472_17032_RWG_Bellamy Creek WiFi Cabling Infrastructure_Add 01 Combined All.pdf
PDF 14 MB Posted
- Solicitation number
- RFQ-171-250000000206-3
- Issued by
- Huron County, Michigan
About this file
This is a Construction Bid Addendum No. 1 issued by the Michigan Department of Technology, Management and Budget's State Facilities Administration Design and Construction Division for Wi-Fi Cabling Infrastructure at Bellamy Creek Correctional Facility (File Number 472/17032.RWG). The addendum, issued on February 20, 2025, modifies the original bid documents with updated drawings and clarifications for the installation of Wi-Fi infrastructure throughout the facility's housing units and dormitory sections. The bid opening date is set for March 5, 2025. The project includes installation of WAP (Wireless Access Point) cabling, communications equipment, and fiber optic backbone connectivity throughout multiple housing units and dormitory sections.
The addendum includes specific clarifications regarding contractor access and equipment requirements, noting that contractors can use a Gator with enclosed cab through the Sallyport but no pickup trucks are allowed. Technical modifications include changes to housing unit rack layouts, cable ladder requirements, and fiber diagram updates for the Education comm room E2. The project requires dedicated pathways for WAP cabling using conduit and J-Hooks, replacement of existing tamper-resistant screws with torx type screws per MDOC standards, and installation of tamper-proof screws for WAP Installation and Oberon enclosure covers. The mandatory pre-bid meeting was held on February 10, 2025, at 11:00 AM on-site at Bellamy Creek C.F.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DTMB-0414 (Rev 12/17)
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
State Facilities Administration Design and Construction Division
CONSTRUCTION BID ADDENDUM NO. 1
This form identifies an Addendum to Bidding Documents, and incorporates interpretations or clarifications, modifications, acceptance of proposed “or equal” materials, and other information into the Bidding Documents. Addenda will be numbered by the Professional and distributed through www.michigan.gov/SIGMAVSS as an attachment.
TO:
ALL BIDDERS
DATE ISSUED
2/20/2025
PROJECT NAME
Wi-Fi Cabling Infrastructure – Bellamy Creek Correctional Facility
FILE NUMBER
472/17032.RWG
PROFESSIONAL
Commtech Design, Inc.
PROJECT DIRECTOR
Rob Gruesbeck
BID OPENING DATE:
3/5/2025
ADDENDUM ITEMS: (attach additional sheets and drawings if required)
Attachments;
1. Meeting Attendance record, Pre-Bid sign-in sheets.
2. TC701, TC708, TC709, TC710, TC807, TC808, TC809, TC810, TC811, TC812, TC813, TC814, TC815, TC816, TC817, TC818, TC819, TC820, TC823A
Specifications
1. None
Drawings:
1. TC701, note changes to COMMUNICATIONS EQUIPMENT LIST
2. TC708, TC709 see housing unit rack layout changes and requirement for moving and extending cables in the comm rooms of housing units.
3. TC710. Change fiber diagram to note Education comm room E2
4. TC808, TC810, TC812, TC814, TC816, TC818, TC820 See updated KEYED NOTES
5. See TC807, TC809, TC811, TC813, TC815, TC817, TC819 See updated KEYED NOTES and see revised comm room layout and required cable ladder. Rever to details on sheet TC708 and TC709
6. TC823A Add conduit and pullboxes as shown for routing of new fiber cable.
Questions:
1. None
Clarifications:
1. Contractor can have a Gator to go through Sallyport. No Pickup trucks. Gator must be enclosed cab with lockable doors.
2. Install all WAP cabling in its own pathway (Conduit and J-Hooks)
3. Allow extra time to remove existing tamper resistant screws thought the areas in the housing units above the cells. Replace remove screw with torx type per MDOC standards
4. Install tamper proof screws per specifications. This includes the screws needed for the WAP Installation and covers on the Oberon enclosures.
ACKNOWLEDGEMENT: This Addendum must be acknowledged by the Bidder in the space provided in the Bid Summary and Bid Form. Failing to acknowledge Addenda may be cause for the Bid to be rejected. Addenda will become part of the Contract Documents.
http://www.michigan.gov/SIGMAVSS
PROFESSIONAL: Bret Emerson DATE: 2/20/2025
APPROVED BY:
PROJECT DIRECTOR: Rob Gruesbeck DATE: 2/20/2025
TC701
TYPICAL CABLE LABELING
AT SURFACE BOX & PATCH PANEL 1
TC701
CAT-6 DATA PANEL
TYPICAL LABELING
ABBREVIATIONS
ABBREV. DESCRIPTION ABBREV. DESCRIPTION
TC701
PATCH CABLE DIAGRAM
TYPICAL CONNECTITY
CABLE SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
NETWORK EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
TC701
COMMUNICATIONS GROUNDING DETAIL
COMMUNICATION EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
COMMUNICATION SYMBOL LEGEND
SYMBOL DESCRIPTION
TC701
CABLING LEGENDS AND
DETAILS
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
L A
TC
H
, R A
, N C
A R
B , D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
C om m te ch
D es ig n
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
AutoCAD SHX Text
YY-APZZ
AutoCAD SHX Text
ADHESIVE LABEL
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text 33-3204-02
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text 33-3204-02
AutoCAD SHX Text
CAT-6 CABLE
AutoCAD SHX Text
BACK OF PATCH PANEL IN COMM ROOM
AutoCAD SHX Text NOTES: 1. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. 2. WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND SHALL BE WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND SHALL BE SELF-LAMINATING. 3. LABEL ALL SURFACE MOUNT BOXES WITH THE SAME CABLE NUMBER AS LABEL ALL SURFACE MOUNT BOXES WITH THE SAME CABLE NUMBER AS THE CABLE IS NUMBERED
AutoCAD SHX Text CABLE LABEL: XX = COMM ROOM NUMBER. SEE FLOORPLANS YY = FLOOR DESIGNATION BB=BASEMENT. LL=LOWER LEVEL. UL= UPPER LEVEL EX = EXTERIOR AP = WAP ZZ = AP NUMBER. O1 THRU 99
AutoCAD SHX Text NOTES: 1. LABEL EACH PATCH PANEL IN THE RACK WITH THE BUILDING AND LABEL EACH PATCH PANEL IN THE RACK WITH THE BUILDING AND THE FLOOR WHERE THE WAPS ARE INSTALLED. 2. INSTALL A LABEL TO EACH PATCH PORT ON THE PANEL DETAILING INSTALL A LABEL TO EACH PATCH PORT ON THE PANEL DETAILING THE WAP NUMBER. REFER TO SPREADSHEET PROVIDED BY STATE OF MICHIGAN AT TIME OF INSTALLATION. 3. ALL LABELS ADDED TO THE PANEL SHALL BE LASER PRINTED AND ALL LABELS ADDED TO THE PANEL SHALL BE LASER PRINTED AND CUT TO FIT. ALL NUMBERS SHALL EXACTLY ALIGN WITH THE LOCATION ON THE PATCH PANEL. 4. LABEL THE CABLES AT THE BACK OF THE PATCH PANEL WITH A LABEL THE CABLES AT THE BACK OF THE PATCH PANEL WITH A WRAP AROUND, LASER PRINTED, SELF-ADHESIVE LABEL. 5. THE CABLES SHALL BE TERMINATED ON THE PATCH PANEL IN THE CABLES SHALL BE TERMINATED ON THE PATCH PANEL IN NUMERICAL ORDER. NO EXCEPTIONS. 6. PROVIDE AND INSTALL A PATCH PANEL FOR EACH FLOOR OF A PROVIDE AND INSTALL A PATCH PANEL FOR EACH FLOOR OF A BUILDING WHERE WAPS ARE ON MULTIPLE FLOORS. 7. COMBINE BASEMENT CABLES OR MEZZANINE CABLES WITH EXTERIOR COMBINE BASEMENT CABLES OR MEZZANINE CABLES WITH EXTERIOR CABLES AND INSTALL ON THEIR OWN PATCH PANEL. EXTERIOR CABLES SHALL START ON THE RIGHT SIDE OF THE PATCH PANEL AND WORK TOWARDS THE MIDDLE. 8. WHERE THERE ARE MORE THAN 24 WAP CABLES IN A COMM ROOM WHERE THERE ARE MORE THAN 24 WAP CABLES IN A COMM ROOM THEN LABEL THE SECOND PANEL CABLES STARTING AT 15 THRU 48. EACH CABLE SHALL HAVE A UNIQUE NUMBER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LABEL PATCH PANEL USING INFORMATION FROM THE WAP LABELS
AutoCAD SHX Text
ADHESIVE LABEL (TYPICAL)
AutoCAD SHX Text 2G
AutoCAD SHX Text
TWO-GANG BOX - PROVIDED BY EC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
AC
AutoCAD SHX Text ABOVE COUNTER - INSTALL BACKBOX SAME HEIGHT AS OTHER ELECTRICAL OUTLETS ABOVE THE COUNTER.
AutoCAD SHX Text
PBO
AutoCAD SHX Text
PROVIDED BY OTHERS
AutoCAD SHX Text
AFF
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
PATCH CORD ORGANIZER - 1 UNIT HIGH
AutoCAD SHX Text
AFG
AutoCAD SHX Text
ABOVE FINISHED GROUND
AutoCAD SHX Text
PCO-2
AutoCAD SHX Text
PATCH CORD ORGANIZER - 2 UNITS HIGH
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AMERICAN WIRE GAUGE
AutoCAD SHX Text
PET
AutoCAD SHX Text
PROTECTED ENTRANCE TERMINAL
AutoCAD SHX Text
EMT
AutoCAD SHX Text
EMT TYPE CONDUIT
AutoCAD SHX Text
QTY
AutoCAD SHX Text
QUANTITY
AutoCAD SHX Text
EC
AutoCAD SHX Text
ELECTRICAL CONTRACTOR
AutoCAD SHX Text
%%UWIRELESS ACCESS POINT
AutoCAD SHX Text
YELLOW PATCH CABLES ARE TO BE PROVIDED AND INSTALLED BY OWNER
AutoCAD SHX Text GENERAL NOTES: 1. ALL PATCH CORDS BETWEEN PANEL AND ETHERNET SWITCH ARE ALL PATCH CORDS BETWEEN PANEL AND ETHERNET SWITCH ARE PROVIDED AND INSTALLED BY THE OWNER. 2. PROVIDE AND INSTALL PATCH CABLE AT THE WAP. SEE DETAILS PROVIDE AND INSTALL PATCH CABLE AT THE WAP. SEE DETAILS ON SHEET TC702 FOR PATCH CABLE AND CONNECTIVITY DETAILS.
AutoCAD SHX Text
PROVIDE AND INSTALL A CAT-6A PATCH CABLE, YELLOW, SEE DETAILS ON TC702
AutoCAD SHX Text
CAT-6A WAP CABLE
AutoCAD SHX Text
PATCH PANEL IN THE COMM ROOM
AutoCAD SHX Text
ETHERNET SWITCH IN THE COMM ROOM -PROVIDED BY OWNER
AutoCAD SHX Text
YELLOW PATCH CABLE FOR WAPS
AutoCAD SHX Text
CAT-6A CONNECTION
AutoCAD SHX Text
LL AP01
AutoCAD SHX Text
LABEL PATCH PANELS WITH THE WAP NUMBER
AutoCAD SHX Text
CAT-6A UTP CABLES FOR WIRELESS ACCESS POINTS SHALL BE YELLOW IN COLOR
AutoCAD SHX Text
MOHAWK
AutoCAD SHX Text M59230
AutoCAD SHX Text
CAT-6 UTP CABLES FOR DTMB CONNECTIVITY. SHALL BE BLUE IN COLOR
AutoCAD SHX Text
MOHAWK
AutoCAD SHX Text M58281
AutoCAD SHX Text
CAT-6A UNDERGROUND CABLES. SHALL BE BLACK IN COLOR
AutoCAD SHX Text
MOHAWK
AutoCAD SHX Text M59199
AutoCAD SHX Text
CATEGORY UTP CABLE, INDOOR, PLENUM RATED, EXTENDED DISTANCE. YELLOW
AutoCAD SHX Text
SUPERIOR ESSEX
AutoCAD SHX Text
PW6H-H72-6B
AutoCAD SHX Text
CATEGORY UTP CABLE, OUTDOOR, UNDERGOUND RATED, EXTENDED DISTANCE. BLACK
AutoCAD SHX Text
SUPERIOR ESSEX
AutoCAD SHX Text
PWO4-401-58
AutoCAD SHX Text
NOT USED
AutoCAD SHX Text
NOT USED
AutoCAD SHX Text
24 STRAND SINGLEMODE FIBER CABLE, OUTDOOR RATED
AutoCAD SHX Text
OCC
AutoCAD SHX Text
DX024DSLX9KR
AutoCAD SHX Text
12 STRAND MULTIMODE FIBER CABLE, 50 MICRON, PLENUM RATED -ARMORED
AutoCAD SHX Text
OCC
AutoCAD SHX Text
DZ012TALT9QP18
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text CORE ETHERNET SWITCH. PROVIDED BY OWNER. MOUNT IN RACK, INSTALL AND CONNECT TO INCOMING INTERNET, WIRELESS CONTROLLERS AND SWITCHES IN ALL OTHER BUILDINGS. PROVIDE ALL PATCH CORDS FOR CONNECTIVITY. INSTALL AND CONNECT
AutoCAD SHX Text
CISCO
AutoCAD SHX Text
PROVIDED AND INSTALLED BY OWNER
AutoCAD SHX Text BUILDING ETHERNET SWITCH 48 PORT. PROVIDED BY OWNER. MOUNT IN RACK, INSTALL AND CONNECT. PROVIDE ALL PATCH CORDS FOR FIBER AND WAP CONNECTIVITY.
AutoCAD SHX Text
CISCO
AutoCAD SHX Text
PROVIDED AND INSTALLED BY OWNER
AutoCAD SHX Text WIRELESS ACCESS POINT (WAP) INDOOR OR OUTDOOR. PROVIDED BY OWNER. INSTALL AND MOUNT AT THE LOCATIONS SHOWN ON FLOORPLANS. PROVIDE PATCH CABLE AT THE WAP LOCATION. PROVIDE HARDWARE REQUIRED FOR MOUNTING. OWNER TO PROVIDE MANUFACTURERS MOUNTS.
AutoCAD SHX Text
CISCO
AutoCAD SHX Text
PROVIDED BY OWNER INSTALLED BY CONTRACTOR
AutoCAD SHX Text
NA
AutoCAD SHX Text
NB
AutoCAD SHX Text
NC
AutoCAD SHX Text
LL AP02
AutoCAD SHX Text
LL AP03
AutoCAD SHX Text
LL AP04
AutoCAD SHX Text
LL AP05
AutoCAD SHX Text
LL AP06
AutoCAD SHX Text
LL AP07
AutoCAD SHX Text
LL AP088
AutoCAD SHX Text
LL AP09
AutoCAD SHX Text
LL AP10
AutoCAD SHX Text
LL AP11
AutoCAD SHX Text
LL AP12
AutoCAD SHX Text
LL AP13
AutoCAD SHX Text
XX-YY-APZZ
AutoCAD SHX Text
XX-YY-APZZ
AutoCAD SHX Text CABLE LABEL: XX = COMM ROOM NUMBER. SEE FLOORPLANS YY = FLOOR DESIGNATION BB=BASEMENT. LL=LOWER LEVEL. UL= UPPER LEVEL EX = EXTERIOR AP = WAP ZZ = AP NUMBER. O1 THRU 99
AutoCAD SHX Text
BLDG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text
PROVIDE AND INSTALL GROUND BAR AT EACH COMM ROOM
AutoCAD SHX Text
TYPICAL CRIMP LUG CONNECTIVITY
AutoCAD SHX Text GROUNDING NOTES: 1. INSTALL GROUND BAR AT EACH COMM ROOM. INSTALL GROUND BAR AT EACH COMM ROOM. 2. CONNECT THE GROUND BAR AS SHOWN IN THIS DIAGRAM CONNECT THE GROUND BAR AS SHOWN IN THIS DIAGRAM & AS DIRECTED IN THE GROUNDING SPECIFICATIONS. 3. ALL GROUND CONNECTIONS SHALL BE MADE WITH CRIMP ALL GROUND CONNECTIONS SHALL BE MADE WITH CRIMP LUGS ONLY. THIS APPLIES TO ALL CONNECTIONS TO THE GROUND BAR & THE CONNECTIONS TO THE ASSOCIATED EQUIPMENT. 4. GROUND CONNECTIONS SHALL BE MADE WITH A MINIMUM GROUND CONNECTIONS SHALL BE MADE WITH A MINIMUM OF #6 AWG CABLE. CABLES SHALL BE EQUIPPED WITH A GREEN SHEATH. 5. ALL CONNECTIONS TO THE GROUND BAR SHALL BE MADE ALL CONNECTIONS TO THE GROUND BAR SHALL BE MADE WITH PHOSPHER BRONZE BOLTS & NUTS. 6. ALL GROUND WIRES SHALL HAVE GREEN INSULATION ALL GROUND WIRES SHALL HAVE GREEN INSULATION UNLESS INSTALLED IN A PLENUM AREA. GROUND CABLES THAT MUST BE INSTALLED IN A PLENUM AREA SHALL BE BARE COPPER WIRE WITH GREEN TAPE AT ENDS. 7. INSTALL THE GROUND WIRE TO GROUND BUS ON INSTALL THE GROUND WIRE TO GROUND BUS ON ELECTRICAL PANEL
AutoCAD SHX Text
TELECOMMUNICATIONS GROUND BAR
AutoCAD SHX Text
BUILDING STEEL
AutoCAD SHX Text
LOCAL RECEPT. PANEL
AutoCAD SHX Text
#6 AWG
AutoCAD SHX Text
EXISTING RACK OR CABINET
AutoCAD SHX Text
NEW RACK OR CABINET
AutoCAD SHX Text
COMMUNICATIONS CABLE TRAY AND CABLE LADDER
AutoCAD SHX Text
PROTECTED ENTRANCE TERMINAL
AutoCAD SHX Text
#6 AWG
AutoCAD SHX Text
#6 AWG
AutoCAD SHX Text
#6 AWG
AutoCAD SHX Text
TYPICAL FOR ALL GROUND BARS
AutoCAD SHX Text
#6 AWG
AutoCAD SHX Text
AutoCAD SHX Text
TYPICAL ELECTRICAL PANEL
AutoCAD SHX Text
GROUND BUS
AutoCAD SHX Text
#6 AWG GREEN GROUND CABLE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text PATCH PANEL-24 PORT, EQUIPPED WITH 8-PIN MODULAR . PATCH PANEL SHALL BE COMPLETELY FILLED WITH MODULAR JACKS. NO OPENINGS ARE ALLOWED AT PROJECT COMPLETION. INSTALL YELLOW CAT-6A MODULAR CONNECTORS TO FILL THE PATCH PANEL. EQUIP WITH REAR CABLE ORGANIZER.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
PANEL:HPJ24 ORGANIZER:ECMBR3
AutoCAD SHX Text PATCH PANEL-24 PORT, EQUIPPED WITH 8-PIN MODULAR JACKS. FOR CAT-6 CABLES. THE PATCH PANEL SHALL BE COMPLETELY FILLED WITH MODULAR JACKS. NO OPENINGS ARE ALLOWED AT PROJECT COMPLETION. INSTALL BLUE CAT-6 MODULAR CONNECTORS TO FILL THE PATCH PANEL. EQUIP WITH REAR CABLE ORGANIZER.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
PANEL:HPJ24 ORGANIZER:ECMBR3
AutoCAD SHX Text
SINGLE RACK UNIT PATCH CORD ORGANIZER (PCO-1) WITH HINGED COVER.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HC119ME3N/HC119C
AutoCAD SHX Text
TWO RACK UNIT PATCH CORD ORGANIZER (PCO-2) WITH HINGED COVER.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HC2119ME3N/HC219C
AutoCAD SHX Text TELECOMMUNICATIONS GROUND BAR (TGB). 1/4"x4"x10" EQUIPPED WITH INSULATED STAND-OFFS.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HBBB14210A
AutoCAD SHX Text 2-POST RACK:7'x19" BLACK RELAY RACK EQUIPPED WITH ONE FULL-LENGTH 6" VERTICAL ORGANIZER. RELAY RACK IS TO BE CONFIGURED WITH VERTICAL & HORIZONTAL CABLE LADDER AS SHOWN ON THE DRAWINGS AND AS DESCRIBED IN THE SPECS.
AutoCAD SHX Text
ORTRONICS
AutoCAD SHX Text
19-84-T2SD-B
AutoCAD SHX Text 4-POST ADJUSTABLE RACK. PUNCHED 3/8" HOLES. EQUIP WITH TWO 6" VERTICAL ORGANIZERS. EQUIP WITH CAGE NUTS FOR 19" RACK COMPONENTS. EQUIP WIITH CABLE LADDER AS PER SPECS AND DETAILS.
AutoCAD SHX Text
ORTRONICS
AutoCAD SHX Text
19-84-SSDA2132
AutoCAD SHX Text POWER STRIP, VERTICAL, FOR BACK OF EACH RACK. SALL HAVE (6) NEMA 5-20R RECEPTACLES AND SHALL BE 18" LONG. PLUG INTO WALL OUTLET. ATTACH THE POWER STRIP TO THE BACK OF THE VERTICAL CABLE LADDER OF EACH RACK.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
PV3620A12S
AutoCAD SHX Text 24" TALL WALL MOUNT CABINET. 12 RACK UNITS. 26" DEEP. INCLUDE PLEXIGLAS FRONT DOOR AND POWER STRIP, RACK MOUNTED POWER STRIP
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HSQ2426
AutoCAD SHX Text 36" TALL WALL MOUNT CABINET. 18 RACK UNITS. 26" DEEP. INCLUDE PLEXIGLAS FRONT DOOR AND POWER STRIP, RACK MOUNTED POWER STRIP
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HSQ3626
AutoCAD SHX Text 48" TALL WALL MOUNT CABINET. 24 RACK UNITS. 26" DEEP.INCLUDE PLEXIGLAS FRONT DOOR AND POWER STRIP, RACK MOUNTED POWER STRIP
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HSQ4826
AutoCAD SHX Text
29" TALL WALL RACK. 12 RACK UNITS. 24" DEEP. INCLUDE POWER STRIP
AutoCAD SHX Text
CHATSWORTH
AutoCAD SHX Text 11790-X25
AutoCAD SHX Text
43" TALL WALL RACK. 20 RACK UNITS. 24" DEEP. INCLUDE POWER STRIP
AutoCAD SHX Text
CHATSWORTH
AutoCAD SHX Text 11791-X25
AutoCAD SHX Text
53" TALL WALL RACK. 26 RACK UNITS. 24" DEEP. INCLUDE POWER STRIP
AutoCAD SHX Text
CHATSWORTH
AutoCAD SHX Text 11807-X25
AutoCAD SHX Text
78" TALL WALL RACK. 40 RACK UNITS. 24" DEEP. INCLUDE POWER STRIP
AutoCAD SHX Text
CHATSWORTH
AutoCAD SHX Text 11792-X25
AutoCAD SHX Text POWER STRIP, RACK MOUNT, PROVIDE FOR EACH RACK OR CABINET WHERE WIFI CABLES ARE BEING TERMINATED
AutoCAD SHX Text
TRIPP LITE
AutoCAD SHX Text
PDUMH20-ISO
AutoCAD SHX Text 110 STYLE SPLICE BLOCKS. WALL MOUNTED. 16 CABLES SPLICED AT WALL FOR EXTENSION TO NEW PATCH PANEL
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
6110FTK64WL W/ CONNECTORS 6110CB4PR13 AND LABEL STRIP XPL1101OW
AutoCAD SHX Text FIBER OPTIC CABLE STOWAGE RING. WALL MOUNTED. 12" OR 24". PROVIDE AND INSTALL TO SUPPORT BEND RADIUS REQUIREMENTS OF THE FIBER CABLE`
AutoCAD SHX Text
LEVITON
AutoCAD SHX Text
24" #48900-OFR
AutoCAD SHX Text RACK MOUNT FIBER PANEL. USE WHEN TERMINATING 24 OR LESS FIBER STRANDS. PROVIDE EACH FIBER PANEL WITH "SC" SIX OR 12 PACKS AS REQUIRED FOR TERMINATION OF ALL FIBERS. PROVIDE SPLICE TRAY AND SHELF FOR FUSION SPLICES TO PIGTAILS.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
FPR3SP
AutoCAD SHX Text
RACK MOUNT SHELF. MESH BASE WITH 14" DEPTH MINIMUM
AutoCAD SHX Text
MIDDLE ATLANTIC
AutoCAD SHX Text
UFA-14.5
AutoCAD SHX Text HANDHOLE. SHALL BE 36" LONG, 24" WIDE AND 24" DEEP. EQUIP WITH EXTENSION FOR DEEPER ROUTING OF CONDUITS. EQUIP WITH A CVOER
AutoCAD SHX Text
QUAZITE
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text VERTICAL ORGANIZER FOR MOUNTING TO THE SIDE OF A RACK. WHERE THE RACK IS LESS THAN 7', CUT OFF VERTICAL ORGANIZER TO FIT RACK.
AutoCAD SHX Text
RXL
AutoCAD SHX Text
3326-BJ06
AutoCAD SHX Text
ADJUSTABLE SHELF FOR 4-POST RACK. ADJUSTABLE TO ATTACH TO ALL 4 POSTS
AutoCAD SHX Text
MIDDLE ATLANTIC
AutoCAD SHX Text
VSA-2744
AutoCAD SHX Text WALL MOUNT FIBER OPTIC PATCH PANEL. 12-24 FIBERS STRANDS. PROVIDE SPLICE PANEL AND CONNECTOR PANELS. MOVE SC CONNECTORS TO NEW PANEL.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
FCW4SP
AutoCAD SHX Text PATCH PANEL-24 PORT, EQUIPPED WITH 8-PIN MODULAR JACKS. FOR TERMINATION OF KEEFE, JPAY AND GTL CABLES. EXTEND EXISTING CABLES WITH 110 BLOCKS AND TERMINATE EXTENDED CABLES ONTO MODULAR CONNECTORS. KEEFE SHALL BE BLACK, JPAY SHALL BE WHITE, GTL SHALL BE GRAY.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
PANEL:HPJ24 ORGANIZER:ECMBR3
AutoCAD SHX Text PATCH PANEL-24 PORT, EQUIPPED WITH 8-PIN MODULAR JACKS. FOR TERMINATION OF CAMERA CABLES. EXTEND EXISTING CABLES WITH 110 BLOCKS AND TERMINATE EXTENDED CABLES ONTO MODULAR CONNECTORS. GREEN CABLES AND GREEN MODULAR CONNECTORS
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
PANEL:HPJ24 ORGANIZER:ECMBR3
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text J
AutoCAD SHX Text K
AutoCAD SHX Text L
AutoCAD SHX Text M
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text P
AutoCAD SHX Text Q
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text V
AutoCAD SHX Text
EQUIPMENT SCHEDULE, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101 ETC.
AutoCAD SHX Text
CABLE SCHEDULE, SEE COMMUNICATIONS CABLE SCHEDULE
AutoCAD SHX Text
KEYNOTES. REFER TO NOTES ON THE SHEET FOR ADDITIONAL INFORMATION
AutoCAD SHX Text DATA COMMUNICATIONS OUTLET CONNECTIVITY CODE. X IS A 1 THRU 99. SEE TC7XX SHEETS FOR SPECIFIC REQUIREMENTS. XXXX NOTES THAT THE CABLE IS FOR A SPECIFIC USE
AutoCAD SHX Text
INSTALL NEW WIRELESS ACCESS POINT. SEE DETAILS AND SPREADSHEET
AutoCAD SHX Text
INSTALL NEW EXTERIOR WIRELESS ACCESS POINT. SEE DETAILS AND SPREADSHEET
AutoCAD SHX Text
INSTALL NEW EXTERIOR WIRELESS ACCESS POINT. SEE DETAILS AND SPREADSHEET
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WAP-X
AutoCAD SHX Text X
AutoCAD SHX Text
XXXX
AutoCAD SHX Text
WAP-E2
AutoCAD SHX Text
WAP-E3
AutoCAD SHX Text
BLDG XX
AutoCAD SHX Text W
AutoCAD SHX Text X
AutoCAD SHX Text Y
AutoCAD SHX Text Z
AutoCAD SHX Text
AA
AutoCAD SHX Text
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text sheet title
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
WI-FI CABLING INFRASTRUCTURE
AutoCAD SHX Text
BELLAMY CREEK CORRECTIONAL FACILITY
AutoCAD SHX Text
IONIA, MICHIGAN
AutoCAD SHX Text 01/27/25
AutoCAD SHX Text
ISSUED FOR BID
AutoCAD SHX Text 472ElectronicComm
AutoCAD SHX Text 1065_43
AutoCAD SHX Text Y17084
AutoCAD SHX Text
472/17032.RWG
AutoCAD SHX Text 02/20/25
AutoCAD SHX Text
ADDENDUM 01
TC708
BELLAMY CREEK RACK LAYOUTS
DORMITORY A COMM ROOM D32
TC708
BELLAMY CREEK RACK LAYOUTS
HOUSING UNIT C COMM ROOM HC3
TC708
BELLAMY CREEK RACK LAYOUTS
HOUSING UNIT 1 COMM ROOM H1
TC708
BELLAMY CREEK RACK LAYOUTS
HOUSING UNIT 2 COMM ROOM H2
TC708
BELLAMY CREEK RACK LAYOUTS
HOUSING UNIT 5 COMM ROOM H5
TC708
BELLAMY CREEK RACK LAYOUTS
HOUSING UNIT 3 COMM ROOM H3
TC708
BELLAMY CREEK RACK LAYOUTS
HOUSING UNIT 4 COMM ROOM H4
GENERAL RACK NOTES KEYED RACK NOTES
TC708
RACK LAYOUTS
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
L A
TC
H
, R A
, N C
A R
B , D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
C om m te ch
D es ig n
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BELLAMY CREEK DORMITORY A COMM ROOM D3 PPD WALL CABINET D3-1
AutoCAD SHX Text
POWER STRIP
AutoCAD SHX Text
12 PORT GTL SWITCH
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT C COMM ROOM HC PPD WALL CABINET HC-1
AutoCAD SHX Text
12 PORT DTMB PANEL
AutoCAD SHX Text
12 PORT DTMB SWITCH
AutoCAD SHX Text
JPAY
AutoCAD SHX Text
ON WALL
AutoCAD SHX Text
12 PORT GTL SWITCH
AutoCAD SHX Text
24 PORT CAM SWITCH
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
ROUTER
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
ROUTER
AutoCAD SHX Text
UPS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PAGING EQUIPMENT
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 1 COMM ROOM H1 PA WALL CABINET H1-1
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 1 COMM ROOM H1 PPD WALL RACK H1-2
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
12 PORT ENET SWITCH
AutoCAD SHX Text
ENET SWITCH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
POWER STRIP
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
TRIPP-LITE
AutoCAD SHX Text
12 PORT GTL SWITCH
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 1 COMM ROOM H1 PPD WALL RACK H1-3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PAGING EQUIPMENT
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 2 COMM ROOM H2 PA WALL CABINET H2-1
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
12 PORT ENET SWITCH
AutoCAD SHX Text
KEEFE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
48 PORT CAT-6 SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
TRIPP-LITE
AutoCAD SHX Text
12 PORT GTL SWITCH
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
POWER STRIP
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
48 PORT CAT-6 SWITCH
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 2 COMM ROOM H2 PPD WALL RACK H2-2
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 2 COMM ROOM H2 PPD WALL RACK H2-3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PAGING EQUIPMENT
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 5 COMM ROOM H5 PA WALL CABINET H5-1
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TRIPP-LITE
AutoCAD SHX Text
12 PORT GTL SWITCH
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
ENET SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text
POWER STRIP
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
UPS
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 5 COMM ROOM H5 PPD WALL RACK H5-2
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 5 COMM ROOM H5 PPD WALL RACK H5-3
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PAGING EQUIPMENT
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 3 COMM ROOM H3 PA WALL CABINET H3-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TRIPP-LITE
AutoCAD SHX Text
12 PORT GTL SWITCH
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 3 COMM ROOM H3 PPD WALL RACK H3-2
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 3 COMM ROOM H3 PPD WALL RACK H3-3
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
12 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text
POWER STRIP
AutoCAD SHX Text
UPS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PAGING EQUIPMENT
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 4 COMM ROOM H4 PA WALL CABINET H4-1
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TRIPP-LITE
AutoCAD SHX Text
12 PORT GTL SWITCH
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 4 COMM ROOM H4 PPD WALL RACK H4-3
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 4 COMM ROOM H4 PPD WALL RACK H4-2
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
ENET SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text
POWER STRIP
AutoCAD SHX Text
UPS
AutoCAD SHX Text
1. VERIFY RACK EQUIPMENT AND SPACE IN THE RACK PRIOR TO VERIFY RACK EQUIPMENT AND SPACE IN THE RACK PRIOR TO INSTALLATION OF CABLES. 2. MOVE EXISTING PANELS AND OTHER EQUIPMENT UP OR DOWN AS MOVE EXISTING PANELS AND OTHER EQUIPMENT UP OR DOWN AS REQUIRED TO FIT THE NEW PATCH PANELS AND SWITCHES. 3. OWNER SHALL PROVIDE AND INSTALL ALL PATCH CABLES FOR FIBER OWNER SHALL PROVIDE AND INSTALL ALL PATCH CABLES FOR FIBER AND WAP CABLES AT THE RACKS AND ETHERNET SWITCH. 4. CONTRACTOR SHALL PROVIDE AND INSTALL CAT-6A PATCH CABLES AT CONTRACTOR SHALL PROVIDE AND INSTALL CAT-6A PATCH CABLES AT EACH WAP. 5. AT EACH RACK WHERE WAP CABLES ARE BEING INSTALLED THE AT EACH RACK WHERE WAP CABLES ARE BEING INSTALLED THE CONTRACTOR SHALL INCLUDE TIME TO ORGANIZER EXISTING CABLING AND POWER CORDS. ATTACH EXISTING CABLES TO THE CABLE LADDER AND TO THE WALL. GROUP WITH VELCRO TIES. 6. ORGANIZE ALL POWER CABLES THAT SERVE ITEMS IN THE RACK WHERE ORGANIZE ALL POWER CABLES THAT SERVE ITEMS IN THE RACK WHERE WAP CABLES ARE BEING INSTALLED. MOVE POWER STRIPS TO THE RACK AND NEATLY ROUTE ALL POWER CORDS 7. WHEN DIRECTED TO MOVE A RACK OR ROTATE A RACK, CONTRACTOR WHEN DIRECTED TO MOVE A RACK OR ROTATE A RACK, CONTRACTOR SHALL REMOVE EXISTING BOLTS FROM THE FLOOR AND SHALL INSTALL NEW BOLTS TO ATTACH RACK TO FLOOR AT NEW LOCATION
AutoCAD SHX Text PROVIDE VERTICAL SUPPORT OF CABLES AS THEY ROUTE FROM THE CEILING TO THE RACK. INSTALL 12" CABLE LADDER FROM RACK TO CEILING OR WALL. SUPPORT CABLE LADDER AT CEILING AND RACK WITH UNISTRUT ETC. SEE DETAILS ON TC705/3 OWNER TO INSTALL CAT-6A PATCH CABLES FROM CAT-6A PANEL TO THE WIFI SWITCH IN EACH RACK. LABEL EACH PORT IN THE PATCH PANEL WITH THE WAP NUMBER. INSTALL STICKER THAT IS LASER PRINTED AT JACK IN PANEL. SEE NEW PANEL LABELING DETAILS. INSTALL POWER STRIP. CONNECT TO OUTLET INSTALLED AS PART OF THIS PROJECT. SEE ELECTRICAL DRAWINGS FOR CIRCUIT MOVE EXISTING CABLES. REMOVE EXISTING DTMB CABLES FROM PANEL ON THE WALL. RE-ROUTE TO PATCH PANEL IN RACK. TERMINATE EXISTING DTMB CABLES. SEE INDIVIDUAL RACK LAYOUTS FOR CABLE QUANTITY. PROVIDE NEW PATCH PANEL WITH BLUE CAT-6 JACKS FOR CABLE TERMINATION. SPLICE EXISTING CABLES. UNTERMINATE EXISTING DTMB CABLES FROM PATCH PANEL. TERMINATE ON 110 BLOCKS. SPLICE NEW CAT-6 CABLES FROM 110 BLOCK TO NEW PATCH PANEL IN RACK. SEE TC705/2 FOR SPLICE AND EXTENSION DETAIL. SEE RACK DETAILS FOR QUANTITY OF CABLES TO EXTEND. INSTALL GROUND BAR. CONNECT TO ELECTRICAL PANEL GROUND. SEE DETAIL ON TC701/4 . INSTALL A VERTICAL ORGANIZER TO THE SIDE OF THE RACK. CONNECT RACK TO EXISTING GROUND BAR IN THIS ROOM.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text T
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text
SHELF
AutoCAD SHX Text U
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text
24 PORT DTMB PANEL
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
12 CABLES
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text A
AutoCAD SHX Text
SEE DETAIL TC709/3 FOR RACK AND CABLE REQUIREMENTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SEE DETAIL TC709/3 FOR RACK AND CABLE REQUIREMENTS
AutoCAD SHX Text
SEE DETAIL TC709/3 FOR RACK AND CABLE REQUIREMENTS
AutoCAD SHX Text
SEE DETAIL TC709/3 FOR RACK AND CABLE REQUIREMENTS
AutoCAD SHX Text
SEE DETAIL TC709/3 FOR RACK AND CABLE REQUIREMENTS
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text sheet title
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
WI-FI CABLING INFRASTRUCTURE
AutoCAD SHX Text
BELLAMY CREEK CORRECTIONAL FACILITY
AutoCAD SHX Text
IONIA, MICHIGAN
AutoCAD SHX Text 01/27/25
AutoCAD SHX Text
ISSUED FOR BID
AutoCAD SHX Text 472ElectronicComm
AutoCAD SHX Text 1065_43
AutoCAD SHX Text Y17084
AutoCAD SHX Text
472/17032.RWG
AutoCAD SHX Text 02/20/25
TC709
BELLAMY CREEK RACK LAYOUTS
HOUSING UNIT 6 COMM ROOM H6
TC709
BELLAMY CREEK RACK LAYOUTS
HOUSING UNIT 7 COMM ROOM H7
GENERAL RACK NOTES KEYED RACK NOTES
TC709
BELLAMY CREEK HOUSING UNITS 1 THRU 7
NEW AND RELOCATED RACKS -TYPICAL
GENERAL HOUSING UNIT NOTES
TC709
RACK LAYOUTS
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
L A
TC
H
, R A
, N C
A R
B , D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
C om m te ch
D es ig n
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PAGING EQUIPMENT
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 6 COMM ROOM H6 PA WALL CABINET H6-1
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TRIPP-LITE
AutoCAD SHX Text
12 PORT GTL SWITCH
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
ENET SWITCH
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text
POWER STRIP
AutoCAD SHX Text
UPS
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 6 COMM ROOM H6 PPD WALL RACK H6-2
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 6 COMM ROOM H6 PPD WALL RACK H6-3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PAGING EQUIPMENT
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 7 COMM ROOM H7 PA WALL CABINET H7-1
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TRIPP-LITE
AutoCAD SHX Text
12 PORT GTL SWITCH
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
PHONE
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
ENET SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text
POWER STRIP
AutoCAD SHX Text
UPS
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 7 COMM ROOM H7 PPD WALL RACK H7-2
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 7 COMM ROOM H7 PPD WALL RACK H7-3
AutoCAD SHX Text
1. VERIFY RACK EQUIPMENT AND SPACE IN THE RACK PRIOR TO VERIFY RACK EQUIPMENT AND SPACE IN THE RACK PRIOR TO INSTALLATION OF CABLES. 2. MOVE EXISTING PANELS AND OTHER EQUIPMENT UP OR DOWN AS MOVE EXISTING PANELS AND OTHER EQUIPMENT UP OR DOWN AS REQUIRED TO FIT THE NEW PATCH PANELS AND SWITCHES. 3. OWNER SHALL PROVIDE AND INSTALL ALL PATCH CABLES FOR FIBER OWNER SHALL PROVIDE AND INSTALL ALL PATCH CABLES FOR FIBER AND WAP CABLES AT THE RACKS AND ETHERNET SWITCH. 4. CONTRACTOR SHALL PROVIDE AND INSTALL CAT-6A PATCH CABLES AT CONTRACTOR SHALL PROVIDE AND INSTALL CAT-6A PATCH CABLES AT EACH WAP. 5. AT EACH RACK WHERE WAP CABLES ARE BEING INSTALLED THE AT EACH RACK WHERE WAP CABLES ARE BEING INSTALLED THE CONTRACTOR SHALL INCLUDE TIME TO ORGANIZER EXISTING CABLING AND POWER CORDS. ATTACH EXISTING CABLES TO THE CABLE LADDER AND TO THE WALL. GROUP WITH VELCRO TIES. 6. ORGANIZE ALL POWER CABLES THAT SERVE ITEMS IN THE RACK WHERE ORGANIZE ALL POWER CABLES THAT SERVE ITEMS IN THE RACK WHERE WAP CABLES ARE BEING INSTALLED. MOVE POWER STRIPS TO THE RACK AND NEATLY ROUTE ALL POWER CORDS 7. WHEN DIRECTED TO MOVE A RACK OR ROTATE A RACK, CONTRACTOR WHEN DIRECTED TO MOVE A RACK OR ROTATE A RACK, CONTRACTOR SHALL REMOVE EXISTING BOLTS FROM THE FLOOR AND SHALL INSTALL NEW BOLTS TO ATTACH RACK TO FLOOR AT NEW LOCATION
AutoCAD SHX Text PROVIDE VERTICAL SUPPORT OF CABLES AS THEY ROUTE FROM THE CEILING TO THE RACK. INSTALL 12" CABLE LADDER FROM RACK TO CEILING OR WALL. SUPPORT CABLE LADDER AT CEILING AND RACK WITH UNISTRUT ETC. SEE DETAILS ON TC705/3 OWNER TO INSTALL CAT-6A PATCH CABLES FROM CAT-6A PANEL TO THE WIFI SWITCH IN EACH RACK. LABEL EACH PORT IN THE PATCH PANEL WITH THE WAP NUMBER. INSTALL STICKER THAT IS LASER PRINTED AT JACK IN PANEL. SEE NEW PANEL LABELING DETAILS. INSTALL POWER STRIP. CONNECT TO OUTLET INSTALLED AS PART OF THIS PROJECT. SEE ELECTRICAL DRAWINGS FOR CIRCUIT MOVE EXISTING CABLES. REMOVE EXISTING DTMB CABLES FROM PANEL ON THE WALL. RE-ROUTE TO PATCH PANEL IN RACK. TERMINATE EXISTING DTMB CABLES. SEE INDIVIDUAL RACK LAYOUTS FOR CABLE QUANTITY. PROVIDE NEW PATCH PANEL WITH BLUE CAT-6 JACKS FOR CABLE TERMINATION. SPLICE EXISTING CABLES. UNTERMINATE EXISTING DTMB CABLES FROM PATCH PANEL. TERMINATE ON 110 BLOCKS. SPLICE NEW CAT-6 CABLES FROM 110 BLOCK TO NEW PATCH PANEL IN RACK. SEE TC705/2 FOR SPLICE AND EXTENSION DETAIL. SEE RACK DETAILS FOR QUANTITY OF CABLES TO EXTEND. INSTALL GROUND BAR. CONNECT TO ELECTRICAL PANEL GROUND. SEE DETAIL ON TC701/4 . INSTALL A VERTICAL ORGANIZER TO THE SIDE OF THE RACK. CONNECT RACK TO EXISTING GROUND BAR IN THIS ROOM.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIBER PANEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TRIPP-LITE
AutoCAD SHX Text
12 PORT GTL SWITCH
AutoCAD SHX Text
24 PORT GTL PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
24 PORT ENET SWITCH
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT X COMM ROOM HX PPD WALL RACK HX-3
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT X COMM ROOM HX PPD WALL RACK HX-2
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
24 PORT CAT-6 PANEL
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
ENET SWITCH
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text
POWER STRIP
AutoCAD SHX Text
UPS
AutoCAD SHX Text
FIBER PANEL TO REMAIN
AutoCAD SHX Text
FIBER STOWAGE RING EXISTING
AutoCAD SHX Text
GND BAR
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text G
AutoCAD SHX Text
BELLAMY CREEK HOUSING UNIT 4 COMM ROOM H4 NEW WALL RACK H4-2
AutoCAD SHX Text
POWER STRIP
AutoCAD SHX Text Q
AutoCAD SHX Text
FIBER PANEL 12 MM
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text A
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text REMOVE WALL RACKS. MOVE EXISTING EQUIPMENT INTO NEW 4-POST OR RELOCATED HX-3 RACK.RACK. CONSOLIDATE EQUIPMENT IN THE NEW WALL RACK.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIBER PANEL TO REMAIN
AutoCAD SHX Text
FIBER STOWAGE RING TO REMAIN RELOCATE TO ALLOW CABLE LADDER TO BE INSTALLED
AutoCAD SHX Text
AutoCAD SHX Text
24 CABLES
AutoCAD SHX Text
DTMB ETHERNET SWITCH
AutoCAD SHX Text
PCO - 1
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
48 PORT CAM SWITCH
AutoCAD SHX Text C
AutoCAD SHX Text
24 PORT CAM PANEL
AutoCAD SHX Text
36 CABLES
AutoCAD SHX Text
AutoCAD SHX Text
UTILIZE GREEN CABLES
AutoCAD SHX Text
EXISTING TO BE RELOCATED
AutoCAD SHX Text
EXISTING TO BE RELOCATED
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
24 PORT PPD PANEL
AutoCAD SHX Text
24 PORT PPD SWITCH
AutoCAD SHX Text
24 PORT PPD PANEL
AutoCAD SHX Text EXISTING TO BE RELOCATED. CABLES ARE LONG ENOUGH TO EXTEND TO NEW RACK. NO SPLICING OR RETERMINATION REQUIRED.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text INSTAL RACK ON END WALL. FRONT SHOWN ON THIS DETAIL FOR EQUIPMENT TO BE LOCATED IN THE RACK
AutoCAD SHX Text INSTALL NEW WALL MOUNT FIBER PANEL FOR EXISTING 12 STRAND MM FIBER. RELOCATE EXISTING FIBER INTO NEW PANEL. LABEL EXTERIOR OF PANEL
AutoCAD SHX Text INSTALL NEW 110 BLOCKS FOR SPLICING THE DTMB CABLING AND CAMERA CABLING. SEE RACK LAYOUT TO RIGHT FOR CABLE QUANTITIES
AutoCAD SHX Text
EXISTING PPD CABLE COIL
AutoCAD SHX Text
EXISTING PPD CABLE COIL
AutoCAD SHX Text
EXISTING PPD CABLE COIL
AutoCAD SHX Text
REROUTE EXISTING PPD CABLING TO NEW RACK. NO SPLICING REQUIRED
AutoCAD SHX Text Y
AutoCAD SHX Text
PROVIDE AND INSTALL 62.5 MM SC TO LC FIBER OPTIC PATCH CORDS. -KEEFE -JPAY -GTL
AutoCAD SHX Text SPLICE AND EXTEND KEEFE AND GTL AND JPAY CABLES TO RELOCATED WALL RACK. ASSUME 24 TOTAL CABLES
AutoCAD SHX Text
PROVID 48" MINIMUM SLACK LOOP OF CAT-6A WAP CABLES.
AutoCAD SHX Text
INSTALL NEW 12" CABLE LADDER FROM NEW RACK TO WALL. SUPPORT FROM WALL
AutoCAD SHX Text
POWER STRIP
AutoCAD SHX Text Q
AutoCAD SHX Text
AutoCAD SHX Text
SHELF
AutoCAD SHX Text U
AutoCAD SHX Text
24 PORT CAT-6 WIFI
AutoCAD SHX Text C
AutoCAD SHX Text Z
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
WALL
AutoCAD SHX Text
TO GND BAR
AutoCAD SHX Text
TO GND BAR
AutoCAD SHX Text
SHELF
AutoCAD SHX Text X
AutoCAD SHX Text
SHELF
AutoCAD SHX Text X
AutoCAD SHX Text
SHELF
AutoCAD SHX Text U
AutoCAD SHX Text
SHELF
AutoCAD SHX Text U
AutoCAD SHX Text
EXTENDED DTMB AND CAMERA SYSTEM CABLES ON CABLE LADDER
AutoCAD SHX Text
PROVIDE AND INSTALL SM LC TO LC FIBER OPTIC PATCH CORD FOR -PPD
AutoCAD SHX Text
PROVIDE AND INSTALL 62.5 MM SC TO LC FIBER OPTIC PATCH CORDS. -DTMB -CAMERAS
AutoCAD SHX Text
CONNECT TO EXISTING GROUDN BAR WITH 2-HOLE COMPRESSION CONNECTOR
AutoCAD SHX Text
EXISTING GROUND BAR
AutoCAD SHX Text
EXISTING CABLES. TERMINATE TO 110 BLOCKS TO EXTEND
AutoCAD SHX Text
UTILIZE BLUE CABLES
AutoCAD SHX Text
INSTALL FOR EXTENDED CAT-6 CABLES FROM -KEEFE -JPAY -GTL
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
KEFEE
AutoCAD SHX Text
JPAY
AutoCAD SHX Text
JPAY
AutoCAD SHX Text
GTL
AutoCAD SHX Text
GTL
AutoCAD SHX Text
EXISTING HOUSING UNIT COMM ROOM LAYOUT. TYPICAL OF ALL HOUSING UNITS
AutoCAD SHX Text
REVISED HOUSING UNIT COMM ROOM LAYOUT. TYPICAL OF ALL HOUSING UNITS
AutoCAD SHX Text
1. CONTRACTOR SHALL MOVE AND EXTEND CABLES AS NOTED TO CONTRACTOR SHALL MOVE AND EXTEND CABLES AS NOTED TO FACILITATE RENOVATION OF THIS AREA. 2. INSTALL NEW 4 POST RACK. SEE DETAILS ON SHEET TC705 /4 FOR INSTALL NEW 4 POST RACK. SEE DETAILS ON SHEET TC705 /4 FOR CABLE LADDER REQUIREMENTS. 3. MOVE RACK MOUNT FIBER INTO NEW WALL MOUNT PANEL. PROVIDE MOVE RACK MOUNT FIBER INTO NEW WALL MOUNT PANEL. PROVIDE NEW FIBER PATCH CABLES TO EXTEND SIGNAL TO NEW SWITCH LOCATIONS. 4. TERMINATE AND SPLICE CABLES NOTED ON CAT-6 RATED 110 TERMINATE AND SPLICE CABLES NOTED ON CAT-6 RATED 110 BLOCKS. PROVIDE NEW CABLES TO EXTEND FROM 110 BLOCKS TO NEW PANELS. 5. MOVE EXISTING PPD CABLES AND PANELS INTO NEW 4 POST RACK. MOVE EXISTING PPD CABLES AND PANELS INTO NEW 4 POST RACK. 6. RELOCATE EXISTING WALL RACK TO END WALL OF COMM ROOM. RELOCATE EXISTING WALL RACK TO END WALL OF COMM ROOM. EXTEND CABLES INTO NEW PANEL.
This is the start of the file's text. The full file is on GovTribe.