410lb Dryer Salient Characteristics_updated.pdf
PDF 202 KB Posted
- Attached to
- Industrial Dryer Equipment - ADG 410
- Solicitation number
- FA500026Q0051
About this file
This is a Product Specifications memorandum from the Department of the Air Force, 673d Air Base Wing at Joint Base Elmendorf-Richardson, Alaska, dated 30 June 2026, establishing technical requirements for the procurement of a replacement 410-pound capacity gas dryer. The memorandum is directed to the Contracting Office (673d CONS/LGCC) from the Facility Services Division (673 FSS/FSV) and serves as the baseline specification document for acquiring equipment functionally equivalent or superior to the existing American Dryer Corporation Model ADG410DD.
The required dryer must meet specific electrical specifications including 208-220V three-phase power with 100-amp circuit breaker capability and 50-60 Hz frequency. Performance requirements include 1,400,000 BTU/hr heat input, maximum load capacity of 400-475 pounds, tumbler volume of at least 140 cubic feet, 9,200 CFM airflow, and a minimum of six programmable cycles. Physical installation requirements specify rear exhaust dimensions of 24-28 inches, equipment that must fit within the existing space of 8'6"W x 6'6"D x 10'H, and dual tilt capabilities (forward and backward). The contractor is responsible for complete installation including all utility connections to existing gas, air, and electrical systems; removal and relocation of the old unit (requiring a forklift capable of lifting 5,000-15,000 pounds); and any necessary modifications to utilities using qualified technicians. The dryer must connect to the facility's S.A.F.E. System water connection with 1-inch female pipe thread at 40-100 PSI. Technical acceptability is limited to Susan Meyer, GS-09, Assistant Laundry Manager, or designated representatives; points of contact include Brenda Brown at brenda.brown.9@us.af.mil, (907)854-2429, and Susan Meyer at susan.meyer.1@us.af.mil, (907)384-1903.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Clarification Questions and Answers.pdf | ||
| Solicitation - FA500026Q0051 (1).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
673D AIR BASE WING
JOINT BASE ELMENDORF-RICHARDSON ALASKA
30 June 2026
MEMORANDUM FOR: 673d CONS/LGCC
FROM: 673 FSS/FSV
SUBJECT: Product Specifications for 410lb Gas Dryer
1. General requirement: 673 FSS/FSVA is replacing one, 410lb Gas Dryer; American Dryer
Corporation, Model number ADG410DD.
2. The specifications listed below describe the baseline for the required equipment. Any new machine must satisfy all these characteristics as a minimum requirement. The purpose is to acquire a replacement that is functionally equivalent or superior to the unit currently in place. The proposed equipment must be fully compatible with, and capable of connecting directly to, the facility’s existing utility connection points (including electrical, gas, water, air, and ventilation exhaust) without requiring government-funded modifications to the building's infrastructure.
Electrical Specifications:
• Voltage: 208 to 220V
• Circuit Breaker: 100 AMPs
• Hertz: 50-60 Hz
• Wires: 3
• Phase: 3
Performance and Capacity:
• Heat Input: 1,400,000 btu/hr
• Max Load: 400 - 475 lbs
• Tumbler Volume: At least 140 cu ft
• Airflow: 9,200 cfrn
• Programmable Cycles: Minimum of 6
Physical and Installation Requirements:
• Exhaust: Rear exhaust, 24"-28"
• Dimensions: Must fit within the space of the current machine (8’6”w x 6’6”d x 10’h).
• Installation: The contractor is responsible for installation, including any necessary modifications to existing utilities.
• Removal of Old Unit: Requires a forklift capable of lifting 5,000 – 15,000 lbs to remove the old machine.
• S.A.F.E. System Water Connection: 1" F.P.T. The dryer must be provided with water at a pressure of 40 PSI minimum and 100 PSI maximum.
• Double Tilt: The dryer must have both forward and backward tilt capabilities.
• Complete Installation: The service includes the full installation of the new dryer.
b. Utility Connections and Modifications: The contractor must connect the new unit to the existing utilities (gas, air, electrical). If any modifications are needed to make the connections work, the contractor is responsible for providing all necessary materials and labor from qualified technicians.
c. Relocation of Existing Equipment: The contractor is required to move the old dryer to a specified staging area within the facility.
3. POC’s: Brenda Brown; brenda.brown.9@us.af.mil-(907)854-2429, Susan Meyer;
susan.meyer.1@us.af.mil-(907)384-1903.
4. Technical acceptability may only be provided by the undersigned or designated representative.
Susan Meyer, GS-09 Assistant Laundry Manager mailto:brenda.brown.9@us.af.mil mailto:susan.meyer.1@us.af.mil-(907)384-1903
| 2026-06-30T12:08:23-0800 | |
| MEYER.SUSAN.ANNE.1138391228 |