36C78619R0067-003.pdf
PDF 21 MB Posted
- Attached to
- 36C786-19? C? C-0151 | Knoxville NC; Construct New Admin/Maint | Project No. 855-014 | C&C Contractors, Inc.
- Solicitation number
- 36C78619R0067
About this file
36C78619R0067 190502 Knoxville 855-014 Bid Drawings Final.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C78619C0151-000.docx | DOCX document | |
| 36C78619R0067-0002000.docx | DOCX document | |
| 36C78619R0067-0001000.docx | DOCX document | |
| 36C78619R0067-001.docx | DOCX document | |
| 36C78619R0067-005.pdf | ||
| 36C78619R0067-006.pdf | ||
| 36C78619R0067-004.pdf | ||
| 36C78619R0067-002.pdf | ||
| 36C78619R0067-000.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GI001
COVER SHEET
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
PROJECT NUMBER: 855CM3014
BID DOCUMENTS
DEPARTMENT OF
VETERANS AFFAIRS
KNOXVILLE, TENNESSEE
DRAWING INDEX
NO. DRAWING DRAWING TITLE
KNOXVILLE NATIONAL CEMETERY
1. GI001 COVER SHEET
2. GI002 GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS
CIVIL
3. GI100 CONSTRUCTION SEQUENCING PLAN
4. VL101 EXISTING CONDITIONS PLAN
5. BI100 SUBSURFACE BORING LOCATION PLAN & BOREHOLE LOGS
6. GC101 EROSION AND SEDIMENT CONTROL PLAN
7. GC500 EROSION AND SEDIMENT CONTROL NOTES AND DETAILS
8. CD101 SITE DEMOLITION PLAN
9. CS101 SITE LAYOUT & UTILITY PLAN
10. CG101 GRADING AND DRAINAGE PLAN
11. BK201 SITE RETAINING WALL PLAN AND PROFILES
12. DT500 SITE DETAILS
LANDSCAPE
13. LS101 PLANTING PLAN
ARCHITECTURAL
14. AE001 CODE AND LIFE SAFETY
15. AE002 ADA REQUIREMENTS & INTERIOR MOUNTING HEIGHTS
16. AE003 PERSPECTIVES
17. AD001 DEMOLITION PLAN
18. AE101 FLOOR PLAN
19. AE102 ROOF PLAN
20. AE105 REFLECTED CEILING PLAN
21. AE106 FINISH PLAN
22. AE201 BUILDING ELEVATIONS
23. AE202 BUILDING ELEVATIONS
24. AE301 BUILDING SECTIONS
25. AE311 WALL SECTIONS
26. AE312 WALL SECTIONS
27. AE401 ENLARGED INTERIOR PLANS & ELEVATIONS
28. AE501 EXTERIOR DETAILS
29. AE502 EXTERIOR DETAILS
30. AE503 EXTERIOR DETAILS
31. AE601 PARTITION TYPES, DOOR & FRAME DETAILS & SCHEDULE
PLUMBING
32. PL000 PLUMBING NOTES & SYMBOLS
33. PL101 PLUMBING FLOOR PLAN
34. PL501 PLUMBING SCHEDULES & DETAILS
35. PL701 PLUMBING RISERS
MECHANICAL
36. MH000 MECHANICAL NOTES & SYMBOLS
37. MH101 MECHANICAL FLOOR PLAN
38. MH501 MECHANICAL DETAILS
39. MH601 MECHANICAL SCHEDULES
ELECTRICAL
40. EE000 ELECTRICAL SYMBOLS & NOTES
41. ED001 ELECTRICAL DEMOLITION PLAN
42. EL101 ELECTRICAL LIGHTING PLAN
43. EP201 ELECTRICAL POWER PLAN
44. EY301 ELECTRICAL SYSTEMS PLAN
45. EE400 ELECTRICAL DETAILS & SCHEDULES
STRUCTURAL
46. S-001 STRUCTURAL GENERAL NOTES & ABBREVIATIONS
47. S-101 STRUCTURAL FOUNDATION PLAN
48. S-102 STRUCTURAL SLAB FRAMING PLAN
49. S-103 STRUCTURAL ROOF FRAMING PLAN
50. S-201 FOUNDATION SECTIONS AND DETAILS
51. S-202 FOUNDATION SECTIONS AND DETAILS
52. S-301 ROOF FRAMING SECTIONS AND DETAILS
53. S-401 TYPICAL DETAILS & SCHEDULES
P L A N N I N G A R C H I T E C T U R E E N G I N E E R I N G I N T E R I O R S
EST. 1915
6110 EXECUTIVE BOULEVARD
SUITE 440
PH. 202-299-0530
ROCKVILLE, MD 20852
OCMI, INC.
WWW.OCMI.COM
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
APRIL 12, 2019 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTS
5 ALFRED CIRCLE
BEDFORD, MA 01730-2318
WWW.MABBETT.COM
PH. 781-275-6050
MABBETT & ASSOCIATES, INC.
1200 NINETEENTH STREET
SUITE 220
PH. 202-861-4600
WASHINGTON, DC 20036
LEO A DALY.
WWW.LEOADALY.COM
1250 23RD STREET, NW
WASHINGTON, DC 20037
WWW.LOUISBERGER.COM
PH. 202-331-7775
LOUIS BERGER
GI002
GENERAL NOTES, SYMBOLS, AND
ABBREVIATIONS
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
APRIL 12, 2019 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTS
GI100
CONSTRUCTION SEQUENCING PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
APRIL 12, 2019 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
VL101
EXISTING CONDITIONS PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
APRIL 12, 2019 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BI100
SUBSURFACE BORING LOCATION
PLAN & BOREHOLE LOGS
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
APRIL 12, 2019 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTS
LEGEND:
NOTES:
GC101
EROSION AND SEDIMENT CONTROL
PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
APRIL 12, 2019 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTS
NOTES:
EROSION AND
SEDIMENT CONTROL LEGEND:
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
APRIL 12, 2019 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTS
GC500
EROSION AND SEDIMENT CONTROL
NOTES AND DETAILS
CD101
SITE DEMOLITION PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
APRIL 12, 2019 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTS
LEGEND:
NOTES:
DEMOLITION KEYNOTES:
CS101
SITE LAYOUT AND UTILITY PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
APRIL 12, 2019 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTS
GRAPHIC LEGEND:
CG101
GRADING AND DRAINAGE PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
APRIL 12, 2019 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTS
LEGEND:
GRADING NOTES:
BK201
SITE RETAINING WALL PLAN AND
PROFILES
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
APRIL 12, 2019 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
APRIL 12, 2019 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTS
DT500
SITE DETAILS
LS101
PLANTING PLAN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
APRIL 12, 2019 JPG MAC
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTS
LEGEND:
GROUNDCOVER / PERENNIAL PLANTING DETAIL
SHRUB PLANTING DETAIL
DECIDUOUS TREE PLANTING DETAIL
Key Botanical Name Common Name Condition Size (Min.) Quantity Special Characteristics CR Cornus 'Rutgan' Stellar Pink Stellar Pink Dogwood Balled & Burlapped 5' Height 1
Key Botanical Name Common Name Condition Size (Min.) Quantity Special Characteristics BS Buxus sinica var. insularis ' Wintergreen' Wintergreen Boxwood Balled & Burlapped 2' Height 35 Hedge
Key Botanical Name Common Name Condition Size (Min.) Quantity Special Characteristics LM Liriope muscari 'Majestic' Majestic Lilyturf #SP4 Container 18
Grasses, Groundcovers & Perennials
Plant Schedule Trees
Shrubs
OCCUPANCY
S-2
OCCUPANCY
S-2
OCCUPANCY
B
OCCUPANCY
B
377 SF
57 SF
61 SF
252 SF
E
X
I
T
E
X
I
T
F
E
OCCUPANCY
B
STORAGE
ADMIN
MAINTENANCE
RESTROOM
COMMITTAL
SHELTER
E01
STORAGE
CLOSET
E02
DF
OCCUPANCY
B
9 SF
JANITOR'S
CLOSET
03B
5'-4"
8'-11 5/8"
4'-5 1/4"
12'-0"RAMP DN
UP
OCCUPANCY
B
EXIT A
EGRESS PATH WITH NAME, SEGMENT LENGTH, AND
DIRECTION INDICATED
EXIT INDICATOR WITH NAME OF EXIT AND EXIT CAPACITY
IBC OCCUPANCY GROUP
PATH A
FIRE EXTINGUSHERFE
CODE ANALYSIS LEGEND
2-HR FIRE RATED PARTITION
(UL DESIGN NO. U906)
PROJECT DESCRIPTION:
PROGRAM / USE
- BUSINESS, GROUP B OCCUPANCY
- STORAGE , GROUP S-2 OCCUPANCY
NUMBER OF STORIES: 1
GROSS SQUARE FOOTAGE AT ADMIN/MAINTENANCE BUILDING: 1049
FIRE PROTECTION: NON-SPRINKLERED BUILDING
AUTHORITY HAVING JURISDICTION
CITY OF KNOXVILLE - BUILDING INSPECTIONS AND PLANS REVIEW DEPARTMENT
PRIMARY APPLICABLE CODES AND REGULATIONS
CITY OF KNOXVILLE ZONING ORDINANCE (WITH AMENDMENTS) ADOPTED BY CITY ORDINANCE 3369 (AVAILABLE ONLINE AT
CITY'S CODE OF ORDINANCES)
2009 ICC / ANSI A117.1
2012 INTERNATIONAL BUILDING CODE AS ADOPTED
2011 EDITION OF THE NATIONAL ELECTRICAL CODE AS ADOPTED
2012 EDITION OF THE INTERNATIONAL MECHANICAL CODE AS ADOPTED
2012 EDITION OF THE INTERNATIONAL PLUMBING CODE
KNOXVILLE CODE OF ORDINANCES: CHAPTER 6 BUILDINGS AND BUILDING REGULATIONS, ARTICLE I, SECTION 6-5. FIRE
DISTRICT
CODE ANALYSIS
BUILDING DATA
USE GROUP (2012 IBC, CHAPTER 3)
CONSTRUCTION TYPE (2012 IBC TABLE 503)
NUMBER OF STORIES ABOVE GRADE
HIGH RISE (Y/N)
COVERED MALL (Y/N)
FULLY SPRINKLERED (Y/N)
FULLY MONITORED (Y/N)
GROSS SQUARE FEET OF BUILDING
FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) 2012 IBC TABLE 601)
STRUCTURAL FRAME
STRUCTURAL FRAME WHERE SUPPORTING A ROOF ONLY
BEARING WALLS - EXTERIOR
INTERIOR BEARING WALLS WHERE SUPPORTING A ROOF ONLY
NON-BEARING WALLS - EXTERIOR
NON BEARING WALLS - INTERIOR
FLOOR CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOISTS
ROOF CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOISTS
SHAFT AND ELEVATOR HOISTWAYS (UNDER 4 STORIES)
CONNECTING 4 STORIES OR MORE
VERTICAL EXIT ENCLOSURES (2012 IBC, SECTION 1022.2)
HORIZONTAL EXIT ENCLOSURES(2012 IBC, SECTION 707.3.10)
EXIT ACCESS CORRIDORS (2012 IBC, TABLE 1018.1)
DESIGN INCLUDES PENETRATIONS THROUGH FIRE-RESISTIVE RATED ASSEMBLIES. ALL PENETRATIONS ARE TO BE SEALED WITH FIRE-
RESISTANCE RATED MATERIALS INSTALLED AS PRESCRIBED BY NATIONAL TESTING SERVICES AND AS OUTLINED IN ASTM E119; ALL
FIRESAFING AND FIREPROOFING ARE TO BE UL LISTED ASSEMBLIES, WITH SPECIFIC PRODUCTS AND UL ASSEMBLY #S AND
COMPLIANCE TO BE SUBMITTED FOR APPROVAL PRIOR TO USE IN THE WORK.
OPENING PROTECTIVE RATINGS (HOURS) (2012 IBC TABLE 716.5)
FIRE WALLS AND FIRE BARRIERS GREATER THAN 1 HOUR
1 HOUR FIRE WALLS & FIRE PARTITIONS - VERT OPENINGS OR EXIT ENCLOSURES
1 HOUR FIRE WALLS & FIRE PARTITIONS - NON-VERTICAL OPENINGS
1 HOUR FIRE PARTITIONS - CORRIDOR WALLS - MINIMUM FIRE DOOR ASSEMBLY
PROVIDED
REQUIRED
N/A
N/A
N/A
REQUIRED
OPENING
PROTECTIVE
RATING (HR)
1-1/2
3/4
1/3
PROVIDED
OPENING
PROTECTIVE
RATING (HR)
1-1/2
3/4
3/4 OR 1 1/2
(SEE DOOR SCHEDULE)
REQUIRED
ASSEMBLY
RATING (HR)
INTERIOR WALL AND CEILING FINISH FLAMESPREAD REQUIREMENTS (2012 IBC, TABLE 803.9)
INTERIOR EXIT STAIRWAYS, INTERIOR EXIT RAMPS AND EXIT PASSAGEWAYS
CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND EXIT ACCESS RAMPS
ROOMS AND ENCLOSED SPACES
(SEE 2012 IBC, TABLE 803.9 NOTES FOR ADDITIONAL REQUIREMENTS)
GROUP B
B
C
C
GROUP S
C
C
C
FIRE SUPPRESSION AND FIRE ALARM SYSTEMS
NO AUTOMATIC FIRE SUPPRESSION (SPRINKLERS). PROPOSED FIRE ALARM SYSTEM CONSISTS OF UNMONITORED FIRE ALARM PULL
STATIONS.
PORTABLE FIRE EXTINGUISHERS HAVE BEEN PROVIDED WITHIN THE SCOPE OF WORK AREA AS REQUIRED AND LOCATED BASED ON
THE FOLLOWING: ONE PER EVERY 3,000SF OR FRACTION (MIN) MAXIMUM WALKING DISTANCE TO A FIRE EXTINGUISHER NOT TO
EXCEED 75', IN COMPLIANCE WITH NFPA 10.
PORTABLE FIRE EXTINGUISHERS: (1) DRY CHEM (ABC) 10 LBS.
EXIT REQUIREMENTS (FEET) (NON-SPRINKLERED BUILDING)
COMMON PATH OF TRAVEL (2012 IBC, TABLE 1014.3)
DEAD END CORRIDOR (2012 IBC, SECTION 1018.4)
EXIT ACCESS TRAVEL DISTANCE (2012 IBC, TABLE 1016.2)
SEE EGRESS/OCCUPANCY DIAGRAMS. PER IBC 2012 IBC, TABLE 1015.1
ONLY 1 EXIT IS ALLOWED FROM BOTH B AND S OCCUPANCIES.
NOTE BOTH EXITS ARE DIRECTLY TO THE EXTERIOR
PROVIDED
GROUP B/S-2
40'-10"
N/A
40'-10"
MAXIMUM
GROUP B/S-2
100'-0"
20'-0"
200'-0"
EXIT REMOTENESS (2012 IBC, SECTION 1015.2.1)
> 1/2 DIAGONAL
EGRESS CAPACITY
EGRESS CAPACITY REMAINS UNCHANGED
STAIRWAYS (2012 IBC, SECTION 1005.3.1)
OTHER EGRESS COMPONENTS (2012 IBC, SECTION 1005.3.2)
SEE EGRESS/OCCUPANCY DIAGRAMS FOR NUMBER OF EXITS (2012 IBC, SECTION 1018)
N/A
0.2 INCH
B, S-2
IIB
N
N
N
Y
1,049
1.
NOTES
FOR QUANTITY, LOCATION AND TYPE OF EMERGENCY LIGHT FIXTURES, STROBES, SPEAKERS AND PULL STATIONS SEE
ELECTRICAL DRAWINGS.
REQUIRED PLUMBING FIXTURES (2012 IBC, TABLE 2902.1)
WATER CLOSETS
LAVATORIES
DRINKING FOUNTAINS
SERVICE SINKS
REQUIRED FOR
GROUP B
OCCUPANTS
1 per 25
REQUIRED FOR
GROUP A-3
TOTAL
PROVIDED
TOTAL
PROVIDED
REQUIRED FOR
GROUP S-2
REQUIRED FOR
GROUP B
OCCUPANCY CLASSIFICATION
MIXED USE , SEPARATED OCCUPANCIES, UNSPRINKLERED - 2HR SEPARATION REQUIRED BETWEEN OCCUPANCIES PER IBC TABLE 508.4
MEANS OF EGRESS
SEE PLANS
ROOM NO. ROOM NAME USE
GROUP
SF OCCUPANT
LOAD
FACTOR
01 MAINTENANCE S-2
PERSONS
B
377 300 GROSS
02 STORAGE S-2 57 300 GROSS
0.6103 TOILET B 61
04 ADMIN B 252 2.52
TOTAL
100 GROSS
1.44
100 GROSS
TOTAL PERSONS
PERSONS
S-2
0.19
1.25
3.22
1 per 40
OCCUPANTS OCCUPANTS
1 per 100
1 per 100
1 per 100 1 per 100
PER IBC 2012 SECTION 2902.2 EXCEPTION 2. SEPARATE FACILITIES ARE NOT REQUIRED DUE TO OCCUPANT
LOAD OF 15 OR LESS
BUILDING CODE ANALYSIS
THE SITE IS BEING DEVELOPED TO REPLACE AN EXISTING ADMINISTRATION / MAINTENANCE BUILDING WITH A NEW ADMINISTRATION /
MAINTENANCE BUILDING AND TO RECONFIGURE AN EXISTING MAINTEANCE YARD. THE SCOPE ALSO INCLUDES ADDITION OF A COMMITTAL
SHELTER AND MASTER PLANNING FOR A FUTURE COLUMBARIUM. TWO ADA PARKING SPACES WILL BE PROVIDED FOR THE NEW FACILITIES.
PER IBC 903.2.10.1. S-2 ENCLOSED PARKING GARAGE IS NOT REQUIRED TO BE SPRINKLER AS THE FIRE AREA OF THE ENCLOSED PARKING GARAGE DOES NOT
EXCEED 12,000 SF
-N/A
-N/A
0.0903B JANITOR'S CLOSET B 9 100 GROSS
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
KNOXVILLE, TENNESSEE
APRIL 12, 2019
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTSLEO A DALY
(202) 861-4600
MABBETT & ASSOCIATES, INC.
(781) 275-6050
OCMI
(202) 299-0530
LOUIS BERGER
(202) 331-7775 53
SCALE: 3/16" = 1'-0"1 FLOOR PLAN - LIFE SAFETY
N
CODE AND LIFE SAFETY
AE001
4'
SCALE: 3/16"=1'-0"
0 2' 4' 6'
1'-3"
MIN CLEAR
2'- 3"
MI
N.
CL
R
KN
EE
S
PA
CE
2'-
MA
X
TO
R
IM
3'- 4"
M
AX
T O
BO
RE
FL
EC
TE
D
SU
RF
AC
E
OF
M
IR
RO
R
VERIFY SIZE WITH
PLANS AND
ELEVATIONS
8" DEEP
MIN
2'-
" M
AX
TO
R
IM
1'-5" MIN
2'-1" MAX
9" M
IN
9" M
IN
SIDE VIEW FRONT VIEW
1'-5" MIN
LAVATORY
PLUMBING LINES
WITHIN HATCHED
AREA REQUIRED
TO BE INSULATED
LINES OF REQUIRED
CLEARANCE
FINISH FLOOR
4'-0" MIN CLR
2'- 5"
M
IN
5"
2'- 3"
MI
N.
CLEAR SPACE
ALLOWABLE FOR
ACCESSIBILITY
MIRROR
2'- 5"
M
IN
5"
LINES OF REQUIRED
CLEARANCE
6" MAX TOE
CLEARANCE
1'-0"
MAX
3'-6" MIN (DESIGN W/ 48")
ICC/ANSI A117.1
1'- 5"
M
IN
1'-
7" M
AX
TO
S
EA
T
1'- 3"
M
IN
T O
4'- 0"
M
AX
A
FF
TO
O
UT
LE
T
OF
D
IS
PE
NS
ER
2'- 9"
M
IN
3'- 0"
M
AX
T O
BA
R
7" MIN - 9" MAX
ICC/ANSI A 117.1
GRAB BAR
1"
SANITARY NAPKIN
DISPOSAL @ WOMEN
OR UNISEX,
SUGGESTED LOCATION
GRAB BAR
2'- 9"
M
IN
3'- 0"
M
AX
T O
BA
R
3'-6" 1'-4" MIN
TO 1'-6" MAX
SANITARY NAPKIN
DISPOSAL @ WOMEN OR
UNISEX, SUGGESTED
LOCATION
1 1/2"
2'-0" MIN. 1'-0" MIN.
3'-0" MAX
3'- 3"
M
IN
3'-
5" M
AX
1'- 6"
M
IN
3'-3" MIN
3'-5" MAX
VERTICAL GRAB BAR
TO COMPLY W/ ICC/ANSI A117.1
TOILET PAPER
DISPENSER
4'-6"
3'- 3"
M
IN
3'-
5" M
AX
1'- 6"
M
IN
SIDE WALL REAR WALL
VERTICAL GRAB BAR
TO COMPLY W/ ICC/ANSI A117.1
3'-0"
4'- 0"
M
IN
2'-6" MIN
1'- 5"
M
IN
1'- 7"
M
AX
SINK
CLEAR FLOOR
SPACE
4'- 0"
M
IN
2'-6" MIN 3'-0" IF ALCOVE
GREATER THAN 24" DEEP
URINAL
CLEAR FLOOR SPACE
4'- 0"
M
IN
2'-6" MIN
5'-0"
4'- 8"
W
AL
L H
UN
G 4'-
" F
LO
OR
M
OU
T.
1'-4" MIN TO
1'-6" MAX
1'- 5"
M
IN
1'- 7"
M
AX
WATER CLOSET
SINK
CLEAR FLOOR
SPACE
5'-0"
4'- 8"
W
AL
L H
UN
G 4'-
" F
LO
OR
M
OU
NT
1'-4" MIN TO
1'-6" MAX
4'-0" MIN
2'- 6"
M
IN
1'-7" MAX
WATER CLOSET
SINK
CLEAR FLOOR
SPACE
CLEARANCE AT WATER CLOSET
CLEARANCE AT WATER CLOSET
CLEARANCE AT SINK CLEARANCE AT URINAL
4'-6"
2'-
VA - RELATIONSHIP OF FIXTURES AND CLEARANCES
1'- 6"
2'-2"
6'-0"
3'- 0"
2'-
UP-SWINGING
GRAB BARCLEAR FLOOR
SPACES
WATER CLOSET
SINK
4'- 0"
M
IN
2'-6" MIN
GRAB BAR
3'- 0"
M
AX
TO
S
PO
UT
2'-6" MIN
CLR FLOOR SPACE
2'- 3"
T O
BO
TT
OM
OF
LE
AD
IN
G
ED
GE
2'-0" MIN
CLR TO SPOUT
4'-0" MIN
WIDTH OF ALCOVE
FACE OF ADJACENT WALL
ADA
COMPLIANT
EWC
STANDARD
EWC
APRON
2'-
3'- 2"
M
IN
3'- 7"
M
AX
9" M
IN
6" MAX 8" MIN
9" M
IN
2'- 3"
T O
BO
TT
OM
OF
LE
AD
IN
G
ED
GE
1'-3" MIN. 5" MAX.
2'-0" MAX
DEPTH OF ALCOVE
3'- 0"
M
AX
T O
SP
OU
T
EDGE OF WALL
BEYOND
FRONT VIEW SIDE VIEW
3'-
4" M
AX
TO
O
PE
RA
TI
NG
M
EC
HA
NI
SM
4'- 6"
4'- 0"
GARMENT HOOK SOAP DISH
RECESS
SANITARY NAPKIN
DISPOSAL
(WOMEN'S ONLY)
COMBINATION PAPER TOWEL
DISPENSER / WASTE RECEPTACLE
3'- 4"
DI
SP
EN
SE
R
SL
OT
TOILET SEAT
COVER DISPENSER
3'- 4"
M
AX
TO
B
OT
TO
M
SOAP DISH
2'-
UF
C
GU
ID
EL
IN
E
DIAPER CHANGING
STATION
4'- 0"
TOWEL BAR
4'- 0"
TOWEL PIN
3'- 0"
M
IN
4'- 0"
M
AX
HAND DRYER
2'- 0"
UF
C
GU
ID
EL
IN
E
3'- 4"
M
IN
4'- 0"
M
AX
3'- 4"
A
BO
VE
S
IN
K
TO
T
HE
BO
TT
OM
O F
RE
FL
S
UR
FA
CE
2'-
" M
AX
A
FF
MIRROR TOILET PAPER
DISPENSER
1'- 3"
M
IN
TO
4'
-0 " M
AXVARIES FROM 3'-4"
HEIGHT FOR MAX 6"
DEPTH, TO 4'-0" HEIGHT
FOR MAX 1/2" DEPTH
VARIES FROM 3'-0" HEIGHT
FOR MAX 9" DEPTH, TO
4'-0" HEIGHT FOR MAX 1/2"
DEPTH
CENTER OF OPERATING
MECHANISM
GENERAL NOTES - ACCESSIBILITY
1. REFERENCE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN AND ANSI 11.1 2009
EDITION. THE MORE RESTRICTIVE ONE GOVERNS.
2. ILLUSTRATIONS ARE TYPICAL. REFER TO ARCHITECTURAL PLANS FOR PROJECT
SPECIFIC CONFIGURATION. THIS SHEET DOES NOT REPRESENT THE ENTIRETY OF
THE 2010 ADA CODE REQUIREMENTS.
3. ALL DIMENSIONS ARE TO FINISH FACE OF PARTITION.
4. THE ADA SHEET IS FOR CONTRACTOR'S USE AND THE ADA 2010 STANDARDS
GOVERN.
5. THE CONTRACTOR SHALL BRING ALL DISCREPANCIES BETWEEN THE ADA SHEETS
AND CONSTRUCTION DOCUMENT PLANS, SPECS AND DETAILS TO THE OWNERS
ATTENTION.
6. NOT TO SCALE
5'- 0"
L O F
SI
GN
AG
E
C
1'-0"
L OF SIGNAGEC
SCHEDULED
DOOR AND FRAME
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
KNOXVILLE, TENNESSEE
APRIL 12, 2019
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTSLEO A DALY
(202) 861-4600
MABBETT & ASSOCIATES, INC.
(781) 275-6050
OCMI
(202) 299-0530
LOUIS BERGER
(202) 331-7775 53
ADA REQUIREMENT & INTERIOR
MOUNTING HEIGHTS
AE002
SCALE: 1/2" = 1'-0"1 ACCESSIBLE LAVATORY CLEARANCE
SCALE: 1/2" = 1'-0"2 ACCESSIBLE TOILET CLEARANCE
SCALE: 1/4" = 1'-0"3 CLEAR FLOOR SPACES
SCALE: 1/2" = 1'-0"4 ELECTRIC WATER COOLER (EWC)
SCALE: 1/2" = 1'-0"6 TOILET FIXTURE AND ACCESSORIES
SCALE: 1/2" = 1'-0"5 INTERIOR SIGNAGE LOCATION
Project Title
Location
Issue Date Checked Drawn
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
KNOXVILLE, TENNESSEE
APRIL 12, 2019
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTSLEO A DALY
(202) 861-4600
MABBETT & ASSOCIATES, INC.
(781) 275-6050
OCMI
(202) 299-0530
LOUIS BERGER
(202) 331-7775 53
PERSPECTIVES
AE003
DEMOLITION LEGEND
WALL TO BE DEMOLISHED
DOOR, FRAME & ASSOCIATED HARDWARE TO BE DEMOLISHED
ELEMENT TO BE DEMOLISHED
GENERAL NOTES - DEMOLITION
1. REFER TO SHEET GI002 FOR SYMBOLS AND ABBREVIATIONS.
2. REMOVE ALL EXISTING PARTITIONS AND ROOF STRUCTURE AS INDICATED;
INCLUDING DOORS, FRAMES, GLASS AND RELATED HARDWARE INCLUDING
PLUMBING, ELECTRICAL AND MECHANICAL COMPONENTS AS REQUIRED TO
COMPLETELY REMOVE BUILDING.
3. EXISTING PERIMETER OF EXTERIOR WALLS AND WINDOWS TO BE DEMOLISHED AS
REQUIRED TO COMPLETELY REMOVE BUILDING.
4. REMOVE ALL EXISTING FLOOR SLABS, FOUNDATIONS AND ASSOCIATED FINISHES
5. REMOVE ALL EXISTING MILLWORK, FIXTURES, EQUIPMENT AND APPLIANCES.
6. COORDINATE WITH OWNER REGARDING STORAGE OR DISPOSAL REQUIREMENTS.
7. ALL EXISTING FIRE EXSTINGUISHERS TO BE SALVAGED AND RETURNED TO
OWNER FOR REUSE. ENSURE INTERIM FIRE PROTECTION MEASURES ARE
ACCEPTABLE STATE TO THE FIRE MARSHAL.
8. EXISTING EXIT SIGNS TO BE REMOVED IN AREA OF WORK. COORDINATE WITH
OWNER REGARDING STORAGE OR DISPOSAL REQUIREMENTS. ENSURE INTERIM
EXIT SIGNAGE ARE ACCEPTABLE TO AHJ.
9. CAP AND SEAL ALL PIPING AT ITS SOURCE.
10. CAP OLD RUNOUT CONNECTIONS FROM TERMINAL BOXES.
11. HAZARD MATERIAL - CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY IN THE
EVENT THEY ENCOUNTER MATERIAL THAT THEY SUSPECT MAY CONTAIN
HAZARDOUS CONTAINING MATERIAL SUCH AS, BUT NOT LIMITED TO, ASBESTOS,
LEAD BASED PAINT, PCBS, ETC. REFERENCE PROJECT SPECIFICATION FOR
DEMOLITION AND HAZARDOUS MATERIAL REMOVAL & DISPOSAL REQUIREMENT.
REFER TO PROJECT SPECIFICATION 02 83 33.13 FOR "ASBESTOS AND LEAD PAINT
SURVEY REPORT".
12. ALL EXISTING MECHANICAL PLUMBING DUCTWORK, PIPING, EQUIPMENT AND
ACCESSORIES TO BE DISCONNECTED, ABANDONED, AND PROPERLY DISPOSED.
DN
A
B
C
D
BERNARD AVE
DEMOLITION PLAN
SCALE: 1/4" = 1'-0"1 DEMOLITION PLAN
2'
SCALE : 1/4" = 1'-0"
0 4' 8' N
KEYNOTE LEGEND
KEY DESCRIPTION
1 EXISTING STONE WALL TO REMAIN. CONTRACTOR TO ENSURE THE STONE WALL IS
NOT DAMAGED AS A RESULT OF CONSTRUCTION ACTIVITIES
2 SEE CIVIL FOR SCOPE AND EXTENT OF SITE DEMOLITION
3 DEMO PARTITION, DOOR, DOOR FRAMES, FLOOR SLAB, FLOOR FINISHES, CEILING,
LIGHTING AND ALL ASSOCIATED MATERIALS REQUIRED TO COMPLETELY DEMOLISH
BUILDING. SEE CIVIL FOR SITE RESTORATION AND GRADING
4 DEMO EXTERIOR WALLS, ROOF , ASSOCIATED FRAMING, FINISHES, DOORS AND
WINDOWS REQUIRED TO COMPLETELY DEMOLISH BUILDING. SEE CIVIL FOR SITE
RESTORATION AND GRADING
5 DEMO STEPS, RAILING AND ALL ASSOCIATED HARDWARE
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
KNOXVILLE, TENNESSEE
APRIL 12, 2019
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTSLEO A DALY
(202) 861-4600
MABBETT & ASSOCIATES, INC.
(781) 275-6050
OCMI
(202) 299-0530
LOUIS BERGER
(202) 331-7775 5317
AD001
GENERAL NOTES
1. REFER TO SHEET GI002 FOR SYMBOLS AND ABBREVIATIONS.
2. GC SHALL COORDINATE DOOR LOCATION AT HINGE SIDE TO ALLOW FOR A
90 DEGREE SWING IN THE OPEN POSITION.
3. ALL WALL DIMENSIONS ARE TO FACE OF PARTITION, FACE OF CMU, OR
CENTER OF COLUMN LINES U.O.N.
4. THICKNESS OF THE CONCRETE MASONRY UNITS(CMU) AND LIGHT WEIGHT
MASONRYUNIT(LMU) PARTITIONS ARE ACTUAL.
5. ALL PARTITIONS SHALL EXTEND FROM FLOOR TO UNDERSIDE OF DECK
ABOVE UNLESS NOTED OR SCHEDULED OTHERWISE.
6. ALL PARTITIONS WITH SOUND RATING TO EXTEND TO DECK ABOVE.
FURNISH 4 ¼ POUNDS DENSITY GLASS FIBER INSULATION SHAPED TO FIT
THE VOID ABOVE THE PARTITION WHERE AIR-BORNE SOUND CAN
PENETRATE SPACE.
7. SEE STRUCTURAL DRAWINGS FOR LINTEL AND REINFORCING
REQUIREMENTS FOR WALLS. SEE STRUCTURAL DRAWINGS FOR
MASONRY OPENING REQUIREMENTS FOR LOAD BEARING AND NON-LOAD
BEARING.
8. PROVIDE NECESSARY CONCEALED FIRE RATED WOOD BLOCKING/SHEET
BLOCKING WITHIN PARTITION FRAMING FOR INSTALLATION OF MILLWORK
DOORS, AND TOILET ACCESSORIES ETC AND OTHER ITEMS AS REQUIRED,
WHETHER OR NOT SPECIFICALLY CALLED FOR ON DRAWINGS. EXACT
LOCATION TO BE COORDINATED WITH SCHEDULED ACCESSORIES, AND
FIXTURES.
9. ALL WOOD/BLOCKING USED IN WALL CONSTRUCTION IS TO BE FIRE
RETARDANT-TREATED.
10. PROVIDE DOUBLE METAL STUDS AND BRACING TO UNDERSIDE OF
STRUCTURE AT FREE END OF PARTITION AND ALL DOOR FRAMING.
11. PLANS FOR ALL FIXED FIRE PROTECTION EQUIPMENT SUCH AS FIRE
ALARM SYSTEMS MUST BE SUBMITTED TO, AND APPROVED BY THE FIRE
MARSHALL BEFORE EQUIPMENT INSTALLATION.
12. REFER TO CEILING PLAN FOR CEILING FINISHES.
13. ALL WORK SHALL CONFORM TO APPLIABLE CODES AND GOVERNING
AUTHORITIES.
14. PROVIDE CORNER GUARDS AT ALL PARTITIONS OUTSIDE CORNERS.
15. FIRESAFE AT ALL FLOOR PENETRATIONS OUTISIDE THE RATED SHAFT.
16. ALL INTERIOR WOOD TO BE FRT U.O.N.; ALL EXTERIOR WOOD TO BE PT
U.O.N.; ALL INTERIOR WOOD IN WET AREAS TO BE EXTERIOR GRADE FRT
U.O.N.
17. FURNITURE AND EQUIPMENT IS NOT IN SCOPE OF WORK; FOR REFERENCE
ONLY
KEYNOTE LEGEND
KEY DESCRIPTION
1 CONCRETE SLAB CONTROL JOINT - SEE STRUCTURAL DOCUMENTS
2 DOWNSPOUT AND CONCRETE SPLASH BLOCK
3 CONCRETE SIDEWALK / PAVEMENT- SEE CIVIL DOCUMENTS
4 DRINKING FOUNTAIN - SEE PLUMBING DOCUMENTS
5 WHITEBOARD, NIC. PROVIDE IN-WALL FIRE-RETARDANT TREATED WOOD BLOCKING
6 CONCRETE EQUIPMENT PAD - COORDINATE SIZE WITH MECH EQUIPMENT
7 BRICK MASONRY SCREEN WALL
8 RETAINING WALL - SEE CIVIL
9 ELECTRICAL EQUIPMENT - SEE ELECTRICAL DOCUMENTS
10 CONCRETE SLAB ON GRADE - SEE STRUCTURAL DOCUMENTS
NEW CONSTRUCTION LEGEND
NEW PARTITION
FE
NEW DOOR
FIRE EXTINGUISHER
11 CONCRETE GUTTER - SEE CIVIL DOCUMENTS
1'-10"
1'-3 3/4"
EQ
2'-0" TYP.
4 1/2"
18'-8"
8"
27'-8"
1'-0"
±4'-0"
7" 3'-4" M.O.
3'-0"
ROOF OVERHANG
3'-0"
ROOF OVERHANG
3'-0"
ROOF OVERHANG
3'-0"
ROOF OVERHANG
3'-0"
ROOF OVERHANG
1'-3"
A
C
D
22'-0"
17'-0 1/8"
22'-0"
3'-7 5/8"
12'-8"
EQ
2'-0" TYP.
EQ
2'-6"
2'-6"
12'-0" M .O.
17'-8"
47'-8"
6'-0" M.O.
6'-4"
5'-4" M .O.
4'-8"
6'-0" M .O.
5'-0"
2'-10"
2'-10"
6'-4"
03A
03B
02B
01A
01B
01C
W1 W1
W2
W2
3'-4" M.O.
2'-6 1/4"
E02
20'-4 3/8"
7 5/8"
8'-4 3/8"
7 5/8"
15'-0 1/2"
2'-2 3/4"
6'-4" M.O.
2'-2 3/4"
3'-4" M.O.
1'-6"
1'-6"M.O. 2'-0"
±3'-0"
7'-11 3/4"
1'-0 1/4"
C
C
C
C
M1
M
M1
9'-0"
19'-4"
3'-4"M.O.
1'-6" 1'-6"M.O. 2'-0"
M
EQ
7'-2 3/4"
1'-9 1/4"
7'-11 1/4"
3'-4 7/8"
4'-0 3/4"
M2
AE202
AE202
AE202
AE202
AE201
AE201
AEA301
AE301
2AE301
2AE301
3AE301
3AE301
UP
SLOPE DN 1: 12
T.O.S.
920.67'
T.O.S.
920.67'
T.O.S.
918.67'
T.O. SIDE WALK
~917.3' (REF CIVIL)
T.O.S.
917.5'
FE
T.O.S.
918.67'
T.O.S.
920.67'
T.O.S.
918.67'
STORAGE
ADMIN
MAINTENANCE
JANITOR'S
CLOSET
03B
COMMITTAL
SHELTER
E01
STORAGE
CLOSET
E02
RESTROOM
AE401
3 TREADS @
12" = 3'-0"
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
KNOXVILLE, TENNESSEE
APRIL 12, 2019
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTSLEO A DALY
(202) 861-4600
MABBETT & ASSOCIATES, INC.
(781) 275-6050
OCMI
(202) 299-0530
LOUIS BERGER
(202) 331-7775 53
SCALE: 1/4" = 1'-0"1 FLOOR PLAN
2'
SCALE : 1/4" = 1'-0"
0 4' 8' N
FLOOR PLAN
AE101
KEYNOTE LEGEND
KEY DESCRIPTION
1 METAL SHINGLES ROOF
2 EXHAUST - SEE MECHANICAL DOCUMENTS
3 GUTTER & DOWNSPOUT, TYP.
1. REFER TO SHEET GI002 FOR SYMBOLS AND ABBREVIATIONS
2. SEE FLOOR PLAN FOR BUILDING DIMENSIONS. DO NOT SCALE THE ROOF
PLAN.
3. GC SHALL COORDINATE SIZE OF EQUIPMENT PADS AND CURBS WITH
ACTUAL EQUIPMENT BEING PROVIDED. SIZES INDICATED WITH "±" ARE
APPROXIMATE SUBJECT TO VERIFICATION.
4. EQUIPMENT PADS AND CURBS SHALL BE SIZED ACCORDING TO
EQUIPMENT REQUIREMENTS UNLESS NOTED OTHERWISE.
5. INSTALL ROOFING IN ACCORDANCE WITH MANUFACTURER’S
REQUIREMENTS TO ACHIEVE SPECIFIED WARRANTY. FOLLOW
MANUFACTURER’S STANDARD INSTALLATION DETAILS AND
REQUIREMENTS AT ALL CONDITIONS NOT SPECIFICALLY DETAILED BY
ARCHITECT.
6. VENTS, BOILER STACKS, EXHAUST FANS, TIE-OFFS, ANTENNA SUPPORTS
AND OTHER ITEMS THAT EXTEND ABOVE THE ROOF HEIGHT THAT ARE
VISIBLE FROM GROUND LEVEL SHALL BE PAINTED UNLESS FACTORY
FINISHED OR NOTED OTHERWISE.
7. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION REGARDING ROOFTOP EQUIPMENT AND FOR
PENETRATIONS NOT INDICATED ON THIS DRAWING.
8. CONTRACTOR SHALL ACCOUNT FOR ALL FIELD CONDITIONS THAT COULD
AFFECT DRAINAGE OF ROOF SURFACES (E.G., CAMBER, EXISTING
UNEVENNESS, ETC.) TO ACHIEVE INTENDED DRAINAGE.
9. ALL EXTERIOR STEEL TO BE GALVANIZED AND RECEIVE HIGH
PERFORMANCE COATING U.O.N.
1 3
A
C
D
22'-0"
17'-0 1/8"
22'-0"
3'-7 5/8"
28'-0"
3'-0"
28'-0"
3'-0"
51'-8"
31'-8"
3"/1'-0" SLOPE DN
3"/1'-0" SLOPE DN
3"/1'-0" S
LOPE DN
3"/1'-0" S
LOPE DN
6"/1'-0" S
LOPE DN
6"/1'-0" S
LOPE DN
6"/1'-0" SLOPE DN
6"/1'-0" SLOPE DN
2'-9 5/8"
1'-2"
10"
3'-0"3'-0
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
KNOXVILLE, TENNESSEE
APRIL 12, 2019
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTSLEO A DALY
(202) 861-4600
MABBETT & ASSOCIATES, INC.
(781) 275-6050
OCMI
(202) 299-0530
LOUIS BERGER
(202) 331-7775 53
SCALE: 1/4" = 1'-0"1 ROOF PLAN
2'
SCALE : 1/4" = 1'-0"
0 4' 8' N
ROOF PLAN
AE102
KEY DESCRIPTION
1 SHOP FINISHED METAL ROOF DECK.
2 OVERHEAD COILING DOOR BOX HOUSING
3 CEILING HUNG MECHANICAL EQUIPMENT. SEE MECHANICAL DOCUMENTS
RCP LEGEND
OPEN TO STRUCTURE
EXTERIOR METAL SOFFIT WITH VENT
CEILING HEIGHT
1. REFER TO SHEET GI002 FOR SYMBOLS AND ABBREVIATIONS.
2. UNLESS DIMENSIONED/NOTED OTHERWISE, INDEPENDENT CEILING GRID
WITHIN A ROOM TO BE CENTERED IN THE ROOM AS SHOWN.
3. ALL DOWN LIGHTS TO BE CENTERED WHEN LOCATED IN THE CEILING TILE
TYP.
4. ALL LIGHTING DIMENSIONS ARE TO THE CENTER OF FIXTURES TYP
UNLESS NOTED OTHERWISE.
5. SINGLE LIGHT FIXTURE IN A ROOM TO BE MOUNTED IN THE CENTER OF
CEILING, TYP.
6. ALL EXIT LIGHTS, STROBES AND SPEAKERS, TO BE CENTERED IN THE
CEILING TILE UNLESS DIMENSIONED OTHERWISE. ALL EXIT DEVICES TO BE
CENTERED ON OPENING UNLESS DIMENSIONED OTHERWISE.
7. LIGHTS, FIXTURES, EXIT SIGNS AND OTHER DEVICES SHOWN FOR FIXTURE
LOCATION AND TYPE ONLY. REFER TO ELECTRICAL DRAWINGS FOR
INFORMATION ON SPECIFICATION, POWER REQUIREMENTS, CIRCUITING,
SWITCHING AND EMERGENCY LIGHTING.
8. REFER TO ELECTRICAL DRAWINGS FOR LOCATION AND TYPE OF EXIT
SIGN, STROBE, AND PULLS. REFER TO MECHANICAL DRAWINGS FOR AIR
DIFFUSERS, RETURNS AND TRANSFER DUCTS.
9. ALL VISIBLE SURFACES OF NEW DIFFUSERS AND AIR DEVICES TO BE
MANUFACTURER'S WHITE COLOR U.O.N.
10. UNLESS NOTED OTHERWISE, ALL ACOUSTICAL CEILING TILE AND GRID TO
BE ACT-1. SEE INTERIOR FINISH SCHEDULE FOR SPECIFICATION.
11. ALL EXTERIOR WINDOWS TO RECEIVE WINDOW SHADE.
12. REFER TO ELECTRICAL DOCUMENTS FOR LIGHT FIXTURE SCHEDULE
2' X 2' ACOUSTICAL CEILING TILE
X'-XX"
FIXTURE LEGEND
D4 4" RECESSED SQUARE LED DOWNLIGHT
D4E 4" RECESSED SQUARE LED DOWNLIGHT - EXTERIOR
D6S 6" DIA PENDANT MOUNTED ROUND LED DOWNLIGHT -
EXTERIOR. MOUNT AT 10' AFF
L/TR6 RECESSED LINEAR LED LIGHT
H/HE 4' LINEAR INDUSTRIAL LED LIGHT MOUNT AT 10' AFF
A 2' LINEAR WALL MOUNTED LED LIGHT
ZB EXTERIOR LED WALL PACK
INFRARED HEATER - SEE MECHANICAL DOCUMENTS
SURFACE MOUNTED FAN - SEE MECHANICAL DOCUMENTS
PAINTED STEEL BEAMS AND RAFTERS. SEE STRUCTURAL DOCUMENTS
7'-0"
7'-2"
EQ
EQ
EQ
7'-0"
12'-4"
3'-2"
1'-5"
1'-5"
6'-8"
23'-10"
EQ
EQ
4'-4 3/4"
6'-7 1/8"
13'-2 5/8"
4'-4 5/8"
4'-4 7/8"
A
C
D
22'-0"
17'-0 1/8"
22'-0"
3'-7 5/8"
9'-0"
9'-0"
9'-0"
OPEN TO
STRUCTURE OPEN TO
STRUCTURE
OPEN TO
STRUCTURE
SLOPED
TO
STRUCTURE
HE
H
H
H
HE
H H
D4E
D4E
D4E
D4E
D4E
D4ED4E
D4
TR6
TR6
D4E
A
D6S
D6S
D6S
D6S
D6S
D6S
ZB
ZB
ZB
ZB
ZB
ZB
ZB
7'-2"
4'-9 1/4" 4'-6"
4'-6"
8'-0"
8'-0"
3'-8 1/8"
6'-7 1/4"
6'-7 1/4"
TR6
TR6
4'-6"
4'-2 1/8"
L
3'-1 1/4"
EQ
EQ
EQ
EQ1
EQ1
14'-0"
9'-0"
EQ
EQ
4'-4 3/4"
6'-7 1/8"
EQ
EQ
EQ
EQ
1'-0"
EQ1
EQ1
EQ
EQ
8'-0"
D4
D4 D4
D4
D4
D4
STORAGE
MAINTENANCE
RESTROOM
COMMITTAL
SHELTER
STORAGE
CLOSET
E02
E01
JANITOR'S
CLOSET
03B
ADMIN
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
KNOXVILLE, TENNESSEE
APRIL 12, 2019
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTSLEO A DALY
(202) 861-4600
MABBETT & ASSOCIATES, INC.
(781) 275-6050
OCMI
(202) 299-0530
LOUIS BERGER
(202) 331-7775 53
SCALE: 1/4" = 1'-0"1 REFLECTED CEILING PLAN
2'
SCALE : 1/4" = 1'-0"
0 4' 8' N
REFLECTED CEILING PLAN
AE105
http://www.Architecture4design.com http://www.Architecture4design.com http://www.Architecture4design.com http://www.Architecture4design.com http://www.Architecture4design.com http://www.Architecture4design.com http://www.Architecture4design.com http://www.Architecture4design.com http://www.Architecture4design.com http://www.Architecture4design.com http://www.Architecture4design.com http://www.Architecture4design.com
1. TYPICAL DOOR LOCATION TO THE NEAREST RETURNING PARTITION TO BE
6" MEASURED FROM THE FACE OF PARTITION TO OUTER EDGE OF JAMB
AT HINGE SIDE, ALLOWING THE DOOR FOR A 90 DEGREE SWING, U.O.N.
CONTRACTOR TO COORDINATE DOOR STOP LOCATION WITH PLAN TO
OPEN MINIMUM 90 DEGREES CLEAR, TYP.
2. ALL WALL DIMENSIONS ARE TO FACE OF PARTITION, FACE OF CMU, OR
CENTER OF COLUMN LINES U.O.N.
3. THICKNESS OF THE CONCRETE MASONRY UNITS(CMU) AND LIGHT WEIGHT
MASONRY UNIT (LMU) PARTITIONS ARE NOMINAL UNLESS NOTED
OTHERWISE.
4. ALL PARTITIONS SHALL EXTEND FROM FLOOR TO UNDERSIDE OF DECK
ABOVE UNLESS NOTED OR SCHEDULED OTHERWISE.
5. EXTERNAL CORNER OF CMU AND LMU PARTITION TO BE BULLNOSE, TYP.
6. PROVIDE CONTROL JOINTS ON THE DRYWALL RUNNING MORE
THAN 25’ LONG.CONTROL JOINTS TO BE 25’ O.C.
7. ALL COLUMNS THAT ARE BUTT FACED WITH THE EXTERIOR WALL ON
INTERIOR SPACES SHALL BE TREATED WITH SAME MATERIAL SCHEDULED
AT INTERIOR WALLS UNLESS OTHERWISE SHOWN OR DETAILED.
8. SEE STRUCTURAL DRAWINGS FOR LINTEL AND REINFORCING
REQUIREMENTS FOR WALLS AND FLOOR OPENING. SEE STRUCTURAL
DRAWINGS FOR MASONRY OPENING REQUIREMENTS FOR LOAD BEARING
AND NON-LOAD BEARING.
9. CONTRACTOR TO COORDINATE FLOOR OPENING WITH STRUCTURE.
10. MAINTAIN FIRE SEPARATION RATING AT ALL SLAB PENETRATIONS. ALL
UNUSED OPENINGS IN FLOOR SLAB TO BE FILLED WITH FIRE-STOP.
11. ALL FREESTANDING COLUMNS WITHIN SPACE TO BE LEFT EXPOSED.
12. EXTERIOR FACE BRICK SHALL EXTEND A MINIMUM OF 8” BELOW GRADE.
13. PROVIDE NECESSARY CONCEALED FIRE RATED WOOD BLOCKING/SHEET
BLOCKING WITHIN PARTITION FRAMING FOR INSTALLATION OF MILLWORK
CABINETS, DOORS, INTERIOR WINDOWS, AND TOILET ACCESSORIES ETC
AND OTHER ITEMS AS REQUIRED, WHETHER OR NOT SPECIFICALLY
CALLED FOR ON DRAWINGS. EXACT LOCATION TO BE COORDINATED WITH
SCHEDULED ACCESSORY, CABINET AND FIXTURES.
14. ALL WOOD/BLOCKING USED IN WALL CONSTRUCTION IS TO BE FIRE
RETARDANT-TREATED.
15. PROVIDE DOUBLE METAL STUDS AND BRACING TO UNDERSIDE OF
STRUCTURE AT FREE END OF PARTITION AND ALL DOOR FRAMING.
16. PLANS FOR ALL FIXED FIRE PROTECTION EQUIPMENT SUCH AS
SPRINKLER SYSTEMS AND FIRE ALARM SYSTEMS MUST BE SUBMITTED TO,
AND APPROVED BY, THE FIRE MARSHALL BEFORE EQUIPMENT
INSTALLATION.
17. REFER TO CEILING PLAN FOR CEILING FINISHES.
18. ALL WORK SHALL CONFORM TO APPLICABLE CODES AND GOVERNING
AUTHORITIES.
19. SEE ENLARGED FLOOR PLANS FOR ADDITIONAL INFORMATION.
20. PROVIDE CORNER GUARDS AT ALL PARTITIONS OUTSIDE CORNERS IN
PUBLIC HALLWAYS.
21. FIRE SAFE AT ALL FLOOR PENETRATIONS OUTSIDE THE RATED SHAFT.
22. ALL INTERIOR WOOD TO BE FRT U.O.N.; ALL EXTERIOR WOOD TO BE PT
U.O.N.; ALL INTERIOR WOOD IN WET AREAS TO BE EXTERIOR GRADE FRT
U.O.N.
23. PROVIDE AND INSTALL INTERIOR SIGNAGE ADMIN, RESTROOM, STORAGE
ROOMS AND JANITOR'S CLOSET PER 10 14 05 INTERIOR SIGNAGE. SEE
5/AE002 FOR MOUNTING LOCATION.
24. EXTERIOR METAL RAILINGS TO BE ANODIZED ALUMINUM. FINISH TO
MATCH P-5
KEYNOTE LEGEND
KEY DESCRIPTION
1 SEE CIVIL DOCUMENTS FOR EXTERIOR FINISH AND PATTERNS
2 CORNER GUARD CG-1
3 WINDOW TREATMENT
STORAGE
ADMIN
MAINTENANCE
RESTROOM
COMMITTAL
SHELTER
E01
STORAGE
CLOSET
E02
FLOOR:
BASE:
WALL:
C-1 N/A P-1
FLOOR:
BASE:
WALL:
C-1 N/A P-1
FLOOR:
BASE:
WALL:
T-1 T-2 T-1A
FLOOR:
BASE:
WALL:
VCT-1
RB-1
P-1
FLOOR:
BASE:
WALL:
C-1 N/A P-1
P-4
CEILING: P-1
JANITOR'S CLOSET
03B
FLOOR:
BASE:
WALL:
T-1 T-2 T-1A
INTERIOR MATERIAL FINISH SCHEDULE
FINISH CODE DESCRIPTION MFG STYLE / NUMBER / COLOR REMARKS
P-1 WALL PAINT SHERWIN WILLIAMS EXTRA WHITE/SW 7006
VCT-1 VINYL COMPOSITION TILE JOHNSONITE
T-1 PORCELAIN TILE - FLOOR
APHELION
COLLECTION
EGGSHELL
12" x 12" - PROTOSTAR/HAMILTON, MATTE
AZROCK COLLECTION VCT - V202 SALT & PEPPER
RB-1 WALL BASE JOHNSONITE TRADITIONAL RUBBER WALL BASE, 29 MOON ROCK 4" HIGH
WINDOW TREATMENT
HUNTER DOUGLAS
1" ALUMINUM MINI BLINDS, CL62/065 BRUSHED ALUMINUM TYPICAL AT ALL EXTERIOR WINDOWS
FLAME
SPREAD
SMOKE
DEVELOPMENT
CLASS 1 >0.45 CRF <450
CLASS A <450
T-1A PORCELAIN TILE - WALL
CG-1
CORNER GUARD - SURFACE
MOUNTED
INPRO 150 HIGH IMPACT, 3" PROFILE, 101 DESIGNER WHITE
HEIGHT: FLOOR TO 4' AFF ON ALL OUTSIDE
CORNERS OF INTERIOR SPACES.
CLASS A <450
P-2 EXTERIOR DOOR AND FRAME PAINT SHERWIN WILLIAMS COLOR TO MATCH METAL ROOF PANELS
PTG-1 19 PEARL GRAY, SEAL ALL GROUT
ACT-1 ACOUSTICAL CEILING TILE ARMSTRONG
15/16" BEVELED TEGULAR DUNE TILE WITH 15/16" PRELUDE XL IN
WHITE.
CLASS A <450
SEMI-GLOSS
P-3 INTERIOR DOOR AND FRAME PAINT SHERWIN WILLIAMS EXTRA WHITE/SW 7006
SEMI-GLOSS
P-4 INTERIOR ACCENT WALL PAINT SHERWIN WILLIAMS DUTCH TILE BLUE/SW 0031
EGGSHELL
P-5 EXTERIOR PAINT SHERWIN WILLIAMS COLOR TO MATCH METAL ROOF PANELS
SEMI-GLOSS
QUARTER-TURN PATTERN
PTG-1 19 PEARL GRAY, SEAL ALL GROUT
APHELION
COLLECTION
12" x 12" - PROTOSTAR/HAMILTON, MATTE
C-1 SEALED CONCRETE
T-2 PORCELAIN TILE - WALL BASE PTG-1 19 PEARL GRAY, SEAL ALL GROUT
APHELION
COLLECTION
3" x 12" - PROTOSTAR/HAMILTON, MATTE
WT-1
P-6 EXTERIOR BEAM/RAFTER PAINT SHERWIN WILLIAMS COLOR TO MATCH EXPOSED METAL ROOF DECK
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
KNOXVILLE, TENNESSEE
APRIL 12, 2019
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTSLEO A DALY
(202) 861-4600
MABBETT & ASSOCIATES, INC.
(781) 275-6050
OCMI
(202) 299-0530
LOUIS BERGER
(202) 331-7775 53
SCALE: 1/4" = 1'-0"1 FLOOR FINISH PLAN
2'
SCALE : 1/4" = 1'-0"
0 4' 8' N
FINISH PLAN
AE106
'-0
7'-
8"
'-8
2'- 0"
'-0
5'-
0"
'-0
8'- 8"
'-0
'-0
T.O. ROOF
COMMITTAL SHELTER
EL= 17'-8"
B.O. EAVES
COMMITTAL SHELTER
EL= 10'-0"
T.O.S.
COMMITTAL SHELTER
EL= 0'-0" B = 917.50' CIVIL
T.O. ROOF
ADMIN BLDG
EL= 19'- 0"
B.O. EAVES
ADMIN BLDG
EL= 14'-0"
T.O.S.
ADMIN BLDG
EL= 0'-0" A = 918.67' CIVIL
T.O.S.
MAINTENANCE
EL= 2'-0" (920.67' CIVIL)
W1
1'-0"
RAIL EXTENSION
1'-0"
RAIL EXTENSION
OPEN TO BEYOND
3 1/2"
AE311
AE311
AE501
2'- 0"
'-0
5'-
0"
'-0
'-0
7'-
8"
'-8
2'-8" 2'-1"2'-1"
'-0
3 2 1
T.O. ROOF
ADMIN BLDG
EL= 19'- 0"
B.O. EAVES
ADMIN BLDG
EL= 14'-0"
T.O.S.
ADMIN BLDG
EL= 0'-0"A = 918.67' CIVIL
T.O. ROOF
COMMITTAL SHELTER
EL= 17'-8"
B.O. EAVES
COMMITTAL SHELTER
EL= 10'-0"
T.O.S.
COMMITTAL SHELTER
EL= 0'-0" B = 917.50' CIVIL
T.O.S.
MAINTENANCE
EL= 2'-0" (920.67' CIVIL)
AE311
4 TYP
AE501
KEYNOTE LEGEND
KEY DESCRIPTION
1 HOLLOW METAL DOOR.
2 OVERHEAD COILING DOOR.
3 GRADE - SEE CIVIL DOCUMENTS
4 EXTERIOR LIGHT FIXTURE - SEE RCP AND ELECTRICAL DOCUMENTS
5 METAL SHINGLE ROOFING. RF-1
6 CONCRETE EQUIPMENT PAD - COORDINATE SIZE WITH MECH EQUIPMENT
7 BRICK MASONRY SCREEN WALL WITH OPENING
8 RETAINING WALL - SEE CIVIL DOCUMENTS
9 ANODIZED ALUMINUM GUTTER AND DOWNSPOUT. FINISH: P5
10 EXISTING BOUNDARY WALL - SEE CIVIL DOCUMENTS
11 CAST STONE. ST-1
12 PRECAST SILL/CAP. PC-1
13 FACE BRICK VENEER. FB-1
14 GUARDRAIL - SEE CIVIL DOCUMENTS
15 MECHANICAL LOUVER - SEE MECHANICAL DOCUMENTS
16 BRONZE SERVICE SEAL PLAQUE
17 PAINTED STEEL COLUMN. FINISH: P5
18 SOLDIER COURSE AT HEAD OF WALL
19 THIN BRICK VENEER FB-2
20 KNEE WALL NOT SHOWN FOR CLARITY
21 ANODIZED ALUMINUM RAMP AND STAIR HAND RAILS
22 METAL FASCIA. FINISH: P5
EXTERIOR MATERIAL FINISH SCHEDULE
FINISH CODE DESCRIPTION MFG STYLE / NUMBER / COLOR
FB-1 FACE BRICK BOWERSTON PLANT MOHICAN BLEND NO DENTS MODULAR
RF-1 METAL ROOF SHINGLE
INTERLOCK
PAC-CLAD PETERSEN PAC-750 SOFFIT HALF VENT
SLATE/ DEEP CHARCOAL GREY
PC-1 PRECAST SILL / CAP BORAL CHAMPAGNE
ST-1 CAST STONE BORAL
SCULPTED ASHLAR/SILVER SHORE
MT-1 METAL SOFFIT PANEL
FB-2 THIN BRICK BOWERSTON PLANT MOHICAN BLEND NO DENTS MODULAR
WINDOW SCHEDULE
TAG
SIZE
W1
WIDTH HEIGHT
6'-0" 6'-5" W2 1'-6" 5'-0"
W#
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
KNOXVILLE, TENNESSEE
APRIL 12, 2019
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTSLEO A DALY
(202) 861-4600
MABBETT & ASSOCIATES, INC.
(781) 275-6050
OCMI
(202) 299-0530
LOUIS BERGER
(202) 331-7775 53
2'
SCALE : 1/4" = 1'-0"
0 4' 8'
BUILDING ELEVATIONS
AE201
SCALE: 1/4" = 1'-0"1 ELEVATION
SCALE: 1/4" = 1'-0"2 ELEVATION
2'- 0"
'-0
5'-
0"
'-0
'-0
7'-
8"
'-8
'-0
2'- 4"
5'- 0"
C
D C A
A
T.O. ROOF
ADMIN BLDG
EL= 19'- 0"
B.O. EAVES
ADMIN BLDG
EL= 14'-0"
T.O.S.
ADMIN BLDG
EL= 0'-0" A = 918.67' CIVIL
T.O. ROOF
COMMITTAL SHELTER
EL= 17'-8"
B.O. EAVES
COMMITTAL SHELTER
EL= 10'-0"
T.O.S.
COMMITTAL SHELTER
EL= 0'-0" B = 917.50' CIVIL
W2
7'- 6"
1'-8" TYP.
T.O.S.
MAINTENANCE
EL= 2'-0" (920.67' CIVIL)
EQ EQ
17 TYP
12 TYP
2'- 0"
'-0
5'-
0"
'-0
'-0
7'-
8"
'-8
'-0
2'- 3"
6'- 5"
CA
D
T.O. ROOF
ADMIN BLDG
EL= 19'- 0"
B.O. EAVES
ADMIN BLDG
EL= 14'-0"
T.O.S.
ADMIN BLDG
EL= 0'-0" A = 918.67' CIVIL
T.O. ROOF
COMMITTAL SHELTER
EL= 17'-8"
B.O. EAVES
COMMITTAL SHELTER
EL= 10'-0"
T.O.S.
COMMITTAL SHELTER
EL= 0'-0" B = 917.50' CIVIL
W1
W2
T.O.S.
MAINTENANCE
EL= 2'-0" (920.67' CIVIL)
EQ
EQ
EQ
EQ1 EQ1
EQ EQ
7'- 5"
AE311
AE312
AE312
17 TYP
KEYNOTE LEGEND
KEY DESCRIPTION
1 HOLLOW METAL DOOR.
2 OVERHEAD COILING DOOR.
3 GRADE - SEE CIVIL DOCUMENTS
4 EXTERIOR LIGHT FIXTURE - SEE RCP AND ELECTRICAL DOCUMENTS
5 METAL SHINGLE ROOFING. RF-1
6 CONCRETE EQUIPMENT PAD - COORDINATE SIZE WITH MECH EQUIPMENT
7 BRICK MASONRY SCREEN WALL WITH OPENING
8 RETAINING WALL - SEE CIVIL DOCUMENTS
9 ANODIZED ALUMINUM GUTTER AND DOWNSPOUT. FINISH: P5
10 EXISTING BOUNDARY WALL - SEE CIVIL DOCUMENTS
11 CAST STONE. ST-1
12 PRECAST SILL/CAP. PC-1
13 FACE BRICK VENEER. FB-1
14 GUARDRAIL - SEE CIVIL DOCUMENTS
15 MECHANICAL LOUVER - SEE MECHANICAL DOCUMENTS
16 BRONZE SERVICE SEAL PLAQUE
17 PAINTED STEEL COLUMN. FINISH: P5
18 SOLDIER COURSE AT HEAD OF WALL
19 THIN BRICK VENEER FB-2
20 KNEE WALL NOT SHOWN FOR CLARITY
21 ANODIZED ALUMINUM RAMP AND STAIR HAND RAILS
22 METAL FASCIA. FINISH: P5
EXTERIOR MATERIAL FINISH SCHEDULE
FINISH CODE DESCRIPTION MFG STYLE / NUMBER / COLOR
FB-1 FACE BRICK BOWERSTON PLANT MOHICAN BLEND NO DENTS MODULAR
RF-1 METAL ROOF SHINGLE
INTERLOCK
PAC-CLAD PETERSEN PAC-750 SOFFIT HALF VENT
SLATE/ DEEP CHARCOAL GREY
PC-1 PRECAST SILL / CAP BORAL CHAMPAGNE
ST-1 CAST STONE BORAL
SCULPTED ASHLAR/SILVER SHORE
MT-1 METAL SOFFIT PANEL
FB-2 THIN BRICK BOWERSTON PLANT MOHICAN BLEND NO DENTS MODULAR
WINDOW SCHEDULE
TAG
SIZE
W1
WIDTH HEIGHT
6'-0" 6'-5" W2 1'-6" 5'-0"
W#
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
KNOXVILLE, TENNESSEE
APRIL 12, 2019
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of
Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
FOR CONSTRUCTION
KNOXVILLE NATIONAL CEMETERY
DEMO ADMIN/MAINT - CONSTRUCT
ADMIN/MAINT & COMMITTAL SHELTER
855CM3014
BID DOCUMENTSLEO A DALY
(202) 861-4600
MABBETT & ASSOCIATES, INC.
(781) 275-6050
OCMI
(202) 299-0530
LOUIS BERGER
(202) 331-7775 53
2'
SCALE : 1/4" = 1'-0"
0 4' 8'
BUILDING ELEVATIONS
AE202
SCALE: 1/4" = 1'-0"2 ELEVATION
SCALE: 1/4" = 1'-0"4 ELEVATION
SCALE: 1/4" = 1'-0"1 ELEVATION
SCALE: 1/4" = 1'-0"3 ELEVATION
'-0
7'-
8"
'-8
2'- 0"
'-0
5'-
0"
'-0
T.O. ROOF
COMMITTAL SHELTER
EL= 17'-8"
B.O. EAVES
COMMITTAL SHELTER
EL= 10'-0"
T.O.S.
COMMITTAL SHELTER
EL= 0'-0" (917.50' CIVIL)
T.O. ROOF
ADMIN BLDG
EL= 19'-0"
B.O. EAVES
ADMIN BLDG
EL= 14'-0"
T.O.S.
ADMIN BLDG
EL= 0'-0" (918.67' CIVIL)
T.O.S.
MAINTENANCE
EL= 2'-0"
ADMIN
MAINTENANCE
RESTROOM
COMMITTAL
SHELTER
E01
STORAGE
CLOSET
E02
9'- 0"
'-0
5'-
0"
'-0
A C D
T.O. ROOF
ADMIN BLDG
EL= 19'-0"
B.O. EAVES
ADMIN BLDG
EL= 14'-0"
T.O.S.
ADMIN BLDG
EL= 0'-0" (918.67' CIVIL)
GRADE
EL VARIES SEE CIVIL
ADMIN
W2
KEYNOTE LEGEND
KEY DESCRIPTION
1 STEEL FRAMING MEMBERS - SEE STRUCTURAL DOCUMENTS. COLOR TO MATCH P6
2 METAL SHINGLE ROOFING ASSEMBLY
3 GRADE - SEE CIVIL DOCUMENTS
4 EXTERIOR LIGHT FIXTURE - SEE RCP PLAN & ELECTRICAL DOCUMENTS
BRICK MASONRY SCREEN WALL
HOLLOW METAL DOOR
METAL GUTTER AND DOWNSPOUT
OVERHEAD COILING DOOR
DRINKING FOUNTAIN - SEE PLUMBING DOCUMENTS
10 PRE-FINISHED ALUMINUM SOFFIT PANEL
11 STEEL FRAME WINDOW
12 R-38 MINERAL WOOL INSULATION
13 METAL DECK. FINISH: EGYPTIAN WHITE
14 4" CMU WALL
2'- 0"
'-0
5'-
0"
'-0
A C D
T.O. ROOF
ADMIN BLDG
EL= 19'-0"
B.O. EAVES
ADMIN BLDG
EL= 14'-0"
T.O.S.
ADMIN BLDG
EL= 0'-0" (918.67' CIVIL)
T.O.S.
MAINTENANCE
EL= 2'-0"
MAINTENANCE
01 W2
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
KNOXVILLE, TENNESSEE
APRIL 12, 2019
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of
Office of…
This is the start of the file's text. The full file is on GovTribe.