36L79726Q0009 0002 - Q A Responses.pdf
PDF 103 KB Posted
- Solicitation number
- 36L79726Q0009
- Issued by
-
Department of Veterans Affairs
About this file
This document is Amendment #0002 to Request for Quote (RFQ) 36L79726Q0009 issued by the Department of Veterans Affairs Enterprise Procurement Office Acquisition Service 7 in Hines, Illinois, effective August 18, 2026. The amendment provides clarifications and answers to nine questions submitted by interested parties regarding a laundry equipment procurement project.
Key clarifications include: existing machine spacing can be maintained around non-moving and moving equipment; the epoxy floor replacement requirement has been removed as the site does not have epoxy floors; Uninterrupted Power Supply (UPS) backup is required only for the central washer control system with minimum 2-hour capacity; new dryers shall be pass-through machines with internal lint screens and external lint collection points, integrating with the facility's existing conveyor-based system, and the rooftop lint collector will be removed; the dryers shall support existing pass-through conveyor operations; the existing staph barrier wall will remain with cleaned glass and replacement of cracked or shattered sections; there are no existing washer loading chutes, so the facility's overhead rail loading system will be used instead; replacing washers with like-for-like pocket configurations (2 and 4 pocket machines) is acceptable rather than the specified 3-pocket minimum; and a single integrated color touchscreen control interface is acceptable for the blanket folder and stacker system provided it offers full automatic and manual operation, self-testing, fault display, and diagnostics for both components. Offerors must acknowledge receipt of this amendment prior to the deadline specified in the solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36L79726Q0009 0001 - Extend Response Date.pdf | ||
| RFQ 36L79726Q0009 OKLAHOMA CITY OK.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5. PROJECT NUMBER (if applicable)
CODE7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO. 1. CONTRACT ID CODE
FACILITY CODECODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER 16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30 PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243
(Type or print) (Type or print)
(Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code)
(If other than Item 6)
(Specify type of modification and authority)
(such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer)
1 5
0002 08-18-2026
36L797
Department of Veterans Affairs Enterprise Procurement Office Acquisition Service 7 Building 37 1st Avenue, One Block North of Cermak Hines, IL 60141
To all Offerors/Bidders
36L79726Q0009
07-22-2026
X
X X
X 1
Request for Quote (RFQ) 36L79726Q0009 is amended to provide Answers to Questions on page 2-5 of this amendment as a result of Questions submitted by interested parties.
Maria E. Alba Contract Specialist
RFQ 36L79726Q0009
Amendment # 0002
The following are Questions and Answers pertaining to subject RFQ answered by VA:
Question 1.
“Section E.2 – Evaluation of Quotes – 3. Technical Documentation/ Information – Space Utilization
A minimum requirement around all non-moving pieces is a space allowance of 24 inches. Egress above 24 inches shall be detailed. The minimum requirement around all moving pieces is a space allowance of 36 inches.”
To accommodate existing equipment placement and maximize operational space in the laundry, can you please clarify if current spacing between and around machines can be maintained?
Answer 1.
Yes, the spacing between and around the machines can be maintained.
Question 2.
“Section B.2 – Statement of Work – 2. Site Specific Project Requirements – 2.10 All areas of the epoxy floor that is exposed due to the removal or relocation of braces, supports, and equipment shall be replaced with the same material.”
The site does not have epoxy floors. Can you please clarify if this statement can be removed?
Answer 2.
Yes, Statement of Work section 2.10 is hereby removed as a requirement.
Question 3.
“Section B.2 – Statement of Work – 5. Electrical Requirements – 5.4.5 Uninterrupted Power Supply (UPS) shall be installed for all equipment supplied.
(Minimum 2-hour back-up).”
Can you please confirm if the Uninterrupted Power Supply is intended for use for only the central washer control system?
RFQ 36L79726Q0009
Amendment # 0002
Answer 3.
Yes, UPS is required for only the central washer control system.
Question 4.
“Section B.3 – Technical Specifications – Item #0001
Furnish and install two (2) each 400/500-pound production gas heated dryers with external to the machine lint collection.”
Per the site visit on August 4th, 2026, it was clarified with the site that the existing roof top lint collector will be removed, and it was acceptable to install a new dryer with an internal lint screen with an external to the dryer lint collection point. Can you please confirm this scope is accurate to the formal solicitation?
Answer 4.
Confirmed. The proposed configuration is acceptable. The existing rooftop lint collector will be removed. The new dryers shall utilize an internal lint screen with an external-to-the-dryer lint collection point, as described in the clarification. The solicitation shall be revised as necessary to reflect this requirement.”
Question 5.
“Section B.3 – Technical Specifications – Item #0001
The 400/500-pound dryers shall be non-pass thru with 2-way tilting for loading and unloading.”
The existing machines are currently pass thru machines. Are the dryers to be pass-thru or non-pass thru machines?
Answer 5.
The dryers shall be pass-through machines and shall integrate with the facility's existing conveyor-based laundry system/workflow. The solicitation language identifying the dryers as non-pass-through will be revised at the time of award. The required loading, unloading, and tilting configuration shall support the existing pass-through conveyor operation.
RFQ 36L79726Q0009
Amendment # 0002
Question 6.
“Section B.3 – Technical Specifications – Item #0002 Large Washer Extractors A staph barrier wall shall be built around the washers (or other suitable/approved arrangement for soiled separation) and into the system to prevent cross-contamination.”
Per the site visit on August 4th, 2026, it was discussed that the existing staph barrier wall would remain, with the existing glass staph barrier wall to be cleaned, and any cracked or shattered glass will be replaced. The contractor will remove a portion of the wall for the removal and installation of the washer extractors, maintaining a separation between the soiled side and clean side of the laundry.
Answer 6.
Confirm, that the existing staph barrier wall is to remain, with the existing glass staph barrier wall to be cleaned, and any cracked or shattered glass will be replaced. The contractor will remove a portion of the wall for the removal and installation of the washer extractors, maintaining a separation between the soiled side and clean side of the laundry.
Question 7.
“Section B.3 – Technical Specifications – Item #0002 Large Washer Extractors – Ordering Data – 3.
The existing washer loading chutes shall be rebuilt and used with the new split pocket pass through type washer. The contractor will provide new washer loading chutes that will accommodate the equipment offered.”
There are no existing washer loading chutes. Can this statement be removed from the solicitation requirements?
Answer 7.
There are no existing washer loading chutes. The facility currently utilizes an overhead rail system for loading the washer extractors. Therefore, the requirement in Section B.3, Item #0002, Ordering Data – 3, requiring existing washer loading chutes to be rebuilt and reused will be removed from the SOW at time of award.
RFQ 36L79726Q0009
Amendment # 0002
Question 8.
“Section B.3 – Technical Specifications – Item #0002 Large Washer Extractors – Ordering Data – 4.
Multiple compartment minimum of 3, split pocket pass through type.”
The site currently has 2 and 4 pocket machines. Can you please specify if replacing the washers with like for like pockets is acceptable?
Answer 8.
Yes, it is acceptable.
Question 9.
“Section B.3 – Technical Specifications – Item #0003 – Blanket Folder System – k The blanket stacker conveyor shall operate as an integral part of the blanket folder cross-folder.
Section B.3 – Technical Specifications – Item #0003 – Blanket Folder System – n The blanket stacker shall be color touch screen controls and information systems that incorporate automatic/manual machine operation, self-testing, fault display and built-in diagnostics / microprocessor controlled.”
Can you please validate if the stacker is incorporated as an integral part of the blanket folding system, if one color touch screen on the blanket folder (that operates both the blanket folder and stacker) is acceptable for this system.
Answer 9.
Yes, a single color touchscreen control interface is acceptable, provided the stacker is fully integrated with the blanket folding system and the single interface provides all required automatic and manual operation, self-testing, fault display, diagnostic, and system control functions for both the folder and stacker.