36C78619B0018-0001001.pdf
PDF 121 KB Posted
- Attached to
- Fayetteville Burial Expansion - Proj 842CM3025
- Solicitation number
- 36C78619B0018
About this file
36C78619B0018 0001 S06 Amend-0001_Attach-1 Revision-1 Specification_32 33 00 Site Furnishings.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C78619C0130-000.docx | DOCX document | |
| 36C78619B0018-0002000.docx | DOCX document | |
| 36C78619B0018-0002000.docx | DOCX document | |
| 36C78619B0018-0001001.pdf | ||
| 36C78619B0018-0001002.pdf | ||
| 36C78619B0018-0001000.docx | DOCX document | |
| 36C78619B0018-0001002.pdf | ||
| 36C78619B0018-0001000.docx | DOCX document | |
| 36C78619B0018-005.pdf | ||
| 36C78619B0018-001.docx | DOCX document | |
| 36C78619B0018-004.pdf | ||
| 36C78619B0018-002.pdf | ||
| 36C78619B0018-006.pdf | ||
| 36C78619B0018-003.pdf | ||
| 36C78619B0018-001.docx | DOCX document | |
| 36C78619B0018-004.pdf | ||
| 36C78619B0018-006.pdf | ||
| 36C78619B0018-005.pdf | ||
| 36C78619B0018-002.pdf | ||
| 36C78619B0018-003.pdf | ||
| 36C78619B0018-000.docx | DOCX document | |
| 36C78619B0018-000.docx | DOCX document |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bid Package Submittal Project No. 842CM3025
Fayetteville National Cemetery Burial Expansion 24 May 2019
SITE FURNISHINGS
32 33 00 - 1
SECTION 32 33 00
SITE FURNISHINGS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Gravesite Layout Markers at specified locations.
2. Flower-watering stations, including trash receptacles, water spigot, and flower vase container.
1.2 RELATED REQUIREMENTS
A. Materials product data and samples: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.
B. Concrete footings: Section 03 30 53 – (Short Form) CAST-IN-PLACE
CONCRETE.
C. Cast Stone Masonry: Section 04 72 00 – CAST STONE MASONRY.
1.3 APPLICABLE PUBLICATIONS
A. Comply with references to extent specified in this section.
B. ASTM International (ASTM):
1. ASTM A53/A53M-12 - Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless.
2. B221-14 - Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes.
3. B61-15 - Steam or Valve Bronze Castings.
4. B62-15 - Composition Bronze or Ounce Metal Castings.
C. National Association of Architectural Metal Manufacturers (NAAMM):
1. AMP 500-06 Metal Finishes Manual.
1.4 SUBMITTALS
A. Submittals Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES:
B. Submittal Drawings:
1. Show size, configuration, and fabrication and installation details.
2. Show floral regulations decal content, lettering color and background color.
C. Manufacturer's Literature and Data:
1. Description of each product.
2. Installation instructions.
3. Warranty.
D. Samples:
32 33 00 - 2
1. Each Product: each type and color.
a. Submit quantity required to show full color and texture range.
2. Trash Receptacle, Markers Flower Vase Receptacle: Full sized, complete assembly.
3. Approved samples may be incorporated into work.
E. Qualifications: Substantiate qualifications comply with specifications.
1. Manufacturer with project experience list.
2. Fabricator with project experience list.
3. Installer with project experience list.
1.5 QUALITY ASSURANCE
A. Manufacturer, Fabricator, Installer Qualifications:
1. Regularly manufactures, fabricates, and installs specified products.
2. Manufactured, Fabricated, Installed, specified products with satisfactory service on five similar installations for minimum five years.
a. Project Experience List: Provide contact names and addresses for completed projects.
1) Photographs, drawings and other documents showing character and quality of final installation.
B. Installer Qualifications: Product manufacturer.
1. Regularly installs specified products.
2. Installed specified products with satisfactory service on five similar installations for minimum five years.
a. Project Experience List: Provide contact names and addresses for completed projects.
1) Photographs, drawings and other documents showing character and quality of final installation.
1.6 DELIVERY
A. Deliver products in manufacturer's original sealed packaging.
B. Mark packaging, legibly. Indicate manufacturer's name or brand, type, color, production run number, and manufacture date.
C. Before installation, return or dispose of products within distorted, damaged, or opened packaging.
1.7 STORAGE AND HANDLING
A. Store products indoors in dry, weathertight conditioned facility.
B. Protect products from damage during handling and construction operations.
32 33 00 - 3
1.8 WARRANTY
A. Construction Warranty: FAR clause 52.246-21, "Warranty of
Construction."
B. Manufacturer's Warranty: Warrant hydrant post, trash and vase receptacles against material and manufacturing defects.
1. Warranty Period: Refer to manufacturer.
PART 2 - PRODUCTS - GENERAL
2.1 PRODUCTS - GENERAL
A. Provide each product from one manufacturer and from one production run
2.2 FLOWER WATERING STATIONS
A. General: Materials, finishes and colors as indicated on Drawings.
2.3 GRAVESITE LAYOUT MARKERS
A. General: Provide both Gravesite Grid Monuments and Gravesite Grid
Markers.
1. Gravesite Grid Monuments: Bronze survey marker (monument marker) set into cast-in-place concrete base
a. Materials:
1) Monument Base: Precast concrete monument base, minimum of
24.1 MPa (3,500 psi) @ 28 days, reinforcement and dimensions
as indicated on Drawings.
2) Monument Marker: Domed-top, 89 mm (3 1/2") diameter, bronze concrete survey marker with integral locator magnet, and flared anchor post for concrete installation.
2. Gravesite Grid Markers: Bronze survey marker (Grid Marker) with insulator set on No. 10 soft metric (No. 6) rebar.
a. Materials:
1) Grid Marker: Domed-top, 81 mm (3 1/4 inches) diameter, bronze concrete marker.
2) Rebar: Manufacturer's standard rebar, No. 10 soft metric (No.
6); dimension as indicated on Drawings.
3) Insulator: Manufacturer's standard plastic insulator.
B. Text and Cross-hairs: Top text as indicated on Drawings.
1. Text: All caps, 4.75 mm (3/16 inches) high.
2. Cross hairs: Field engrave as indicated on Drawings. Align gravesite grid and engrave based on surveyed location data.
32 33 00 - 4
2.4 TRASH RECEPTACLE
A. Trash Receptacles: Victor Stanley RB36 as indicated on Drawings or approved equal
1. Steel Body Construction:
a. Vertical Bar: Solid steel, 9.53 mm x 25.4 mm (3/8 x 1 inch).
b. Horizontal Bands: Solid steel, 6.35 mm x 63.5 mm (1/4 x
2-1/2 inches).
c. Support Bars: Steel, 9.53 mm x 76.2 mm (3/8 x 3 inches).
d. Top Ring: Solid steel, 15.88 mm (5/8 inch).
e. Leveling Feet: 9.53 mm (3/8 inch) diameter threaded steel shaft.
f. Joints: Fully welded, grind smooth.
2. Capacity: 136 liters (36-gallon).
3. Inner Liner: High-density plastic inner liner, 2.72 kg (6 lbs.)
maximum weight.
4. Lids: Manufacturer’s standard steel tapered formed lid, secured with stainless steel aircraft cable and attachments, with self-closing door.
5. Mounting Plate: Standard (1) anchor bolt hole.
6. Identification: Identify trash receptacle with the word “TRASH”, material, finish, color, letter style and size as indicated on
Drawings.
7. Steel Powder Coat Finish: Manufacturer's standard shot blasted, etched, phosphatized, preheated, and electrostatically polyester, powder coatings, 8-10 mils (200-250 microns) dry film thickness.
a. Standard Colors: Victor Stanley Standard Bronze.
b.
2.5 FLOWER VASE RECEPTACLE
A. Materials: Regularly manufactured for VA Cemeteries use, with special lightweight hinged lid.
1. Size: As indicated on Drawings.
2. Finish and Color: Same as trash receptacle, except as follows:
a. Identification: Identify flower vase receptacles with the word
“FLOWER VASES” as indicated on Drawings.
b. Decal: “Floral Regulations” decal, factory applied pressure sensitive vinyl on top of receptacle lid as indicated on
Drawings. Contents and color approved by Contracting Officer's
Representative (COR).
32 33 00 - 5
2.6 WATER SPIGOT ASSEMBLIES
A. Faucet Post.
1. Housing: Concrete Faucet Posts shall be manufactured in accordance with Section 04 72 00 Cast Stone Masonry using reinforced wet cast concrete with finish made to emulate stone by the use of acid etching process following casting. Finish, color and texture, as well as dimensional conformance shall be demonstrated by submitting samples of the marker, minimum of 300mm (12") in length, during the submittal process. Submit shop drawings indicating all dimensions and tolerances, as well as reinforcing. The shop drawings and sample shall include the details space for the pipes, appurtenances, and spigot as well as room for assembly and attachment to produce the fully functional FWS spigot assembly as specified. An acceptable sample must be obtained prior to manufacturing the units.
a. Color: ‘Pewter’ by Davis Color or approved equal.
2. Inner Supply: 3/4” threaded brass nipple.
3. Nozzle: Solid brass casting.
4. Outlet: 1/2” threaded brass nipple.
B. Water spigots as indicated on Drawings, ADA compliant, spigot paddle operated, maximum 2 kg (5 lbs.) force water flow, connected to irrigation main line.
1. Self-closing valve shall be Haws model # 6252 EHLF with brass finish or approved equal.
2.7 FINISHES
A. Steel Finish:
1. Powder-Coat Finish: Manufacturer's standard two-coat finish system consisting of the following:
a. One coat primer.
b. One coat thermosetting topcoat.
c. Dry-film Thickness: 0.05 mm (2 mils) minimum.
d. Color: Refer to Section 09 06 00, SCHEDULE FOR FINISHES.
B. Aluminum Anodized Finish: NAAMM AMP 500.
1. Clear Anodized Finish: AA-C22A41; Class I Architectural, 0.018 mm
(0.7 mil) thick.
2. Color Anodized Finish: AA-C22A42 or AA-C22A44; Class I
Architectural, 0.018 mm (0.7 mil) thick.
3. Clear Anodized Finish: AA-C22A31; Class II Architectural, 0.01 mm
(0.4 mil) thick.
32 33 00 - 6
4. Color Anodized Finish: AA-C22A32 or AA-C22A34; Class II
Architectural, 0.01 mm (0.4 mil) thick.
C. Aluminum Paint finish:
1. Baked-Enamel or Powder-Coat Finish: Polyester powder coating. Comply with manufacturer's coating process.
2. Fluorocarbon Finish: AAMA 2605; 70 percent fluoropolymer resin, 2-coat system.
2.8 ACCESSORIES
A. Primers:
B. Welding Materials: AWS D1.1/D1.1M, type to suit application.
C. Fasteners: Tamper resistant Stainless steel, acorn nut.
D. Anchors:
E. Galvanizing Repair Paint: MPI No. 18.
F. Touch-Up Paint: Match shop finish.
G. Concrete Footing: Comply with SECTION 033000 - CAST-IN-PLACE CONCRETE.
PART 3 - EXECUTION
3.1 INSPECTION
A. Inspect planned installation materials and locations. Notify COR of any discrepancies in conditions.
1. Verify materials are damage free and compliant with Drawings. Report non-compliance to COR.
3.2 PREPARATION
A. Examine and verify substrate suitability for product installation.
B. Protect existing construction and completed work from damage.
3.3 INSTALLATION - GENERAL
A. Install products according to manufacturer's instructions and approved submittal drawings.
1. When manufacturer's instructions deviate from specifications, submit proposed resolution for COR consideration.
2. Install items rigid and plumb as indicated on Drawings.
B. Gravesite Grid Monuments and Markers:
1. Install at locations indicated on Drawings.
C. Flower Watering Stations:
1. Stake flower watering station location. Obtain COR approval before forming concrete pad. Install concrete pad according to SECTION
033000 - CAST-IN-PLACE CONCRETE.
32 33 00 - 7
2. Anchor flower vase container as indicated on Drawings and manufacturer's instructions.
D. Trash Receptacle:
1. Anchor receptacle as indicated on Drawings and manufacturer’s instructions.
E. Water Spigot:
1. Install water spigot assemblies according to manufacturer’s instructions, including pipe, isolation valve, fittings, pressure reducing valve and valve boxes. Install washed stone for splash area.
3.4 CLEANING
A. Clean exposed surfaces. Remove contaminants and stains.
B. Polish exposed surfaces gloss.
C. Remove excess material and debris. Clean above ground portions of receptacles and other site improvements.