436 QASP MRI SERVICES 2021 - Final.docx

DOCX document 65 KB Posted

Attached to
Q522--Mobile MRI Patient Scan Services On-site at Montana VAHCS, contractor-provided trailer and services
Solicitation number
36C25922Q0054
Issued by

View the file

Other files

File Type Posted
36C25922Q0054 0006.docx DOCX document
36C25922Q0054 0005.docx DOCX document
36C25922Q0054 0004.docx DOCX document
36C25922Q0054 0003.docx DOCX document
36C25922Q0054 0002.docx DOCX document
36C25922Q0054 0001.docx DOCX document
VHA Directive 1105_05_D_2018-05-29.pdf PDF
VA MOU ISA Approved Final Template-09092020.doc DOC document
36C25922Q0054.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Quality Assurance Surveillance Plan (QASP)

The contractor will be evaluated in accordance with the following:

1. PURPOSE

This Quality Assurance Surveillance Plan (QASP) provides a systematic method to evaluate performance for the stated contract. This QASP explains the following:

· What will be monitored.

· How monitoring will take place.

· Who will conduct the monitoring.

· How monitoring efforts and results will be documented.

This QASP does not detail how the contractor accomplishes the work. Rather, the QASP is created with the premise that the contractor is responsible for management and quality control actions to meet the terms of the contract. It is the Government’s responsibility to be objective, fair, and consistent in evaluating performance.

This QASP is a “living document” and the Government may review and revise it on a regular basis. However, the Government shall coordinate changes with the contractor through contract modification. Copies of the original QASP and revisions shall be provided to the contractor and Government officials implementing surveillance activities.

2. GOVERNMENT ROLES AND RESPONSIBILITIES

The following personnel shall oversee and coordinate surveillance activities.

a) Contracting Officer (CO) – The CO shall ensure performance of all necessary actions for effective contracting, ensure compliance with the contract terms, and shall safeguard the interests of the United States in the contractual relationship. The CO shall also assure that the contractor receives impartial, fair, and equitable treatment under this contract. The CO is ultimately responsible for the final determination of the adequacy of the contractor’s performance.

Assigned CO: Monica Gary

Organization or Agency: Department of Veterans Affairs, Office of Acquisition and Materials

b) Contracting Officer’s Technical Representative (COR) – The COR is responsible for technical administration of the contract and shall assure proper Government surveillance of the contractor’s performance. The COR shall keep a quality assurance file. The COR is not empowered to make any contractual commitments or to authorize any contractual changes on the Government’s behalf.

c) Assigned COR: Jefferson Trent Sickles, Diagnostic Imaging Administrative Officer, (406) 447-7605 Comment by Buffington, Douglas D.: Removed hard return and added return at end of line.

3. CONTRACTOR REPRESENTATIVES

The following employees of the contractor serve as the contractor’s program manager for this contract.

4. PERFORMANCE STANDARDS

Performance standards define desired services. The Government performs surveillance to determine if the contractor exceeds, meets or does not meet these standards.

The Performance Requirements are listed below in Section 6. The Government shall use these standards to determine contractor performance and shall compare contractor performance to the standard and assign a rating.

5. INCENTIVES/DEDUCTIONS

The Government shall use past performance as incentives. Incentives shall be based on exceeding, meeting, or not meeting performance standards.

6. METHODS OF QA SURVEILLANCE

Various methods exist to monitor performance. The COR shall use the surveillance methods listed below in the administration of this QASP.

Measures
Performance

Requirement

Standard
Acceptable Quality Level
Surveillance

Method

Incentive
Disincentive

(Deduct)

1. Patient Access
MRI technologist must be on site between the hours of 8am to 4:30pm Monday through Friday.
Qualified personnel are available and in location as needed/necessary/required? to properly perform tasks as specified.
No more than one (41) unplanned absence per year.Comment by Buffington, Douglas D.: Typo
Direct surveillance. Periodic sampling of time and attendance sheets
Favorable contractor performance evaluation.
Unfavorable contractor performance evaluation
2. Equipment Maintenance and Service.
Contractor is required to maintain a Service Maintenance Agreement which guarantees FSE coverage Monday through Friday 8am-9pm with onsite response time of four hours or less. Repair part delivery guaranteed next day delivery NLT 11am. 95% uptime commitment.
Contractor purchases and maintains a fully funded SMA which satisfies all the stated performance standards.
100% compliance is required.Comment by Buffington, Douglas D.: This becomes pass/fail, should a lowe % be applied to allow for weather or Acts of God?Comment by Sickles, Jefferson Trent.: The standard is maintaining a SMA for the equipment – no exceptions! 95% uptime and four hour response time give some latitude and are consistent with other SMAs in place.
Direct surveillance. Periodic sampling of maintenance records.
Favorable contractor performance evaluation.
Unfavorable contractor performance evaluation
3. Mandatory Training and QA activities
Contractor completes all required training and participates in all quality assurance/ management activities requested by the Chief of Diagnostic Imaging and/or the Chief of Staff.Comment by Buffington, Douglas D.: These trainings should be outlined/mandated in the work requirement. QASP should be method to review compliance.Comment by Sickles, Jefferson Trent.: In that case we may need to restrict this to Mnadatory Training.Comment by Sickles, Jefferson Trent.:
Contractor will complete all required training per VAMC policy and participates in all quality assurance/ management activities requested by the Chief of Radiology and/or the Chief of Staff.Comment by Buffington, Douglas D.: Where is this outlined? We will pay for this in Overhead or other charges and should allow Contractors to know what is required oming in.Comment by Sickles, Jefferson Trent.: Refers to mandatory Privacy and Information Security training. Available at no cost to the vendor through TMSComment by Sickles, Jefferson Trent.:
100% compliance is required.Comment by Buffington, Douglas D.: Does a lower % make sense? Should this be more like 95%/98%?Comment by Sickles, Jefferson Trent.: I can live with 95%
Periodic Sampling. Contractor to provide documented evidence for training and direct observation of compliance of quality assurance/ management activities.
Favorable contractor performance evaluation.
Unfavorable contractor performance evaluation.

Suspension or termination of all physical or electronic access privileges and removal from contract until such time as training is complete.

4. Privacy, Confidentiality and HIPAA
Contractor complies with all laws, regulations, policies, and procedures relating to Privacy, Confidentiality and HIPPA.
Zero breaches of privacy or confidentiality
100%Comment by Buffington, Douglas D.: Regualtory requirements
Periodic sampling. Contractor to provide evidence of annual training required by VAMC, reports violations per policy
Favorable contractor performance evaluation.

Immediate removal from contract

5. Maintains licensing, registration, and certification
All licensing, registrations, certifications and BLS shall be current.
All (100%) licensing, registration(s) and certification(s) for contract physician (s) shall be provided as they are renewed. Licensing and registration information kept current.
Contract Provider records will be kept 100% up-to-dateComment by Buffington, Douglas D.: Regulatory requirements
Periodic Sampling and Random Sampling
Favorable contractor performance evaluation.
Unfavorable contractor performance evaluation
6. Qualifications of Key Personnel
All contract technologists will be ARRT certified in MRI and maintain current registry.
All (100%) technologists are ARRT registered.
100% complianceComment by Buffington, Douglas D.: Regulatory Requirement
Random inspection of qualification documents
Favorable contractor performance evaluation
Unfavorable contractor performance evaluation. Removal from contract until such time the contract technologist meets qualification standard.
7. Patient Safety
Patient safety incidents shall be reported using Patient Safety Report. All incidents reported immediately.
All (100%) of patient safety incidents are reported using Patient Safety Report within 24 hours of incident.
All (100%) of patient safety incidents are reported using Joint Patient Safety Report within 24 hours of incident. No acceptable deviationComment by Buffington, Douglas D.: Regulatory requirement
Direct observation
Favorable contractor performance evaluation
Unfavorable contractor performance evaluation.

Other performance evaluation factors will be monitored that are not quantified by numerical measurements which include: no inappropriate prescriptions; patient customer service comments; provider and Contractor relationship with hospital staff/government contracting personnel; compliance with hospital policy and procedures.

The contractor is responsible for performance of ALL terms and conditions of the contract, the elements above represent those that will be subject to ongoing reporting by the COR in accordance with this plan.

a) DIRECT OBSERVATION. 100 percent surveillance

b) PERIODIC INSPECTION. Inspections scheduled annually or as needed. Ten randomly selected patient files per inspection period.

c) VALIDATED USER/CUSTOMER COMPLAINTS. Customer complaint data is compiled quarterly and reviewed by Service Chief – any validated complaints against a Contractor that are not resolved within the required seven day period will be further investigated.

d) RANDOM SAMPLING. Patient treatment files to be reviewed will be randomly selected and cover the period of service.

e) Verification and/or documentation provided by Contractor.

7. RATINGS

Metrics and methods are designed to determine if performance exceeds, meets, or does not meet a given standard and acceptable quality level. A rating scale shall be used to determine a positive, neutral, or negative outcome. The following ratings shall be used:

EXCEPTIONAL:
Performance significantly exceeds contract requirements to the Government’s benefit.
SATISFACTORY:
Performance meets contractual requirements.
UNSATISFACTORY:
Performance does not meet contractual requirements.

8. DOCUMENTING PERFORMANCE

a) ACCEPTABLE PERFORMANCE The Government shall document positive performance. Any report may become a part of the supporting documentation for any contractual action.

b) When unacceptable performance occurs, the CO shall inform the contractor. This will normally be in writing unless circumstances necessitate verbal communication. In any case the CO shall document the discussion and place it in the contract file. When the CO determines formal written communication is required, the CO shall prepare a Contract Discrepancy Report (CDR), and present it to the contractor's program manager.

The contractor shall acknowledge receipt of the CDR in writing. The CDR will specify if the contractor is required to prepare a corrective action plan to document how the contractor shall correct the unacceptable performance and avoid a recurrence. The CDR will also state how long after receipt the contractor has to present this corrective action plan to the CO. The Government shall review the contractor's corrective action plan to determine acceptability.

Any CDRs may become a part of the supporting documentation for any contractual action deemed necessary by the CO.

9. FREQUENCY OF MEASUREMENT

a) Frequency of Measurement.

During contract performance, the COR will periodically analyze whether the negotiated frequency of surveillance is appropriate for the work being performed.

b) Frequency of Performance Assessment Meetings.

The COR shall meet with The Contractor semi-annually to assess performance and shall provide a written assessment.

SIGNED CONTRACTOR DATE

Jefferson T. Sickles, FAC-COR II DATE Diagnostic Imaging Administrative Officer

CONTRACT DISCREPANCY REPORT

1. CONTRACT NUMBER
2. REPORT NUMBER FOR THIS DISCREPANCY
3. TO: (Contracting Officer)
4. FROM: (Name of COR)

5. DATES

a. CDR PREPARED

b. RETURNED BY CONTRACTOR:
c. ACTION COMPLETE

6. DISCREPANCY OR PROBLEM (Describe in detail. Include reference to PWS Directive; attach continuation sheet if necessary.)

7. SIGNATURE OF COR
Date:
8. SIGNATURE OF CONTRACTING OFFICER
Date:
9a. TO (Contracting Officer)
9a. FROM (Contractor)

10. CONTRACTOR RESPONSE AS TO CAUSE, CORRECTIVE ACTION AND ACTIONS TO PREVENT RECURRENCE. (Cite applicable quality control program procedures or new procedures. Attach continuation sheet(s) if necessary.)

11. SIGNATURE OF CONTRACTOR REPRESENTATIVE
Date:

12. GOVERNMENT EVALUATION. (Acceptance, partial acceptance, reflection. Attach continuation sheet(s) if necessary.)

13. GOVERNMENT ACTIONS (Acceptance, partial acceptance, reflection. Attach continuation sheet(s) if necessary.)

14. CLOSE OUT

NAME
TITLE
SIGNATURE
DATE

CONTRACTOR NOTIFIED

COR

CONTRACTING OFFICER

File details come from the government source that posted it. Updated .