HU 3 FLR 2 |
| 7136240040-V_NOTES |
| 3 HU-A1 HOUSING UNIT 3 (CEDAR) SECOND FLOOR PLAN |
| 7136240040-V_BLDG HU 3 FLR 2 |
| 3 HU-A2 HOUSING UNIT 3 (CEDAR) ENLARGED PLAN |
| 7136240040-V_BLDG HU 3 FLR 2 |
| 7136240040-V_NOTES |
| 4 HU-D1 HOUSING UNIT 4 (MAPLE) SECOND FLOOR DEMOLITION PLAN |
| 7136240040-DV_BLDG HU 4 FLR 2 |
| 7136240040-V_NOTES |
| 4 HU-A1 HOUSING UNIT 4 (MAPLE) SECOND FLOOR PLAN |
| 7136240040-V_BLDG HU 4 FLR 2 |
| 4 HU-A2 HOUSING UNIT 4 (MAPLE) ENLARGED PLAN |
| 7136240040-V_BLDG HU 4 FLR 2 |
| 7136240040-V_NOTES |
| 5 HU-D1 HOUSING UNIT 5 (PINE) SECOND FLOOR DEMOLITION PLAN |
| 7136240040-DV_BLDG HU 5 FLR 2 |
| 7136240040-V_NOTES |
| 5 HU-A1 HOUSING UNIT 5 (PINE) SECOND FLOORPLAN |
| 7136240040-V_BLDG HU 5 FLR 2 |
| 5 HU-A2 HOUSING UNIT 5 (PINE) ENLARGED PLAN |
| 7136240040-V_BLDG HU 5 FLR 2 |
| 7136240040-V_NOTES |
| 6 HU-D1 HOUSING UBIT 6 (SPRUCE) SECOND FLOOR DEMOLITION PLAN |
| 7136240040-DV_BLDG HU 6 FLR 2 |
| 7136240040-V_NOTES & DETAILS |
| 6 HU-A1 HOUSING UNIT 6 (SPRUCE) SECOND FLOOR PLAN |
| 7136240040-V_BLDG HU 6 FLR 2 |
| 6 HU-A2 HOUSING UNIT 6 (SPRUCE) ENLARGED PLANS |
| 7136240040-V_NOTES |
| 7136240040-V_BLDG HU 6 FLR 2 |
| E-001 ELECTRICAL NOTES AND SYMBOLS |
| 100-ED1 BUILDING 100 ADMIN FIRST FLOOR ELECTRICAL DEMOLITION PLAN |
| 7136240040-ELECTRICAL NOTES AND SYMBOLS |
| 100-E1 BUILDING 100 ADMIN FIRST FLOOR ELECTRICAL PLAN |
| 200-ED1 BUILDING 200 FIRST FLOOR ELECTRICAL DEMOLITION PLAN |
| 7136240040-ELECTRICAL NOTES AND SYMBOLS |
| 200-E1 BUILDING 200 ADMIN FIRST FLOOR ELECTRICAL PLAN |
| 600-E1 BUILDING 600 HAZARDOUS STORAGE ELECTRICAL PLANS |
| 7136240040-VE_HAZARDOUS WASTE |
| 7136240040-VE_HAZARDOUS WASTE(2) |
| 7136240040-ELECTRICAL NOTES AND SYMBOLS |
| 700-E1 BUILDING 700 GUARD POSTS ELECTRICAL PLANS |
| 7136240040-ELEC GAURD TOWER 1-4 |
| 7136240040-ELEC GAURD TOWER 1-4(2) |
| 7136240040-ELECTRICAL NOTES AND SYMBOLS |
| 1HU-ED1 HOUSING UNIT 1-5 SECOND FLOOR ELECTRICAL DEMOLITION PLAN |
| 7136240040-ELECTRICAL NOTES AND SYMBOLS |
| 1HU-E1 HOUSING UNIT 1-5 SECOND FLOOR ELECTRICAL PLAN |
| 6HU-ED1 HOUSING UNIT 6 (SPRUCE) SECOND FLOOR ELECTRICAL DEMOLITION PLAN |
| 7136240040-ELECTRICAL NOTES AND SYMBOLS |
6HU-E1 HOUSING UNIT 6 (SPRUCE) SECOND FLOOR ELECTRICAL PLAN