438-18-101_100PC_VEG_18.1_PDF_Combined_Sioux_Falls.pdf
PDF 22 MB Posted
- Solicitation number
- 36C26319Q0140
About this file
36C26319Q0140 0004 438-18-101 100PC VEG 18.1 PDF Combined Sioux Falls.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1_Line_Section_A_revised_Iowa_City.pdf | ||
| E6_Sioux_Falls.dwg | DWG drawing | |
| E7_Sioux_Falls.dwg | DWG drawing | |
| E2_Sioux_Falls.dwg | DWG drawing | |
| E3_Sioux_Falls.dwg | DWG drawing | |
| E9_Sioux_Falls.dwg | DWG drawing | |
| 1_Line_Section_B_revised_Iowa_City.pdf | ||
| 1_Line_Clinic_Addn_Iowa_City.pdf | ||
| E5_Sioux_Falls.dwg | DWG drawing | |
| E4_Sioux_Falls.dwg | DWG drawing | |
| 36C26319Q0140_0004.docx | DOCX document | |
| E10_Sioux_Falls.dwg | DWG drawing | |
| E8_Sioux_Falls.dwg | DWG drawing | |
| E1_Sioux_Falls.dwg | DWG drawing | |
| 1_Line_40-41_Generator_Iowa_City.pdf | ||
| 36C26319Q0140_0003.docx | DOCX document | |
| 36C26319Q0140_0002.docx | DOCX document | |
| 36C26319Q0140_0001.docx | DOCX document | |
| 36C26319Q0140_1.docx | DOCX document | |
| S02_36C26319Q0140.pdf | ||
| 100_percent_report_consolidated_SF.pdf |
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE PLAN BUILDING SHEET NUMBERS
ROYAL C. JOHNSON VA MEMORIAL MEDICAL CENTER PROJECT
#438-18-101, BID DOCUMENTS
AE ELECTRICAL DEFICIENCIES CAMPUS WIDE (SF)
T11
T12
T13
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
G-001
COVER SHEET AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
438-18-101
AS NOTED
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
SITE PLAN
NO SCALE
Plan North
CONSTRUCTION DOCUMENTS
AutoCAD SHX Text
GARFIELD AVENUE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PRKG. #5
AutoCAD SHX Text 26th STREET
AutoCAD SHX Text bruce is a weeny.
AutoCAD SHX Text
PARKING #4
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PARKING #2A
AutoCAD SHX Text
AutoCAD SHX Text
PARKING #2
AutoCAD SHX Text
PARKING #1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VETERANS
AutoCAD SHX Text
MEMORIAL
AutoCAD SHX Text
SIGN
AutoCAD SHX Text 22nd STREET
AutoCAD SHX Text
LINCOLN
AutoCAD SHX Text
ELMWOOD
AutoCAD SHX Text
HOLLY
AutoCAD SHX Text 24th ST.
AutoCAD SHX Text
LINCOLN
AutoCAD SHX Text
HOLLY
AutoCAD SHX Text
AutoCAD SHX Text
TUNNEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TEMPORARY
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING #8A
AutoCAD SHX Text
PARKING #8B
AutoCAD SHX Text
PARKING #6
AutoCAD SHX Text
PRKG. #7
AutoCAD SHX Text
PRKG. #3A
AutoCAD SHX Text
PRKG. #3B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text T11
AutoCAD SHX Text T13
AutoCAD SHX Text T12
AutoCAD SHX Text T15
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text rwwhe Image
" C
LR
2'-0"
'-0
14'-0"
'-4
S-101
CONCEPTUAL SECTION VIEW
FIXED BOLLARD
IN REINFORCED
CONCRETE FOOTING
DIRECTION OF
IMPACT
SECTION AT EQUIPMENT SLAB
SCALE 3/4" = 1'- 0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
S-101
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
438-18-101
B5
CE THVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
CONSTRUCTION DOCUMENTS
GENSET PAD PLAN
BUILDING 5 EQUIPMENT PADS
SCALE 1/4" = 1'- 0"
GENERAL STRUCTURAL NOTES:
1. THE DRAWINGS INDICATE THE SIZE AND RELATIVE LOCATION OF
STRUCTURAL MEMBERS, THE DESIGN LOADS, AND OTHER
INFORMATION PERTINENT TO THE STRUCTURAL DESIGN. THEY DO
NOT INDICATE THE METHODS OF CONSTRUCTION.
2. SIZE AND RELATIVE LOCATION OF EXISTING STRUCTURAL MEMBERS
ARE SHOWN FOR REFERENCE. THE CONTRACTOR SHALL FIELD VERIFY
BEFORE BEGINNING DEMOLITION OR NEW CONSTRUCTION.
3. SEE THE SPECIFICATIONS FOR INFORMATION NOT SHOWN IN THE
DRAWINGS. IF A DISCREPANCY IS FOUND, THE DRAWINGS WILL TAKE
PRECEDENCE OVER THE SPECIFICATIONS.
1. PROVIDE STEEL REINFORCEMENT AND CONNECTORS AS FOLLOWS:
REINFORCING BARS ASTM A615 (60 KSI)
WELDABLE REINFORCING BARS ASTM A706 (60 KSI)
ANCHOR RODS ASTM F1554 (36 KSI)
THREADED RODS ASTM A36 (36 KSI)
2. SEE SPECIFICATIONS FOR BALANCE OF INFORMATION NOT SHOWN.
3. PROVIDE MINIMUM 28 DAY STRENGTH (f'c) AS FOLLOWS:
FOOTINGS AND FOUNDATIONS 3,000 PSI (AIR ENTRAINED)
EQUIPMENT PADS 3,000 PSI (AIR ENTRAINED)
ALL OTHER CONCRETE 4,000 PSI (AIR ENTRAINED)
CONCRETE NOTES:
1. BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE (IBC).
2. WIND DESIGN DATA: (ASCE 7-10)
ULTIMATE DESIGN WIND SPEED, VULT 120 MPH
RISK CATEGORY IV
WIND EXPOSURE B
INTERNAL PRESSURE COEFFICIENT N/A
COMPONENT, CLADDING PRESSURES N/A
3. EARTHQUAKE DESIGN DATA: (ASCE 7-10)
RISK CATEGORY IV
SEISMIC IMPORTANCE FACTOR, IE 1.5
SS 0.09
S1 0.035
SITE CLASS (ASSUMED) D
SEISMIC DESIGN CATEGORY D
SEISMIC FORCE RESTING SYSTEM N/A
DESIGN BASE SHEAR, V N/A
SEISMIC RESPONSE COEFFICIENTS, CS N/A
RESPONSE MODIFICATION FACTOR, R N/A
ANALYSIS PROCEDURE USED MECHANICAL
EQUIPMENT CHAP 13
4. GEOTECHNICAL INFORMATION:
ALLOWABLE SOIL BEARING PRESSURE 1500 PSF (ASSUMED)
ACTIVE LATERAL PRESSURE N/A
PASSIVE LATERAL PRESSURE N/A
COEFFICIENT OF FRICTION N/A
5. SPECIAL LOADS:
700 kW GENSET 80,600 LBS
DESIGN CRITERIA:
07/06/2018
EARTHWORK NOTES:
1. PROVIDE AGGREGATE BASE COURSE PER SDDOT SECTION 882.2
TABLE 1 (EXCEPTION #200 MINUS 3.0 - 7.0).
2. PROVIDE 24" AGGREGATE BASE EXTENDING 24" BEYOND
EXTERIOR EDGE OF CONCRETE PAD.
3. MATERIAL SHALL BE COMPACTED TO 97% OF MAXIMUM DRY
DENSITY.
4. THE MAXIMUM DRY DENSITY SHALL BE DETERMINED BY SD 104
METHOD 4.
5. THE PERCENT OF THE MAXIMUM DRY DENSITY WILL BE
DETERMINED BY 105, SD 110, OR SD 114.
15" THICK REINFORCED CONCRETE PAD
MECHANICAL EQUIPMENT PER PLAN
1" CHAMFER
BACKFILL
24" DEEP AGGREGATE BASE COURSE.
EXTEND 24" PAST EDGE OF CONCRETE PAD
#4 BARS AT 12" O.C., TOP & BOTTOM, EACH
WAY WITH 2" COVER TO OUTSIDE EDGE, U.N.O.
15" THICK CONCRETE
PAD FOR NEW GENSET
PROVIDE STUBOUTS PER GENSET
MANUFACTURER'S DETAILS
NATIVE SOIL
NOTES:
1. CONTRACTOR SHALL PROVIDE M30-P1 BOLLARD SYSTEMS, PER ASTM F2656-07.
2. INSTALLATION AND LOCATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
3. DO NOT SCALE DRAWING.
4. CONTRACTOR SHALL HAVE BOLLARDS DESIGNED BY MANUFACTURER TO MEET PROJECT REQUIREMENTS.
5. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED
AND APPROVED BY THE PRODUCT MANUFACTURER TO BE CONSIDERED ACCURATE.
BOLLARD DETAIL
SCALE 1/4" = 1'- 0"
M30-P1 BOLLARD
SYSTEM, TYPICAL.
SEE DETAIL 3/S-101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
E-001
ELECTRICAL ABBREVIATIONS &
SYMBOLS
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
ELECTRICAL ABBREVIATIONS
NEUT OR N
NC
NEUTRAL
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
NS NO SCALE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OL OVERLOAD
P POLE
PA PUBLIC ADDRESS
PB PULL BOX, PANEL BOARD, PUSH BUTTON
PBPU PREFABRICATED BEDSIDE PATIENT UNIT
PCB POLYCHLORINATED BIPHENYL
PEC PHOTOELECTRIC CELL
PED PEDESTAL
PEND PENDANT
PF POWER FACTOR
PH PHASE
PNL PANEL
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
RCP REFLECTED CEILING PLAN
REC RECESSED
RECPT RECEPTACLE
REQ REQUIRED
RGS RIGID GALVANIZED STEEL
RM ROOM
RMS ROOT MEAN SQUARE
SCC SHORT CIRCUIT CAPACITY
SES SERVICE ENTRANCE SECTION
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SHT SHEET
SI INTERNATIONAL SYSTEM OF UNITS
SPEC SPECIFICATION
SPST SINGLE POLE, SINGLE THROW
SURF SURFACE
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
TEL TELEPHONE
TP TWISTED PAIR
TPS TWISTED PAIR SHIELDED
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
TYP TYPICAL
UFD UNDERFLOOR DUCT
UGND UNDERGROUND
UL UNDERWRITERS LABORATOY
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UTIL UTILITY
V VOLT
VA VOLT·AMPERE
VAR VOLT AMPERE REACTIVE
VFD VARIABLE FREQUENCY DRIVE
VOLT VOLTAGE
W WATT
WH WATER HEATER
WP WEATHERPROOF
XFER TRANSFER
XFMR TRANSFORMER
ELECTRICAL ABBREVIATIONS
DRSW DOOR SWITCH
DS DISCONNECT SWITCH
DWG DRAWING
EL ELEVATION
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMCP EMERGENCY MONITORING CONTROL PANEL
EMER EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EPO EMERGENCY POWER OFF
EPRF EXPLOSION PROOF
ESMT EASEMENT
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EXST EXISTING
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FABL FIRE ALARM BELL
FABX FIRE ALARM BOX
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FIXT FIXTURE
FLA FULL LOAD AMPS
FLEX FLEXIBLE METALLIC CONDUIT
FLT FLOODLIGHT
FLUOR FLUORESCENT
FLUOR
FIX
FLUORESCENT FIXTURE
FOUTT TELEPHONE FLOOR OUTLET
FP FIRE PROTECTION
FT FEET OR FOOT
FU SW FUSED SWITCH
FVNR FULL VOLTAGE NON-REVERSING
FVR FULL VOLTAGE REVERSING
G OR GND ELECTRICAL GROUND
GEN GENERATOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GTB GROUND TERMINAL BOX
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HT HEIGHT
HZ HERTZ
IESNA ILLUMINATION ENGINEERING SOCIETY OF
NORTH AMERICA
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
IWH INSTANTANEOUS WATER HEATER
J-BOX JUNCTION BOX
KV KILOVOLT
KVA KILOVOLT AMPERE
KVAH KILOVOLT AMPERE PER HOUR
KVAR KILOVOLT AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
KWHM KILOWATT HOUR METER
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LM LUMEN
LP LIGHT POLE
LPS LOW PRESSURE SODIUM
LRA LOCKED ROTOR AMPS
LT LIGHT
LTG LIGHTING
LTG PNL LIGHTING PANEL
LTNG LIGHTNING
LV LOW VOLTAGE
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MC METAL-CLAD
MCA MINIMUM CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MG MOTOR GENERATOR
MH MANHOLE
MIN MINIMUM
MLO MAIN LUGS ONLY
MOCP MAXIMUM OVERCURRENT PROTECTION
MT MOUNT
MTD MOUNTED
MTG MOUNTING
MTS MANUAL TRANSFER SWITCH
MV MEDIUM VOLTAGE
MVA MEGAVOLT·AMPERE
MW MEGAWATT
NA NOT APPLICABLE
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS
ASSOCATION
ELECTRICAL ABBREVIATIONS
SINGLE POLE
1PH SINGLE PHASE
2/C TWO-CONDUCTOR
3/C THREE-CONDUCTOR
3PH THREE PHASE
4/C FOUR-CONDUCTOR
4W FOUR WIRE
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT / ENGINEER
AAP ALARM ANNUNCIATOR PANEL
AC ALTERNATING CURRENT OR ARMORED
CABLE
ACC ACCESSIBLE
ADDL ADDITIONAL
ADJ ADJACENT OR ADJOINING
ADO AUTOMATIC DOOR OPENER
AMPERE FRAME OR AMP FUSE
AFC ABOVE FINISHED COUNTER, AUTOMATIC
FREQUENCY CONTROL, OR AVAILABLE
FAULT CURRENT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AH AMPERE·HOUR
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERE INTERRUPTING CAPACITY
ALT ALTERNATE
AMB OR A AMBIENT
AMP AMPERE
ARCH ARCHITECT
ASC AMPS SHORT CIRCUIT
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
BAT BATTERY
BC BARE COPPER
BD BOARD
BFF BELOW FINISHED FLOOR
BIL BASIC INSULATION LEVEL
BLDG BUILDING
BPIP BOILER PLANT INSTRUMENTATION PANEL
BRKR BREAKER
BYP BYPASS
CONDUIT
CAB CABINET
CALC CALCULATE
CAP CAPACITY
CAT CATALOG
CATV COMMUNITY ANTENNA TELEVISION
CCR CONTROL CONTACTOR
CCTV CLOSED CIRCUIT TELEVISION
CD CANDELA OR CONSTRUCTION DOCUMENTS
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED / CONTRACTOR
INSTALLED
CF/OI CONTRACTOR FURNISHED / OWNER
INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CHW CHILLED WATER
CHWP CHILLED WATER PUMP
CKT CIRCUIT
CKT
BRKR
CIRCUIT BREAKER
CLF CURRENT LIMITING FUSE
CLG CEILING
CMU CONCRETE MASONRY UNIT
COAX COAX CABLE
COMM COMMUNICATION
COMPT COMPARTMENT
CONC CONCRETE
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CPT CONTROL POWER TRANSFORMER
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CTV CABLE TELEVISION
CU COPPER
CU FT CUBIC FEET
CUR CURRENT
DB DECIBEL
DC DIRECT CURRENT
DCP DIMMER CONTROL PANEL
DEG C DEGREES CELSIUS
DEG F DEGREES FAHRENHEIT
DEMO DEMOLITION
DIAG DIAGRAM
DISC DISCONNECT
DISTR DISTRIBUTION
DISTR
PNL
DISTRIBUTION PANEL
DMR SW DIMMER SWITCH
DN DOWN
DPDT DOUBLE POLE, DOUBLE THROW
DPST DOUBLE POLE, SINGLE THROW
G
R
TIME CLOCK
VENTILATOR OR FAN COIL UNIT OUTLET
CONDUIT TERMINATED 6" AFF IN STANDARD BOX FOR
EXTENSION TO EQUIPMENT AS DIRECTED.
CONDUIT TERMINATED W/COUPLING (FLUSH W/FINISHED
FLOOR) FOR EXTENSION TO EQUIPMENT AS DIRECTED.
JUNCTION BOX
TRANSFORMER, PLAN
MOTOR, SINGLE-PHASE
MOTOR, THREE-PHASE
WYE CONNECTION
DUCT, CELL FLOOR HEADER
DUCT, TROLLEY
DUCT, UNDERFLOOR
JUNCTION BOX
EARTH GROUND
LADDER CABLE TRAY
BRANCH CIRCUIT HOMERUN. LINES INDICATE NUMBER OF
CIRCUITS,NEUTRAL, AND SWITCH LEG CONDUCTORS. ONE
SEPARATE GREEN GROUNDING CONDUCTOR SHALL BE
PROVIDED FOR EACH HOMERUN;NOT SHOWN
WIREWAY
RIGID CONDUIT LINE = RC
SUBSTATION
BUSWAY
FLOOR OUTLET, DATA COMMUNICATION
OUTLET, DATA COMMUNICATION
PUSH BUTTON
DISTRIBUTION PANEL
LIGHTING PANEL
PANELBOARD CABINET, FLUSH MOUNTED
PANELBOARD CABINET, SURFACE MOUNTED
RECEPTACLE, CLOCK HANGER
RECEPTACLE, DUPLEX
RECEPTACLE, DUPLEX ON EMERGENCY POWER
RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT
INTERRUPTER
RECEPTACLE, QUADRAPLEX
RECEPTACLE, SINGLE
RECEPTACLE, SINGLE WITH SWITCH
RECEPTACLE, SWITCHED
DUPLEX
DIRECT BURIAL CABLE = DB
POWER DUCT = P
HI VOLTAGE SWITCH ON CONCRETE PAD
LOW VOLTAGE SWITCH ON CONCRETE PAD
DUAL POWER AND TELECOMMUNICATIONS MANHOLE
DROP CORD, SINGLE CONVENIENCE OUTLET, 3-WIRE,
GROUNDING TYPE, 20A, W/#12 CONDUCTORS IN FLEXIBLE
CORD (CENTER LINE OF OUTLET: 6'-6" AFF. (MINIMUM).
ELECTRICAL STRIP MOLD (OUTLETS ON 2'-0" CENTERS OR AS
DESIGNATED ON DRAWINGS), MTD 3'-6" AFF OR AS INDICATED.
3-GANG COMPARTMENT BOX IN FLOOR FOR
TELEPHONE, DATA & RECEPTACLE.
ELECTRICAL SYMBOLS - POWER PLAN
SWITCH
F = FUSED SWITCH
K = KEY OPERATED
L = LOCK
LM = LOW VOLTAGE MASTER
M = MANUAL MOTOR STARTING
MC = MOMENTARY CONTACT
MP = MOTOR SNAP WITH PILOT LIGHT
P = WITH PILOT LIGHT
(THERMAL TYPE)
PB = PUSH BUTTON STATION
RC = REMOTE CONTROL
WP = WEATHER PROOF
X = EXPLOSION PROOF
DP#__
LP
TC
S
S
LVS
P T
A
B
A
B
D
OS = INTEGRAL OCCUPANCY SENSOR
LVD = LOW VOLTAGE DIMMER
LV= LOW VOLTAGE
RECESSED DOWNLIGHT FIXTURE, LETTER
INDICATES TYPE.
LIGHT FIXTURE, RECESSED TROFFER, (2'x4');
LETTER INDICATES TYPE.
LIGHT FIXTURE, RECESSED TROFFER, (1'x4');
LETTER INDICATES TYPE.
ELECTRICAL SYMBOLS - LIGHTING PLAN
LIGHT FIXTURE, SURFACE MOUNTED TROFFER,
(2'x4'); LETTER INDICATES TYPE.
LIGHT FIXTURE, SURFACE MOUNTED TROFFER,
(1'x4'); LETTER INDICATES TYPE.
LIGHT FIXTURE, TROFFER EMERGENCY;
LETTER INDICATES TYPE.
EXIT SIGN, WALL MOUNTED WITH DIRECTIONAL
ARROWS AND
FACES AS SHOWN
EXIT SIGN, CEILING MOUNTED WITH
DIRECTIONAL ARROWS AND
FACES AS SHOWN
SWITCH, MULTIPOSITION
SWITCH, NORMALLY CLOSED FLOAT
SWITCH, NORMALLY CLOSED FOOT OPERATED
SWITCH, NORMALLY CLOSED LIMIT
SWITCH, NORMALLY CLOSED TIME DELAY
SWITCH, NORMALLY CLOSED TEMPERATURE
ACTIVATED
SWITCH, NORMALLY OPEN FLOAT
SWITCH, NORMALLY OPEN LIMIT
SWITCH, NORMALLY OPEN TEMPERATURE
ACTIVATED
SWITCH, NORMALLY OPEN TIME DELAY
SWITCH, SINGLE BREAK
FUSE WITH RATING
NORMALLY CLOSED RELAY CONTACT
NORMALLY OPEN RELAY CONTACT
MOLDED CASE CIRCUIT BREAKER
LOW-VOLTAGE DRAWOUT AIR CIRCUIT BREAKER
MEDIUM-VOLTAGE OIL CIRCUIT BREAKER
MEDIUM-VOLTAGE DRAWOUT AIR CIRCUIT BREAKER
SWITCH AND FUSE UNIT
FUSED DRAWOUT POTENTIAL TRANSFORMER
ELECTRICAL SYMBOLS - DIAGRAM
MOTOR, SINGLE-PHASE
MOTOR, THREE-PHASE
DELTA CONNECTION
TRANSFORMER
WYE CONNECTION
PULL BOX
PRESSURE SWITCH-CLOSE ON
INCREASE
PRESSURE SWITCH-OPEN ON
INCREASE
FUSIBLE LINK
VARIABLE FREQUENCY DRIVE
GENERATOR, POWER
BATTERY
CAPACITOR
LIGHTNING ARRESTOR
RECTIFIER, CATHODIC PROTECTION
RELAY; LETTER INDICATES RELAY TYPE
50 = INSTANTANEOUS OVERCURRENT OR RATE-OF-RISE
51 = AC-TIME OVERCURRENT
67 = AC-DIRECTIONAL OVERCURRENT
86 = LOCK OUT
DISCONNECT SWITCH, FUSED
DISCONNECT SWITCH, UNFUSED
STARTER, COMBINATION W/DISCONNECT SWITCH
STARTER OR MOTOR CONTROLLER
POTHEAD
STRESS CONE
AMMETER
VOLTMETER
WATTMETER
WATT-HOUR METER
PB
VFD
A
V
W
WH
T T
C C
J
W W
RC
DB
P
B B
D
C
OS
CEILING MOUNTED OCCUPANCY SENSOR,
ARROWS INDICATE COVERAGE.
RECEPTACLE, SPECIAL PURPOSE
A = 120V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 5-20R.
B = 208V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 6-20R.
C = 120V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 5-30R.
D = 208V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 6-30R.
E = 208V, 60A, 1 PHASE, 3-POLE, 4W, NEMA 14-60R.
F = 208V, 30A, 3 PHASE, 3-POLE 4W, NEMA 15-30R.
G = 208V, 50A, 3 PHASE, 3 POLE, 4W, NEMA 15-30R.
H = 208V, 60A, 3 PHASE, 3 POLE, 4W, NEMA 15-60R.
T
F
RX
ES
ML
CR
J
RRB
WS
HES 4500-12/24-630 ELECTRIC DOOR STRIKE
HID 920NHRNEK0000C PIVCLASS CARD READER
UTC 1078C-G MAGNETIC DOOR POSITION SWITCH
AXIS P3375-V VANDAL RESISTANT 1080P DOME IP CAMERA
FOUR SQUARE JUNCTION BOX
SECURITRON iMXDa MAGNETIC LOCK
USP HUB2SA REMOTE DOOR RELEASE BUTTON
BOSCH DS160 REQUEST TO EXIT MOTION DETECTOR
CCTV SYSTEM WORKSTATION
DB
HONEYWELL 270R DURESS BUTTON
CODE BLUE BUTTON INTEGRATED NURSE CALL SYSTEM
NURSE CALL MASTER CONSOLE
ETHERNET NETWORK SWITCH
WIRELESS ACCESS POINT
NWS
NCM
CB
WAP
OUTLET, COMBINATION TELEPHONE/DATA
COMMUNICATION
CABLE TELEVISION LINE = CATV
CLOSED CIRCUIT TELEVISION LINE = CCTV. MINIMUM
1" CONDUIT
FIBEROPTICS LINE = FO
FLOOR RECEPTACLE, TELEPHONE
OUTLET TELEPHONE; LETTER INDICATES AS FOLLOWS:
J = JACK TYPE W = WALL TYPE
SPEAKER, CEILING MOUNTED, "X" INDICATES THE TYPE, PROVIDE
SCHEDULE ON LEGEND
SPEAKER, WALL MOUNTED, "X" INDICATES THE TYPE, PROVIDE
SCHEDULE ON LEGEND. MTD. 7'-6"
AFF UNLESS OTHERWISE NOTED.
OUTLET DATA ONLY
TELEPHONE LINE = T
INTERCOM LINE = I. MINIMUM 3/4" CONDUIT.
SOUND LINE = S
NURSE CALL LINE = NC. MINIMUM 3/4" CONDUIT.
OUTLET; LETTER INDICATES AS FOLLOWS:
A = AUDIO V = VIDEO I = INTERCOM
RADIO CONDUIT RUN, MINIMUM 3/4" CONDUIT.
RADIO CHANNEL SELECTOR FACILITIES, MTD. 4'-6"
AFF UNLESS OTHERWISE NOTED.
SPEAKER PROGRAM SELECTOR SWITCH & VOLUME CONTROL MTD.
4'-6" AFF UNLESS OTHERWISE NOTED.
OUTLET, TELEVISION
BLANK = 4 11/16" MASTER ANTENNA OUTLET BOX W/BLANK COVER,
MTD. 18" AFF UNLESS OTHERWISE NOTED.
C = CAMERA (CCTV SYSTEM), MTD 18" AFF
M = MONITOR (CTTV SYSTEM).
NURSE'S CALL MASTER STATION MTD ON NURSE'S COUNTER TOP
UNLESS OTHERWISE NOTED.
NURSE CALL TERMINAL CABINET.
NURSE CALL STATION.
2 = DUPLICATE FACILITIES FOR TWO BEDS (SEPARATE INDICATORS
AT MASTER STATION) MTD 5'-0" AFF UNLESS OTHERWISE NOTED.
D = DUTY STATION. MTD 5'-0" AFF UNLESS NOTED OTHERWISE.
E = MTD 6'-0" AFF FOR SHOWER LOCATION, MTD 4'-6" AFF FOR TUB
LOCATION, & MTD 3'-0" AFF FOR TOILET LOCATION.
P = PSYCHIATRIC CORRIDOR STATION WITH KEY SWITCH
S = AUDIO VISUAL MALL STATION (STAFF) MTD 5'-0" AFF UNLESS
OTHERWISE NOTED.
U = UTILITY CALL STATION, MTD 5'-0" AFF UNLESS OTHERWISE
NOTED.
NURSE CALL STATION.
2 = NURSE'S CALL DOME LIGHT (SUFFIX INDICATES No OF LAMP)
MTD 6" ABOVE DOOR.
D = CORRIDOR DOME LIGHT.
I = AUXILIARY INTERSECTIONAL DOME LIGHT.
NOTE:
FOR WHEELCHAIR PATIENT USE MOUNT TELEPHONE OUTLET 36" AFF
TO BOTTOM OF OUTLET BOX.
DESK PHONES - MOUNT OUTLET 1'-6" AFF
PAY PHONES - MOUNT OUTLET 4'-0" AFF
HEIGHT OF TELECART OUTLETS SHALL BE AS INDICATED ON BEDWALLS
OR PBPU DETAILS.
SEE VA BARRIER FREE DESIGN GUIDE PG-18-13.
NATURAL GAS DETECTION LEAK MONITOR
NATURAL GAS AUDIBLE ALARM
TELEPHONE TERMINAL CABINET
TELEPHONE BACKBOARD (WALL MOUNTED)
3-POLE TWIST-LOCK RECEPTACLE FOR MICROPHONE, MTD. 4'-6" AFF.
REMOTE DICTATING OUTLET MTD 1'-6" AFF. UNLESS OTHERWISE
NOTED.
INTERCOM STATION (REFER TO SPECS. FOR FUNCTIONAL OPERATION
OF INSTRUMENT & TYPE REQUIRED).
INTERCOM STAFF STATION.
TELECOMMUNICATIONS MANHOLE
COMMUNICATION SYMBOLS:
DATA BOX
P MANHOLE
LIGHT FIXTURE, RECESSED TROFFER, (2'x2');
LETTER INDICATES TYPE.
HVS
S
NORMALLY CLOSED
CONSTRUCTION DOCUMENTS
A. ALL FINAL LOCATIONS AND ARRANGEMENTS OF LIGHTING FIXTURES SHALL BE
OBTAINED FROM THE ARCHITECTURAL REFLECTED CEILING PLAN, IF APPLICABLE.
B. EACH BRANCH CIRCUIT HOMERUN SHALL HAVE NO MORE THAN THREE CIRCUITS.
EACH BRANCH CIRCUIT HOMERUN SHALL HAVE A SEPARATE GREEN INSULATED
EQUIPMENT GROUNDING CONDUCTOR.
C. MULTI-GANG BACKBOXES FOR DIFFERENT VOLTAGES AND TYPES OF EMERGENCY
AND NORMAL BRANCH WIRING DEVICES SHALL HAVE DIVIDERS BETWEEN DEVICES.
D. ALL WIRING SHALL BE (3)#12 THWN/THHN COPPER 3/4C" UNLESS OTHERWISE NOTED.
E. MINIMUM SIZE CONDUIT FOR CONTROL CIRCUITS SHALL BE 1/2".
F. CORE DRILL AND SAW CUT, AS REQUIRED, FOR FLOOR AND WALL PENETRATIONS.
SEAL REMAINING ANNULUS WITH FIRE CAULK.
G. FURNISH ACCESS DOORS FOR INSTALLATION BY GENERAL CONTRACTOR IN WALLS
AND CEILINGS WHERE ACCESS IS REQUIRED TO CONCEALED ELECTRICAL BOXES
AND DEVICES.
H. ARMORED CABLE (AC) MAY BE USED FOR LAY-IN FIXTURE PIGTAILS. ARMORED CABLE
(AC) SHALL NOT BE USED FOR BRANCH CIRCUIT HOMERUNS. ARMORED CABLE (AC)
SHALL NOT BE USED WHERE MORE THAN THREE CONDUCTORS
(PHASE/NEUTRAL/GROUND) ARE REQUIRED, WHERE EXPOSED; OR IN LENGTHS
EXCEEDING 20 FEET EXCEPT FOR TEMPORARY WIRING.
I. PROVIDE ALL ELECTRICAL WORK IN ACCORDANCE WITH THE CURRENT NATIONAL
ELECTRICAL CODE AND THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING
JURISDICTION.
J. COORDINATE ALL OUTAGES WITH VA COR PER SPECS PRIOR TO WORK BEING DONE.
K. ALL WORK SHALL OCCUR BETWEEN THE HOURS OF 1900 FRIDAY AND 0700 MONDAY.
A. FOR EXISTING EQUIPMENT, SUCH AS LIGHTING FIXTURES, WIRING DEVICES,
CONDUITS, ETC., SHOWN ON PLANS TO BE REMOVED, COMPLETELY CUT/CAP
CONDUITS AT THE AREA OF WORK PERIMETER AND REMOVE CONDUIT WITHIN THE
WORK AREA, DISCONNECT WIRING AT THE OVERCURRENT PROTECTIVE DEVICE AND
REMOVE WIRING COMPLETELY FROM THE ABANDONED CONDUITS.
B. DISCONNECT AND REMOVE ALL WIRES AND CONDUIT BACK TO OVERCURRENT
DEVICE AND RELABEL AS SPARE.
C. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS
PASSING THROUGH RENOVATED AREAS AND SERVICING UNDISTURBED AREAS.
D. REMOVE ALL ACCESSIBLE ABANDONED WIRING OF ALL TYPES, OR CAP AND LABEL IN
JUNCTION BOX FOR RE-USE, IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE.
E. REPLACE ALL EXISTING MULTI-PHASE BRANCH CIRCUIT BREAKERS WITH HANDLE TIE
BREAKERS ON ALL MULTI-PHASE CIRCUITS.
ELECTRICAL GENERAL NOTES:
ELECTRICAL GENERAL NOTES - DEMOLITION:
KEY NOTE.
KEY NOTES:
NEW - EXISTING, & DEMO LINE TYPES:
NEW LINE TYPE.
EXISTING LINE TYPE.
DEMO LINE TYPE.
1P
AF
C
G
AutoCAD SHX Text
FIX
AutoCAD SHX Text
NCS
AutoCAD SHX Text
NCT
AutoCAD SHX Text S
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text M
AutoCAD SHX Text
TTB
AutoCAD SHX Text N
AutoCAD SHX Text
AutoCAD SHX Text N
AutoCAD SHX Text
AutoCAD SHX Text M
AutoCAD SHX Text R
AutoCAD SHX Text M
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text X
AutoCAD SHX Text S
AutoCAD SHX Text X
AutoCAD SHX Text J
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text
NC
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text
FO
AutoCAD SHX Text
CCTV
AutoCAD SHX Text
CATV
EXAM
CLEAN
EXAM
DICT
LOCKER
LOUNGE
TOILET
MICRO
REFRIG
EXAM EXAMEXAM
F36B F31
F38
F39
C32
F37
F35
F32
F33 F34
C33
OFFICE
OFFICE OFFICE
OFFICE
F36
F36DF36C
OFFICE
OFFICE
F37A
U P
U P
EXAM
B29
EXAM
B27
NURSE
TEAM
ROOM
B26
EXAM
F25
NURSE
TEAM
ROOM
F24
EXAM
F26
EXAM
F27
EXAM
F29 C33
C31
F28
STAIR
#9
C24
C31
TRANSFORMER
TR-5-3
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W
W
W
W
W W W W W W W W W W W W W W W W W W
W W
SWITCHGEAR #G1
TT
T
TTTTTTTTTT
T
T
T
T
T
T
T
T
T
BUILDING 5 GROUND FLOOR - DEMO
SCALE 1/4" = 1'- 0"
Plan North
5"5"
KEY NOTES:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
ED101
ELECTRICAL DEMO PLAN
PHARMACY GENERATOR #1
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
ELECTRICAL CONTRACTOR SHALL REMOVE GENERATOR AND ALL ASSOCIATED ACCESSORIES
INCLUDING GENERATOR, FEEDER, CONTROL WIRING, BATTERY CHARGERS AND WIRING TO THE FUEL SYSTEM. FEEDER AND BRANCH CIRCUIT WIRING AND CONDUIT ASSOCIATED WITH EQUIPMENT BEING
REMOVED SHALL BE REMOVED IN ITS ENTIRETY BACK TO THE POWER SOURCE.
MAINTAIN EXISTING GENERATOR SWITCHGEAR FOR CONNECTION TO NEW REMOTE GENERATOR.
CONTRACTOR SHALL RE-USE AND RECONFIGURE EXISTING BACKUP GENERATOR SWITCHGEAR TO
ACCOMMODATE NEW GENERATOR. CONNECTIONS TO ATS SWITCHES SHALL NOT BE DEMOLISHED.
REMOVE EQUIPMENT INDICATED.
DISCONNECT OIL PUMP SET. REMOVE CONDUIT AND WIRING IN ITS ENTIRETY BACK TO POWER
SOURCE. REMOVE ALL FUEL OIL PIPING IN ROOM. CAP BENEATH FLOOR AND RESTORE FLOOR PER
KEY NOTE 5.
FIRE SEAL HOLES THROUGH FLOOR WITH THROUGH PENETRATION ASSEMBLIES THAT MAINTAIN FIRE
RATING AND INTEGRITY OF EXISTING FLOOR.
FIRE SEAL HOLES THROUGH WALLS WITH THROUGH PENETRATION ASSEMBLIES THAT MAINTAIN FIRE
RATING AND INTEGRITY OF EXISTING WALL.
FUEL OIL SUPPLY AND RETURN PIPING BELOW PAVED/CONCRETE SURFACES TO BE CAPPED AND
ABANDONED IN PLACE. REMOVE ALL OTHER FUEL OIL SUPPLY AND RETURN PIPING.
EXISTING EXHAUST FANS AND ASSOCIATED DUCT, LOUVERS AND POWER TO REMAIN.
DEMOLISH EXISTING GENERATOR FUEL TANK WITH ASSISTANCE FROM VA AND STATE OF SOUTH
DAKOTA TANK REMOVAL PROGRAM.
GENERATOR
ROOM # B66A
UPS
BLDG 5 - GROUND FLOOR KEY PLAN
SCALE: NO SCALE
RM B66A - 5
GENERATOR
WALL
THIMBLE
FUEL CIRC PUMPS
GALLON
FUEL OIL
TANK
10"
INSULATED
EXHAUST
PIPE
WALL
MOUNTED
BATTERY
CHARGER
TWO TIERED
BATTERY
RACK
CONCRETE PAD
TO BE DEMOLISHED
CONCRETE PAD TO
REMAIN
REMOTE RADIATOR
FOR
FOS7
GENERAL NOTES:
A. FIELD VERIFY AND ADJUST EXACT ROUTING OF ALL CONDUITS WITH EXISTING CONDITIONS.
B. DISCONNECT AND REMOVE ALL WIRES AND CONDUIT BACK TO OVERCURRENT DEVICE AND
RE-LABEL AS SPARE.
C. REMOVE ALL ACCESSIBLE ABANDONED WIRING OF ALL TYPES, OR CAP AND LABEL IN JUNCTION
BOX FOR RE-USE, IN COMPLIANCE WITH NATIONAL ELECTRIC CODE.
ATS
UPS
TRANSFORMER
TR-5-7
CONSTRUCTION DOCUMENTS
1' 2' 4' 8' 16'0
GENERATOR
QH2
GENERATOR
LOUVERS
U P
U P
EXAM
B33
EXAM
B32
EXAM
B29
EXAM
B27
NURSE
TEAM
ROOM
B26F28
STAIR
#9
C24
CO
RR
ID
OR
TRANSFORMER
TR-5-3
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
P
P
P
P
SNOW MELT
CNTL
225A 480/277
MLO
SEH1
400A 480/277 MLO
CRITICAL
CEH1
400A 480/277 MLO
EM
EQUIP
1200A 480/277
SWITCH-
BOARD
#N1
480/208 112.5kVA
TRD-QH1-1
CEL1
120/208 700A
MCB
CRITICAL EM
100A 120/208
MLO LIFE
SAFETY
SEL1
M
T
TRD-SEH1-1
480/208 30kVA
QH1
350 120/208 EM
MCB
480/208 75kVA
480/208 225kVA QL1
TRD-CEH1-1
TRD-N1-1
SWITCHGEAR #1
SWITCHGEAR #G1
SW
IT
CH
GE
AR
#2
P
P
P
P
P
P
P P
P P
P P
P P P P
TT
T
TTTTTTTTTT
T
T
T
T
T
T
T
T
T
T
T
BUILDING 5 GROUND FLOOR - DEMO
SCALE 1/4" = 1'- 0"
Plan North
ATS 2 ATS 3 ATS 1
ATS 7
UPS
QH2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
ED102
ELECTRICAL DEMO PLAN
REPLACE OPEN ATS. 1, 2, 3, 7, UPS
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
B65
KEY NOTES:
GENERATOR
ROOM # B66A
ELEC
ROOM # B66
BLDG 5 - GROUND FLOOR KEY PLAN
SCALE: NO SCALE
RM B66A - 5
RM B66 - 5
CONTRACTOR SHALL REMOVE DISCONNECT, ATS, AND WIRES BACK TO BREAKER IN NORMAL AND
EMERGENCY SOURCE. MAINTAIN EXISTING FEEDER CONDUIT IN PLACE FOR EXTENSION TO NEW
LOCATION.
DEMO CONCRETE PAD. SEE SHEET ED101.
ATS
UPS
TRANSFORMER
TR-5-7
CONSTRUCTION DOCUMENTS
1 1 1
1' 2' 4' 8' 16'0
CHILLER
PLANT
ROOM #
E24
CHILLER
PLANT ROOM
# E25
CM1
CM2
M
M
M
M
M
M
M
M
M
MM
M
M
M
M
M
MCC MN5
MCC MQ2
CHILLER
MOTOR
(TYPICAL)
KEY NOTES:
BUILDING 5 GROUND FLOOR - DEMO
SCALE 1/4" = 1'- 0"
Plan North
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
ED103
ELECTRICAL DEMO PLAN
REPLACE PANEL H1
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
BLDG 5 - GROUND FLOOR KEY PLAN
SCALE: NO SCALE
RM E24 - 5
H1
CONSTRUCTION DOCUMENTS
CONTRACTOR SHALL DISCONNECT AND REMOVE PANEL H1 FOR REPLACEMENT.
PROTECT EXISTING FEEDERS FOR RECONNECTION. CONTRACTOR SHALL
COORDINATE WITH VA COR FOR OUTAGE REQUIREMENTS.
1' 2' 4' 8' 16'0
245D 245B
245C
OFFICE
STOR.
REF.
SL
P6
245E
296B
STOR.
REF.
245A
ROOM
3'-8"
MAX.
CLEAR
SPACE
3'-8"
MAX.
CLEAR
SPACE
3'-8"
MAX.
CLEAR
SPACE
3'-8"
MAX.
CLEAR
SPACE
198 198A
194A
191D
S4
ROOM
ROOM
HALLWAY
HALLWAY
ROOM ROOM
3'-8"
MIN.
CLEAR
SPACE
3'-8"
MIN.
CLEAR
SPACE
KEY NOTES:
BUILDING 5 SECOND FLOOR - DEMO
SCALE 1/4" = 1'- 0"
Plan North
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
ED104
ELECTRICAL DEMO PLAN
REPLACE PANEL P6
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
BLDG 5 - SECOND FLOOR KEY PLAN
RM 245A - 5
SCALE: NO SCALE
ELEVATION PANEL P6 - LOOKING WEST
SCALE: NO SCALE
COLUMN
2" BRANCH RC
2.5"
FEEDER
RC
CONSTRUCTION DOCUMENTS
PANEL SL
PANEL SL
ELEVATION PANEL SL
SCALE: NO SCALE
(VIEW LOOKING EAST) (SOUTH
SIDE VIEW)
CONTRACTOR SHALL DISCONNECT AND REMOVE PANEL SL AND ALL FEEDERS BACK TO SOURCE
AND CONDUIT TO FLOOR AND CAP.
CONTRACTOR SHALL DISCONNECT AND REMOVE PANEL P6, ALL FEEDERS BACK TO SOURCE AND
OCPD AT SOURCE. ALL FEEDER AND DISTRIBUTION CONDUIT SHALL REMAIN. ALL BRANCH CIRCUITS
SHALL REMAIN FOR FUTURE RE-USE.
CONTRACTOR SHALL REMOVE 2.5" EMC FROM PANEL SL BACK TO SB 5-1 AND REMOVE PANEL S6.
CONTRACTOR SHALL REUSE CONDUIT THAT IS PENETRATING FLOOR TILE.
CONTRACTOR SHALL INSTALL ICRA BOUNDARY LEVEL 2 PRIOR TO CONSTRUCTION AND IT SHALL
REMAIN IN PLACE DURING ALL CONSTRUCTION IN KITCHEN.
PANEL SL
CONDUIT
W/LB
(NORTH
SIDE VIEW)
TRAY CONVEYER
PANEL P6
2.5" EMC
1' 2' 4' 8' 16'0
BUILDING 5 FIRST FLOOR - DEMO
SCALE 1/4" = 1'- 0"
Plan North
1' 2' 4' 8' 16'0
4 3
ED104
ED104
ATTIC AREA
527528
ATTIC AREA
ROOF
ATTIC AREA
CHASESHOWER
527A
ATTIC AREA
MED VAC
MED AIR
AHU18
AHU35
AHU19
AHU32
R
O
O
F
H
A
T
C
H
RC RC
RC RC
PANEL
SL
TO BLDG. 24
PANEL MDP
SL
VFD
DISCONNECT
TRANSFORMER
DISCONNECT
225 KVA
CHILLER
STEP UP
TRANSFORMER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
ED105
ELECTRICAL DEMO PLAN REFEED
5TH FLOOR CHILLER TRANSFORMER
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
CONTRACTOR SHALL DEMO EXISTING GE 400A BREAKER THAT FEEDS 225KVA STEP-UP
TRANSFORMER FOR CHILLER.
KEY NOTES:
BUILDING 5 5TH FLOOR, WEST SIDE - DEMO
SCALE 1/8" = 1'- 0"
Plan North
BLDG 5 - FIFTH FLOOR KEY PLAN
SCALE: NO SCALE
RM 529 - 5
CONSTRUCTION DOCUMENTS
2' 4' 8' 16' 32'0
07/06/2018
AutoCAD SHX Text S
LADDER UP
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
ED106
ELECTRICAL DEMO PLAN REFEED
ELEV. TRANS. FROM MCC-PP10
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
CONSTRUCTION DOCUMENTS
SCALE 1/4" = 1'- 0"
Plan North
ROOM #601
B
ROOM
#600A
REFRIGERATION
MACHINE
ACR-15
AIR
COMPRESSOR
PUMPS
P8
ROOM #601
A
ROOM
#600A
MCC PP10
REFRIGERATION
MACHINE
ACR-15
AIR
COMPRESSOR
PUMPS
EXP. TANK
BUILDING 5 SIXTH FLOOR - DEMO
SCALE 1/4" = 1'- 0"
Plan North
UP
DN
BLDG 5 - SIXTH FLOOR KEY PLAN
SCALE: NO SCALE
RM 600 - 5
C
D
LADDER UP
AHU17
IT
CABINETS
SECONDARY
DISCONNECT
1' 2' 4' 8' 16'0
DISCONNECT AND REMOVE PRIMARY FEEDER AND CONDUIT FROM BUS OF PANEL P8 TO
TRANSFORMER. COORDINATE SHUTDOWN OF ELEVATOR TRANSFORMER AND PANEL P8 48
HOURS PRIOR TO DE-ENERGIZING.
KEY NOTES:
ROOM
#600
07/06/2018
ELEVATOR
TRANSFORMER
PANEL
PROCEDURE
TELEPHONE
EMS
STOR. EXAM
CORRIDOR
EXAMSTOR.
EXAM
EXAM
CORRIDOR
EXAM
C22
C25
B62
B34
B23 B28
B30
B31
B22
B21
F22
F46
F18
F51F50
OFFICE
LOCKER
U P
U P
EMERGENCY DIST
SWBD 56-G1
ATS 8
W W
W W
W W
W W
W W
W W
W W
W W
W
W
W W W W W W W W W W W W
P P
P
P P
P
P
P
P
P P
P P
P
P
P
P P
P P P
P
P
P
W W
TRANSFORMER TR-5-3
P
S
P P
P P
P P P P P P P
S
T
TTTTTT
T
T
T
T
T
T
T
T
T
T
P
P P
P
P
P P
P P
P P
P
P
P
SNOW
MELT
CNTL
225A 480/277
MLO
SEH1
400A 480/277
MLO CRITICAL CEH1
400A 480/277
MLO EM EQUIP
1200A 480/277
SWITCH-
BOARD
#N1
480/208 112.5kVA
TRD-QH1-1
CEL1
120/208 700A MCB
CRITICAL EM
100A 120/208
MLO LIFE SAFETY
SEL1
M
CRITICAL
BR
EQUIP.
BR
480V
LIFE
SAFETY
480V
CRITICAL
BR
T
TRD-SEH1-1
480/208 30kVA
QH1
350 120/208
EM MCB
480/208 75kVA
480/208 225kVA
QL1
TRD-CEH1-1
TRD-N1-12
SWITCH-
GEAR #1
SWITCH-
GEAR #G1
SWG
#2
NEW 800KW GENERATOR WITH UL 142, 1455 GAL BASE TANK AND SOUND ATTENUATED
SKID BASE ENCLOSURE.
SEE DRAWING E-501 FOR DUCT BANK DETAIL.
CONTRACTOR SHALL TEST THE NEW BACK-UP GENERATOR COORDINATION FROM VA
ENGINEERING AND ELECTRICAL STAFF PRIOR TO ACCEPTANCE. REFER TO SPECIFICATIONS.
PROVIDE 48" x 48" x 12" JUNCTION BOX ON EXTERIOR WALL FOR TRANSITION FROM
UNDERGROUND TO OVERHEAD DISTRIBUTION TO EXISTING SWITCHGEAR #G1.
MODULAR STAIRWELL PROVIDED BY GENERATOR MANUFACTURER. VERIFY EXACT LOCATION PRIOR TO
INSTALLATION.
KEY NOTES:
BUILDING 5 GROUND FLOOR - POWER
SCALE 1/8" = 1'- 0"
Plan North
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
EP101
ELECTRICAL POWER PLAN
PHARMACY GENERATOR #1
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
MED
GAS
G16A
G16
B65
ENTRY
C23
ELEC
ROOM # B66
GENERATOR
ROOM # B66A
OFFICE
B35
EXAM
B33
EXAM
B32
EXAM
B29
EXAM
B27
C2
NURSE
TEAM
ROOM
B26
EXAM
F25
NURSE
TEAM
ROOM
F24
PROCEDURE
F23
EXAM
F26
EXAM
F27
EXAM
F29
CO
RR
ID
OR
C33
STAIR #9
F28
C31 C31
EXAM
F31
CORR.
C33
DICT
LOUNGE
LOCKER
OFFICE OFFICE OFFICE
OFFICE
F37AOFFICE
F36C
OFFICE
F36D
C32
BLDG 5 - GROUND FLOOR KEY PLAN
SCALE: NO SCALE
RM B66A - 5PHARMACY
POWER BUILDING
FUEL STORAGE
TANK
EXAM
F38
F39
NURSE TEAM
ROOM
EXAM
F40
EXAM
F41
EXAM
F42
EXAM
F43
EXAM
F44
F34F33
UPS
EMERGENCY
EQUIPMENT
BRANCH
PANEL QH2
CONSTRUCTION DOCUMENTS
TRANSFORMER
TR-5-7
2' 4' 8' 16' 32'0
2 4
EP102
5 (TYP)
AutoCAD SHX Text
EMERGENCY
AutoCAD SHX Text B36
AutoCAD SHX Text W
AutoCAD SHX Text W
S
S
UPS
QH2
ELEC
ROOM
# B66
GENERATOR
ROOM # B66A
EMERGENCY
DIST. SWBD
56-61
S
ATS 1
JOHNSON
CONTROLS
SNOW
MELT
CNTL
225A 480/277
MLO
SEH1
400A 480/277
MLO CRITICAL CEH1
120/208 700A MCB
100A 120/208
MLO LIFE SAFETY
SEL1
M
MATASYS
T
TRD-SEH1-1
480/208 30kVA
SWITCHGEAR #1
120/208 700A
MCB CRITICAL EM
SW
IT
CH
GE
AR
#2
TRANSFORMER
TR 5-3
P P P
P P
P P
P
P
P P
P P
P
P P
P P
P P
P
P P
P
P P
P P
P P
P P
P P
P P P P P P P P
ATS 3
ATS
ATS 7
ATS 2
UPS
P P
P P P P P
KEY NOTES:
BUILDING 5 GROUND FLOOR - POWER
SCALE 1/4" = 1'- 0"
Plan North
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
EP102
ELECTRICAL POWER PLAN
REPLACE OPEN ATS. 1, 2, 3, 7, UPS
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
BLDG 5 - GROUND FLOOR KEY PLAN
SCALE: NO SCALE
RM B66A - 5
EXISTING EMERGENCY DISTRIBUTION SWITCHBOARD SHALL BE RECONFIGURED AND
REUSED TO FEED NEW ATS SWITCHES AND CONTROL NEW GENERATOR AND EXISTING
JOHNSON CONTROL PANEL.
EXTEND EXISTING PAD TO ALLOW PLACEMENT OF NEW ATS 1, 2, 3, 7 AND UPS. MATCH NEW
CURB HEIGHT TO EXISTING CURB.
SEE DETAIL SHEET E-501 FOR CONDUIT TRAPEZE MOUNTING DETAIL.
PROVIDE FIRE CAULKING TO MATCH WALL RATING FOR ALL WALL PENETRATIONS.
EXTEND NORMAL AND LOAD FEEDERS FROM PREVIOUS ATS LOCATION TO AREA SHOWN.
REFER TO E-601 FOR MORE INFORMATION.
PROVIDE NEW EMERGENCY FEEDERS FROM DIST. SWBD 56-G1 TO NEW ATS LOCATION.
REFER TO E-601 FOR MORE INFORMATION.
PROVIDE NEW GENERATOR FEEDERS OVERHEAD TO PULL-BOX LOCATION, THEN
TRANSITION DOWN WALL TO DUCT BANK. REFER TO E-601 FOR MORE INFORMATION.
PROVIDE NEW ATS PER SHEET E-601, KEY NOTE 1.
CONSTRUCTION DOCUMENTS
80" MIN
70" MIN
1' 2' 4' 8' 16'0
AutoCAD SHX Text W
H1
CHILLER
PLANT
ROOM #
E24
CM2
M
M
M
M
M
M
M
M
MM
M
M
M
M
M
M
MCC MN5
MCC MQ2
CHILLER
MOTOR
(TYPICAL)
MINIMUM
KEY NOTES:
BUIDLING 5 GROUND FLOOR - POWER
SCALE 1/4" = 1'- 0"
Plan North
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
EP103
ELECTRICAL POWER PLAN
REPLACE PANEL H1
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
CHILLER PLANT
ROOM # E24
CHILLER PLANT
ROOM # E25
CM1
BLDG 5 - GROUND FLOOR KEY PLAN
SCALE: NO SCALE
RM E24 - 5
CONSTRUCTION DOCUMENTS
CONTRACTOR SHALL DISCONNECT AND REMOVE PANEL H1 AND REPLACE WITH NEW PANEL H1
WITH TEYH-35 KAIC RATING. MATCH EXISTING BUS RATING, VOLTAGE, AND BRANCH CIRCUIT
BREAKERS. PROVIDE NEW TYPE WRITTEN PANEL DIRECTORY.
PLACE PANEL 31" AWAY FROM THE EDGE OF COLUMN TO MAINTAIN CLEARANCE FOR
NFPA/NEC.
31"
20"
5.75"
1' 2' 4' 8' 16'0
245D 245B
OFFICEREF.
245A
ROOM
KEY NOTES:
BUILDING 5 SECOND FLOOR - POWER
SCALE 1/4" = 1'- 0"
Plan North
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
EP104
ELECTRICAL POWER PLAN
REPLACE PANEL SL
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
BLDG 5 - SECOND FLOOR KEY PLAN
RM 245A - 5
SCALE: NO SCALE
ELEVATION PANEL, LOOKING WEST - P6
SCALE:NO SCALE
COLUMN
2" RC
CONSTRUCTION DOCUMENTS
CONTRACTOR SHALL PROVIDE NEW PANEL AS SHOWN. INSTALL ALL EXISTING CABLES AND
CONDUIT INTO NEW PANEL P6.
CONTRACTOR SHALL REFEED TRAY CONVEYOR BUS WHERE PANEL SL WAS PREVIOUSLY USING
6# 12 AWG-10 #8.
REFEED PANEL P6 TO SWITCHBOARD #N2 USING 2 - 2 1/2" RC AND 4-3 AWG CONDUCTORS.
SEE DETAIL E-501 FOR FLOOR PENETRATION DETAIL.
SEE DETAIL E-501 FOR TRAPEZE MOUNTING DETAIL.
PANEL P6
P6
2.5"
EMC
2.5"
EMC IN
FLOOR/RAISED
CEILING OF
FIRST FLOOR
60" L X 20"W
1' 2' 4' 8' 16'0
EP104
DN
UP
KEY NOTES:
BUILDING 5 SIXTH FLOOR - POWER
SCALE 1/4" = 1'- 0"
Plan North
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
EP105
ELECTRICAL POWER PLAN REFEED
ELEV. TRANS. FROM MCC-PP10
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
BLDG 5 - SIXTH FLOOR KEY PLAN
SCALE: NO SCALE
REFRIGERATION
MACHINE ACR-15
AIR
COMPRESSOR
PUMPS
EXP. TANK
RM 600 - 5
CONSTRUCTION DOCUMENTS
PANEL
P8
MCC PP10
IT
CABINETS
ELEV. XFMR
208/480 112.5kVA
SECONDARY
DISCONNECT
1' 2' 4' 8' 16'0
PP10 PP10
BLANK
BLANK BLANK BLANK
BLANK
ELEVATION PANEL - MCC-PP10
NO SCALE
NEW 400A
FEEDER
BREAKER
ELEVATION ELEVATOR TRANSFORMER
NO SCALE
P8
ELEVATOR
DISCONNECT
ELEVATOR
TRANSFORMER
MCC-
PP10
EP105
EP105
CONTRACTOR SHALL INSTALL ALL EXISTING CABLES AND CONDUIT INTO MCC-PP10
BUCKET AND INSTALL 800A BREAKER.
SEE DETAIL SHEET E-501 FOR CONDUIT TRAPEZE MOUNT DETAIL.
C
MH-12
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
EP106
ELECTRICAL POWER PLAN FEED
TO 225 KVA TRANSFORMER
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
ATTIC AREA
ROOF
ATTIC AREA
527A
ATTIC AREA
MED VAC
MED AIR
AHU18
AHU35
AHU19
R
O
O
F
H
A
T
C
H
KEY NOTES:
BUILDING 5 FIFTH FLOOR - POWER - EAST
SCALE 1/8" = 1'- 0"
Plan North
BLDG 5 - FIFTH FLOOR KEY PLAN
SCALE: NO SCALE
RM 529 - 5
RC RC RC RC RC RC RC
RC
RC
RC
CONSTRUCTION DOCUMENTS
RC
PANEL
SL
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
BLDG 24
BLDG 24
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
RC
VFD
RC
RC
RC
RC
RC
RC
RC
TO
EP107
2' 4' 8' 16' 32'0
07/06/2018
TRANSFORMER
DISCONNECT
PROVIDE NEW CONDUCTORS AND CONDUIT PER E-604.
CONTINUATION ON EP107.
EXISTING 225 KVA STE-UP CHILLER TRANSFORMER 208 TO 480 VOLT 3 PHASE, REFEED BACK TO
SB-5-1 ON FIRST FLOOR.
SEE CONDUIT TRAPEZE MOUNT DETAIL ON SHEET E-501 FOR MORE DETAIL.
SEE CONDUIT EXPANSION JOINTS CROSSING DETAIL ON E-501 FOR MORE DETAIL WHERE CONDUIT
CROSSES OVER ALL EXPANSION JOINTS.
AutoCAD SHX Text S
D N
U P
D40 D41
D39A
U P
E01
C14
E08B
E10
E12
E09
ST.#3
C30
D
NU
P
C12
C13E10A
E12A
020021
HISTOLOGY
CONF.
C16
TLT.
TLT.
ELEC EMS
DISTRIBUTION
STOR
ELECTRIC
CHASE
D39
D39B
D
C
B
A
U P
ELEVATORS
ROOM
SB 5-20
SB 5-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
EP107
ELECTRICAL POWER PLAN FEED
TO 225 KVA TRANSFORMER
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
KEY NOTES:
BUILDING 5 FIFTH FLOOR - POWER - WEST
SCALE 1/8" = 1'- 0"
Plan North
BLDG 5 - FIFTH FLOOR KEY PLAN
SCALE: NO SCALE
506A
506B
506C
506 507
506D 506E
506F
506G
506H
A
B
C
D
505A
#3
508B 508A
ELECTELE
H.K.
502 510
MEN
WOMEN
521523
STORAGE
H.K.
CHART
ICE
ROOM
BREAK
6C
STOR
SURG
526A
RECORDS
ENG
HATCH
ROOF
526B
SURG
STOR
ATTIC AREA
AHU32
CHASESHOWER
527A
ELEVATORS
RC
RC
RC
RC
RC
RC
RC
RC
RC RC RC RC RC
RC RC RC RC RC
RC RC RC RC
RC RC RC RC
PIPE
CHASE 5-6
5-1
P-2
P-3
510A
CONSTRUCTION DOCUMENTS
RC RC
RC
FROM
EP106
2' 4' 8' 16' 32'0
07/06/2018
PIPE
CHASE
BUILDING 5 GROUND FLOOR
SCALE 1/8" = 1'- 0"
Plan North
2' 4' 8' 16' 32'0
RC
RC
RCRCRC
BLDG 5 - GROUND FLOOR KEY PLAN
SCALE: NO SCALE
RM E01 - 5
4 3
PROVIDE NEW CONDUCTORS AND CONDUIT PER E-604.
CONTINUATION ON EP106.
CHASE GOES TO ROOM E-401 TO SB-5-1 ON GROUND FLOOR.
SEE CONDUIT TRAPEZE MOUNT DETAIL ON SHEET E-501 FOR MORE DETAIL.
SEE FLOOR SLAB PENETRATION DETAIL ON SHEET E-501 FOR MORE DETAIL ON
CONDUIT PENETRATIONS BETWEEN FLOORS.
FIRE CAULK WALL PENETRATION TO MATCH FIRE RATING OF WALL.
AutoCAD SHX Text
P.A.R. (RECOV. ROOM)
AutoCAD SHX Text S
E125
ROOF
E124
4" CONDUIT
AHU01 AHU02
PV
C PVC PVC
LCE6
GROUND
BAR
CHAIN
LINK
WORKBENCH
FI
RE
C
AB
IN
ET
4" CONDUIT
PVC PVC
CRAWL SPACE
CRAWL SPACE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
EP108
ELECTRICAL POWER PLAN E125
PBX ROOM GROUND
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
KEY NOTES:
BUILDING 5 FIRST FLOOR
SCALE 3/16" = 1'- 0"
Plan North
PROVIDE 1-#2 GROUND AND AND CONNECT TO EXISTING BUILDING
GROUND SYSTEM THROUGH CONDUIT SLEEVE INTO CRAWL SPACE.
BLDG 5 - FIRST FLOOR KEY PLAN
SCALE: NO SCALE
CONSTRUCTION DOCUMENTS
RM E125 - 5
BUILDING 5 CRAWL SPACE
SCALE 3/16" = 1'- 0"
Plan North
BLDG 5 - CRAWL SPACE KEY PLAN
SCALE: NO SCALE
CRAWL
SPACE
1'-6" 3' 6' 12' 24'0
1'-6" 3' 6' 12' 24'0
07/06/2018
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
EK101
ELECTRICAL GROUNDING
PHARMACY GENERATOR #1
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
GROUND ROD FOR EARTH GROUND
CONNECT TO BUILDING
GROUNDGROUND
CABLE
REFERENCE
NEC 250-52(C)
8 FOOT
MINIMUM
GENERATOR
GROUND
LUG
CONSTRUCTION DOCUMENTS
BLDG 5 - GROUND FLOOR KEY PLAN
SCALE: NO SCALE
GENERATOR
TYPICAL GROUNDING DETAIL
NTS
NEW #3Ø CU G IN 1 12" NONMETALLIC CONDUIT. BOND GROUND WIRE AT BOTH ENDS OF
CONDUIT RUN.
KEY NOTES:
REBAR
GROUNDING
ELECTRODE
CONDUCTOR
GROUNDING
ELECTRODES
GROUNDING
CONDUCTOR
INTERCONNECTING
GROUNDING
ELECTRODES BELOW
GRADE
EFFECTIVELY
GROUNDED
BUILDING
STEEL
EQUIPMENT
PANEL
ANTENNA
DISCHARGE
UNIT
TGB
ANTENNA
HEADED
EQUIPMENT
ROOM
ELECTRICAL
SERVICE
EQUIPMENT
OR METER
CABINET
MAIN
ELECTRICAL
DISTRIBUTION
PANEL
ELECTRICAL
ENTRANCE
INTERSYSTEM BONDING
TERMINATIONS FOR
CONNECTING
INTERSYSTEM BONDING
CONDUCTORS
TMGB
BASKET
TYPE
CABLE
TRAY
TELECOMMUNICATIONS ROOM
RACKS
OR
CABINETS
ELEC.
PANEL
TGB
GROUND
PRIMARY
CABLE
PROTECTORS
DEMARC
DEMARC
ROOM
(TELECOMMUNICATIONS
ENTRANCE
FACILITY)
TELECOMMUNICATIONS ROOM
ROOF
CONDUIT SLEEVES
(TYP.)
TELECOMMUNICATIONS
BONDING BACKBONE
BONDING CONDUCTOR
TELECOMMUNICATIONS
TELECOMMUNICATIONS
MAIN GROUNDING BUSSBAR
PRIMARY
PROTECTION
GROUNDING
CONDUCTOR
RAISED
FLOOR
ANTENNA MAST (TYP.)
TELECOMMUNICATIONS
BONDING
BACKBONE
TELECOMMUNICATIONS BONDING BACKBONE
GROUNDING EQUALIZER
ELEC.
PANEL
TGB
CONDUIT SLEEVES
(TYP.)
ELEC.
PANEL
TGB
CONDUIT SLEEVES
(TYP.)
ELEC.
PANEL
TGB
CONDUIT
SLEEVES
(TYP.)
ELEC.
PANEL
TGB
CONDUIT
SLEEVES
(TYP.)
ELEC.
PANEL
TGB
CONDUIT
SLEEVES
(TYP.)
TELE ROOM #E125
TELECOMMUNICATIONS ROOM
TELECOMMUNICATIONS ROOM
TELECOMMUNICATIONS ROOM
ELECTROSTATIC DISCHARGE FLOORING (TYP.)
TELECOMMUNICATIONS
GROUNDING BUSSBAR
(TYP. 7)
CRAWL
SPACE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
EK102
ELECTRICAL GROUNDING
E23 PBX ROOM GROUND
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
CONSTRUCTION DOCUMENTS
CONTRACTOR SHALL ADD ONE #2 AWG CABLES TO EXISTING GROUND BAR AND ADD
GROUND TO BUILDING GROUND IN ROOM E125 TO CREATE GROUND TO STRUCTURAL
STEEL IN CRAWL SPACE BELOW. SEE DRAWING E-502 FOR MORE DETAILS.
SEE E-502 FLOOR PENETRATION DETAIL.
KEY NOTES:
BLDG 5 - FIRST FLOOR KEY PLAN
SCALE: NO SCALE
RM E125 - 5
G
N
EXISTING GROUNDING
ELECTRODE CONDUCTOR TO
EXISTING GROUND ELECTRODE
SYSTEM
EMERGENCY SWBD 56-G1
1200A, 480V, 3PH, 4W, SC Rating 65kA
(1) 1/OAWG
(1) #3/0AWG
(NEW) ATS1
TGB
RM B66A
(1) #3/0AWG
(1) #3/0AWG
(NEW) ATS2
(1) #3/0AWG
TGB
(NEW) ATS3
(1) #3/0AWG
TGB
(1) #3/0AWG
(NEW) ATS7
(1) #3/0AWG
TGB
(1) 1/0AWG
(NEW) ATSUPS
TGB
(1) #3/0AWG
GROUND LOOP
EAST CLIN. ADDN. NORM. SWGR. 1
480 V, 1600 A SC Rating 50 kA < 17625 A >
GROUND BAR
(1) #3/0AWG
(1) #3/0AWG
RM B66
(1) 1/0AWG
QH2
TGB
(1) 1/0AWG
(1) #3/0AWG
SEH1
TGB
(1) #3/0AWG
(1) #3/0AWG
(1) #3/0AWG
CEH1
TGB
(1) #3/0AWG (1) #3/0AWG
(1) #3/0AWG
QH1
TGB
(1) #3/0AWG
(1) #3/0AWG
DPCEH2
TGB
(1) #3/0AWG
(1) #3/0AWG
(1) #3/0AWG
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
EK103
ELECTRICAL GROUNDING
REPLACE OPEN ATS 1, 2, 3, 7, UPS
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
GROUNDING ONE-LINE DIAGRAM
NTS
CONSTRUCTION DOCUMENTS
PANEL FE1
480 - 208Y
15 KVA
#6 IN 1/2" PVC
20/3
PANEL 'H1'
GROUND
ELECTRODE
BUS BAR
TO LIGHTNING
PROTECTION
SYSTEM
CONCRETE ENCASED
ELECTRODE
#3/0
TO BLDG.
STEEL
PANEL P6
#3/0#6
#6
CONCRETE
ENCASED
ELECTRODE
GROUND
ELECTRODE
BUS BAR
NORMAL POWER
SERVICE SWBD & N2
TR-1
BLDG 5 SERVICE SWBD 5-2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
EK104
ELECTRICAL GROUNDING
REPLACE PANELS H1 & P6
AE ELECTRICAL DEFICIENCIES
CAMPUS WIDE (SF)
4801 LINWOOD BLVD., KANSAS CITY, MO 64128
438-18-101
B5
07/06/2018 TL JMBVEG 18.1
2501 W. 22ND STREET, SIOUX FALLS, SD 57117-5046
ELECTRICAL KEY NOTES:
PANEL P6 REPLACED, CONTRACTOR SHALL INSTALL NEW #6 GROUND AND ALL CONDUCTORS TO
SWITCHBOARD 5-2.
REPLACE EXISTING H1 WITH NEW PANEL AND REPLACE GROUND TO PANEL USING TAPS.
CONSTRUCTION DOCUMENTS
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text P
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text P
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text P
EMERGENCY
DIST. SWBD
56-G1
W W
W W
W W
W W
W W
W
W
W
W W W W W W W W W W
W W
W
U P
U P
P
P
S
T
T
T
T
T
T
T
T
T
T T T T T T
T T
T T
T T T T T T
T
T T
T
T
T T
T T
T T
T
T
T
S
T
USE EXISTING SWITCH BOARD G1 AND EXISTING JOHNSON CONTROLS AND METASYS TO CONTROL
GENERATOR AND SEND STATUS TO BUILDING 11.
SEE DRAWING E-501 FOR DETAILS ON CONDUIT TRAPEZE MOUNTING.
SEE DRAWING E-501 FOR DETAIL ON DUCT BANK.
KEY NOTES:
BUILDING 5 GROUND FLOOR - NEW WORK
SCALE 1/8" = 1'- 0"
Plan North
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 WEST HAMPDEN AVENUE
SUITE 300
LITTLETON, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
ET101
ELECTRICAL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.