This file attachment relates to a federal contract solicitation for construction services. The Department of Veterans Affairs Technology Acquisition Center Austin is seeking bids for Project 202-318-REHAB Building Construction at the TOGUS-ME location under Solicitation Number 36C77624B0006. Drawings for the project are provided in the 17MB PDF file. Construction services required include rehabilitation of an existing building. The bid response deadline is not specified in the attachment but the solicitation is for firm-fixed-price bids. No other details on offer terms, pricing, schedules, or incumbent are included in this file attachment.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
4 4
A
A
B
B
C
C
D
D E
E 0.50.5
A.5
A.5
STAIR 2
S2-1
124 SF
STAFF BREAK
A-109
190 SF
STAFF TLT
A-110
64 SF
OFFICE 3
A-111
81 SF
OFFICE 1
A-112
83 SF
OFFICE 2
A-113
104 SF
MULTIPURPOSE
A-108
210 SF
MULTIPURPOSE
A-107
212 SF
EXAM RM
A-106
117 SF UDS TLT
A-105
72 SF
REC ROOM & KITCHEN
A-103
857 SF
PUBLIC TLT
A-104
65 SF
ELEVATOR
A-001
89 SF
CORRIDOR
A-131
416 SF
SHARED LAUNDRY
A-114
185 SF
MEN'S LOUNGE
A-115
331 SF
WOMEN'S LOUNGE
A-116
224 SF
FAMILY VISITATION
A-117
236 SF
TELECOM ROOM
A-119
93 SF
HAC
A-118
70 SF
FIRE RISER ROOM
A-120
74 SF
VESTIBULE
A-100
148 SF
WAITING
A-101
663 SF
RECEPTION
A-102
103 SF
STAIR 1
S1-1
187 SF
CLOSET
A-101A
31 SF
CORRIDOR
A-132
114 SF
CORRIDOR
A-130
180 SF
CORRIDOR
A-133
502 SF
CORRIDOR
A-134
76 SF
DEDUCT ALT 1: ELIMINATE CONNECTING CORRIDOR.
EXTERIOR PATHWAY ONLY.
REMOVE FIRE SPRINKLERS FROM THIS AREA IF THIS
DEDUCT IS SELECTED.
CLOSET
A-130B
15 SF
ELEC CLOSET
A-130A
20 SF
UTILITY CHASE
A-425
41 SF
DEDUCT ALT 2: ELIMINATE
THREE SEPARATE MEN'S
LOUNGE, WOMEN'S LOUNGE &
FAMILY VISITATION ROOMS AND
COMBINE INTO SINGLE SPACE.
THIS AREA BECOMES
STORAGE - ORDINARY HAZARD
GROUP 2.
A
B C D E 0.50.5
A.5
A.5
STAIR 2
S2-2
149 SF
LOGISTICS SUPPLY
A-210
126 SF
UNIT 7
A-209
120 SF
UNIT 8
A-207
135 SF
UNIT 9
A-206
116 SF
UNIT 10
A-204
124 SF
UNIT 11
A-203
124 SF
BARIATRIC UNIT 12
A-202
180 SF
SHARED BATH
A-205
89 SF
SHARED BATH
A-208
89 SF
PRIVATE BATH
A-211
88 SF
MED ROOM
A-227
115 SF
NURSE STATION
A-226
163 SF
STAFF TLT
A-225
54 SF
HAC
A-224
87 SF
ELEVATOR
A-002
89 SF
LINEN & SUPPLY STOR.
A-201
121 SF
BARIATRIC BATH
A-202A
91 SF
SECURE CORRIDOR
A-220
95 SF
UNIT 1
A-222
173 SF
SOILED UTILITY
A-419
98 SF
UNIT 2
A-221
144 SF
SHARED BATH
A-223
101 SF
TELECOM ROOM
A-219
93 SF
STAIR 1
S2-1
189 SF
SHARED BATH
A-214
102 SF
SHARED BATH
A-217
101 SF
UNIT 3
A-216
159 SF
UNIT 4
A-215
139 SF
UNIT 5
A-213
140 SF
UNIT 6
A-212
167 SF
CORRIDOR
A-252
322 SF
CORRIDOR
A-250
620 SF
CORRIDOR
A-251
603 SF
UTILITY ACCESS
A-421
77 SF
UTILITY CHASE
A-422
33 SF
A
B C D E 0.50.5
A.5
A.5
STAIR
2S-3
170 SF
MECHANICAL PENTHOUSE
A-300
1914 SF
ELEC ROOM
A-301
128 SF
EMERGENCY POWER
A-302
128 SF
FIRE PROTECTION SPRINKLER SYSTEM DESIGN CRITERIA
SPACE TYPE
HAZARD
CLASSIFICATION
DISCHARGE
DENSITY
MAXIMUM
COVERAGE
AREA PER
SPRINKLER
MAXIMUM
SPACING
SPRINKLER TYPE NOTES
GPM/FT² FT² FT.
GENERAL,
EXCEPT AS
LISTED BELOW
LIGHT HAZARD 0.10 225 15
SEMI-RECESSED
PENDENT, QUICK
RESPONSE, UL LISTED,
FM APPROVED
KITCHEN /
STORAGE, LINEN
ORDINARY
HAZARD
GROUP 2
0.20 130 15
SEMI-RECESSED
PENDENT OR UPRIGHT,
QUICK RESPONSE,
UL LISTED, FM APPROVED
EQUIPMENT
ROOM
ORDINARY
HAZARD
GROUP 1
0.15 130 15
QUICK RESPONSE
UPRIGHT, UL LISTED, FM
APPROVED
NOTES:
1. WATER DEMAND REQUIREMENTS ARE FOR HYDRAULIC CALCULATION METHOD. IF OTHER METHOD IS USED ADJUST
VALUES ACCORDING TO NFPA 13 REQUIREMENTS.
2. PROVIDE INTERMEDIATE TEMPERATURE SPRINKLER HEAD ONLY WITHIN ELEVATOR PIT IN ACCORDANCE WITH VA FIRE
PROTECTION DESIGN MANUAL.
HAZARD
SYMBOL
ELEVATOR
SHAFT
ORDINARY
HAZARD
GROUP 1
0.15 130 15
QUICK RESPONSE
UPRIGHT, UL LISTED, FM
APPROVED
1, 2
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
N
AREA B
KEY PLAN
AREA A
WORK AREA
EXISTING BUILDING
EXISTING BUILDING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
TRIPLE C - The A/E Group 100 Pearl Street, 14th floor Hartfort, CT 06103
(315) 484-5958 Mat Perkins
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP
MES GROUP
550 North Reo St, Suite 203 Tampa, FL 33609
(813) 289-4700 Nicholas Stephensen, P.E.
STRUCTURAL
C&S Companies 2575 E Camelback Rd, Suite 740 Phoenix, AZ 85016
(602) 997-7536 Bryan K. Salt, P.E. S.E.
B
IM
/4
-3
C o n s tr u c t S u b s ta n c e U s e
R e s id e n ti a l R e h a b
B u ild in g /4
-3
.A u g u s ta
.M E
P F
.R
.r v t
/2
/2
:4
:3
P
M
FX201
FIRE PROTECTION HAZARD CLASSIFICATION
PLANS
402-318
BLDG 258
07/26/2022 DCM/CB TH/DCM
100% CONSTRUCTION
DOCUMENTS ISSUED FOR
BIDDING
Construct Substance Use Residential Rehab Building
1 VA Center, Augusta, Maine
1/8" = 1'-0"
FIRE SPRINKLER ZONE PLAN - FIRST FLOOR
1/8" = 1'-0"
FIRE SPRINKLER ZONE PLAN - SECOND FLOOR
1/8" = 1'-0"
FIRE SPRINKLER ZONE PLAN - PENTHOUSE
DEDUCTIVE ALTERNATE LIST:
DEDUCT ALTERNATE 1: ELIMINATE CONNECTING
CORRIDOR. EXTERIOR PATHWAY ONLY.
DEDUCTIVE ALTERNATE 2: ELIMINATE THREE
SEPARATE MEN'S LOUNGE, WOMEN'S LOUNGE &
FAMILY VISITATION ROOMS AND COMBINE INTO
SINGLE SPACE.
Revisions: Date:
07/26/2022
GENERAL NOTES
1. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND INDICATIVE OF WORK TO BE PROVIDED (FURNISHED AND INSTALLED)
UNDER THIS CONTRACT. DRAWINGS SHOULD NOT BE SCALED.
2. THE CONTRACTOR IS RESPONSIBLE TO EXAMINE THE EXISTING CONDITIONS UNDER WHICH THEY SHALL OPERATE AND VERIFY
THE EXTENT OF WORK REQUIRED TO COMPLETE THE WORK UNDER THIS CONTRACT.
3. PRIOR TO ORDERING AND FABRICATING ANY EQUIPMENT, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EXAMINE THE PHYSICAL CONDITIONS AT THE PROJECT SITE AND VERIFY SPACE AND SUFFICIENT CLEARANCES ARE AVAILABLE FOR INSTALLING EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES, AND TO DETERMINE ANY NECESSARY MODIFICATIONS.
4. PERFORM ALL WORK IN COMPLIANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES, REGULATIONS, AND STANDARDS ADOPTED BY THE AUTHORITY HAVING JURISDICTION. IF CONFLICTS EXIST BETWEEN THESE ENGINEERING
DOCUMENTS AND CODES, THE MOST STRINGENT REQUIREMENTS SHALL GOVERN.
5. ALL CONSTRUCTION WORK SHALL ALSO MEET THE FOLLOWING CODE REQUIREMENTS:
• VA DESIGN MANUALS
• INTERNATIONAL BUILDING CODE (IBC) 2021
• INTERNATIONAL EXISTING BUILDING CODE 2021
• IBC MECHANICAL 2021
• IBC PLUMBING 2021
• IBC ENERGY CONSERVATION 2021
• ASHRAE 90.1-2013, ENERGY STANDARD FOR BUILDING EXCEPT LOW-RISE RESIDENTIAL BUILDINGS
• NFPA 1-2021, THE UNIFORM FIRE CODE
• NFPA 101-2021, THE LIFE SAFETY CODE
• NFPA 51B-2019, STANDARD FOR FIRE PREVENTION DURING WELDING, CUTTING AND OTHER HOT WORK
• NFPA 13-2019, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
• NFPA 70-2020, NATIONAL ELECTRICAL CODE
• NFPA 90A-2021, STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTING SYSTEMS.
• NFPA 99-2021, STANDARD FOR HEALTH CARE FACILITIES
• NFPA 241-2019, STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION AND DEMOLITION OPERATIONS.
6. CONTRACTOR SHALL COORDINATE AND SEQUENCE DEMOLITION, CLEANING, AND CONSTRUCTION WORK.
7. CONTRACTOR SHALL NOTE ANY SPECIAL REQUIREMENTS FOR INSTALLATION OF WORK UNDER THIS CONTRACT. DISMANTLE AND REASSEMBLE EQUIPMENT AS NECESSARY FOR ENTRY INTO THE BUILDING AND THE LOCATION OF INSTALLATION.
8. THE CONTRACTOR SHALL MAINTAIN A COMPLETE PROJECT SCHEDULE AND SHALL UPDATE THIS SCHEDULE WEEKLY. ANY
CHANGES SHALL BE NOTED AND AN UPDATED SCHEDULE SHALL BE PROVIDED TO THE OWNER.
9. ALL PERMITS, FEES, TAXES, ETC SHALL BE PAID BY CONTRACTOR AS PART OF THE TOTAL PROJECT COST.
10. MAINTAIN THE INTEGRITY OF ALL FIRE AND SMOKE RATED WALLS, PARTITIONS, CEILINGS, AND FLOORS. SEAL ALL PENETRATIONS THROUGH RATED ASSEMBLIES WITH FIRESTOP MATERIAL IN ACCORDANCE WITH U.L. REQUIREMENTS TO
MAINTAIN THE ASSEMBLY RATING.
11. CONTRACTOR SHALL FURNISH U.L. APPROVED DRAWINGS FOR EACH TYPE OF FIRE AND SMOKE RATED ASSEMBLY PENETRATION BY DUCTS, PIPES, OR CONDUITS, AND SHALL DISPLAY THESE DRAWINGS ON THE JOB SITE AT ALL TIMES
DURING CONSTRUCTION.
12. CONTRACTOR SHALL REFER TO ALL DETAILS FOR PROPER GUIDANCE.
13. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND EQUIPMENT SUBMITTALS FOR ALL PRODUCTS USED ON PROJECT.
14. THE ENGINEER'S APPROVAL OF SUBMITTAL DATA SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR DEVIATIONS FROM THE REQUIREMENTS OF CONTRACT DOCUMENTS UNLESS THE CONTRACTOR HAS RECEIVED WRITTEN APPROVAL FROM THE ENGINEER TO THE SPECIFIC DEVIATION. THE ENGINEER'S APPROVAL OF SUBMITTAL DATA SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR ERRORS OR OMISSIONS IN HIS OR HER SUBMITTAL DATA.
15. THE CONTRACTOR IS REQUIRED TO SUBMIT THREE COMPLETE O&M MANUALS IN THREE RING BINDERS AT SUBSTANTIAL COMPLETION. MANUALS SHALL INCLUDE INSTALLATION AND MAINTENANCE DATA ON ALL NEW EQUIPMENT AND MATERIALS, CERTIFIED TECHNICAL PRODUCT DATA, EQUIPMENT SHOP DRAWINGS, SPARE PARTS DATA, ETC. PROVIDE AN INDEX AND
ASSOCIATED DIVIDERS.
16. CLOSE OUT DOCUMENTS: THE CONTRACTOR IS TO MAINTAIN ONE SET OF CONSTRUCTION DRAWINGS ON SITE AND KEEP CURRENT WITH MARK UP AS-BUILT CONDITIONS DURING CONSTRUCTION OF THE PROJECT. THIS SET IS TO INCLUDE ALL CONTRACT CHANGES, MODIFICATIONS AND CLARIFICATIONS. THIS SET ALONG WITH ALL SHOP DRAWINGS SHALL BE TURNED OVER TO THE ARCHITECT/ENGINEER AFTER CONSTRUCTION COMPLETION. REFER TO SPECIFICATION SECTIONS 01 00 00 FOR
WARRANTY REQUIREMENTS AND 01 33 23 FOR SUBMITTAL REQUIREMENTS.
17. IT IS THE RESPONSIBILITY OF ALL BIDDERS TO THOROUGHLY REVIEW AND UNDERSTAND ALL CONSTRUCTION DOCUMENTS.
THIS INCLUDES BUT IS NOT LIMITED TO ALL DRAWINGS, SPECIFICATION SECTIONS, ETC. THE DRAWINGS ARE SCHEMATIC IN NATURE. THEREFORE BEFORE STARTING ANY WORK, THE CONTRACTOR SHALL REVIEW ALL OTHER CONSTRUCTION DOCUMENTS, VERIFY FIELD CONDITIONS AND SHALL MAKE ANY REQUIRED MINOR ADJUSTMENTS WITHOUT EXTRA COST TO THE OWNER. ANY MAJOR DISCREPANCIES FOUND SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER.
THE BASE BID SHALL REFLECT THE TOTAL COST OF NEW EQUIPMENT INSTALLATION. THIS INCLUDES LABOR, EQUIPMENT AND MATERIALS. NO CHANGE ORDERS SHALL BE ISSUED WITHOUT WRITTEN CONSENT AND APPROVAL FROM ENGINEER AND
ARCHITECT.
DRAWING KEYNOTE#
EQUIPMENT MARK
POINT OF NEW CONNECTION
LIMIT OF DEMOLITION
POINT OF CONNECTION TO CIVIL
PIPE RISER TAG
CW COLD WATER PIPING
HW HOT WATER PIPING
HWR HOT WATER RETURN PIPING
SAN SANITARY PIPING
V SANITARY VENT PIPING
PIPE UP
PIPE DOWN
GCO GRADE CLEAN OUT (1-WAY OR 2-WAY)OR
HOSE BIB WITH VACUUM BREAKER
OR VTR VENT THRU ROOF
WCO WALL CLEAN OUT
FCO FLOOR CLEAN OUT (1-WAY OR 2-WAY)OR
INVERT ELEVATIONIE
PIPE CAP
WCO
FLOOR DRAIN
BALL VALVE
BUTTERFLY VALVE
CHECK VALVE
GATE VALVE
PLUG VALVE
STRAINER
UNION
PRESSURE RELIEF VALVEPRV
BACKFLOW PREVENTER
FLOOR SINK
PLUMBING LEGEND
FD-C
FD-S
X-XX
CR COLD WATER RETURN PIPING
PLUMBING NOTES
1. REVIEW PLANS OF ALL TRADES PRIOR TO BIDDING AND BEGINNING WORK. INSTALLATIONS ARE TO INCLUDE ALL PLUMBING
FOR COMPLETE SYSTEMS SHOWN ON THE PLANS AND AS REQUIRED.
2. COORDINATE WITH OTHER TRADES TO PREVENT INTERFERENCE WITH HVAC DUCTS, STRUCTURE, ELECTRICAL, LIGHTING, AND OTHER PIPING IN THE CEILING SPACE. VENT PIPING AND WATER PIPING SHALL BE HELD EITHER ABOVE OR BELOW HVAC
DUCTWORK, AS COORDINATED WITH THE HVAC CONTRACTOR.
3. ALL CHANGES SHALL BE REVIEWED BY THE ARCHITECT.
4. COORDINATE WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING-IN PLUMBING FIXTURES AND EQUIPMENT SUPPLIES.
5. THE PLUMBING SUBCONTRACTOR SHALL FURNISH AND INSTALL ALL PLUMBING FIXTURES, UNLESS NOTED OTHERWISE.
6. VERIFY MOUNTING HEIGHT AND WATER CONNECTION SIZES OF ALL PLUMBING FIXTURES PRIOR TO ROUGH-IN. FURNISH CUT- OUT TEMPLATES, FOR PLUMBING FIXTURES TO BE INSTALLED IN MILLWORK, TO THE GENERAL CONTRACTOR.
7. MAKE PROPER HOT AND COLD WATER, WASTE AND VENT PIPING CONNECTIONS TO ALL FIXTURES AND EQUIPMENT EVEN
THOUGH ALL FITTINGS AND CONNECTIONS ARE NOT SHOWN ON DRAWINGS.
8. VERIFY LOCATION OF WATER SERVICE AND THE LOCATION/INVERTS OF SANITARY PIPING PRIOR TO INSTALLATION.
9. CUT AND PATCH CONCRETE AS REQUIRED.
10. IT IS NOT THE INTENT OF THESE DRAWINGS TO COVER ALL WORK AND MATERIAL. ANY EQUIPMENT, PLUMBING FIXTURE, TRIM HARDWARE AND/OR DEVICES USUALLY UTILIZED IN THE CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN ON THESE DRAWINGS, BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF THE WORK (AS DETERMINED BY THE ARCHITECT) SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AS PART OF HIS TOTAL WORK.
11. THE EQUIPMENT ROUGH-IN ITEMS AND THEIR DIMENSIONED LOCATIONS FOR ALL CONNECTIONS ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE. IN SOME INSTANCES THE OWNER OR SUPPLIER MAY MAKE SUBSTITUTIONS OR EQUIPMENT ITEMS MAY VARY FROM WHAT IS SHOWN. THEREFORE, THESE ITEMS AND DIMENSIONS SHALL BE VERIFIED WITH THE EQUIPMENT SUPPLIER, OWNER AND/OR EQUIPMENT ROUGH-IN DRAWING. FAILURE OF THE APPROPRIATE CONTRACTOR TO VERIFY ROUGH-INS OR THEIR LOCATIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION AND/OR
ADDITIONAL ROUGH-INS DIRECTLY UPON THAT CONTRACTOR.
12. CONTRACTOR SHALL SUPPLY TO THE ARCHITECT/ENGINEER THE REQUIRED COPIES OF SHOP DRAWINGS FOR APPROVAL SO THE QUALITY OF INTENDED MATERIALS OR EQUIPMENT CAN BE REVIEWED BEFORE INSTALLATION. THERE WILL BE NO INSTALLATION UNTIL SHOP DRAWINGS HAVE BEEN SUBMITTED AND REVIEWED BY THE ARCHITECT/ENGINEER.
13. DO NOT SCALE THIS DRAWING. REFER TO ARCHITECTURAL FLOOR PLAN FOR BUILDING DIMENSIONS.
14. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT NECESSARILY SHOW ALL ELBOWS, OFFSETS, UNIONS, VALVES, FITTINGS, ETC. REQUIRED TO COMPLETE THE INSTALLATION OF THE WORK. THE SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT THE CONTRACTOR HAS FAMILIARIZED HIMSELF WITH THE PLANS AND BUILDING SITE. CLAIMS MADE SUBSEQUENT TO THE PROPOSAL FOR MATERIALS AND LABOR BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE
RECOGNIZED IF THEY COULD HAVE BEEN FORESEEN HAD PROPER EXAMINATION BEEN MADE.
15. VERIFY SERVICE POINTS AND METERING LOCATIONS FOR PROJECTS WITH VA (DOMESTIC WATER, SANITARY SEWER, GAS, ETC.).
16. THE CONTRACTOR SHALL COOPERATE FULLY AMONG ALL TRADES.
17. ALL ROOF PENETRATIONS FOR ROOF DRAINS AND PLUMBING, GAS, AND REFRIGERANT PIPING SHALL BE MADE IN ACCORDANCE WITH ROOF SYSTEM MANUFACTURER'S GUIDELINES. COORDINATE WITH ARCHITECTURAL DETAILS AND/OR
MANUFACTURER FOR ROOF SYSTEM USED.
18. ALL PLUMBING VENTS IN EXTERIOR WALLS SHALL BE OFFSET A MINIMUM OF 3'-0" BEFORE ROOF PENETRATION.
19. INSTALL 1" INSULATION WITH ALL-SERVICE JACKET ON ALL ROOF LEADERS ABOVE CEILING.
20. THE WATER PIPING SYSTEM SHALL BE FLUSHED AND STERILIZED IN ACCORDANCE WITH LOCAL REGULATIONS.
21. HOT AND COLD WATER SUPPLY BRANCHES FOR ALL SYSTEMS HAVING QUICK CLOSING VALVES OF ANY TYPE SHALL HAVE WATER HAMMER ARRESTORS INSTALLED AT THE HIGH POINT ON THE END OF EACH BRANCH AND AS REQUIRED. SUPPLY
ACCESS DOORS IF SPACE IS NOT ACCESSIBLE.
22. ALL PIPES HANGING FROM SINGLE VERTICAL RODS / HANGERS SHALL NOT MOVE OR SWAY DURING OPERATION. SUITABLE
LATERAL SUPPORTS OR BRACING SHALL BE USED TO PREVENT SWAY OR MOVEMENT.
23. PROVIDE SHUTOFF BALL VALVES AND DIELECTRIC UNIONS FOR ALL EQUIPMENT HOT AND COLD WATER LINES. PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO EQUIPMENT. COORDINATE WITH EQUIPMENT SUPPLIER FOR EXACT
REQUIREMENTS.
24. VERIFY MOUNTING HEIGHTS OF ALL BARRIER FREE FIXTURES WITH ARCHITECTURAL PLANS.
25. PROVIDE COPPER INDIRECT WASTE PIPING REQUIRED FROM EQUIPMENT TO FLOOR DRAINS, OPEN RECEPTACLES, OR FLOOR SINKS. PIPING SHALL COMPLY WITH STATE AND LOCAL CODES. COORDINATE WITH ALL EQUIPMENT SUPPLIERS AND SIZES AS REQUIRED BY PIECE OF EQUIPMENT SERVED. HOLD PIPING TIGHT TO WALL WHERE APPLICABLE. PROPERLY SECURE AS REQUIRED. COORDINATE WITH CASEWORK SUPPLIER FOR MAXIMUM CLEARANCE UNDER CABINETS.
26. PROVIDE CHROME PLATED ESCUTCHEONS AT ALL WALL PENETRATIONS.
27. INSTALL STORM AND CONDENSATE PIPING WITH A MINIMUM SLOPE OF 1/8" PER FOOT. INSTALL SANITARY PIPING AS FOLLOWS:
LESS THAN 3" PIPING SHALL BE SLOPED AT 1/4" PER FOOT, 3 TO 6" PIPING SHALL BE SLOPED AT 1/8" PER FOOT, 8" AND LARGER SHALL BE SLOPED AT 1/16" PER FOOT. CONTRACTOR IS RESPONSIBLE FOR PROPER DRAINAGE OF ALL SYSTEMS.
28. ALL FLOOR DRAINS ARE TO BE PROVIDED WITH MINIMUM 3" DRAIN LINES, DEEP SEAL TRAPS, AND AUTOMATIC TRAP PRIMERS.
TRAP PRIMERS SHALL BE LOCATED IN A SERVICEABLE LOCATION AND INSTALLED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. HOLD TOP OF FLOOR DRAINS FLUSH WITH FINISHED FLOOR; SEE ARCHITECTURAL SHEETS FOR FLOOR
SLOPES AND PROPER FINISHED FLOOR ELEVATION.
29. ALL VENT PIPE TO BE COMPATIBLE WITH STRUCTURE, MECHANICAL EQUIPMENT, DUCTWORK, ELECTRICAL EQUIPMENT, AND LIGHTING. ALL VTR'S SHALL BE EXTENDED TO A MINIMUM OF 2" ABOVE PARAPET HEIGHT AND MAINTAINED 10'-0" MINIMUM
FROM ALL OUTSIDE AIR INTAKES.
30. MATERIALS, EQUIPMENT, ASSEMBLIES AND SYSTEMS SHALL MEET ALL PERTINENT REQUIREMENTS OF NATIONALLY RECOGNIZED TESTING ORGANIZATIONS SUCH AS UL, ASTM, ASSE, AWWE, AGA AND NFPA AS WELL AS THE MOST CURRENT
ADOPTED VERSION OF THE STATE AND LOCAL CODES.
31. ALL INSTALLED SYSTEMS, DEVICES AND RELATED ITEMS SHALL BE TESTED IN PLACE. REPLACE ANY AND ALL CONTRACTOR SUPPLIED DEFECTIVE DEVICES, ITEMS, OR SYSTEMS AT CONTRACTOR'S EXPENSE, BEFORE COMPLETION OF PROJECT.
32. WHERE JOB CONDITIONS REQUIRE CHANGES FROM THE CONTRACT DOCUMENTS THAT DO NOT CHANGE THE SCOPE OR NATURE OF WORK REQUIRED, THE CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT ADDITIONAL COST TO THE OWNER.
NO OTHER CHANGES MAY BE MADE WITHOUT WRITTEN PERMISSION FROM THE ENGINEER.
33. ALL EQUIPMENT, FIXTURES AND MATERIALS SHALL BE NEW AND UNUSED, AND INSTALLED IN STRICT CONFORMANCE TO MANUFACTURER'S RECOMMENDATIONS (UNLESS OTHERWISE NOTED). PROVIDE COMPLETE WITH ALL TRIM, STOPS, HANGERS, CARRIERS, SUPPORTS, ETC., INCLUDING PROVISIONS FOR BARRIER FREE USE, IF REQUIRED. WHERE FIXTURES ARE
ACCESSIBLE THEY MUST COMPLY WITH ALL FEDERAL ADA REGULATIONS.
34. CONTRACTOR SHALL GUARANTEE ALL WORK FOR WHICH MATERIALS ARE FURNISHED, FABRICATED, FIELD ERECTED, ALL FACTORY ASSEMBLED EQUIPMENT FOR WHICH NO SPECIFIC MANUFACTURER'S GUARANTEE IS FURNISHED, AND ALL WORK IN CONNECTION WITH INSTALLATION OF MANUFACTURER'S GUARANTEED EQUIPMENT. THE CONTRACTOR'S GUARANTEE SHALL LAST ONE YEAR FROM THE FINAL OWNER ACCEPTANCE OF THE WORK AND SHALL APPLY TO ALL DEFECTS IN MATERIALS AND
WORKMANSHIP OF ANY KIND.
35. ALL FAUCET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND NOT REQUIRE TIGHTGRASPING.
36. ALL BARRIER FREE WATER CLOSET CONTROLS SHALL BE LOCATED ON UNIT AWAY FROM CLOSEST WALL. VERIFY IF RIGHT OR
LEFT SIDE LOCATION.
(E) EXISTING
AFF ABOVE FINISHED FLOOR
BFF BELOW FINISHED FLOOR
CO PIPE CLEAN OUT
CP CIRCULATOR PUMP
CTE CONNECT TO EXISTING
CR COLD WATER RETURN
CW COLD WATER
DEMO DEMOLISH OR DEMOLITION
DFU DRAINAGE FIXTURE UNITS
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EXIST EXISTING
FCO FLOOR CLEAN OUT
FD FLOOR DRAIN
FS FLOOR SINK
G GAS
GCO GRADE CLEAN OUT
GPM GALLONS PER MINUTE
HB HOSE BIB
HD HUB DRAIN
HW HOT WATER
HWR HOT WATER RETURN
IB ICE MAKER OUTLET BOX
IBC INTERNATIONAL BUILDING CODE
IE INVERT ELEVATION
LAV LAVATORY
LP LIQUEFIED PETROLEUM GAS
MS MOP SINK
NC NORMALLY CLOSED
NG NATURAL GAS
NO NORMALLY OPEN
OD OVERFLOW ROOF DRAIN
OSD OVERFLOW (SECONDARY) STORM WATER DRAIN
PSD PRIMARY STORM WATER DRAIN
RD ROOF DRAIN
S SINK
SAN SANITARY
SH SHOWER
TWH TANKLESS WATER HEATER
VTR VENT THROUGH ROOF
W WASTE
WC WATER CLOSET
WCO WALL CLEAN OUT
WH WALL HYDRANT
WHA WATER HAMMER ARRESTOR
WSFU WATER SUPPLY FIXTURE UNITS
ABBREVIATIONS
PLUMBING ACCESSORIES
FD-S:
FLOOR SINK - REFER TO SPECIFICATION SECTION 22 13 00 FOR MORE INFORMATION. CONNECT TRAP TO FLOOR DRAIN.
TRAP PRIMER - REFER TO SPECIFICATION SECTION 22 13 00 FOR MORE INFORMATION.
FD-C
FLOOR DRAIN - REFER TO SPECIFICATION SECTION 22 13 00 FOR MORE INFORMATION. CONNECT TRAP PRIMER TO FLOOR
DRAIN.
TRAP PRIMER - REFER TO SPECIFICATION SECTION 22 13 00 FOR MORE INFORMATION.
WCO:
WALL CLEANOUT - REFER TO SPECIFICATION SECTION 22 14 00 FOR MORE INFORMATION.
GCO:
GRADE CLEANOUT - REFER TO SPECIFICATION SECTION 22 14 00 FOR MORE INFORMATION.
RD:
ROOF DRAIN - REFER TO SPECIFICATION SECTION 22 14 00 FOR MORE INFORMATION.
OD:
OVERFLOW (SECONDARY) ROOF DRAIN - REFER TO SPECIFICATION SECTION 22 14 00 FOR MORE INFORMATION.
DS:
DOWNSPOUT - REFER TO SPECIFICATION SECTION 22 14 00 FOR MORE INFORMATION.
1-1-GT:
GREASE TRAP - PDI-G101 SIZED FOR 10 GPM. REFER TO SPECIFICATION SECTION 22 13 23 FOR MORE INFORMATION.
1-1-ENC-GT:
ENCLOSURE - IN-FLOOR PIT ENCLOSURE, 30"L x 24"W x 30"D. PROVIDE WITH COMPOSITE LINER, STEEL SECURING RODS FOR INSTALLATION IN CONCRETE SLAB, ADJUSTABLE FRAME AND COVER. PROVIDE WITH BORDERLESS COVER, COORDINATE TILE COVERING THICKNESS WITH ARCHITECT. COVER SHALL BE MECHANICALLY FASTENED WITH VANDAL PROOF HARDWARE.
ENCLOSURE BASIS OF DESIGN IS CRAIGG MANUFACTURING MODEL ADL.
PLUMBING SHEET INDEX
PL001 PLUMBING LEGEND, NOTES, & ABBREVIATIONS
PL101 PLUMBING PLANS - FIRST FLOOR
PL102 PLUMBING PLANS - SECOND FLOOR
PL102.1 PLUMBING PLAN - SECOND FLOOR STORM DRAINAGE
PL103 PLUMBING PLAN - PENTHOUSE
PL104 PLUMBING PLAN - PENTHOUSE ROOF
PL501 PLUMBING DETAILS
PW301 WASTE & VENT RISER DIAGRAMS
PW302 DOMESTIC RISER DIAGRAM
PW303 STORM RISER DIAGRAM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
TRIPLE C - The A/E Group 100 Pearl Street, 14th floor Hartfort, CT 06103
(315) 484-5958 Mat Perkins
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP
MES GROUP
550 North Reo St, Suite 203 Tampa, FL 33609
(813) 289-4700 Nicholas Stephensen, P.E.
STRUCTURAL
C&S Companies 2575 E Camelback Rd, Suite 740 Phoenix, AZ 85016
(602) 997-7536 Bryan K. Salt, P.E. S.E.
B
IM
/4
-3
C o n s tr u c t S u b s ta n c e U s e
R e s id e n ti a l R e h a b
B u ild in g /4
-3
.A u g u s ta
.M E
P F
.R
.r v t
/2
/2
:4
:0
P
M
PL001
PLUMBING LEGEND, NOTES, & ABBREVIATIONS 402-318
BLDG 258
07/26/2022 DCM/CB TH/DCM
100% CONSTRUCTION
DOCUMENTS ISSUED FOR
BIDDING
Construct Substance Use Residential Rehab Building
1 VA Center, Augusta, Maine
PLUMBING FIXTURE SCHEDULE
FIXTURE
MARK
FIXTURE DESCRIPTION
ROUGH-IN PIPE SIZES FIXTURE UNITS BASIS OF DESIGN
COLD
WATER
SUPPLY
HOT
WATER
SUPPLY
FIXTURE
TRAP
FIXTURE
DRAIN
COLD
WATER
HOT
WATER
DRAINAGE MANUFACTURER MODEL NUMBER
P-103
WATER CLOSET - WALL HUNG -
ADA. AUTO FLUSH VALVE, HARD
WIRED, PROVIDE WITH
TRANSFORMER. REFER TO
SPECIFICATION SECTION 22 40
00 FOR MORE INFORMATION.
1" N/A 4" 4" 10 0 4 ZURN, ZURN, ZURN, SLOAN, SLOAN
Z1201-N_4, Z5615-BWL, Z5950,
ROYAL 111-ESS
HARDWIRED-1.28-YO-TMO-HW,
034515PK EL-154
P-114
WATER CLOSET - WALL HUNG -
ADA REFER TO SPECIFICATION
SECTION 22 40 00 FOR MORE
INFORMATION.
1" N/A 4" 4" 10 0 4 METCRAFT, SLOAN ROYAL 4675, 111-1.6-YO
P-418
LAVATORY - WALL HUNG - ADA,
AUTO FAUCET, HARD WIRED,
PROVIDE WITH TRANSFORMER.
PROVIDE WITH ASSE-1070
THERMOSTATIC MIXING VALVE.
REFER TO SPECIFICATION
SECTION 22 40 00 FOR MORE
INFORMATION.
1/2" 1/2" 1 1/4" 2" 1.5 1.5 2
ZURN, KOHLER, TRUEBRO,
AMERICAN STANDARD, AMERICAN
STANDARD, CHICAGO FAUCETS
Z1231, K-2054, 103 E-Z, NEXTGEN
SELECTRONIC 775B.315, NEXTGEN
SLECTRONIC PK00.HAC,
131-CFMAB
P-502
JANITOR SINK. REFER TO
SPECIFICATION SECTION 22 40
00 FOR MORE INFORMATION.
1/2" 1/2" 3" 3" 2.25 2.25 2 FIAT, CHICAGO FAUCET TSBCR, 540-LD897SWXF204CP
P-505
CLINICAL SINK, FLOOR
MOUNTED, WITH SERVICE
FAUCET REFER TO
SPECIFICATION SECTION 22 40
00 FOR MORE INFORMATION.
1/2" 1/2" 3" 3" 3 3 2
ZURN, KOHLER, CHICAGO FAUCETS,
SLOAN ROYAL, CHICAGO FAUCET
Z1217, CAMERTON K-12867,
814-VBCP, ROYAL 310-6.5,
910-G777-19KCP
P-528
SINGLE COMPARTMENT SINK -
COUNTER. REFER TO
SPECIFICATION SECTION 22 40
00 FOR MORE INFORMATION.
1/2" 1/2" 1 1/2" 2" 1.5 1.5 2
JUST MANUFACTURING COMPANY,
CHICAGO FAUCET, JUST
MANUFACTURING COMPANY,
CHICAGO FAUCETS
SL-ADA-2122-A-GR,
1102-GN8AE3-317AB, J-35,
131-CFMAB
P-604
WATER COOLER. REFER TO
SPECIFICATION SECTION 22 40
00 FOR MORE INFORMATION.
1/2" N/A 1 1/4" 2" 0.25 0 0.5 ELKAY LZWS-LRPBM8K
P-701
SHOWER STALL - ADA. REFER TO
SPECIFICATION SECTION 22 40
00 FOR MORE INFORMATION.
1/2" 1/2" 1 1/4" 2" 3 3 2 CHICAGO FAUCETS, JOSAM SH-PB1-11-044, 46200
P-708
EMERGENCY EYE/FACE WASH -
WALL MOUNTED, PROVIDE WITH
ASSE-1071 THERMOSTATIC
MIXING VALVE. REFER TO
SPECIFICATION SECTION 22 40
00 FOR MORE INFORMATION.
1/2" 1/2" 1 1/2" 2" 1 1 2 GUARDIAN, GUARDIAN G1750, G6024
P-808
WASHING MACHINE OUTLET BOX.
REFER TO SPECIFICATION
SECTION 22 40 00 FOR MORE
INFORMATION.
1/2" 1/2" 1 1/4" 2" 2.25 2.25 3 GUY GRAY 82327
P-812
ICE MAKER OUTLET BOX. REFER
TO SPECIFICATION SECTION 22
40 00 FOR MORE INFORMATION.
1/2" N/A N/A N/A 0.25 0 3 GUY GRAY 88164
CIRCULATOR PUMP SCHEDULE
MARK CAPACITY TOTAL HEAD SHUTOFF HEAD MOTOR POWER
ELECTRICAL DATA BASIS OF DESIGN
NOTES
VOLTAGE PHASE MANUFACTURER
MODEL
NUMBER
1-3-CPC01 4.0 GPM 24 ftH2O 35 ftH2O 0.125 hp 115 V 1 TACO 009-SF5 1
1-3-CPH01 4.0 GPM 24 ftH2O 35 ftH2O 0.125 hp 115 V 1 TACO 009-SF5 1
THERMOSTATIC MIXING STATION SCHEDULE
MARK CAPACITY
ELECTRICAL DATA BASIS OF DESIGN
NOTES
VOLTAGE PHASE MANUFACTURER MODEL NUMBER
1-3-TMV01 60.0 GPM 115 V 1 POWERS / WATTS LFIS150CFSLP+ 1-6
NOTES:
1. PROVIDE ELECTRICAL CONNECTION TO THERMOSTATIC MIXING STATION, CIRCULATOR PUMP SHALL BE CONTROLLED BY
THERMOSTATIC MIXING STATION.
NOTES:
1. PROVIDE AS PRE-PIPED SYSTEM MOUNTED ON UNISTRUT. PROVIDE ALL ADDITIONAL MOUNTING STRUCTURE
REQUIRED.
2. PROVIDE CONTROLS WITH BACNET GATEWAY FOR INTEGRATION WITH FACILITY BUILDING AUTOMATION
SYSTEM.
3. DISCHARGE OF MIXING STATION SHALL BE SET TO 140°F (ADJ.) UNDER NORMAL OPERATION.
4. PROVIDE WITH ABILITY TO OVERRIDE OUTLET TEMPERATURE SETTINGS TO DISCHARGE 180°F FOR THERMAL
ERADICATION.
5. PROVIDE WITH INLET AND OUTLET TEMPERATURE SENSORS THAT CAN REPORT READINGS TO BUILDING
AUTOMATION SYSTEM.
6. WIRE MIXING STATION CONTROLS TO POWER AND CONTROL CIRCULATOR PUMP TO MAINTAIN HOT WATER
DISCHARGE AND HOT WATER RETURN TEMPERATURE DIFFERENTIAL OF ~2°F (ADJ.).
REVERSE OSMOSIS FILTER SCHEDULE
MARK SYSTEM
BASIS OF DESIGN MAXIMUM FLOW
RATE
SYSTEM
CAPACITY (GPD)
PUMP MOTOR
HP
MCA MOCP PHASE VOLTAGE NOTES
MANUFACTURER MODEL NO.
1-3-ROF01 HYDRONIC US WATER AR-4-1000 4.0 GPM 1000.0 1/2 8.2 A 15.0 A 1 120 V 1-2
ELEVATOR SUMP PUMP SCHEDULE
MARK SYSTEM
BASIS OF DESIGN PUMP FLOW
RATE
PUMP HEAD (FT)
PUMP MOTOR
HP
FLA PHASE VOLTAGE NOTES
MANUFACTURER MODEL NO.
1-1-ESP01
ELEVATOR SUMP
PUMP
LIBERTY PUMPS ELV280 50.0 GPM 14.0 1/2 8.5 A 1 120 V 1-5
NOTES:
1. PROVIDE SUMP PUMP SYSTEM WITH OIL DETECTION THAT DE-ENERGIZES PUMP WHEN OIL OR HYDRAULIC FLUID IS DETECTED.
2. PROVIDE WITH FLOAT SWITCH.
3. PROVIDE WITH PUMP CONTROLLER.
4. PROVIDE WITH REMOTE ALARM.
5. PROVIDE SIGNAL FROM PUMP CONTROLLER TO ALERT BUILDING AUTOMATION SYSTEM ON HIGH LEVEL, OIL DETECTION, OR PUMP FAILURE.
NOTES:
1. PROVIDE FULLY PACKAGED, INLINE REVERSE OSMOSIS FILTER SYSTEM.
2. PROVIDE WITH STAINLESS STEEL PUMP.
P-528 P-103
P-418
P-808
P-808
P-418 P-808
P-808
P-528
P-103
P-418
P-103
P-528
STAIR 2
S2-1
STAFF BREAK
A-109
MULTIPURPOSE
A-108
OFFICE 2
A-113
OFFICE 3
A-111
OFFICE 1
A-112
CORRIDOR
A-131
SHARED LAUNDRY
A-114
EXAM RM
A-106
UDS TLT
A-105
MULTIPURPOSE
A-107
STAFF TLT
A-110
REC ROOM & KITCHEN
A-103
RECEPTION
A-102
ELEVATOR
A-001
MEN'S LOUNGE
A-115
WOMEN'S LOUNGE
A-116
FAMILY VISITATION
A-117
STAIR 1
S1-1
TELECOM ROOM
A-119
HAC
A-118
FIRE RISER ROOM
A-120
CLOSET
A-101A
VESTIBULE
A-100
WAITING
A-101
4 4
A
A
B
B
C
C
D
D E
E 0.50.5
A.5
P-418
P-418
P-418
P-812
P-812
1 1/4" CW
1 1/4" HW
1/2" HW-R
1/2" CR
1/2" CR
3/4" CW
1/2" HW
1/2" HW-R
3/4" HW
1/2" CR1/2" HW-R
1 1/2" CW
3/4" HW
1/2" CR 1/2" HW
1 1/2" CW
1" HW
1/2" HW-R 1/2" CR
1 1/2" CW
1/2" HW
3" CW
P-502
1" CW
1" HW
2" CW
1" HW
1 1/2" CW
1 1/2" HW
2" CW
DEDUCT ALT 1: ELIMINATE CONNECTING CORRIDOR.
EXTERIOR PATHWAY ONLY.
NO CHANGE TO DOMESTIC WATER SCOPE OR WORK.
P-604
P-812
P-812
DEDUCT ALT 2: ELIMINATE
THREE SEPARATE MEN'S
LOUNGE, WOMEN'S LOUNGE &
FAMILY VISITATION ROOMS AND
COMBINE INTO SINGLE SPACE.
DOMESTIC WATER PIPING
SHALL BE ROUGHED IN 6"
BEYOND ISOLATION VALVES AT
CORRIDOR WALL.
P-812 P-812
CORRIDOR
A-133
PUBLIC TLT
A-104
4" SS
P-528
P-103
P-418
P-808
P-808 P-418
P-808
P-808
P-528
P-103
P-418
P-103
P-528
STAIR 2
S2-1
STAFF BREAK
A-109
MULTIPURPOSE
A-108
OFFICE 2
A-113
OFFICE 3
A-111
OFFICE 1
A-112
CORRIDOR
A-131
SHARED LAUNDRY
A-114
EXAM RM
A-106
UDS TLT
A-105
MULTIPURPOSE
A-107
STAFF TLT
A-110
REC ROOM & KITCHEN
A-103
RECEPTION
A-102
ELEVATOR
A-001
MEN'S LOUNGE
A-115
WOMEN'S LOUNGE
A-116
FAMILY VISITATION
A-117
STAIR 1
S1-1
TELECOM ROOM
A-119
HAC
A-118
FIRE RISER ROOM
A-120
CLOSET
A-101A
VESTIBULE
A-100
WAITING
A-101
4" SS
4" SS
4" SS
3" SS
4 4
A
A
B
B
C
C
D
D E
E 0.5
A.5
P-418
P-418
P-418
P-502
1-1-ESP01
1 1/2" PD
1 1/2" PD
4" FCO
3" SD
3" OSD
4" SD
2" SD
3" SD 3" OSD5
2" OSD
DEDUCT ALT 1: ELIMINATE CONNECTING CORRIDOR.
EXTERIOR PATHWAY ONLY.
REPLACE FLOOR CLEANOUT WITH GRADE CLEANOUT
IN SIDEWALK.
2" FD-C
P-604
3" OSD
3" SD
4" SS
DEDUCT ALT 2: ELIMINATE THREE
SEPARATE MEN'S LOUNGE, WOMEN'S
LOUNGE & FAMILY VISITATION ROOMS
AND COMBINE INTO SINGLE SPACE.
STORMWATER PIPING AND SANITARY
PIPING FROM ABOVE SHALL BE
INSTALLED AS SHOWN ON PLAN AND
SANITARY PIPING SHALL BE ROUGHED
IN TO ACCOMMODATE FUTURE
CONNECTION TO SINK P-528.
FD-S
P-812
P-812
3" FCO
1-1-GT 20
FD-S 21
1-1-ENC-GT 22
2" SS 1 1/2" V
1 1/2" V
PLUMBING SHEET NOTES
A THIS PLAN IS DIAGRAMMATIC IN NATURE AND SHALL NOT BE SCALED TO
DETERMINE THE LOCATION OR DIMENSION OF THE WORK. CONTRACTOR SHALL
VERIFY EXACT LOCATION OF PIPING AND PENETRATIONS.
B CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THE LOCATION OF EXISTING
BELOW GRADE WASTE PIPING AND REFLECT ANY DEVIATION GREATER THAN 1'-0"
FROM THIS PLAN ON THE AS-BUILT DRAWINGS.
C CUTTING, BORING, SAWCUTTING OR DRILLING THROUGH THE NEW AND EXISTING
STRUCTURAL ELEMENTS TO BE DONE ONLY WHEN DETAILED IN THE DRAWINGS
OR ACCEPTED BY THE APPROVAL THE STRUCTURAL ENGINEER AND VA.
D REPAIR WALL SURFACE AFTER INSTALLATION AND INSPECTION OF EACH
PLUMBING FIXTURE AND PIPING INSTALLED.
E ALL WALL-MOUNTED ACCESS PANELS SHALL BE LOCKABLE TYPE.
F MAINTAIN MINIMUM 10-0" SEPARATION BETWEEN FLUE AND PLUMBING VENT
OUTLETS AND ANY FRESH AIR INTAKE. COORDINATE WITH HVAC CONTRACTOR.
G FLOORS SHALL SLOPE TO DRAINS AT 1% MINIMUM SLOPE. SEE ARCHITECTURAL
PLANS FOR MORE INFORMATION.
H PROVIDE ALL FLOOR DRAINS, FLOOR SINKS, TRENCH DRAINS, ETC. WITH TRAP
GUARD DEVICES (ASSE 1072 COMPLIANT).
I PROVIDE WALL CLEAN OUTS IN ALL VENT RISERS ON BRANCHES LONGER THAN
5'-0" AND ON BRANCHES SERVING SINKS OR URINALS.
J SEE RISER DIAGRAMS FOR PIPE SIZING.
N
AREA B
KEY PLAN
WORK AREA
EXISTING BUILDING
EXISTING BUILDING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
TRIPLE C - The A/E Group 100 Pearl Street, 14th floor Hartfort, CT 06103
(315) 484-5958 Mat Perkins
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP
MES GROUP
550 North Reo St, Suite 203 Tampa, FL 33609
(813) 289-4700 Nicholas Stephensen, P.E.
STRUCTURAL
C&S Companies 2575 E Camelback Rd, Suite 740 Phoenix, AZ 85016
(602) 997-7536 Bryan K. Salt, P.E. S.E.
B
IM
/4
-3
C o n s tr u c t S u b s ta n c e U s e
R e s id e n ti a l R e h a b
B u ild in g /4
-3
.A u g u s ta
.M E
P F
.R
.r v t
/2
/2
:4
:1
P
M
PL101
PLUMBING PLANS - FIRST FLOOR 402-318
BLDG 258
07/26/2022 DCM/CB TH/DCM
100% CONSTRUCTION
DOCUMENTS ISSUED FOR
BIDDING
Construct Substance Use Residential Rehab Building
1 VA Center, Augusta, Maine
1/8" = 1'-0"
LEVEL 1 PLUMBING PLAN - DOMESTIC WATER PIPING
1/8" = 1'-0"
LEVEL 1 PLUMBING PLAN - SANITARY & VENT PIPING
KEYNOTES
1 3" DOMESTIC COLD WATER PIPING. REFER TO CIVIL FOR CONTINUATION.
2 CW, HW, CWR, AND HWR, DOWN FROM SECOND FLOOR.
3 3" DOMESTIC COLD WATER PIPING UP TO PENTHOUSE ON THIRD LEVEL. REFER TO
PL103 FOR CONTINUATION.
4 PRIMARY STORM DRAINAGE. REFER TO CIVIL FOR CONTINUATION.
5 OVERFLOW STORM DRAINAGE. TERMINATE 18" ABOVE GRADE WITH DOWNSPOUT.
6 SANITARY PIPING DOWN FROM SECOND FLOOR.
7 4" SANITARY PIPING TO GRADE CLEANOUT AT AN INVERT ELEVATION OF 165.17'.
REFER TO CIVIL UTILITY PLANS FOR CONTINUATION.
8 PUMPED DRAIN FROM ELEVATOR SUMP PUMP 1-1-ESP01. TERMINATE PIPE 18"
ABOVE GRADE.
9 PUMPED DRAIN FROM ELEVATOR SUMP PUMP UP TO ABOVE FIRST FLOOR
CEILING.
10 MECHANICAL CONDENSATE PIPING. ROUTE PIPING TO FLOOR DRAIN LOCATED IN
FIRE RISER ROOM.
11 PROVIDE CAP ON END OF SANITARY PIPING. CONTRACTOR SHALL LEAVE A
MINIMAL LENGTH DEAD-HEAD TO ALLOW FOR CONNECTION OF FUTURE BUILDING
EXPANSION.
12 IF DEDUCTIVE ALTERNATE #1 IS SELECTED, NOTED FLOOR CLEANOUT SHALL BE
REPLACED WITH A GRADE CLEANOUT.
13 PROVIDE FIXTURES IN UDS TOILET ROOM WITH CONTROLS AS SHOWN IN UDS
TOILET FIXTURE CONTROL DETAIL ON SHEET PL501, FIXTURES SHALL HAVE THE
ABILITY TO BE TURNED ON/OFF WITH A REMOTE LOCATED SWITCH. LOCATE
SWITCH IN EXAM ROOM A-106.
14 2.5" VENT PIPING UP TO SECOND FLOOR.
15 OVERFLOW STORM DRAINAGE DOWN FROM SECOND FLOOR. PIPING LOCATED IN
FIRST FLOOR CEILING.
16 PRIMARY STORM DRAINAGE DOWN FROM SECOND FLOOR. PIPING LOCATED IN
FIRST FLOOR CEILING.
17 ICE BOX HOOKUP LOCATED BEHIND LOWER CABINET.
18 STORM DRAINAGE PIPING DOWN FROM SECOND FLOOR. PIPE TO RUN IN FIRST
FLOOR CEILING BELOW BEAM AND INTO CHASE.
19 PROVIDE FUR OUT FOR STORM PIPING. TYP.
20 ROUTE SANITARY WASTE PIPING FROM KITCHEN SINK TO IN-FLOOR GREASE TRAP
AND ROUTE DISCHARGE FROM GREASE TRAP TO SANITARY PIPING. GREASE TRAP
SHALL BE PROVIDED WITH PDI-G101 REQUIRED FLOW CONTROL VALVE AND SIDE
DISCHARGE KIT.
21 PROVIDE FLOOR SINK WITHIN CASEWORK TO RECEIVE DRAIN FROM COUNTERTOP
MOUNTE ICE MAKER.
22 PROVIDE GREASE TRAP WITHIN IN-FLOOR PIT ENCLOSURE. ALL PENETRATIONS
THROUGH ENCLOSURE WALLS SHALL BE SEALED. PROVIDE FILL WITHIN
ENCLOSURE TO SUPPORT GREASE TRAP ACCORDING TO MANUFACTURERS
RECCOMMENDATIONS.
23 PROVIDE 3" BACKFLOW PREVENTER IN INCOMING WATER SERVICE PIPING.
24 PROVIDE DOMESTIC WATER SUBMETER AS DESCRIBED IN SPECIFICATION
SECTION 25 10 10 ADVANCED UTILITY METERING. SUBMETER SHALL BE
INTEGRADTED WITH BUILDING AUTOMATION SYSTEM.
DEDUCTIVE ALTERNATE LIST:
DEDUCT ALTERNATE 1: ELIMINATE CONNECTING
CORRIDOR. EXTERIOR PATHWAY ONLY.
DEDUCTIVE ALTERNATE 2: ELIMINATE THREE
SEPARATE MEN'S LOUNGE, WOMEN'S LOUNGE &
FAMILY VISITATION ROOMS AND COMBINE INTO
SINGLE SPACE.
Revisions: Date:
DRAWING KEYNOTE#
EQUIPMENT MARK
CW COLD WATER PIPING
HW HOT WATER PIPING
HWR HOT WATER RETURN PIPING
SAN SANITARY PIPING
V SANITARY VENT PIPING
PIPE UP
PIPE DOWN
GCO GRADE CLEAN OUT (1-WAY OR 2-WAY)OR
HOSE BIB WITH VACUUM BREAKER
OR VTR VENT THRU ROOF
WCO WALL CLEAN OUT
FCO FLOOR CLEAN OUT (1-WAY OR 2-WAY)OR
PIPE CAP
WCO
FLOOR DRAIN
BALL VALVE
BACKFLOW PREVENTER
FLOOR SINK
PLUMBING LEGEND
FD-C
FD-S
X-XX
CR COLD WATER RETURN PIPING
FIXTURE SCHEDULE
FIXTURE MARK FIXTURE DESCRIPTION
P-103
WATER CLOSET - WALL HUNG - ADA. AUTO FLUSH VALVE,
HARD WIRED, PROVIDE WITH TRANSFORMER. REFER TO
SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-114
WATER CLOSET - WALL HUNG - ADA REFER TO
SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-418
LAVATORY - WALL HUNG - ADA, AUTO FAUCET, HARD
WIRED, PROVIDE WITH TRANSFORMER. PROVIDE WITH
ASSE-1070 THERMOSTATIC MIXING VALVE. REFER TO
SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-502
JANITOR SINK. REFER TO SPECIFICATION SECTION 22 40 00
FOR MORE INFORMATION.
P-505
CLINICAL SINK, FLOOR MOUNTED, WITH SERVICE FAUCET
REFER TO SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-528
SINGLE COMPARTMENT SINK - COUNTER. REFER TO
SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-604
WATER COOLER. REFER TO SPECIFICATION SECTION 22 40
00 FOR MORE INFORMATION.
P-701
SHOWER STALL - ADA. REFER TO SPECIFICATION SECTION
22 40 00 FOR MORE INFORMATION.
P-708
EMERGENCY EYE/FACE WASH - WALL MOUNTED, PROVIDE
WITH ASSE-1071 THERMOSTATIC MIXING VALVE. REFER TO
SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-808
WASHING MACHINE OUTLET BOX. REFER TO
SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-812
ICE MAKER OUTLET BOX. REFER TO SPECIFICATION
SECTION 22 40 00 FOR MORE INFORMATION.
P-418
P-103
P-418 P-418
P-114
P-418
P-103
P-418
P-103
P-103 P-418
P-103
P-418
P-103
P-418
STAIR 2
S2-2
LOGISTICS SUPPLY
A-210
UNIT 7
A-209
UNIT 8
A-207
UNIT 9
A-206
UNIT 10
A-204
UNIT 11
A-203
BARIATRIC UNIT 12
A-202
BARIATRIC BATH
A-202A
SHARED BATH
A-205
SHARED BATH
A-208
PRIVATE BATH
A-211
MED ROOM
A-227
NURSE STATION
A-226
STAFF TLT
A-225
HAC
A-224
ELEVATOR
A-002
LINEN & SUPPLY STOR.
A-201
UNIT 1
A-222
SECURE CORRIDOR
A-220
UNIT 2
A-221
SOILED UTILITY
A-419
SHARED BATH
A-223
TELECOM ROOM
A-219
STAIR 1
S2-1
CORRIDOR
A-250
UNIT 6
A-212
UNIT 5
A-213
UNIT 4
A-215
UNIT 3
A-216
SHARED BATH
A-217
SHARED BATH
A-214
P-701
P-701
P-701
P-701
P-701P-701
4 4
A
A
B
B
C
C
D
D E
E 0.50.5
A.5
A.5
P-418
P-502
P-418
P-505
P-418
P-701
P-103
1 1/4" HW
2" CW
1/2" HW-R
1/2" CR
1 1/2" HW2 1/2" CW
1/2" HW
1" CW
1/2" CR
1/2" HW-R
1 1/4" HW 2" CW1" HW2" CW
1/2" HW
1/2" CW
1/2" CR
1/2" HW-R
1/2" HW
1/2" CW
3/4" HW
1 1/2" CW
1/2" HW 1 1/2" CW
3/4" HW
1 1/2" CW
1/2" CW
1" CW
1/2" HW
UTILITY ACCESS
A-4212
P-708
1/2" HW-R
1 1/2" HW
2" CW
P-418
P-103
P-418 P-418
P-114
P-418
P-103
P-418
P-103
P-103
P-418
P-103
P-418
P-103
P-418
P-701
P-701
P-701
P-701
P-701P-701
STAIR 2
S2-2
LOGISTICS SUPPLY
A-210
UNIT 7
A-209
UNIT 8
A-207
UNIT 9
A-206
UNIT 10
A-204
UNIT 11
A-203
BARIATRIC UNIT 12
A-202
BARIATRIC BATH
A-202A
SHARED BATH
A-205
SHARED BATH
A-208
PRIVATE BATH
A-211
MED ROOM
A-227 NURSE STATION
A-226
STAFF TLT
A-225
HAC
A-224
ELEVATOR
A-002
CORRIDOR
A-250
LINEN & SUPPLY STOR.
A-201
UNIT 1
A-222
SECURE CORRIDOR
A-220
UNIT 2
A-221
SOILED UTILITY
A-419
SHARED BATH
A-223
TELECOM ROOM
A-219
STAIR 1
S2-1
UNIT 6
A-212
UNIT 5
A-213
UNIT 4
A-215
UNIT 3
A-216
SHARED BATH
A-217
SHARED BATH
A-214
4 4
A
A
B
B
C
C
D
D E
E 0.50.5
A.5
A.5
P-418
P-418
P-502
P-418
P-505
4" SS
P-701
P-103
2" V
4" SS
2" V
2" V
3" SS
4" SS
2" SS
2" SS
1 1/2" V
2" SS
2" SS
2" SS
4" SS
2" SS
3" SS
2" SS
4" SS
2" SS
UTILITY ACCESS
A-421
3" VTR
3" VTR
3" VTR
1 1/2" V1 1/2" V
2" V
2" SS 2" V
P-708
4" SS
4" SS
PLUMBING SHEET NOTES
A THIS PLAN IS DIAGRAMMATIC IN NATURE AND SHALL NOT BE SCALED TO
DETERMINE THE LOCATION OR DIMENSION OF THE WORK. CONTRACTOR SHALL
VERIFY EXACT LOCATION OF PIPING AND PENETRATIONS.
B CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THE LOCATION OF EXISTING
BELOW GRADE WASTE PIPING AND REFLECT ANY DEVIATION GREATER THAN 1'-0"
FROM THIS PLAN ON THE AS-BUILT DRAWINGS.
C CUTTING, BORING, SAWCUTTING OR DRILLING THROUGH THE NEW AND EXISTING
STRUCTURAL ELEMENTS TO BE DONE ONLY WHEN DETAILED IN THE DRAWINGS
OR ACCEPTED BY THE APPROVAL THE STRUCTURAL ENGINEER AND VA.
D REPAIR WALL SURFACE AFTER INSTALLATION AND INSPECTION OF EACH
PLUMBING FIXTURE AND PIPING INSTALLED.
E ALL WALL-MOUNTED ACCESS PANELS SHALL BE LOCKABLE TYPE.
F MAINTAIN MINIMUM 10-0" SEPARATION BETWEEN FLUE AND PLUMBING VENT
OUTLETS AND ANY FRESH AIR INTAKE. COORDINATE WITH HVAC CONTRACTOR.
G FLOORS SHALL SLOPE TO DRAINS AT 1% MINIMUM SLOPE. SEE ARCHITECTURAL
PLANS FOR MORE INFORMATION.
H PROVIDE ALL FLOOR DRAINS, FLOOR SINKS, TRENCH DRAINS, ETC. WITH TRAP
GUARD DEVICES (ASSE 1072 COMPLIANT).
I PROVIDE WALL CLEAN OUTS IN ALL VENT RISERS ON BRANCHES LONGER THAN
5'-0" AND ON BRANCHES SERVING SINKS OR URINALS.
J SEE RISER DIAGRAMS FOR PIPE SIZING.
N
AREA B
KEY PLAN
WORK AREA
EXISTING BUILDING
EXISTING BUILDING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
TRIPLE C - The A/E Group 100 Pearl Street, 14th floor Hartfort, CT 06103
(315) 484-5958 Mat Perkins
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP
MES GROUP
550 North Reo St, Suite 203 Tampa, FL 33609
(813) 289-4700 Nicholas Stephensen, P.E.
STRUCTURAL
C&S Companies 2575 E Camelback Rd, Suite 740 Phoenix, AZ 85016
(602) 997-7536 Bryan K. Salt, P.E. S.E.
B
IM
/4
-3
C o n s tr u c t S u b s ta n c e U s e
R e s id e n ti a l R e h a b
B u ild in g /4
-3
.A u g u s ta
.M E
P F
.R
.r v t
/2
/2
:4
:2
P
M
PL102
PLUMBING PLANS - SECOND FLOOR 402-318
BLDG 258
07/26/2022 DCM/CB TH/DCM
100% CONSTRUCTION
DOCUMENTS ISSUED FOR
BIDDING
Construct Substance Use Residential Rehab Building
1 VA Center, Augusta, Maine
1/8" = 1'-0"
LEVEL 2 PLUMBING PLAN - DOMESTIC WATER PIPING
1/8" = 1'-0"
LEVEL 2 PLUMBING PLAN - SANITARY & VENT PIPING
KEYNOTES
1 SANITARY PIPING DOWN TO FIRST FLOOR.
2 3" CW UP TO PENTHOUSE ON THIRD LEVEL FROM FLOOR BELOW.
3 2 1/2" VENT UP FROM FIRST FLOOR.
4 3" SANITARY DOWN FROM FLOOR DRAIN LOCATED IN PENTHOUSE.
5 SANITARY PIPING LOCATED IN CEILING OF SECOND FLOOR. COORDINATE WITH
OTHER TRADES.
6 MECHANICAL CONDENSATE PIPING. ROUTE PIPING DOWN TO FIRST FLOOR AND
CONNECT INTO FIRST FLOOR CONDENSATE PIPING.
7 PROVIDE VENT PIPING UP TO VENT THROUGH ROOF ABOVE.
8 CW, HW, CWR, AND HWR PIPING DOWN TO FIRST FLOOR.
9 CW, HW, CWR, AND HWR PIPING UP TO PENTHOUSE ABOVE.
Revisions: Date:
DRAWING KEYNOTE#
EQUIPMENT MARK
CW COLD WATER PIPING
HW HOT WATER PIPING
HWR HOT WATER RETURN PIPING
SAN SANITARY PIPING
V SANITARY VENT PIPING
PIPE UP
PIPE DOWN
GCO GRADE CLEAN OUT (1-WAY OR 2-WAY)OR
HOSE BIB WITH VACUUM BREAKER
OR VTR VENT THRU ROOF
WCO WALL CLEAN OUT
FCO FLOOR CLEAN OUT (1-WAY OR 2-WAY)OR
PIPE CAP
WCO
FLOOR DRAIN
BALL VALVE
FLOOR SINK
PLUMBING LEGEND
FD-C
FD-S
X-XX
CR COLD WATER RETURN PIPING
BACKFLOW PREVENTER
FIXTURE SCHEDULE
FIXTURE MARK FIXTURE DESCRIPTION
P-103
WATER CLOSET - WALL HUNG - ADA. AUTO FLUSH VALVE,
HARD WIRED, PROVIDE WITH TRANSFORMER. REFER TO
SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-114
WATER CLOSET - WALL HUNG - ADA REFER TO
SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-418
LAVATORY - WALL HUNG - ADA, AUTO FAUCET, HARD
WIRED, PROVIDE WITH TRANSFORMER. PROVIDE WITH
ASSE-1070 THERMOSTATIC MIXING VALVE. REFER TO
SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-502
JANITOR SINK. REFER TO SPECIFICATION SECTION 22 40 00
FOR MORE INFORMATION.
P-505
CLINICAL SINK, FLOOR MOUNTED, WITH SERVICE FAUCET
REFER TO SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-528
SINGLE COMPARTMENT SINK - COUNTER. REFER TO
SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-604
WATER COOLER. REFER TO SPECIFICATION SECTION 22 40
00 FOR MORE INFORMATION.
P-701
SHOWER STALL - ADA. REFER TO SPECIFICATION SECTION
22 40 00 FOR MORE INFORMATION.
P-708
EMERGENCY EYE/FACE WASH - WALL MOUNTED, PROVIDE
WITH ASSE-1071 THERMOSTATIC MIXING VALVE. REFER TO
SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-808
WASHING MACHINE OUTLET BOX. REFER TO
SPECIFICATION SECTION 22 40 00 FOR MORE
INFORMATION.
P-812
ICE MAKER OUTLET BOX. REFER TO SPECIFICATION
4 4
A
A
B
B
C
C
D
D E
E
0.50.5
A.5
STAIR 2
S2-2
LOGISTICS SUPPLY
A-210
UNIT 7
A-209
UNIT 8
A-207
UNIT 9
A-206
UNIT 10
A-204
UNIT 11
A-203 BARIATRIC UNIT 12
A-202
BARIATRIC BATH
A-202A
SHARED BATH
A-205
SHARED BATH
A-208
PRIVATE BATH
A-211
MED ROOM
A-227
NURSE STATION
A-226
STAFF TLT
A-225 HAC
A-224
ELEVATOR
A-002
CORRIDOR
A-250
LINEN & SUPPLY STOR.
A-201
UNIT 1
A-222
SECURE CORRIDOR
A-220
UNIT 2
A-221
SOILED UTILITY
A-419
SHARED BATH
A-223
TELECOM ROOM
A-219
STAIR 1
S2-1
UNIT 6
A-212
UNIT 5
A-213
UNIT 4
A-215
UNIT 3
A-216
SHARED BATH
A-217
SHARED BATH
A-214
2" OSD
2" OSD
2" OSD
2" SD
UTILITY ACCESS
A-421
2 1
2" SD
2" OSD
3" SD
2" SD
3" OSD
2" OSD
2" SD
2" SD
CO
CO
CO
2" SD
N
AREA B
KEY PLAN
WORK AREA
EXISTING BUILDING
EXISTING BUILDING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
TRIPLE C - The A/E Group 100 Pearl Street, 14th floor Hartfort, CT 06103
(315) 484-5958 Mat Perkins
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP
MES GROUP
550 North Reo St, Suite 203 Tampa, FL 33609
(813) 289-4700 Nicholas Stephensen, P.E.
STRUCTURAL
C&S Companies 2575 E Camelback Rd, Suite 740 Phoenix, AZ 85016
(602) 997-7536 Bryan K. Salt, P.E. S.E.
B
IM
/4
-3
C o n s tr u c t S u b s ta n c e U s e
R e s id e n ti a l R e h a b
B u ild in g /4
-3
.A u g u s ta
.M E
P F
.R
.r v t
/2
/2
:4
:2
P
M
PL102.1
PLUMBING PLAN - SECOND FLOOR STORM
DRAINAGE
402-318
BLDG 258
07/26/2022 DCM/CB TH/DCM
100% CONSTRUCTION
DOCUMENTS ISSUED FOR
BIDDING
Construct Substance Use Residential Rehab Building
1 VA Center, Augusta, Maine
1/4" = 1'-0"
LEVEL 2 PLUMBING PLAN - STORM DRAINAGE
PLUMBING SHEET NOTES
A THIS PLAN IS DIAGRAMMATIC IN NATURE AND SHALL NOT BE SCALED TO
DETERMINE THE LOCATION OR DIMENSION OF THE WORK. CONTRACTOR SHALL
VERIFY EXACT LOCATION OF PIPING AND PENETRATIONS.
B CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THE LOCATION OF EXISTING
BELOW GRADE WASTE PIPING AND REFLECT ANY DEVIATION GREATER THAN 1'-0"
FROM THIS PLAN ON THE AS-BUILT DRAWINGS.
C CUTTING, BORING, SAWCUTTING OR DRILLING THROUGH THE NEW AND EXISTING
STRUCTURAL ELEMENTS TO BE DONE ONLY WHEN DETAILED IN THE DRAWINGS
OR ACCEPTED BY THE APPROVAL THE STRUCTURAL ENGINEER AND VA.
D REPAIR WALL SURFACE AFTER INSTALLATION AND INSPECTION OF EACH
PLUMBING FIXTURE AND PIPING INSTALLED.
E ALL WALL-MOUNTED ACCESS PANELS SHALL BE LOCKABLE TYPE.
F MAINTAIN MINIMUM 10-0" SEPARATION BETWEEN FLUE AND PLUMBING VENT
OUTLETS AND ANY FRESH AIR INTAKE. COORDINATE WITH HVAC CONTRACTOR.
G FLOORS SHALL SLOPE TO DRAINS AT 1% MINIMUM SLOPE. SEE ARCHITECTURAL
PLANS FOR MORE INFORMATION.
H PROVIDE ALL FLOOR DRAINS, FLOOR SINKS, TRENCH DRAINS, ETC. WITH TRAP
GUARD DEVICES (ASSE 1072 COMPLIANT).
I PROVIDE WALL CLEAN OUTS IN ALL VENT RISERS ON BRANCHES LONGER THAN
5'-0" AND ON BRANCHES SERVING SINKS OR URINALS.
J SEE RISER DIAGRAMS FOR PIPE SIZING.
KEYNOTES
1 PRIMARY AND OVERFLOW STORM DRAINAGE TO OD AND RD ABOVE.
2 ROUTE RAIN LEADERS IN CEILING SPACE. COORDINATE INSTALLATION WITH
OTHER TRADES.
3 PRIMARY STORM DRAINAGE DOWN TO FLOOR BELOW. SEE PL101 FOR
CONTINUATION.
4 OVERFLOW STORM DRAINAGE DOWN TO FLOOR BELOW. SEE PL101 FOR
CONTINUATION.
Revisions: Date:
DRAWING KEYNOTE#
EQUIPMENT MARK
CW COLD WATER PIPING
HW HOT WATER PIPING
HWR HOT WATER RETURN PIPING
SAN SANITARY PIPING
V SANITARY VENT PIPING
PIPE UP
PIPE DOWN
GCO GRADE CLEAN OUT (1-WAY OR 2-WAY)OR
HOSE BIB WITH VACUUM BREAKER
OR VTR VENT THRU ROOF
WCO WALL CLEAN OUT
FCO FLOOR CLEAN OUT (1-WAY OR 2-WAY)OR
PIPE CAP
WCO
FLOOR DRAIN
BALL VALVE
FLOOR SINK
PLUMBING LEGEND
FD-C
FD-S
X-XX
CR COLD WATER RETURN PIPING
BACKFLOW PREVENTER
3" CW DOWN TO FLOOR BELOW
3" CW
4 4
A
A
B
B
C
C
D
D E
E
0.50.5
A.5
STAIR
2S-3
ELEC ROOM
A-301
EMERGENCY POWER
A-302
RD-1
362 SF
OD-1
362 SF OD-1
365 SF
RD-1
365 SF
RD-1
575 SF
OD-1
575 SF
RD-1
570 SF
OD-1
570 SF
OD-1
466 SF
RD-1
466 SF
OD-1
422 SF
RD-1
422 SF
OD-1
510 SF
RD-1
510 SF
3/4" HW-R
3" CW
3" HW
3/4" CR
4" SD
2" SD
2" SD
3" SD
2" SD
2" SD
3 2
2" OSD
3" OSD 3" OSD
2" OSD
2" OSD
1-3-HX01
1-3-HX02
3" VTR
3" VTR
3" VTR
1-3-TMV01
1-3-CPH01
1-3-CPC01
3" FD-1
3" FD-1
1-3-ROF01
1" RO
1" RO
2" FD-C
10 10 10 10
MECHANICAL PENTHOUSE
A-300
2" VTR
1/4" = 1'-0"
ROOF PLUMBING PLAN
PLUMBING SHEET NOTES
A THIS PLAN IS DIAGRAMMATIC IN NATURE AND SHALL NOT BE SCALED TO
DETERMINE THE LOCATION OR DIMENSION OF THE WORK. CONTRACTOR SHALL
VERIFY EXACT LOCATION OF PIPING AND PENETRATIONS.
B CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THE LOCATION OF EXISTING
BELOW GRADE WASTE PIPING AND REFLECT ANY DEVIATION GREATER THAN 1'-0"
FROM THIS PLAN ON THE AS-BUILT DRAWINGS.
C CUTTING, BORING, SAWCUTTING OR DRILLING THROUGH THE NEW AND EXISTING
STRUCTURAL ELEMENTS TO BE DONE ONLY WHEN DETAILED IN THE DRAWINGS
OR ACCEPTED BY THE APPROVAL THE STRUCTURAL ENGINEER AND VA.
D REPAIR WALL SURFACE AFTER INSTALLATION AND INSPECTION OF EACH
PLUMBING FIXTURE AND PIPING INSTALLED.
E ALL WALL-MOUNTED ACCESS PANELS SHALL BE LOCKABLE TYPE.
F MAINTAIN MINIMUM 10-0" SEPARATION BETWEEN FLUE AND PLUMBING VENT
OUTLETS AND ANY FRESH AIR INTAKE. COORDINATE WITH HVAC CONTRACTOR.
G FLOORS SHALL SLOPE TO DRAINS AT 1% MINIMUM SLOPE. SEE ARCHITECTURAL
PLANS FOR MORE INFORMATION.
H PROVIDE ALL FLOOR DRAINS, FLOOR SINKS, TRENCH DRAINS, ETC. WITH TRAP
GUARD DEVICES (ASSE 1072 COMPLIANT).
I PROVIDE WALL CLEAN OUTS IN ALL VENT RISERS ON BRANCHES LONGER THAN
5'-0" AND ON BRANCHES SERVING SINKS OR URINALS.
J SEE RISER DIAGRAMS FOR PIPE SIZING.
N
AREA B
KEY PLAN
WORK AREA
EXISTING BUILDING
EXISTING BUILDING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
TRIPLE C - The A/E Group 100 Pearl Street, 14th floor Hartfort, CT 06103
(315) 484-5958 Mat Perkins
STAMPCONSULTANT
321 4 5 6 7 8 9 10
MEP
MES GROUP
550 North Reo St, Suite 203 Tampa, FL 33609
(813) 289-4700 Nicholas Stephensen, P.E.
STRUCTURAL
C&S Companies 2575 E Camelback Rd, Suite 740 Phoenix, AZ 85016
(602) 997-7536 Bryan K. Salt, P.E. S.E.
B
IM
/4
-3
C o n s tr u c t S u b s ta n c e U s e
R e s id e n ti a l R e h a b
B u ild in g /4
-3
.A u g u s ta
.M E
P F
.R
.r v t
/2
/2
:4
:3
P
M
PL103
PLUMBING PLAN - PENTHOUSE 402-318
BLDG 258
07/26/2022 DCM/CB TH/DCM
100% CONSTRUCTION
DOCUMENTS ISSUED FOR
BIDDING
Construct Substance Use Residential Rehab Building
1 VA Center, Augusta, Maine
KEYNOTES
1 PROVIDE PRIMARY AND SECONDARY ROOF DRAINS SIZED PER CODE,
COORDINATE EXACT LOCATIONS WITH ARCHITECTURAL.
2 PRIMARY AND OVERFLOW STORM DRAINAGE TO OD AND RD ABOVE.
3 ROUTE RAIN LEADERS IN CEILING SPACE. COORDINATE INSTALLATION WITH
OTHER TRADES.
4 OVERFLOW STORM DRAINAGE DOWN TO FIRST FLOOR. SEE PL101 FOR
CONTINUATION.
5 PRIMARY STORM DRAINAGE DOWN TO FIRST FLOOR. SEE PL101 FOR
CONTINUATION.
6 PROVIDE 1" RO TREATED WATER DOWN TO CLEAN STEAM GENERATOR, 1-3-CSG01.
REFER TO MECHANICAL PLANS FOR CLEAN STEAM GENERATOR INFORMATION.
7 PROVIDE RO TREATED WATER FOR HYDRONIC MAKE-UP FEED WATER SUPPLY.
8 MECHANICAL CONDENSATE PIPING. RUN PIPING ALONG ADJACENT WALL AND
TERMINATE AT FLOOR DRAIN.
9 ROUTE MECHANICAL CONDENSATE PIPING FROM AIR HANDLER TO FLOOR DRAIN.
10 MECHANICAL EQUIPMENT SHOWN FOR REFERENCE. SEE MECHANICAL SHEETS
FOR MORE INFORMATION.
11 REFER TO SHEET PL102 FOR SANITARY PIPING SERVING FLOOR DRAIN.
Revisions: Date:
DRAWING KEYNOTE#
EQUIPMENT MARK
CW COLD WATER PIPING
HW HOT WATER PIPING
HWR HOT WATER RETURN PIPING
SAN SANITARY PIPING
V SANITARY VENT PIPING
PIPE UP
PIPE DOWN
GCO GRADE CLEAN OUT (1-WAY OR 2-WAY)OR
HOSE BIB WITH VACUUM BREAKER
OR VTR VENT THRU ROOF
WCO WALL CLEAN OUT
FCO FLOOR CLEAN OUT (1-WAY OR 2-WAY)OR
PIPE CAP
WCO
FLOOR DRAIN
BALL VALVE
FLOOR SINK
PLUMBING LEGEND
FD-C
FD-S
X-XX
CR COLD WATER RETURN PIPING
SECOND FLOOR SECTION 1
SECOND FLOOR SECTION 2
SECOND FLOOR SECTION 3
SECOND FLOOR SECTION 4
SECOND FLOOR SECTION 5
SECOND FLOOR SECTION 6 SECOND FLOOR SECTION 7
STORMWATER CALCULATIONS
DRAIN FLOW (GPM) =
RAINFALL RATE (in/hr) * ROOF AREA(ft2) * 144 (in2/ft2)
231 (in3/gal) * 60 (min/hr)
FLOOR ROOF CALCULATION - SECTION 1
ROOF AREA: 510 + 60 = 570 ft2
1/2 WALL AREA: 1/2 * 32 * 13 = 208 ft2
TOTAL AREA: 778 ft2
RAINFALL RATE: 2.3 in/hr (PER IPC-2021)
DRAIN FLOW: 18.6 GPM
PIPE SIZE: 2 in PIPE SLOPE: 1/8 in/ft (PER IPC-2021, TABLE 1106.2)
SECOND FLOOR ROOF CALCULATION - SECTION 2
ROOF AREA: 422 ft2
RAINFALL RATE: 2.3 in/hr (PER IPC-2021)
DRAIN FLOW: 10.1 GPM
PIPE SIZE: 2 in PIPE SLOPE: 1/8 in/ft (PER IPC-2021, TABLE 1106.2)
SECOND FLOOR ROOF CALCULATION - SECTION 3
ROOF AREA: 466+60 = 526 ft2
RAINFALL RATE: 2.3 in/hr (PER IPC-2021)
DRAIN FLOW: 12.6 GPM
PIPE SIZE: 2 in PIPE SLOPE: 1/8 in/ft (PER IPC-2021, TABLE 1106.2)
SECOND FLOOR ROOF CALCULATION - SECTION 4
ROOF AREA: 362 ft2
1/2 WALL AREA: 1/2 * 24 * 13 = 156 ft2
TOTAL AREA: 518 ft2
RAINFALL RATE: 2.3 in/hr (PER IPC-2021)
DRAIN FLOW: 12.4 GPM
PIPE SIZE: 2 in PIPE SLOPE: 1/8 in/ft (PER IPC-2021, TABLE 1106.2)
SECOND FLOOR ROOF CALCULATION - SECTION 5
ROOF AREA: 365 ft2
1/2 WALL AREA: 1/2 * 24.25 * 13 = 158 ft2
TOTAL AREA: 523 ft2
RAINFALL RATE: 2.3 in/hr (PER IPC-2021)
DRAIN FLOW: 12.5 GPM
PIPE SIZE: 2 in PIPE SLOPE: 1/8 in/ft (PER IPC-2021, TABLE 1106.2)
SECOND FLOOR ROOF CALCULATION - SECTION 6
ROOF AREA: 575 + 60 = 635 ft2
1/2 WALL…
This is the start of the file's text. The full file is on GovTribe.