4-!-DA27005-27308050 DFCM Addendum 1.pdf
PDF 4 MB Posted
- Solicitation number
- DA27005
- Issued by
- Utah
About this file
This is Addendum #1 to the bidding documents for a tenant improvement project issued by the State of Utah's Division of Facilities Construction and Management (DFCM) for the World Trade Center 3rd Floor GOED (Governor's Office of Economic Development) space. The addendum, dated July 22, 2026, modifies the original construction documents and becomes part of the contract upon bid submission. Bidders are required to acknowledge receipt of this addendum or face potential disqualification. The project scope involves new tenant improvements on the 3rd floor west side of the World Trade Center, including construction of private offices, a conference room, and open office areas with typical construction and average finish levels. The addendum includes six revised architectural drawings (G001, A101, A121, A131, A600, A700) and one revised mechanical drawing (ME101), addressing clarifications regarding reuse of existing doors and door frames, privacy film applications at glazed assemblies, gypsum board patching and repair requirements, existing finish material reuse, signage plan updates, and mechanical ductwork modifications. The addendum consists of 11 pages total, including an architectural narrative, mechanical changes letter, and full-size drawings prepared by AJC Architects and WHW Engineering.
The construction cost estimate is $150,000.00, with no changes to the solicitation schedule in this addendum. The project is an invitational bid limited to four selected contractors: Gladwell Construction, Northway Construction, RAD Electric, and Strong Solutions. The existing space on the 3rd floor has already been demolished, and the work requires providing walls and finishes as shown on plans, rebuilding the ceiling grid, and preparing the space to receive new systems furniture. Key finish materials include reuse of existing carpet tiles and ceiling tiles wherever possible, with new materials provided only after existing materials have been fully utilized or are unsuitable for reuse. Deferred submittals include building fire sprinkler system modifications, building fire alarm system work, and MEP seismic anchoring and bracing. All bidders must acknowledge receipt of this addendum with their bid submission, and all changes, corrections, deletions, and additions must be included in the bidder's proposal.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3-1-DA27005-27308050 Solicitation.pdf | ||
| 1-2-DA27005-27305050 Hazmat Survey-June 2026.pdf | ||
| 2-3-DA27005-27308050 Approved Plans.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DFCM Addendum Cover Page, 2.26.2026
DFCM Addendum #1 Reference: World Trade Center 3rd Floor GOED Tenant Improvements
CPB - GOED
DFCM Project #27308050 U3P Event #DA27005
Date: July 22, 2026
To: Invited Contractors
From: The Division of Facilities Construction and Management
Note: This Addendum shall be included as part of the Contract Documents. Items in this Addendum apply to all drawings and specification sections whether referenced or not involving the portion of the work added, deleted, modified, or otherwise addressed in the Addendum. Bidders are required to acknowledge receipt of this Addendum when their bid is submitted. Failure to do so may subject the Bidder to disqualification.
Addendum Items
Solicitation Schedule Changes: There are no changes to the Solicitation Schedule in this addendum.
DFCM Addendum Items: N/A
Click to enter text Click to enter text Click to enter text
A/E Addendum Items: A/E Addendum # 1, dated 7.20.2026 Click to enter text
Total Attached Pages: 11
ADDENDUM#1
ajc architects
703 East 1700 South 7/20/2026
Salt Lake City, Utah 84105 GOED – World Trade Center 3rd. Floor Renovation www.ajcarchitects.com Project # 2026-24
Addendum
703 E 1700 S Salt Lake City, Utah 84105 801.466.8818 www.ajcarchitecture.com
Sent By Aid Korkut
Agency Contact
DFCM Levi Waldron lwaldron@utah.gov
Revisions to Project Drawings
I. (6) Architectural: G001, A101, A121, A131, A600, A700
II. (1) Mechanical: ME101
Attachments
This Addendum consists of this cover sheet, Architectural Narrative, Mechanical changes/clarification letter,
(7) full-size drawings, This addendum, issued with written comments, drawings, and/or specifications, is for all persons preparing Bids for the project and, as enumerated herein, shall be included in the Contractor’s Bid; this addendum becomes a part of the
Contract Documents and modifies the original bidding documents. Bidders should acknowledge receipt of this Addendum on the Contractor's Bid Form. Failure to do so may subject the Bidder to disqualification. In case of any conflict between the drawings, specifications, and this addendum, the latest addendum shall govern. All changes, corrections, deletions, and/or additions to the initial bidding documents shall govern. All changes, corrections, deletions, and/or additions to the initial bidding documents shall be included in the Bidder’s proposal. This review does not relieve the contractor or supplier of the responsibility of conforming to the drawings and specifications, nor does it relieve the contractor of the requirements of the specifications for coordination with other trades. All dimensions shall be confirmed and correlated at the job site.
The Contractor shall be responsible for verifying existing conditions and the suitability of “equivalent” products for the specified application.
703 E 1700 S Salt Lake City, Utah 84105 801.466.8818 www.ajcarchitects.com
Addendum #1
Architectural Narrative
703 East 1700 South 7/20/2026
Salt Lake City, Utah 84105 GOED – World Trade Center 3rd Floor Renovation www.ajcarchitects.com Project # 2026-24
Recorded By Aid Korkut
Recipient Contact
DFCM Levi Waldron lwaldron@utah.gov
385.266.5384
Description G001 List of deferred submittals updated
A101 Clarified the reuse of the existing door for the new electrical closet;
Clarified the application of privacy film at glazed assemblies.
Clarified gypsum board patching and repair requirements at existing walls.
A121 Clarified the reuse of existing finish materials.
Clarified finish treatment for the existing hallway wall affected by the new work.
A131 Clarified the reuse of existing ceiling finish materials.
A600 Clarified the reuse of existing door frames and the application of privacy film.
A700 Updated the signage plan in accordance with the Owner's comments.
A L L I
D E
A S
D
E S
IG
N
S A
R R
A N
G E
M E
N T S
A N
D P
L A
N S
I N
D
IC
A T E
D O
R R
E P
R E
S E
N T E
D B
Y T
H
IS
D R
A W
IN
G
A R
E O
W N
E D
B Y
A N
D T
H E
P R
O P
E R
T Y
O F
A
JC
A R
C H
IT
E
C T S
P C
A N
D W
E R
E C
R E
A T E
D E
V O
L V
E D
A
N D
D E
V E
L O
P E
D F
O R
U S
E O
N A
N D
I N
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N O
N E
O F
T H
E I D
E A
S
D E
S
IG
N S
A
R R
A N
G E
M E
N T S
O R
P L A
N S
S H
A L L B
E U
S E
D B
Y O
R D
IS
C
L O
S E
D T
O A
N Y
P E
R S
O N
F
IR
M
O
R C
O R
P O
R A
T
IO
N F
O R
A N
Y P
U R
P O
S E
W H
A T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T O
F A
JC
A
R C
H
IT
E C
T S
P C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
H
V E
P R
E C
E D
E N
C E
O V
E R
S C
A L E
D
IM
E N
S
IO
N S
C
O N
T R
A C
T O
R S
S H
A L L V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
L E
F O
R A
L L D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D
O F
A N
Y V
A R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E S
E
D R
A W
IN
G
S W
A R
N
IN
G R
E P
R O
D U
C T
IO
N H
E R
E O
F I S
A C
R
IM
IN
A
L O
F F
E N
S E
U N
D E
R
U
.S .C
S
E C
U
N A
U T H
O R
IZ
E
D D
IS
C
L O
S U
R E
M A
Y C
O N
S T
IT
U T E
T R
A D
E S
E C
R E
T M
IS
A
P P
R O
P R
IA
T
IO
N I N
V
IO
L A
T
IO
N O
F I .C
.2
-2 -3
-1
E T
S E
Q
A N
D O
T H
E R
L A
W S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
AHJ
A u to d e sk
D o cs
/2
-2
D
FC
M
-G O
E D
R e lo ca ti o n
T I/
G O
E D
R e lo ca ti o n
T I.r vt
/2
/2
:4
:4
P
M
7/8/2026
PERMIT SET
ajc
K. RIGBY
G001
2026-24
60 E SOUTH TEMPLE
SALT LAKE CITY, UT 84150
WORLD TRADE CENTER -
GOED TI
INDEX AND GENERAL
NOTES
GENERAL NOTES:
1 THE GENERAL CONTRACTOR SHALL HEREAFTER BE REFERRED TO AS "GENERAL
CONTRACTOR" OR "GC". THE OWNER MAY HEREAFTER BE REFERRED TO AS "OWNER".
2 THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL WORK REGARDLESS OF THE
LOCATION OF THE INFORMATION IN THE DOCUMENTS. THE GENERAL CONTRACTOR
SHALL UTILIZE THE COMPLETE & ENTIRE CONSTRUCTION DRAWINGS AND WRITTEN
SPECIFICATIONS FOR ALL REQUIRED INFORMATION TO PROVIDE COMPLETE
CONSTRUCTION OF THIS PROJECT AND IS RESPONSIBLE TO COORDINATE ALL DRAWINGS
AND SPECIFICATIONS WITH ALL SUBCONTRACTORS REGARDLESS OF LOCATION IN
CONTRACT DOCUMENTS. ITEMS LISTED IN DRAWINGS MAY NOT BE INCLUDED IN
SPECIFICATIONS. ITEMS LISTED IN SPECIFICATIONS MAY NOT BE INCLUDED IN
DRAWINGS.
3 UNLESS OTHERWISE INDICATED IN THE CONSTRUCTION DOCUMENTS AS BEING NOT IN
CONTRACT (N.I.C.) OR EXISTING, ALL ITEMS, MATERIALS AND INSTALLATION OF SAME
ARE PART OF THE CONTRACT AS DEFINED BY THE ENTIRE CONSTRUCTION DOCUMENTS
AND SPECIFICATIONS. THE GC SHALL PROVIDE AND INSTALL ALL ACCESSORIES,
COMPONENTS AND ASSEMBLIES REQUIRED FOR THE WORK DEPICTED OR SPECIFIED.
4 THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS
PRIOR TO BEGINNING ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND
MATERIALS INCLUDING THOSE FURNISHED BY SUBCONTRACTORS. THE GC SHALL
ACCEPT PREMISES AS FOUND. OWNER WILL MAINTAIN THE EXISTING CONDITION OF THE
SITE AND EXISTING STRUCTURES AT THE TIME OF BIDDING.
5 DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS ARE NOT
INTENDED. THE GENERAL CONTRACTOR IS TO CLARIFY WITH THE ARCHITECT ANY SUCH
DISCREPANCIES DURING BIDDING AND PRIOR TO COMMENCING WORK.
6 DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS: DO NOT SCALE DRAWINGS TO
DETERMINE ANY LOCATIONS. THE ARCHITECT SHALL BE NOTIFIED OF ANY DISCREPANCY
PRIOR TO CONTINUING WITH WORK. CHANGES IN THE WORK TO BE DOCUMENTED IN
WRITING AND APPROVED IN WRITING PRIOR TO BEING STARTED - (IMPLEMENTED)
7 ALL PLAN DIMENSIONS ARE FROM GRIDLINE OR FACE OF STUD OR FACE OF BLOCK
UNLESS OTHERWISE INDICATED. SEE SECTION ON "DIMENSIONING" THIS SHEET.
8 THE CONTRACTOR SHALL REPORT TO THE ARCHITECT ALL CONDITIONS REQUIRING
COORDINATION/ CHANGES WITH THE CONTRACT DOCUMENTS. COORDINATION /
APPROVAL SHALL TAKE PLACE BEFORE THE WORK BEGINS. ALL CHANGES TO THE
CONTRACT COST SHALL BE APPROVED THROUGH A CHANGE ORDER.
9 DETAILED DRAWINGS AND LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER SMALL
SCALE DRAWINGS.
10 THE ARCHITECT WILL REVIEW SHOP DRAWINGS AND SAMPLES FOR CONFORMANCE
WITH DESIGN CONCEPT OF THE PROJECT. THE ARCHITECT'S REVIEW OF A SEPARATE
ITEM SHALL NOT INDICATE APPROVAL OF AN ASSEMBLY IN WHICH THE ITEM FUNCTIONS.
THE ARCHITECT WILL NOT REVIEW SHOP DRAWINGS UNTIL THE GC HAS REVIEWED AND
STAMPED THE SHOP DRAWING/SUBMITTAL. THE GC IS RESPONSIBLE FOR FIELD
VERIFYING ALL DIMENSIONS SHOWN ON THE SHOP DRAWINGS. THE ARCHITECT'S
REVIEW OF THE SHOP DRAWINGS SHALL NOT OVERRIDE THE CONDITIONS DESCRIBED IN
THE CONTRACT DOCUMENTS UNLESS SPECIFICALLY NOTED OTHERWISE BY THE
ARCHITECT. WORK SHALL NOT PROCEED WITHOUT RETURNED REVIEWED SUBMITTALS.
11 FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S STANDARD
DETAILS OR APPROVED SHOP DRAWINGS / DATA SHEETS IN ACCORDANCE WITH THE
PROJECT SPECIFICATIONS.
12 FOR GRADING, TRENCHING ETC., CONTACT THE ARCHITECT FOR INSTRUCTIONS PRIOR
TO THE CONTINUATION OF WORK SHOULD ANY UNUSUAL CONDITIONS BECOME
APPARENT DURING GRADING OR FOUNDATION CONSTRUCTION. EXISTING ELEVATIONS
AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY THE GENERAL CONTRACTOR
BEFORE CONSTRUCTION.
13 ALL WORK, MATERIALS AND METHODS SHALL BE IN CONFORMANCE WITH THE CODES,
ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL AGENCIES HAVING
JURISDICTION AT THE PROJECT LOCATION. THE GENERAL CONTRACTOR MUST COMPLY
WITH THE CONTRACTOR REGISTRATION REQUIREMENTS OF ALL GOVERNING
AUTHORITIES.
14 ALL PROJECT CONSTRUCTION SHALL CONFORM WITH ANSI A-117.1-2009, AND THE
AMERICANS WITH DISABILITIES ACT (ADA).
15 THE GENERAL CONTRACTOR SHALL NOTIFY ALL APPLICABLE LOCAL GOVERNING
AUTHORITIES AND UTILITIES PRIOR TO COVERING UP ANY WORK REQUIRING
INSPECTION.
16 THE GENERAL CONTRACTOR SHALL MAINTAIN ALL REQUIRED EXITS AND FIRE LANES IN
WORKING ORDER.
17 A GENERAL BUILDING PERMIT IS REQUIRED. ALL PERMITS OR CONNECTION FEES SHALL
BE SECURED BY THE GENERAL CONTRACTOR AND REIMBURSED THROUGH THE OWNER.
18 THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL FIRE EXTINGUISHERS WHERE
SHOWN ON PLAN.
19 MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISH SHALL CONFORM TO
THE BUILDING CODE AND LOCAL GOVERNING BUILDING CODES/ORDINANCES. SEE
CODE SUMMARY, SHEET G1002.
20 THE GENERAL CONTRACTOR SHALL PROVIDE AND IS SOLELY RESPONSIBLE AND LIABLE
FOR PUBLIC AND EMPLOYEE PROTECTION AS NECESSARY AND AS REQUIRED BY THE
CODES, INCLUDING EXTERIOR AND INTERIOR PEDESTRIAN TRAFFIC BARRIERS. ALL
WORK SHALL CONFORM TO THE ORDINANCES AND REGULATIONS OF GOVERNMENTAL
AGENCIES HAVING JURISDICTION AT THE PROJECT.
21 THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY BARRICADES FOR DUST AND
NOISE CONTROL, AND ALL REQUIRED ENVIRONMENTAL PROTECTION WHERE WORK
JOINS EXISTING CONDITIONS.
22 ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A
CLEAN (BROOM) CONDITION DAILY.
23 IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO COORDINATE AND
OR CALL BLUE STAKES TO LOCATE ALL EXISTING UTILITIES, WHETHER SHOWN HEREIN
OR NOT, AND WHEN IDENTIFIED TO PROTECT THEM FROM DAMAGE. THE GENERAL
CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF IDENTIFIED
UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE
EXECUTION OF THE WORK.
24 APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY
WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION. THE
GENERAL CONTRACTOR SHALL ALSO MAINTAIN, IN GOOD CONDITION, ONE COMPLETE
SET OF PLANS WITH ALL REVISIONS, ADDENDA AND CHANGE ORDERS, ON THE
PREMISES AT ALL TIMES. THESE ARE TO BE KEPT UNDER THE CARE OF THE JOB
SUPERINTENDENT.
NOTES TO BIDDERS:
SCOPE OF WORK:
DEFERRED SUBMITTALS:
1. BUILDING FIRE SPRINKLER SYSTEM MODIFICATIONS
2. BUILDING FIRE ALARM SYSTEM WORK.
3. MEP SEISMIC ANCHORING AND BRACING.
GENERAL NOTES:
NEW TENANT IMPROVEMENT WITHIN THE EXISTING WORLD TRADE CENTER TOWER ON THE
3TH FLOOR, WEST SIDE OF THE FLOOR. CONSTRUCTION IS A SET OF PRIVATE OFFICES,
CONFERENCE ROOM, AND OPEN OFFICE AREA OF TYPICAL CONSTRUCTION AND AVERAGE
FINISH LEVELS.
EXISTING SPACE WILL NEED TO BE FIELD VERIFIED, MEASURED, AND MODIFIED TO COMPLETE
PROJECT, INCLUDING PLUMBING AND MECHANICAL PENETRATIONS AND NEW FINISHES ON
EXISTING WALLS. CONTRACTOR IS TO ENSURE ENTIRE SPACE IS OF NEW QUALITY AND FINISH
LEVEL, ALL EXISTING EXPOSED SURFACES TO RECEIVE PAINT OR NEW FINISHES, SEE FINISH
PLANS.
FURNITURE AND MOST APPLIANCES ARE FOR REFERENCE ONLY AND WILL BE OWNER
PROVIDED.
CONTRACTOR, SUBCONTRACTOR, VENDOR OR ANY OTHER PERSON PARTICIPATING
IN BIDDING THIS PROJECT SHALL BE RESPONSIBLE FOR INFORMATION CONTAINED
IN ANY AND ALL SHEETS OF DRAWINGS AND SPECIFICATIONS.
25 THE GENERAL CONTRACTOR IS TO PROVIDE BLOCKING AS REQUIRED FOR MOUNTING OF
WALL MOUNTED SHELVES, CABINETS, HC GRAB BARS AND PARTITION BRACES AND ALL
OTHER ITEMS IDENTIFIED ON THE EQUIPMENT OR ACCESSORY SCHEDULE. BLOCKING
SHALL BE FIRE TREATED WHERE REQUIRED BY THE BUILDING CODE.
26 THE GENERAL CONTRACTOR IS RESPONSIBLE FOR RECEIVING, UNLOADING, UNCRATING,
INSTALLATION AND HOOK-UP OF ALL OWNER FURNISHED ITEMS UNLESS NOTED
OTHERWISE ON THE DRAWINGS.
27 THE GENERAL CONTRACTOR IS TO ASSURE THAT NO REBAR OR REINFORCEMENT IS
PRESENT PRIOR TO CORE DRILLING OR PLACING BOLTS OR ANY OTHER ITEM WHICH
COULD DISTURB THE STRUCTURAL SLAB OR FOUNDATION WALLS.
28 PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR MATERIALS WHERE REQUIRED.
29 PROVIDE METAL TRIM OR CASING AT ALL EDGES OF PLASTER AND DRYWALL SURFACES
WHERE IT TERMINATES OR MEETS ANY OTHER MATERIAL, UNLESS NOTED OTHERWISE.
30 PROVIDE METAL CORNER TRIM AT ALL OUTSIDE CORNERS OF PLASTER AND DRYWALL
SURFACES.
31 ALL PENETRATIONS THROUGH ANY SURFACE SHALL BE THOROUGHLY SEALED WITH
APPROPRIATE SEALANT MATERIAL.
32 UNLESS OTHERWISE NOTED, ALL EXTERIOR AND INTERIOR METAL, TRIM, TREILLAGE,
RAILINGS, MOLDINGS, FRAMES, CASTING ETC., SHALL BE PAINTED.
33 FOR PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS, PROVIDE APPROVED
ASSEMBLIES WITH SELF CLOSING DEVICES FOR ANY PENETRATIONS IN RATED
CONSTRUCTION.
34 THE GC SHALL VERIFY LOCATIONS OF ALL CEILING& WALL ACCESS PANELS WITH
MECHANICAL, FIRE SPRINKLER AND PLUMBING PLANS. ACCESS PANELS SHALL BE
FURNISHED AND INSTALLED WITH A FIRE RATING EQUAL TO THE WALL OR CEILING
ASSEMBLY INTO WHICH THEY ARE TO BE INSTALLED. FINISH AND LOCATION SHALL BE
APPROVED BY THE ARCHITECT.
35 THE GC SHALL VERIFY DIMENSIONS OF ALL EQUIPMENT PADS & BASES WITH
EQUIPMENT MANUFACTURERS & SHALL VERIFY ALL SIZES AND LOCATIONS OF DUCT
OPENINGS ON ROOF AND INTERIOR SHAFTS.
DRAWING INDEX:
GENERAL
G000 COVER SHEET
G001 INDEX AND GENERAL NOTES
G002 ABBREVIATIONS, DIMENSIONING LEGEND, SYMBOLS
G005 FIRE & LIFE SAFETY PLAN
G010 ADA REQUIREMENTS
G011 ADA REQUIREMENTS
ARCHITECTURAL
AD001 LEVEL 3 - DEMOLITION FLOOR PLAN
AD002 LEVEL 3 CEILING PLAN DEMO
A101 LEVEL 3 - CONSTRUCTION FLOOR PLAN
A121 LEVEL 3 - FINISH PLAN
A131 LEVEL 3 - CEILING PLAN
A502 DETAILS - ACOUSTICS
A600 DOOR SCHEDULE & LEGEND
A700 SIGN SCHEDULE, TYPES, DETAILS
MECHANICAL
MG001 MECHANICAL LEGEND AND GENERAL NOTES
ME101 LEVEL 3 MECHANICAL FLOOR PLANS
ME501 MECHANICAL DETAILS
ELECTRICAL
EE001 SYMBOLS LEGEND & INDEX
EE002 SPECIFICATIONS
EE003 SPECIFICATIONS
EE004 RISER DIAGRAM
EE100 ELECTRICAL DEMOLITION PLANS
EE101 ELECTRICAL FLOOR & CEILING PLANS
EE600 ELECTRICAL SCHEDULES
EE701 TYPICAL MOUNTING DETAILS
EE702 ELECTRICAL DETAILS
MARK DATE DESCRIPTION
1 7/20/26 Addendum#1
DNUP
DN
UP
SEE SHEET G001 FOR DRAWING INDEX.
SEE SHEET AG000 FOR GENERAL NOTES AND ABBREVIATIONS.
DO NOT SCALE DRAWINGS.
CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE
BEGINNING WORK, AND SHALL REPORT TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR
OMISSIONS BEFORE BEGINNING WORK. SEE GENERAL NOTES AND SPECIFICATIONS.
F
G
E
D
I
C
B
A
1 2 3 4
SHIPPPING &
RECIEVING
OPEN OFFICE
CONFERENCE/TRAINING
OFFICE
7 SF
EL. CLOSET
A410
P2
P2
P3 P1
P2
06 01
05 02
1'-7 1/2" 2'-3"
'-7
/2
9"
2'-3"
EQ EQ
05 02
08 01
09 01
24 01
10 01
08 02
08 02
08 02
12" WOOD JOIST FLOOR12" WOOD JOIST FLOOR
08 021
12" WOOD JOIST FLOOR
CONTRACT LIMIT LINE
4 7/8"
5/8" GYP. BD. TYPE-X
3 5/8" STEEL STUD @ 16" O.C.
5/8" GYP. BD. TYPE-X
3 5/8" SOUND ATTENTION BLANKET
P1
P2
P3
P1- SOUND WALL
HEIGHT: 6" ABOVE CEILING
P2-SOUND WALL
HEIGHT: FULL HEIGHT
P3-NO SOUND ATTENTION
HEIGHT: 6" ABOVE CEILING
3-5/8" METAL STUD PARTITION WALL P1 - P2 - P3
A L L I
D E
A S
D
E S
IG
N
S A
R R
A N
G E
M E
N T S
A N
D P
L A
N S
I N
D
IC
A T E
D O
R R
E P
R E
S E
N T E
D B
Y T
H
IS
D R
A W
IN
G
A R
E O
W N
E D
B Y
A N
D T
H E
P R
O P
E R
T Y
O F
A
JC
A R
C H
IT
E
C T S
P C
A N
D W
E R
E C
R E
A T E
D E
V O
L V
E D
A
N D
D E
V E
L O
P E
D F
O R
U S
E O
N A
N D
I N
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N O
N E
O F
T H
E I D
E A
S
D E
S
IG
N S
A
R R
A N
G E
M E
N T S
O R
P L A
N S
S H
A L L B
E U
S E
D B
Y O
R D
IS
C
L O
S E
D T
O A
N Y
P E
R S
O N
F
IR
M
O
R C
O R
P O
R A
T
IO
N F
O R
A N
Y P
U R
P O
S E
W H
A T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T O
F A
JC
A
R C
H
IT
E C
T S
P C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
V E
P R
E C
E D
E N
C E
O V
E R
S C
A L E
D
IM
E N
S
IO
N S
C
O N
T R
A C
T O
R S
S H
A L L V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
L E
F O
R A
L L D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D
O F
A N
Y V
A R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E
A W
IN
G
S W
A R
N
IN
G R
E P
R O
D U
C T
IO
N H
E R
E O
F I S
A C
R
IM
IN
A
L O
F F
E N
S E
U N
D E
R
U
.S .C
S
E C
U
N A
U T H
O R
IZ
E
D D
IS
C
L O
S U
R E
M A
Y C
O N
S T
IT
U T E
T R
A D
E S
E C
R E
T M
IS
A
P P
R O
P R
IA
T
IO
N I N
V
IO
L A
T
IO
N O
F I .C
.2
-2 -3
-1
E T
S E
Q
A N
D O
T H
E R
L A
W S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
AHJ
A u to d e sk
D o cs
/2
-2
D
FC
M
-G O
E D
R e lo ca ti o n
T I/
G O
E D
R e lo ca ti o n
T I.r vt
/2
/2
:4
:5
P
M
7/8/2026
PERMIT SET
ajc
K. RIGBY
A101
2026-24
60 E SOUTH TEMPLE
SALT LAKE CITY, UT 84150
WORLD TRADE CENTER -
GOED TI
LEVEL 3 -
CONSTRUCTION FLOOR
PLAN
0'
SCALE : 1/8" = 1'-0"
8'4' 24'16'
KEYED NOTES:
05 02 ALIGN NEW WALL FINISH FLUSH WITH THE EXISTING COLUMN FINISH. PROVIDE
CONTINUOUS J-MOULDING AT THE TERMINATION EDGE. SEAL ALL JOINTS WITH
PAINTABLE SILICONE AS REQUIRED TO ACHIEVE A CLEAN, FINISHED APPEARANCE.
06 01 ADD 3/4" PLYWOOD BACKING FOR ELECTRICAL PANEL INSTALLATION AS REQ'D.
08 01 REUSE EXISTING DOOR, GLASS, FRAME AND HARDWARE.
08 02 APPLY COMMERCIAL WINDOW PRIVACY FILM TO THE BOTTOM AND MIDDLE
PORTIONS OF THE EXISTING GLAZING. INSTALL FILM ON THE EXTERIOR SIDE OF THE
ROOM. REMOVE EXISTING WINDOW FILM, IF PRESENT, PRIOR TO INSTALLATION OF
NEW PRIVACY FILM. REFER TO SHEET 15/A600 FOR ADDITIONAL INFORMATION.
09 01 DRYWALL CORNER BEADS ON ALL EDGES OF THE OPENING
10 01 SEMI-RECESSED FIRE EXTUINGUISHER CABINET
24 01 EXISTING DRINKING FOUNTAIN
GENERAL NOTES:
1/8" = 1'-0" ,1
LEVEL 3 - CONSTRUCTION FLOOR PLAN
n
MARK DATE DESCRIPTION
1 7/20/26 Addendum#1
WALL FINISH NOTES:
PATCH, REPAIR, AND FINISH EXISTING GYPSUM BOARD WALL SURFACES AFFECTED BY THE
REMOVAL OF EXISTING WALLS TO MATCH ADJACENT FINISHES. REFER TO DEMOLITION PLAN
1/AD001 FOR LOCATIONS.
UP
DNUP
DN
UP
DNUP
DN
UP
DNUP
DN
UP
SEE SHEET GI001 FOR DRAWING INDEX.
SEE SHEET GI002 FOR GENERAL NOTES AND ABBREVIATIONS.
DO NOT SCALE DRAWINGS.
CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE
BEGINNING WORK, AND SHALL REPORT TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR
OMISSIONS BEFORE BEGINNING WORK. SEE GENERAL NOTES AND SPECIFICATIONS.
FIELD VERIFY ALL DIMENSIONS BEFORE FABRICATION OF MILLWORK.
COORDINATE ALL MILLWORK WITH APPLIANCES BEFORE FABRICATION.
SEE INTERIOR ELEVATION SHEETS FOR ALL WALL TILE PATTERNS - COORDINATE PATTERN
LAYOUTS WITH ARCHITECT PRIOR TO CUTTING AND PLACEMENT OF ANY & ALL TILE.
PROVIDE A SMOOTH TRANSITION AT ALL CHANGES IN FLOOR MATERIAL - CONTRACTOR TO
INSTALL ALL FLOOR FINISHES AT SAME LEVEL, DESPITE DIFFERENCES IN THICKNESS.
ALL GYP. BD. CEILINGS SHALL BE PAINTED AS INDICATED IN FINISH LEGEND
ALL EXPOSED NON CONCRETE COLUMNS TO BE PAINTED TO MATCH ADJACENT WALLS.
EXPOSED METAL HANDRAILS, GUARDRAILS, HANDRAIL/GUARDRAIL SUPPORT SYSTEMS,
STAIR STRUCTURE, DUCTWORK, CONDUIT, PIPING, ETC NOT NOTED AS STAINLESS STEEL TO
BE PAINTED.
EXPOSED GYP. BD. CEILINGS SHALL BE PAINTED - REFER TO FINISH PLANS, REFLECTED
CEILING PLANS, & FINISH LEGEND FOR PAINT COLOR.
RATED WALL CONDITIONS SHALL REMAIN 5/8” TYPE-X GYP. BOARD. GYP. BOARD, BOTH RATED
AND NON-RATED, SHALL BE PAINTED WHERE EXPOSED - REFER TO FINISH LEGEND.
ALL SHOWER CEILINGS SHALL BE AT THE SAME ELEVATION AS THE ADJACENT CEILING, U.N.O.
PROVIDE SOLID BLOCKING/BACKING FOR ALL WALL MOUNTED ACCESSORIES.
FOR ALL FINISH MATERIALS SEE FINISH LEGEND ON SHEET SHEET AE620
FOR ACCESSORIES SEE SCHEDULE ON SHEET AE620. COORDINATE ALL FIXTURES WITH
MECHANICAL, PLUMBING, AND ELECTRICAL AS REQUIRED.
ALL EXSPOSED PIPES AT ADA FIXTURES SHOULD BE WRAPPED IN A PVC INSULATION.
WALL, FLOOR, BASE AND CEILING KEYNOTE: THIS SYMBOL, WHEN ATTACHED TO A WALL,
SHALL INDICATE THIS FINISH FOR THE ENTIRE LENGTH OF WALL FROM ONE INTERSECTION TO
THE NEXT AND NOT BE TERMINATED BY WINDOWS OR DOORS, U.N.O.
SEE SHEET AE620 FOR FINISH LEGEND.
FINISH NOTES
FINISH PLAN LEGEND
ROOM
ROOM #
FLOOR
BASE
WALLS
CEILINGS
DESIGNATED FINISH EXTENT
ROOM FINISH TAG - REFER TO FINISH LEGEND FOR MORE
INFORMATION
FINISH
CORNER GUARDS - REFER TO FINISH LEGEND AND FINISH DETAILS
FLOORING
CPT1 - CARPET TILE
MANUFACTURER: INTERFACE
SIZE: 10" X 40"
STYLE: 137880AK00 | STITCH IN TIME
COLOR: 105596 CHARCOAL STITCH
INSTALLATION METHOD: ASHLAR
WALL BASE
B1 4" RUBBER/VINYL BASE
MANUFACTURER: TARKETT
STYLE: COVE BASE
COLOR: 18 NAVY BLUE
SIZE: 4" TRADITIONAL (6" IN MAIN HALLWAYS)
WALLS
PT1 - GENERAL WALL, DOOR PANELS & DOOR FRAMES
MANUFACTURER: SHERWIN-WILLIAMS
COLOR: ALABASTER (SW 7008)
PT2 - OFFICE ACCENT WALLS
MANUFACTURER: SHERWIN-WILLIAMS
COLOR: REPOSE GREY (SW 7015)
PT3 - GREY-BLUE ACCENT WALLS
MANUFACTURER: SHERWIN-WILLIAMS
COLOR: STORM CLOUD (SW 6249)
PT4 - NAVY BLUE ACCENT WALLS
MANUFACTURER: SHERWIN-WILLIAMS
COLOR: ANCHORS AWEIGH (SW 9179)
FINISH NOTE:
REUSE EXISTING CARPET TILES WHEREVER POSSIBLE. CONTRACTOR SHALL PROVIDE NEW
MATERIALS ONLY AFTER EXISTING MATERIALS HAVE BEEN FULLY UTILIZED OR ARE NO LONGER
SUITABLE FOR REUSE.
F
G
E
D
I
C
B
A
1 2 3 4
SHIPPPING &
RECIEVING
CPT1
B1
PT1
C1/C2
OPEN OFFICE
CPT1
B1
PT1
C1
CONFERENCE/TRAINING
CPT1
B1
PT1
C2
OFFICE
CPT1
B1
PT1
C1
09 02
A L L I
D E
A S
D
E S
IG
N
S A
R R
A N
G E
M E
N T S
A N
D P
L A
N S
I N
D
IC
A T E
D O
R R
E P
R E
S E
N T E
D B
Y T
H
IS
D R
A W
IN
G
A R
E O
W N
E D
B Y
A N
D T
H E
P R
O P
E R
T Y
O F
A
JC
A R
C H
IT
E
C T S
P C
A N
D W
E R
E C
R E
A T E
D E
V O
L V
E D
A
N D
D E
V E
L O
P E
D F
O R
U S
E O
N A
N D
I N
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N O
N E
O F
T H
E I D
E A
S
D E
S
IG
N S
A
R R
A N
G E
M E
N T S
O R
P L A
N S
S H
A L L B
E U
S E
D B
Y O
R D
IS
C
L O
S E
D T
O A
N Y
P E
R S
O N
F
IR
M
O
R C
O R
P O
R A
T
IO
N F
O R
A N
Y P
U R
P O
S E
W H
A T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T O
F A
JC
A
R C
H
IT
E C
T S
P C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
V E
P R
E C
E D
E N
C E
O V
E R
S C
A L E
D
IM
E N
S
IO
N S
C
O N
T R
A C
T O
R S
S H
A L L V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
L E
F O
R A
L L D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D
O F
A N
Y V
A R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E
A W
IN
G
S W
A R
N
IN
G R
E P
R O
D U
C T
IO
N H
E R
E O
F I S
A C
R
IM
IN
A
L O
F F
E N
S E
U N
D E
R
U
.S .C
S
E C
U
N A
U T H
O R
IZ
E
D D
IS
C
L O
S U
R E
M A
Y C
O N
S T
IT
U T E
T R
A D
E S
E C
R E
T M
IS
A
P P
R O
P R
IA
T
IO
N I N
V
IO
L A
T
IO
N O
F I .C
.2
-2 -3
-1
E T
S E
Q
A N
D O
T H
E R
L A
W S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
AHJ
A u to d e sk
D o cs
/2
-2
D
FC
M
-G O
E D
R e lo ca ti o n
T I/
G O
E D
R e lo ca ti o n
T I.r vt
/2
/2
:4
:5
P
M
7/8/2026
PERMIT SET
ajc
K. RIGBY
A121
2026-24
60 E SOUTH TEMPLE
SALT LAKE CITY, UT 84150
WORLD TRADE CENTER -
GOED TI
LEVEL 3 - FINISH PLAN
0'
SCALE : 1/8" = 1'-0"
8'4' 24'16'
1/8" = 1'-0" ,1
LEVEL 3 - FINISH PLAN
n
MARK DATE DESCRIPTION
1 7/20/26 Addendum#1
KEYED NOTES:
09 02 PAINT THESE WALLS ON HALWAY SIDE CORNER TO CORNER WITH PAINT PT1
F
G
E
D
I
C
B
A
1 2 3 4 5
'-0
'-0
'-1
'-1
'-0
'-6
'-6
33'-8" 4'-6" 39'-10" 4'-6"
OFFICE
OPEN OFFICE
SHIPPPING &
RECIEVING
CONFERENCE/TRAINING
C1
9'-0"
C1
9'-0"
C1
9'-0"
C1
9'-0"
LAY-IN CEILING FLUORESCENT FIXTURE. SEE
ELECTRICAL PLAN FOR SIZE AND TYPE.
LIGHTING DEVICES. SEE ELECTRICAL PLAN
FOR SIZE AND TYPE.
SUPPLY, RETURN & EXHAUST
DIFFUSERS/GRILLES. SEE MECHANICAL.
SUPPLY
DIFFUSER
LIFE SAFETY DEVICES. SEE ELECTRICAL
PLAN.
S
LIFE SAFETY DEVICES. SEE ELECTRICAL
PLAN.
FIRE
ALARM
EXIT SIGN
DATA DEVICES
ELECTRICAL PLAN FOR TYPE.
THIS IS A REFLECTED CEILING PLAN AND IS NOT TO BE INTENDED TO BE A LIGHTING PLAN. NO
WALL MOUNTED LIGHTING FIXTURES OR OTHER WALL MOUNTED APPURTENANCES ARE
SHOWN. SEE THE LIGHTING PLAN FOR ALL LIGHTING AND EGRESS SIGNS, SIZE AND TYPES OF
ELECTRICAL FIXTURES ETC. SEE MECHANICAL PLANS FOR ALL CEILING MOUNTED
DIFFUSERS/GRILLES ETC.
SYMBOL LEGEND
RETURN
GRILE
MOTION
SENSOR
DATA DEVICE
DC
DIMMING
CONTROL
C1 - NEW ACOUSTIC CEILING TILE - 24"x24"
C1
CEILING TYPES
SEE SHEET G001 FOR DRAWING INDEX.
SEE SHEET AG000 FOR GENERAL NOTES AND ABBREVIATIONS.
DO NOT SCALE DRAWINGS.
CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE
BEGINNING WORK, AND SHALL REPORT TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR
OMISSIONS BEFORE BEGINNING WORK. SEE GENERAL NOTES AND SPECIFICATIONS.
A L L I
D E
A S
D
E S
IG
N
S A
R R
A N
G E
M E
N T S
A N
D P
L A
N S
I N
D
IC
A T E
D O
R R
E P
R E
S E
N T E
D B
Y T
H
IS
D R
A W
IN
G
A R
E O
W N
E D
B Y
A N
D T
H E
P R
O P
E R
T Y
O F
A
JC
A R
C H
IT
E
C T S
P C
A N
D W
E R
E C
R E
A T E
D E
V O
L V
E D
A
N D
D E
V E
L O
P E
D F
O R
U S
E O
N A
N D
I N
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N O
N E
O F
T H
E I D
E A
S
D E
S
IG
N S
A
R R
A N
G E
M E
N T S
O R
P L A
N S
S H
A L L B
E U
S E
D B
Y O
R D
IS
C
L O
S E
D T
O A
N Y
P E
R S
O N
F
IR
M
O
R C
O R
P O
R A
T
IO
N F
O R
A N
Y P
U R
P O
S E
W H
A T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T O
F A
JC
A
R C
H
IT
E C
T S
P C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
V E
P R
E C
E D
E N
C E
O V
E R
S C
A L E
D
IM
E N
S
IO
N S
C
O N
T R
A C
T O
R S
S H
A L L V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
L E
F O
R A
L L D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D
O F
A N
Y V
A R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E
A W
IN
G
S W
A R
N
IN
G R
E P
R O
D U
C T
IO
N H
E R
E O
F I S
A C
R
IM
IN
A
L O
F F
E N
S E
U N
D E
R
U
.S .C
S
E C
U
N A
U T H
O R
IZ
E
D D
IS
C
L O
S U
R E
M A
Y C
O N
S T
IT
U T E
T R
A D
E S
E C
R E
T M
IS
A
P P
R O
P R
IA
T
IO
N I N
V
IO
L A
T
IO
N O
F I .C
.2
-2 -3
-1
E T
S E
Q
A N
D O
T H
E R
L A
W S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
AHJ
A u to d e sk
D o cs
/2
-2
D
FC
M
-G O
E D
R e lo ca ti o n
T I/
G O
E D
R e lo ca ti o n
T I.r vt
/2
/2
:4
:5
P
M
7/8/2026
PERMIT SET
ajc
K. RIGBY
A131
2026-24
60 E SOUTH TEMPLE
SALT LAKE CITY, UT 84150
WORLD TRADE CENTER -
GOED TI
LEVEL 3 - CEILING
PLAN
1/8" = 1'-0" ,1
LEVEL 1 CEILING PLAN
KEYED NOTES:
0'
SCALE : 1/8" = 1'-0"
8'4' 24'16' n
GENERAL NOTES AND LEGENDS:
FINISH PLAN LEGEND:
CEILING
CL1 - LAY-IN CEILING (TO MATCH EXISTING)
POSSIBLE EXISTING:
MANUFACTURER: ARMSTRONG
SIZE: 24" X 24"
STYLE: CIRRUS, TEGULAR
INSTALLATION METHOD: STANDARD HEAVY DUTY CEILING GRID
MARK DATE DESCRIPTION
1 7/20/26 Addendum#1
CEILING FINISH NOTE:
REUSE EXISTING CEILING TILES & SUSPENDED CEILING GRID, WHEREVER POSSIBLE.
CONTRACTOR SHALL PROVIDE NEW MATERIALS ONLY AFTER EXISTING MATERIALS HAVE BEEN
FULLY UTILIZED OR ARE NO LONGER SUITABLE FOR REUSE.
HM-A
SALVAGED HM EGRESS
DOOR. REPAINT.
HM-B
S E E S
C H
E D
U
LE
2"
SCHEDULE
SEE 2"
'-0
8'-6"
EXISTING HOLLOW METAL
FRAME, WRAPS WALL/
REPAINT.
A600
A600
A600
A600
A600
A600
A600
SIM.
'-8
APPLY COMMERCIAL WINDOW
PRIVACY FILM IN BOTTOM AND
MIDDLE PORTION OF THE
GLAZING.
FILM SHOULD BE APPLIED
OUTSIDE OF THE ROOM. TYP.
WD
EXISTING SOLID WOOD
DOOR. PATCH AND
REPAIR. REPAINT.
FRAME ANCHOR
WALL TYPES
VARIES, SEE
SEE WALL TYPES
METAL STUD HEADER
PAINTABLE SEALANT, BOTH SIDES
HOLLOW METAL FRAME, PAINT
DOOR, SEE SCHEDULE
/8
1/2"
/8
GLASS AS SCHEDULED
HM GLAZING STOP
HM FRAME
LINE OF ASSEMBLY
BEYOND
RESILIENT GASKET. TYP.
DOOR AS SCHEDULED
GLASS AS SCHEDULED
HM GLAZING STOP
HM FRAME
LINE OF ASSEMBLY
BEYOND
RESILIENT GASKET. TYP.
GLASS AS SCHEDULED
2"
TYP.
4"
HOLLOW METAL FRAME, PAINT
JAMB ANCHOR
W A
LL
T Y P
E S
V A R
IE
S
, S E
E
(2) 18 GA. METAL STUDS PER JAMP,
TYP.
PAINTABLE SEALANT, BOTH SIDES
SEE WALL TYPES
DOOR, SEE SCHEDULE
ABUTTING WALL WHERE INDICATED
GLASS AS SCHEDULED
HM GLAZING STOP
HM FRAME
RESILIENT GASKET. TYP.
HM SUPPORT BRACKET
24" O.C. MAX.
ATTACH W/ MIN (2) 1/8"
PDF MAX. 24" O.C. MIN.
1-1/4" EMBED
LINE OF ASSEMBLY
BEYOND
A L L I
D E
A S
D
E S
IG
N
S A
R R
A N
G E
M E
N T S
A N
D P
L A
N S
I N
D
IC
A T E
D O
R R
E P
R E
S E
N T E
D B
Y T
H
IS
D R
A W
IN
G
A R
E O
W N
E D
B Y
A N
D T
H E
P R
O P
E R
T Y
O F
A
JC
A R
C H
IT
E
C T S
P C
A N
D W
E R
E C
R E
A T E
D E
V O
L V
E D
A
N D
D E
V E
L O
P E
D F
O R
U S
E O
N A
N D
I N
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N O
N E
O F
T H
E I D
E A
S
D E
S
IG
N S
A
R R
A N
G E
M E
N T S
O R
P L A
N S
S H
A L L B
E U
S E
D B
Y O
R D
IS
C
L O
S E
D T
O A
N Y
P E
R S
O N
F
IR
M
O
R C
O R
P O
R A
T
IO
N F
O R
A N
Y P
U R
P O
S E
W H
A T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T O
F A
JC
A
R C
H
IT
E C
T S
P C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
V E
P R
E C
E D
E N
C E
O V
E R
S C
A L E
D
IM
E N
S
IO
N S
C
O N
T R
A C
T O
R S
S H
A L L V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
L E
F O
R A
L L D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D
O F
A N
Y V
A R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E
A W
IN
G
S W
A R
N
IN
G R
E P
R O
D U
C T
IO
N H
E R
E O
F I S
A C
R
IM
IN
A
L O
F F
E N
S E
U N
D E
R
U
.S .C
S
E C
U
N A
U T H
O R
IZ
E
D D
IS
C
L O
S U
R E
M A
Y C
O N
S T
IT
U T E
T R
A D
E S
E C
R E
T M
IS
A
P P
R O
P R
IA
T
IO
N I N
V
IO
L A
T
IO
N O
F I .C
.2
-2 -3
-1
E T
S E
Q
A N
D O
T H
E R
L A
W S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
AHJ
A u to d e sk
D o cs
/2
-2
D
FC
M
-G O
E D
R e lo ca ti o n
T I/
G O
E D
R e lo ca ti o n
T I.r vt
/2
/2
:4
:5
P
M
7/8/2026
PERMIT SET
ajc
K. RIGBY
A600
2026-24
60 E SOUTH TEMPLE
SALT LAKE CITY, UT 84150
WORLD TRADE CENTER -
GOED TI
DOOR SCHEDULE &
LEGEND
DOOR & FRAME SCHEDULE
DOOR
NO.
PANEL FRAME GENERAL INFO
COMMENTSW
ID
TH
H E
IG
H T
TY
P
E
FI
N
IS
H
TY
P
E
FI
N
IS
H
H A R
D W
A R
E S
E T
F
IR
E R
A
TI
N G
A C
O U
S
TI
C R
A
TI
N G
102 WD HM-B REUSE 0 SALVAGED HM GLAZED FRAME AND DOOR PANEL
104 3'-0" 7'-0" WD HM-A 0 EXISTING DOOR PROTECT DURING ALL PHASES OF CONSTRUCTION
105 WD HM-B 0 EXISTING DOOR PROTECT DURING ALL PHASES OF CONSTRUCTION
106 3'-0" 7'-0" WD HM-A LOCKING
REMOVE EXISTING PANIC HARDWARE. PATCH AND REPAINT DOOR PANEL.
PROVIDE NEW LOCKING SET.
1/4" = 1'-0" ,15
LEGEND - FRAME TYPES
1/4" = 1'-0" ,16
LEGEND - DOOR TYPES - WOOD PANELS
1. BASIS OF DESIGN INDICATED BELOW. SEE SPECIFICATIONS. SUBSTITUTIONS MUST BE APPROVED BY ARCHITECT.
2. NOTE: CONTRACTOR AND DOOR SUPPLIER TO COORDINATE DOOR UNDER-CUTS WITH MECHANICAL DRAWINGS FOR ADEQUATE VENTILATION.
3. DOOR HARDWARE SHALL MEET THE REQUIREMENTS OF IBC 1010.1.9.1. HARDWARE SHALL NOT REQUIRE PINCHING, TIGHT GRASPING, OR TWISTING
OF THE WRIST IN ORDER TO OPERATE.
4. FIELD VERIFY ALL DOOR OPENINGS AND CLEARANCES PRIOR TO DOOR FABRICATION AND INSTALLATION.
5. VERIFY ALL THROAT WIDTHS OF FRAMES WITH WALL TYPES AS INDICATED ON PLAN DRAWINGS.
6. REFER TO SPECIFICATION FOR DOOR HARDWARE SETS.
7. REFER TO FINISH SCHEDULE FOR DOOR AND FRAME FINISH DESCRIPTIONS
3" = 1'-0" , DWG REF: A60010
DOOR - HM HEAD @ GYP BD
3" = 1'-0" , DWG REF: A6009
DOOR - HM JAMB @ GYP BD
3" = 1'-0" , DWG REF: A6007
DOOR - HM HEAD @ TRANSOM GLASS
3" = 1'-0" , DWG REF: A6006
DOOR - HM JAMB @ GLASS
3" = 1'-0" , DWG REF: A6005
DOOR - HM SILL @ GLASS
3'-0" 7'-0" REFINISH
3'-0" 7'-0"
MARK DATE DESCRIPTION
1 7/20/26 Addendum#1
UP
SHIPPPING &
RECIEVING
OPEN OFFICE
CONFERENCE/TRAINING
OFFICE
EL. CLOSET
A R
R O
W D
IR
E
C T
IO
N
'-0
9"
SEE G011 FOR ADA
SIGNAGE REQUIREMENTS
NOTE:
1. PROVIDE FIRE EXTINGUISHER SIGN PER OSHA/IFC
REQUIREMENTS
2. ALL TEXT TO BE IN CENTURY GOTHIC
9"
/2
M
IN
STAINLESS STEEL PLATE W/
SQUARE EDGES,
MECHANICALLY FASTENED TO
THE WALL W/ CONCEALED
FASTENERS, COORDINATE TYPE
OF FASTENER WITH ARCHITECT
GRADE 2 BRAILLE,
BLACK FINISH
RAISED LETTERS , BLACK
FINISH
EXIT
TYPE - B
9"
OFFICE
1" RAISED LETTERS
AND GRADE 2
BRAILLE, BLACK
FINISH
TYPE - C
STAINLESS STEEL
PLATE W/ SQUARE
EDGES, MECHANICALLY
FASTENED TO THE
WALL W/ CONCEALED
FASTENERS,
COORDINATE TYPE OF
FASTENER WITH
ARCHITECT
1'-3"
/2
/2
STAINLESS STEEL PLATE W/
SQUARE EDGES,
MECHANICALLY FASTENED TO
THE WALL W/ CONCEALED
FASTENERS, COORDINATE TYPE
OF FASTENER WITH ARCHITECT
RAISED LETTERS , BLACK
FINISH
UTAH OFFICE OF
TOURISM AND UTAH
FILM COMMISSION
TYPE - A
DIRECTIONAL SIGN - ARROW TO POINT TOWARD GOED OFFICE SPACE EXIT SIGN - INSTALL NEXT TO EGRESS DOOR/OPENING
TYPICAL ROOM SIGN
GRADE 2 BRAILLE,
BLACK FINISH
UTAH OFFICE OF TOURISM
AND UTAH FILM COMMISSION LOGO
TYPE - D
AGENCY ENTRANCE WALL PLAQUE TO MATCH EXISTING TYPE - E SIGNAGE
NOTE:
LOGO AND LETTERING FONT/SIZE TO BE PROVIDED BY THE OWNER
TYPE - E
MODIFY EXISTING SIGNAGE
TO ADD GOED SIGNAGE.
COORDINATE WITH THE
OWNER FOR AGENCY TITLE
V E
R
IF
Y
M A
TC
H E
X
IS
TI
N
G T
Y P
E -E
S
IG
N A G
E
VERIFY - MATCH EXISTING TYPE-E SIGNAGE
A L L I
D E
A S
D
E S
IG
N
S A
R R
A N
G E
M E
N T S
A N
D P
L A
N S
I N
D
IC
A T E
D O
R R
E P
R E
S E
N T E
D B
Y T
H
IS
D R
A W
IN
G
A R
E O
W N
E D
B Y
A N
D T
H E
P R
O P
E R
T Y
O F
A
JC
A R
C H
IT
E
C T S
P C
A N
D W
E R
E C
R E
A T E
D E
V O
L V
E D
A
N D
D E
V E
L O
P E
D F
O R
U S
E O
N A
N D
I N
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N O
N E
O F
T H
E I D
E A
S
D E
S
IG
N S
A
R R
A N
G E
M E
N T S
O R
P L A
N S
S H
A L L B
E U
S E
D B
Y O
R D
IS
C
L O
S E
D T
O A
N Y
P E
R S
O N
F
IR
M
O
R C
O R
P O
R A
T
IO
N F
O R
A N
Y P
U R
P O
S E
W H
A T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T O
F A
JC
A
R C
H
IT
E C
T S
P C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
V E
P R
E C
E D
E N
C E
O V
E R
S C
A L E
D
IM
E N
S
IO
N S
C
O N
T R
A C
T O
R S
S H
A L L V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
L E
F O
R A
L L D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D
O F
A N
Y V
A R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E
A W
IN
G
S W
A R
N
IN
G R
E P
R O
D U
C T
IO
N H
E R
E O
F I S
A C
R
IM
IN
A
L O
F F
E N
S E
U N
D E
R
U
.S .C
S
E C
U
N A
U T H
O R
IZ
E
D D
IS
C
L O
S U
R E
M A
Y C
O N
S T
IT
U T E
T R
A D
E S
E C
R E
T M
IS
A
P P
R O
P R
IA
T
IO
N I N
V
IO
L A
T
IO
N O
F I .C
.2
-2 -3
-1
E T
S E
Q
A N
D O
T H
E R
L A
W S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
AHJ
A u to d e sk
D o cs
/2
-2
D
FC
M
-G O
E D
R e lo ca ti o n
T I/
G O
E D
R e lo ca ti o n
T I.r vt
/2
/2
:4
:5
P
M
7/8/2026
PERMIT SET
ajc
K. RIGBY
A700
2026-24
60 E SOUTH TEMPLE
SALT LAKE CITY, UT 84150
WORLD TRADE CENTER -
GOED TI
SIGN SCHEDULE,
TYPES, DETAILS
1/16" = 1'-0" ,1
LEVEL 3 - SIGNAGE PLAN
1/2" = 1'-0" ,2
SIGNAGE ELEVATION MOUNTING TYP.
3" = 1'-0" ,3
SIGNAGE TYPES
A
B
B
C
C
C C
D
MARK DATE DESCRIPTION
1 7/20/26 Addendum#1
E
A
WHW ENGINEERING, LLC.
MECHANICAL
& PLUMBING
E N G I N E E R I N G
WHW ENGINEERING LLC
733 West 9000 South - Sandy, Utah - 84070
p. 801.466.4021
July 16, 2026
AJC ARCHITECTS
703 EAST 1700 SOUTH
SALT LAKE CITY, UT 84105
ATTN: Heber Slabbert RE: GOED - Addendum #1
Dear Heber, Please see below for modifications to the project listed above included in Addendum #1.
I. CHANGES/CLARIFICATIONS TO DRAWINGS:
a. See the attached updated ME101. Duct demo and new has changed. Thermostats shifted. No new equipment or GRD’s just duct changes.
We appreciate the opportunity to work with you on this project. If you need additional information or have any questions, please do not hesitate to contact our office. Thank you.
Sincerely, Brad Lash WHW Engineering
F
D
I
C
1 2 3
F
E
D
I
C
1 2 3
VAV
336E
VAV
640E
VAV
332E
10"ø SA
18"x12" SA
10"ø SA
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
100 EXIST
EXIST
EXIST
EXIST
VAV
323E
EXIST
EXIST
EXIST
EXIST
EXIST
VAV
333E
S
VAV-332E
S
VAV-333E
S
VAV-336E
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
S
VAV-640E
EXIST
SHIPPPING &
RECIEVING
OPEN OFFICE
OFFICE
CONFERENCE/TRAINING
EXIST
EXIST
EXIST
210 S
EXIST
EXIST
BRADLEY D.
LASH
No. 8681468
P R
O F
E
SS IONAL ENG
IN
E
E R
S T
A T E
O F U
T
A H
A L L I
D E
A S
D
E S
IG
N
S A
R R
A N
G E
M E
N T S
A N
D P
L A
N S
I N
D
IC
A T E
D O
R R
E P
R E
S E
N T E
D B
Y T
H
IS
D R
A W
IN
G
A R
E O
W N
E D
B Y
A N
D T
H E
P R
O P
E R
T Y
O F
A
JC
A R
C H
IT
E
C T S
P C
A N
D W
E R
E C
R E
A T E
D E
V O
L V
E D
A
N D
D E
V E
L O
P E
D F
O R
U S
E O
N A
N D
I N
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N O
N E
O F
T H
E I D
E A
S
D E
S
IG
N S
A
R R
A N
G E
M E
N T S
O R
P L A
N S
S H
A L L B
E U
S E
D B
Y O
R D
IS
C
L O
S E
D T
O A
N Y
P E
R S
O N
F
IR
M
O
R C
O R
P O
R A
T
IO
N F
O R
A N
Y P
U R
P O
S E
W H
A T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T O
F A
JC
A
R C
H
IT
E C
T S
P C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
V E
P R
E C
E D
E N
C E
O V
E R
S C
A L E
D
IM
E N
S
IO
N S
C
O N
T R
A C
T O
R S
S H
A L L V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
L E
F O
R A
L L D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D
O F
A N
Y V
A R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E
A W
IN
G
S W
A R
N
IN
G R
E P
R O
D U
C T
IO
N H
E R
E O
F I S
A C
R
IM
IN
A
L O
F F
E N
S E
U N
D E
R
U
.S .C
S
E C
U
N A
U T H
O R
IZ
E
D D
IS
C
L O
S U
R E
M A
Y C
O N
S T
IT
U T E
T R
A D
E S
E C
R E
T M
IS
A
P P
R O
P R
IA
T
IO
N I N
V
IO
L A
T
IO
N O
F I .C
.2
-2 -3
-1
E T S
E Q
A
N D
O T H
E R
L A
W S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
07/08/26
A u to d e sk
D o cs
/2
-2
D
F C
M -G
O E
D R e lo ca ti o n
T I/
G
O E
D R e lo ca ti o n
T I v
M
P .r vt
/1
/2
:3
:0
P
M
07/09/2026
PERMIT SET
SG
BDL
ME101
26105
60 E SOUTH TEMPLE
SALT LAKE CITY, UT 84150
WORLD TRADE CENTER -
GOED TENANT
IMPROVEMENT
LEVEL 3 MECHANICAL
FLOOR PLANS
SHEET NOTES
1 RELOCATE THE EXISTING THERMOSTATS TO THIS
APPROXIMATE LOCATION AND MOUNT AT 48" AFF.
3/16" = 1'-0"
LEVEL 3 MECHANICAL DEMOLITION
FLOOR PLANS
3/16" = 1'-0"
LEVEL 3 LARGE SCALE MECHANICAL
FLOOR PLANS
GENERAL NOTES
1. THE INTENT IS TO REUSE THE EXISTING SUPPLY
DIFFUSERS AND RETURN GRILLES AND MODIFY DUCTWORK
AS NEEDED FOR THE NEW LAYOUT.
2. PROVIDE FULL TEST AND BALANCE ON THE AIR SIDE OF
EACH OF THE VAV SYSTEMS THAT ARE AFFECTED BY THE
MODIFICATIONS.
MARK DATE DESCRIPTION
1 07/21/26 ADD#1
1" = 40'-0"
KEYPLAN
File details come from the government source that posted it. Updated .