BUILDING-126.pdf

PDF 10 MB Posted

Attached to
Site-Wide HVAC Compliance Upgrade for RME
Solicitation number
36C26224B0009
Issued by

About this file

This federal contract opportunity is for a site-wide HVAC compliance upgrade for reusable medical equipment at Department of Veterans Affairs facilities. The solicitation seeks proposals to upgrade heating, ventilation, and air conditioning systems to meet compliance standards at multiple locations under Veterans Integrated Service Network 22. Offerors should respond to solicitation number 36C26224B0009 by the unspecified deadline to provide replacement HVAC equipment, installation services, and compliance verification for reusable medical device processing areas. The Veterans Health Administration aims to address HVAC deficiencies through this opportunity in order to properly sanitize reusable medical equipment for veteran patients.

View the file

Other files

File Type Posted
BUILDING-161.pdf PDF
BUILDING-1.pdf PDF
BUILDING-2.pdf PDF
BUILDING-7.pdf PDF
36C26224B0009 0001.pdf PDF
RFIs Final.docx DOCX document
P01 Drawings 600-17-118.pdf PDF
P07 WRD.pdf PDF
P01 Specifications 600-17-118.pdf PDF
S02 Solicitation 36C26224B0009.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TRIENNIAL ASBESTOS REINSPECTION REPORT

BUILDING 126 – MAIN HOSPITAL BUILDING

PREPARED FOR

Mr. James Bachman & Ms. Olivia Parducho

Department of Veterans Affairs VA Long Beach Healthcare System

5901 East 7th St.

Long Beach CA 90815

Contract Number: GS-10F-0229U - Order Number: VA262-14-F-7064

PREPARED BY

Millennium Consulting Associates 620 Contra Costa Boulevard, Suite 102

Pleasant Hill, CA 94523

May 15, 2015 Millennium Project No. 22015.2033

Millennium Consulting Associates 2 Project No. 22015.2033

Table of Contents

1.0 EXECUTIVE SUMMARY

2.0 INTRODUCTION

2.1 SCOPE OF WORK

2.2 SAMPLING METHODS, PROCEDURES AND PERSONNEL

2.2.1 Review of Procedures: Asbestos Inspection, Bulk Sampling, Laboratory Information and Risk Assessment

3.0 BUILDING SUMMARY

4.0 SURVEY RESULTS

4.1.1 Summary of Previous Sampling Events

4.1.2 FINDINGS OF MILLENNIUM 2014 TRIENNIAL SURVEY & ASSESSMENT

5.0 CONCLUSIONS AND RECOMMENDATIONS

6.0 LIMITING CONDITIONS

Appendices Asbestos Laboratory Sample Data ............................................................................................................... Appendix A

Asbestos Finish schedule & Hazard Assessment ...................................................................................... Appendix B

Sample Location Maps .................................................................................................................................... Appendix C

Millennium Consulting Associates 3 Project No. 22015.2033

1.0 EXECUTIVE SUMMARY

Millennium Consulting Associates (Millennium) performed comprehensive triennial asbestos survey for the VA Medical Center in Long Beach, California under Contract No. VA262-14-F-7064. The objective of this project is to support the Operations & Maintenance Program be conducting the following tasks:

Review VA-supplied previous Asbestos Survey, Assessment and abatement records;

Conduct a comprehensive site evaluation of accessible locations within each specified building to, identify, assess & evaluate condition(s) and collect representative bulk samples of previously un-sampled or newly observed PACM, suspect ACCM, and suspect ACM;

Provide an asbestos health risk assessment and determine location and quantity estimates of ACCM and ACM.

A summary of the survey final results are incorporated into this report, providing a means for the VA to more efficiently plan for repairs, renovations and/or demolition projects.

Table 1, below, summarizes the positive Asbestos survey results from this project for Building 126 – Main Hospital Building.

This is only a list of sample locations. See attached Finish Schedule for all locations of all materials.

Table 1. Survey Summary of Positive Asbestos ACM Results reported by Millennium for Building 126.

Sample No. Sample Location Material Type Color Approx.

Qty.

Asbestos Content / Type

VALB-126-F2.1 ROOM E236 12X12 RESILIENT

FLOOR TILE WHITE 1

<1 Chrysotile

VALB-126-F4.1 ROOM CC11-2 12X12 RESILIENT

FLOOR TILE

SEAFOAM BLUE 1

<1 Chrysotile

VALB-126-F4.2 ROOM W132 12X12 RESILIENT

FLOOR TILE

SEAFOAM BLUE 1

<1 Chrysotile

VALB-126-F4.3 ROOM EC-C6 12X12 RESILIENT

FLOOR TILE

SEAFOAM BLUE 1

<1 Chrysotile

VALB-126-F5.1 ROOM 632 12X12 RESILIENT

FLOOR TILE NAVY BLUE 1

<1 Chrysotile

VALB-126-F6.1 ROOM 1040 12X12 RESILIENT

FLOOR TILE MAUVE 1

<1 Chrysotile

VALB-126-F6.2 ROOM CC-10-8 12X12 RESILIENT

FLOOR TILE MAUVE 1

<1 Chrysotile

VALB-126-F6.3 ROOM CC-10-5 12X12 RESILIENT

FLOOR TILE MAUVE 1

<1 Chrysotile

Millennium Consulting Associates 4 Project No. 22015.2033

Sample No. Sample Location Material Type Color Approx.

Qty.

Asbestos Content / Type

VALB-126-F7.1 ROOM EC-C2 12X12 RESILIENT

FLOOR TILE RUST 1

2% Chrysotile

VALB-126-F7.1 ROOM EC-C2 12X12 RESILIENT

FLOOR TILE

MASTIC RUST 1

4% Chrysotile

VALB-126-F8.1 ROOM 356A 12X12 RESILIENT

FLOOR TILE BROWN 1

2% Chrysotile

VALB-126-F8.2 ROOM W160 12X12 RESILIENT

FLOOR TILE BROWN 1

2% Chrysotile

VALB-126-F8.3 ROOM W108 12X12 RESILIENT

FLOOR TILE BROWN 1

2% Chrysotile

VALB-126-F8.3 ROOM W108 12X12 RESILIENT

FLOOR TILE

MASTIC BROWN 1

4% Chrysotile

VALB-126-F14.1 ROOM W213 12X12 RESILIENT

FLOOR TILE BLACK 1

2% Chrysotile

VALB-126-F14.1 ROOM W213 12X12 RESILIENT

FLOOR TILE

MASTIC 2 BLACK 1

6% Chrysotile

VALB-126-M5.2 ROOM 1131 FIRESTOP - JOINT

COMPOUND BLUE 1

<1 Chrysotile

VALB-126-C1.1 ROOM 9FAC4 CEILING

WALLBOARD

JOINT

COMPOUND - BEIGE 1

<1 Chrysotile

VALB-126-C1.2 ROOM 11TH

FLOOR ELEC

CEILING

WALLBOARD

JOINT

COMPOUND WHITE 1

2% Chrysotile

VALB-126-C1. ROOM 10FAC1 CEILING

WALLBOARD

JOINT

COMPOUND WHITE 1

<1 Chrysotile

VALB-126-R3.1 11TH FLOOR

ROOF

PENETRATION

CENTER

PENETRATION

MASTIC BLACK 1

2% Chrysotile

VALB-126-R6.1 2ND FLOOR

ROOF WEST

PENETRATION

MASTIC

BLACK/GRAY BLACK 1

Millennium Consulting Associates 5 Project No. 22015.2033

Table 2. Summary of Previously Reported Asbestos Containing Materials for Building 126 as reported by others. The presence of ACM materials noted in this table is NOT indicative of the current presence as many of these components have been abated. Please refer to Appendix B.

Data Source Location Asbestos Type

Asbestos Quantity

Material Description Color

Friable

ACBM

Concord Analysis, 1997

Ceiling cavities/mechanical chases throughout

Chrysotile Unreported

Thermal System

Insulation on piping

Beige/white/gray Friable

Concord Analysis, 1997 and H2, 2011

E115, E131, E170, E170, E153, E149, ER Waiting Room, W128, W131, W170, W231V, W231S, E222, E227, E223A, 2nd Flrr Corridor C2-2- 2, Rm 227, , E231, E247, , W231V, !st Fl W102, W105,, E167, , W128F, W128C, W128L, W128

Chrysotile Unreported

Floor (where tile is

ND)/carpet mastic

Black Non

Friable

Concord

Analysis, 1997 and H2, 2011

Corridor @ W142, W111, Corridor @

W170, W126 Chrysotile Unreported

Floor Tile/Mastic

Brown/Black Non

Friable

Concord

Analysis, 1997 and H2, 2011

W147 (under carpet), Waiting

Area, 2nd Flr Corridor C2-2-2, 1st Flr W161A, Corridor DC-C5, MC-C3

Chrysotile Unreported Floor

Tile/Mastic Red/Black

Non

Friable

Concord

Analysis, 1997 and H2, 2011

Corridor @ W227, Corridor @ W215, , Corridor @

W242, E252A, SE

entry to Kitchen, , Rm 40 (under carpet), Rm 42, 1st

Flr W164, Chrysotile Unreported Floor

Tile/Mastic Beige/Black

Non

Friable

Concord

Analysis, 1997 and H2, 2011

W212, corridor @ W212, #9

Treatment Room, E240, , E229

Chrysotile Unreported Floor

Tile/Mastic Gray/Black

Non

Friable

Concord

Analysis, 1997 and H2, 2011

W227, E229, , R42, R40, Chrysotile Unreported Joint

Compound Beige

Non Friable

H2, 2011 Penthouse, N, NW, S

Chrysotile

<1%

8,000 SF

Exterior Stucco

Unreported Non

Friable

Millennium Consulting Associates 6 Project No. 22015.2033

Data Source Location Asbestos Type

Asbestos Quantity

Material Description Color

Friable

ACBM

H2, 2011

11th Flr Mech Rm 1131, 1132, 7th Flr, 6th Fl, 4th Flr, 3rd

Flr

Chrysotile <1%

100,000 SF

Joint

Compund White

Non Friable

H2, 2011 3rd Flr Rm 312 Chrysotile 100 SF Carpet Mastic Black/Yellow Non

Please refer to Section 3 for details.

Materials Not Sampled per COTR Request:

1. All Doors

2. “Welded” Sheet Vinyl flooring except specifically instructed by COTR.

3. All Electrical Wiring

4. All other materials specifically called out in provided Finish Schedule.

5. Roof.

Millennium Consulting Associates 7 Project No. 22015.2033

2.0 INTRODUCTION

Millennium Consulting Associates (Millennium) performed a Comprehensive Triennial Asbestos Survey for the VA Medical Center in Long Beach, California under Contract No. VA262-14-F-7064. The project was conducted to determine the existence and condition of Asbestos Containing Materials (ACM) in specified buildings. A summary of the survey final results are incorporated into this report providing a means for the VA to more efficiently plan for repairs, renovations and/or demolition projects. In addition, a comprehensive Access database was developed specifically to manage the asbestos and lead data obtained for this project.

2.1 SCOPE OF WORK

The objective of this limited asbestos and lead survey is to provide the following information:

1. Identify, document and sample previously un-sampled suspect ACM;

2. Report, assess, and quantify all ACM discovered during the survey;

3. Provide comprehensive spreadsheet (finish schedule) of asbestos-containing materials identified.

The asbestos survey tasks included a review of previous asbestos surveys, abatement response action records, a thorough walk-thru of accessible areas within each building within the contract to identify accessible suspect asbestos finish/material, collection of representative samples for asbestos, assessment of the condition of the materials and quantification of the asbestos-containing materials throughout the specified buildings.

In accordance with the project requirements, samples were not taken if it rendered the material unstable, had the potential to cause leaking or other deterioration of the base material or if the sampling posed a hazard to those working in and around the building. The sampling of specific materials identified by the client, newly or recently renovated areas was omitted per the direction of the client.

2.2 SAMPLING METHODS, PROCEDURES AND PERSONNEL

A detailed sampling and analysis plan was prepared to facilitate sampling of homogeneous materials for asbestos. These are materials that are similar in appearance and texture, based on the substrate and/or suspect material. The asbestos survey was performed using general procedures and protocols defined in EPA 40 CFR, part 763.

The asbestos analyses were performed at an independent 3rd party accredited laboratory (EMSL Laboratory, San Diego, CA.) using the EPA 600/R-93/116 method. All locations within the scope of work were physically inspected and categorized by homogeneous area, to determine the presence of ACM.

Millennium personnel held valid licenses for the respective type of work they performed. These asbestos specific licenses include: Certified Asbestos Consultants (CAC) and Site-Surveillance Technicians (SST). The project team members and their respective certifications that performed site assessment activities are:

1. Mr. Jack McCubbin (CAC No. 93-0894),

2. Mr. Jeremy Malson, CIH, CSP (CAC No. 07-4183)

3. Ms. Lee Anne Norman (CAC No. 11-4779), and

4. Mr. Todd Reed (CSST No. 06-4032).

Millennium Consulting Associates 8 Project No. 22015.2033

Physical Inspection, material sampling and physical assessment of the materials within Building 126 was conducted in March 2015 by the personnel above.

2.2.1 Review of Procedures: Asbestos Inspection, Bulk Sampling, Laboratory Information and Risk Assessment

The asbestos inspection and bulk sampling procedures were based on the guidelines established by the U.S.

EPA in the Guidance for Controlling Asbestos Containing Materials in Buildings, Office of Pesticides and Toxic Substances, DOC #560/5-85-024 and 40 CFR Part 763, Asbestos Hazard Emergency Response Act (AHERA). Field information was organized according to the AHERA concept of Homogeneous Areas (HA).

A HA is defined as a suspect material of similar age, appearance, function, and texture. Each homogeneous material was grouped together as a specific HA, sampled, and then assessed for condition. The AHERA guidelines represent an industry standard sampling protocol and as such was utilized during the inspection and sampling.

The locations within the buildings were physically inspected on a space-by-space and homogeneous area-by-homogeneous area basis, to determine the presence of ACM. Core samples of friable and non-friable suspect materials were collected by penetration of the suspect material to its substrate where allowed by the client.

The bulk samples collected were placed in individual sealed containers and labeled with unique sample identification numbers. Representative samples of each homogeneous sampling area were then submitted to the laboratory to be analyzed for asbestos content.

Specifically, the inspection involved the following tasks:

1. Visual determination as to the extent of visible and accessible suspect materials and conditions of the material;

2. Collection and analyses of suspect building materials for asbestos content;

3. Determining condition (i.e., friable or non-friable) of suspect materials by physically touching, assessing, and placing the material into the correct ACM category (i.e., Physical Condition Assessment);

4. Quantification of the amount of ACM friable and non-friable materials along with their location;

5. Identification of all suspect materials sampled on the appropriate building floor plan diagram with the sample number; and

6. Preparation of a Chain-of-Custody form that accompanied the samples to the laboratory.

2.2.1.a Sample Chain of Custody and Contract Laboratory:

Chain-of-Custody procedures and records provide a means of tracing each sample from the time of collection through the shipment and final analyses. Proper Chain-of-Custody procedures also provide a written record of all persons handling the samples. The information necessary to relate sample locations for reporting purposes is documented with each sample. This information is essential to proper completion of a sample results report and typically includes client and facility information; unique sample identification number; date and time sampled; sampler name and signature; sample location including the room/area; and field sketches of sample locations.

Millennium Consulting Associates 9 Project No. 22015.2033

All sample analyses were performed by EMSL Laboratory, located in San Diego, CA. EMSL is a laboratory which is certified by the State of California Environmental Laboratory Accreditation Program (2713), the U.S.

Department of Commerce, National Institute of Standards and Technology (NIST) and is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP No. 200855-0) for bulk asbestos analyses.

2.2.1.b Asbestos Material Physical/Condition Assessment:

The U.S. EPA AHERA specifies that a physical assessment of all friable suspect material must be performed during the inspection. The physical condition assessment consists of determining the condition of the ACM, and the potential for future disturbance. AHERA lists seven categories in which to assess the current condition and potential for damage for those asbestos materials having an asbestos content greater than 1%. These are considered Asbestos Containing Materials (ACM). These categories are as follows:

1. Damaged or Significantly Damaged Friable Thermal System Insulation;

2. Damaged Friable Surfacing Material;

3. Significantly Damaged Friable Surfacing Material;

4. Damaged or Significantly Damaged Friable Miscellaneous Material;

5. ACM with potential for damage;

6. ACM with the potential for significant damage; and

7. Any remaining Friable ACM or Assumed Friable ACM.

Additionally, as part of the assessment and categorization of materials, the ACMs are further defined by the current condition of the ACM, and the potential for future damage. These are defined as follows:

1. Current Condition of ACM: Intact, damaged or significantly damaged. The criteria for determining the damaged and significantly damaged conditions are as follows:

a. Damaged: The overall damage is up to ten percent (≤10%) and/or any localized damage is up to twenty-five percent (≤25%).

b. Significantly damaged: The overall damage is greater than ten percent (>10%) and/or any localized damage is greater than (>25%).

2. Potential for Future Damage of ACM: Another step in the assessment process is to determine the potential for future damage or deterioration for material classified as good or fair. The potential for future damage was classified as High, Moderate, or Low for Human Contact, Vibration and Air Erosion.

3. Friability Rating: All material were given a friability rating and classified as either Friable ACM or Non-Friable ACM. Friable ACM is defined as any material that contains more than one percent (>1%) asbestos and can be crumbled, pulverized, or reduced to powder by hand pressure. It is a description of risk and refers to a material’s likeliness to release airborne fibers.

Millennium Consulting Associates 10 Project No. 22015.2033

3.0 BUILDING SUMMARY

BUILDING 126 – MAIN HOSPITAL BUILDING

Building No. 126 is the Main Hospital Building and was built in 1967. The building has one basement and eleven floors and is approximately 300,000 ft2 in size. The structure is concrete, the floors are concrete and the roof is built-up bituminous asphalt. The building is considered to be in good overall condition.

4.0 SURVEY RESULTS

4.1 ACM Data Results

4.1.1 Summary of Previous Sampling Events:

Millennium reviewed twelve (12) documents detailing previous asbestos-related inspections and abatement activities associated with Building 1. The documents include the following:

1. Limited Asbestos Inspection, prepared by H2 Environmental, Project #206901AS, May 2001;

2. Facility Wide Survey, prepared by H2 Environmental, Project #1354510AS, March 2011;

3. Asbestos Abatement event, prepared by H2 Environmental, Project #1390211AM – abatement of

1000 SF of floor tile/mastic at the main corridor, April 2011;

4. Limited Asbestos Inspection, prepared by H2 Environmental, Project #1443011AS, June 2011;

Type

Asbestos Quantity

Material Description Color

Friable

ACBM

Concord Analysis, 1997

Ceiling cavities/mechanical chases throughout

Chrysotile Unreported

Thermal System

Insulation on piping

Beige/white/gray Friable

Concord Analysis, 1997 and H2, 2011

E115, E131, E170, E170, E153, E149, ER Waiting Room, W128, W131, W170, W231V, W231S, E222, E227, E223A, 2nd Flrr Corridor C2-2- 2, Rm 227, , E231, E247, , W231V, !st Fl W102, W105,, E167, , W128F, W128C, W128L, W128

Chrysotile Unreported

Floor (where tile is

ND)/carpet mastic

Black Non

Friable

Concord

Analysis, 1997 and H2, 2011

Corridor @ W142, W111, Corridor @

W170, W126 Chrysotile Unreported

Floor Tile/Mastic

Brown/Black

Millennium Consulting Associates 11 Project No. 22015.2033

Type

Asbestos Quantity

Material Description Color

Friable

ACBM

Concord

Analysis, 1997 and H2, 2011

W147 (under carpet), Waiting

Area, 2nd Flr Corridor C2-2-2, 1st Flr W161A, Corridor DC-C5, MC-C3

Chrysotile Unreported Floor

Tile/Mastic Red/Black

Non

Friable

Concord

Analysis, 1997 and H2, 2011

Corridor @ W227, Corridor @ W215, , Corridor @

W242, E252A, SE

entry to Kitchen, , Rm 40 (under carpet), Rm 42, 1st

Flr W164, Chrysotile Unreported Floor

Tile/Mastic Beige/Black

Non

Friable

Concord

Analysis, 1997 and H2, 2011

W212, corridor @ W212, #9

Treatment Room, E240, , E229

Chrysotile Unreported Floor

Tile/Mastic Gray/Black

Non

Friable

Concord

Analysis, 1997 and H2, 2011

W227, E229, , R42, R40, Chrysotile Unreported Joint

Compound Beige

Non Friable

H2, 2011 Penthouse, N, NW, S

Chrysotile

<1%

8,000 SF

Exterior Stucco

Unreported Non

Friable

H2, 2011

11th Flr Mech Rm 1131, 1132, 7th Flr, 6th Fl, 4th Flr, 3rd

Flr

Chrysotile <1%

100,000 SF

Joint

Compound White

Non Friable

H2, 2011 3rd Flr Rm 312 Chrysotile 100 SF Carpet Mastic Black/Yellow

Millennium Consulting Associates 12 Project No. 22015.2033

4.1.2 FINDINGS OF MILLENNIUM 2014 TRIENNIAL SURVEY & ASSESSMENT

Millennium conducted a site inspection and assessment of Building 126 in March 2015. A total of one hundred fifty two (152) bulk samples were collected within building 126 and then analyzed on a layer-by-layer basis using polarized light microscopy (PLM).

The results of the March, 2015 sampling event are as follows:

Qty.

Asbestos Content / Type

VALB-126-F1.1 ROOM 435 12X12 RESILIENT

FLOOR TILE

SEAFOAM - FLOOR

TILE AQUA N/A ND

VALB-126-F1.1 ROOM 435 12X12 RESILIENT

FLOOR TILE

SEAFOAM - MASTIC YELLOW N/A ND

VALB-126-F1.2 ROOM 126-465 12X12 RESILIENT

FLOOR TILE

SEAFOAM - FLOOR

TILE AQUA N/A ND

VALB-126-F1.2 ROOM 126-465 12X12 RESILIENT

FLOOR TILE

SEAFOAM - MASTIC YELLOW N/A ND

VALB-126-F1.3 ROOM 126-466 12X12 RESILIENT

FLOOR TILE

SEAFOAM AQUA N/A ND

VALB-126-F2.1 ROOM E236 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE WHITE 1

<1 Chrysotile

VALB-126-F2.1 ROOM E236 12X12 RESILIENT

FLOOR TILE -

MASTIC WHITE N/A ND

VALB-126-F3.1 ROOM 1138 1 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE WHITE N/A ND

VALB-126-F3.1 ROOM 1138 12X12 RESILIENT

FLOOR TILE -

MASTIC WHITE N/A ND

VALB-126-F4.1 ROOM CC11-2 12X12 RESILIENT

FLOOR TILE

SEAFOAM - FLOOR

TILE BLUE 1

<1 Chrysotile

VALB-126-F4.1 ROOM CC11-2 12X12 RESILIENT

SEAFOAM - MASTIC BLUE N/A ND

Millennium Consulting Associates 13 Project No. 22015.2033

Qty.

Asbestos Content / Type

VALB-126-F4.2 ROOM W132 12X12 RESILIENT

FLOOR TILE

SEAFOAM - FLOOR

TILE BLUE 1

<1 Chrysotile

VALB-126-F4.2 ROOM W132 12X12 RESILIENT

FLOOR TILE

SEAFOAM - MASTIC BLUE N/A ND

VALB-126-F4.3 ROOM EC-C6 12X12 RESILIENT

FLOOR TILE

SEAFOAM - FLOOR

TILE BLUE 1

<1 Chrysotile

VALB-126-F4.3 ROOM EC-C6 12X12 RESILIENT

FLOOR TILE

SEAFOAM - MASTIC BLUE N/A ND

VALB-126-F5.1 ROOM 632 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE NAVY BLUE 1

<1 Chrysotile

VALB-126-F5.1 ROOM 632 12X12 RESILIENT

FLOOR TILE -

MASTIC NAVY BLUE N/A ND

VALB-126-F6.1 ROOM 1040 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE MAUVE 1

<1 Chrysotile

VALB-126-F6.1 ROOM 1040 12X12 RESILIENT

FLOOR TILE -

MASTIC MAUVE N/A ND

VALB-126-F6.2 ROOM CC-10-8 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE MAUVE 1

<1 Chrysotile

VALB-126-F6.2 ROOM CC-10-8 12X12 RESILIENT

FLOOR TILE - MASTIC MAUVE N/A ND

VALB-126-F6.3 ROOM CC-10-5 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE MAUVE 1

<1 Chrysotile

VALB-126-F6.3 ROOM CC-10-5 12X12 RESILIENT

FLOOR TILE -

MASTIC MAUVE N/A ND

VALB-126-F7.1 ROOM EC-C2 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE RUST 1

2% Chrysotile

VALB-126-F7.1 ROOM EC-C2 12X12 RESILIENT

FLOOR TILE -

MASTIC RUST 1

4% Chrysotile

VALB-126-F8.1 ROOM 356A 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE BROWN 1

2%

Millennium Consulting Associates 14 Project No. 22015.2033

Qty.

Asbestos Content / Type

VALB-126-F8.1 ROOM 356A 12X12 RESILIENT

FLOOR TILE -

MASTIC BROWN N/A ND

VALB-126-F8.2 ROOM W160 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE BROWN 1

2% Chrysotile

VALB-126-F8.2 ROOM W160 12X12 RESILIENT

FLOOR TILE -

MASTIC BROWN N/A ND

VALB-126-F8.3 ROOM W108 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE BROWN 1

2% Chrysotile

VALB-126-F8.3 ROOM W108 12X12 RESILIENT

FLOOR TILE -

MASTIC BROWN 1

4% Chrysotile

VALB-126-F9.1 ROOM C126-6-5 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE BROWN N/A ND

VALB-126-F9.1 ROOM C126-6-5 12X12 RESILIENT

FLOOR TILE -

MASTIC BROWN N/A ND

VALB-126-F10.1 ROOM C2-2-5 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE BROWN N/A ND

VALB-126-F10.1 ROOM C2-2-5 12X12 RESILIENT

FLOOR TILE -

MASTIC BROWN N/A ND

VALB-126-F10.2 ROOM 1044 1 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE BROWN N/A ND

VALB-126-F10.2 ROOM 1044 12X12 RESILIENT

FLOOR TILE -

MASTIC BROWN N/A ND

VALB-126-F10.3 ROOM DC-C3 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE BROWN N/A ND

VALB-126-F10.3 ROOM DC-C3 12X12 RESILIENT

FLOOR TILE -

MASTIC BROWN N/A ND

VALB-126-F11.1 ROOM 1013 12X12 RESILIENT

FLOOR TILE

SEAFOAM - FLOOR

TILE PINK N/A ND

VALB-126-F11.1 ROOM 1013 12X12 RESILIENT

SEAFOAM - MASTIC PINK N/A ND

Millennium Consulting Associates 15 Project No. 22015.2033

Qty.

Asbestos Content / Type

VALB-126-F11.2-

Floor Tile

ROOM C126-458 12X12 RESILIENT

FLOOR TILE

SEAFOAM - FLOOR

TILE PINK N/A ND

VALB-126-F11.2 ROOM C126-458 12X12 RESILIENT

FLOOR TILE

SEAFOAM - MASTIC PINK N/A ND

VALB-126-F11.3 ROOM 440 12X12 RESILIENT

FLOOR TILE

SEAFOAM - FLOOR

TILE PINK N/A ND

VALB-126-F11.3 ROOM 440 12X12 RESILIENT

FLOOR TILE

SEAFOAM - MASTIC PINK N/A ND

VALB-126-F12.1 ROOM 2 FAC 1 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE BROWN N/A ND

VALB-126-F12.1 ROOM 2 FAC 1 12X12 RESILIENT

FLOOR TILE -

MASTIC BROWN N/A ND

VALB-126-F13.1 ROOM 1120 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE OLIVE N/A ND

VALB-126-F13.1 ROOM 1120 E 12X12 RESILIENT

FLOOR TILE -

MASTIC OLIVE N/A ND

VALB-126-F14.1 ROOM W213 12X12 RESILIENT

FLOOR TILE -

MASTIC 1 BLACK N/A ND

VALB-126-F14.1 ROOM W213 12X12 RESILIENT

FLOOR TILE - FLOOR

TILE BLACK 1

2% Chrysotile

VALB-126-F14.1 ROOM W213 12X12 RESILIENT

FLOOR TILE -

MASTIC 2 BLACK 1

6% Chrysotile

VALB-126-F15.1 ROOM 000 16X16 VINYL FLOOR

TILE - VINYL SHEET

FLOORING

MULTI-

COLOR N/A ND

VALB-126-F15.1 ROOM 000 16X16 VINYL FLOOR

TILE - MASTIC

MULTI-

COLOR N/A ND

VALB-126-F15.2 ROOM E201 1 16X16 VINYL FLOOR

TILE - VINYL FLOOR

TILE

MULTI-

COLOR N/A ND

VALB-126-F15.2 ROOM E201 16X16 VINYL FLOOR

TILE - MASTIC

MULTI-

COLOR N/A ND

Millennium Consulting Associates 16 Project No. 22015.2033

Qty.

Asbestos Content / Type

VALB-126-F16.1 ROOM 132A 16X16 VINYL FLOOR

TILE -VINYL FLOOR

TILE BEIGE N/A ND

VALB-126-F16.1 ROOM 132A 16X16 VINYL FLOOR

TILE - MASTIC BEIGE N/A ND

VALB-126-F17.1 ROOM EC-C2 16X16 VINYL FLOOR

TILE TAN N/A ND

VALB-126-F18.1 ROOM CC-200 24X24 VINYL FLOOR

TILE BROWN N/A ND

VALB-126-F19.1 ROOM CC-200 24X24 VINYL FLOOR

TILE BEIGE N/A ND

VALB-126-F20.1 ROOM D260 24X24 VINYL FLOOR

TILE - VINYL FLOOR

TILE GRAY N/A ND

VALB-126-F20.1 ROOM D260 24X24 VINYL FLOOR

TILE - MASTIC GRAY N/A ND

VALB-126-F21.1 ROOM E-C2-2.2 24X24 VINYL FLOOR

TILE LIGHT GRAY N/A ND

VALB-126-F22.1 ROOM CC-200 24X24 VINYL FLOOR

TILE YELLOW N/A ND

VALB-126-F23.1 ROOM D245 24X24 VINYL FLOOR

TILE TAN N/A ND

VALB-126-F24.1 ROOM W201 RESILIENT FLOOR -

SHEET FLOORING WHITE N/A ND

VALB-126-F24.1 ROOM W201 RESILIENT FLOOR

SHEETING - MASTIC WHITE N/A ND

VALB-126-F25.1 ROOM 416 RESILIENT FLOOR

SHEETING - SHEET

FLOORING PINK/BLUE N/A ND

VALB-126-F25.1 ROOM 416 RESILIENT FLOOR

SHEETING - MASTIC PINK/BLUE N/A ND

VALB-126-F26.1 ROOM C5-1C RESILIENT FLOOR

SHEETING - SHEET

FLOORING BLUE N/A ND

VALB-126-F26.1 ROOM C5-1C RESILIENT FLOOR

SHEETING - MASTIC BLUE N/A ND

VALB-126-F26.2 ROOM 532D RESILIENT FLOOR

SHEETING BLUE N/A ND

VALB-126-F27.1 ROOM 509 RESILIENT FLOOR

SHEETING - SHEET

FLOORING

LIGHT

BROWN N/A ND

VALB-126-F27.1 ROOM 509 RESILIENTFLOOR

SHEETING - MASTIC

LIGHT

BROWN N/A ND

VALB-126-F28.1 ROOM E123 RESILIENT FLOOR

SHEETING - VINYL

SHEET FLOORING GRAY N/A ND

Millennium Consulting Associates 17 Project No. 22015.2033

Qty.

Asbestos Content / Type

VALB-126-F28.1 ROOM E123 RESILIENT FLOOR

SHEETING- MASTIC GRAY N/A ND

VALB-126-F29.1 ROOM E155 RESILIENT FLOOR

SHEETING GREEN N/A ND

VALB-126-F30.1 ROOM D223 RESILIENT FLOOR

SHEETING - SHEET

FLOORING GRAY N/A ND

VALB-126-F30.1 ROOM D223 RESILIENT FLOOR

SHEETING - MASTIC GRAY N/A ND

VALB-126-F31.1 ROOM 253 RESILIENT FLOOR

SHEETING - SHEET

FLOORING WHITE N/A ND

VALB-126-F31.1 ROOM 253 RESILIENT FLOOR

SHEETING - MASTIC WHITE N/A ND

VALB-126-F32.1 ROOM D257 RESILIENT FLOOR

SHEETING GRAY N/A ND

VALB-126-F32.2 ROOM D251 RESILIENT FLOOR

SHEETING GRAY N/A ND

VALB-126-F33.1 ROOM E-C2-2.2 RESILIENT FLOOR

SHEETING - SHEET

FLOORING DARK GRAY N/A ND

VALB-126-F33.1 ROOM E-C2-2.2 RESILIENT FLOOR

SHEETING - MASTIC DARK GRAY N/A ND

VALB-126-F34.1 ROOM 519 RESILIENT FLOOR

SHEETING - SHEET

FLOORING GREEN N/A ND

VALB-126-F34.1 ROOM 519 RESILIENT FLOOR

SHEETING - MASTIC GREEN N/A ND

VALB-126-F34.2 ROOM E122 RESILIENT FLOOR

SHEETING GREEN N/A ND

VALB-126-F35.1 ROOM 509 RESILIENT FLOOR

SHEETING BEIGE N/A ND

VALB-126-F35.2 ROOM E122 RESILIENT FLOOR

SHEETING BEIGE N/A ND

VALB-126-F35.3 ROOM 1053 RESILIENT FLOOR

SHEETING - SHEET

FLOORING BEIGE N/A ND

VALB-126-F35.3 ROOM 1053 RESILIENT FLOOR

SHEETING - MASTIC BEIGE N/A ND

VALB-126-F36.1 ROOM E122 RESILIENT FLOOR

SHEETING BROWN N/A ND

VALB-126-F37.1 ROOM 509 RESILIENT FLOOR

SHEETING - SHEET

FLOORING

LIGHT

BROWN N/A ND

VALB-126-F37.1 ROOM 509 RESILIENT FLOOR

SHEETING - MASTIC

LIGHT

BROWN N/A ND

Millennium Consulting Associates 18 Project No. 22015.2033

Qty.

Asbestos Content / Type

VALB-126-F38.1 ROOM 537 RESILIENT FLOOR

SHEETING - SHEET

FLOORING

LIGHT

BROWN N/A ND

VALB-126-F38.1 ROOM 537 RESILIENT FLOOR

SHEETING - MASTIC

LIGHT

BROWN N/A ND

VALB-126-F39.1 ROOM 955 RESILIENT FLOOR

SHEETING - SHEET

FLOORING OLIVE N/A ND

VALB-126-F39.1 ROOM 955 RESILIENT FLOOR

SHEETING - MASTIC OLIVE N/A ND

VALB-126-F39.2 ROOM 932G RESILIENT FLOOR

SHEETING - SHEET

FLOORING OLIVE N/A ND

VALB-126-F39.2 ROOM 932G RESILIENT FLOOR

SHEETING - MASTIC OLIVE N/A ND

VALB-126-F39.3 ROOM 905 RESILIENT FLOOR

SHEETING OLIVE N/A ND

VALB-126-F40.1 ROOM 509 RESILIENT FLOOR

SHEETING - SHEET

FLOORING

LIGHT

BROWN N/A ND

VALB-126-F40.1 ROOM 509N RESILIENT FLOOR

SHEETING - MASTIC

LIGHT

BROWN N/A ND

VALB-126-F41.1 ROOM E226 CARPET GLUE /

UNDER CARPET GRAY N/A ND

VALB-126-F42.1 ROOM E226 CARPET GLUE /

UNDER CARPET BROWN N/A ND

VALB-126-F43.1 ROOM E226 CARPET GLUE /

UNDER CARPET BLUE?BROWN N/A ND

VALB-126-M1.1 ROOM E240 SINK

UNDERCOATING WHITE N/A ND

VALB-126-M2.1 ROOM E205 SINK

UNDERCOATING BLACK N/A ND

VALB-126-M2.2 ROOM E222 SINK

UNDERCOATING BLACK N/A ND

VALB-126-M2.3 ROOM E223 SINK

UNDERCOATING BLACK N/A ND

VALB-126-M3.1 ROOM 926 HVAC SEALANT YELLOW N/A ND

VALB-126-M4.1 ROOM 1131

@126-ST-4 EAST HVAC SEALANT WHITE N/A ND

VALB-126-M5.1 ROOM E103 FIRESTOP - CAULK BLUE N/A ND

VALB-126-M5.1 ROOM E103 FIRESTOP- JOINT

COMPOUND BLUE N/A ND

VALB-126-M5.2 ROOM 1131 FIRESTOP - CAULK BLUE N/A ND

VALB-126-M5.2 ROOM 1131 FIRESTOP - JOINT

COMPOUND BLUE 1

Millennium Consulting Associates 19 Project No. 22015.2033

Qty.

Asbestos Content / Type

VALB-126-M5.3 ROOM C126-6-3 FIRESTOP BLUE N/A ND

VALB-126-M6.1 ROOM MC-C-7 @

W158 FIRESTOP RED N/A ND

VALB-126-M6.2 ROOM 519 FIRESTOP RED N/A ND

VALB-126-M6.3 ROOM CC-9-10 FIRESTOP RED N/A ND

VALB-126-M6.4 ROOM MC-C2 FIRESTOP RED N/A ND

VALB-126-M6.5 ROOM 49 FIRESTOP RED N/A ND

VALB-126-M6.6 ROOM C7-1A FIRESTOP RED N/A ND

VALB-126-M6.7 ROOM C11-1 FIRESTOP RED N/A ND

VALB-126-M7.1 ROOM 000 4" COVEBASE SILVER N/A ND

VALB-126-M8.1 ROOM CC-202 6" COVEBASE - COVE

BASE SILVER N/A ND

VALB-126-M8.1 ROOM CC-202 6" COVEBASE -

MASTIC SILVER N/A ND

VALB-126-M8.2 ROOM D260 6" COVEBASE -

COVE BASE SILVER N/A ND

VALB-126-M8.2 ROOM D260 6" COVEBASE -

MASTIC SILVER N/A ND

VALB-126-M8.3 ROOM E-CC-2.2 6" COVEBASE -

COVE BASE SILVER N/A ND

VALB-126-M8.3 ROOM E-CC-2.2 6" COVEBASE -

JOINT COMPOUND SILVER N/A ND

VALB-126-M9.1 ROOM 359A 6" COVEBASE -

COVE BASE BEIGE N/A ND

VALB-126-M9.1 ROOM 359A 6" COVEBASE -

MASTIC BEIGE N/A ND

VALB-126-M9.1 ROOM 359A 6" COVEBASE -

JOINT COMPOUND BEIGE N/A ND

VALB-126-M10.1 ROOM CC-10-1 4" COVEBASE -

COVE BASE BEIGE N/A ND

VALB-126-M10.1 ROOM CC-10-1 4" COVEBASE -

MASTIC BEIGE N/A ND

VALB-126-M10.2 ROOM 351 4" COVEBASE -

COVE BASE BEIGE N/A ND

VALB-126-M10.2 ROOM 351 4" COVEBASE -

MASTIC BEIGE N/A ND

VALB-126-M10.3 ROOM 438 4" COVEBASE -

COVE BASE BEIGE N/A ND

VALB-126-M10.3 ROOM 438 4" COVEBASE -

MASTIC BEIGE N/A ND

VALB-126-M12.1 ROOM D212 FIREPROOFING TAN N/A ND

VALB-126-M11.1 ROOM C5-1C @

ROOM 503 FIREPROOFING GRAY N/A ND

VALB-126-M11.2 ROOM 517 FIREPROOFING GRAY N/A ND

Millennium Consulting Associates 20 Project No. 22015.2033

Qty.

Asbestos Content / Type

VALB-126-M11.3 ROOM D212 FIREPROOFING GRAY N/A ND

VALB-126-M11.4 ROOM 1131 FIREPROOFING GRAY N/A ND

VALB-126-M11.5 ROOF

PENETRATION

NORTHWEST FIREPROOFING GRAY N/A ND

VALB-126-M11.6 ROOM E-C2-8 FIREPROOFING GRAY N/A ND

VALB-126-M11.7 ROOM 126-C7-2A FIREPROOFING GRAY N/A ND

VALB-126-W1.1 ROOM 101 PLASTER SKIMCOAT WHITE N/A ND

VALB-126-W1.2 ROOM 502 PLASTER SKIMCOAT WHITE N/A ND

VALB-126-W1.3 ROOM 1102 PLASTER SKIMCOAT

- SKIM COAT WHITE N/A ND

VALB-126-W1.3 ROOM 1102 PLASTER SKIMCOAT

- PLASTER TAN N/A ND

VALB-126-W1.4 ROOM C126-B-1 PLASTER SKIMCOAT-

SKIM COAT WHITE N/A ND

VALB-126-W1.4 ROOM C126-B-1 PLASTER SKIMCOAT-

PLASTER TAN N/A ND

VALB-126-W1.5 ROOM 901 PLASTER SKIMCOAT WHITE N/A ND

VALB-126-W1.6 ROOM C5-1C PLASTER SKIMCOAT WHITE N/A ND

VALB-126-W1.7 ROOM C11-6 PLASTER SKIMCOAT

- SKIM COAT WHITE N/A ND

VALB-126-W1.7 ROOM C11-6 PLASTER SKIMCOAT

- PLASTER TAN N/A ND

VALB-126-W2.1 ROOM MC-C3 DRYWALL

SKIMCOAT - SKIM

COAT BEIGE N/A ND

VALB-126-W2.1 ROOM MC-C3 DRYWALL

SKIMCOAT -

DRYWALL WHITE N/A ND

VALB-126-W2.2 ROOM C126-B-4 DRYWALL

SKIMCOAT WHITE N/A ND

VALB-126-W2.3 NO SAMPLE N/A ND

VALB-126-W2.4 ROOM C11-6 DRYWALL

SKIMCOAT WHITE N/A ND

VALB-126-W2.5 ROOM 1013 DRYWALL

SKIMCOAT WHITE N/A ND

VALB-126-W2.6 ROOM C5-1C DRYWALL

SKIMCOAT WHITE N/A ND

VALB-126-W2.7 ROOM C126-471 DRYWALL

SKIMCOAT WHITE N/A ND

VALB-126-C1.1 ROOM 9FAC4 CEILING

WALLBOARD WHITE N/A ND

Millennium Consulting Associates 21 Project No. 22015.2033

Qty.

Asbestos Content / Type

VALB-126-C1.1 ROOM 9FAC4 CEILING - JOINT

COMPOUND BEIGE 1

<1 Chrysotile

VALB-126-C1.2 ROOM 11TH

FLOOR ELEC

CEILING

WALLBOARD WHITE N/A ND

VALB-126-C1.2 ROOM 11TH

FLOOR ELEC

CEILING - JOINT

COMPOUND WHITE 1

2% Chrysotile

VALB-126-C1.3 ROOM 1FAC2 CEILING

WALLBOARD WHITE N/A ND

VALB-126-C1.3 ROOM 1FAC2 CEILING - JOINT

COMPOUND WHITE N/A ND

VALB-126-C1.4 ROOM 5TH

FLOOR ELEC

CEILING

WALLBOARD WHITE N/A ND

VALB-126-C1.4 ROOM 5TH

FLOOR ELEC

CEILING - JOINT

COMPOUND WHITE N/A ND

VALB-126-C1.5 ROOM W146 CEILING

WALLBOARD WHITE N/A ND

VALB-126-C1.5 ROOM W146 CEILING - JOINT

COMPOUND WHITE N/A ND

VALB-126-C1.6 ROOM 10FAC1 CEILING -

WALLBOARD WHITE N/A ND

VALB-126-C1. ROOM 10FAC1 CEILING - JOINT

COMPOUND WHITE 1

<1 Chrysotile

VALB-126-C1.7 ROOM 33 CEILING JOINT

COMPOUND WHITE N/A ND

VALB-126-C1.7 ROOM 33 CEILING

WALLBOARD WHITE N/A ND

VALB-126-C2.1 ROOM 17 CEILING PLASTER -

FINISH COAT WHITE N/A ND

VALB-126-C2.1 ROOM 17 CEILING PLASTER -

BASE COAT BEIGE N/A ND

VALB-126-C2.2 ROOM 15B CEILING PLASTER -

FINISH COAT WHITE N/A ND

VALB-126-C2.2 ROOM 15B CEILING PLASTER -

BASE COAT BEIGE N/A ND

VALB-126-C2.3 ROOM 509 CEILING PLASTER?? GRAY N/A ND

VALB-126-C3.1 ROOM B15 2X4 ACOUSTIC

CEILING TILE NO

HOLE SOLID

DRYWALL PINK N/A ND

VALB-126-C4.1 ROOM E170 2X2X12X12

ACOUSTIC CEILING

TILE PINHOLE WHITE N/A ND

VALB-126-C5.1 ROOM W164 2X4 ACOUSTIC

CEILING TILE BIG

PINHOLE WHITE N/A ND

Millennium Consulting Associates 22 Project No. 22015.2033

Qty.

Asbestos Content / Type

VALB-126-C6.1 ROOM W164 2X4 ACOUSTIC

CEILING TILE

PINHOLE CIRCULAR WHITE N/A ND

VALB-126-C7.1 ROOM 351 2X4 ACOUSTIC

CEILING TILE

LARGE PINHOLE

CIRCULAR WHITE N/A ND

VALB-126-C8.1 ROOM MC-C3 2X2 ACOUSTIC

CEILING TILE NO

HOLE WHITE N/A ND

VALB-126-C9.1 ROOM 718 2X4 ACOUSTIC

CEILING TILE NO

HOLE WHITE N/A ND

VALB-126-C9.2 ROOM D245 2X4 ACOUSTIC

CEILING TILE NO

HOLE WHITE N/A ND

VALB-126-C10.1 ROOM W151 2X4 ACOUSTIC

CEILING TILE

PINHOLE BIG WORM WHITE N/A ND

VALB-126-C11.1 ROOM W169 2X4 ACOUSTIC

CEILING TILE

PINHOLE WHITE N/A ND

VALB-126-C12.1 ROOM 112 2X4 ACOUSTIC

CEILING TILE

PINHOLE WORM WHITE N/A ND

VALB-126-C13.1 ROOM C5-C1@

ROOM 505

2X4 ACOUSTIC

CEILING TILE NO

HOLE ROUGH WHITE N/A ND

VALB-126-C14.1 ROOM B40 2X2 ACOUSTIC

CEILING TILE NO

HOLE ROUGH WHITE N/A ND

VALB-126-C15.1 ROOM B40 2X4X2 ACOUSTIC

CEILING TILE NO

HOLE ROUGH WHITE N/A ND

VALB-126-C16.1 ROOM 112 2X2 ACOUSTIC

CEILING TILE

PINHOLE WORM WHITE N/A ND

VALB-126-M13.1 ROOM 625 HVAC SEALANT GRAY N/A ND

VALB-126-F44.1 ROOM D213 RESILIENT FLOOR

SHEETING WHITE N/A ND

VALB-126-R1.1 11TH FLOOR

ROOF

SOUTHWEST

BUILT UP ROOF

GRAVEL BLACK N/A ND

Millennium Consulting Associates 23 Project No. 22015.2033

Qty.

Asbestos Content / Type

VALB-126-R1.2 11TH FLOOR

ROOF

PENTHOUSE

CENTER

BUILT UP ROOF

GRAVEL BLACK N/A ND

VALB-126-R1.3 11TH FLOOR

ROOF NORTH

BUILT UP ROOF

GRAVEL BLACK N/A ND

VALB-126-R2.1 11TH FLOOR

ROOF

PENTHOUSE

CENTER ROOF FLASHING BLACK N/A ND

VALB-126-R2.2 11TH FLOOR

ROOF

NORTHWEST ROOF FLASHING BLACK N/A ND

VALB-126-R3.1 11TH FLOOR

ROOF

PENETRATION

HOUSE CENTER

PENETRATION

MASTIC BLACK 1

2% Chrysotile

VALB-126-R3.2 11TH FLOOR

ROOF SOUTH

HVAC SUPPORT

PENETRATION BLACK N/A ND

VALB-126-R3.3 11TH FLOOR

ROOF

SOUTHWEST

PENETRATION

MASTIC BLACK N/A ND

VALB-126-R4.1 11TH FLOOR

ROOF EAST

HVAC SEALANT

GRAY - SEALANT 1 GRAY N/A ND

VALB-126-R4.1 11TH FLOOR

ROOF EAST

HVAC SEALANT

GRAY - SEALANT 2 TAN N/A ND

VALB-126-R4.2 2ND FLOOR

ROOF WEST

HVAC SEALANT

GRAY BLACK N/A ND

VALB-126-R5.1 2ND FLOOR

ROOF EAST

ROOF FLASHING

GRAY BLACK N/A ND

VALB-126-R5.2 2ND FLOOR

ROOF SOUTH

ROOF FLASHING

GRAY BLACK N/A ND

VALB-126-R5.3 2ND FLOOR

ROOF

NORTHWEST ROOF FLASHING BLACK N/A ND

VALB-126-R6.1 2ND FLOOR

ROOF WEST

PENETRATION

MASTIC

BLACK/GRAY BLACK 1

<1 Chrysotile

VALB-126-R6.2 2ND FLOOR

ROOF EAST

PENETRATION

MASTIC

BLACK/GRAY BLACK N/A ND

VALB-126-R6.3 2ND FLOOR

ROOF

SOUTHWEST

PENETRATION

MASTIC BLACK BLACK N/A ND

Millennium Consulting Associates 24 Project No. 22015.2033

5.0 CONCLUSIONS AND RECOMMENDATIONS

CONCLUSIONS

Based on this survey and a review of previous surveys, the following materials are present within Building 126 which contain asbestos:

Building 126:

Wallboard/joint compound systems: wallboard has consistently been reported as “ND”; joint compound has routinely been reported between <1% to 2% asbestos;

9” floor tile/mastic – reported at 2nd floor;

Floor tile mastic – under 12” beige w/ brown non ACM floor tile at: R218a, 2nd floor corridor, 1st floor Rm W128, MC-CS;

Floor tile mastic – under 12” off white w/ gray streak non ACM floor tile at: E231, E231a, E247;

Floor tile mastic – under 12” cream w/ gray streak non ACM floor tile at: Room W231v;

Floor tile mastic – under 12” cream w/ brown streak non ACM floor tile at: 2nd floor patient corridor C2-2, 1st floor room W102;

Floor tile mastic – under 12” blue/tan non ACM floor tile at: Room W128F, W128C, W128L;

Floor tile mastic – under 12” carpet non ACM floor tile at:E131, E170, E153,E149, W111, W131, W170, W218A, W231V, E222, E227, ER Waiting Room, W126, W227, W215, W262, 43, W128, W212, #9 treatment room, E240, E229, W142, W111, W170;

Gray/black floor insulation at W103

Note: Asbestos-Containing thermal insulation is anticipated to exist in concealed or otherwise limited access areas throughout.

Please refer to the Asbestos Laboratory Data in Appendix A in Appendix B for the complete Finish Schedule.

6.0 LIMITING CONDITIONS

Millennium Consulting conducted the survey in March 2015, in accordance with industry standards in existence at the time of the project. The conclusions and recommendations presented in this report are based on the applicable standards of our profession at the time this report was prepared. Copies of this report are furnished to provide factual data that were gathered and summarized in the report.

The data, analysis and recommendations submitted in this report are solely for use of the Client. It may not be relied upon for third party use. This report has been prepared for the exclusive use of the Client for specific application to the survey performed on the property; this Report is not a construction document and is not intended to replace a NESHAP’s pre-renovation assessment and investigation. Destructive investigation methods were part of this scope of work. This report may not be copied (except by our client) without the written permission of the Client. No other representation, expressed or implied, is made.

Millennium Consulting Associates 25 Project No. 22015.2033

Millennium appreciated having the opportunity to provide you with our asbestos-related services. Should you have any questions regarding this report or require assistance in the design, specification, management, and/or clearance testing for any future repairs, renovations and/or demolition projects, please do not hesitate to contact us.

Appendix A

Asbestos Laboratory Data

EMSL Analytical, Inc.

7916 Convoy Court,Building 4, Suite A, San Diego, CA 92111

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.EMSL.com sandiegolab@emsl.com

431500652

CustomerID: MECA62

CustomerPO: 9491

ProjectID:

EMSL Order:

Attn: Jack McCubbin

Millennium Consulting Associates, Inc.

620 Contra Costa Blvd.

Suite 102

Pleasant Hill, CA 94523

Received: 03/05/15 11:12 AM

VALB ASB SURVEY BUILDING 126/22015.2033

Fax: (925) 808-6708

Phone: (925) 808-6700

Project:

3/12/2015Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using

Polarized Light Microscopy

VALB-126-F1.1-

Floor Tile

431500652-0001

BLDG 126 RM

435 12X12

RESILIENT

FLOOR TILE

SEAFOAM

Blue None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F1.1-

Mastic

431500652-0001A

BLDG 126 RM

435 12X12

RESILIENT

FLOOR TILE

SEAFOAM

Yellow None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F1.2-

Floor Tile

431500652-0002

BLDG 126 RM

126-465 12X12

RESILIENT

FLOOR TILE SEA

Blue None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F1.2-

Mastic

431500652-0002A

BLDG 126 RM

126-465 12X12

RESILIENT

FLOOR TILE SEA

Yellow None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F1.3

431500652-0003

BLDG 126 RM

126-466 12X12

RESILIENT

FLOOR TILE SEA

Blue None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F2.1-

Floor Tile

431500652-0004

BLDG 126 RM

E236 12X12

RESILIENT

FLOOR TILE

WHITE

Gray

Non-Fibrous

Homogeneous

Chrysotile<1%Non-fibrous (other)100%

1Test Report PLM-7.28.9 Printed: 3/12/2015 12:21:24 PM

Derrick Tanner, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%

Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713

Initial report from 03/12/2015 12:21:24

Mariah Barfield (93) Natalia Toscano (89)

Shayne Boney (39) http://www.EMSL.com mailto:sandiegolab@emsl.com

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.EMSL.com sandiegolab@emsl.com

431500652

CustomerID: MECA62

CustomerPO: 9491

ProjectID:

EMSL Order:

Attn: Jack McCubbin

Millennium Consulting Associates, Inc.

620 Contra Costa Blvd.

Suite 102

Pleasant Hill, CA 94523

Received: 03/05/15 11:12 AM

VALB ASB SURVEY BUILDING 126/22015.2033

Fax: (925) 808-6708

Phone: (925) 808-6700

Project:

3/12/2015Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using

Polarized Light Microscopy

VALB-126-F2.1-

Mastic

431500652-0004A

BLDG 126 RM

E236 12X12

RESILIENT

FLOOR TILE

WHITE

Yellow None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F3.1-

Floor Tile

431500652-0005

BLDG 126 RM

1138 12X12

RESILIENT

FLOOR TILE

WHITE

White None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F3.1-

Mastic

431500652-0005A

BLDG 126 RM

1138 12X12

RESILIENT

FLOOR TILE

WHITE

Yellow None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F4.1-

Floor Tile

431500652-0006

BLDG 126 RM

CC11-2 12X12

RESILIENT

FLOOR TILE

SEAF

Blue

Non-Fibrous

Homogeneous

Chrysotile<1%Non-fibrous (other)100%

VALB-126-F4.1-

Mastic

431500652-0006A

BLDG 126 RM

CC11-2 12X12

RESILIENT

FLOOR TILE

SEAF

Yellow None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F4.2-

Floor Tile

431500652-0007

BLDG 126 RM

W132 12X12

RESILIENT

FLOOR TILE

SEAFOA

Blue

Non-Fibrous

Homogeneous

Chrysotile<1%Non-fibrous (other)100%

2Test Report PLM-7.28.9 Printed: 3/12/2015 12:21:24 PM

Derrick Tanner, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%

Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713

Initial report from 03/12/2015 12:21:24

Mariah Barfield (93) Natalia Toscano (89)

Shayne Boney (39)

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.EMSL.com sandiegolab@emsl.com

431500652

CustomerID: MECA62

CustomerPO: 9491

ProjectID:

EMSL Order:

Attn: Jack McCubbin

Millennium Consulting Associates, Inc.

620 Contra Costa Blvd.

Suite 102

Pleasant Hill, CA 94523

Received: 03/05/15 11:12 AM

VALB ASB SURVEY BUILDING 126/22015.2033

Fax: (925) 808-6708

Phone: (925) 808-6700

Project:

3/12/2015Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using

Polarized Light Microscopy

VALB-126-F4.2-

Mastic

431500652-0007A

BLDG 126 RM

W132 12X12

RESILIENT

FLOOR TILE

SEAFOA

Yellow None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F4.3-

Floor Tile

431500652-0008

BLDG 126 RM EC-

C6 12X12

RESILIENT

FLOOR TILE

SEAFO

Blue

Non-Fibrous

Homogeneous

Chrysotile<1%Non-fibrous (other)100%

VALB-126-F4.3-

Mastic

431500652-0008A

BLDG 126 RM EC-

C6 12X12

RESILIENT

FLOOR TILE

SEAFO

Yellow None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F5.1-

Floor Tile

431500652-0009

BLDG 126 RM

632 12X12

RESILIENT

FLOOR TILE

NAVY

Blue

Non-Fibrous

Homogeneous

Chrysotile<1%Non-fibrous (other)100%

VALB-126-F5.1-

Mastic

431500652-0009A

BLDG 126 RM

632 12X12

RESILIENT

FLOOR TILE

NAVY

Yellow None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F6.1-

Floor Tile

431500652-0010

BLDG 126 RM

1040 12X12

RESILIENT

FLOOR TILE

MAUVE

Pink

Non-Fibrous

Homogeneous

Chrysotile<1%Non-fibrous (other)100%

3Test Report PLM-7.28.9 Printed: 3/12/2015 12:21:24 PM

Derrick Tanner, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%

Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713

Initial report from 03/12/2015 12:21:24

Mariah Barfield (93) Natalia Toscano (89)

Shayne Boney (39)

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.EMSL.com sandiegolab@emsl.com

431500652

CustomerID: MECA62

CustomerPO: 9491

ProjectID:

EMSL Order:

Attn: Jack McCubbin

Millennium Consulting Associates, Inc.

620 Contra Costa Blvd.

Suite 102

Pleasant Hill, CA 94523

Received: 03/05/15 11:12 AM

VALB ASB SURVEY BUILDING 126/22015.2033

Fax: (925) 808-6708

Phone: (925) 808-6700

Project:

3/12/2015Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using

Polarized Light Microscopy

VALB-126-F6.1-

Mastic

431500652-0010A

BLDG 126 RM

1040 12X12

RESILIENT

FLOOR TILE

MAUVE

Yellow None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F6.2-

Floor Tile

431500652-0011

BLDG 126 RM CC-

10-8 12X12

RESILIENT

FLOOR TILE MAU

Pink

Non-Fibrous

Homogeneous

Chrysotile<1%Non-fibrous (other)100%

VALB-126-F6.2-

Mastic

431500652-0011A

BLDG 126 RM CC-

10-8 12X12

RESILIENT

FLOOR TILE MAU

Yellow None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F6.3-

Floor Tile

431500652-0012

BLDG 126 RM CC-

10-5 12X12

RESILIENT

FLOOR TILE MAU

Pink

Non-Fibrous

Homogeneous

Chrysotile<1%Non-fibrous (other)100%

VALB-126-F6.3-

Mastic

431500652-0012A

BLDG 126 RM CC-

10-5 12X12

RESILIENT

FLOOR TILE MAU

Yellow None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F7.1-

Floor Tile

431500652-0013

BLDG 126 RM EC-

C2 12X12

RESILIENT

FLOOR TILE

RUST

Rust

Non-Fibrous

Homogeneous

Chrysotile2%Non-fibrous (other)98%

4Test Report PLM-7.28.9 Printed: 3/12/2015 12:21:24 PM

Derrick Tanner, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%

Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713

Initial report from 03/12/2015 12:21:24

Mariah Barfield (93) Natalia Toscano (89)

Shayne Boney (39)

Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.EMSL.com sandiegolab@emsl.com

431500652

CustomerID: MECA62

CustomerPO: 9491

ProjectID:

EMSL Order:

Attn: Jack McCubbin

Millennium Consulting Associates, Inc.

620 Contra Costa Blvd.

Suite 102

Pleasant Hill, CA 94523

Received: 03/05/15 11:12 AM

VALB ASB SURVEY BUILDING 126/22015.2033

Fax: (925) 808-6708

Phone: (925) 808-6700

Project:

3/12/2015Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using

Polarized Light Microscopy

VALB-126-F7.1-

Mastic

431500652-0013A

BLDG 126 RM EC-

C2 12X12

RESILIENT

FLOOR TILE

RUST

Black

Non-Fibrous

Homogeneous

Chrysotile4%Non-fibrous (other)96%

VALB-126-F8.1-

Floor Tile

431500652-0014

BLDG 126 RM

356A 12X12

RESILIENT

FLOOR TILE

BEIGE

Beige

Non-Fibrous

Homogeneous

Chrysotile2%Non-fibrous (other)98%

VALB-126-F8.1-

Mastic

431500652-0014A

BLDG 126 RM

356A 12X12

RESILIENT

FLOOR TILE

BEIGE

Yellow None Detected

Non-Fibrous

Homogeneous

Non-fibrous (other)100%

VALB-126-F8.2-

Floor Tile

431500652-0015

BLDG 126 RM

W160 12X12

RESILIENT

FLOOR TILE

BEIGE

Beige

Non-Fibrous

Homogeneous

Chrysotile2%Non-fibrous…