The document is a detailed technical drawing titled "6 Foot Chain Link Fence Detail" from a Stantec engineering project, specifically Attachment B from a set of site detail drawings. The drawing provides a comprehensive cross-section and elevation view of a 6-foot chain link fence installation, including precise measurements and component specifications. Key details include:
- Fence height of 6 feet with vertical posts to be positioned at corners and gates
- Vertical barbed wire line post arm at the top of the fence
- Multiple horizontal rails (top rail, line rail, and brace rail) with specific tie and attachment specifications
- 9ga galvanized tension wire at the bottom of the fence
- 3" corner posts and 2-1/8" line posts
- Concrete foundation with 36-inch deep footings
- Detailed mounting and connection methods using truss rods, ties, and Simpson adapters
The technical drawing includes precise dimensional annotations, material specifications (such as galvanized components), and installation guidelines for constructing a standard chain link fence. The drawing is part of a larger set of site details that include variations like cedar fence sections and gate details, suggesting this is part of a comprehensive site infrastructure or facility development project.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3-26-048-B Attachment C Zone Map.pdf | ||
| 1-26-048-B Bid Pricing Form 2025-10-30.xlsx | XLSX spreadsheet | |
| 2-26-048-B Solicitation Packet 2025-10-30.docx.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment B
6 Foot Chain Link Fence Detail:
FLAG POLE DETAIL
PLAN VIEW
ELEVATION
GATE STOP DETAIL
TYPICAL ELEVATION OF GATE/SCREEN WALL
2'-0" DIA
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
Copyright Reserved
ORIGINAL SHEET - ARCH E1
Revision By Appd YYYY.MM.DD
Issued By Appd YYYY.MM.DD
Drawing No.Revision
Project No.
Title
Scale
Client/Project
Client/Project Logo
Permit/Seal
Consultant
Notes
ATS AH
/8
/2
: 3 :5
P
M
As indicated
P ic k lo c a ti o n in P ro je c t
In fo rm a ti o n
Stantec Architecture Inc.
6080 Tennyson Parkway Suite 200
Plano, 75024-6003
Tel: (214) 473-2400 • www.stantec.com
401 E. BROWN STREET
WYLIE, TX 75098
SITE DETAILS
214000865
ISSUED FOR BID, PERMIT, CONSTRUCTION
AS005
NTMWD
MULTIPLE SYSTEMS MAINTENANCE FACILITIES
CENTRAL REGION, PHASE II
2021.09.07
C4 DECORATIVE GATE DETAILS
C3 DECORATIVE FENCE DETAILS
A5 FLAG POLE DETAIL
A3 GATE STOP DETAIL
A1 AS51_SITE_GATE_SWING
C2 SPLASH BLOCK DETAIL
2 ADDENDUM #2 ATS AH 2021.09.29
5 ADDENDUM #5 ATS AH 2021.10.31
D1 CHAINLINK FENCE & GATE DETAILS
D5 MOW STRIP DETAIL
C1 PIPE BOLLARD DETAIL
cmetz Line cmetz Line cmetz Line cmetz Line
| 25-197-B Attachment B |
| 20-086-B Fence Map.pdf |
| Gates H Brace |
| L. Gate and Stretch Post Cut Sheet |
| L. Fence Detail Specs |
| L. 6 Ft Wood |
| L. 8 ft Wood |
| L. Chain Link 2 |
| Attachment B |
| Pages from MSMFCR_Phase_II-Conformed_Const_Set (3) |
File details come from the government source that posted it. Updated .