4-ECLC Life Safety-Plan.pdf

PDF 1 MB Posted

Attached to
Early Childhood Learning Center Operator
Solicitation number
25-0087-5
Issued by
Chatham County, Georgia

About this file

This document is a Life Safety Composite First Floor Plan for the Early Child Learning Center project in Savannah, Georgia, prepared by Cogdell Mendrala Architects for Chatham County and East Savannah United. The project involves the construction of a 21,580 square foot early learning facility located at 901 East Perry Lane, designed in compliance with multiple building codes including the 2018 International Building Code, International Fire Code, and various other state and national standards. The facility includes multiple classroom spaces for infants, toddlers, and preschoolers, administrative offices, support areas like a kitchen, storage rooms, playgrounds, and necessary utility spaces.

The design incorporates comprehensive life safety features, including detailed wall ratings, fire-rated door assemblies, exit separations, and egress calculations. The floor plan meticulously outlines room dimensions, occupancy capacities, and specific use designations for each space, with net square footage provided for areas ranging from classrooms (787-1011 sq ft) to support spaces like restrooms, corridors, and mechanical rooms. The document was prepared in August 2024, with recent revisions on 10/07/24 and 10/15/24, and involves multiple project consultants including Dulohery Weeks (M.E.P. Engineers), Saussy Engineering (Structural Engineers), Moffatt & Nichol (Civil Engineers), and Mandel Design, LLC (Landscape Architect).

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0' - 3"

COMMON PATH

0' - 3"

DEAD END

0' - 3"

0' - 3"

MAX. DIAGONAL

0' - 3"

EXIT SEPARATION

W/D

299' - 0"

MAX. DIAGONAL

41' - 5"

64' - 1"

1"

F E

C

FEC

F E

C

FEC

FEC

F E

C

F E

-K

206' - 9"

EXIT SEPARATION

9' - 0"

COMMON PATH

NUMBER IN DIAMOND INDICATES NUMBER OF OCCUPANTS IN

ANY SPACE CALCULATED FROM LOAD FACTORS (LSC/IBC)

SPACE CONSIDERED AS BEING UNOCCUPIED AND NOT

INCLUDED WITH IN CALCULATIONS

SPACE CONSIDERED AS BEING OCCUPIED AND INCLUDED IN

CALCULATIONS

NUMBER IN OCTAGON INDICATES NUMBER OF ACTUAL

OCCUPANTS IN SPACE

NUMBER IN CIRCLE INDICATES EGRESS CAPACITY OF OPENING

20-MINUTE FIRE-RATED DOOR ASSEMBLY

45-MINUTE FIRE-RATED DOOR ASSEMBLY

1-HOUR FIRE-RATED DOOR ASSEMBLY

1-1/2 HOUR FIRE-RATED DOOR ASSEMBLY

EXIT/AREA OF REFUGE LIGHT

FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER BRACKET

FEC

C

B1

B2

FEB

X

X

COMMON PATH OF TRAVEL

(XX FT. MAX)

DEAD END CORRIDOR

(XX FT. MAX)

TRAVEL DISTANCE

MAX DIAGONAL DISTANCE

EXIT SEPARATION

PROPERTY ADDRESS: EARLY CHILD LEARNING CENTER

901 EAST PERRY LANE

SAVANNAH, GA

APPLICABLE BUILDING CODES WITH GEORGIA AMENDMENTS:

(LIST IS NOT INCLUSIVE)

I. International Building Code, 2018 Edition, with Georgia Amendments (2020), (2022), (2024)

II. International Fire Code, 2018 Edition, with Georgia Ammendments (2020), (2024) III. International Plumbing Code, 2018 Edition, with Georgia Amendments (2020), (2022), (2023), (2024) IV. International Mechanical Code, 2018 Edition, with Georgia Amendments (2020), (2024) V. International Fuel Gas Code, 2018 Edition, with Georgia Amendments (2020), (2022) VI. National Electrical Code, 2020 Edition with Georgia Amendments (2021) VII. International Energy Conservation Code, 2015 Edition, with Georgia Supplements and Ammendments (2020), (2022), (2023) VIII. Life Safety Code, NFPA 101, 2018 Edition with Georgia Amendments (2020) IX. NFPA 70 National Electrical Code, 2020 Edition (No Georgia Amendments) X. NFPA 72 National Fire Alarm & Signaling Code 2019 Edition, with Georgia

Amendments (2020) XI. NFPA 13 Standard for the Installation of Sprinkler Systems 2019 Edition, with

Georgia Amendments (2020) XII. DOJ 2010 ADA Standards for Accessible Design XIII. Georgia State Board of Education Standards and Guidelines

GROSS ENCLOSED PROJECT AREA: 21,580 SF

REFER TO BUILDING ELEVATIONS AND SECTIONS FOR EXTERIOR

WALL TYPES AND MATERIALS.

THIS SYMBOL DESIGNATES WALL TYPES. REFER TO SHEET A0.01 &

A0.02 FOR MORE SPECIFIC INFORMATION REGARDING WALL TYPES.

UL-RATED ONE-HOUR SEPARATION

ASSEMBLY OR FIRE PARTITION, UNLESS

OTHERWISE NOTED

NOTE: ALL ARE SHOWN IN COLOR ON ALL

LIFE SAFETY DRAWINGS. LIFE SAFETY DRAWINGS ARE NOT VALID UNLESS

DEPICTED IN COLOR.

WALL AND PARTITION RATINGS

UL-RATED THREE-HOUR SEPARATION

ASSEMBLY OR FIRE PARTITION, UNLESS

OTHERWISE NOTED

UL-RATED FOUR-HOUR SEPARATION

ASSEMBLY OR FIRE PARTITION, UNLESS

OTHERWISE NOTED

NON-RATED SMOKE-RESISTIVE

SEPARATION ASSEMBLY OR PARTITION,

UNLESS OTHERWISE NOTED

UL-RATED ONE-HOUR CEILING

ASSEMBLY

UL-RATED TWO-HOUR SEPARATION

ASSEMBLY OR FIRE PARTITION, UNLESS

OTHERWISE NOTED

X.X.X

X X

80 SF NET

STORAGE

270 SF NET

CLINIC

175 SF NET

PLANNING /

WORKROOM

172 SF NET

BREAKROOM

479 SF NET

KITCHEN

96 SF NET

WALK IN

FREEZER

156 SF NET

FAMILY

SERVICES

OFFICE II

144 SF NET

FAMILY

SERVICES

OFFICE I

203 SF NET

SUPERVISOR

176 SF NET

ASSISTANT

SUPERVISOR

188 SF NET

LOBBY

127 SF NET

RECEPTIONIST

117 SF NET

VESTIBULE

68 SF NET

ELECTRICAL

179 SF NET

STORAGE

51 SF NET

LAUNDRY

69 SF NET

MDF

70 SF NET

STORAGE

900 SF NET

MULTIPURPOSE

1986 SF NET

LIBRARY

787 SF NET

PRE-SCHOOL

CLASSROOM840 SF NET

PRE-SCHOOL

CLASSROOM

792 SF NET

PRE-SCHOOL

CLASSROOM

817 SF NET

PRE-SCHOOL

CLASSROOM

841 SF NET

PRE-SCHOOL

CLASSROOM

787 SF NET

PRE-SCHOOL

CLASSROOM

1011 SF NET

INFANT/TODDLER

CLASSROOM

1008 SF NET

INFANT/TODDLER

CLASSROOM

1009 SF NET

INFANT/TODDLER

CLASSROOM

1005 SF NET

INFANT/TODDLER

CLASSROOM

973 SF NET

INFANT/TODDLER

CLASSROOM

59 SF NET

BED

453 SF NET

CORRIDOR

527 SF NET

CORRIDOR

1363 SF NET

CORRIDOR

423 SF NET

CORRIDOR

1073 SF NET

CORRIDOR

7142 SF NET

PRESCHOOL

PLAYGROUND

1997 SF NET

INFANT

PLAYGROUND

3310 SF NET

TODDLER PLAYGROUND

63 SF NET

RESTROOM

63 SF NET

RESTROOM

41 SF NET

JAN.

59 SF NET

RESTROOM

59 SF NET

RESTROOM

78 SF NET

RESTROOM

78 SF NET

RESTROOM

87 SF NET

RESTROOM

33 SF NET

JAN.

84 SF NET

RESTROOM

79 SF NET

RESTROOM

79 SF NET

RESTROOM

172 SF NET

PANTRY

DUMPSTER

44' - 9"

NORTH

517 EAST CONGRESS STREET

SAVANNAH, GEORGIA 31401

tel 912.234.6318 fax 912.236.8414 cogdellmendrala.com

PROJECT CONSULTANTS:

SEAL:

SHEET TITLE:

PROJECT NO:

DRAWN BY:

DATE:

SCALE:

SHEET:

KEY PLAN:

COGDELL & MENDRALA ARCHITECTS, PC

M.E.P. ENGINEERS:

DULOHERY WEEKS, INC.

10 Chatham Center S Dr, Suite 200, Savannah, GA 31405

Cogdell Mendrala Architect s

STRUCTURAL ENGINEERS:

SAUSSY ENGINEERING

400 Johnny Mercer Blvd, Suite E, Savannah, GA 31410

CIVIL ENGINEERS:

MOFFATT & NICHOL

2 E Bryan St, Suite 501, Savannah, GA 31401

LANDSCAPE ARCHITECT:

MANDEL DESIGN, LLC

7 Baker Drive Savannah, GA 31401

As indicated1 /1

/2

:0 :3

P

M C

U s e rs

\j ja m e s \D o c u m e n ts \2

C

C -E

C L

C C

E N

T R

A L

R

V T

J J a m e s V

Y

.r v t

LS1.01

LIFE SAFETY -

COMPOSITE

FIRST FLOOR

PLAN

KMH

AUGUST 2024

C O

N S T R U

C T

IO

N D

O C U

M E N

T S

E A

R L

Y C

H

IL

D L

E A

R N

IN

G

C E

N T

E R

E

A S

T P

E R

R Y

L A

N E

S A

V A

N N

A H

G

A

C H

A T

H A

M C

O U

N T

Y

E A

S T

S A

V A

N N

A H

U N

IT

E

D

LIFE SAFETY LEGEND

LIFE SAFETY DISTANCES

GENERAL INFORMATION

LIFE SAFETY WALL RATINGS

GENERAL LIFE SAFETY NOTES

1 REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL LIFE SAFETY INFORMATION.

2 REFER TO FLOOR PLANS, BUILDING ELEVATIONS, AND SECTIONS FOR EXTERIOR WALL TYPES AND

MATERIALS.

3 ALL RATED WALLS OR SMOKE BARRIERS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH STENCILING ABOVE DECORATIVE CEILING OR CONCEALED SPACES WITH LETTERS A MINIMUM OF 3" HIGH ON A CONTRASTING BACKGROUND SPACED A MAXIMUM OF 12'-0" O.C. WITH A MINIMUM OF ONE PER WALL OR BARRIER IN ACCORDANCE WITH MODIFICATIONS OF THE 2012 INTERNATIONAL

FIRE CODE, 120-3-3-04, CHAPTER 7 OF THE RULES AND REGULATIONS OF THE FIRE SAFETY

COMMISSIONER. THE HOURLY RATING SHALL BE INCLUDED ON ALL RATED BARRIERS OR WALLS.

WORDING SHALL BE AS FOLLOWS AS APPLICABLE: " '--' HOUR FIRE (AND SMOKE BARRIER) PROTECT

ALL OPENINGS."

4 ALL RATED AND RESISTIVE PARTITIONS/BARRIERS SHALL BE INSPECTED BY CONTRACTOR FOR

CONSTRUCTION COMPLIANCE. ANY VOIDS OR NONCOMPLIANT ITEMS SHALL BE CORRECTED TO

COMPLY WITH INDICTATED CLASSIFICATION.

5 ALL WALL AND PARTITION RATINGS ARE SHOWN IN COLOR ON ALL LIFE SAFETY DRAWINGS. LIFE

SAFETY DRAWINGS ARE NOT VALID UNLESS DEPICTED IN COLOR.

3/32" = 1'-0"LS1.01

LIFE SAFETY1

REVISION SCHEDULE

DATE DESCRIPTION

10/07/24 ADD NO. 3

10/15/24 ASI NO. 1

File details come from the government source that posted it. Updated .