Attachment 4 - Drawings - PACT B4 - Part 2.pdf
PDF 18 MB Posted
- Attached to
- Y1DA--656-400 Construct PACT B4 Minor Construction - St. Cloud, MN Federal contract opportunity
- Solicitation number
- 36C77624B0021
About this file
This document appears to be Attachment 4 - Drawings - PACT B4 - Part 2.pdf, which is related to the federal contract opportunity for Solicitation Number 36C77624B0021, "Y1DA--656-400 Construct PACT B4 Minor Construction - St. Cloud, MN" issued by the Department of Veterans Affairs Technology Acquisition Center Austin.
The document contains detailed construction drawings and specifications for the PACT B4 Minor Construction project in St. Cloud, MN. The drawings cover various elements of the construction project such as floor plans, elevations, mechanical, electrical, and plumbing systems. This appears to be a set of technical design documents intended to provide contractors with the necessary details to submit proposals for the construction work.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C77624B0021 0002.pdf | ||
| Technical Questions - PACT B4.pdf | ||
| 36C77624B0021 0001.docx | DOCX document | |
| S06-Site Visit Sign-in PACT B4 - 0001.pdf | ||
| Attachment 12 - Site Visit Map.pdf | ||
| Attachment 9 - Brand Name JandA - St Cloud.pdf | ||
| Attachment 3 - Drawings - PACT B4 - Part 1.pdf | ||
| Attachment 2 - Specifications - PACT B4 - Vol 02.pdf | ||
| Attachment 11 - Division Cost Breakdown.xlsx | XLSX spreadsheet | |
| Attachment 10 - Wage Rates - Stearns County 7.9.pdf | ||
| Attachment 7 - Asbestos and Lead Report.pdf | ||
| Attachment 6 - Drawings - PACT B4 - Part 4.pdf | ||
| Attachment 1 - Specifications - PACT B4 - Vol 01.pdf | ||
| Attachment 8 - Limitations on Subcontracting - Construction.docx | DOCX document | |
| Attachment 5 - Drawings - PACT B4 - Part 3.pdf | ||
| 36C77624B0021_1.docx | DOCX document |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T/ FIRST FLOOR
EL. 100'-0" (V.I.F.)
T/ BASEMENT FLOOR
EL. 89'-6" (V.I.F.)
T/ 2ND LEVEL
EL. 111'-6" (V.I.F.)
6 6
T/ ROOF LEVEL
EL. 122'-0" (V.I.F.)
1'- 6"
1'- 4"
15'-4"
J.4
LINTEL
3 TYP
T/ FIRST FLOOR
EL. 100'-0" (V.I.F.)
T/ 2ND LEVEL
EL. 111'-6" (V.I.F.)
1'-0" 1'-0"5 5
4 1 /2"
EXIST. FLOOR SLAB (V.I.F.)
EXIST. CONC. BEAM (V.I.F.)
NEW CONC. SLAB
LINTEL, SEE PLAN & SCHED.
EXIST. FLOOR SLAB (V.I.F.)
EXIST. CONC. BEAM (V.I.F.)
NEW CONC. SLAB
SHIM TIGHT & GROUT W/ NON-SHRINK
LINTEL, SEE PLAN & SCHED.
4 1 /2"
CONT. L5x3 1/2 (LLV), SEE ELEVATION
SEE 4/S203 FOR CONCEPTUAL SHORING
SEE 4/S203 FOR CONCEPTUAL SHORING
2ND FLOOR
2ND FLOOR
EXISTING FLOOR SLAB (V.I.F.)
EXIST. CONC. BEAM (V.I.F.)
NEW CONC. SLAB
LINTEL, SEE PLAN & SCHED.
2ND FLOOR
SEE KEYNOTE 12/S200
GROUT
SHIM TIGHT & GROUT W/ NON-SHRINK
CONT. L5x3 1/2 (LLV), SEE ELEVATION
SEE KEYNOTE 12/S200
GROUT
2" CLR.
2" CLR.
NOTE:
X-RAY BEAM TO LOCATE
REBAR. RELOCATE
ANCHORS AS REQ'D TO
MISS REBAR
NOTE:
X-RAY BEAM TO LOCATE
REBAR. RELOCATE
ANCHORS AS REQ'D TO
MISS REBAR
NOTE:
X-RAY BEAM TO LOCATE
REBAR. RELOCATE
ANCHORS AS REQ'D TO
MISS REBAR
SHIM TIGHT & GROUT W/ NON-SHRINK
GROUT
4 1 /2"
CONT. L5x3 1/2 (LLV), SEE ELEVATION
SEE KEYNOTE 12/S200
CONT. 2x2 KEYWAY CENTERED
IN SLAB
CONSTRUCTION JOINT (CJ)
STOP WWF AT JOINT
VAPRO BARRIER (VB)
COMPACTED GRANULAR FILL (CGF)
SAWCUT JOINT (SJ) OR
TOOLED JOINT (TJ)
SEE PLAN FOR JOINT TYPES & LOCATIONS
400 SQ. FT. SLAB AREA WITHIN JOINTS MAX., U.N.
T 1/4
T
JOINT ALL AROUND
COLUMN, SEE PLAN
JOINT ALL AROUND
32"Ø
2'-8 ", T
YP.
JOINT FILLER
JOINT FILLER
FIBERBOARD
FIBERBOARD
656-400
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DRAWINGS
10/28/22ISSUE FOR 100% CONSTRUCTION DRAWINGS
JOHNSONWILBUR ADAMS, INC.
Wheaton, Illinois 60187 330 S. Naperville Road Suite 300
STRUCTURAL ENGINEERING
CONTRACTOR NOTE:
CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO BID TO ENSURE ALL CONFLICTS FOR INSTALLATION OF NEW WORK HAS BEEN IDENTIFIED AND ANY WORK REQUIRED TO MODIFY EXISTING IS INCLUDED IN BID
PRICE.
S203
STRUCTURAL -
SECTIONS AND DETAILS
MEANS AND METHOD OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE
GENERAL CONTRACTOR. THE FOLLOWING IS A CONCEPTUAL SHORING
PROCEDURE THAT IS TO BE CONFIRMED BY THE GENERAL CONTRACTOR.
1. VERIFY HELICAL PIER SHORING OF FOUNDATION INSTALLED.
2. INSTALL LOAD DISTRIBUTION MC18 ON FOUNDATION WALL BELOW THE NEW
OPENING.
3. REMOVE 3' SECTIONS OF BRICK VENEER JUST BELOW THE 2ND FLOOR FOR
PLACEMENT OF BRICK VENEER SHELF ANGLE. INSTALL SHELF ANGLE.
REMOVE BRICK VENEER FROM BOTTOM OF SHELF ANGLE TO 1ST FLOOR
(TOP OF CONCRETE FOUNDATION) WITHIN NEW OPENING AREA.
4. INSTALL A MINIMUM OF TWO SHORING POSTS WITHIN THE NEW OPENINGS.
THE SHORING POSTS TO BE LOCATED IN THE PLANE OF THE BRICK VENEER
THAT WAS REMOVED. ADD SEAT ANGLE EXTENSION TO FOUNDATION IF
REQUIRED TO SUPPORT THE SHORING POSTS.
5. CAREFULLY SAWCUT 1' WIDE OPENINGS AT THE NEW C1 COLUMN/MASORNY
PIER LOCATIONS. THE OPEING TO EXTEND FROM THE BOTTOM OF THE 2ND
FLOOR CONCRETE BEAM TO THE 1ST FLOOR TOP OF FOUNDATON WALL.
6. INSTALL NEW C1 COLUMNS/MASONRY PIERS.
7. REMOVE EXISTING CMU WITHIN OPENING.
8. REMOVE TEMPORARY GYP CORRIDOR WALL ON INSIDE OF BUILDING.
9. SLIDE NEW LINTEL BETWEEN SHORING POSTS INTO CORRIDOR.
10. ROTATE LINTEL INTO PLACE AND COMPLETE CONNECTIONS TO C1 COLUMNS
OR PLACE ON MASONRY PIER.
11. SHIM TIGHT BETWEEN STEEL LINTEL AND BOTTOM OF EXISTING CONCRETE
BEAM.
12. REMOVE SHORING POSTS.
13. PATCH GYP BOARD WALL AS REQUIRED.
NTS
CONCEPTUAL SHORING SOUTH WALL
S203
0 2'1'1/2' 3'3/4"=1'-0"
SECTION
S203
0 2'1'1/2' 3'3/4"=1'-0"
SECTION
S203
0 2'1'1/2' 3'3/4"=1'-0"
SECTION
S203
NTS
TYPICAL SLAB JOINTS
S203
NTS
TYPICAL ISOLATION JOINTS
S203
10/28/2022
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
ISSUE FOR 100% CONSTRUCTION DOCUMENTS
H O
O
KS
SH
EL
F
PA
PE
R T
O W
EL
D
IS
PE
N
SE
R O
R M
U
LT
I-
PU
R
PO
SE
U
N
IT
M O
P
ST
R
IP
SH
EL
F
M
IR
R O
R
O R
M
IR
R O
R
SH
EL
F
PU
SH
B U
TT
O
N
SW
IT
C H
O R
W
AL
L O
U
TL
ET
AB
O
VE
C O
U N
TE
R
H O
O
KS
IN
TE
R
IO
R W
AL
L
M
TD
R O
O M
SI
G
N
AG
E
HALL
LANTERN
SP
EA
KE
R
O R
F
IR
E
AL
AR
M
D
EV
IC
E
C
LO
C K
O U
TL
ET
W
AL
L
AN
D A
LL
EM
ER
G
EN
C
Y
PH
O N
ES
EL
EC
TR
IC
, O U
TL
ET
TE
LE
PH
O
N E
O R
C
AB
LE
J
AC
K
FI
R
E
AL
AR
M
PU
LL
S
TA
TI
O
N
G R
AB
B
AR
ST
D
W
AT
ER
C
LO
SE
T
FL
O O
R M
TD
FL
O
O R
M
TD
W
AT
ER
C
LO
SE
T
G R
AB
B
AR
EL
EV
AT
O R
EN
TR
AN
C
E
SA
N
IT
AR
Y N
AP
KI
N D
IS
PO
SA
L
TI
LT
M
IR
R O
R
TO
IL
ET
PA
PE
R
H O
LD
ER
M O
TO
R
S
TA
R
TE
R S
SA
FE
TY
S
W
IT
C H
TH
ER
M O
ST
AT
H
VA
C C
O N
TR
O
LS
" 48
MOUNTING DIMENSIONS (NOTE: THIS IS A "UNIVERSAL SHEET", ITEMS SHOWN MAY NOT ALL BE APPLICABLE TO THIS PROJECT)
NOTES:
1. MOUNTING DIMENSIONS SHOW ACCESSIBLE AND NON-ACCESSIBLE CONDITIONS. WHEN ONLY ONE OPTION IS SHOWN - ALL ITEMS IN PROJECT SHALL BE ACCESSIBLE. WHEN ITEMS CAN
BE ACCESSIBLE OR NON ACCESSIBLE DRAWINGS SHALL INDICATE LOCATION OF ACCESSIBLE ITEMS BY THIS SYMBOL:
2. COORDINATE ITEMS SHOWN ON THIS DRAWING WITH PLANS AND SPECIFICATIONS FOR ACTUAL ITEMS USED ON THIS PROJECT.
EVERY ITEM SHOWN ON THIS DRAWING MAY NOT BE USED ON THIS PROJECT.
IS
O
LA
TE
D G
R O
U N
D
PA
N
EL
S
H
AN
D R
AI
L
8"
6' -8
" T O
B / O
F D
EV
IC
E
PE
R N
FP
A
6' -8
" T O
B
O F
C
LO
C K
4' -0
ROBE HOOK,
CENTER ON
DOOR
4"
18"
MIN.
M
FG
S
TA
N D
6" 12"
18"
7"-9"
4"
" M
AX
20"
M
IN
42" 12" 39"-41"
FRONT
OF W.C.
" M
IN
FLOOR
DESIGNATION
(BOTH JAMBS)
CALL
BUTTONS
8"
COUNTER
FI
R
E H
O
SE
EX
TI
N
G U
IS
H
ER
O
R C
O M
BI
N
AT
IO
N C
AB
IN
ET
EL
EC
TR
IC
PA
N
EL
O
R C
AB
IN
ET
FI
R
E H
O
SE
R
AC
K O
R V
AL
VE
FI
R
E
EX
TI
N
G U
IS
H
ER
PO
W
ER
PA
N
EL
VA
LV
E C
AB
IN
ET
EL
EC
TR
IC
PA
N
EL
O
R C
AB
IN
ET
" M
IN
" M
AX
TO
P O
F C
AB
8" C
R
AS
H R
AI
L
TO
C
H
AN
D
LEL
TO
C
H
AN
D
LEL
6' -0
FU
LL
H
EI
G H
T M
IR
R
O R
3' -0
TO
U
C H
LE
SS
AU
TO
M
AT
IC
D
O O
R O
PE
R
AT
O
R
4' -0
C
AR
D
R
EA
D
ER
KE
YP
AD
S
EQ. EQ.
SE
AT
C O
VE
R
D
IS
PE
N
SE
R
M
IR
R O
R
O R
M
IR
R O
R
SH
EL
F O
R M
ED
IC
IN
E
C
AB
IN
ET
ED
G
E O
F O
U
TL
ET
O
R W
AL
L
W / O
U
TL
ET
& TYPE A
" 72
" M
IN
M
AX
24" MAX - 15" MIN
LA
V 29
M
IN 34
M
AX
" T
O
18" MIN
8" MIN
INSULATE PIPES
24"
656-400
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
DEMOLITION, ARCHITECTURAL
AND ELEVATION KEYNOTE
REVISION CLOUD
AND NUMBER
DETAIL BUBBLE
DETAIL NUMBER
DRAWING NUMBER
ROOM TAG
ROOM NAME
ROOM NUMBER
WALL SECTION
DETAIL NUMBER
DRAWING NUMBER
INTERIOR ELEVATION
(MULTIPLE)
INTERIOR ELEVATION
(SINGLE)
NORTH ARROW
WINDOW TAG
DOOR NUMBER
PARTITION TAG
ELEVATION TAG
EARTH
CONCRETE
ELEVATION/SECTION STEEL
BRICK CMU GROUT
GRAVEL FILL LIMESTONE CONCRETE PLAN
POINT OF CONNECTION
ACM ASBESTOS CONTAINING MATERIAL
ACT ACOUSTICAL CEILING TILE
ADJ ADJACENT
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
AMT AMOUNT
APPROX APPROXIMATE
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVG AVERAGE
BAT BATTEN
BD BOARD
BLDG BUILDING
BLK BLOCKING
BM BEAM
BO BY OWNER
BOD BASIS OF DESIGN
CEM CEMENT
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
CO CONTRACTING OFFICER
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CORR CORRIDOR
CT CERAMIC TILE
CTR CENTER
CTRL CONTROL
DAT DATUM
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA DIAMETER
DIFF DIFFUSER
DIM DIMENSION
DN DOWN
DR DOOR
DTL DETAIL
DWG DRAWING
E EAST
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC
ELEV ELEVATOR
ENCL ENCLOSURE
EQ EQUAL
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
FA FIRE ALARM
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF&E FURNITURE, FIXTURE, AND
EQUIPMENT
FHC FIRE HOSE CABINET
FIG FIGURE
FIN FINISH
FIXT FIXTURE
FL FLOOR
FO FACE OF
FP FIRE PROTECTION OR FIREPROOF
FRT FIRE-RESISTANT TREATED
FT FOOT
FTG FOOTING
GC GENERAL CONTRACTOR
GL GLASS
GYP BD GYPSUM BOARD
HAZ MAT HAZARDOUS MATERIALS
HDW HARDWARE
HM HOLLOW METAL
HT HEIGHT
INCL INCLUDED
INSUL INSULATION
INT INTERIOR
JAN JANITOR
JST JOIST
JT JOINT
J-BOX JUNCTION BOX
LAM LAMINATE
LAV LAVATORY
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LL LEAD LINED
LT LIGHT
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MLWK MILLWORK
MO MASONRY OPENING
MR MOISTURE RESISTANT
MTD MOUNTED
MTG MOUNTING
MTL METAL
N NORTH
N/A NOT APPLICABLE
NAT NATURAL
NIC NOT IN CONTRACT
NO NUMBER
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OCC OCCUPANT(S), OCCUPANCY
OH OPPOSITE HAND
OPNG OPENING
OPT OPTIONAL
PAT PATTERN
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER OR PLASTIC
PR PAIR
PRE PREFINISHED
PREP PREPARATION
PROVIDE FURNISH AND INSTALL
PT PAINT
PTME PAINT TO MATCH EXISTING
PTN PARTITION
PWR POWER
QT QUARRY TILE
QTR QUARTER
QTY QUANTITY
R RADIUS
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
REC RECESSED
RECPT RECEPTACLE
REINF REINFORCED
REQD REQUIRED
RM ROOM
RO ROUGH OPENING
S SOUTH
SAN SANITARY
SCHED SCHEDULE
SF SQUARE FOOT (FEET)
SHT SHEET
SIM SIMILAR
SOW SCOPE OF WORK
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STOR STORAGE
SUSP SUSPEND
SV SHEET VINYL
T&G TONGUE AND GROOVE
T TEMPERED
TEMP TEMPERED
TERR TERRAZZO
THK THICK
TO TOP OF
TSTAT THERMOSTAT
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VAR VARIES
VCT VINYL COMPOSITION TILE
VENT VENTILATION
VIF VERIFY IN FIELD
VOL VOLUME
VWC VINYL WALL COVERING
W WEST
W/ WITH
W/O WITHOUT
WC WALL COVERING
WD WOOD
WDW WINDOW
WWF WELDED WIRE FABRIC
FIRE EXTINGUISHER
CABINET
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
Dennis Mika
656-400
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
KEY PLAN
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE/SMOKE BARRIER
2-HOUR FIRE/SMOKE BARRIER
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(EXISTING)
1-HOUR FIRE/SMOKE BARRIER (EXISTING)
2-HOUR FIRE/SMOKE BARRIER (EXISTING)
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
KEY PLAN
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE/SMOKE BARRIER
2-HOUR FIRE/SMOKE BARRIER
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(EXISTING)
1-HOUR FIRE/SMOKE BARRIER (EXISTING)
2-HOUR FIRE/SMOKE BARRIER (EXISTING)
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
UCF
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
KEY PLAN
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE/SMOKE BARRIER
2-HOUR FIRE/SMOKE BARRIER
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(EXISTING)
1-HOUR FIRE/SMOKE BARRIER (EXISTING)
2-HOUR FIRE/SMOKE BARRIER (EXISTING)
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
KEY PLAN
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE/SMOKE BARRIER
2-HOUR FIRE/SMOKE BARRIER
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(EXISTING)
1-HOUR FIRE/SMOKE BARRIER (EXISTING)
2-HOUR FIRE/SMOKE BARRIER (EXISTING)
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
KEY PLAN
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
AREA NOT INCLUDED IN CONTRACT
NEW PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE/SMOKE BARRIER
2-HOUR FIRE/SMOKE BARRIER
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(EXISTING)
1-HOUR FIRE/SMOKE BARRIER (EXISTING)
2-HOUR FIRE/SMOKE BARRIER (EXISTING)
LCDA
X
JMcAllister Snapshot
UCFUCFUCF
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
KEY PLAN
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
ZONE 1
ZONE 2
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
AREA NOT INCLUDED IN CONTRACT
NEW PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE/SMOKE BARRIER
2-HOUR FIRE/SMOKE BARRIER
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(EXISTING)
1-HOUR FIRE/SMOKE BARRIER (EXISTING)
2-HOUR FIRE/SMOKE BARRIER (EXISTING)
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
RD
OD
RD
OD
RAMP UP
STAIR
TO B1-2
656-400
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
KEY PLAN
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
X
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE/SMOKE BARRIER
2-HOUR FIRE/SMOKE BARRIER
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(EXISTING)
1-HOUR FIRE/SMOKE BARRIER (EXISTING)
2-HOUR FIRE/SMOKE BARRIER (EXISTING)
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
KEY PLAN
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
ZONE 1
ZONE 2
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE/SMOKE BARRIER
2-HOUR FIRE/SMOKE BARRIER
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(EXISTING)
1-HOUR FIRE/SMOKE BARRIER (EXISTING)
2-HOUR FIRE/SMOKE BARRIER (EXISTING)
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
KEY PLAN
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
X
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE/SMOKE BARRIER
2-HOUR FIRE/SMOKE BARRIER
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(EXISTING)
1-HOUR FIRE/SMOKE BARRIER (EXISTING)
2-HOUR FIRE/SMOKE BARRIER (EXISTING)
YHDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
X
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
KEY PLAN
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
ZONE 1
ZONE 2
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE/SMOKE BARRIER
2-HOUR FIRE/SMOKE BARRIER
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(EXISTING)
1-HOUR FIRE/SMOKE BARRIER (EXISTING)
2-HOUR FIRE/SMOKE BARRIER (EXISTING)
YHDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
KEY PLAN
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
ZONE 1
ZONE 2
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
X
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE/SMOKE BARRIER
2-HOUR FIRE/SMOKE BARRIER
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(EXISTING)
1-HOUR FIRE/SMOKE BARRIER (EXISTING)
2-HOUR FIRE/SMOKE BARRIER (EXISTING)
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
KEY PLAN
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
ZONE 1
ZONE 2
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
X
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE/SMOKE BARRIER
2-HOUR FIRE/SMOKE BARRIER
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(EXISTING)
1-HOUR FIRE/SMOKE BARRIER (EXISTING)
2-HOUR FIRE/SMOKE BARRIER (EXISTING)
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
KEY PLAN
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
ZONE 1
ZONE 2
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
X
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1-HOUR FIRE/SMOKE BARRIER
2-HOUR FIRE/SMOKE BARRIER
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(EXISTING)
1-HOUR FIRE/SMOKE BARRIER (EXISTING)
2-HOUR FIRE/SMOKE BARRIER (EXISTING)
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
'-6
'-6
'-6
'-6
'-6
656-400
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
X
AREA NOT INCLUDED IN CONTRACT
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
LCDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
X
LRDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
LRDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
LRDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
10/28/22CONSTRUCT PACT CLINIC
BUILDING 4 FIRST FLOOR
www. bancroft-ae.com
BAE PROJECT NO. 18-116
700 Nicholas Blvd. Suite 300 Elk Grove Village, IL 60007
T: 847.952.9362
ARCHITECT/ENGINEER OF RECORD
ST. CLOUD VAHCS
ST. CLOUD, MN 56303
10/28/2022 - ISSUE FOR 100 % CONSTRUCTION DOCUMENTS
10/28/22ISSUE FOR 100% CONSTRUCTION DOCUMENTS
LRDA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the state of Minnesota.
Signature:
Typed or Printed Name:
Date: License Number:
| 04_20221027 - VA BLDG 04 PACT - ARCH.pdf (p.27-79) |
| A001 ARCHITECTURAL - ABBREVIATIONS & SYMBOLS |
| AD100 ARCHITECTURAL - DEMO COOR AND KEY NOTES |
| AD101 ARCHITECTURAL - DEMO PLAN - BASEMENT |
| AD102 ARCHITECTURAL - DEMO PLAN - BASEMENT CEILING |
| AD103 ARCHITECTURAL - DEMO PLAN - FIRST FLOOR |
| AD104 ARCHITECTURAL - DEMO PLAN - FIRST FLOOR CEILING |
| A010 ARCHITECTURAL - COMPOSITE PLAN - BASEMENT |
| A011 ARCHITECTURAL - COMPOSITE PLAN - FIRST FLOOR |
| A012 ARCHITECTURAL - COMP PLAN - SECOND FLOOR - LOWER ROOF |
| A013 ARCHITECTURAL - COMPOSITE CEILING PLAN - FIRST FLOOR |
| A100 ARCHITECTURAL - PLAN - BASEMENT |
| A101.1 ARCHITECTURAL - PLAN - FIRST FLOOR - ZONE 1 |
| A101.2 ARCHITECTURAL - PLAN - FIRST FLOOR - ZONE 2 |
| A131.1 ARCHITECTURAL CEILING PLAN - FIRST FLR - ZONE 1 |
| A131.2 ARCHITECTURAL CEILING PLAN - FIRST FLR - ZONE 2 |
| A301 ARCHITECTURAL - BUILDING SECTIONS |
| A310 ARCHITECTURAL - WALL SECTIONS |
| A311 ARCHITECTURAL - WALL SECTIONS |
| A312 ARCHITECTURAL - WALL SECTIONS |
| A313 ARCHITECTURAL - WALL SECTIONS |
| A401 ARCHITECTURAL - ROOM ELEVATIONS |
| A402 ARCHITECTURAL - ROOM ELEVATIONS |
| A403 ARCHITECTURAL - ROOM ELEVATIONS |
| A404 ARCHITECTURAL - ROOM ELEVATIONS |
File details come from the government source that posted it. Updated .