Low Voltage IDIQ Price Schedule Sheet_updated 5.15.20 (1 page).xlsx
XLSX spreadsheet 18 KB Posted
- Attached to
- Z1DA--Project: Low Voltage - Indefinite Delivery Indefinite Quantity (IDIQ) Contract Lowest Price Technically Acceptable Federal contract opportunity
- Solicitation number
- 36C26320R0102
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C26320R0102 0002.docx | DOCX document | |
| Low Voltage IDIQ Price Schedule Sheet_updated 5.29.20 (1 page).xlsx | XLSX spreadsheet | |
| Redacted Justification for Single Source_Panduit (2 pages).pdf | ||
| Low Voltage IDIQ Solicitation Questions and Responses (2 pages).pdf | ||
| 36C26320R0102 0001.docx | DOCX document | |
| Low Voltage IDIQ Site Visit Sign-In and Agenda 5.11.20 (2 pages).pdf | ||
| 36C26320R0102-011.pdf | ||
| 36C26320R0102-008.pdf | ||
| 36C26320R0102-012.pdf | ||
| 36C26320R0102-007.docx | DOCX document | |
| 36C26320R0102-009.xlsx | XLSX spreadsheet | |
| 36C26320R0102-010.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Price Schedule
| Low Voltage IDIQ | |||||||||||||||||||
| Price Schedule Sheet | 1.5 | ||||||||||||||||||
| updated: May 15, 2020 | 103% | 103% | 103% | ||||||||||||||||
| Low Voltage Services | Ordering Period 1: July 1, 2020 - June 30, 2021 | Ordering Period 2: July 1, 2021 - June 30, 2022 | Ordering Period 3: July 1, 2022 - June 30, 2023 | Ordering Period 4: July 1, 2023 - June 30, 2024 | Ordering Period 5: July 1, 2024 - June 30, 2025 | ||||||||||||||
| CLIN | Item Description | Unit of Measure | Est Qty | Price | Extended Amount | Est Qty | Price | Extended Amount | Est Qty | Price | Extended Amount | Est Qty | Price | Extended Amount | Est Qty | Price | Extended Amount | Minimum | Maximum |
| 0001 | Mobilization fee | Per task Order | 4 | 4 | 4 | 4 | 4 | 1 | 30 | ||||||||||
| 0002 | Cat 6 Plenium Cable single run per LNFT in cable tray w/labeling | LNFT | 2000 | 2000 | 2000 | 2000 | 2000 | 100 | 15000 | ||||||||||
| 0003 | Cat 6 Plenium Cable additional run per LNFT in cable tray w/ labeling | LNFT | 8000 | 8000 | 8000 | 8000 | 8000 | 0 | 60000 | ||||||||||
| 0004 | Cat 6 Plenium cable installed in conduit | LNFT | 1000 | 1000 | 1000 | 1000 | 1000 | 0 | 7500 | ||||||||||
| 0005 | Cat 6 Plenium cable Free Air Cable run | LNFT | 400 | 400 | 400 | 400 | 400 | 0 | 3000 | ||||||||||
| 0006 | Cat 6 Plenium installed in existing conduit | LNFT | 200 | 200 | 200 | 200 | 200 | 0 | 1500 | ||||||||||
| 0007 | Panduit Cat 6 RJ45 jack (Male) | Each | 150 | 150 | 150 | 150 | 150 | 0 | 1125 | ||||||||||
| 0008 | Panduit Cat 6 modular connector (Female) | Each | 150 | 150 | 150 | 150 | 150 | 0 | 1125 | ||||||||||
| 0009 | Cat 6A Plenium Cable single run per LNFT in cable tray w/labeling | LNFT | 500 | 500 | 500 | 500 | 500 | 0 | 3750 | ||||||||||
| 0010 | Cat 6A Plenium Cable additional run per LNFT in cable tray w/labeling | LNFT | 500 | 500 | 500 | 500 | 500 | 0 | 3750 | ||||||||||
| 0011 | Cat 6A Plenium installed in existing conduit | LNFT | 100 | 100 | 100 | 100 | 100 | 0 | 750 | ||||||||||
| 0012 | Panduit Cat 6A RJ45 jack (Male) | Each | 50 | 50 | 50 | 50 | 50 | 0 | 375 | ||||||||||
| 0013 | Panduit Cat 6A modular connector (Female) | Each | 50 | 50 | 50 | 50 | 50 | 0 | 375 | ||||||||||
| 0014 | Install conduit (EMT) assembly 3/4" diameter (includes condiut and all fittings) | LNFT | 100 | 100 | 100 | 100 | 100 | 0 | 750 | ||||||||||
| 0015 | Install conduit (EMT) assembly 1" diameter (includes conduit and all fittings) | LNFT | 100 | 100 | 100 | 100 | 100 | 0 | 750 | ||||||||||
| 0016 | Install conduit(EMT) assembly 2" diameter (includes conduit and all fittings) | LNFT | 40 | 40 | 40 | 40 | 40 | 0 | 300 | ||||||||||
| 0017 | Panduit Face Plate single gang Plastic 1-6 ports | Each | 120 | 120 | 120 | 120 | 120 | 0 | 900 | ||||||||||
| 0018 | Panduit Face Plate double gang Plastic 7-12 ports | Each | 20 | 20 | 20 | 20 | 20 | 0 | 150 | ||||||||||
| 0019 | Deep Metal Single gang box install | Each | 50 | 50 | 50 | 50 | 50 | 0 | 375 | ||||||||||
| 0020 | Deep Metal double gang box install | Each | 50 | 50 | 50 | 50 | 50 | 0 | 375 | ||||||||||
| 0021 | wire mold install | LNFT | 100 | 100 | 100 | 100 | 100 | 0 | 750 | ||||||||||
| 0022 | velcro wraps 1"W X 12" Lg | Each | 300 | 300 | 300 | 300 | 300 | 0 | 2250 | ||||||||||
| 0023 | 2 inch "J" hooks hanger support & Associated hardware (1 hook per 4 LNFT) | Each | 50 | 50 | 50 | 50 | 50 | 0 | 375 | ||||||||||
| 0024 | 4 inch "J" hooks hanger support & Associated hardware (1 hook per 4 LNFT) | Each | 50 | 50 | 50 | 50 | 50 | 0 | 375 | ||||||||||
| 0025 | Fire Wall or Ceiling Penetration and fire caulk (2 hour) | Each | 75 | 75 | 75 | 75 | 75 | 0 | 562.5 | ||||||||||
| 0026 | 3" dia Concrete core drilling w/fire sleeve and bushings per inch | Each | 10 | 10 | 10 | 10 | 10 | 0 | 75 | ||||||||||
| 0027 | Protective barriers w/one zipper Up to 10 feet tall | LNFT | 200 | 200 | 200 | 200 | 200 | 0 | 1500 | ||||||||||
| 0028 | Portable Cube enclosure | Daily | 15 | 15 | 15 | 15 | 15 | 0 | 112.5 | ||||||||||
| 0029 | Hepa filter machine Less than 1500 CFM | Daily | 15 | 15 | 15 | 15 | 15 | 0 | 112.5 | ||||||||||
| 0030 | Hepa filter machine Greater than 1500 CFM | Daily | 2 | 2 | 2 | 2 | 2 | 0 | 15 | ||||||||||
| 0031 | Set up Scaffolding (Labor only) | Daily | 2 | 2 | 2 | 2 | 2 | 0 | 15 | ||||||||||
| 0032 | Personnel Lift | Daily | 4 | 4 | 4 | 4 | 4 | 0 | 30 | ||||||||||
| 0033 | Panduit Patch Cables | LNFT | 50 | 50 | 50 | 50 | 50 | 0 | 375 | ||||||||||
| 0034 | Panduit Patch Panels 24 port angled Unpopulated | Each | 2 | 2 | 2 | 2 | 2 | 0 | 15 | ||||||||||
| 0035 | Panduit Patch Panel 48 port angled Unpopulated | Each | 2 | 2 | 2 | 2 | 2 | 0 | 15 | ||||||||||
| 0036 | Panduit Patch Panel 24 port flat Unpopulated | Each | 2 | 2 | 2 | 2 | 2 | 0 | 15 | ||||||||||
| 0037 | Panduit Patch Panel 24 port flat Unpopulated | Each | 2 | 2 | 2 | 2 | 2 | 0 | 15 | ||||||||||
| 0038 | Panduit Patch Panel 24 port voice Populated | Each | 2 | 2 | 2 | 2 | 2 | 0 | 15 | ||||||||||
| 0039 | Remove and relocate tip jack | Each | 2 | 2 | 2 | 2 | 2 | 0 | 15 | ||||||||||
| 0040 | Relocate Patch Panels/Rewire | Each | 2 | 2 | 2 | 2 | 2 | 0 | 15 | ||||||||||
| Total | Total | Total | Total | Total | Grand Total |
| Ordering procedures: Orders will be generated by the NCO23 Contracting Office. |
| Each order will document the quantity of services that are required. No additional |
| services are authorized without prior approval of the administrative Contracting |
| Specialist or Contracting Officer. |
File details come from the government source that posted it. Updated .