36C26324Q1120 0005.pdf
PDF 140 KB Posted
- Attached to
- 5340--Replace Fire Rated Doors - MPLS Federal contract opportunity
- Solicitation number
- 36C26324Q1120
About this file
This document is a solicitation amendment for Request for Quotes (RFQ) number 36C26324Q1120 to replace fire-rated doors at the Minneapolis VA Health Care System. The Statement of Work outlines the requirement to replace 29 fire-rated doors and 3 non-rated doors, including details on door specifications, installation requirements, and contractor responsibilities. The solicitation is a total Service-Disabled Veteran-Owned Small Business (SD/VOSB) set-aside with a North American Industry Classification System (NAICS) code of 332321. Quotes are due by 1:00 PM on 9/27/2024 and must be emailed to the Contracting Officer. The period of performance is 12/1/2024 to 5/30/2025 for the base year. The solicitation is issued by the Department of Veterans Affairs, Veterans Integrated Service Network 23.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C26324Q1120 0004.pdf | ||
| 36C26324Q1120 0003.pdf | ||
| 36C26324Q1120 02.pdf | ||
| 36C26324Q1120 0001.pdf | ||
| 36C26324Q1120_2.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5. PROJECT NUMBER (if applicable)
CODE7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO. 1. CONTRACT ID CODE
FACILITY CODECODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER 16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30 PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243
(Type or print) (Type or print)
(Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code)
(If other than Item 6)
(Specify type of modification and authority)
(such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer)
1 5
0005 36C263-24-AP-4464
618-25-1-6017-0001
36C618
Department of Veterans Affairs Minneapolis VAMC
One Veterans Drive Minneapols MN 55417 Robert Bennett robert.bennett8@va.gov
36C263
Department of Veterans Affairs
NETWORK 23 CONTRACTING OFFICE
1303 5th St, Suite 300 Coralville IA 52241
To all Offerors/Bidders
36C26324Q1120
10-16-2024
X
X X
X 1
The purpose of this amendment is to update the Statement of Work (SOW).
1.) Please see the updated SOW. Updates are highlighted in yellow.
2.) The due date for quotes has not changed and is 10/21/24 at 1:00 PM
Traci Johannes Contracting Officer
STATEMENT OF WORK
Minneapolis Veteran Affairs Health Care System “Replace Fire Rated Doors”
1. Introduction:
a. There are 29 fire rated doors and 3 non-rated doors that need to be replaced throughout the Minneapolis Minnesota Veteran Affairs Medical Center. These are a combination of wood and hollow metal doors. Each door must meet the fire rating for that room or area that is identified in the table below.
b. One on site assessment is authorized to evaluate the work to be performed and provide the most accurate price quote. Assessment must be completed prior to the closing date of the solicitation.
c. Contract will be awarded as a “firm-fixed” price contract.
2. Objectives:
a. Safely perform all items outlined in the Statement of Work. Perform all work with minimum impact to patient care.
3. Statement of Work:
a. Replace the following fire doors:
Location Qty Lite Kit
Door Material
Fire Rating
Lockset function Kick Plate
Door Closer
Hinges (Qty)
BC103 1 HM 45 L9010 18" 1 5HD
BC104 1 Y HM 90 L9010 18" 1 5HD
BD101 2 HM 45 Reuse 18” REUSE REUSE
BV104 2 WD 20 L9050 (2)34X36 R REUSE 4.5
C196A 2 Y WD 90 (2)9927 VR 18” 2 5HD
C196B 2 Y WD 90 (2)9927 VR 18" 2 5HD
1A103 1 Y WD 90 L9010 18" 1 5HD
1G106 2 Y WD 90 (2)9927 VR 18" 2 4.5
1C121 1 Y WD 90 L9080 18" 1 4.5HD
SC164 1 Y WD 45 REUSE BEST - 18” REUSE REUSE
SC163 2 Y WD 45 REUSE BEST - 18" REUSE REUSE
2A101 1 Y WD 90 L9080 NOTCHED 44" REUSE 5HD
C2112 2 Y WD 90 (2)9927 VR NOTCHED 44" 2 5HD
3A103 1 Y WD 90 L9010 NOTCHED 44" 1 5HD
3A102 1 Y WD 90 L9010 18" 1 5HD
3A101 1 Y HM 90 L9080 18" 1 5HD
C3117 2 Y WD 90 (2)9927 VR 18" 2 5HD
3V139 1 Y WD 90 REUSE L9010 18" REUSE 4.5
1J121 2 HM 45 L9080 18" 1 4.5
4P100 1 Y WD 90 L9092EU 18" 1 5HD
4Q100 1 Y WD 90 L9092EU 18" 1 5HD
Bldg 69-
DR107 1 Y
HM
Replace Door & Frame NR
Rim Exit device -
99EO4FT26D,
Trim - 990NL 8” 1 5HD
WD – Prefinished Red Oak HM - Hollow Metal
a. Contractor will need to perform their own measuring of each opening to determine correct door size and determine handing of each door. VA staff will not perform measuring for the contractor. The VA will not incur additional expenses for miscalculating materials and/or labor.
b. Corridor doors (C196A, C196B, 1G106, C2112 and C3117) Vertical rods will be upper rods only. Overlapping edge astragal will be replaced with a split or meeting edge astragal that are adjustable. Doors will need to operate independently from each other.
c. Bldg 69 door # 107 is the only location that will need both the door and frame replaced.
d. Contractor shall supply all tools, labor, and materials to replace all doors listed in table above.
e. See table for additional items identified to be added for each door: lite kit, lockset, kick plate, door closer, etc. Reuse lock sets and door closers were indicated in table.
f. Work that will create excessive noise or vibration will need to be conducted after normal business hours. Normal hours identified as 7:00 am – 5:00pm
g. All newly installed doors will swing without binding or rubbing. Locks will latch properly in the strike plate. Door surface will be flush with door frame without excessive gaps.
h. Locks will function properly. Rim cylinders will accept 7 pin cores and meet Small Format Interchangeable Core (SFIC) specifications.
i. MVAHCS will provide and install SFIC Cores after doors and locks have been installed.
j. The color and sheen of door finishes will match the finish of the door being replaced.
k. Each door must display the proper fire rating identification plate on the hinge side of each door.
l. Door closers will close and latch each door unassisted with in the time limits set forth in NFPA 80. Reuse door closers where indicated.
m. Old doors and materials can be disposed in dumpsters provided by the Minneapolis VA. Metal items will be placed in “scrap metal” dumpster and wood materials will be placed in “scrap wood” dumpster.
n. Work needs to be completed within 180 days of “Notice to Proceed”.
4. Working hours:
a. Anticipated hours of work will be Monday through Friday from 7:00 am – 5:00
pm. Additional hours must be coordinated through the COR. Work will not be performed on weekends or federal holidays.
Observed Federal Holidays:
New Year’s Day Martin Luther King Birthday Washington’s Birthday Memorial Day Juneteenth Independence Day Labor Day Columbus Day Veteran’s Day Thanksgiving Day Christmas Day
5. References:
NFPA 80
6. Safety:
a. Contractor is responsible for maintaining a safe working environment for their employees as well as the MVAHACS Staff. Work areas will be kept cleaned throughout the day and all trash and demolished materials properly disposed of daily.
b. Appropriate Personnel Protective Equipment will be worn while performing work on the VA Campus.
7. Security:
a. Contract personnel need to obtain a vendor’s badge form VA Security located at the outpatient entrance security desk. A valid government issued form of identification will be required to receive a badge. A charge of $25 will be assessed for any badges that are not returned at the completion of the project
b. Contractor’s Technicians are required to check in with the COR upon arrival at facility to obtain access and any additional instructions, task explanations and project location information. Daily performance log sheets are required to be submitted to the CO and COR daily.
8. Parking/Storage:
a. Parking is available in parking lots 11, 43A and 43B for vehicles (automobiles and Pickup trucks). Larger vehicles, equipment, job site trailers or storage containers must utilize parking lot 43A only. Contractor’s contact information (name and phone number) is required to be displayed on all vehicles, equipment, trailers or containers that are stored overnight at the MVAHCS.
Dropping off tools and materials at the loading dock is permitted but no parking is allowed in the loading dock area. Unattended vehicles in unauthorized parking areas will be ticketed by MVAHCS Police.
END