PRODUCT DESCRIPTION
1. REQUIREMENTS: Four Utility Vehicles
Intended Use: This equipment is a very important part for the interment operations. It is used to excavate gravesites, lift and lower crypt lids, load vehicles, level uneven terrain, etc. It is also used by grounds maintenance for any renovation or special projects that may include any earth moving.
2. EXTENT OF OBLIGATION
a. Delivery requirements: [Freight of the Utility Vehicle is to be included in price]. The vendor shall deliver from Monday to Friday 0700 to 1400, to Puerto Rico National Cemetery; #50 Ave. Cementerio Nacional; Bayamón, PR 00961.
b. The vendor shall provide local warranty for parts and service
Contract Line Item
(CLIN)
Item Description
Minimum Technical Requirements Method of Evaluation
PRODUCT: Utility Vehicle
PRODUCT:
[Fill in Information]
MTR # 1 – Must provide towing Capacity of 1,587 kg
Literature Review
MTR # 2 – Must be 4wheel drive Literature Review
MTR # 3 - Must have 4wheel hydraulic disc brakes Literature Review
MTR # 4 - Must have authorized service provider near site Literature Review
MTR # 5 - Must be compatible with all TORO attachments on site i.e.
Toro Workman® 757 L Sprayer, Top dresser 1800
Literature Review
MTR # 6 - Must have a total payload capacity of 1,289 kg Literature Review
MTR # 7 - Must have at least a 2-year limited warranty Literature Review
c. Upon delivery of the utility vehicle, an authorized National Cemetery Administration (NCA) representative shall thoroughly inspect the equipment. After the inspection has been performed, NCA shall issue a written notice of acceptance or rejection. The written notice shall be issued within 15 days from the date of delivery. If a written notice is not received by the company within 15 days, NCA shall be deemed to have unconditionally accepted the supply.
3. SCHEDULE FOR DELIVERABLES
Inspection: Destination Acceptance: Destination Free on Board (FOB): N/A
Ship To and Mark For:
Puerto Rico National Cemetery (PRNC) #50 Ave. Cementerio Nacional Bayamon, PR 00961
4. POINT(S) OF CONTACT:
Davis Dumeng Voice: 787-798-8400, Ext. 224 or 241 davis.dumeng@va.gov
Or, Joel Caballero Voice: 787-798-8400, Ext. 239 joel.caballero@va.gov
Puerto Rico National Cemetery (PRNC) #50 Ave. Cementerio Nacional Bayamon, PR 00961 mailto:davis.dumeng@va.gov mailto:joel.caballero@va.gov