B.3 STATEMENT OF WORK/SPECIFICATION

1.0 Background

The Department of Veterans Affairs (VA), National Cemetery Administration (NCA) furnishes headstones, markers and niche covers for the graves of veterans worldwide. Memorial headstones, markers and niche covers are also furnished to memorialize veterans whose remains are non-recoverable.

2.0 Purpose

The purpose of this contract is to supply blank granite niche covers and memorial wall markers as noted below:

Machias National Cemetery a new cemetery in Maine requires blank granite niche covers and memorial wall markers. There is no requirement for matching existing color for either type. Delivery is to be made no later than June 3, 2019.

Indiantown Gap National Cemetery columbarium expansion project requires blank granite niche covers niche covers. These niche covers must be comparable in color and shading to the existing granite niche covers mounted at the cemetery. Sources from different states are acceptable if the MPS, Program Support Unit’s evaluation of a sample confirms that a suitable match will meet the testing standards for color, visual texture, and finish.

Reference the photos below for color and shading of stone required under this contract. For aesthetic purposes, the supplied material must match existing material having characteristics of granite listed in 6.1 from Woodbury Vermont and Elberton Georgia. Note: refer to 5.0 requesting an additional production sample be forwarded to the cemetery as well as MPS. Delivery is to be made 30 days after contract award or sooner.

3.0Material Specification
3.1Description: Niche Covers, Granite Blank for Machias NC
3.2Product Code: H1
3.3Drawing No.: A-BNC-1, Rev. date 11/11/13
3.4Quantity: 400

3.5 Color: Granite shall be a uniform shade gray color (N6.5-7.25) as judged against the Munsell Neutral Value Scale, Matte 31 – step scale.

Material Specification

3.6Description: Memorial Wall Markers, Granite Blank for Machias NC
3.7Product Code: C1
3.8Drawing No.: A-MW-1, A-MW-2, A-MW-3 Rev. date 04/14/14
3.9Quantity: 130
3.10Color: Granite shall be a uniform shade gray color (N6.5-7.25) as judged

against the Munsell Neutral Value Scale, Matte 31 – step scale.

3.11Material Specification
3.12Description: Niche Covers, Granite Blank for Indiantown Gap NC
3.13Product Code: H1
3.14Drawing No.: A-BNC-1, Rev. date 11/11/13
3.15Quantity: 7500

3.16 Color: Granite shall be a uniform shade gray color (N6.5-7.25) as judged against the Munsell Neutral Value Scale, Matte 31 – step scale.

Destination Point Deliver 400 niche covers, and 130 memorial wall markers F.O.B. Destination, within consignee’s premises to:

Machias National Cemetery 1799 U. S. Route 1 Jonesboro, ME 04648 POC.: Richard Wallace, Director Telephone#: 508-563-7113 e-mail: Richard.Wallace1@va.gov

Destination Point Deliver 7000 niche covers, F.O.B. Destination, within consignee’s premises to:

Indiantown Gap National Cemetery RR#2, Indiantown Gap Road Annville, PA 17003-9618 POC.: James R, Metcalfe, II, Director Telephone#: 717-865-5254 e-mail: James.Metcalfe@va.gov

Per prior agreement deliver 500 niche covers, F.O.B. Destination to the inscription contractor:

Veterans Monument Attn: Heather Thompson 2415 Hwy 45 North Columbus, MS 39705 Telephone# 662-328-1482

4.0 Material: Granite (Granite shall conform to the definition of granite as defined by ASTM- C119. Granite provided under this contract shall be standard grade, fine grained material as classified by the National Building Granite Quarries Association. It shall be free of cracks, seams, or starts which may impair its integrity or readability of the inscription. Niche covers containing two or more feldspar phenocrysts which exceed 6mm in any direction, shall be rejected.)

4.1 Finish: The face and sides of each niche cover shall be uniformly machine honed to a finish utilizing an 80-grit displaying a smooth satin surface, free of scratches, saw marks, rust spots and skips. The back of the niche covers must have a smooth sawn finish or better. All edges along the front, back and corners shall be uniformly rounded with a smooth 1/16 inch to 1/8 inch eased-edge aris (or chamfer). The minimum 1/16” rounding along backside edges is preferred. Four holes are to be core drilled in each cover as shown on drawing. The holes must be perpendicular to the face of the cover. The holes shall have smooth side walls, with one centerline and no visible change in the side wall from drilling the hole from opposite faces.

4.2 Scope of Work

4.3 Source of supply

All stone shall be obtained from quarries within the United States of America, having adequate capacity and facilities to meet the specified requirements. Cutting and finishing shall be done by a manufacturer equipped to process the material promptly and in strict accordance with these specifications.

4.4 Workmanship

Each niche cover shall be free from defects in workmanship. Chips, cracks, open seams, or abraded edges, will not be permitted and the repair or patching of any such defects is prohibited and will be cause for rejection. Any spalling that occurs around holes on the backside must not extend more than ¼” beyond the holes’ walls and be ≤3/32” deep. The covers shall be free of ink, oil, crayon marks, dirt, coatings, sealers and dust. Workmanship shall be in accordance with industry standards and practices.

5.0 Submittal by Potential Offerors

Due to the importance of matching coloration and graining of the granite for Indiantown Gap NC, full size niche covers as noted below will be required from all interested contractors. A 6x6 substitute will not be accepted for this contract. A single granite niche cover sample forwarded to MPS will suffice for both cemeteries noted along with a single memorial wall marker. See below for additional niche cover sample to be forwarded to Indiantown Gap NC.

Potential offerors will submit at their expense one (1) blank granite niche cover according to the specifications listed in Sections 2.0 and 3.0 above. Samples shall be representative of the stone to be used, the finish to be attained and the placement and diameter of the holes to be drilled. Testing results for the sample will be submitted per Section 6.0. The sample and testing results should be submitted by the closing date of the solicitation. The sample shall be marked clearly on the back with indelible marker, showing contractor name, solicitation number, quarry source of stone and name of stone. Any sample which arrives damaged will not be accepted.

A statement identifying the type of honing pads (or stone) used and its grit rating must be provided with the sample

This sample shall be the basis for comparison of all blank niche covers produced under this contract. The dimensions of the sample submittal shall match exactly the dimensions outlined in drawing.

Sample shall be received by Memorial Products Service (MPS) prior to closing date. If the sample is disapproved by MPS, you will receive notification by the Contracting Officer and you have until the closing date of solicitation to resubmit samples.

NO samples will be accepted after closing date.

Hand delivered samples will not be accepted.

NOTE: A full size sample granite niche cover is to be sent to Indiantown Gap NC at the addresses below:

Indiantown Gap National Cemetery RR#2, Indiantown Gap Road Annville, PA 17003-9618 POC.: James R, Metcalfe, II, Director Telephone#: 717-865-5254 e-mail: James.Metcalfe@va.gov

Once submitted, all samples become the property of the Department of Veterans Affairs and will not be returned. Submit sample and test results to the following address:

Department of Veteran Affairs

Memorial Products Service
Program Support Unit, Suite. 600
1575 Eye Street, NW
Washington, DC 20005

5.1 Full size copies of drawings are available upon request at no additional charge to potential vendors. The request should be e-mailed to the NCA Memorial Product Service (MPS) Product Support Unit at MPSProgSupport@va.gov and should include the contractor’s name, mailing address, phone number, e-mail address and the name and drawing number of the drawing(s) being requested. It is recommended that such a request be forwarded to ensure that the specifications are current and accurate. Once the request is received, the drawings will be mailed directly to the vendors via USPS, Priority Mail or e-mail.

A potential vendor should e-mail the request for drawings to MPS within a timely manner to ensure sufficient time for the drawings to be mailed. An extension to the solicitation closing date will not be granted under any circumstances.

6.0 Quality Assurance

6.1 Testing

Stone supplied under this contract shall conform to the following specifications and physical requirements. Stone shall be tested, for the tests listed below, by an approved testing laboratory and test results shall be submitted to the Memorial Products Service for approval prior to the production of the sample niche covers. Testing is required only once and should be from a representative sample of the quarry. Testing results are required for new sources of stone.

NOTE: Testing results are not required for the quarries located in the state(s) listed below:

Woodbury Vermont Elberton Georgia

6.2 Granite Testing Specifications

6.2.1 Abrasive hardness:

Granite shall have an abrasive hardness value (Ha) of not less than 10 when tested as specified in ASTM C241.

6.2.2 Absorption:

Granite shall absorb not more than 0.15 percent of moisture by weight when tested for a 48 hour period as specified in ASTM C97.

6.2.3 Compressive strength:

Granite shall have a minimum compressive strength of 7500 psi or (5.27 kg/mm2) when tested as specified in ASTM C170.

6.2.4 Modulus of rupture:

Granite shall have a minimum modulus of rupture of 1000 psi (or 0.70kg/mm2) when tested as specified in ASTM C99.

6.3Applicable Publications
6.3.1Munsell Neutral Value Scale, Matte (31 - step scale)
617 Little Britain Road, New Windsor, NY 12553 – 6148
Phone: (800) 622-2384
6.3.2ASTM, Sections C97, C99, C170, C241
American Society for Testing and Materials
Phone: (800) 622-2384
6.3.2ASTM, Sections C97, C170, C241 and C880
American Society for Testing and Materials
1220 L. Street, N.W., Suites 100-167
Washington, DC 20005
6.3.3Specifications for Architectural Granite

National Building Granite Quarries Association P.O. Box 482, Barre, VT 05641

7.0 Government Quality Assurance (QA)

7.1 Site Inspections

Quality assurance inspections of the contractor’s production processes or the contractor’s manufacturing facility may be conducted during the contract period by the designated COR’s of the Memorial Products Service (MPS) to assure contract performance and adherence. Visits to the contractor will be scheduled at a time so as to ensure inspection of the contractor’s marker production. The Government reserves the right to perform quality audit inspections without prior scheduling or notification to the contractor.

During each QA visit, a complete assessment of the contractor’s operation will be made, to include the following areas:

1. Packaging and palletizing of product to ensure compliance with all contractual requirements.

1. Contractor’s execution of quality control procedures.

1. Contractor is accurately maintaining all QA records as required, with the records indicating the quality of the markers as shipped.

1. The contractor’s handling of inventory or backlogged orders.

The contractor must assist the designated COR by providing an adequate, well lighted inspection area. Contractor personnel will provide assistance lifting, handling and moving of product.

7.2 Quality Complaints

The receipt of complaints concerning unsatisfactory quality indicating non-compliance with the contract specifications will be considered reason for an immediate visit and review of the contractor’s quality assurance program. The Government reserves the right to impose 100% Government Quality Inspections for an indefinite period due to quality problems. Indicative, but not all-inclusive, examples are:

1. Nonconforming product shipped to fill Government orders.

1. Product that passed the contractor’s inspection system and are awaiting shipment.

1. Deficiencies that adversely affect performance of the contract existing in areas such as:

2. Craftsmanship

2. Safety

2. Knowledge/training of processes and measuring tools

8.0 Packaging

8.1 Materials

All covers shall be packed in accordance with normal industry standards and commercial best practices to assure acceptance by the common carrier.

Non-metal bands shall be secured around the pallet or crating for its entire height (from top to bottom) and two additional bands shall secure the pallet or crating around the width. Banding pressure should be such that it causes no damage to the edges of the stone when packaged. Colored materials or materials capable of staining the stone (ex. uncoated cardboard, certain kinds of wood) during outdoor storage is not permitted.

The packaging and crating should protect the covers throughout the handling and storage process and during shipment and comply with the National Motor Freight Classification.

8.2 Palletizing, Markers or Covers

Each crate or pallet must not exceed 2,000 lbs.

9.0 Point of Contact at MPS

Email MPSProgSupport@va.gov of the projected delivery following the notice to proceed and of the delivery date/time following actual delivery.

MPS COR: Janis.Daley@va.gov 202-632-4826

10.0 IMPORTANT: The contractor must note on the Bills of Lading that palletized or crated monuments must be placed at the rear or side of delivery vehicles so that direct access is permitted for off-loading with a forklift.

10.1 Point of Contact for Delivery

Consignee must be contacted 24 hours prior to delivery to ensure appropriate personnel and equipment is on-site to off load product. Delivery should occur between 8:30am to 3:30pm unless other arrangements are made during the pre- notice of impending delivery.

10.2Special Site Conditions
None

END STATEMENT OF WORK

SAMPLE REVIEW - NICHE COVER (GRANITE)

Date:

Prepared by:

Contractor:

Cemetery:

Reference:

Date Received:

Quarry:

Shipping No.:

Test Results:

Criteria
Specification
Sample
Pass/Fail
Comments
Stone Coloration
N6.5-7.25
Finish (Front & Sides)
Smooth satin
Grit used
80
Pad used
Specify type used
Edges
1/8" (± 1/16") eased edge
Overall Dimensions
15-3/4" x 11-1/4" x 3/4" (± 1/16")
Deflection - Overall
≤ 1/16"
Hole Placement
1-1/4" (± 0") from horizontal and vertical edges
Hole Size
7/16" or 11mm (± 0") diameter
Spalling - Width
≤ 1/4"
Spalling - Depth
≤ 3/32"
Ref: Drawing No.:
A-BNC-1,

Rev. 04/14/14

Recommendation: (Circle one)
Approved

Disapproved

SAMPLE REVIEW - BLANK MEMORIAL WALL MARKER (GRANITE)

Date:

Prepared by:

Contractor:

Cemetery:

Reference:

Date Received:

Quarry:

Shipping No.:

Test Results:
N/A
Criteria
Specification
Sample
Accepted/Unaccepted
Comments
Stone Coloration
N6.5-7.25
Finish (Front & Sides)
Smooth satin
Grit used
80
Pad used
specify type used
Edges
1/16" -1/8" eased edge
Overall Dimensions - MWM
11-1/4" x 7-3/4" x 3/4"
Deflection
< 1/32"
Ref: Drawing No.:
A-MW-1,

Rev. 04/14/14

Recommendation:
Accepted
Rejected

Concur -

Created on 01/02/2013 Page 1 of 7 image1.png