36E77620R0008-087.pdf
PDF Posted
- Solicitation number
- 36E77620R0008
About this file
This document package includes plans and drawings for the Reconfigure 2J Basement Floor project at the Dallas VA Medical Center, as well as a notice for the related federal contract opportunity. The project involves renovating and expanding the first-floor lab in Building 2J, including relocating two services to the basement and moving another service out of its current space. Drawings show proposed demolition, build back dimensions, electrical plans, and finish plans. The solicitation will be a Request for Proposal conducted under FAR Parts 15, 19, and 36 as a total Service-Disabled Veteran-Owned Small Business set-aside for design-build services. The construction magnitude is estimated between $1 million and $2 million. The performance period is approximately 200 calendar days from notice to proceed. The NAICS code is 236220 with a $36.5 million size standard. The solicitation is expected in late January to early February 2020.
36E77620R0008 ATTACHMENT 10 - Construction Package.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36E77620R0008 0001.pdf | ||
| Solicitation - 36E77620R0008 - 5-26-2020.pdf | ||
| 36E77620R0008-089.pdf | ||
| 36E77620R0008-080.pdf | ||
| 36E77620R0008-092.docx | DOCX document | |
| 36E77620R0008-094.pdf | ||
| 36E77620R0008-088.pdf | ||
| 36E77620R0008-082.pdf | ||
| 36E77620R0008-077.docx | DOCX document | |
| 36E77620R0008-079.pdf | ||
| 36E77620R0008-081.pdf | ||
| 36E77620R0008-078.pdf | ||
| 36E77620R0008-084.pdf | ||
| 36E77620R0008-085.pdf | ||
| 36E77620R0008-086.pdf | ||
| 36E77620R0008-090.pdf | ||
| 36E77620R0008-083.pdf | ||
| 36E77620R0008-091.doc | DOC document | |
| 36E77620R0008-093.docx | DOCX document | |
| 36E77620R0008-095.pdf |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
UP
STAIRWAY 6
S16
RESTROOM,
MEN
1B219
RESTROOM,
WOMEN
1B218
STAIRWAY 5
S15
SUPERVISOR
OFFICE
1B-400G
CELLULAR &
IMMUNOPATHOLOGY
SUPERVISOR
1B-406A
XXXXX
1B-217
HAC
1B520T
MEN
1B520T
ADMISTRATIVE
PROGRAM
MANAGER
1B520SB
CHIEF
PHARMACY
SERVICE
1B520SA
ASSISTANT
CHIEF
PHARMACY
SERVICE
1B520SC
PHARMACY
ADMISTRATIVE
OFFICES
1B520
SHARED LAB
SUPPLY ROOM
1B-424A
CASHIER AREA
PHARMACY
ENTRY
CORRIDOR
CORRIDOR
CONSULTATION
ROOM
1B220D
BED
UTILIZATION
1B220C
OFFICE
1B328BA
CONSULTATION
ROOM
1B220E
CLINICAL
PROGRAM
MANAGER
1B220A
DISCHARGE
CENTER
1B220
ADMIN. OFFICE
1B220B
THERAPEUTIC
PHLEBOTOMY
1B330
COMMUNICATION
ROOM
1-4A
ELECTRICAL
ROOM
1-4B
OFFICE
XXXX
PHARMACY
COUNTER
XXXX
OFFICE
XXXX
AGENT
CASHIER
CLOSET,
STORAGE
1B221A
SATORAGE,
GENERAL
1B226
CUBICLE AREA
1B221
OFFICE
1B221D
OFFICE
1B221F
TRAINING
ROOM
1B221E
RETURNING
COMBAT VETS.
1B214
RETURNING
COMBAT VETS.
1B214A
OFFICE
1B221C
WAITING ROOM
1B222
STORAGE,
WHEEL CHAIR
1B000
ELECTRICAL
1-6B
COMMUNICATION
ROOM
1B223
CLOSET,
STORAGE
1B222CA
HAC
1B225
OFFICE
1B221B
OFFICE
1B222C
ELECTRICAL
ROOM
1B224
NUTRITION
CLASSROOM
1B222A
OFFICE
1B222B
WOMENS
RESTROOM
1B-332
HISTOLOGY
STORAGE
1B-328B
MENS
RESTROOM
1B-336
WOMENS
LOCKER ROOM
1B-336A
HISTOLOGY
CUTTING &
STAINING
1B-328
TRANSFUSION
MEDICINE UNIT
1B-301
TRANSFUSION
MEDICINE UNIT
1B-301A
XXXXX
1B-217
XXXXX
1B-217A
CYTOLOGY,
IMMUNOLOGY
1B-328A
RESTROOM
1B-216
CLIENT
SERVICES UNIT
1B-311
ABC SYSTEM
1B-311A
RESTROOM
1B-215
DN
UP
UP
DN
221.57 SF
SHOWROOM 2
BB117
339.81 SF
STORAGE
BB116
125.46 SF
GAS STORAGE
#2
125.04 SF
GAS A BOTTLE
STORAGE
126.67 SF
EMS STORAGE
1,742.59 SF
ENGINEERING
SUBSTATION
BB450
249.43 SF
GAS STORAGE
#1
268.73 SF
SAFETY TEAM
BB220K2JD
167.75 SF
LAB TEAM
BB220L
54.5 SF
STORAGE
BB220F2JD
380.54 SF
IMAGING TEAM
BB220E2JD
160.69 SF
TV SHOP
BB220M2JD
350.17 SF
CONFERENCE
BB220D2JD
100.66 SF
OFFICE
BB220C2JD
110.35 SF
OFFICE
BB220B2JD
128.23 SF
STORAGE
BB220G2JD
589.34 SF
STORAGE
BB118B
1,347.05 SF
SHOWROOM 1
BB118
318.76 SF
STAIRWAY 5
2JS5
3,157.04 SF
BACK DOCK
1,163.89 SF
CORRIDOR
BB
311.47 SF
SLIDE
STORAGE
B05
897.86 SF
BIOMED
BB220
246.78 SF
FILE STORAGE
B05A
205.02 SF
FIRE PROT.
ROOM
B06
1,469.61 SF
SERVICE BAY
B5
230.09 SF
ELECTRICAL
ROOM
B4B
150.84 SF
SERVER ROOM
B4A
3,097.28 SF
SERVICE BAY
B6
257.63 SF
ELECTRICAL
ROOM
B5B
112.67 SF
SERVER ROOM
B5A
1,531.26 SF
SERVICE BAY
B4
196.44 SF
STAIRWAY 6
XXXXX
211.38 SF
OFFICE
BB218D
343.44 SF
OFFICE
BB217A
208.9 SF
OFFICE
BB218C
202.86 SF
OFFICE
BB218B
OFFICE
312.02 SF
HALL
BB218
73.77 SF
WOMENS
BB113
939.8 SF
OFFICE
BB112
73.03 SF
MENS
BB114
1,899.11 SF
CORRIDOR
643.42 SF
CORRIDOR
BB
BUILDING 2J
Basement
Section "C1"
1 2 3 4
7891011
4' -0
" 3'-6" 3'-6"
3' -6
5' -6
7' -0
+42"
AFF
1 2 3 4
10 11 12 13
16 17 18
19 20 21 22 23
24 25 29282726
+42"
AFF
5'-0"
4' -0
XXXX
214-857-1021
MARCH 19, 2019
VA MEDICAL CENTER NORTH TEXAS
4500 S. LANCASTER ROAD
DALLAS, TEXAS 75216
CONTACT: DATE: PAGE:PROJECT: 549-19-XXX
NTX REMODEL LAB
CLINICAL ADDITION FIRST FLOOR & BASEMENT
PAGE TITLE:
AREAS OF WORK
DRAWING SCALE:
1 OF 51/8" = 1'-0"
BASEMENT CLINICAL ADDITION1 SCALE: 1/8" = 1'-0"
FIRST FLOOR CLINICAL ADDITION2 SCALE: 1/8" = 1'-0"
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text A
RESTROOM,
MEN
1B219
RESTROOM,
WOMEN
1B218
XXXXX
1B-217
CONSULTATION
ROOM
1B220D
BED
UTILIZATION
1B220C
CONSULTATION
ROOM
1B220E
CLINICAL
PROGRAM
MANAGER
1B220A
DISCHARGE
CENTER
1B220
ADMIN. OFFICE
1B220B
RETURNING
COMBAT VETS.
COMBAT VETS.
OFFICE
1B221B
HISTOLOGY
STORAGE
1B-328B
HISTOLOGY
CUTTING &
STAINING
1B-328
XXXXX
1B-217
XXXXX
1B-217A
RESTROOM
1B-216
CLIENT
SERVICES UNIT
1B-311
ABC SYSTEM
RESTROOM
1B-215
5 76
12 13
5'-0"
4' -0
4LF
4LF
221.57 SF
SHOWROOM 2
BB117
589.34 SF
STORAGE
BB118B
1,347.05 SF
SHOWROOM 1
BB118
4' -0
XXXX
214-857-1021
MARCH 19, 2019
VA MEDICAL CENTER NORTH TEXAS
4500 S. LANCASTER ROAD
DALLAS, TEXAS 75216
CONTACT: DATE: PAGE:PROJECT: 549-19-XXX
NTX REMODEL LAB
CLINICAL ADDITION FIRST FLOOR & BASEMENT
PAGE TITLE:
DEMOLITION PLANS
DRAWING SCALE:
2 OF 51/8" = 1'-0"
ENLARGED 3/8" = 1'-0"
BASEMENT CLINICAL ADDITION1 SCALE: 1/8" = 1'-0"
FIRST FLOOR CLINICAL ADDITION2 SCALE: 1/8" = 1'-0"
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text A
643.42 SF
CORRIDOR
BB
MAS CHIEF
MAS SECTION
CHIEFS
MAS ASST
CHIEF
Chief
Amb Care
AMB AO
MAS RECEP
AMB RECEP
F r i d g e
AMB CARE
Patient
Advocate
R
PM
FF
FF
FF R
PM
FF
R
PM
FF
RPM
FF
LF
LF
4LF
MAS FILE STORAGE
MAS AO
SWING SPACE
BREAKROOM
MAS CHIEF
Secretary
MAS/AMB OFFICE
MAS
Mobility Manager
5H filing cabinets
5H filing cabinets 3H filing cabinets 5H filing cabinets
Printer/ mail area
Analyst
ADPAC
Secretary
POP H.N.
ADMIN SUPPORT
ASST
AMB CARE
OFFICE
Section Chiefs
4LF
339.81 SF
BB116
643.42 SF
CORRIDOR
BB
AMB CARE/MAS
CONFERENCE ROOM
S T
O R
A G
E
3'-3 5/8" 13'-10 1/4" 0'-6" 3'-0" 10'-1 3/4"
3'-0" 1'-10 5/8" 11'-7 1/8"
23'-9 1/2" 3'-0" 1'-0" 5'-0" 7' -7
/8
9'
-5
/8
8' -2
/8
11'-7 1/8"
1' -6
0'
-5
/2
3' -0
'-8
/4
3' -0
2'
-9
/8
3' -9
/8
8' -2
/8
30'-8 1/8"
5'-11" 3'-0" 2'-0 1/2" 3'-0"0'-6"
10'-0" 5'-3 3/8"
3' -6
3'-5 1/4" 3'-0"1'-6 3/4"3'-0" 8'-10" 7'-4 1/4" 15'-6 1/4"
0' -4
3'
-0
2' -8
/4
5' -0
5'
-0
/8
12'-0"
'-0
'-0
'-5
/8
SUPERVISOR
CELLULAR &
IMMUNOPATHOLOGY
SUPERVISOR
1B-406A
ADMISTRATIVE
PROGRAM
MANAGER
1B520SB
1B520SC
SHARED LAB
SUPPLY ROOM
1B-424A
PHARMACY
ENTRY
CORRIDOR
RETURNING
COMBAT VETS.
COMBAT VETS.
OFFICE
1B221B
HISTOLOGY
STORAGE
1B-328B
HISTOLOGY
CUTTING &
STAINING
1B-328
CLIENT
SERVICES UNIT
1B-311
ABC SYSTEM
STAFF
RESTROOM
ADA
FEMALE
ONLY
ADA
UNISEX
ADA
MEN'S
RESTROOM
GURNEY
12 13
14 15 16
BARIATRIC
RESTROOM
EXIT
ENTRY
SPECIMEN
HOLDERS
OPEN
STORAGE
CHECK - IN
WAITING
BARIATRIC
ICE
MACHINE
7'-0"
'-0
'-2
/8
4' -1
7/
8"
5'-2"
5' -2
/4
7'-3 1/2"
6'-7 3/4"
10'-0"
5'-0"
XXXX
214-857-1021
MARCH 19, 2019
VA MEDICAL CENTER NORTH TEXAS
4500 S. LANCASTER ROAD
DALLAS, TEXAS 75216
CONTACT: DATE: PAGE:PROJECT: 549-19-XXX
NTX REMODEL LAB
CLINICAL ADDITION FIRST FLOOR & BASEMENT
PAGE TITLE:
BUILD BACK DIMENSIONS
DRAWING SCALE:
3 OF 5SEE DRAWING
BASEMENT CLINICAL ADDITION1 SCALE: 1/2" = 1'-0"
FIRST FLOOR CLINICAL ADDITION2 SCALE: 1/4" = 1'-0"
643.42 SF
CORRIDOR
BB
R
PM
FF
FF
FF R
PM
FF
R
PM
FF
RPM
FF
LF
LF
4LF
4LF
339.81 SF
BB116
230.09 SF
643.42 SF
CORRIDOR
BB
AMB CARE/MAS
CONFERENCE ROOM
HAC
1B520T
ADMISTRATIVE
PROGRAM
MANAGER
1B520SB
CHIEF
PHARMACY
SERVICE
1B520SA
ASSISTANT
CHIEF
PHARMACY
SERVICE
1B520SC
PHARMACY
ADMISTRATIVE
OFFICES
1B520
PHARMACY
ENTRY
CORRIDOR
ELECTRICAL
ROOM
1-4B
PHARMACY
COUNTER
XXXX
OFFICE
XXXX
RETURNING
COMBAT VETS.
1B214
RETURNING
COMBAT VETS.
1B214A
OFFICE
1B221B
HISTOLOGY
STORAGE
1B-328B
HISTOLOGY
CUTTING &
STAINING
1B-328
CLIENT
SERVICES UNIT
1B-311
ABC SYSTEM
1B-311A
STAFF
RESTROOM
ADA
FEMALE
ONLY
ADA
UNISEX
ADA
MEN'S
RESTROOM
GURNEY
12 13
14 15 16
BARIATRIC
RESTROOM
EXIT
ENTRY
SPECIMEN
HOLDERS
OPEN
STORAGE
CHECK - IN
WAITING
BARIATRIC
ICE
MACHINE
XXXX
214-857-1021
MARCH 19, 2019
VA MEDICAL CENTER NORTH TEXAS
4500 S. LANCASTER ROAD
DALLAS, TEXAS 75216
CONTACT: DATE: PAGE:PROJECT: 549-19-XXX
NTX REMODEL LAB
CLINICAL ADDITION FIRST FLOOR & BASEMENT
PAGE TITLE:
ELECTRICAL DATA PLANS
DRAWING SCALE:
4 OF 5SEE DRAWING
4LF
4LF
GENERAL NOTES FOR SUITE:
1. ALL WALLS TO BE PAINTED
2. ONE VINYL ACCENT WALL PER
ROOM/HALLWAY/WAITING ROOM
3. CHAIR RAIL THROUGHOUT WAITING
4. RUBBER BASE
5. LUXURY VINYL PLANK IN WAITING ROOM,
BREAK ROOM AND CORRIDORS
6. CARPET IN OFFICES
7. SOLID SURFACE ON ALL COUNTER TOPS
8. HAND RAIL/CRASH RAIL IN PUBLIC AREAS
GENERAL NOTES FOR CONFERENCE ROOM:
1. ALL WALLS TO BE PAINTED
2. ONE VINYL ACCENT WALL
3. RUBBER BASE
4. LUXURY VINYL PLANK
5. SOLID SURFACE ON ALL COUNTER TOPS
SUPERVISOR
OFFICE
1B-400G
CELLULAR &
IMMUNOPATHOLOGY
SUPERVISOR
1B-406A
ADMISTRATIVE
PROGRAM
MANAGER
1B520SB
1B520SA
SERVICE
1B520SC
SHARED LAB
SUPPLY ROOM
1B-424A
PHARMACY
ENTRY
CORRIDOR
RETURNING
COMBAT VETS.
1B214
RETURNING
COMBAT VETS.
1B214A
OFFICE
1B221B
HISTOLOGY
STORAGE
1B-328B
HISTOLOGY
CUTTING &
STAINING
1B-328
CLIENT
SERVICES UNIT
1B-311
ABC SYSTEM
1B-311A
GENERAL NOTES FOR WAITING:
1. ALL WALLS TO BE PAINTED
2. ONE VINYL ACCENT WALL
3. CHAIR RAIL THROUGHOUT
4. RUBBER BASE
5. LUXURY VINYL PLANK ON FLOOR
6. SOLID SURFACE ON ALL COUNTER
TOPS
7. HAND RAIL/CRASH RAIL ON ONE WALL
8. GLASS DOUBLE SLIDING DOOR AT
MAIN ENTRY
9. SLIDING DOOR TO LAB BACK ENTRY
GENERAL NOTES FOR BLOOD DRAW AREA:
1. ALL WALLS TO BE PAINTED
2. ALL LAB AREAS PONY WALLS TO
MIMIC DIALYSIS OR ATRIUM LOW
DIVIDING WALLS
2.1. ACROVYN BOTTOM DECORATIVE
3FORM ABOVE
3. RUBBER BASE TO MATCH ACROVYN
4. EXPOXY POURED FLOOR
5. SOLID SURFACE ON ALL COUNTER
TOPS
GENERAL NOTES FOR RESTROOMS:
1. ALL WALLS TO BE TILE
2. FLOOR TILE WITH TILE BASE
3. SOLID SURFACE ON ALL COUNTER
TOPS
4. PARTITIONS TO BE BRADLEY
STANDARD
XXXX
214-857-1021
MARCH 19, 2019
VA MEDICAL CENTER NORTH TEXAS
4500 S. LANCASTER ROAD
DALLAS, TEXAS 75216
CONTACT: DATE: PAGE:PROJECT: 549-19-XXX
NTX REMODEL LAB
CLINICAL ADDITION FIRST FLOOR & BASEMENT
PAGE TITLE:
GENERAL FINISH PLANS
DRAWING SCALE:
5 OF 5SEE DRAWING
| Sheets and Views |
| BYC plans-Model |
| BYC plans-areas of work |
| BYC plans-DEMO |
| BYC plans-DIMENSIONS |
| BYC plans-ELEC DATA |
| BYC plans-FINISHES |