36C25922Q0054 A0001

5. PROJECT NUMBER (if applicable)

CODE

7.

ADMINISTERED BY

2. AMENDMENT/MODIFICATION NUMBER

CODE

6. ISSUED BY

8. NAME AND ADDRESS OF CONTRACTOR

4. REQUISITION/PURCHASE REQ. NUMBER

3. EFFECTIVE DATE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED

PAGE OF

PAGES

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED

BPA NO.

1. CONTRACT ID CODE

FACILITY CODE

CODE

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

E. IMPORTANT:

is extended,

(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE

OF YOUR

ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.

12. ACCOUNTING AND APPROPRIATION DATA

(REV. 11/2016)

is required to sign this document and return ___________ copies to the issuing office.

is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

15C. DATE SIGNED

B. THE ABOVE NUMBERE

D CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES

SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

RESULT IN REJECTION OF YOUR

OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendmen t, and is received prior to the opening hour and date specified.

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER

Contractor

16C. DATE SIGNED

14. DESCRIPTION OF AMENDMENT/MODIFICATION

16B. UNITED

STATES OF AMERICA

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER

16A. NAME AND TITLE OF

CONTRACTING OFFICER

15B. CONTRACTOR/OFFEROR

STANDARD FORM 30

PREVIOUS EDITION NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)

(If required)

(SEE ITEM 11)

(SEE ITEM 13)

(X)

CHECK

ONE

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF

SOLICITATIONS

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

(Signature of person authorized to sign) (Signature of Contracting Officer) 36C259 Department of Veterans Affairs Network Contracting Office

NCO 19

6162 South Willow Drive, Suite 300 Greenwood Village CO 80111 36C259 Department of Veterans Affairs Network Contracting Office

NCO 19

6162 South Willow Drive, Suite 300 Greenwood Village CO 80111 To all Offerors/Bidders

36C25922Q0054 12-21-2021

X X X

See CONTINUATION Page X MRI Services supporting the Montana VA Health Care System, Fort Harrison, Montana

The purpose of this Amendment is to post the Questions and Answers received and to correct the

PWS.

All other terms and conditions remain unchanged.

Monica Gary Contracting Officer

CONTINUATION PAGE

Questions and Answers:

1. Your solicitation 36C25922Q0054 requests a detachable table in the Mobile MRI space. Is this a must have requirement or would you accept a table trolley to move patients onto the MRI table? Because of space constraints we do not typically have detachable tables in our mobile MRI.

RESPONSE: Trolley system is acceptable. The PWS is updated at ITEM 4 Technical Specifications and included.

2. Will you only accept a standard mobile coach or is there room for a mobile transportable (12x60)?

RESPONSE: There is adequate space for a mobile transportable system provided the vendor is capable of removing or relocating the structure within the time constraints of the PWS. Please verify the site conditions first hand as the Government makes no guarantee of site suitability for a specific piece of equipment.

Performance Work Statement

VETERAN’S ADMINISTRATION HEALTH CARE SYSTEM,

FORT HARRISON, MONTANA

Mobile Magnetic Resonance Imaging (MRI) patient scan services for the Montana VA Health Care System (MTVAHCS) at Fort Harrison VAMC

The Montana VA Health Care System (MTVAHCS) requires a qualified contractor to provide inpatient MRI scan services in accordance with the PWS, in an efficient, cost-effective and safe manner, and in support of the VA Mission. Services are required for the period of performance and at the location outlined in this PWS.

1. CONTRACTOR PROVIDED SERVICES/EQUIPMENT

This is a non-personal services contract. The Contractor, it's employees, agents and subcontractors shall not be considered government employees for any purpose. Contractor shall furnish all labor, materials, parts, equipment, tools, shipping, transportation, mobile trailer, insurances, licenses, certifications and supervision necessary to provide services in accordance with this Performance Work Statement (PWS). The Contractor is responsible for all charges, fees, applications and procurement of all permits, licenses, registrations and certificates, pursuant to lawful application of the provision of services. For a contract of this size, scope and complexity, the successful Contractor must perform in a professional manner as recognized by commercial industry standards as good to excellent.

Price: Refer to the Price/Cost Schedule.

Period of Performance: Refer to the Price/Cost Schedule.

Location of Services: Refer to block 15, pg1, Sf1449

1. COMMENCEMENT OF SERVICES

Commencement of service date shall be coordinated with the Contracting Officer (CO). MRI scanning equipment in a trailer shall be on-site available for patient services no later than 31 MAR 2022 unless otherwise agreed to in writing with the Contracting Officer. At a minimum, an interim mobile imaging system will be provided within 30 days of award of contract until the dedicated imaging system is in place and operational.

1. THE MONTANA VA HEALTH CARE SYSTEM SHALL PROVIDE:

· Location and site prep required to connect contractor provided equipment to the local VA facility (to include utilities such as electricity*, plumbing, telephone circuit[s]**, data network connections and routers as necessary to transmit images) is the responsibility of the contractor. Site pad cross section is provided below:

· Average slope of the pavement along the long axis of the parking area is 0.17 percent and the average cross slope in that area is 0.14 percent.

· A physician and nurse if needed for cardiac studies, diabetic patients, or in case of an emergency.

· Ancillary medical services and equipment as is routinely found in the MRI modality.

· Scheduling of patients.

· All patient and 3rd party billing.

· Utilities, including electricity and telephone line, network connections and routers as necessary to transmit images.

Red Region: Location for MRI Trailer placement

Blue Region: Parking area

* In accordance to the Original Equipment Manufacturers (OEM) electrical specifications.

** Use of telephone extension while mobile unit is on site will be in order to permit personnel of the unit to make and receive telephone calls, and to facilitate the movement of patients to and from the unit. Telephone calls placed and received by the personnel of the unit on the extension shall be restricted to the appropriate free dialing areas. Long distance calls will be made with calling cards, reverse charges or to toll free numbers provided by and paid for by the contractor.

The VA shall be held responsible for housekeeping areas within the hospital facility prior to entrance of the mobile Trailer. Contractor shall be responsible for all housekeeping duties and responsibilities within the trailer itself.

1. MRI EQUIPMENT/SERVICES/SUPPLIES

The Contractor shall provide MRI services with reliable, state of the art FDA approved equipment that provides image quality meeting or exceeding that of a 1.5 Tesla System and have magnetic resonance angiogram (MRA) capability. Equipment shall support 8-16 channel receiver coils and capable of parallel imaging, diffusion/ADC.

The Contractor will provide the proper inspection and acceptance survey of all MRI systems provided through this contract. The survey must be done by an ADBR certified Medical Physicist qualified to inspect MRI systems.

The MRI machine shall be capable of performing Magnetic Resonance Angiographies and functional imaging capabilities with all necessary software, hardware and power injector needed to perform bilateral-complete leg runoff and abdominal, thoracic and cervical angiographies. In addition, Contractor care shall cover the range of services provided in a civilian medical treatment facility.

The MRI equipment shall be capable of providing a full range of exams to include but not limited to the following:

MRI Brain

MRI any joint, upper extremity

MRI/MRA Pelvis

MRA Spinal Canal

MRI Orbit, face, neck

MRI other than joint, upper extremity

MRIMRA Abdomen

MRA Spectroscopy

MRI TMJ

MRA upper extremity

MRI Lumbar Spine

MRA Head

MRI/MRA Chest

MRI any joint, lower extremity

MRI Thoracic Spine

MRA Neck

MRI Cardiac

MRI other than joint, lower extremity

MRI Cervical Spine

MRA lower extremity

THE MRI SYSTEM MUST MEET OR EXCEED THE FOLLOWING TECHNICAL SPECIFICATIONS:

· Minimum Bore Width of 70cm

· 49 Channels

· Gradient Amplitude and Slew Rate of 36/150

· Silent Scanning and/or Acoustic Reduction System technology

· Motion Correction software

· Lightweight and flexible coil system design

· Detachable exam couch or trolley system with 550-pound patient weight limit or greater

· Includes a pre-installed or free-standing MRI safe patient monitoring system rated for 5,000 Gauss, 7.2 uT B1 rms, 4W/Kg SAR, and 3T environment. This system must offer the following features:

· Wireless ECG

· Wireless SpO2

· NIBP

· CO2

· IBP

· Temperature

1. ADDITIONAL MRI MODULE UNIT/ EQUIPMENT SPECIFICATIONS

The following minimum performance characteristics of the MRI equipment are required:

· The unit(s) shall provide optimal quality images deemed technically acceptable by the on-duty VA radiologist. Images noted as unsatisfactory image quality by the radiologist shall be considered non-performance under this contract and shall be remedied within 30 days of notification.

· The mobile building/unit(s) shall be furnished, and temperature controlled to assure proper operation of the scanner without frequent calibration and provide for patient comfort.

· The mobile building/unit(s) shall meet all federal, state and local fire and safety requirements.

· Telecommunications: The mobile unit(s) shall be equipped with outlet jack connections capable of transmitting data and voice through Government provided category five (CAT 5) cable and dual pair phone cable. The Government shall provide the connection required for the transmission of images, data and voice.

· The mobile unit shall support DICOM Modality Worklist (DMWL), for future use.

· The mobile unit shall be able to export DICOM images to at least one destination.

· System shall have been approved by the FDA and meets or exceeds minimal standards for the type of equipment being provided as defined herein.

· System shall have the ability to create, store and export DICOM, JPEG and MPEG file formats.

· The mobile unit shall be equipped with CD-R/DVD burning capabilities as a backup to network transfer of data

· The mobile unit shall be equipped with an Image Analysis Station for image registration quality assurance.

· The mobile unit shall be equipped with an IV contrast injector.

· The mobile unit shall be equipped with a programmable injector with pressure monitor having the following capabilities:

Scan delay Multiphase option Protocol storing Pause hold functionality

· The contractor’s MRI unit shall provide the space sufficient and appropriate equipment for conducting cardiopulmonary resuscitation if necessary.

· The unit shall be ADA compliant and the contractor will provide a fully enclosed ADA approved walkway/access to the MRI system which provides adequate shelter from inclement weather.

· The unit shall include an Intercom system between the control room and scanning room.

1. SCHEDULE/ANCILLARY SUPPLIES/PERSONNEL

The contractor shall provide all labor, materials, equipment, maintenance, personnel and supervision necessary to operate the MRI unit for a period of nine hours per day Monday through Friday from 8:00am to 5:00 pm excluding Federal Holidays. The VA reserves the right to schedule as many exams per day as possible to assure patient needs are met. The contractor is responsible to perform any set-up procedures or shut down procedures outside of these hours. Any changes to this schedule shall be approved by the Contracting Officer in writing.

MRI technologists and VA radiologists will require applications training specific to the MRI system provided. Contractor will provide remote service and applications support as allowed by VHA policy and directives.

The VA shall provide the following ancillary supplies; Gadolinium Based Contrast Agents (GBCA), latex-free exam gloves, needles, syringes, and expendable medical supplies to perform MRI services. The contractor shall procure and provide all other supplies/materials as required to perform MRI procedures.

The contractor shall provide all personnel required to provide MRI exams. These personnel shall include, but not be limited to the technologists and ancillary support staff. The type of personnel and number of personnel shall be determined by the contractor and shall be based on VA requirements/patient schedule. The contractor is responsible for meeting the mandatory “two deep” technologist requirement specified in VHA Directive 1105.05.

The contractor shall provide an adequate number of MRI technologists required to perform services five days a week, nine hours per day. If the VA changes the schedule, the contractor shall adjust the number of technologists accordingly to provide the requested services. The MRI technologists shall have the required Montana State license/certification to provide requested services, be certified by the American Registry of Radiologic Technologists with additional certification for performing MRI examinations and be experienced in Magnetic Resonance Angiographies (MRA). The technologist shall be trained and qualified to perform venipuncture, assess IV patency, and administer contrast media/radioisotopes according to VA procedures and protocols. The contractor shall provide for a backup plan for technologist coverage in the event of illness, family emergency, or other unanticipated events.

1. SUPPLIES

The Contractor shall be solely responsible for the procurement, receipt, dispensing, administration, and safekeeping of all supplies and medications/drugs in accordance with Contractor’s license, state and NRC regulations.

· Unit shall meet ADA access standards.

· Unit shall have Intercom system between the control room and scanning room.

· Contractor shall provide coach specific requirements for access, docking pad and covered enclosure with the solicitation. Contractor or designee will be afforded the opportunity to conduct a site visit in advance of contract award to consult with VA supplied engineers.

· The mobile unit(s) shall provide images with consistently high technical quality to be assessed/judged by VA employed experts. Poor image quality, as judged by VA employed experts, will be considered non-performance under this contract and must be remedied within 30 days of notification.

· The mobile unit(s) shall be ready for use regardless of outside environmental conditions.

· The mobile unit(s) shall maintain a temperature to assure proper operation of the scanner without frequent calibration and provide for patient comfort.

· The mobile unit(s) shall meet all federal, state and local fire and safety requirements.

· Telecommunications: The mobile unit(s) shall be equipped with outlet jack connections capable of transmitting data and voice through Government provided Category five (5) cable and dual pair phone cable. The Government will provide the connection required for the transmission of images, data and voice.

· The mobile unit shall support DICOM Modality Worklist (DMWL), for future use.

· The mobile unit shall be able to export DICOM images to at least one destination.

· System shall have been approved by the FDA and meets or exceeds minimal standards for the type of equipment being provided as defined herein.

· Contractor shall be held responsible for any damages, which may be done to VA property during delivery, hookup, and/or removal of equipment at the site. Any damages caused by the Contractor will be remediated/repaired at the Contractor’s expense to the satisfaction of the facility Chief of Engineering.

1. MOBILE MRI TRAILER LOGISTICS

· The VA shall provide a designated docking pad area, standard 480V electrical connection hook up, CAT 5 data connection, and phone connection. There are no dedicated potable water or sewer service available at the dock area. There are freshwater spigots located near the parking pad. Any additional costs as a result of the Contractor’s failure to confirm the onsite infrastructure and specifications shall be the responsibility of the contractor.

· The contractor shall be responsible for contacting the VA Police at the site of service at the time of arrival, in which the contractor shall need access to both the building and data port connections for that day’s operation. The contractor shall also be responsible for contacting the site VA Police at the closing of each workday to ensure that both the building and the data port connections are secured.

- Communications systems shall be operational before commencement of services.

- The Contractor’s mobile trailer shall be parked and leveled no more than 12” from docking pad ramp. Contractor shall be responsible for leveling of the trailer at location designed by the VA to assure safety of all VA patients. Appropriate utilities shall be connected for proper warm up of all on board systems.

- Proper installation/staging of the Contractor’s furnished equipment including the mobile trailer must be completed in accordance with industry standards, all OSHA regulations, and applicable manufacturer’s recommendations. The above must be completed prior to commencement of services. Dates and time for completion of the above shall be mutually agreed upon between the Contracting Officer, Contracting Officer’s Representative, and the Contractor.

- Ensure that all exam data is completely transferred to the medical center prior to securing operations for the workday.

- All patient exams shall be burned to a disc in DICOM format and labeled for archive. The discs will be delivered to a designated VA staff member for storage on site at the VA. The discs shall be the property of the VA. A log will be kept by the contractor of all discs generated. The log will contain the following information: who created the disc, who gave the disc to the VA, which VA staff member received the disc and the dates of the contents.

*Not applicable if contractor provides interpretation viewing system however contractor shall have the capability to utilize disc storage in case VA PACS is not functioning properly.

· All patient exam data is purged from contractor’s computer systems once it is verified that exams are viewable on the PACS.

· All connections from the trailer to VA property are properly disconnected prior to moving or removing the trailer.

An audit of the MRI service shall be accomplished at least annually by the site Radiation Safety Officer. This audit shall be scheduled with the contractor a minimum of two weeks in advance and will take no more than 60 minutes per period.

The Contractor agrees to ensure compliance/acceptance testing of the MRI equipment is performed on at least an annual basis or if major components of the machine are serviced or replaced. The compliance/acceptance tests will be done in accordance with nationally recognized standards (NCRP, AAPM) and meet or exceed TJC requirements.

The Contractor shall be responsible for ensuring the compliance testing of the MRI system is performed by a qualified medical physicist. A qualified medical physicist as defined is an individual who is certified by the American Board of Radiology, American Board of Health Physics, or American Board of Medical Physics in the appropriate disciplines of radiologic physics, and maintain state certification as a Health Physicist in the state of Montana.

The Contractor shall be responsible for maintaining all appropriate records and documentation relevant to compliance and performance of the equipment.

1. TRAINING

The contractor shall be responsible for training the radiologists on the use of the Contractor provided workstations and image analysis software.

The contractor shall be responsible for training assigned technologists on the proper use and operation of the MRI system on site.

1. JOINT COMMISION ACCREDITAION OF HEALTHCARE ORGANIZATIONS (TJC/QUALITY ASSURANCE/VA & OCCUPATIONAL SAFETY HEALTH ADMINISTRATION)

The contractor shall meet or exceed The Joint Commission for Accreditation (TJC) and shall meet or exceed TJC guidelines as they pertain to MRI operations, infection control, patient safety, and shall follow the guidelines of the Department of Veteran’s Affairs (VA) and Occupational Safety Health Administration (OSHA). Quality assurance survey reports that meet or exceed TJC accreditation shall be provided to the Contracting Officer’s Representative (COR) consistent with TJC recommendations.

1. MRI STRUCTURE/EQUIPMENT MAINTENANCE/EMERGENCY REPAIRS

Equipment provided shall always be in good working order to provide high quality test and scans required under this contract. Contractor shall be responsible for the preventive maintenance, emergency, and scheduled repairs, safety, cleaning, and upkeep of all equipment furnished by the Contractor. Preventative maintenance and all repairs on the mobile unit(s) and all associated equipment shall be performed in accordance with the conformance standards and manufacturer’s recommendations. Contractor shall provide annual compliance testing of MRI equipment by a qualified medical physicist. Documentation shall be provided to verify standards meet or exceed TJC guidelines.

In the event of an equipment failure during normal working hours while in the performance of the Contractor’s services, the Contractor shall notify the COR or designee immediately after discovery of equipment failure and shall respond within 24 hours of notification. If maintenance is required to be performed on site after the normal working hours, the Contractor must notify the VA Police that services will be performed on-site. All emergency repairs are the responsibility of the contractor.

The COR shall determine if appointments previously scheduled should be cancelled and rescheduled as a result of the equipment failure. If the equipment fails and cannot be repaired, the Contractor must provide an alternate unit which will be available on the next scheduled day and meets all the requirements this contract.

Contractor agrees to reimburse the VA for costs over and above the contracted cost associated with obtaining exams though other sources which are necessary for cancelled or postponed appointments as a result of equipment failure.

1. SCHEDULING OF PATIENTS/SERVICES AND NORMAL HOURS OF OPERATION

Contractor personnel shall be available on site to perform exams on patients for up to nine (9) hours per day each weekday identified by the schedule, excluding Federal holidays. Exams will start no later than (NLT) 8:00 a.m. and the last exam will be completed on or before 5:00 p.m. Trailer delivery, setup, and daily quality control procedures shall not delay the start of examinations. Hours of operation less than nine hours must be approved in advance by the COR. Within the reduced work period, all scheduled examinations must be accomplished as well as any new orders brought to the attention of the contractor’s staff by 5:00 pm on the date prior to the visit.

(a) National Holidays: The eleven (11) holidays observed by the Federal Government, are New Year's Day, Dr. Martin Luther King Jr.'s Birthday, Presidents Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving, and Christmas or any other day specifically declared by the President of the United States to be a national holiday.

(b) Off-Duty Hours: Days and hours other than stated above.

Scheduling conflicts, which cannot be resolved, will be decided by the Contracting Officer. The VA shall consider alternative schedules if advantageous to the Government.

1. CANCELLATIONS/NO CHARGE SERVICES

The Contractor shall not charge the VA for exams when:

Exam is cancelled at least 24 hours in advance of any scheduled procedure. If the above should occur, the Contractor shall not include the cost of the cancelled scan(s) in its monthly invoice.

The quality of the exam is unacceptable as determined by the VA radiologist interpreting the exam. Factors include but are not limited to poor positioning, inadequate contrast media, or motion during scan acquisitions. Contractor will be notified by the COR if the above should occur and monthly billing shall be adjusted accordingly.

On the day of the exam, new contraindications for the exam are discovered resulting in cancellation of the exam for the patient’s safety.

On the day of the exam, the patient is found to be claustrophobic or is otherwise unable to complete the examination.

There is insufficient contractor staff to perform procedures. Exams cancelled or postponed due to failure of services provided by the contractor shall be rescheduled and performed by the contractor at the original imaging site within seven (7) days of the initial appointment during the normal operating hours of the clinic services. If it is not possible to reschedule the patient within seven (7) days and the VA site must make alternate arrangement to have the patient sent to another facility for the tests, the Contractor shall bear the costs associated with such re-procurement exceeding the contracted exam charge. The VA shall provide the Contractor with an itemized list of costs as a result of any service failure and cost will be deducted from the Contractor’s invoice for the period involved.

1. CONTRACTOR STAFF QUALIFICATIONS/RESPONSIBILITIES

· All personnel shall be certified in basic life support (BLS) CPR.

· MRI technologists must be licensed/certified in the state of Montana and be certified by the American Registry of Radiologic Technologists (ARRT) in order to provide all services being requested.

· The Contractor is required to develop and maintain the following documents for each Contractor employee:

· Credentials and qualifications for the job.

· Current competence assessment checklist (an assessment of knowledge, skills, abilities and behaviors required to perform a job correctly and skillfully; including knowledge and skills required to provide care for certain patient populations, as appropriate.

· Current performance evaluation supporting ability of the Contractor employee to successfully perform the required services.

· Relevant continuing education for the last two (2) years.

· The Contractor shall provide current copies of the above records to the COR at the time of award, on the anniversary date of contract award to the VA, and upon request.

· Contractor personnel will abide by all policies of the site of service to include but not limited to, smoking, radiation, and patient safety policies.

· Personnel assigned by the Contractor to perform the services covered by this contract shall be proficient in written and spoken English (38 US Code § 7402). Contractor’s technologists shall be required to type patient information into the MRI computer ensuring that all images are identified with the correct patient information to include full name, social security number, date/accession number, and modality type.

· Contractor’s personnel shall be computer literate in the type of software and/or hardware associate with their duties. Assigned technologists and health aid technicians will be required to utilize VA computer programs which include but are not limited to CPRS, VistA, Outlook, Teams messaging, etc.

· The MRI technologist shall be trained and qualified to screen patients using a facility questionnaire for potential contraindications to MRI imaging, based on facility imaging procedure/protocols.

· Technologist shall maintain a log of all VA patients receiving MRI scans and provide a copy of the same to the onsite COR. Such logs shall be available for inspection by duly authorized representatives of the facility upon reasonable notice to the mobile unit’s personnel. Inspection shall be during normal working hours of the mobile unit while at the facility.

· Technologist shall ensure that, when applicable, patient informed consent (according to applicable VHA policies/procedures) is obtained and presented prior to performing examinations.

· Technologist shall be responsible to screen patients prior to performing exams/procedures by properly verify the patient’s identification using full name and date of birth. Technologists will screen patients for pregnancy, breast-feeding status, and confirm the procedure to be performed prior to commencement of any services. Disqualification of a patient from the exam must be documented and provided to designated facility staff before the patient leaves the MRI unit. Any examination that is unsafe to perform shall be immediately reported the facility staff member and to the patient’s physician before the patient leaves the facility.

· Any side effects that may develop from injection of contrast media or from patient preparation shall be reported to the onsite radiologist or designated practitioner as quickly as possible considering the clinical situation while the patient is in the trailer.

· The MRI technologist shall be responsible for the initial assessment and identification of medical emergencies and initiating the emergency response procedure for patients in their care. The training for this shall be a part of initial facility orientation, annual radiation/MRI patient safety surveys, and age specific competencies. Patients requiring transfer to the Emergency Department for assessment shall be accompanied by the contractor technologist.

· MRI technologist shall ensure that all MRI exams are acquired and processed per procedures and protocols provided by the facility radiologist. Raw and processed data shall remain the property of the government.

· MRI technologist shall present (electronically transmit and notify) each completed MRI examination to the designated facility radiologist to review for diagnostic quality before the patient is discharged back to the medical center. VA radiologists shall perform interpretations of the examination(s). Unsatisfactory or non-diagnostic MRI scans shall be re-performed at the discretion of designated radiologist at no additional cost to the VA.

· Contractor shall meet the safety requirements of posting strong magnetic field hazard signs around the mobile unit. Contractor will provide appropriate physical barriers to maintain safe distances from the MRI scan trailer. Contractor will ensure all cables, hoses, and pipes are properly secured under protective hard covers/tunnel plates to prevent trip hazards and damage to equipment.

· Neither the Contractor nor the contract personnel shall in any way undertake the practice of medicine, render medical opinions, nor offer services other than those required to support the well-being of the patient or to provide ancillary and technical services required for the operation of the unit.

1. ADDITIONAL/REPLACEMENT PERSONNEL

Additional personnel required due to an increase in patient workload or replacement personnel due to employee turnover shall meet all requirements stated herein. The contractor shall notify the COR immediately of any changes in personnel. The contractor shall submit all certifications, licenses and training document to the Contracting Officer for review and approval to include completion of background check prior to contract employee reporting for work.

1. GOVERNMENT RESPONSIBILITIES

The Fort Harrison VA medical center shall provide all patient services, with exception of the services provided by the Contractor’s MRI technologist to include the following:

· Retain full medical responsibility for its patients. Contractor shall be responsible for patient upon pickup at the designated waiting area, while in the mobile imaging unit and during the entire scanning procedure until patient is returned to the designated waiting area.

· Approval and scheduling of patients for MRI exams shall be provided by the Montana VA HCS facility. When necessary, the facility shall fax a patient list of exams and exam times to the Contractor. The Contractor shall follow up with phone verification of the patient list.

· Pre-test screening will be provided by the Montana VA Healthcare facility and or the contractor. These patients shall be made available to the Contractor at the specified appointment time.

· The Montana VA Healthcare facility shall be responsible for transporting patients to and from the facility furnished waiting area. Contractor shall be responsible to pick up and transport the patient to the Contractor furnished mobile trailer/building. Upon completion of services, the Contractor shall return patient to the designated waiting area within the Medical Center.

· The Montana VA medical center shall be responsible for scheduling and handling patient issues that would prevent the patient from being available for the scheduled exam. This will be communicated by the facility to the Contractor.

· The Contractor provided MRI technologists shall observe orally sedated patients in the Contractor’s trailer. The Montana VA Healthcare facility shall identify these patients and provide/administer any oral sedation that patients may require prior to the scans provided by the Contractor.

· Conscious sedation procedures will not be performed without proper MRI conditional equipment to monitor the patient. Montana VA Healthcare facility is responsible for ensuring qualified providers are present during the exam. Assigned providers will be properly screened for the MRI environment and must complete all assigned MRI training prior to entering the MRI environment.

· The VA facility shall ensure each patient arriving for MRI scans has a written physician order to receive services and such other forms or information as required.

· All medical supplies, facilities, personnel, and physicians to provide patients with emergency medical care including oxygen, aspirator, and defibrillator when deemed necessary.

1. DOCUMENTATION/REPORTS

The Contractor shall provide to the COR equipment and maintenance reports as requested. The Contractor shall also provide system pre-check and associated documentation at the time the unit is set up at the site where services are to be performed.

The Contractor shall permit onsite inspection by personnel selected by the VA without prior notice to verify the Contractor’s equipment is operated in accordance with appropriate safety guidelines and/or regulations.

Additional reports/documentation shall be provided as requested/required by the CO prior to commencement of services of MRI technologist and equipment service records. The VA may require specialized documentation to satisfy the requirements of local state and federal government agencies, and independent consultants such as the Joint Commission, as well as for “services rendered” verification for payment of monthly statement. At a minimum, the following information shall be provided to the Contracting Officer:

· Certificate of Insurance not limited to but includes Professional Liability, Worker’s Compensation, liability, and property insurance of Contractor’s furnished equipment which shall be submitted to the Contracting Officer within ten (10) calendar days of receipt of notification of award.

· The government is not responsible nor liable for any damage or vandalism which may occur to the Contractor’s equipment while on federal property.

· Copy of appropriate business license – submitted with signed proposal.

· Contractor’s employees’ certifications/registrations, competency records and training certificates to be submitted with signed proposal as defined herein.

· Technologists health examination records of annual TB testing and recent chest radiographs if the contract employee has a medical history for positive TB test. Copies of records shall be submitted to the Contracting Officer prior to commencement of services.

· A copy of the MRI trailer requirements for docking pad and infrastructure will be submitted with signed proposal.

· Documentation of a proposed schedule included in the submission along with maximum throughput of proposed system(s) will be submitted with signed proposal.

1. INSPECTION/ACCEPTANCE

Inspection and acceptance of all work performance, reports, and other deliverables under this contract shall be performed onsite.

Deliverables shall be inspected for content, completeness, accuracy, and conformance to contract requirements by the COR. Inspection shall include validation of information or software using automated tools and/or testing of the deliverables. The scope and nature of this testing shall be negotiated prior to providing services and shall be sufficiently comprehensive to ensure the completeness, quality and adequacy of all deliverables.

Reports, documents and narrative type deliverables shall only be accepted when all discrepancies, errors, or other deficiencies identified in writing by the government have been corrected.

Maintenance logs shall be available upon request for inspection.

Contractor shall be responsible for providing quality reviews to ensure adequate diagnostic image quality. The government reserves the right to require corrective action if image quality or other service problems are brought to the attention of the Contractor.

Nonconforming products or services shall be rejected. Unless otherwise agreed by the parties, deficiencies will be corrected within seven (7) days of the rejection notice. If the deficiencies cannot be corrected within seven (7) days, the Contractor will immediately notify the COR and the Contracting Officer of the reason for the delay and provide a proposed corrective action plan within seven (7) working days.

1. PRIVACY AWARENESS TRAINING

Contractor personnel assigned work under the contract are required to receive annual training on patient privacy as established by HIPAA statutes. Training must meet VHA and Department of Health and Human Services Standards for Privacy of Individually identifiable health information. Contractor shall provide documented proof to the contracting officer that all employees assigned work and/or having access to Protected Health Information (PHI) have received annual training. Proof of training is to be forwarded to the Contracting Officer.

The contractor shall provide to the Contracting Officer and/or the COR a copy of the training certificates for each applicable employee. Mandatory courses that must be completed are:

TMS course # 10176 titled “VA Privacy and Information Security Awareness and Rules of Behavior” TMS course # 10203 titled “Privacy and HIPAA Focused Training”

Note: Completion of TMS course # 10176 titled “VA Privacy and Security Awareness and Rules of Behavior” satisfies the requirement for certifying and signing the Contractor Rules of Behavior for each applicable employee. TMS can be accessed at https://www.tms.va.gov.

Rules of Behavior for Automated Information Systems: Contractor personnel having access to VA information systems are required to read and sign a Rules of Behavior statement which outlines rules of behavior related to VA Automated Information Systems. Failure to complete the mandatory training (including completion of TMS course #10176 titled “VA Privacy and Security Awareness and Rules of Behavior” and completion of TMS course #10203 titled “Privacy and HIPAA Focused Training” within the timeframe required, is grounds for suspension or termination of all physical or electronic access privileges and removal from work on the contract until such time as the training and documents are complete.

1. REMOVAL OF CONTRACTOR EQUIPMENT

At the termination of the contract, the VA site will retain custody of all hard drives containing patient information covered under HIPPA regulations.

VA information retained by the MRI scanning systems and other contractor equipment shall be returned to the VA at the end of the contract and when no longer required for regulatory purposes. The contractor shall be responsible for and verifying all VA patient and other information is completely deleted from all equipment at the end of the contract.

The contractor will remove the trailer and mobile imaging systems from VA property within seven (7) business days after the end of the final Period of Performance.

Inclement/harsh weather conditions will be taken into consideration during installation and/or removal of contractor provided equipment. Requests for additional time may be submitted in writing to the Contracting Officer. The government reserves the right to approve/disapprove requests for additional time.

STANDARD BUSINESS HOURS: Standard business hours at this location occur between 8:00 a.m. to 4:30 p.m., Monday through Friday, excluding Federal holidays.

FEDERAL HOLIDAYS: Federal holidays are any calendar days designated by statute or executive order as federal holidays, and as presented on the OPM website for the respective year in which services are to be performed. Refer to U.S. Office of Personnel Management, at OPM.gov. Federal holidays consist of New Year's Day, Martin Luther King Jr's birthday, President's Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving and Christmas. Holidays that fall on Saturday are observed on the preceding Friday. Holidays that fall on Sunday are observed on the following Monday. In addition to the days designated as holidays, the Government observes the following days:

· Any other day designated by Federal Statute

· Any other day designated by Executive Order

· Any other day designated by the President of the United States to be a Federal holiday.

Local VA Representatives Upon contract commencement, the Contracting Officer will notify the Contractor of a local VA staff to act as a point of contact assigned to this contract. Contractor shall only respond to requests for service from the VA locally assigned POC, as written in this contract, or the CO. If service is requested from any source, other than the CO, the Contractor is to advise the individual of this requirement and refuse to respond. Any billing resulting from unauthorized service will not be paid by the government. The Government reserves the right to inspect and test services in accordance with this PWS and the Contract.

Authority to Make Changes The Contracting Officer is the only person authorized to approve changes in any of the requirements of this contract. In the event the Contractor affects any changes at the direction of any person other than the Contracting Officer, the changes will be considered to have been made without authority and no adjustment will be made in the contract price or schedule to cover any increase in costs incurred as a result thereof. The Contracting Officer shall be the only individual authorized to accept nonconforming work, waive any requirement of the contract, and/or modify any term or condition of the contract. The Contracting Officer is the only individual who can legally obligate Government funds. No costs chargeable to the proposed contract can be incurred before receipt of a fully executed contract or specific authorization from the Contracting Officer.

Safety and Compliance The Contractor must perform services in accordance with:

a) local, state and federal Occupational Safety and Health guidelines and legislation, which includes Occupational Safety and Health Administration (OSHA).

b) local, state and federal guidelines and legislation, as well as VA Medical Center Directives and guidelines, relating to chemicals and usage of chemicals.

c) local, state and federal Fire and Safety legislation and guidelines, to include VA Medical Center directives and legislation on Fire and Safety, as well as the latest published edition of NFPA-99 (Health Care Facilities Code); and

d) 29 CFR 1910.132, Personal Protective Equipment.

The contractor is also responsible for immediately notifying the local VA Local POC at the first instance a safety issue or risk is identified during the Service.

Remedy or Rework

Rework or Remedy is defined as performing the Service again until the Purpose of this PWS is achieved in full. This involves less than Satisfactory Service by the Contractor and as noted by the local VA POC.

Rework or Remedy must occur within 3 business days of the notice of the rework or remedy requirement from the local VA POC and at no additional cost to the Government.

Inspection and Acceptance of Services: The Government reserves the right to inspect in accordance with this PWS and the Contract. The only individual authorized to officially accept services is the local VA POC. While inspection of services may be delegated by the local VA POC and a shared responsibility with departmental management staff, the local VA POC is ultimately the only authorized individual to approve and accept services on behalf of the VA.

Medical Center Policies

Each VA Medical Center has policies that are updated from time to time. The local VA POC can provide more detailed information to the contractor of these upon commencement of the contract and throughout the term of the contract, as needed, especially policies and constraints regarding parking, possession of weapons, cell phone use and photography as well as smoking on VA property. Violations of such policies may result in individual fines or citation answerable in the United States (Federal) District Court.

Contractor Point of Contact (POC) The Contractor shall specify an individual who shall serve as a single point of contact for all contract issues (POC). Contractor must provide the COR and Contracting Office with the POC contact details, to include business phone number or cell phone number and email, as a minimum:

a) Within 5 business days of contract award,

b) Within 5 business days after renewal or extension of services in accordance with, and if permitted by applicable FAR clause, and

c) Within 5 business days prior to a change in the POC by the Contractor.

The POC must be easily accessible by phone and return COR calls within 48 hours of a voice message left by the COR.

Contracting Officer’s Representative (COR) Upon contract commencement, the Contracting Officer will notify the Contractor in writing as to the COR assigned to this contract, and upon reassignment of a new COR, as applicable. Contractor shall only respond to requests for service from the COR or the CO. If service is requested from any source, other than the COR or the CO, the Contractor is to advise the individual of this requirement and refuse to respond. Any billing resulting from unauthorized service will not be paid by the government. The COR will evaluate the contractor’s performance through review of the Contractor’s Quality Control Procedures in accordance with this contract and PWS.

Authority of the COR The Contracting Officer is the only person authorized to approve changes in any of the requirements of this contract. In the event the Contractor affects any changes at the direction of any person other than the Contracting Officer, the changes will be considered to have been made without authority and no adjustment will be made in the contract price or schedule to cover any increase in costs incurred as a result thereof. The Contracting Officer shall be the only individual authorized to accept nonconforming work, waive any requirement of the contract, and/or modify any term or condition of the contract. The Contracting Officer is the only individual who can legally obligate Government funds. No costs chargeable to the proposed contract can be incurred before receipt of a fully executed contract or specific authorization from the Contracting Officer. Any invoicing or charges resulting from unauthorized service will not be paid by the government.

Government Alternate Points of Contact (POC) – Emergencies Only The COR will identify Alternate Points of Contact (POC) to be used only for instances of emergencies when the COR is not easily contactable. These will be individuals in supervisory or managerial roles within the Biomed department. The contractor will be provided this information within 5 days after contract award and within 48 hours of a change to this information. An Alternate POC does not replace the COR nor do they replace the Contracting Officer during the performance and administration of this contract, nor does it relinquish or diminish the Contractor’s requirements in relation to the performance of this Contract.

LIABILITIES AND INSURANCES

Protection from Damage Contractor shall provide all labor, materials, and equipment necessary for protection of VAMC personnel, furnishings, equipment and buildings from damage, and shall replace or repair any damage due to…