This document is an AFMC Form 807 detailing Recommended Quality Assurance Provisions and Special Inspection Requirements for a federal contract opportunity involving a Fan Frame Weldment for F108 aircraft. The form specifies quality control and inspection standards, including compliance with FAR 52.246-2 through -6, ISO 9001:2015, AS 9100, and NATO AQAP2070 quality requirements. The document includes a National Stock Number 2840012631563PN and confirms no use of Ozone Depleting Substances (ODS) in the manufacturing process. Key technical contacts are Michael A. Tapley (Item Manager, 405-582-9040) and Rodney Mesenbrink (Equipment Spec, 405-761-7602), with the technical authority being Austin T. Skaggs from AFLCMC/LPSDE.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RECOMMENDED QUALITY ASSURANCE PROVISIONS
AND SPECIAL INSPECTION REQUIREMENTS
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
2840012631563PN
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
tapley, Michael A / 405-582-9040
6. EQUIPMENT SPEC / PHONE
Mesenbrink, Rodney / 405-761-7602
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
X OTHER (Describe in Block 8)
8. REMARKS
Skaggs, Austin TNAME: 27 NOV 2023DATE:
Contract Quality Requirements/Special Inspection Requirements:
Standard inspection Far 52.246-2,-3,-4,-5,-6 AS APPLICABLE TO CONTRACT
Higher Level Contract Quality Requirements:
FAR 52-246-11, ISO 9001:2015, AS 9100, NATO AQAP2070, (or equivalent)
ODS CERTIFICATION (Provided in lieu of Block 8a./Ozone Depleting Substances):
The subject requirement does not include any specification, standard, drawing, or other document that mandates the use of a Class I ODS in the manufacture, test, operation, or maintenance of any system, subsystem, item, component, or process; nor does it establish a test, operation, or maintenance requirement that can only be met by use of a Class I
ODS.
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
PREVIOUS SOURCENO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
I
11. SIGNATURE OF TECHNICAL AUTHORITY
Skaggs, Austin T
ORGANIZATION / SYMBOL
AFLCMC / LPSDE
PHONE
580-670-1140 / 884-3308
DATE
27 NOV 2023