1_-_General_and_Civil_Plans_-_100%_-_4-11-25_.pdf
PDF 22 MB Posted
- Attached to
- Raw Water Booster Pump Station Improvements
- Solicitation number
- 25-8400
- Issued by
- Collier County, Florida
About this file
This is a 100% submittal of engineering design plans and specifications for the Raw Water Booster Pump Station Improvements project prepared by Tetra Tech for Collier County Public Utilities in Naples, Florida. The project encompasses five major components: flow meter replacement, office space and restroom upgrades, construction of a pre-engineered metal building (PEMB) parking canopy, installation of a potable well and reverse osmosis (RO) water treatment system, and inspection and cleaning of the existing wastewater subsurface disposal system. The design documents include comprehensive civil, structural, architectural, plumbing, mechanical, and electrical plans across 34 sheets detailing site layouts, demolition requirements, pipe routing, foundation designs, electrical single-line diagrams, and mechanical controls. The plans establish a 90-foot radius construction boundary and specify general notes requiring contractors to verify utility locations 48 hours in advance, coordinate with county utilities and emergency services, manage turbidity barriers, maintain access to facilities, and comply with Collier County standards and Florida Administrative Code requirements. Work hours are restricted to 7:00 a.m. to 7:00 p.m. Monday through Friday, with Saturday work requiring 48-hour written notice and approval.
The project documents establish specific operational constraints for the Raw Water Booster Pump Station shutdown timing, with allowable shutdowns varying by season: eight hours January through May, 24 hours June through September, and 12 hours October through December. Contractors must provide their own restroom facilities and are responsible for site investigation regarding rock depth, organic silt peat areas, dewatering requirements, and off-site fill material sourcing, with no additional compensation provided for inadequate pre-bid investigation. The potable water system requires turnkey installation including a four-inch well with one horsepower, 20-gallon-per-minute pump, one-inch HDPE water main, backflow preventer, hydro-pneumatic tank, reverse osmosis treatment system, building interior connections, disinfection, water testing, electrical connections, drilling slurry cleanup, startup and testing, and a three-year warranty on all parts and labor. All proposed improvements must follow Collier County standards, and contractors are liable for immediate repair of any damage to county mains and facilities at their expense.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N
10600 Chevrolet Way, Suite 102
Estero, Florida 33928
Engineering Business No. 2429
DATE ______________
PREPARED FOR
COLLIER COUNTY PUBLIC UTILITIES
BOARD OF COUNTY COMMISSIONERS
RICK LOCASTRO DISTRICT 1
CHRIS HALL DISTRICT 2
BURT L. SAUNDERS DISTRICT 3 (CHAIRMAN)
DAN KOWAL DISTRICT 4 (VICE CHAIRMAN)
WILLIAM L. MCDANIEL, JR. DISTRICT 5
COLLIER COUNTY WATER-SEWER DISTRICT
3339 TAMIAMI TRAIL E., SUITE 303
NAPLES, FLORIDA 34112
COLLIER COUNTY
PROJECT SITE
SCALE: N.T.S.
www.tetratech.com
CLIENT INFORMATION:PROJECT LOCATION:
PROJECT DESCRIPTION / NOTES:
Tt PROJECT No.: CLIENT PROJECT No.:
ISSUED:
COLLIER COUNTY PUBLIC UTILITIES
RAW WATER BOOSTER PUMP STATION
IMPROVEMENTS
841 7TH ST SW
NAPLES, FL 34117
COLLIER COUNTY PUBLIC UTILITIES
3339 TAMIAMI TRAIL EAST, SUITE 303
NAPLES, FL 34112
10600 CHEVROLET WAY, SUITE 102
ESTERO, FL 33928
PH: (239) 390-1467
VICINITY MAP:
N
PROJECT LOCATION
PROJECT LOCATION WITHIN
THIS PROPERTY BOUNDARY
T
H
S
T
S
W
1. FLOW METER REPLACEMENT
2. OFFICE SPACE AND RESTROOM UPGRADES
3. PRE-ENGINEERED METAL BUILDING (PEMB) FOR PARKING CANOPY
4. POTABLE WELL AND REVERSE OSMOSIS (RO) SYSTEM
5. WASTEWATER SUBSURFACE DISPOSAL SYSTEM INSPECTION AND CLEANING.
04/11/25 - 100% SUBMITTAL
200-08486-24001 70085.30.1
T
H
S
T
S
W
SHEET NO. SHEET TITLE
GENERAL
G-000 COVER SHEET
G-001
LOCATION MAP, GENERAL NOTES, AND DRAWING INDEX
G-002 LEGENDS AND ABBREVIATIONS
CIVIL
C-101 GENERAL SITE PLAN
C-102 EXISTING YARD PIPING PLAN
C-103 EXISTING FLOW METER PIPING AND DEMOLITION PLAN & SECTION
C-104 PROPOSED FLOW METER PIPING PLAN & SECTION
C-501 CIVIL DETAILS
C-502 CIVIL DETAILS
STRUCTURAL
S-101 PARKING CANOPY STRUCTURAL NOTES & DESIGN CRITERIA
S-102 PARKING CANOPY STRUCTURAL NOTES & ABBREVIATIONS
S-103 PARKING CANOPY FOUNDATION AND ROOF PLANS
S-104 PARKING CANOPY PEMB FRAME ELEVATION
S-105 PARKING CANOPY FOUNDATION SECTIONS AND DETAILS
S-106 PARKING CANOPY ROOF SECTIONS AND DETAILS
S-107 PARKING CANOPY ELEVATIONS
ARCHITECTURAL
A-001 EXISTING PUMP BUILDING
A-101 EXISTING PUMP BUILDING ARCHITECTURAL LIFE SAFETY PLAN
A-102 EXISTING PUMP BUILDING ARCHITECTURAL FLOOR PLANS AND ELEVATIONS
A-103 PARKING CANOPY ARCHITECTURAL LIFE SAFETY PLAN
A-104 PARKING CANOPY ARCHITECTURAL FLOOR PLAN
PLUMBING
P-001
PLUMBING ABBREVIATIONS, LEGEND, & NOTES
P-101 EXISTING PUMP BUILDING PLUMBING DEMOLITION PLAN
P-201 EXISTING PUMP BUILDING PLUMBING PRESSURE & SANITARY PIPING PLAN
P-501 EXISTING PUMP BUILDING PLUMBING DETAILS
P-601 EXISTING PUMP BUILDING PLUMBING SCHEDULES & RISER DIAGRAMS
MECHANICAL
M-001
MECHANICAL ABBREVIATIONS, LEGENDS, AND NOTES
M-002 MECHANICAL GENERAL NOTES
M-101 EXISTING PUMP BUILDING MECHANICAL DEMOLITION PLAN & SECTIONS
M-201 EXISTING PUMP BUILDING MECHANICAL ZONING PLAN
M-202 EXISTING PUMP BUILDING MECHANICAL MODIFICATION PLAN
M-203 PARKING CANOPY MECHANICAL PLAN
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-601 EXISTING PUMP BUILDING MECHANICAL SCHEDULES
M-602 PARKING CANOPY MECHANICAL SCHEDULES
M-901 EXISTING PUMP BUILDING MECHANICAL CONTROLS
M-902 PARKING CANOPY MECHANICAL CONTROLS
ELECTRICAL
E-001 ELECTRICAL LEGEND AND ABBREVIATIONS
E-002 ELECTRICAL LEGEND
E-101 ELECTRICAL SITE PLAN
E-201 PARKING CANOPY EQUIPMENT ELECTRICAL PLAN
E-202 PARKING CANOPY LIGHTING ELECTRICAL PLAN
E-203 PARKING CANOPY LIGHTNING PROTECTION AND GROUNDING PLAN
E-204 EXISTING PUMP BUILDING ELECTRICAL DEMOLITION PLAN
E-205 EXISTING PUMP BUILDING ENLARGED ELECTRICAL PLAN
E-206 FLOW METER REPLACEMENT ELECTRICAL PLAN
E-301 ELECTRICAL SINGLE LINE DIAGRAM
E-401 ELECTRICAL SCHEDULES
E-402 ELECTRICAL WIRING DIAGRAMS EXAMPLES
E-501 TYPICAL ELECTRICAL DETAILS
E-502 TYPICAL ELECTRICAL DETAILS
E-503 TYPICAL ELECTRICAL DETAILS
E-504 TYPICAL ELECTRICAL DETAILS
COLLIER
COUNTY
COLLIER COUNTY
N
N
GULF
OF
MEXICO
ATLANTIC
OCEAN
CHKD:
DRWN:
PROJ:
DESN:
w w w t e t r a t e c h c o m
M A
R K
D A
T E
D E
S C
R I P
T I O
N B
Y
A
M
O
P
R O
J E
C T
S O
R L
A N
D O
I E
R
C
A D
S
H E
E T
F I L
E S
G
L
O C
A T
I O
N
M
A P
G
E N
E R
A
T
E S
I N
D E
X D
W G
M
A R
Q U
E Z
G
E R
M A
I N
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch, otherwise drawing not to scale
C o p y r i g h t
T e t r a e c h
200-08486-24001
R A
W
W
A T
E R
B
O
S T
P
U M
P
S
T A
T I O
N
I M
P R
O V
E M
E N
T S
C O
L L
I E
R
C
O U
N T
Y
P
U B
L I C
I L
I T
I E
S
C
H E
V R
O L
Y
S
U I T
E
E S
T E
R O
F
L
P H
100% SUBMITTAL
N
G I N
E E
R I N
G
B
U S
I N
E S
S
N
O
GENERAL NOTES
G-001
L O
C A
T I O
N
M
A P
G E
N E
R A
L
N
O T
E S
A
N D
D R
A W
I N
G
I N
D E
X
PC
GM
ML
1. IT IS THE CONTRACTORS RESPONSIBILITY TO DETERMINE THE EXACT LOCATION, DEPTH AND CHARACTER OF ALL UTILITIES
PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY RESPECTIVE UTILITY OWNERS AS LISTED BELOW AND FIELD
VERIFY LOCATIONS AND ELEVATIONS OF UTILITIES AT LEAST 48 HOURS IN ADVANCE OF WORK. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR DAMAGE CAUSED BY THEIR OPERATIONS.
- COLLIER COUNTY PUBLIC UTILITIES (WATER AND WASTEWATER DISTRICT): (239) 530-5335
- SUNSHINE STATE ONE CALL: 811 WWW.CALLSUNSHINE.COM
- IN ADDITION, PRIOR TO STARTING WORK, CONTRACTOR SHALL NOTIFY LOCAL PUBLIC SERVICE AGENCIES
INCLUDING SHERIFF AND FIRE DEPARTMENTS.
2. EXISTING UTILITIES AS SHOWN ARE APPROXIMATE LOCATIONS AND ARE BASED ON RECORD DRAWINGS AND HAVE NOT BEEN
FIELD VERIFIED. THE EXISTING UTILITIES SHOWN AND LISTED ABOVE SHALL NOT BE CONSTRUED AS BEING ALL INCLUSIVE OF
UTILITIES IN THE AREA. ANY INTERRUPTION OF SERVICE SHALL BE COORDINATED WITH THE OWNER OF THE UTILITY.
3. ALL DISTURBED AREAS SHALL BE RE-SODDED BY THE CONTRACTOR.
4. THE CONTRACTOR SHALL NOT PLACE ANY FILL MATERIALS WITHIN A WETTED DITCH OR WETLAND AREA WHEN WORKING
ADJACENT TO EITHER TYPE OF AREA.
5. WORK HOURS FOR THIS PROJECT SHALL BE AS FOLLOWS:
M-F: 7 AM - 7 PM
SATURDAY: 8 AM - 5 PM, REQUIRES 48 HOUR WRITTEN NOTICE AND WRITTEN APPROVAL FROM DISTRIBUTION MANAGER
SUNDAY: NO WORK ALLOWED.
6. CONTRACTOR SHALL SUPPLY THEIR OWN RESTROOM FACILITIES FOR THE DURATION OF THE PROJECT.
7. PRIOR TO BID PREPARATION, THE CONTRACTOR MUST BECOME FAMILIARIZED WITH THE OVERALL SITE CONDITION AND
PERFORM ADDITIONAL INVESTIGATIONS AS DETERMINED NECESSARY TO UNDERSTAND THE LIMIT AND DEPTH OF ROCK AND
EXPECTED ORGANIC SILT PEAT AREAS, ADEQUACY OF EXISTING MATERIALS AS FILL, DEWATERING REQUIREMENTS, CLEAN
FILL REQUIRED FROM OFFSITE, AND MATERIALS TO BE DISPOSED OF OFFSITE ALL OF WHICH WILL AFFECT THEIR PRICING. ANY
DELAY, INCONVENIENCE OR EXPENSE CAUSED TO THE CONTRACTOR DUE TO INADEQUATE INVESTIGATION OF EXISTING
CONDITIONS SHALL BE INCIDENTAL TO THE CONTRACT AND NO EXTRA COMPENSATION WILL BE ALLOWED. THE MATERIALS
ANTICIPATED TO BE ENCOUNTERED DURING CONSTRUCTION MAY REQUIRE DRYING PRIOR TO USE AS BACKFILL AND THE
CONTRACTOR MAY HAVE TO BRING IN MATERIALS AT NO EXTRA COST FROM OFFSITE TO MEET THE REQUIREMENTS FOR
COMPACTION AND PROPER FILL.
8. ALL PROPOSED IMPROVEMENTS SHALL BE PERFORMED PER COLLIER COUNTY STANDARDS, WHICH ARE AVAILABLE ON THE
COUNTY'S WEBSITE: WWW.COLLIERGOV.NET
9. THE CONTRACTOR, AT THE CONTRACTOR'S EXPENSE, SHALL IMMEDIATELY REPAIR ALL DAMAGES TO COUNTY'S MAINS AND
FACILITIES. IF THE REPAIR IS NOT MADE IN A TIMELY MANNER, AS DETERMINED BY COUNTY, COUNTY MAY PERFORM REQUIRED
REPAIRS AND CLEANUP. THE CONTRACTOR WILL BE CHARGED FOR ALL EXPENSES ASSOCIATED WITH THE REPAIR.
10. LOCATIONS AND ELEVATIONS OF EXISTING UTILITIES EXPOSED DURING CONSTRUCTION SHALL BE ACCURATELY RECORDED
ON THE CONSTRUCTION DRAWINGS. THE OWNER SHALL BE IMMEDIATELY NOTIFIED OF ANY CONFLICTS WITH PROPOSED
CONSTRUCTION.
11. THE CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO CONTROL TURBIDITY INCLUDING, BUT NOT LIMITED TO, THE
INSTALLATION OF TURBIDITY BARRIERS AT ALL LOCATIONS WHERE THE POSSIBILITY OF INFERRING SUSPENDED SOLIDS INTO
THE RECEIVING WATER BODY, EXISTS DUE TO THE PROPOSED WORK. TURBIDITY BARRIERS MUST BE MAINTAINED AT ALL
LOCATIONS UNTIL CONSTRUCTION IS COMPLETED AND DISTURBED SOIL AREAS ARE STABILIZED. THE CONTRACTOR SHALL
ALSO BE RESPONSIBLE FOR REMOVING THE BARRIERS. AT NO TIME SHALL THERE BE ANY OFF-SITE DISCHARGE WHICH
VIOLATES THE WATER QUALITY STANDARDS IN CHAPTERS 62-302 AND 62-4, FLORIDA ADMINISTRATIVE CODE.
12. THE CONTRACTOR SHALL MAINTAIN NORMAL TRANSPORT VEHICLE ACCESS TO FACILITIES AT ALL TIMES.
13. IN THE EVENT THAT THE POTABLE WATER SYSTEM IS CONTAMINATED (I.E. WATER DOES NOT MEET FEDERAL AND STATE
REQUIREMENTS) DUE TO THE CONSTRUCTION ACTIVITIES, THE CONTRACTOR SHALL BE RESPONSIBLE, UNDER THE DIRECTION
OF THE OWNER, OR THE STATE AND LOCAL REGULATORY AGENCY FOR CORRECTING ANY SUCH CONTAMINATION PROBLEM
INCLUDING DISINFECTION, TESTING AND OTHER CORRECTIVE ACTION.
PROJECT LOCATION WITHIN
THIS PROPERTY BOUNDARY
RAW WATER BOOSTER PUMP STATION SITE
SCALE: N.T.S.
DRAWING INDEX
AAP ALARM ANNUNCIATOR PANEL
AARV AUTOMATIC AIR RELEASE
VALVE
AAV AUTOMATIC AIR VENT
AB ANCHOR BOLT
ABAN ABANDON(ED)
ABRSV ABRASIVE
ABS ACRYLONITRILE BUTADIENE
STYRENE
ABV ABOVE
AC ALTERNATING CURRENT
ACCMP ASPHALT-COATED
CORRUGATED METAL PIPE
ACP ASBESTOS CEMENT PIPE
ADDM ADDENDUM
ADH ADHESIVE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AHD AHEAD
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
AMT AMOUNT
APRX APPROXIMATE(LY)
ARCH ARCHITECT(URAL)
AS ALUM SOLUTION
ASPH ASPHALT
ASSY ASSEMBLY
AVE AVENUE
A/C AIR CONDITIONING
A/VV AIR/VACUUM AIR VALVE
B
BAF BAFFLE
BCV BALL CHECK VALVE
BF BLIND FLANGE
BFV BUTTERFLY VALVE
BHP BRAKE HORSEPOWER
BI BLACK IRON
BITUM BITUMINOUS OR BITUMASTIC
B/L BASELINE
BLDG BUILDING
BLK BLOCK
BM BENCH MARK
BOC BACK OF CURB
BOT BOTTOM
BP BASE PLATE
BRG BEARING
BSP BLACK STEEL PIPE
BV BALL VALVE
BW BOTH WAYS
BWW BACKWASH WATER
C
CAP CAPACITY
CA COMPRESSED AIR
CAV COMBINATION AIR VALVE
CB CATCH BASIN
CCC CHLORINE CONTACT CHAMBER
CE CHLORINATED EFFLUENT
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CV CHECK VALVE
CI CAST IRON
CIP CAST IRON PIPE
CISP CAST IRON SOIL PIPE
CJ CONSTRUCTION JOINT
CKT CIRCUIT
C/L CENTER LINE
CL2 CHLORINE GAS
CLF CHAIN LINK FENCE
CLR CLEAR OR CLEARANCE
CLVT CULVERT
CMP CORRUGATED METAL PIPE
CMPA CORRUGATED METAL PIPE
ARCH
CMU CONCRETE MASONRY UNIT
CND CONDUIT
CNR CORNER
CO CLEAN OUT
CO2 CARBON DIOXIDE
COAG COAGULANT
COL COLUMN
COM COMMON
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCT(ION)
CONT CONTINUOUS
CONTR CONTRACT(OR)
COORD COORDINATE
CO COMPANY
CP CONCRETE PIPE
CPA CONCRETE PIPE ARCH
CPLG COUPLING
CPVC CHLORINATED POLYVINYL
CHLORIDE
CR CONCENTRIC REDUCER
CS CHLORINE SOLUTION
CSG CASING
CTV CABLE TELEVISION
CY CUBIC YARD
CYL CYLINDER
C&G CURB AND GUTTER
C/C CENTER TO CENTER
D
DAT DATUM
DBL DOUBLE
DC DIRECT CURRENT
DEMO DEMOLITION
DEPT DEPARTMENT
DESC DESCRIPTION
DET DETAIL
DF DIESEL FUEL
DI DUCTILE IRON
DIA DIAMETER
DIFF DIFFUSER
DIM DIMENSION
DIP DUCTILE IRON PIPE
DISCH DISCHARGE
DIR DIRECTION
DMH DROP MANHOLE
DN DOWN
DR DRAIN
DV DIAPHRAGM VALVE
DW DRIVEWAY
DWG DRAWING
DWV DRAIN, WASTE, AND VENT
E
E EAST
EA EACH
ECC ECCENTRIC
EF EACH FACE
EFF EFFLUENT
E/L EASEMENT LINE
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRICAL
EMER EMERGENCY
EMC ENCASE(MENT)
ENGR ENGINEER
EP EDGE OF PAVEMENT
EPDM ETHYLENE PROPYLENE DIENE
MONOMER
EPRF EXPLOSION PROOF
EQUIP EQUIPMENT
ER ECCENTRIC REDUCER
ESTM EASEMENT
EST ESTIMATE(D)
EW EACH WAY
EXC EXCAVATE
EXP EXPANSION
EXST EXISTING
EXST GR EXISTING GRADE
EXT EXTERIOR
EXTN EXTENSION
F
FAB FABRICATE(D)
FCA FLANGED COUPLING ADAPTER
FB FLAT BAR
FCV FLOW-CONTROL VALVE
FD FLOOR DRAIN
FDN FOUNDATION
FE FILTER(ED) EFFLUENT
FHY FIRE HYDRANT
FIG FIGURE
FIN FINISH(ED)
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FL FLUORIDE
FLG FLANGE(D)
FLL FLOW LINE
FLTR FILTER
FM FORCE MAIN
FPM FEET PER MINUTE
FPS FEET PER SECOND
FRP FIBERGLASS REINFORCED
PLASTIC
FT FOOT OR FEET
FUT FUTURE
FV FOOT VALVE
FW FINISHED WATER
FWP FACTORY WIRED PANEL
F/F FACE TO FACE
G
GA GAUGE
GAL GALLON(S)
GALV GALVANIZED
GIP GALVANIZED IRON PIPE
GJ GROOVE JOINT
GND GROUND
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPS GALLONS PER SECOND
GR GRADE
GRTG GRATING
GS GALVANIZED STEEL
GSP GALVANIZED STEEL PIPE
GSR GROUND STORAGE RESERVOIR
GST GROUND STORAGE TANK
GT GROUT
GV GATE VALVE
H
HB HOSE BIBB
HD HEAVY-DUTY
HDPE HIGH-DENSITY POLYETHYLENE
HDR HYDRAULIC
HFA HYDROFLUOSILICIC ACID
HGR HANGER
HGT HEIGHT
HNDRL HAND RAIL
HOA HAND-OFF-AUTO
HORIZ HORIZONTAL
HP HORSEPOWER
HPA HIGH PRESSURE AIR
HR HOUR
HVAC HEATING, VENTILATION, AND AIR
CONDITIONING
HWL HIGH WATER LEVEL
HWY HIGHWAY
HZ HERTZ
I
ID INSIDE DIAMETER
IN INCH(ES)
INF INFLUENT
INT INTERSECTION
INTR INTERIOR
INV INVERT
IP IRON PIPE
IPS INTERNATIONAL PIPE
STANDARD
IR INTERNAL RECYCLE
IW IRRIGATION WATER
J
JB JUNCTION BOX
JT JOINT
K
K KIP (1,000 LB)
KPL KICK PLATE
KV KILOVOLT
KVA KILOVOLT-AMPERE
KW KILOWATT
KWH KILOWATT-HOUR
L
L LEFT
LAB LABORATORY
LAM LAMINATE OR LAMINATION
LATL LATERAL
LAV LAVATORY
LEN LENGTH
LB POUND(S)
LF LINEAR FEET
LP LIGHT POLE
LS LIME SLURRY
LSS LIME STABILIZED SLUDGE
LVR LOUVER
LWL LOW WATER LEVEL
M
M METER
MAINT MAINTAIN OR MAINTENANCE
MAN MANUAL(LY)
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MCC MOTOR CONTROL CENTER
ME MITERED END
MECH MECHANICAL
MEG MATCH EXISTING GRADE
MFR MANUFACTURE(R)
MG MILLION GALLONS
MGD MILLION GALLONS PER DAY
MH MANHOLE
MI MILE(S)
MIN MINIMUM, MINUTE(S)
MISC MISCELLANEOUS
MJ MECHANICAL JOINT
ML MIXED LIQUOR
MO MASONRY OPENING
MON MONUMENT
MPH MILES PER HOUR
MPT MALE PIPE THREAD
MS MOTOR STARTER
MSP MOTOR STARTER PANEL
MTD MOUNTED
MV MOTORIZED VALVE
MW MANWAY
MWL MEAN WATER LEVEL
MWP MAXIMUM WORKING PRESSURE
N
N NORTH
NaOCl SODIUM HYPOCHLORITE
NE NORTHEAST
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NPF NATIONAL PIPE THREAD
NPT NATIONAL PIPE TAPER
(THREAD)
NPW NON-POTABLE WATER
NRS NON-RISING SYSTEM
NTS NOT TO SCALE
NW NORTHWEST
N/A NOT APPLICABLE
O
O2 OXYGEN
OC ON CENTER
OD OUTSIDE DIAMETER
ODP OPEN DRIP PROOF
OF OUTSIDE FACE
OH OVER HEAD
OHW OVER HEAD WIRE
OPP OPPOSITE
OPT OPTIONAL
OR OFFICIAL RECORDS
OSY OUTSIDE SCREW AND YOKE
O&M OPERATION AND MAINTENANCE
P
PA PROCESS AIR
PC POINT OF CURVE
PCM PERMANENT CONTROL
MONUMENT
PE PLAIN END
PG PRESSURE GAGE
PI POINT OF INTERSECTION
PL PLATE
P/L PROPERTY LINE
PNV PINCH VALVE
POB POINT OF BEGINNING
POJ PUSH-ON JOINT
POL POLYMER
PP POWER POLE
PPD POUNDS PER DAY
PPM PARTS PER MILLION
PREFAB PREFABRICATED
PRESS PRESSURE
PRV PRESSURE REDUCING VALVE
PRW PROCESS WATER
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH
ABSOLUTE
PSIG POUNDS PER SQUARE INCH
GAGE
PT POINT OF TANGENCY
PV PLUG VALVE
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
PW POTABLE WATER
PWR POWER
Q
Q FLOW
QTY QUANTITY
R
RAD RADIUS
RAS RETURN ACTIVATED SLUDGE
RC REINFORCED CONCRETE
RCB REINFORCED CONCRETE BOX
RCP REINFORCED CONCRETE PIPE
RCPA REINFORCED CONCRETE PIPE
ARCH
RD ROAD
RDCR REDUCER
REBAR REINFORCING STEEL
REF REFERENCE
REINF REINFORCE(D)(ING)(MENT)
REM REMOVE(ABLE)
REQ'D REQUIRED
RF RAISED FACE
RJ RESTRAINED JOINT
RM ROOM
RPBP REDUCED PRESSURE
BACKFLOW PREVENTER
RPM REVOLUTIONS PER MINUTE
RR RAILROAD
RT RIGHT
RVT RIVETED
RW RAW WATER
RWW RAW WASTEWATER
R/W RIGHT-OF-WAY
S
S SOUTH
SA SAMPLE LINE
SAN SANITARY
SCHED SCHEDULE
SD STORM DRAIN
SE SOUTHEAST
SECT SECTION
SEFF SECONDARY EFFLUENT
SF SQUARE FOOT OR FEET
SHT SHEET(ED)(ING)
SIG SIGNAL
SIM SIMILAR
SL SLUDGE
SLV SLEEVE
SM SHEET METAL
SOLN SOLUTION
SP SOIL PIPE, SPACE(ING)
SPEC SPECIFICATION
SPRT SUPPORT
SQ SQUARE
SS SANITARY SEWER
SSE SUBSTANDARD EFFLUENT
SST STAINLESS STEEL
ST STREET
STA STATION
STD STANDARD
STK STAKE
STL STEEL
STR STRAIGHT
STRUCT STRUCTURAL
SURF SURFACE
SV SOLENOID VALVE
SVCE SERVICE
SVW SERVICE WATER
SW SOUTHWEST
SWD SIDEWATER DEPTH
SWSH SURFACE WASH
SYM SYMBOL
SYMM SYMMETRICAL
S/W SIDEWALK
T
TAN TANGENT
TB TOP OF BEAM
TBM TEMPORARY BENCH MARK
TB-xx TEST BORING-xx (e.g. TB-1)
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TE TOTALLY ENCLOSED
TEFC TOTALLY ENCLOSED FAN
COOLED
TEL TELEPHONE
TENV TOTALLY ENCLOSED
NON-VENTILATED
THD THREAD(ED)
THK THICK(NESS)
TLM TELEMETRY
TOB TOP OF BANK
TOC TOP OF CURB
TOS TOE OF SLOPE
TOT TOTAL
TP TELEPHONE POLE
TS THICKENED SLUDGE
TV TELEVISION
TYP TYPICAL
T&B TOP AND BOTTOM
U
UD UNDERDRAIN
UG UNDERGROUND
ULT ULTIMATE
UN UNION
UON UNLESS OTHERWISE NOTED
UGE UNDERGROUND ELECTRIC
UTC UNDERGROUND TELEPHONE
CABLE
UTIL UTILITY
V
V VOLT(S)
VAC VACUUM
VAR VARIES
VC VERTICAL CURVE
VCP VITRIFIED CLAY PIPE
VEL VELOCITY
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W
W WATT, WEST
WAS WASTE ACTIVATED SLUDGE
WCO WALL CLEAN OUT
WF WIDE FLANGE
WH WALL HYDRANT
WL WATER LINE
WM WATER MAIN
WP WATER PROOF(ING), WORKING
POINT
WPR WORKING PRESSURE
WS WATER SURFACE
WSP WELDED STEEL PIPE
WT WEIGHT
WTP WATER TREATMENT PLANT
WW WASH WATER
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
WWTP WASTEWATER TREATMENT
PLANT
W/ WITH
W/O WITHOUT
X
XFER TRANSFER
Y
YD YARD(S)
YH YARD HYDRANT
YR YEAR(S) YR
REFERENCE SYMBOLS
LIST OF STANDARD ABBREVIATIONS
HATCHING LEGEND MECHANICAL/DRAFTING LEGEND
PIPING LEGEND
DETAIL REFERENCE
X
X-XX
DENOTES DRAWING NO
WHERE DETAIL IS LOCATED
DENOTES DETAIL NUMBER
IDENTIFICATION
DETAIL TITLE
DETAIL
X
SCALE:
DENOTES DRAWING NO
WHERE DETAIL IS LOCATED
DENOTES DETAIL NUMBER
IDENTIFICATION
ASPHALT OR CONCRETE
SURFACE (SIDEWALK OR
ROADWAY)
ROADWAY/SIDEWALK
OPEN CUT RESURFACE
SODDED OR SEEDED AND
MULCHED AREA OR
EXISTING WETLAND
EARTH
EXISTING PIPES,
STRUCTURES, EQUIPMENT
TO BE REMOVED
CAST-IN-PLACE
CONCRETE
GRATING
WETLAND
STEEL
TO BE DEMOLISHED
GROUT
PRECAST CONCRETE
PHANTOM LINE
HIDDEN LINE
VISIBLE LINE
CENTER LINE
BREAK LINE
DIMENSION LINES AND LEADERS
EXISTING PROPOSED
N/A N/A
MATCHLINE
1 3/32"
NOTE
FITTING/
APPURTENANCE
BEND
TEE
WYE
REDUCER
CAP/
BLIND FLANGE
PLUG
BUTTERFLY
VALVE
BALL VALVE
CHECK VALVE
GATE VALVE
PLUG VALVE
AUTOMATIC
CONTROL VALVE
PINCH VALVE
FLANGED
SINGLE-LINE DOUBLE-LINE
EXISTING PROPOSEDPROPOSEDEXISTING
MECHANICAL JOINT
SINGLE-LINE DOUBLE-LINE
EXISTING PROPOSEDPROPOSEDEXISTING
GROOVE JOINT
SINGLE-LINE DOUBLE-LINE
EXISTING PROPOSEDPROPOSEDEXISTING
SOLVENT WELD
SINGLE-LINE DOUBLE-LINE
EXISTING PROPOSEDPROPOSEDEXISTING
N/A N/A N/A N/A N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A N/A N/A N/A N/A
N/AN/AN/AN/A
CIVIL LEGEND
STORM SEWER
SANITARY SEWER
WATER
o o o o o o o o o o o o o o o o o o o
GUARD RAIL
xx xx xx xx
STEEL FENCE
x x x x x
WOOD FENCE
EMBANKMENT
TOP
BOTTOM
MONITORING WELL
HYDRANT
POWER POLE
UTILITY POLE
SEWER MANHOLE
SEWER VALVE
MANHOLE
MONUMENT
TREE - EVERGREEN
TREE - PALM TREE
FLARED END - RCP
STORM MANHOLE
WATER METER
WATER VALVE
WATER WELL
MW-X
FH
CO
SS
SV
MH-??
SD
WM
WV
WELL
LIGHT POLE
SEWER CLEANOUT
STORM CULVERT END
SPOT ELEVATION
XXXX.XX
TREE - DECIDUOUS
EASEMENT
R/W RAW WATER MAIN
RIGHT OF WAY LINE (R-O-W)
LIMITS OF CONTRUCTION
PROPOSED CONTOUR MAJOR130
129 PROPOSED CONTOUR MINOR
(LABEL OPTIONAL)
SANITARY SEWER
(FORCE MAIN)
VEGETATION
G-002
L E
G E
N D
S
A
N D
A B
B R
E V
I A
T I O
N S
PC
GM
MLCHKD:
DRWN:
PROJ:
DESN:
w w w t e t r a t e c h c o m
M A
R K
D A
T E
D E
S C
R I P
T I O
N B
Y
A
M
O
P
R O
J E
C T
S O
R L
A N
D O
I E
R
C
A D
S
H E
E T
F I L
E S
G
G
E N
D S
B
R E
V I A
T I O
N S
D
A R
Q U
E Z
G
E R
M A
I N
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch, otherwise drawing not to scale
C o p y r i g h t
T e t c h
200-08486-24001
R A
W
W
A T
O
S T
M
P
S
T A
T I O
N
I M
P R
O V
E M
E N
T S
C O
L L
I E
R
C
O U
N T
Y
P
U B
L
I L
I T
I E
S
C
H E
V R
O L
Y
S
U I T
E
E S
T E
R O
F
L
P H
N
G I N
E E
R I N
G
B
U S
I N
E S
S
N
O
H
S
T
S
W
P/L
P/L
P L
P L
R.O. SYSTEM TO
BE INSTALLED
INSIDE PUMP ROOM
(SEE NOTE 1)
EXISTING FLOW METER TO BE REPLACED
1. PARKING CANOPY TO BE CONSTRUCTED
OVER CONCRETE SLAB
2. CLEAN AND SEAL EXISTING CONC. SLAB
W
WELL
POTABLE WELL
TO BE INSTALLED
N: 684110.15
E: 452119.18
(SEE NOTE 1)
1" HDPE WM
EXISTING WASTEWATER
SUBSURFACE DISPOSAL SYSTEM
(SEE NOTE 2)
W
VALVE
WELL
VALVE
90 FOOT RADIUS
C-501
C-501
C-501
C-501
TRENCH
EXISTING
PAVEMENT LIMITS
SF
SF
SF
SF
SF
SF
SF
SF
SEDIMENT FENCE
C-502
90 FOOT RADIUS
CHKD:
DRWN:
PROJ:
DESN:
w w w t e t r a t e c h c o m
M A
R K
D A
T E
D E
S C
R I P
T I O
N B
Y
A
M
O
P
R O
J E
C T
S O
R L
A N
D O
I E
R
C
A D
S
H E
E T
F I L
E S
C
N
E R
T
E
P
L A
N D
A R
Q U
E Z
G
E R
M A
I N
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch, otherwise drawing not to scale
C o p y r i g h t
T e t c h
200-08486-24001
R A
W
W
A T
O
S T
M
P
S
T A
T I O
N
I M
P R
O V
E M
E N
T S
C O
L L
I E
R
C
O U
N T
Y
P
U B
L
I L
I T
I E
S
C
H E
V R
O L
Y
S
U I T
E
E S
T E
R O
F
L
P H
N
G I N
E E
R I N
G
B
U S
I N
E S
S
N
O
C-101
G E
N E
R A
L
S
I T
E
P
L A
N
PC
GM
ML
GENERAL SITE PLAN
SCALE: 1" = 40'
N
SCALE:
20' 40' 80'
1'' = 40'
PHOTO
SCALE: N.T.S.
PHOTO
SCALE: N.T.S.
PHOTO
PHOTO
NOTES
1. POTABLE WATER WELL AND REVERSE OSMOSIS (RO) SYSTEM - THE
POTABLE WATER SYSTEM WILL BE USED FOR THE UPGRADE TO THE
EXISTING RESTROOM, WHICH INCLUDES AN EXISTING TOILET, EXISTING SINK,
AND A NEW SHOWER. THE CONTRACTOR, THROUGH A QUALIFIED POTABLE
WATER WELL DRILLER LICENSED IN THE STATE OF FLORIDA, SHALL PROVIDE
A TURNKEY POTABLE WATER SYSTEM, INCLUDING BUT NOT LIMITED TO:
A.THE FINAL LOCATION AND INSTALLATION OF A 4-INCH WELL WITH A 1 HP -
20 GPM PUMP.
B.1-INCH HDPE WATER MAIN AND VALVES.
C.BACK FLOW PREVENTER.
D.HYDRO-PNEUMATIC TANK.
E.REVERSE OSMOSIS (RO) WATER TREATMENT SYSTEM.
F. CONNECTION TO THE BUILDING INTERIOR POTABLE WATER SYSTEM.
G.DISINFECTION.
H. WATER TESTING.
I. ELECTRICAL FROM THE BUILDING TO THE WELL.
J. DRILLING SLURRY CLEANUP.
K. START UP AND TESTING OF THE SYSTEM
L. 3 YEAR WARRANTY ON ALL PARTS AND LABOR.
M.ALL COLLIER COUNTY AND STATE PERMITS.
2. WASTEWATER SUBSURFACE DISPOSAL SYSTEM CLEANING AND INSPECTION
- THE CONTRACTOR SHALL LOCATE, CLEAN, AND INSPECT THE SEPTIC TANK,
DISTRIBUTION BOX, AND LEACH FIELD PIPING, INCLUDING BUT NOT LIMITED
TO:
A.LOCATION, CLEANING, AND INSPECTION OF ALL COMPONENTS.
B.PUMPING OUT AND CLEANING THE SEPTIC TANK AND DISTRIBUTION BOX.
C.INSPECTION REPORT TO DETERMINE THE SATISFACTORY OPERATION OF
THE WASTEWATER SUBSURFACE DISPOSAL SYSTEM.
D. ANY REQUIRED REPAIRS TO THE SYSTEM ARE NOT INCLUDED IN THE
SCOPE OF WORK AND WILL BE CONSIDERED ADDITIONAL WORK AS
APPROVED BY THE COUNTY.
CHKD:
DRWN:
PROJ:
DESN:
w w w t e t r a t e c h c o m
M A
R K
D A
T E
D E
S C
R I P
T I O
N B
Y
A
M
O
P
R O
J E
C T
S O
R L
A N
D O
I E
R
C
A D
S
H E
E T
F I L
E S
C
X
Y
A R
D
P
I P
I N
G
P
L A
N D
A R
Q U
E Z
G
E R
M A
I N
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch, otherwise drawing not to scale
C o p y r i g h t
T e t c h
200-08486-24001
R A
W
W
A T
O
S T
M
P
S
T A
T I O
N
I M
P R
O V
E M
E N
T S
C O
L L
I E
R
C
O U
N T
Y
P
U B
L
I L
I T
I E
S
C
H E
V R
O L
Y
S
U I T
E
E S
T E
R O
F
L
P H
N
G I N
E E
R I N
G
B
U S
I N
E S
S
N
O
C-102
E X
I S
T I N
G
Y
A R
D
P I P
I N
G
P
L A
N
PC
GM
ML
EXISTING YARD PIPING PLAN
SCALE: 1/16" = 1'-0"
N
SCALE:
8' 16' 32'
1/16" = 1'-0''
NOTES
1. THE EXISTING YARD PIPING PLAN IS TAKEN FROM THE HOLE MONTES - PUMP REPLACEMENTS -
RAW WATER BOOSTER PUMP STATION SITE PLAN DATED JULY 30, 2014.
2. IT IS THE CONTRACTORS RESPONSIBILITY TO DETERMINE THE EXACT LOCATION, DEPTH AND
CHARACTER OF ALL UTILITIES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY
RESPECTIVE UTILITY OWNERS AS LISTED BELOW AND FIELD VERIFY LOCATIONS AND
ELEVATIONS OF UTILITIES AT LEAST 48 HOURS IN ADVANCE OF WORK. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY THEIR OPERATIONS.
-COLLIER COUNTY PUBLIC UTILITIES (WATER AND WASTEWATER DISTRICT): (239) 530-5335
-SUNSHINE STATE ONE CALL: 811 WWW.CALLSUNSHINE.COM
-IN ADDITION, PRIOR TO STARTING WORK, CONTRACTOR SHALL NOTIFY LOCAL PUBLIC
SERVICE AGENCIES INCLUDING SHERIFF AND FIRE DEPARTMENTS.
3. EXISTING UTILITIES AS SHOWN ARE APPROXIMATE LOCATIONS AND ARE BASED ON RECORD
DRAWINGS AND HAVE NOT BEEN FIELD VERIFIED. THE EXISTING UTILITIES SHOWN AND LISTED
ABOVE SHALL NOT BE CONSTRUED AS BEING ALL INCLUSIVE OF UTILITIES IN THE AREA. ANY
INTERRUPTION OF SERVICE SHALL BE COORDINATED WITH THE OWNER OF THE UTILITY.
METER VAULT
ELEV. = 12.50
CONC. ENCASE
30" RAW WATER
ELEV. = 7.50
30"
13'-0"
3'-3"
36" X 30"
REDUCING
ELBOW
30" BUTTERFLY VALVE
(SEE NOTE NO. 1)
13'-4"
4'-6"
30"
RAW WATER
BOOSTER PUMP
STATION
TOP/SLAB EL. 12.50
1" SCHEDULE 80 PVC
HATCH DRAIN THRU
WALL ELEV. = 11.08
13'-0"
L.P. ELEV. = 4.92
35" HOLE WITH LINK
SEAL (TYP. 2 PLACES)
CONC. ENCASE
FIN. GRADE
36" RAW WATER ELEV. = 15.00
RESTRAINED
TYPE
JOINT
36" X 30"
REDUCING
ELBOW
3'-3"
ELEV. = 12.50
30" RAW WATER ELEV. = 6.2 ±
CONC. PIPE SADDLE
30" RAW WATER ELEV.ELEV. = 7.50
1'-6"
EXISTING FLOW METER
11.25° BEND
30" X 30" REDUCER
30" SLEEVE TYPE COUPLING
W/ EPOXY COATED SLEEVE &
STAINLESS STEEL BOLTS
CONC. PIPE SADDLE
RAW WATER
BOOSTER PUMP
STATION
FIN. GRADE
1'-6"
RAW WATER
BOOSTER PUMP
STATION
DEMOLISH
CLEAN,
COMPACTED
BACKFILL
DEMOLISH
CLEAN,
COMPACTED
BACKFILL
CHKD:
DRWN:
PROJ:
DESN:
w w w t e t r a t e c h c o m
M A
R K
D A
T E
D E
S C
R I P
T I O
N B
Y
A
M
O
P
R O
J E
C T
S O
R L
A N
D O
I E
R
C
A D
S
H E
E T
F I L
E S
C
F
O
W
M
E T
P
L A
C E
M E
N T
D
A R
Q U
E Z
G
E R
M A
I N
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch, otherwise drawing not to scale
C o p y r i g h t
T e t c h
200-08486-24001
R A
W
W
A T
O
S T
M
P
S
T A
T I O
N
I M
P R
O V
E M
E N
T S
C O
L L
I E
R
C
O U
N T
Y
P
U B
L
I L
I T
I E
S
C
H E
V R
O L
Y
S
U I T
E
E S
T E
R O
F
L
P H
N
G I N
E E
R I N
G
B
U S
I N
E S
S
N
O
C-103
E X
I S
T I N
G
F
L O
W
M
E T
E R
P I P
I N
G
A
M
O L
I T
I O
N
P L
C
T I O
N
PC
GM
ML
EXISTING PLAN
SCALE: 1/4" = 1'-0"
SCALE:
2' 4' 8'
1/4" = 1'-0''
N
EXISTING SECTION
SCALE: 1/4" = 1'-0"
DEMOLITION SECTION
SCALE: 1/4" = 1'-0"
PHOTO
SCALE: N.T.S.
PHOTO
PHOTO
SCALE: N.T.S.
PHOTO
L.P. ELEV. = 4.92
FIN. GRADE
36" RAW WATER ELEV. = 15.00
ELEV. = 12.50
EXISTING 30" RAW
WATER ELEV. = 6.2 ±
CONC. PIPE SADDLE
11.25° BEND
CONC. PIPE SUPPORT
RAW WATER
BOOSTER PUMP
STATION
CLEAN COMPACTED BACKFILL
PROLINE PROMAG
W 500 FLOWMETER
20"
5'-7" 2'-2"
10'-3"
18'-3"
36"X 20" REDUCER
4'-8"
8'-0"
30"X20" REDUCER
30" 90° BEND
5'-6"
25'-7"
CONC. PIPE SADDLE (TYP. OF 4)
20" 90° BEND
30" BUTTERFLY VALVE
(SEE NOTE NO. 1)
30"
13'-4"
PROLINE PROMAG
W 500 FLOWMETER
20"
5'-7" 2'-2" 10'-3"
18'-3"
36"X 20" REDUCER
CONC. PIPE SADDLE (TYP. OF 4)
20" 90° BEND
RAW WATER
BOOSTER PUMP
STATION
30" 90° BEND
NOTES:
1. THE RAW WATER BOOSTER PUMP STATION (RWBPS) TIMING FOR SHUTDOWN IS CRITICAL. THE CONTRACTOR
SHALL COORDINATE WITH THE RWBPS OPERATORS AS FOLLOWS:
A. JANUARY THROUGH MAY THE ALLOWABLE TIME IS 8 HOURS FOR A SHUTDOWN OF THE STATION.
B. JUNE THROUGH SEPTEMBER THE ALLOWABLE TIME IS 24 HOURS FOR A SHUTDOWN OF THE STATION.
C. OCTOBER THROUGH DECEMBER THE ALLOWABLE TIME IS 12 HOURS FOR A SHUTDOWN OF THE STATION.
34"
9" 9"
26"
(W/STRAP)
(W/O STRAP)
12"
5.5"
VARIES
PROVIDE 316 SS STRAP WHERE SHOWN
ON STRUCTURAL OR MECHANICAL DWGS
HOLE W/DIA 1/4"
LARGER THAN
ANCHOR BOLD
#4@12, MAX. E.F.
#3@12, TIES
CHKD:
DRWN:
PROJ:
DESN:
w w w t e t r a t e c h c o m
M A
R K
D A
T E
D E
S C
R I P
T I O
N B
Y
A
M
O
P
R O
J E
C T
S O
R L
A N
D O
I E
R
C
A D
S
H E
E T
F I L
E S
C
O
W
M
E T
P
L A
C E
M E
N T
D
A R
Q U
E Z
G
E R
M A
I N
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch, otherwise drawing not to scale
C o p y r i g h t
T e t c h
200-08486-24001
R A
W
W
A T
O
S T
M
P
S
T A
T I O
N
I M
P R
O V
E M
E N
T S
C O
L L
I E
R
C
O U
N T
Y
P
U B
L
I L
I T
I E
S
C
H E
V R
O L
Y
S
U I T
E
E S
T E
R O
F
L
P H
N
G I N
E E
R I N
G
B
U S
I N
E S
S
N
O
C-104
P R
O P
O S
O
W
M E
T E
R
P
I P
I N
G
P L
C
T I O
N
N
PROPOSED SECTION
SCALE: 1/4" = 1'-0"
PROPOSED PLAN
SCALE: 1/4" = 1'-0"
SCALE:
2' 4' 8'
1/4" = 1'-0''
NOMINAL
PIPE
DIAMETER
MINIMUM CONCRETE
PIER DIMENSIONS
STAINLESS
STEEL STRAPS
STAINLESS STEEL
ANCHOR BOLTS
"A1" "A2" "B" "C" "D" QUAN. "E" THICK QUAN. SIZE MIN. EMBED.
4" 18" 9" 6" 1.5" 8" 1 2" 1/4" 2 1/2" 6"
6" 20" 12" 6" 2" 8" 1 2" 1/4" 2 1/2" 6"
8" 22" 14" 6" 2.5" 8" 1 2" 1/4" 2 1/2" 6"
10" 24" 16" 8" 3" 8" 1 2" 1/4" 2 3/4" 9"
12" 26" 18" 8" 3.5" 8" 1 2" 1/4" 2 3/4" 9"
14" 28" 20" 8" 4" 8" 1 2" 1/4" 2 3/4" 9"
16" 30" 22" 8" 4.5" 8" 1 2" 1/4" 2 3/4" 9"
18" 32" 24" 8" 5" 12" 1 3" 3/8" 2 3/4" 9"
20" 34" 26" 8" 5.5" 12" 1 3" 3/8" 2 3/4" 9"
CONCRETE PIPE SUPPORT DETAIL
SCALE: N.T.S.
SECTION
SCALE: 3/4" = 1'-0"
PLAN
SCALE: 3/4" = 1'-0"
PROFILE
SECTION
NOTE:
DETECTABLE IDENTIFICATION TAPE SHALL BE INSTALLED DIRECTLY OVER CENTERLINE
OF THE PIPE AT 18-INCHES ABOVE THE PIPE.
IDENTIFICATION TAPE
FINISHED GRADE
FINISHED GRADE
IDENTIFICATION TAPE,
SEE NOTE
M
I N
DIP WATER MAIN
PAVED AREA TRENCH RESTORATION
DETAIL
SCALE: NTS
LOCATING TAPE
UNPAVED AREA TRENCH BACKFILL
DETAIL
SCALE: NTS
PIPE SEPARATION
DETAIL3
SCALE: NTS
TYPICAL VALVE SETTING
DETAIL
SCALE: NTS
BOLLARD
DETAIL6
SCALE: NTS
DETAIL5
SCALE: NTS
6" SCHED 40 STEEL PIPE
FILLED WITH CONCRETE
COLOR OF FINISH COAT
SHALL BE OSHA SAFETY
YELLOW
FINISHED
GRADE
9" (TYP)
3,000 PSI CONCRETE
2'-0"
CHKD:
DRWN:
PROJ:
DESN:
w w w t e t r a t e c h c o m
M A
R K
D A
T E
D E
S C
R I P
T I O
N B
Y
A
M
O
P
R O
J E
C T
S O
R L
A N
D O
I E
R
C
A D
S
H E
E T
F I L
E S
C
V
T
A I L
S D
A R
Q U
E Z
G
E R
M A
I N
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch, otherwise drawing not to scale
C o p y r i g h t
T e t c h
200-08486-24001
R A
W
W
A T
O
S T
M
P
S
T A
T I O
N
I M
P R
O V
E M
E N
T S
C O
L L
I E
R
C
O U
N T
Y
P
U B
L
I L
I T
I E
S
C
H E
V R
O L
Y
S
U I T
E
E S
T E
R O
F
L
P H
N
G I N
E E
R I N
G
B
U S
I N
E S
S
N
O
C-501
C I V
T
A I L
S
PC
GM
ML
EROSION AND SEDIMENT CONTROL GENERAL NOTES
NOTES:
ELEVATION
SECTION
PLAN
USE STITCHED LOOPS
OVER 2"x4" POSTS
NEWLY GRADED
OR DISTURBED
SLOPE
PROVIDE BASE COURSE
BACKFILL IN TRENCH
FILTER FABRIC
MATERIAL,
36" WIDE ROLLS
1. BURY BOTTOM OF FILTER FABRIC 6" VERTICALLY BELOW FINISHED GRADE.
2. 2"x4" TIMBER FIR OR STEEL FENCE POSTS.
3. STITCHED LOOPS TO BE INSTALLED DOWNHILL SIDE OF SLOPE.
4. COMPACT ALL AREAS OF FILTER FABRIC TRENCH.
INTERLOCKED 2"x4"
POSTS AND ATTACH
FILTER FABRIC
MATERIAL
ANGLE BOTH ENDS OF FILTER FABRIC
FENCE TO ASSURE SOIL IS TRAPPED
6' MAXIMUM SPACING
6" OVERLAP,
TYP
PT 'B'
F
L
O
W
STAKE, TYP
PT 'A',
SEE NOTE 1
PLAN
SECTION
NOTES:
SECTION
PLAN
2 STAKES PER BALE
STRAW BALE
SLOPING GROUND
F L O
W
NOTES:
ENDS OF BALES
OVERLAP 6" TYP
1.
2.
3.
4.
5.
STAKING OF BALES IS REQUIRED USING (2) 2"x2"x3' LONG WOOD STAKES OR
APPROVED EQUAL PER BALE.
DRIVE STAKES MINIMUM 12" INTO GROUND AND FLUSH WITH TOP OF BALES.
EMBED BALES MINIMUM OF 4" INTO GROUND SURFACE.
BIOFILTER BAGS TO BE USED, IF SPECIFIED.
BALES SHALL BE EITHER WIRE-BOUND OR STRING-TIED WITH THE BINDINGS
ORIENTED AROUND THE SIDES RATHER THAN OVER AND UNDER THE BALES.
S P
A C
I N
G
A
S
S
H O
W N
DIRECTION OF SURFACE FLOW
1. COMPLIANCE TO "TRENCH SAFETY ACT" IS REQUIRED FOR ALL EXCAVATIONS IN
EXCESS OF 5 FEET DEEP. CONTRACTOR SHALL COMPLY WITH THE U.S. DEPARTMENT
OF LABOR OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATIONS STANDARDS OSHA
29 CFR 1910.146, 'PERMIT-REQUIRED CONFINED SPACES' AND OSHA 29
2. IF AN INADVERTENT DISCOVERY OF ARCHEOLOGICAL MATERIALS OR HUMAN REMAINS
IS MADE, ALL WORK MUST STOP AND THE DISCOVERY MUST BE REPORTED TO THE
TRIBAL HISTORIC PRESERVATION OFFICE (THPO) AT 863-983-6549. IN THE CASE OF
DISCOVERY OF HUMAN REMAINS, NOTIFY THE SEMINOLE POLICE DEPARTMENT
IMMEDIATELY AT 954-966-6300, THEN CALL THE THPO.
3. DURING ANY ACTIVITY, IF SOIL OR GROUNDWATER CONTAMINATION IS ENCOUNTERED,
OR A SPILL OF HAZARDOUS MATERIAL OR OIL/GASOLINE OCCURS, STOP WORK IN THE
AREA AND CONTACT THE ENVIRONMENTAL RESOURCE MANAGEMENT DEPARTMENT
(ERMD) AT 954-965-4380 OR 863-763-4128 IMMEDIATELY.
4. CONSTRUCTION PERSONNEL INVOLVED ARE REQUIRED TO WATCH THE BEST
MANAGEMENT PRACTICES (BMP) VIDEO FOR WILDLIFE PROTECTION. WILDLIFE
BROCHURES MUST BE ON HAND DURING CONSTRUCTION AND POSTED ON BULLETIN
BOARDS. THE VIDEO AND BROCHURES ARE AVAILABLE FROM ERMD UPON REQUEST AT
863-902-3200 X 13411.
5. A NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT FOR
STORM WATER DISCHARGES FROM CONSTRUCTION SITES OVER ONE ACRE IS
REQUIRED UNDER THE EPA 2017 CONSTRUCTION GENERAL PERMIT ON INDIAN
COUNTRY. A STORMWATER POLLUTION PREVENTION PLAN (SWPPP) MUST BE
DEVELOPED PRIOR TO SUBMITTING THE NOTICE OF INTENT (NOI). A COMPLETE AND
ACCURATE NOI MUST BE SUBMITTED TO THE EPA AT LEAST 14 CALENDAR DAYS PRIOR
TO COMMENCING EARTH-DISTURBING ACTIVITIES TO BE ELIGIBLE FOR COVERAGE
UNDER THE NPDES PERMIT. THE EPA REQUIRES THE NOI TO BE SUBMITTED ONLINE.
INFO IS AVAILABLE AT
HTTPS://WWW.EPA.GOV/NPDES/ELECTRONIC-NOTICE-INTENT-ENOI. COPY
ERMDREQUEST@SEMTRIBE.COM ON YOUR SUBMITTAL. THE CONTRACTOR IS
RESPONSIBLE FOR PREPARATION AND SUBMISSION OF THE REQUIRED NPDES PERMIT
APPLICATION, SWPPP, AND NOI.
STRAW
BALES,TYP,
SPACE AS
SHOWN ON
PLANS
1. POINT 'A' MUST BE 6" MINIMUM HIGHER THAN PT 'B'.
2. STAKING OF BALES IS REQUIRED USING (2)2"x2"x3' LONG WOOD STAKES OR
APPROVED EQUAL PER BALE.
3. DRIVE STAKES MINIMUM 12" INTO GROUND AND FLUSH WITH TOP OF BALES.
4. EMBED BALES MINIMUM OF 4" INTO GROUND SURFACE.
5. BIOFILTER BAGS TO BE USED, IF SPECIFIED.
6. BALES SHALL BE EITHER WIRE-BOUND OR STRING-TIED WITH THE BINDINGS
ORIENTED AROUND THE SIDES RATHER THAN OVER AND UNDER THE BALES.
GENERAL NOTES SEDIMENT FENCE
FLOATING TURBIDITY BARRIER STRAW BALE IN DITCHES STRAW BALE FOR OVERLAND FLOW
DETAIL
SCALE: NTS
DETAIL
SCALE: NTS
DETAIL3
SCALE: NTS
DETAIL4
SCALE: NTS
CHKD:
DRWN:
PROJ:
DESN:
w w w t e t r a t e c h c o m
M A
R K
D A
T E
D E
S C
R I P
T I O
N B
Y
A
M
O
P
R O
J E
C T
S O
R L
A N
D O
I E
R
C
A D
S
H E
E T
F I L
E S
C
V
T
A I L
S D
A R
Q U
E Z
G
E R
M A
I N
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch, otherwise drawing not to scale
C o p y r i g h t
T e t c h
200-08486-24001
R A
W
W
A T
O
S T
M
P
S
T A
T I O
N
I M
P R
O V
E M
E N
T S
C O
L L
I E
R
C
O U
N T
Y
P
U B
L
I L
I T
I E
S
C
H E
V R
O L
Y
S
U I T
E
E S
T E
R O
F
L
P H
N
G I N
E E
R I N
G
B
U S
I N
E S
S
N
O
C-502
C I V
T
A I L
S
PC
GM
ML
| Sheets and Views |
| G-000 COVER SHEET |
| G-001 LOCATION MAP, GENERAL NOTES, AND DRAWING INDEX |
| G-002 LEGENDS AND ABBREVIATIONS |
| C-101 GENERAL SITE PLAN |
| C-102 EXISTING YARD PIPING PLAN |
| C-103 EXISTING FLOW METER PIPING AND DEMOLITION PLAN & SECTION |
| C-104 PROPOSED FLOW METER PIPING PLAN & SECTION |
| C-501 CIVIL DETAILS |
| C-502 CIVIL DETAILS |
| A-001 EXISTING PUMP BUILDING |
File details come from the government source that posted it. Updated .