The documents are architectural and life safety plans for the Collier County Public Utilities Raw Water Booster Pump Station Improvements project in Naples, Florida. The project includes multiple building improvements: an existing pump building, a parking canopy, and associated architectural modifications. The plans detail life safety requirements, building code analyses, floor plans, demolition notes, and accessibility features, prepared by Tetra Tech for Collier County. The buildings are classified as utility (U) and storage (S-1) occupancy types, with non-sprinklered construction under the 2023 Florida Building Code.

The project involves three primary structures: an existing pump building with rooms including a pump room, electric room, generator room, and unisex toilet; a parking canopy with three bays (one enclosed, two open); and associated architectural renovations. The buildings are designed as non-combustible, Type IIB construction with no fire resistance ratings for structural elements. The occupancy is designed as unoccupied, with no full-time occupants expected. The plans include detailed life safety elements such as fire extinguisher locations, exit routes, travel distances, and compliance with Florida Building Code requirements for egress, accessibility, and emergency lighting.

View the file

Other files

File Type Posted
100%_Specifications_10-13-25_.pdf PDF
Image_1.JPG JPG image
Image_1.JPG JPG image
Image_2.JPG JPG image
Image_2.JPG JPG image
100%_Specs_9-25-25.pdf PDF
3A_-_Architectural_Plans_(A-001)_-_100%_-_9-25-25.pdf PDF
3A_-_Architectural_Plans_(A-001)_-_100%_-_9-25-25.pdf PDF
25-8400_-_Solicitation_R1.pdf PDF
25-8400_-_Solicitation_R1.pdf PDF
25-8400_-_Solicitation_R1.pdf PDF
25-8400_-_Solicitation_R1.pdf PDF
25-8400_-_Solicitation_R1.pdf PDF
Construction_Bid_Instructions_Version_1.pdf PDF
Construction_Bid_Instructions_Version_1.pdf PDF
Construction_Bid_Instructions_Version_1.pdf PDF
25-8400_-_Authorization_to_Advertise.pdf PDF
25-8400_-_Authorization_to_Advertise.pdf PDF
25-8400_-_Authorization_to_Advertise.pdf PDF
Construction_Services_Agreement_2025_ver._3.pdf PDF
1_-_General_and_Civil_Plans_-_100%_-_4-11-25_.pdf PDF
6_-_Electrical_-_100%_-_4-15-25_.pdf PDF
Construction_Services_Agreement_2025_ver._3.pdf PDF
1_-_General_and_Civil_Plans_-_100%_-_4-11-25_.pdf PDF
25-8400_Bid_Schedule.pdf PDF
4_-_Plumbing_Plans_-_100%_-_4-9-25_.pdf PDF
5_-_Mechanical_-_100%_-_4-9-25_.pdf PDF
1_-_General_and_Civil_Plans_-_100%_-_4-11-25_.pdf PDF
25-8400_Bid_Schedule.pdf PDF
3B_-_Architectural_Plans_(A-101_to_A-104)_-_100%_-_4-9-25_.pdf PDF
6_-_Electrical_-_100%_-_4-15-25_.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
25-8400_Bid_Schedule.pdf PDF
3B_-_Architectural_Plans_(A-101_to_A-104)_-_100%_-_4-9-25_.pdf PDF
6_-_Electrical_-_100%_-_4-15-25_.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
2_-_Structural_Plans_-_100%_-_4-9-25_.pdf PDF
4_-_Plumbing_Plans_-_100%_-_4-9-25_.pdf PDF
2_-_Structural_Plans_-_100%_-_4-9-25_.pdf PDF
6_-_Electrical_-_100%_-_4-15-25_.pdf PDF
Construction_Services_Agreement_2025_ver._3.pdf PDF
4_-_Plumbing_Plans_-_100%_-_4-9-25_.pdf PDF
5_-_Mechanical_-_100%_-_4-9-25_.pdf PDF
5_-_Mechanical_-_100%_-_4-9-25_.pdf PDF
2_-_Structural_Plans_-_100%_-_4-9-25_.pdf PDF
4_-_Plumbing_Plans_-_100%_-_4-9-25_.pdf PDF
Construction_Services_Agreement_2025_ver._3.pdf PDF
1_-_General_and_Civil_Plans_-_100%_-_4-11-25_.pdf PDF
25-8400_Bid_Schedule.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T.D. = XX' TRAVEL DISTANCE = __ FEET

PATH OF TRAVEL SYMBOL

BRACKET MOUNTED FIRE

EXTINGUISHER

EXIT

EGRESS EXIT

EXIT

EGRESS DOORWAY

LIFE SAFETY LEGEND

EXITING WIDTH PROVIDED

EXITING WIDTH REQUIRED

0" 0"

FE

PUMP ROOM

CORRIDOR

OFFICE

ELECTRIC ROOM

UNISEX TOILET

OFFICE

GENERATOR

ROOM

FUEL TANK

T .D

32" 36"

EXIT

32" 36"

EXIT

32" 36"

EXIT

32" 36"

EXIT

T.D. = 33'-0"

T .D

T .D

FE FE

FE

FE

T.D. = 25'-0"

32" 36"

EXIT

T .D

T.D. = 10'-0"

32" 36"

EXIT

T .D

T.D. = 17'-0"

32" 36"

EXIT

32" 36"

EXIT

N.I.C.

N.I.C.

N.I.C. N.I.C.OFFICE

TOILET

N

CHKD:

DRWN:

PROJ:

DESN:

w w w .t e tr a te c h

.c o m

A

B

C

D

E

F

2 3 4 5 6 7

Bar measures 1 inch, otherwise drawing is not to scale

C o p y ri g h t:

T e tr a T e c h

0' 8' 16'8'

SCALE: 1/8" = 1'-0"

/7

/2

:3

:5

P M

A u to d e s k D o c s /2

-0

-2

C o lli e r

C o

B ri d g e

C ra n e A d d /A

-2

C

C B

C A

R

W B

.r v t

200-08486-24001

S. AMIRI

T. MOURAD

S. VICE

A-101

C O

L L

IE

R C

O U

N T

Y P

U B

L

IC

U T

IL

IT

IE

S

R A

W W

A T

E R

B O

O S

T E

R P

U M

P S

T A

T

IO

N

IM

P R

O V

E M

E N

T S

E X

IS

T

IN

G

P U

M P

B U

IL

D

IN

G

A R

C H

IT

E

C T

U R

A L

L

IF

E S

A F

E T

Y P

L A

N

E N

G

IN

E E

R

IN

G B

U S

IN

E

S S

N O x x x x

C

H E

V R

O L

E T

W A

Y

S U

IT

E

E

S T

E R

O

F L

100% SUBMITTAL

P H

(2

-1

SCALE: 1/8" = 1'-0"

LIFE SAFETY FIRST FLOOR PLAN

FLORIDA BUILDING CODE ANALYSIS

BUILDING DESCRIPTION

BUILDING LOCATION

841 7TH STREET SW NAPLES, FLORIDA 34110

FIRE PROTECTION

SPRINKLERS: NON-SPRINKLERED

FIRE EXTINGUISHERS: PROVIDED

EXIT LIGHTING PROVIDED

USE GROUP (FBC CHAPTER 3)

OCCUPANCY USE (FBC 311.2) U UTILITY AND MISCELLANEOUS

OCCUPANCY GROUP(U) (FBC TABLE 508.4) U

DESIGN OCCUPANCY UNOCCUPIED - NO FULL-TIME

OCCUPANTS

GENERAL BUILDING HEIGHTS AND AREAS (FBC CHAPTER 5)

TYPE OF CONSTRUCTION (FBC TABLE 601) IIB, NON-COMBUSTIBLE,

NON-SPRINKLERED

ALLOWABLE HEIGHT (FBC TABLE 504.3) 75 FEET

STORIES PERMITTED (FBC TABLE 504.4) 2 STORIES

AREA PERMITTED (FBC TABLE 506.2) 8,500 SF

FIRE-RESISTANCE RATING FOR BUILDING ELEMENTS

PRIMARY STRUCTURAL FRAMES 0 HR

BEARING WALLS - EXTERIOR 0 HR

BEARING WALLS - INTERIOR 0 HR

NON-BEARING WALLS AND PARTITIONS - INTERIOR 0 HR

FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY 0 HR

ROOF CONSTRUCTION AND ASSOCIATED SECONDARY 0 HR

FIRE SEPARATION DISTANCE X>/=30'-0"

FIRE AND SMOKE PROTECTION FEATURES (FBC CHAPTER 7)

NO FIRE/SMOKE ALARM SYSTEM IS REQUIRED - THE AREA OF THE BUILDING IS UNDER

12,000 SF

MEANS OF EGRESS (FBC CHAPTER 10)

EGRESS COMPONENT SIZING (FBC 1005.1) = OCC. X 0.2 INCHES = 2 INCHES

CONTINUITY (FBC 1005.4) COMPLIES

DISTRIBUTION (FBC 1005.5) COMPLIES

ILLUMINATION REQUIRED (FBC 1008.1) COMPLIES

ILLUMINATION LEVEL (FBC1008.2) COMPLIES

EMERGENCY POWER (FBC 1008.3) COMPLIES

ILLUMINATION UNDER EMERGENCY POWER (FBC 1008.3.1) COMPLIES

EXIT AND EXIT ACESS DOORWAYS (FBC 1006)

SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY [FBC TABLE 1006.3.2 (2)]:

USE GROUP MAXIMUM LOAD = 16 OCC.

NUMBER OF EXITS REQUIRED = 6

NUMBER OF EXITS PROVIDED = 9

CORRIDOR FIRE RESISTANCE RATING N/A

PLUMBING FIXTURES

DRINKING FOUNTAINS OWNER PROVIDED

WATER CLOSET 2 REQUIRED - 2PROVIDED

LAVATORY 2 REQUIRED - 2 PROVIDED

UTILITY SINK 1 PROVIDED

URINAL N/A

APPLICABLE FLORIDA BUILDING CODES

2023 FLORIDA BUILDING CODE: BUILDING

2023 FLORIDA BUILDING CODE: MECHANICAL

2023 FLORIDA BUILDING CODE: PLUMBING

2023 FLORIDA FIRE PREVENTION CODE

2023 NFPA 101 LIFE SAFETY CODE

2023 FLORIDA BUILDING CODE: ACCESSIBILITY

2023 FLORIDA BUILDING CODE: ENERGY CONSERVATION

NFPA 70 (2014) NATIONAL ELECTRICAL CODE

NFPA 10 (2018) STANDARD FOR PORTABLE FIRE EXTINGUISHERS

BULDING SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE 2017

FLORIDA BUILDING CODE (FBC) AND LOCAL CODE ORDINANCES

OCCUPANCY SCHEDULE

ROOM NO ROOM NAME AREA

OCC.

CLASS OCC. LOAD

14 FUEL TANK 240 SF U = 0

101 CORRIDOR 74 SF U = 0

102 ELECTRIC ROOM 768 SF U = 0

103 UNISEX TOILET 150 SF U = 0

104 PUMP ROOM 2044 SF U = 0

105 GENERATOR ROOM 578 SF U = 0

106 OFFICE 402 SF B = 0

TOTAL: 4256 SF 0

SCALE: NTS

KEY PLAN

N/A

N/A

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N B

Y

UNISEX TOILET

CORRIDOR

OFFICE

A-102

T-7

T-6

T-3

T-5

T-4

T-1

T-2

T-3

T-1

T-2

S-1

A-102

T-9

CORRIDOR

TOILET

OFFICE

D1

D3D2

D4

N.I.C.

N.I.C.

N.I.C. N.I.C.OFFICE

TOILET

LEVEL 1

100' - 0"

LEVEL 2

110' - 0"

T-6

T-7T-2

UNISEX TOILET

T-9

LEVEL 1

100' - 0"

LEVEL 2

110' - 0"

/4

1' - 11"

T-1

T-4

T-2

T-3

T-5 T-1

T-3

T-2

UNISEX TOILET

T-9

2"

2"

V E

R

IF

Y I N

F E

IL

D

EXISTING CONCRETE FLOOR

EXISTING

CONCRETE FLOOR

#5 REBAR DOWELS AT 12" O.C.

EACH WAY - EPOXY INTO

EXISITING CONCRETE

MAX

11"

M A

X

F R

O M

N O

S

IN

G

1' - 0"

11"

1 1/4" STD. PIPE RAIL - PAINT

STEEL RAILING SPPORTS

(EXP. BOLT TO WALL)

#5 REBAR (TYP)

3500 P.S.I. CONCRETE STAIRS

1" TYP

WALL MOUNTED

SIGNAGE - SEE

NOTES

CENTERLINE OF

SIGN (TYPICAL

ALL SIGN TYPES)

DOUBLE EMULSION

FOAM TAPE

SIGNAGE PER PLANS,

SCHEDULE AND

SPECIFICATIONS

DRYWALL PARTITION

ROOM

5 125/128"

ALIGN PICTOGRAM, TEXT,

BRAILLE TO CENTER LINE

UNISEX

/8

1' - 0"

/8

" 1

/2

" 1

/2

/2

S-1

EQ. EQ.

RESTROOM

/8

/2

UNISEX RESTROOM

R 1"

1 MEDECO CYLINDER MEDECO CYLINDER

1 PUSH PLATE 8200 8 X 16 US32D

1 PULL PLATE 8305-8 4 X 16 TYPE F MTG. US32D

1 CLOSER SC71A RW/PA 689

1 WALL STOP WS406/407CVX US32D

3 DOOR SILENCER SR64 GRY

NOTE: REGULAR ARM MOUNTED DOOR CLOSER - INSTALL DOOR CLOSER ON PULL SIDE OF THE DOOR.

DOOR 103 HARDWARE SET

N

CHKD:

DRWN:

PROJ:

DESN:

w w w .t e tr a te c h

.c o m

A

B

C

D

E

F

2 3 4 5 6 7

Bar measures 1 inch, otherwise drawing is not to scale

C o p y ri g h t:

T e tr a T e c h

0' 4' 8'4'

SCALE: 1/4" = 1'-0"SCALE: 3/4" = 1'-0"

0' 1' 2' 3'1'0' 2' 4'2'

SCALE: 1/2" = 1'-0"

/7

/2

:3

:0

P M

A u to d e s k D o c s /2

-0

-2

C o lli e r

C o

B ri d g e

C ra n e A d d /A

-2

C

C B

C A

R

W B

.r v t

200-08486-24001

S. AMIRI

T. MOURAD

S. VICE

A-102

C O

L L

IE

R C

O U

N T

Y P

U B

L

IC

U T

IL

IT

IE

S

R A

W W

A T

E R

B O

O S

T E

R P

U M

P S

T A

T

IO

N

IM

P R

O V

E M

E N

T S

E X

IS

T

IN

G

P U

M P

B U

IL

D

IN

G

A R

C H

IT

E

C T

U R

A L

F L

O O

R P

L A

N S

A N

D E

L E

V A

T

IO

N S

E N

G

IN

E E

R

IN

G B

U S

IN

E

S S

N O x x x x

C

H E

V R

O L

E T

W A

Y

S U

IT

E

E

S T

E R

O

F L

100% SUBMITTAL

P H

(2

-1

SCALE: 1/4" = 1'-0"

ARCHITECTURAL FIRST FLOOR PLAN

SCALE: 1/4" = 1'-0"

ARCHITECTURAL FIRST FLOOR PLAN

DEMOLITION

GENERAL NOTES - DEMOLITION

A ALL AREAS DESIGNATED BY DASHED LINES ARE TO BE REMOVED.

B ALL AREAS AND PARTITIONS NOT DASHED OR NOTED TO BE REMOVED SHALL

REMAIN INTACT. PATCH AND REPAIR EXISTING ADJACENT SURFACES AS

REQUIRED AFTER DEMOLITION TO MATCH EXISTING OR IN ACCORDANCE WITH

PROPOSED RENOVATIONS.

C PROVIDE INTERIOR AND EXTERIOR SHORING, BRACING, OR OTHER SUPPORT TO

PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF ELEMENTS TO BE

DEMOLISHED AND ADJACENT EXISTING ELEMENTS TO REMAIN.

D LOCATE AND IDENTIFY EXISTING UTILITIES, INCLUDING SANITARY SEWER SYSTEM,

AND ASCERTAIN THEIR CONDITION TO ENSURE ADEQUATE PERFORMANCE OF ALL

UTILITIES IN NEW CONSTRUCTION. PROTECT UTILITY LINES AND HARDWARE

DURING DEMOLITION AND CONSTRUCTION PHASES.

E ALL HAZARDOUS MATERIALS WILL BE ADDRESSED BY OWNER. IF HAZARDOUS

MATERIALS ARE ENCOUNTERED DURING DEMOLITION OPERATIONS IT SHALL BE

BROUGHT TO OWNER ATTENTION.

F SEE M/P/E DRAWINGS FOR COORDINATION AND FURTHER INFORMATION ON

MECHANICAL, PLUMBING AND ELECTRICAL DEMOLITION. INCLUDING BUT NOT

LIMITED TO EXISTING PLUMBING FIXTURES, DRAINAGE AND VENT PIPING, AND

SURFACE MOUNTED CONDUIT AND WIREMOLD. REMOVE OR RELOCATE INTERIOR

SURFACE MOUNTED ITEMS WHERE THEY CONFLICT WITH NEW WORK.

G COORDINATE ALL DEMOLITION WITH OWNER AND OTHER TRADES.

H IN ALL AREAS OF CONSTRUCTION REMOVE ALL EXISTING WALL MOUNTED ITEMS

INCLUDING BUT NOT LIMITED TO TACKBOARDS, PHOTOGRAPHS, FRAMED ITEMS,

SIGNAGE, SAFETY EQUIPMENT AND ALL ASSOCIATED HANGERS AND SUPPORTS.

TURN OVER, CAREFULLY STORE FOR RE-USE/REINSTALLATION OR DISPOSE OF AS

DIRECTED BY OWNER.

I VERIFY DIMENSIONS AND LOCATIONS. IT IS ANTICIPATED THAT EXISTING

CONDITIONS SHALL REQUIRE SLIGHT ADJUSTMENTS.

J PATCH AND REPAIR WALLS AT ALL REMOVED WALL MOUNTED EQUIPMENT,

INCLUDING FIRE EXTINGUISHER CABINETS, SIGNAGE, HOOKS AND HANGERS AND

ALL OTHER MISCELLANEOUS ITEMS, TO MATCH ADJACENT WALL SURFACES

K PROVIDE TEMPORARY SUPPORT AND REATTACHMENT FOR CEILING MOUNTED

FIXTURES AND EQUIPMENT NOT SCHEDULED FOR REMOVAL.

L IN AREAS OF CEILING DEMOLITION, REMOVE EXISTING CEILING HUNG ITEMS,

INCLUDING BUT NOT LIMITED TO: PROJECTOR SCREENS AND TELEVISIONS. REFER

TO MEP FOR ADDITIONAL REMOVAL INFORMATION

KEYNOTE

D1 REMOVE CONCRETE SLAB

D2 REMOVE SINK AND CAP ALL PLUMBING

D3 REMOVE TOILET AND CAP ALL PLUMBING

D4 REMOVE EXISTING HARDWARE FROM DOOR

SCALE: NTS

KEY PLAN

SCALE: 1/4" = 1'-0"A-102

RESTROOM ELEVATION -

SOUTH

SCALE: 1/4" = 1'-0"A-102

1 RESTROOM ELEVATION - EAST

RESTROOM ACCESSORIES SCHEDULE

MARK DESCRIPTION COMMENTS

T-1 GRAB BAR TYPE 4 (GB) 18", MOUNTED TO ADA STANDARDS

T-2 36" GRAB BAR All grab bar configurations are specified using centerline to centerline dimensions.

T-3 42" GRAB BAR All grab bar configurations are specified using centerline to centerline dimensions.

T-4 SEAT COVER

DISPENSER

T-5 Multi-Roll Toilet Tissue Dispenser, Reserve Roll

T-6 MIRROR FRAMELESS (20" W X 40" H)

T-7 SOAP DISPENSER

T-9 SHOWER ROD AND

CURTAIN

SS ROD - FIT TO SHOWER OPENING

SCALE: 3/4" = 1'-0"A-102

4 SECTION THROUGH STAIR

SIGNAGE SCHEDULE

MARK SIGN TYPE COMMENTS

S-1 UNISEX RESTROOM DOUBLE-BACKED TAPE MOUNT

SCALE: 1/2" = 1'-0"A-102

5 MOUNTING DETAILS

SCALE: 6" = 1'-0"A-102

3 RESTROOM SIGN S-1

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N B

Y

0 1" 2" 4"

SCALE: 6" = 1'-0"

T.D. = XX' TRAVEL DISTANCE = _200_ FEET

PATH OF TRAVEL SYMBOL

BRACKET MOUNTED FIRE

EXTINGUISHER

EXIT

EGRESS EXIT

EXIT

EGRESS DOORWAY

LIFE SAFETY LEGEND

EXITING WIDTH PROVIDED

EXITING WIDTH REQUIRED

0" 0"

FE

T.D. = 35'-0"

T.D. = 33'-0"

FE

FE

D

C

B

A

1 2 3 4

32" 36"

EXIT

32" 36"

EXIT

BAY 1 ENCLOSED

BAY 2 OPEN

BAY 3 OPEN

N

CHKD:

DRWN:

PROJ:

DESN:

w w w .t e tr a te c h

.c o m

A

B

C

D

E

F

2 3 4 5 6 7

Bar measures 1 inch, otherwise drawing is not to scale

C o p y ri g h t:

T e tr a T e c h

0' 8' 16'8'

SCALE: 1/8" = 1'-0"

/9

/2

:1

:5

P M

A u to d e s k D o c s /2

-0

-2

C o lli e r

C o B ri d g e C ra n e

A d d

/A

-2

C

C B

C A

E n c lo s e d G a ra g e .r v t

200-08486-24001

Designer

Author

Checker

A-103

C O

L L

IE

R C

O U

N T

Y P

U B

L

IC

U T

IL

IT

IE

S

R A

W W

A T

E R

B O

O S

T E

R P

U M

P S

T A

T

IO

N P

A R

K

IN

G C

A N

O P

Y

A R

C H

IT

E

C T

U R

A L

L

IF

E S

A F

E T

Y P

L A

N E

N G

IN

E

E R

IN

G

B U

S

IN

E S

S N

O x x x x

C H

E V

R O

L E

T W

A Y

S

U

IT

E

E S

T E

R O

F

L

100% SUBMITTAL

P H

(2

-1

7APPLICABLE FLORIDA BUILDING CODES

2023 FLORIDA BUILDING CODE: BUILDING

2023 FLORIDA BUILDING CODE: MECHANICAL

2023 FLORIDA BUILDING CODE: PLUMBING

2023 FLORIDA FIRE PREVENTION CODE

2023 NFPA 101 LIFE SAFETY CODE

2023 FLORIDA BUILDING CODE: ACCESSIBILITY

2023 FLORIDA BUILDING CODE: ENERGY CONSERVATION

NFPA 70 (2014) NATIONAL ELECTRICAL CODE

NFPA 10 (2018) STANDARD FOR PORTABLE FIRE EXTINGUISHERS

BULDING SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE 2017

FLORIDA BUILDING CODE (FBC) AND LOCAL CODE ORDINANCES

SCALE: 1/8" = 1'-0"

LIFE SAFETY FIRST FLOOR PLAN

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N B

Y

FLORIDA BUILDING CODE ANALYSIS

BUILDING DESCRIPTION

STORAGE BAY WITH 2 OPEN BAYS UNDER ROOF

BUILDING LOCATION

1500 MONROE ST, FORT MYERS, FLORIDA 33901

FIRE PROTECTION

SPRINKLERS: NON-SPRINKLERED

FIRE EXTINGUISHERS: PROVIDED

EXIT LIGHTING PROVIDED

USE GROUP (FBC CHAPTER 3)

OCCUPANCY USE (FBC 311.2) S-1 MODERATE HAZARD

STORAGE

OCCUPANCY GROUP(S) (FBC TABLE 508.4) S-1

DESIGN OCCUPANCY UNOCCUPIED - NO FULL-TIME

OCCUPANTS

GENERAL BUILDING HEIGHTS AND AREAS (FBC CHAPTER 5)

TYPE OF CONSTRUCTION (FBC TABLE 601) IIB, NON-COMBUSTIBLE,

NON-SPRINKLERED

ALLOWABLE HEIGHT (FBC TABLE 504.3) 55 FEET

STORIES PERMITTED (FBC TABLE 504.4) 3 STORIES

AREA PERMITTED (FBC TABLE 506.2) 17,500 SF

FIRE-RESISTANCE RATING FOR BUILDING ELEMENTS

PRIMARY STRUCTURAL FRAMES 0 HR

BEARING WALLS - EXTERIOR 0 HR

BEARING WALLS - INTERIOR 0 HR

NON-BEARING WALLS AND PARTITIONS - INTERIOR 0 HR

FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY 0 HR

ROOF CONSTRUCTION AND ASSOCIATED SECONDARY 0 HR

FIRE SEPARATION DISTANCE X>/=30'-0"

FIRE AND SMOKE PROTECTION FEATURES (FBC CHAPTER 7)

NO FIRE/SMOKE ALARM SYSTEM IS REQUIRED - THE AREA OF THE BUILDING IS UNDER

12,000 SF

MEANS OF EGRESS (FBC CHAPTER 10)

EGRESS COMPONENT SIZING (FBC 1005.1) = OCC. X 0.2 INCHES = 2 INCHES

CONTINUITY (FBC 1005.4) COMPLIES

DISTRIBUTION (FBC 1005.5) COMPLIES

ILLUMINATION REQUIRED (FBC 1008.1) COMPLIES

ILLUMINATION LEVEL (FBC1008.2) COMPLIES

EMERGENCY POWER (FBC 1008.3) COMPLIES

ILLUMINATION UNDER EMERGENCY POWER (FBC 1008.3.1) COMPLIES

EXIT AND EXIT ACESS DOORWAYS (FBC 1006)

SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY [FBC TABLE 1006.3.2 (2)]:

USE GROUP MAXIMUM LOAD = 1 OCCUPANT PER 500 SQUARE FEET 4 OCC.

NUMBER OF EXITS REQUIRED = 2

NUMBER OF EXITS PROVIDED = 2

CORRIDOR FIRE RESISTANCE RATING N/A

PLUMBING FIXTURES

DRINKING FOUNTAINS N/A

WATER CLOSET N/A

LAVATORY N/A

UTILITY SINK N/A

URINAL N/A

OCCUPANCY SCHEDULE

ROOM NO ROOM NAME AREA

OCC.

CLASS OCC. LOAD

101 BAY 1 ENCLOSED 1662 SF S-1 = 1/0 0

102 BAY 2 OPEN 1537 SF 0

103 BAY 3 OPEN 1484 SF 0

TOTAL: 4684 SF 01662 SF

1662 SF

N/A

N/A

D

C

B

A

1 2 3 4

/8

/8

/8

1' - 4" 25' - 8" 27' - 11" 25' - 8"

1' - 4"

79' - 3"

28' - 4"

1B

1A

8' - 2" 12' - 0" 8' - 2"

81' - 11"

BAY 1 ENCLOSED

BAY 2 OPEN

BAY 3 OPEN

N

CHKD:

DRWN:

PROJ:

DESN:

w w w .t e tr a te c h

.c o m

A

B

C

D

E

F

2 3 4 5 6 7

Bar measures 1 inch, otherwise drawing is not to scale

C o p y ri g h t:

T e tr a T e c h

SCALE: 3/16" = 1'-0"

0' 4' 8' 12'4'

/9

/2

:1

:5

P M

A u to d e s k D o c s /2

-0

-2

C o lli e r

C o B ri d g e C ra n e

A d d

/A

-2

C

C B

C A

E n c lo s e d G a ra g e .r v t

200-08486-24001

Designer

Author

Checker

A-104

C O

L L

IE

R C

O U

N T

Y P

U B

L

IC

U T

IL

IT

IE

S

R A

W W

A T

E R

B O

O S

T E

R P

U M

P S

T A

T

IO

N P

A R

K

IN

G C

A N

O P

Y

A R

C H

IT

E

C T

U R

A L

F L

O O

R P

L A

N E

N G

IN

E

E R

IN

G

B U

S

IN

E S

S N

O x x x x

C H

E V

R O

L E

T W

A Y

S

U

IT

E

E S

T E

R O

F

L

100% SUBMITTAL

P H

(2

-1

7GENERAL NOTES - FLOOR PLAN

1. REFER TO SHEET S-105 FOR DOOR TYPES, DOOR FRAMES, AND DOOR

SCHEDULE.

SCALE: 3/16" = 1'-0"

ARCHITECTURAL FIRST FLOOR PLAN

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N B

Y

Sheets
A-101 - ARCHITECTURAL LIFE SAFETY PLAN
A-102 - ARCHITECTURAL FLOOR PLANS AND ELEVATIONS
2025-04-09T15:48:47-0400
James Q Biagi

File details come from the government source that posted it. Updated .