This document provides details on a federal contract opportunity to expand an existing patient parking garage at the Cleveland VA Medical Center. The Department of Veterans Affairs seeks to award a firm-fixed-price contract through design-bid-build procedures to add 132 parking spaces by completing the fourth deck of the garage. The project scope also includes extending vertical transportation and stairs to the new floor, as well as improving lighting and adding a suicide prevention barrier to the existing structure facade. The solicitation will be issued as a Service-Disabled Veteran-Owned Small Business set-aside with offers due by the date specified. The period of performance is approximately 280 calendar days from notice to proceed. Specifications and drawings will be attached to the solicitation posted on FBO. The magnitude of construction is estimated between $2 million and $5 million.
36E77619B0020 0003 S-300_-_CONCRETE_DETAILS.pdf
View the file
Other files
Show 40 more
Latest 50 of 66 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOTE:
1.DETAIL APPLIES TO ALL CONC WALLS NOT INDICATED TO BE SHEAR WALLS
2. LOCATE CONSTRUCTION JOINTS AT LEAST 3' FROM WALL CORNERS & INTERSECTIONS
3. SEE S-001 FOR TENSION LAP SPLICE SCHEDULE.
T E
N S
IO
N S
P
LI
C E
C
LA
S S
B
HAIRPIN DOWLS TO MATCH SIZE &
SPACING OF LARGER HORIZ BAR
12" MIN
STD HK
CLEAN AND ROUGHEN
SURFACE TYPICAL
CONT HORIZ BARS
HOOK HORIZ BARS OR PROVIDE DOWELS
AT SAME SIZE & SPACING
12" MIN
STD HK
TENSION SPLICE
CLASS B
NOTE:
1. SEE S-001 FOR TENSION LAP SPLICE SCHEDULE.
PLACE HORIZ REINF IN OUTER
LAYER
STD HOOK
4 CONT VERTS
MATCH LARGEST SIZE OF INTERSECTION
WALLS, UNO
CLASS B TENSION SPLICE
#4 TIES @ 12"
NOTE:
1. SEE S-001 FOR TENSION LAP SPLICE SCHEDULE.
HAIRPIN DOWELS TO
MATCH SIZE & SPACING OF
LARGER HORIZ BAR
VERT COLUMN REINF, SEE SCHEDULE,
TIES NOT SHOWN FOR CLARITY
3#4 CONT VERTS
T E
N S
IO
N
S P
LI
C
E
C
LA
S S
B
SEE ELEVATIONS
THICKNESS
24 BAR DIA, TYP 4 CONT VERTS, MATCH LARGEST SIZE OF
INTERSECTION WALLS, UNO
#4 @ 12" TIES
SHEAR WALL REINF, SEE ELEVATIONS.
NOTE:
1. SEE S-001 FOR TENSION LAP SPLICE SCHEDULE.
S-300
S-300
2 #6 TRIMMER
BARS EACH CORNER
TYP WALL REINF,
SEE WALL ELEVATIONS
VERTICAL TRIMMER BARS SHALL EXTEND A
MINIMUMOF 48 BAR DIA. PAST THE
OPENING AND SHALL EXTENDFULL HEIGHT
WHERE POSSIBLE. DOWELS OF SAMESIZE
AND NUMBER AS TRIMMER BARS SHALL
BEPROVIDED AT LOCATIONS WHERE
TRIMMER BARS CANNOT EXTEND 48 BAR
DIA. PAST THE OPENING DUE TO PROXIMITY
OF HOLE TO CONSTRUCTION JOINT DOWELS
SHALL BE EMBEDDED 48 BAR DIA. INTO
ANCHORING CONSTRUCTION AND SHALL
LAP 48 BAR DIA. WITH TRIMMER BARS.
2-#6 TRIMMER BARS AT TOP,
BOTTOM, AND SIDES OF ALL
OPENINGS IN CONCRETE WALLS
UNLESS OTHERWISE DETAILED
(SEE WALL ELEVATIONS)
EXTEND HORIZONTAL TRIMMER BAR
48 BAR DIA. OR 2'-6" MIN. BEYOND SIDES
OF OPENING OR AS FAR AS POSSIBLE
AND HOOK IN THE PLANE OF THE WALLS
MIN.
1 1/2" CLR.
2' -
2' -
HORIZONTAL TRIMMER
BARS AT OPNEINGS
VERTICAL REINF.
PROVIDE HAIRPIN
DOWELS TO MATCH SIZE
AND SPACING OF
LARGER HORIZ BAR
VERTICAL REINF.
TYPICAL HORIZ REINF
B A
R D
IA
B
A R
D
IA
TYPICAL HORIZONTAL REINF.
VERTICAL TRIMMER BARSTYPICAL VERTICAL REINF.
PROVIDE HAIRPIN DOWELS
TO MATCH SIZE AND
SPACING OF LARGER HORIZ
BAR
CONSTRUCTION JOINT AT FINISH
FLOOR ELEVATION AND AT TOP
OF FOUNDATION
TYPICAL VERTICAL REINF.
S T
A G
G E
R
M
IN
O R
B A
R D
IA
M
IN
LA
P
O R
B A
R D
IA
M
IN
LA
P
*HORIZONTAL REINFORCEMENT
NOT SHOWN FOR CLARITY
3/8" FORM JOINT FILLED WITH
SEALANT EACH FACE
WATERSTOP
1 1/2"
T /3
T /3
T /3
T
TENSION SPLICE
CLASS B
BOND BREAK
TAPE
7#7T
T
12#7T 12#7T
20#7T 20#7T7#7T
16#6T12#6T 16#6T
12#6T 16#6T 16#6T
T
T
T
T
T
T
T
T
T
T
T
4#6B 4#6B 4#6B
4#6B 4#6B 4#6B
B
B
B
B
"E
C
O
LU
M N
S P
A C
IN
G
"C" - COLUMN SPACING
SIZE OF BARS
DENOTES DIRECTION OF BARS
SPACED EQUALLY OVER STRIP
L1 = SHORTER OF "A" & "D"
L2 = SHORTER OF "B" & "D"
L3 = SHORTER OF "A" & "E"
QUANTITY OF BARS 16 #4 T
POSITION (TOP, BOTTOM OR TIE
FORCE)
SPANDREL BEAM
OR WALL
SEE 12/S-300 FOR
BAR LENGTHS
STRIP
1/4 L1
COLUMN MIDDLE STRIP
STRIP
1/4 L1
COLUMN
STRIP
1/4 L2
COLUMN MIDDLE STRIP
STRIP
1/4 L2
COLUMN
"A" - COLUMN SPACING "B" - COLUMN SPACING
"D
C
O
LU
M N
S P
A C
IN
G
S T
R
IP
/4
L
C O
LU
M
N
S T
R
IP
/4
L
C O
LU
M
N M
ID
D
LE
S
T R
IP
S T
R
IP
/4
L
C O
LU
M
N
CONTINUOUS DROP PANEL. ADDED BOTTOM BARS
ARE TO BE PLACED IN BOTTOM OF DROP PANEL.
TF = TIE FORCE BARS
T = TOP BARS
B = BOTTOM BARS IN ADDITION TO
BOTTOM MAT CALLED OUT ON PLAN
STANDARD 90° OR
180° HOOK
USE HORIZONTAL EXTENSION
WHERE POSSIBLE
"B" BARS SEE NOTE
"T" BARS "T" BARS
NOTES:
"B" BARS SEE
NOTE 2
"T" BARS
1. L = LA or LB, WHICHEVER IS GREATER.
2. SEE PLAN FOR TYPICAL CONTINUOUS BOTTOM REINFORCING MAT.
ADDED BARS SHOWN ON PLAN ARE DETAILED IN THIS DIAGRAM.
3. ALL MILD REINFORCEMENT IN LOCATED IN SLAB SHALL BE EPOXY COATED.
/4
C
LR
LENGTH
DEVELOPMENT
1 1/2" CLR.
0.22 LA 0.22 L
/4
C
LR
0.22 L
(GREATER)
0.22 LB OR 1.0 LC
/4
C
LR
CLEAR SPAN LA COL. WIDTH CLEAR SPAN LB COL. WIDTH CLEAR SPAN LC
/4
C
LR
MIN
6"
0.15 LA 0.15 LB
/4
C
LR
/4
C
LR
0.15 LA 0.15 LB
END PANEL "A" INTERIOR PANEL "B" CANTILEVER PANEL "C"
SQUARE, ROUND OR
RECTANGULAR OPENING
(3'-0" MAX. DIMENSION)
SLAB REINFORCING
NOTES:
1. ALL TOP AND BOTTOM BARS INTERRUPTED BY THE OPENING SHALL BE REPLACED WITH ADDITIONAL REINFORCING EQUAL TO
THAT INTERRUPTED. PLACE HALF OF THE ADDITIONAL REINFORCING ON EACH SIDE OF OF THE OPENING AND EXTEND IT 3'-0"
BEYOND OPENING. PROVIDE STANDARD HOOK IN BARS AT EDGE OF SLAB WHERE 3'-0" EXTENSION IS NOT POSSIBLE.
2. BOXED OUT OPENINGS, RECESSED BOXES AND PIPE SLEEVE CLUSTERS SHALL BE TREATED AS SLAB OPENINGS.
3. OPENINGS LESS THAN 1'-0" NEED NO SPECIAL REINFORCING.
4. CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF ANY OPENING GREATER THAN 1'-0" WHICH IS NOT SHOWN ON THE
STRUCTURAL DOCUMENTS.
2#5 AT MID-DEPTH
OF SLAB
ADDED REINFORCING EQUAL TO HALF
THE REINFORCING INTERRUPTED
3"
1 1 /2
TYP
2' -
TYP
2' -
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseArchitect/Engineer of Record StampConsultant
321 4 5 6 7 8 9 10
Sprinkler Status
PVE ENGINEERING, LLC.
Waterfront Corporate Park III, Suite 101
2000 Georgetowne Drive, Sewickley, PA 15143
Phone: 724-444-1100
Email: info@pve-llc.com
AE Works, LTD.
209 Sandusky Street
Pittsburgh, PA 15212
Phone: 412-287-7333 www.ae-works.com
S-300
CONCRETE DETAILS EXPAND PATIENT PARKING
GARAGE
10701 EAST BOULEVARD, CLEVELAND, OH 44106
161651
05/24/2019 Checker Author
100% BID SET
N.T.S.
REINFORCING AT NON-SHEAR WALL CORNERS
N.T.S
REINFORCING AT CONCRETE WALL CORNERS
N.T.S.
REINFORCING AT CONCRETE WALL TERMINATION
N.T.S.
CONCRETE WALL INTERSECTION DETAIL
N.T.S.
TYPICAL SHEAR WALL OPENING
N.T.S.
REINFORCING AT CONCRETE WALL OPENINGS
N.T.S.
REINFORCING AT SIDES OF CONCRETE WALL OPENINGS
N.T.S.
REINFORCING DETAIL AT SHEAR WALL CONSTRUCTION JOINTS
N.T.S.
TYPICAL WALL CONSTRUCTION JOINT DETAIL
N.T.S
TWO-WAY FLAT SLAB NOTATION
N.T.S
TWO-WAY FLAT SLAB - MIDDLE STRIP BAR BENDING AND PLACING
N.T.S
REINFORCING AT FLOOR SLAB OPENING (3'-0" OPENING MAXIMUM)
# Revisions Date
1 Addendum for Solilcitation 11/22/2019
| Sheets |
| S-300 - CONCRETE DETAILS |