4-Attachment 1.pdf

PDF 515 KB Posted

Attached to
Vertical Turbine Pumps Maintenance Services and Parts
Solicitation number
ITB-25-00343
Issued by
Hillsborough County, Florida

About this file

This document is a Vertical Turbine Pump Inventory List for eight (8) water and wastewater treatment facilities located in the Tampa, Florida area, including South County Regional AWWTP, Valrico AWWTP, Falkenburg AWWTP, NW Regional Wastewater Reclamation AWWTP, Van Dyke AWWTP, Dale Mabry Reclaimed, FawnRidge, and Lake Park. The inventory comprehensively details 24 distinct pump configurations across these facilities, with quantities ranging from one to six pumps per location. The pumps are primarily vertical turbine style, manufactured by companies including Flowserve, Ruhrpumpen, Pentair Aurora Layne/Verti-Line, and Peerless, with varying specifications such as horsepower (ranging from 15 to 300 HP), gallons per minute (GPM) from 750 to 6400, and total dynamic head (TDH) between 30 and 232 feet.

The inventory provides granular technical details for each pump, including serial numbers, manufacturer models, revolutions per minute (RPM), and number of stages. The pumps serve critical functions across these facilities, including effluent management, filter feed, backwash, non-potable water distribution, reclaim water processing, and booster operations. Most pumps are multi-stage vertical turbine designs, with horsepower ranging from 10 to 300 HP and designed for specific operational requirements at each treatment facility. The comprehensive documentation suggests this is likely part of a maintenance, replacement, or procurement process for municipal water and wastewater infrastructure in Hillsborough County, Florida.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 1- Vertical Turbine Pump Inventory List

(8) Facilities are:

South County Regional AWWTP: 520 Teco Rd., Ruskin, FL, 33570 Valrico AWWTP: 1167 N. Dover Rd., Dover, FL, 33527 Falkenburg AWWTP: 102 N. Falkenburg Rd. , Tampa, FL 33619 NW Regional Wastewater Reclaim AWWTP: 11005 Dale Stitik Dr., Tampa, FL, 33626 Van Dyke AWWTP: 19140 Ramblewood Rd., Odessa, FL, 33556 Dale Mabry Reclaimed: 13055 Delwood Rd., Tampa, FL, 33624 FawnRidge: 9600 Citrus Park Drive, Tampa, FL, 33626 Lake Park- New Pumps: 17316 N. Dale Mabry Hwy, Tampa, FL, 33626

Pump Locations, Quantities, & Types

1. South County Regional AWWTP Effluent Pumps Quantity of six (6)

Serial: 1211NSH01489-1 thru 1211SNH01489-6 MFG: Flowserve Model: 18ENH-1

RPM: 1185

TDH: 52

GPM: 3470

HP: 75

Single stage

2. South County Regional AWWTP Filter Feed Pumps Quantity of six (6)

Serial: 1306MS005741-1 through 1306MS005741-6 MFG: Flowserve Model: 16MVX

RPM: 890

TDH: 20

GPM: 3470

HP: 30

3. South County Regional AWWTP Non-Potable Water Pumps Quantity of two (2)

Serial: 1211NSH01489-3 & 1211NSH01489-2 MFG: Flowserve Model: 10ELL-5

RPM: 705

TDH: 210

GPM: 300

HP: 25

4. South County Regional AWWTP Non-Potable Water Pump Quantity of one (1)

Serial: 1211NSH01489-1 MFG: Flowserve Model: 8L12-8

RPM: 705

TDH: 210

GPM: 300

HP: 10

5. Valrico AWTP Filter Feed Pumps Quantity of five (5)

Serial: 0807MS004552-1, 0807MS004552-2, 0807MS004562-2, 0807MS004562-1, 0807MS004562-3

MFG: Flowserve Model: 20ENH-1

RPM: 885

TDH: 33

GPM: 4800

6. Valrico AWTP Effluent Pumps Quantity of four (4)

Serial: 0807MS004553-3, 0807MS004553-1, 0807MS004553-4, 0807MS004553-2

MFG: Flowserve Model: 22ENL-1

RPM: 1185

TDH: 54

GPM: 6400

HP: 125

7. Valrico AWTP Back Wash Pumps Quantity of two (2) Serial: 2388027-1, 2388027-0

MFG: AURORA LAYNE/VERTI

Model: 19GM/1100AW

RPM: 1190

TDH: 41

GPM: 4000

HP: 60

8. Falkenburg AWTP Effluent Pumps (2 Jockey pumps & 4 Main)

a) 2 jockey pumps Serial: 1807NSH02553-1, 1807NSH02553-2 MFG: Flowserve

Model: 15EHM-1

RPM: 1775

TDH: 75

GPM: 3600

HP: 125

b) 4 Main Effluent Pumps Serial: 0208MS001996-2, 0208MS001996-1, 0805MS004540-1, 0805MS004540-2 MFG: Flowserve Model: 22ENM-1

RPM: 1190

TDH: 65

GPM: 7200

HP: 150

9. Falkenburg NPW Pumps Quantity of two (2)

Serial: 0805MS004541-1, 0805MS004541-2 MFG: Flowserve Model: 12FJH-3

RPM: 1780

TDH: 232

GPM: 960

HP: 100

10. Falkenburg Reject Return Pumps Quantity of three (3) Serial: 0805MS004539-1, 0805MS004539-2, 0805MS004539-3 MFG: Flowserve Model: 14ENL-1/10LF

RPM: 1780

TDH: 52

GPM: 1600

HP: 40

11. NW. Regional Wastewater Reclamation: 3W pumps. Quantity of two (2) Peabody Floway

Ser: 89-02201 & 89-02202 Model: 14 FKH

RPM: 1800

GPM: 2500

HP: 200

TDH: 250’

# of Stages: 3

12. NW. Regional Wastewater Reclamation: Backwash Pumps. Quantity of two (2)

Deming Pump Ser: MF-1383 & MF-1384 Equip. ID: 4830-71200999 Type: Vertical Turbine Model: 4830

RPM: 1170

GPM: 2900

HP: 40

TDH: 30’

# of Stages: 2

13. NW. Regional Wastewater Reclamation: EFF pumps Quantity of two (2)

Peabody Floway Ser: N/A Type: BKH Model: N/A Size: 22

RPM: 1200

GPM: 5200

HP: 100

TDH: 49

# of Stages: 1

14. NW. Regional Wastewater Reclamation: EFF pumps Quantity of three (3)

Peerless Ser: 744452ZA Type: N/A Model: 20HH

RPM: 1180

GPM: 5200

HP: 100

TDH: N/A

# of Stages: N/A

15. NW. Regional Wastewater Reclamation: EFF pumps Quantity of five (5)

Flowserve Ser: 18XXMS006686-1 Thru 18XXMS006686-5 Type: VTP Model: 26ELL-3

RPM: 1185

GPM: 5500

HP: 250

TDH: 110

# of Stages:3

16. NW. Regional Wastewater Reclamation: Reclaim Jockey pumps Quantity of three (3)

Ser: 1807NSH02419-1 through 1807NSH02419-3 Type: VTP Model: 15EMM-2

RPM: 1775

GPM: 2000

HP: 125

TDH: 185

# of Stages:2

17. NW. Regional Wastewater Reclamation: Reclaim pumps Quantity of three (3)

Ser: 1807NSH02420-1 through 1807NSH02420-3 Type: VTP Model: 20EKH-1

RPM: 1780

GPM: 4500

HP: 300

# of Stages:1

18. Van Dyke: EFF pumps Quantity of three (3)

Ruhrpumpen Ser: 400792-1 thru -3 Type: Vertical Turbine Model: VTP Size: 12B90

RPM: 1800

GPM: 875

HP: 15

TDH: 46.2

# of Stages: 1

19. Dale Mabry Reclaimed Jockey Quantity of one (1)

Ser: N/A Type: Vertical Turbine Model: 12EML-3 Size: 6LF-16

RPM: 1785

GPM: 750

HP: 50

20. Dale Mabry Reclaimed Intermediate Quantity of one (1)

Ser: N/A Type: Vertical Turbine Model: 15EMM-5 Size: 8LF-16

RPM: 1190

GPM: 1500

HP: 100

21. Dale Mabry Reclaimed Booster Quantity of four (4)

Ser: N/A Type: Vertical Turbine Model: 20EKH Size: 12LF-20

RPM: 1200

GPM: 3200

HP: 200

22. Fawn Ridge Water Plant Quantity of five (5) Pentair Aurora Layne/Verti-Line

Ser: 10532636 through 10532640 Type: Vertical Turbine Model: 19GM-1100AW Size: 20”

RPM: 1770

GPM: 4340

HP: 250

23. Fawn Ridge Water Plant. Quantity of one (1)

Lane & Bowler Inc.

Ser: 112318 Type: Vertical Turbine Model: 20FB20-30B Size: 20”

RPM: 1770

GPM: 1600

HP: 150

24. Lake Park Water Plant. Quantity of six (6)

FLOWSERVE

Ser: 2203NNH00203-1 thru 2203NNH00203-6 Type: Vert Model: VPC-20EKH-1 Size: 15’’

RPM: 1790

GPM: 4800

HP: 150

# of Stages: 4

File details come from the government source that posted it. Updated .