BUILDING-126.pdf
PDF 10 MB Posted
- Attached to
- Site-Wide HVAC Compliance Upgrade for RME
- Solicitation number
- 36C26224B0009
About this file
This federal contract opportunity is for a site-wide HVAC compliance upgrade for reusable medical equipment at Department of Veterans Affairs facilities. The solicitation seeks proposals to upgrade heating, ventilation, and air conditioning systems to meet compliance standards at multiple locations under Veterans Integrated Service Network 22. Offerors should respond to solicitation number 36C26224B0009 by the unspecified deadline to provide replacement HVAC equipment, installation services, and compliance verification for reusable medical device processing areas. The Veterans Health Administration aims to address HVAC deficiencies through this opportunity in order to properly sanitize reusable medical equipment for veteran patients.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BUILDING-161.pdf | ||
| BUILDING-1.pdf | ||
| BUILDING-2.pdf | ||
| BUILDING-7.pdf | ||
| 36C26224B0009 0001.pdf | ||
| RFIs Final.docx | DOCX document | |
| P01 Drawings 600-17-118.pdf | ||
| P07 WRD.pdf | ||
| P01 Specifications 600-17-118.pdf | ||
| S02 Solicitation 36C26224B0009.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TRIENNIAL ASBESTOS REINSPECTION REPORT
BUILDING 126 – MAIN HOSPITAL BUILDING
PREPARED FOR
Mr. James Bachman & Ms. Olivia Parducho
Department of Veterans Affairs VA Long Beach Healthcare System
5901 East 7th St.
Long Beach CA 90815
Contract Number: GS-10F-0229U - Order Number: VA262-14-F-7064
PREPARED BY
Millennium Consulting Associates 620 Contra Costa Boulevard, Suite 102
Pleasant Hill, CA 94523
May 15, 2015 Millennium Project No. 22015.2033
Millennium Consulting Associates 2 Project No. 22015.2033
Table of Contents
1.0 EXECUTIVE SUMMARY
2.0 INTRODUCTION
2.1 SCOPE OF WORK
2.2 SAMPLING METHODS, PROCEDURES AND PERSONNEL
2.2.1 Review of Procedures: Asbestos Inspection, Bulk Sampling, Laboratory Information and Risk Assessment
3.0 BUILDING SUMMARY
4.0 SURVEY RESULTS
4.1.1 Summary of Previous Sampling Events
4.1.2 FINDINGS OF MILLENNIUM 2014 TRIENNIAL SURVEY & ASSESSMENT
5.0 CONCLUSIONS AND RECOMMENDATIONS
6.0 LIMITING CONDITIONS
Appendices Asbestos Laboratory Sample Data ............................................................................................................... Appendix A
Asbestos Finish schedule & Hazard Assessment ...................................................................................... Appendix B
Sample Location Maps .................................................................................................................................... Appendix C
Millennium Consulting Associates 3 Project No. 22015.2033
1.0 EXECUTIVE SUMMARY
Millennium Consulting Associates (Millennium) performed comprehensive triennial asbestos survey for the VA Medical Center in Long Beach, California under Contract No. VA262-14-F-7064. The objective of this project is to support the Operations & Maintenance Program be conducting the following tasks:
Review VA-supplied previous Asbestos Survey, Assessment and abatement records;
Conduct a comprehensive site evaluation of accessible locations within each specified building to, identify, assess & evaluate condition(s) and collect representative bulk samples of previously un-sampled or newly observed PACM, suspect ACCM, and suspect ACM;
Provide an asbestos health risk assessment and determine location and quantity estimates of ACCM and ACM.
A summary of the survey final results are incorporated into this report, providing a means for the VA to more efficiently plan for repairs, renovations and/or demolition projects.
Table 1, below, summarizes the positive Asbestos survey results from this project for Building 126 – Main Hospital Building.
This is only a list of sample locations. See attached Finish Schedule for all locations of all materials.
Table 1. Survey Summary of Positive Asbestos ACM Results reported by Millennium for Building 126.
Sample No. Sample Location Material Type Color Approx.
Qty.
Asbestos Content / Type
VALB-126-F2.1 ROOM E236 12X12 RESILIENT
FLOOR TILE WHITE 1
<1 Chrysotile
VALB-126-F4.1 ROOM CC11-2 12X12 RESILIENT
FLOOR TILE
SEAFOAM BLUE 1
<1 Chrysotile
VALB-126-F4.2 ROOM W132 12X12 RESILIENT
FLOOR TILE
SEAFOAM BLUE 1
<1 Chrysotile
VALB-126-F4.3 ROOM EC-C6 12X12 RESILIENT
FLOOR TILE
SEAFOAM BLUE 1
<1 Chrysotile
VALB-126-F5.1 ROOM 632 12X12 RESILIENT
FLOOR TILE NAVY BLUE 1
<1 Chrysotile
VALB-126-F6.1 ROOM 1040 12X12 RESILIENT
FLOOR TILE MAUVE 1
<1 Chrysotile
VALB-126-F6.2 ROOM CC-10-8 12X12 RESILIENT
FLOOR TILE MAUVE 1
<1 Chrysotile
VALB-126-F6.3 ROOM CC-10-5 12X12 RESILIENT
FLOOR TILE MAUVE 1
<1 Chrysotile
Millennium Consulting Associates 4 Project No. 22015.2033
Sample No. Sample Location Material Type Color Approx.
Qty.
Asbestos Content / Type
VALB-126-F7.1 ROOM EC-C2 12X12 RESILIENT
FLOOR TILE RUST 1
2% Chrysotile
VALB-126-F7.1 ROOM EC-C2 12X12 RESILIENT
FLOOR TILE
MASTIC RUST 1
4% Chrysotile
VALB-126-F8.1 ROOM 356A 12X12 RESILIENT
FLOOR TILE BROWN 1
2% Chrysotile
VALB-126-F8.2 ROOM W160 12X12 RESILIENT
FLOOR TILE BROWN 1
2% Chrysotile
VALB-126-F8.3 ROOM W108 12X12 RESILIENT
FLOOR TILE BROWN 1
2% Chrysotile
VALB-126-F8.3 ROOM W108 12X12 RESILIENT
FLOOR TILE
MASTIC BROWN 1
4% Chrysotile
VALB-126-F14.1 ROOM W213 12X12 RESILIENT
FLOOR TILE BLACK 1
2% Chrysotile
VALB-126-F14.1 ROOM W213 12X12 RESILIENT
FLOOR TILE
MASTIC 2 BLACK 1
6% Chrysotile
VALB-126-M5.2 ROOM 1131 FIRESTOP - JOINT
COMPOUND BLUE 1
<1 Chrysotile
VALB-126-C1.1 ROOM 9FAC4 CEILING
WALLBOARD
JOINT
COMPOUND - BEIGE 1
<1 Chrysotile
VALB-126-C1.2 ROOM 11TH
FLOOR ELEC
CEILING
WALLBOARD
JOINT
COMPOUND WHITE 1
2% Chrysotile
VALB-126-C1. ROOM 10FAC1 CEILING
WALLBOARD
JOINT
COMPOUND WHITE 1
<1 Chrysotile
VALB-126-R3.1 11TH FLOOR
ROOF
PENETRATION
CENTER
PENETRATION
MASTIC BLACK 1
2% Chrysotile
VALB-126-R6.1 2ND FLOOR
ROOF WEST
PENETRATION
MASTIC
BLACK/GRAY BLACK 1
Millennium Consulting Associates 5 Project No. 22015.2033
Table 2. Summary of Previously Reported Asbestos Containing Materials for Building 126 as reported by others. The presence of ACM materials noted in this table is NOT indicative of the current presence as many of these components have been abated. Please refer to Appendix B.
Data Source Location Asbestos Type
Asbestos Quantity
Material Description Color
Friable
ACBM
Concord Analysis, 1997
Ceiling cavities/mechanical chases throughout
Chrysotile Unreported
Thermal System
Insulation on piping
Beige/white/gray Friable
Concord Analysis, 1997 and H2, 2011
E115, E131, E170, E170, E153, E149, ER Waiting Room, W128, W131, W170, W231V, W231S, E222, E227, E223A, 2nd Flrr Corridor C2-2- 2, Rm 227, , E231, E247, , W231V, !st Fl W102, W105,, E167, , W128F, W128C, W128L, W128
Chrysotile Unreported
Floor (where tile is
ND)/carpet mastic
Black Non
Friable
Concord
Analysis, 1997 and H2, 2011
Corridor @ W142, W111, Corridor @
W170, W126 Chrysotile Unreported
Floor Tile/Mastic
Brown/Black Non
Friable
Concord
Analysis, 1997 and H2, 2011
W147 (under carpet), Waiting
Area, 2nd Flr Corridor C2-2-2, 1st Flr W161A, Corridor DC-C5, MC-C3
Chrysotile Unreported Floor
Tile/Mastic Red/Black
Non
Friable
Concord
Analysis, 1997 and H2, 2011
Corridor @ W227, Corridor @ W215, , Corridor @
W242, E252A, SE
entry to Kitchen, , Rm 40 (under carpet), Rm 42, 1st
Flr W164, Chrysotile Unreported Floor
Tile/Mastic Beige/Black
Non
Friable
Concord
Analysis, 1997 and H2, 2011
W212, corridor @ W212, #9
Treatment Room, E240, , E229
Chrysotile Unreported Floor
Tile/Mastic Gray/Black
Non
Friable
Concord
Analysis, 1997 and H2, 2011
W227, E229, , R42, R40, Chrysotile Unreported Joint
Compound Beige
Non Friable
H2, 2011 Penthouse, N, NW, S
Chrysotile
<1%
8,000 SF
Exterior Stucco
Unreported Non
Friable
Millennium Consulting Associates 6 Project No. 22015.2033
Data Source Location Asbestos Type
Asbestos Quantity
Material Description Color
Friable
ACBM
H2, 2011
11th Flr Mech Rm 1131, 1132, 7th Flr, 6th Fl, 4th Flr, 3rd
Flr
Chrysotile <1%
100,000 SF
Joint
Compund White
Non Friable
H2, 2011 3rd Flr Rm 312 Chrysotile 100 SF Carpet Mastic Black/Yellow Non
Please refer to Section 3 for details.
Materials Not Sampled per COTR Request:
1. All Doors
2. “Welded” Sheet Vinyl flooring except specifically instructed by COTR.
3. All Electrical Wiring
4. All other materials specifically called out in provided Finish Schedule.
5. Roof.
Millennium Consulting Associates 7 Project No. 22015.2033
2.0 INTRODUCTION
Millennium Consulting Associates (Millennium) performed a Comprehensive Triennial Asbestos Survey for the VA Medical Center in Long Beach, California under Contract No. VA262-14-F-7064. The project was conducted to determine the existence and condition of Asbestos Containing Materials (ACM) in specified buildings. A summary of the survey final results are incorporated into this report providing a means for the VA to more efficiently plan for repairs, renovations and/or demolition projects. In addition, a comprehensive Access database was developed specifically to manage the asbestos and lead data obtained for this project.
2.1 SCOPE OF WORK
The objective of this limited asbestos and lead survey is to provide the following information:
1. Identify, document and sample previously un-sampled suspect ACM;
2. Report, assess, and quantify all ACM discovered during the survey;
3. Provide comprehensive spreadsheet (finish schedule) of asbestos-containing materials identified.
The asbestos survey tasks included a review of previous asbestos surveys, abatement response action records, a thorough walk-thru of accessible areas within each building within the contract to identify accessible suspect asbestos finish/material, collection of representative samples for asbestos, assessment of the condition of the materials and quantification of the asbestos-containing materials throughout the specified buildings.
In accordance with the project requirements, samples were not taken if it rendered the material unstable, had the potential to cause leaking or other deterioration of the base material or if the sampling posed a hazard to those working in and around the building. The sampling of specific materials identified by the client, newly or recently renovated areas was omitted per the direction of the client.
2.2 SAMPLING METHODS, PROCEDURES AND PERSONNEL
A detailed sampling and analysis plan was prepared to facilitate sampling of homogeneous materials for asbestos. These are materials that are similar in appearance and texture, based on the substrate and/or suspect material. The asbestos survey was performed using general procedures and protocols defined in EPA 40 CFR, part 763.
The asbestos analyses were performed at an independent 3rd party accredited laboratory (EMSL Laboratory, San Diego, CA.) using the EPA 600/R-93/116 method. All locations within the scope of work were physically inspected and categorized by homogeneous area, to determine the presence of ACM.
Millennium personnel held valid licenses for the respective type of work they performed. These asbestos specific licenses include: Certified Asbestos Consultants (CAC) and Site-Surveillance Technicians (SST). The project team members and their respective certifications that performed site assessment activities are:
1. Mr. Jack McCubbin (CAC No. 93-0894),
2. Mr. Jeremy Malson, CIH, CSP (CAC No. 07-4183)
3. Ms. Lee Anne Norman (CAC No. 11-4779), and
4. Mr. Todd Reed (CSST No. 06-4032).
Millennium Consulting Associates 8 Project No. 22015.2033
Physical Inspection, material sampling and physical assessment of the materials within Building 126 was conducted in March 2015 by the personnel above.
2.2.1 Review of Procedures: Asbestos Inspection, Bulk Sampling, Laboratory Information and Risk Assessment
The asbestos inspection and bulk sampling procedures were based on the guidelines established by the U.S.
EPA in the Guidance for Controlling Asbestos Containing Materials in Buildings, Office of Pesticides and Toxic Substances, DOC #560/5-85-024 and 40 CFR Part 763, Asbestos Hazard Emergency Response Act (AHERA). Field information was organized according to the AHERA concept of Homogeneous Areas (HA).
A HA is defined as a suspect material of similar age, appearance, function, and texture. Each homogeneous material was grouped together as a specific HA, sampled, and then assessed for condition. The AHERA guidelines represent an industry standard sampling protocol and as such was utilized during the inspection and sampling.
The locations within the buildings were physically inspected on a space-by-space and homogeneous area-by-homogeneous area basis, to determine the presence of ACM. Core samples of friable and non-friable suspect materials were collected by penetration of the suspect material to its substrate where allowed by the client.
The bulk samples collected were placed in individual sealed containers and labeled with unique sample identification numbers. Representative samples of each homogeneous sampling area were then submitted to the laboratory to be analyzed for asbestos content.
Specifically, the inspection involved the following tasks:
1. Visual determination as to the extent of visible and accessible suspect materials and conditions of the material;
2. Collection and analyses of suspect building materials for asbestos content;
3. Determining condition (i.e., friable or non-friable) of suspect materials by physically touching, assessing, and placing the material into the correct ACM category (i.e., Physical Condition Assessment);
4. Quantification of the amount of ACM friable and non-friable materials along with their location;
5. Identification of all suspect materials sampled on the appropriate building floor plan diagram with the sample number; and
6. Preparation of a Chain-of-Custody form that accompanied the samples to the laboratory.
2.2.1.a Sample Chain of Custody and Contract Laboratory:
Chain-of-Custody procedures and records provide a means of tracing each sample from the time of collection through the shipment and final analyses. Proper Chain-of-Custody procedures also provide a written record of all persons handling the samples. The information necessary to relate sample locations for reporting purposes is documented with each sample. This information is essential to proper completion of a sample results report and typically includes client and facility information; unique sample identification number; date and time sampled; sampler name and signature; sample location including the room/area; and field sketches of sample locations.
Millennium Consulting Associates 9 Project No. 22015.2033
All sample analyses were performed by EMSL Laboratory, located in San Diego, CA. EMSL is a laboratory which is certified by the State of California Environmental Laboratory Accreditation Program (2713), the U.S.
Department of Commerce, National Institute of Standards and Technology (NIST) and is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP No. 200855-0) for bulk asbestos analyses.
2.2.1.b Asbestos Material Physical/Condition Assessment:
The U.S. EPA AHERA specifies that a physical assessment of all friable suspect material must be performed during the inspection. The physical condition assessment consists of determining the condition of the ACM, and the potential for future disturbance. AHERA lists seven categories in which to assess the current condition and potential for damage for those asbestos materials having an asbestos content greater than 1%. These are considered Asbestos Containing Materials (ACM). These categories are as follows:
1. Damaged or Significantly Damaged Friable Thermal System Insulation;
2. Damaged Friable Surfacing Material;
3. Significantly Damaged Friable Surfacing Material;
4. Damaged or Significantly Damaged Friable Miscellaneous Material;
5. ACM with potential for damage;
6. ACM with the potential for significant damage; and
7. Any remaining Friable ACM or Assumed Friable ACM.
Additionally, as part of the assessment and categorization of materials, the ACMs are further defined by the current condition of the ACM, and the potential for future damage. These are defined as follows:
1. Current Condition of ACM: Intact, damaged or significantly damaged. The criteria for determining the damaged and significantly damaged conditions are as follows:
a. Damaged: The overall damage is up to ten percent (≤10%) and/or any localized damage is up to twenty-five percent (≤25%).
b. Significantly damaged: The overall damage is greater than ten percent (>10%) and/or any localized damage is greater than (>25%).
2. Potential for Future Damage of ACM: Another step in the assessment process is to determine the potential for future damage or deterioration for material classified as good or fair. The potential for future damage was classified as High, Moderate, or Low for Human Contact, Vibration and Air Erosion.
3. Friability Rating: All material were given a friability rating and classified as either Friable ACM or Non-Friable ACM. Friable ACM is defined as any material that contains more than one percent (>1%) asbestos and can be crumbled, pulverized, or reduced to powder by hand pressure. It is a description of risk and refers to a material’s likeliness to release airborne fibers.
Millennium Consulting Associates 10 Project No. 22015.2033
3.0 BUILDING SUMMARY
BUILDING 126 – MAIN HOSPITAL BUILDING
Building No. 126 is the Main Hospital Building and was built in 1967. The building has one basement and eleven floors and is approximately 300,000 ft2 in size. The structure is concrete, the floors are concrete and the roof is built-up bituminous asphalt. The building is considered to be in good overall condition.
4.0 SURVEY RESULTS
4.1 ACM Data Results
4.1.1 Summary of Previous Sampling Events:
Millennium reviewed twelve (12) documents detailing previous asbestos-related inspections and abatement activities associated with Building 1. The documents include the following:
1. Limited Asbestos Inspection, prepared by H2 Environmental, Project #206901AS, May 2001;
2. Facility Wide Survey, prepared by H2 Environmental, Project #1354510AS, March 2011;
3. Asbestos Abatement event, prepared by H2 Environmental, Project #1390211AM – abatement of
1000 SF of floor tile/mastic at the main corridor, April 2011;
4. Limited Asbestos Inspection, prepared by H2 Environmental, Project #1443011AS, June 2011;
Type
Asbestos Quantity
Material Description Color
Friable
ACBM
Concord Analysis, 1997
Ceiling cavities/mechanical chases throughout
Chrysotile Unreported
Thermal System
Insulation on piping
Beige/white/gray Friable
Concord Analysis, 1997 and H2, 2011
E115, E131, E170, E170, E153, E149, ER Waiting Room, W128, W131, W170, W231V, W231S, E222, E227, E223A, 2nd Flrr Corridor C2-2- 2, Rm 227, , E231, E247, , W231V, !st Fl W102, W105,, E167, , W128F, W128C, W128L, W128
Chrysotile Unreported
Floor (where tile is
ND)/carpet mastic
Black Non
Friable
Concord
Analysis, 1997 and H2, 2011
Corridor @ W142, W111, Corridor @
W170, W126 Chrysotile Unreported
Floor Tile/Mastic
Brown/Black
Millennium Consulting Associates 11 Project No. 22015.2033
Type
Asbestos Quantity
Material Description Color
Friable
ACBM
Concord
Analysis, 1997 and H2, 2011
W147 (under carpet), Waiting
Area, 2nd Flr Corridor C2-2-2, 1st Flr W161A, Corridor DC-C5, MC-C3
Chrysotile Unreported Floor
Tile/Mastic Red/Black
Non
Friable
Concord
Analysis, 1997 and H2, 2011
Corridor @ W227, Corridor @ W215, , Corridor @
W242, E252A, SE
entry to Kitchen, , Rm 40 (under carpet), Rm 42, 1st
Flr W164, Chrysotile Unreported Floor
Tile/Mastic Beige/Black
Non
Friable
Concord
Analysis, 1997 and H2, 2011
W212, corridor @ W212, #9
Treatment Room, E240, , E229
Chrysotile Unreported Floor
Tile/Mastic Gray/Black
Non
Friable
Concord
Analysis, 1997 and H2, 2011
W227, E229, , R42, R40, Chrysotile Unreported Joint
Compound Beige
Non Friable
H2, 2011 Penthouse, N, NW, S
Chrysotile
<1%
8,000 SF
Exterior Stucco
Unreported Non
Friable
H2, 2011
11th Flr Mech Rm 1131, 1132, 7th Flr, 6th Fl, 4th Flr, 3rd
Flr
Chrysotile <1%
100,000 SF
Joint
Compound White
Non Friable
H2, 2011 3rd Flr Rm 312 Chrysotile 100 SF Carpet Mastic Black/Yellow
Millennium Consulting Associates 12 Project No. 22015.2033
4.1.2 FINDINGS OF MILLENNIUM 2014 TRIENNIAL SURVEY & ASSESSMENT
Millennium conducted a site inspection and assessment of Building 126 in March 2015. A total of one hundred fifty two (152) bulk samples were collected within building 126 and then analyzed on a layer-by-layer basis using polarized light microscopy (PLM).
The results of the March, 2015 sampling event are as follows:
Qty.
Asbestos Content / Type
VALB-126-F1.1 ROOM 435 12X12 RESILIENT
FLOOR TILE
SEAFOAM - FLOOR
TILE AQUA N/A ND
VALB-126-F1.1 ROOM 435 12X12 RESILIENT
FLOOR TILE
SEAFOAM - MASTIC YELLOW N/A ND
VALB-126-F1.2 ROOM 126-465 12X12 RESILIENT
FLOOR TILE
SEAFOAM - FLOOR
TILE AQUA N/A ND
VALB-126-F1.2 ROOM 126-465 12X12 RESILIENT
FLOOR TILE
SEAFOAM - MASTIC YELLOW N/A ND
VALB-126-F1.3 ROOM 126-466 12X12 RESILIENT
FLOOR TILE
SEAFOAM AQUA N/A ND
VALB-126-F2.1 ROOM E236 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE WHITE 1
<1 Chrysotile
VALB-126-F2.1 ROOM E236 12X12 RESILIENT
FLOOR TILE -
MASTIC WHITE N/A ND
VALB-126-F3.1 ROOM 1138 1 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE WHITE N/A ND
VALB-126-F3.1 ROOM 1138 12X12 RESILIENT
FLOOR TILE -
MASTIC WHITE N/A ND
VALB-126-F4.1 ROOM CC11-2 12X12 RESILIENT
FLOOR TILE
SEAFOAM - FLOOR
TILE BLUE 1
<1 Chrysotile
VALB-126-F4.1 ROOM CC11-2 12X12 RESILIENT
SEAFOAM - MASTIC BLUE N/A ND
Millennium Consulting Associates 13 Project No. 22015.2033
Qty.
Asbestos Content / Type
VALB-126-F4.2 ROOM W132 12X12 RESILIENT
FLOOR TILE
SEAFOAM - FLOOR
TILE BLUE 1
<1 Chrysotile
VALB-126-F4.2 ROOM W132 12X12 RESILIENT
FLOOR TILE
SEAFOAM - MASTIC BLUE N/A ND
VALB-126-F4.3 ROOM EC-C6 12X12 RESILIENT
FLOOR TILE
SEAFOAM - FLOOR
TILE BLUE 1
<1 Chrysotile
VALB-126-F4.3 ROOM EC-C6 12X12 RESILIENT
FLOOR TILE
SEAFOAM - MASTIC BLUE N/A ND
VALB-126-F5.1 ROOM 632 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE NAVY BLUE 1
<1 Chrysotile
VALB-126-F5.1 ROOM 632 12X12 RESILIENT
FLOOR TILE -
MASTIC NAVY BLUE N/A ND
VALB-126-F6.1 ROOM 1040 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE MAUVE 1
<1 Chrysotile
VALB-126-F6.1 ROOM 1040 12X12 RESILIENT
FLOOR TILE -
MASTIC MAUVE N/A ND
VALB-126-F6.2 ROOM CC-10-8 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE MAUVE 1
<1 Chrysotile
VALB-126-F6.2 ROOM CC-10-8 12X12 RESILIENT
FLOOR TILE - MASTIC MAUVE N/A ND
VALB-126-F6.3 ROOM CC-10-5 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE MAUVE 1
<1 Chrysotile
VALB-126-F6.3 ROOM CC-10-5 12X12 RESILIENT
FLOOR TILE -
MASTIC MAUVE N/A ND
VALB-126-F7.1 ROOM EC-C2 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE RUST 1
2% Chrysotile
VALB-126-F7.1 ROOM EC-C2 12X12 RESILIENT
FLOOR TILE -
MASTIC RUST 1
4% Chrysotile
VALB-126-F8.1 ROOM 356A 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE BROWN 1
2%
Millennium Consulting Associates 14 Project No. 22015.2033
Qty.
Asbestos Content / Type
VALB-126-F8.1 ROOM 356A 12X12 RESILIENT
FLOOR TILE -
MASTIC BROWN N/A ND
VALB-126-F8.2 ROOM W160 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE BROWN 1
2% Chrysotile
VALB-126-F8.2 ROOM W160 12X12 RESILIENT
FLOOR TILE -
MASTIC BROWN N/A ND
VALB-126-F8.3 ROOM W108 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE BROWN 1
2% Chrysotile
VALB-126-F8.3 ROOM W108 12X12 RESILIENT
FLOOR TILE -
MASTIC BROWN 1
4% Chrysotile
VALB-126-F9.1 ROOM C126-6-5 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE BROWN N/A ND
VALB-126-F9.1 ROOM C126-6-5 12X12 RESILIENT
FLOOR TILE -
MASTIC BROWN N/A ND
VALB-126-F10.1 ROOM C2-2-5 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE BROWN N/A ND
VALB-126-F10.1 ROOM C2-2-5 12X12 RESILIENT
FLOOR TILE -
MASTIC BROWN N/A ND
VALB-126-F10.2 ROOM 1044 1 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE BROWN N/A ND
VALB-126-F10.2 ROOM 1044 12X12 RESILIENT
FLOOR TILE -
MASTIC BROWN N/A ND
VALB-126-F10.3 ROOM DC-C3 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE BROWN N/A ND
VALB-126-F10.3 ROOM DC-C3 12X12 RESILIENT
FLOOR TILE -
MASTIC BROWN N/A ND
VALB-126-F11.1 ROOM 1013 12X12 RESILIENT
FLOOR TILE
SEAFOAM - FLOOR
TILE PINK N/A ND
VALB-126-F11.1 ROOM 1013 12X12 RESILIENT
SEAFOAM - MASTIC PINK N/A ND
Millennium Consulting Associates 15 Project No. 22015.2033
Qty.
Asbestos Content / Type
VALB-126-F11.2-
Floor Tile
ROOM C126-458 12X12 RESILIENT
FLOOR TILE
SEAFOAM - FLOOR
TILE PINK N/A ND
VALB-126-F11.2 ROOM C126-458 12X12 RESILIENT
FLOOR TILE
SEAFOAM - MASTIC PINK N/A ND
VALB-126-F11.3 ROOM 440 12X12 RESILIENT
FLOOR TILE
SEAFOAM - FLOOR
TILE PINK N/A ND
VALB-126-F11.3 ROOM 440 12X12 RESILIENT
FLOOR TILE
SEAFOAM - MASTIC PINK N/A ND
VALB-126-F12.1 ROOM 2 FAC 1 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE BROWN N/A ND
VALB-126-F12.1 ROOM 2 FAC 1 12X12 RESILIENT
FLOOR TILE -
MASTIC BROWN N/A ND
VALB-126-F13.1 ROOM 1120 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE OLIVE N/A ND
VALB-126-F13.1 ROOM 1120 E 12X12 RESILIENT
FLOOR TILE -
MASTIC OLIVE N/A ND
VALB-126-F14.1 ROOM W213 12X12 RESILIENT
FLOOR TILE -
MASTIC 1 BLACK N/A ND
VALB-126-F14.1 ROOM W213 12X12 RESILIENT
FLOOR TILE - FLOOR
TILE BLACK 1
2% Chrysotile
VALB-126-F14.1 ROOM W213 12X12 RESILIENT
FLOOR TILE -
MASTIC 2 BLACK 1
6% Chrysotile
VALB-126-F15.1 ROOM 000 16X16 VINYL FLOOR
TILE - VINYL SHEET
FLOORING
MULTI-
COLOR N/A ND
VALB-126-F15.1 ROOM 000 16X16 VINYL FLOOR
TILE - MASTIC
MULTI-
COLOR N/A ND
VALB-126-F15.2 ROOM E201 1 16X16 VINYL FLOOR
TILE - VINYL FLOOR
TILE
MULTI-
COLOR N/A ND
VALB-126-F15.2 ROOM E201 16X16 VINYL FLOOR
TILE - MASTIC
MULTI-
COLOR N/A ND
Millennium Consulting Associates 16 Project No. 22015.2033
Qty.
Asbestos Content / Type
VALB-126-F16.1 ROOM 132A 16X16 VINYL FLOOR
TILE -VINYL FLOOR
TILE BEIGE N/A ND
VALB-126-F16.1 ROOM 132A 16X16 VINYL FLOOR
TILE - MASTIC BEIGE N/A ND
VALB-126-F17.1 ROOM EC-C2 16X16 VINYL FLOOR
TILE TAN N/A ND
VALB-126-F18.1 ROOM CC-200 24X24 VINYL FLOOR
TILE BROWN N/A ND
VALB-126-F19.1 ROOM CC-200 24X24 VINYL FLOOR
TILE BEIGE N/A ND
VALB-126-F20.1 ROOM D260 24X24 VINYL FLOOR
TILE - VINYL FLOOR
TILE GRAY N/A ND
VALB-126-F20.1 ROOM D260 24X24 VINYL FLOOR
TILE - MASTIC GRAY N/A ND
VALB-126-F21.1 ROOM E-C2-2.2 24X24 VINYL FLOOR
TILE LIGHT GRAY N/A ND
VALB-126-F22.1 ROOM CC-200 24X24 VINYL FLOOR
TILE YELLOW N/A ND
VALB-126-F23.1 ROOM D245 24X24 VINYL FLOOR
TILE TAN N/A ND
VALB-126-F24.1 ROOM W201 RESILIENT FLOOR -
SHEET FLOORING WHITE N/A ND
VALB-126-F24.1 ROOM W201 RESILIENT FLOOR
SHEETING - MASTIC WHITE N/A ND
VALB-126-F25.1 ROOM 416 RESILIENT FLOOR
SHEETING - SHEET
FLOORING PINK/BLUE N/A ND
VALB-126-F25.1 ROOM 416 RESILIENT FLOOR
SHEETING - MASTIC PINK/BLUE N/A ND
VALB-126-F26.1 ROOM C5-1C RESILIENT FLOOR
SHEETING - SHEET
FLOORING BLUE N/A ND
VALB-126-F26.1 ROOM C5-1C RESILIENT FLOOR
SHEETING - MASTIC BLUE N/A ND
VALB-126-F26.2 ROOM 532D RESILIENT FLOOR
SHEETING BLUE N/A ND
VALB-126-F27.1 ROOM 509 RESILIENT FLOOR
SHEETING - SHEET
FLOORING
LIGHT
BROWN N/A ND
VALB-126-F27.1 ROOM 509 RESILIENTFLOOR
SHEETING - MASTIC
LIGHT
BROWN N/A ND
VALB-126-F28.1 ROOM E123 RESILIENT FLOOR
SHEETING - VINYL
SHEET FLOORING GRAY N/A ND
Millennium Consulting Associates 17 Project No. 22015.2033
Qty.
Asbestos Content / Type
VALB-126-F28.1 ROOM E123 RESILIENT FLOOR
SHEETING- MASTIC GRAY N/A ND
VALB-126-F29.1 ROOM E155 RESILIENT FLOOR
SHEETING GREEN N/A ND
VALB-126-F30.1 ROOM D223 RESILIENT FLOOR
SHEETING - SHEET
FLOORING GRAY N/A ND
VALB-126-F30.1 ROOM D223 RESILIENT FLOOR
SHEETING - MASTIC GRAY N/A ND
VALB-126-F31.1 ROOM 253 RESILIENT FLOOR
SHEETING - SHEET
FLOORING WHITE N/A ND
VALB-126-F31.1 ROOM 253 RESILIENT FLOOR
SHEETING - MASTIC WHITE N/A ND
VALB-126-F32.1 ROOM D257 RESILIENT FLOOR
SHEETING GRAY N/A ND
VALB-126-F32.2 ROOM D251 RESILIENT FLOOR
SHEETING GRAY N/A ND
VALB-126-F33.1 ROOM E-C2-2.2 RESILIENT FLOOR
SHEETING - SHEET
FLOORING DARK GRAY N/A ND
VALB-126-F33.1 ROOM E-C2-2.2 RESILIENT FLOOR
SHEETING - MASTIC DARK GRAY N/A ND
VALB-126-F34.1 ROOM 519 RESILIENT FLOOR
SHEETING - SHEET
FLOORING GREEN N/A ND
VALB-126-F34.1 ROOM 519 RESILIENT FLOOR
SHEETING - MASTIC GREEN N/A ND
VALB-126-F34.2 ROOM E122 RESILIENT FLOOR
SHEETING GREEN N/A ND
VALB-126-F35.1 ROOM 509 RESILIENT FLOOR
SHEETING BEIGE N/A ND
VALB-126-F35.2 ROOM E122 RESILIENT FLOOR
SHEETING BEIGE N/A ND
VALB-126-F35.3 ROOM 1053 RESILIENT FLOOR
SHEETING - SHEET
FLOORING BEIGE N/A ND
VALB-126-F35.3 ROOM 1053 RESILIENT FLOOR
SHEETING - MASTIC BEIGE N/A ND
VALB-126-F36.1 ROOM E122 RESILIENT FLOOR
SHEETING BROWN N/A ND
VALB-126-F37.1 ROOM 509 RESILIENT FLOOR
SHEETING - SHEET
FLOORING
LIGHT
BROWN N/A ND
VALB-126-F37.1 ROOM 509 RESILIENT FLOOR
SHEETING - MASTIC
LIGHT
BROWN N/A ND
Millennium Consulting Associates 18 Project No. 22015.2033
Qty.
Asbestos Content / Type
VALB-126-F38.1 ROOM 537 RESILIENT FLOOR
SHEETING - SHEET
FLOORING
LIGHT
BROWN N/A ND
VALB-126-F38.1 ROOM 537 RESILIENT FLOOR
SHEETING - MASTIC
LIGHT
BROWN N/A ND
VALB-126-F39.1 ROOM 955 RESILIENT FLOOR
SHEETING - SHEET
FLOORING OLIVE N/A ND
VALB-126-F39.1 ROOM 955 RESILIENT FLOOR
SHEETING - MASTIC OLIVE N/A ND
VALB-126-F39.2 ROOM 932G RESILIENT FLOOR
SHEETING - SHEET
FLOORING OLIVE N/A ND
VALB-126-F39.2 ROOM 932G RESILIENT FLOOR
SHEETING - MASTIC OLIVE N/A ND
VALB-126-F39.3 ROOM 905 RESILIENT FLOOR
SHEETING OLIVE N/A ND
VALB-126-F40.1 ROOM 509 RESILIENT FLOOR
SHEETING - SHEET
FLOORING
LIGHT
BROWN N/A ND
VALB-126-F40.1 ROOM 509N RESILIENT FLOOR
SHEETING - MASTIC
LIGHT
BROWN N/A ND
VALB-126-F41.1 ROOM E226 CARPET GLUE /
UNDER CARPET GRAY N/A ND
VALB-126-F42.1 ROOM E226 CARPET GLUE /
UNDER CARPET BROWN N/A ND
VALB-126-F43.1 ROOM E226 CARPET GLUE /
UNDER CARPET BLUE?BROWN N/A ND
VALB-126-M1.1 ROOM E240 SINK
UNDERCOATING WHITE N/A ND
VALB-126-M2.1 ROOM E205 SINK
UNDERCOATING BLACK N/A ND
VALB-126-M2.2 ROOM E222 SINK
UNDERCOATING BLACK N/A ND
VALB-126-M2.3 ROOM E223 SINK
UNDERCOATING BLACK N/A ND
VALB-126-M3.1 ROOM 926 HVAC SEALANT YELLOW N/A ND
VALB-126-M4.1 ROOM 1131
@126-ST-4 EAST HVAC SEALANT WHITE N/A ND
VALB-126-M5.1 ROOM E103 FIRESTOP - CAULK BLUE N/A ND
VALB-126-M5.1 ROOM E103 FIRESTOP- JOINT
COMPOUND BLUE N/A ND
VALB-126-M5.2 ROOM 1131 FIRESTOP - CAULK BLUE N/A ND
VALB-126-M5.2 ROOM 1131 FIRESTOP - JOINT
COMPOUND BLUE 1
Millennium Consulting Associates 19 Project No. 22015.2033
Qty.
Asbestos Content / Type
VALB-126-M5.3 ROOM C126-6-3 FIRESTOP BLUE N/A ND
VALB-126-M6.1 ROOM MC-C-7 @
W158 FIRESTOP RED N/A ND
VALB-126-M6.2 ROOM 519 FIRESTOP RED N/A ND
VALB-126-M6.3 ROOM CC-9-10 FIRESTOP RED N/A ND
VALB-126-M6.4 ROOM MC-C2 FIRESTOP RED N/A ND
VALB-126-M6.5 ROOM 49 FIRESTOP RED N/A ND
VALB-126-M6.6 ROOM C7-1A FIRESTOP RED N/A ND
VALB-126-M6.7 ROOM C11-1 FIRESTOP RED N/A ND
VALB-126-M7.1 ROOM 000 4" COVEBASE SILVER N/A ND
VALB-126-M8.1 ROOM CC-202 6" COVEBASE - COVE
BASE SILVER N/A ND
VALB-126-M8.1 ROOM CC-202 6" COVEBASE -
MASTIC SILVER N/A ND
VALB-126-M8.2 ROOM D260 6" COVEBASE -
COVE BASE SILVER N/A ND
VALB-126-M8.2 ROOM D260 6" COVEBASE -
MASTIC SILVER N/A ND
VALB-126-M8.3 ROOM E-CC-2.2 6" COVEBASE -
COVE BASE SILVER N/A ND
VALB-126-M8.3 ROOM E-CC-2.2 6" COVEBASE -
JOINT COMPOUND SILVER N/A ND
VALB-126-M9.1 ROOM 359A 6" COVEBASE -
COVE BASE BEIGE N/A ND
VALB-126-M9.1 ROOM 359A 6" COVEBASE -
MASTIC BEIGE N/A ND
VALB-126-M9.1 ROOM 359A 6" COVEBASE -
JOINT COMPOUND BEIGE N/A ND
VALB-126-M10.1 ROOM CC-10-1 4" COVEBASE -
COVE BASE BEIGE N/A ND
VALB-126-M10.1 ROOM CC-10-1 4" COVEBASE -
MASTIC BEIGE N/A ND
VALB-126-M10.2 ROOM 351 4" COVEBASE -
COVE BASE BEIGE N/A ND
VALB-126-M10.2 ROOM 351 4" COVEBASE -
MASTIC BEIGE N/A ND
VALB-126-M10.3 ROOM 438 4" COVEBASE -
COVE BASE BEIGE N/A ND
VALB-126-M10.3 ROOM 438 4" COVEBASE -
MASTIC BEIGE N/A ND
VALB-126-M12.1 ROOM D212 FIREPROOFING TAN N/A ND
VALB-126-M11.1 ROOM C5-1C @
ROOM 503 FIREPROOFING GRAY N/A ND
VALB-126-M11.2 ROOM 517 FIREPROOFING GRAY N/A ND
Millennium Consulting Associates 20 Project No. 22015.2033
Qty.
Asbestos Content / Type
VALB-126-M11.3 ROOM D212 FIREPROOFING GRAY N/A ND
VALB-126-M11.4 ROOM 1131 FIREPROOFING GRAY N/A ND
VALB-126-M11.5 ROOF
PENETRATION
NORTHWEST FIREPROOFING GRAY N/A ND
VALB-126-M11.6 ROOM E-C2-8 FIREPROOFING GRAY N/A ND
VALB-126-M11.7 ROOM 126-C7-2A FIREPROOFING GRAY N/A ND
VALB-126-W1.1 ROOM 101 PLASTER SKIMCOAT WHITE N/A ND
VALB-126-W1.2 ROOM 502 PLASTER SKIMCOAT WHITE N/A ND
VALB-126-W1.3 ROOM 1102 PLASTER SKIMCOAT
- SKIM COAT WHITE N/A ND
VALB-126-W1.3 ROOM 1102 PLASTER SKIMCOAT
- PLASTER TAN N/A ND
VALB-126-W1.4 ROOM C126-B-1 PLASTER SKIMCOAT-
SKIM COAT WHITE N/A ND
VALB-126-W1.4 ROOM C126-B-1 PLASTER SKIMCOAT-
PLASTER TAN N/A ND
VALB-126-W1.5 ROOM 901 PLASTER SKIMCOAT WHITE N/A ND
VALB-126-W1.6 ROOM C5-1C PLASTER SKIMCOAT WHITE N/A ND
VALB-126-W1.7 ROOM C11-6 PLASTER SKIMCOAT
- SKIM COAT WHITE N/A ND
VALB-126-W1.7 ROOM C11-6 PLASTER SKIMCOAT
- PLASTER TAN N/A ND
VALB-126-W2.1 ROOM MC-C3 DRYWALL
SKIMCOAT - SKIM
COAT BEIGE N/A ND
VALB-126-W2.1 ROOM MC-C3 DRYWALL
SKIMCOAT -
DRYWALL WHITE N/A ND
VALB-126-W2.2 ROOM C126-B-4 DRYWALL
SKIMCOAT WHITE N/A ND
VALB-126-W2.3 NO SAMPLE N/A ND
VALB-126-W2.4 ROOM C11-6 DRYWALL
SKIMCOAT WHITE N/A ND
VALB-126-W2.5 ROOM 1013 DRYWALL
SKIMCOAT WHITE N/A ND
VALB-126-W2.6 ROOM C5-1C DRYWALL
SKIMCOAT WHITE N/A ND
VALB-126-W2.7 ROOM C126-471 DRYWALL
SKIMCOAT WHITE N/A ND
VALB-126-C1.1 ROOM 9FAC4 CEILING
WALLBOARD WHITE N/A ND
Millennium Consulting Associates 21 Project No. 22015.2033
Qty.
Asbestos Content / Type
VALB-126-C1.1 ROOM 9FAC4 CEILING - JOINT
COMPOUND BEIGE 1
<1 Chrysotile
VALB-126-C1.2 ROOM 11TH
FLOOR ELEC
CEILING
WALLBOARD WHITE N/A ND
VALB-126-C1.2 ROOM 11TH
FLOOR ELEC
CEILING - JOINT
COMPOUND WHITE 1
2% Chrysotile
VALB-126-C1.3 ROOM 1FAC2 CEILING
WALLBOARD WHITE N/A ND
VALB-126-C1.3 ROOM 1FAC2 CEILING - JOINT
COMPOUND WHITE N/A ND
VALB-126-C1.4 ROOM 5TH
FLOOR ELEC
CEILING
WALLBOARD WHITE N/A ND
VALB-126-C1.4 ROOM 5TH
FLOOR ELEC
CEILING - JOINT
COMPOUND WHITE N/A ND
VALB-126-C1.5 ROOM W146 CEILING
WALLBOARD WHITE N/A ND
VALB-126-C1.5 ROOM W146 CEILING - JOINT
COMPOUND WHITE N/A ND
VALB-126-C1.6 ROOM 10FAC1 CEILING -
WALLBOARD WHITE N/A ND
VALB-126-C1. ROOM 10FAC1 CEILING - JOINT
COMPOUND WHITE 1
<1 Chrysotile
VALB-126-C1.7 ROOM 33 CEILING JOINT
COMPOUND WHITE N/A ND
VALB-126-C1.7 ROOM 33 CEILING
WALLBOARD WHITE N/A ND
VALB-126-C2.1 ROOM 17 CEILING PLASTER -
FINISH COAT WHITE N/A ND
VALB-126-C2.1 ROOM 17 CEILING PLASTER -
BASE COAT BEIGE N/A ND
VALB-126-C2.2 ROOM 15B CEILING PLASTER -
FINISH COAT WHITE N/A ND
VALB-126-C2.2 ROOM 15B CEILING PLASTER -
BASE COAT BEIGE N/A ND
VALB-126-C2.3 ROOM 509 CEILING PLASTER?? GRAY N/A ND
VALB-126-C3.1 ROOM B15 2X4 ACOUSTIC
CEILING TILE NO
HOLE SOLID
DRYWALL PINK N/A ND
VALB-126-C4.1 ROOM E170 2X2X12X12
ACOUSTIC CEILING
TILE PINHOLE WHITE N/A ND
VALB-126-C5.1 ROOM W164 2X4 ACOUSTIC
CEILING TILE BIG
PINHOLE WHITE N/A ND
Millennium Consulting Associates 22 Project No. 22015.2033
Qty.
Asbestos Content / Type
VALB-126-C6.1 ROOM W164 2X4 ACOUSTIC
CEILING TILE
PINHOLE CIRCULAR WHITE N/A ND
VALB-126-C7.1 ROOM 351 2X4 ACOUSTIC
CEILING TILE
LARGE PINHOLE
CIRCULAR WHITE N/A ND
VALB-126-C8.1 ROOM MC-C3 2X2 ACOUSTIC
CEILING TILE NO
HOLE WHITE N/A ND
VALB-126-C9.1 ROOM 718 2X4 ACOUSTIC
CEILING TILE NO
HOLE WHITE N/A ND
VALB-126-C9.2 ROOM D245 2X4 ACOUSTIC
CEILING TILE NO
HOLE WHITE N/A ND
VALB-126-C10.1 ROOM W151 2X4 ACOUSTIC
CEILING TILE
PINHOLE BIG WORM WHITE N/A ND
VALB-126-C11.1 ROOM W169 2X4 ACOUSTIC
CEILING TILE
PINHOLE WHITE N/A ND
VALB-126-C12.1 ROOM 112 2X4 ACOUSTIC
CEILING TILE
PINHOLE WORM WHITE N/A ND
VALB-126-C13.1 ROOM C5-C1@
ROOM 505
2X4 ACOUSTIC
CEILING TILE NO
HOLE ROUGH WHITE N/A ND
VALB-126-C14.1 ROOM B40 2X2 ACOUSTIC
CEILING TILE NO
HOLE ROUGH WHITE N/A ND
VALB-126-C15.1 ROOM B40 2X4X2 ACOUSTIC
CEILING TILE NO
HOLE ROUGH WHITE N/A ND
VALB-126-C16.1 ROOM 112 2X2 ACOUSTIC
CEILING TILE
PINHOLE WORM WHITE N/A ND
VALB-126-M13.1 ROOM 625 HVAC SEALANT GRAY N/A ND
VALB-126-F44.1 ROOM D213 RESILIENT FLOOR
SHEETING WHITE N/A ND
VALB-126-R1.1 11TH FLOOR
ROOF
SOUTHWEST
BUILT UP ROOF
GRAVEL BLACK N/A ND
Millennium Consulting Associates 23 Project No. 22015.2033
Qty.
Asbestos Content / Type
VALB-126-R1.2 11TH FLOOR
ROOF
PENTHOUSE
CENTER
BUILT UP ROOF
GRAVEL BLACK N/A ND
VALB-126-R1.3 11TH FLOOR
ROOF NORTH
BUILT UP ROOF
GRAVEL BLACK N/A ND
VALB-126-R2.1 11TH FLOOR
ROOF
PENTHOUSE
CENTER ROOF FLASHING BLACK N/A ND
VALB-126-R2.2 11TH FLOOR
ROOF
NORTHWEST ROOF FLASHING BLACK N/A ND
VALB-126-R3.1 11TH FLOOR
ROOF
PENETRATION
HOUSE CENTER
PENETRATION
MASTIC BLACK 1
2% Chrysotile
VALB-126-R3.2 11TH FLOOR
ROOF SOUTH
HVAC SUPPORT
PENETRATION BLACK N/A ND
VALB-126-R3.3 11TH FLOOR
ROOF
SOUTHWEST
PENETRATION
MASTIC BLACK N/A ND
VALB-126-R4.1 11TH FLOOR
ROOF EAST
HVAC SEALANT
GRAY - SEALANT 1 GRAY N/A ND
VALB-126-R4.1 11TH FLOOR
ROOF EAST
HVAC SEALANT
GRAY - SEALANT 2 TAN N/A ND
VALB-126-R4.2 2ND FLOOR
ROOF WEST
HVAC SEALANT
GRAY BLACK N/A ND
VALB-126-R5.1 2ND FLOOR
ROOF EAST
ROOF FLASHING
GRAY BLACK N/A ND
VALB-126-R5.2 2ND FLOOR
ROOF SOUTH
ROOF FLASHING
GRAY BLACK N/A ND
VALB-126-R5.3 2ND FLOOR
ROOF
NORTHWEST ROOF FLASHING BLACK N/A ND
VALB-126-R6.1 2ND FLOOR
ROOF WEST
PENETRATION
MASTIC
BLACK/GRAY BLACK 1
<1 Chrysotile
VALB-126-R6.2 2ND FLOOR
ROOF EAST
PENETRATION
MASTIC
BLACK/GRAY BLACK N/A ND
VALB-126-R6.3 2ND FLOOR
ROOF
SOUTHWEST
PENETRATION
MASTIC BLACK BLACK N/A ND
Millennium Consulting Associates 24 Project No. 22015.2033
5.0 CONCLUSIONS AND RECOMMENDATIONS
CONCLUSIONS
Based on this survey and a review of previous surveys, the following materials are present within Building 126 which contain asbestos:
Building 126:
Wallboard/joint compound systems: wallboard has consistently been reported as “ND”; joint compound has routinely been reported between <1% to 2% asbestos;
9” floor tile/mastic – reported at 2nd floor;
Floor tile mastic – under 12” beige w/ brown non ACM floor tile at: R218a, 2nd floor corridor, 1st floor Rm W128, MC-CS;
Floor tile mastic – under 12” off white w/ gray streak non ACM floor tile at: E231, E231a, E247;
Floor tile mastic – under 12” cream w/ gray streak non ACM floor tile at: Room W231v;
Floor tile mastic – under 12” cream w/ brown streak non ACM floor tile at: 2nd floor patient corridor C2-2, 1st floor room W102;
Floor tile mastic – under 12” blue/tan non ACM floor tile at: Room W128F, W128C, W128L;
Floor tile mastic – under 12” carpet non ACM floor tile at:E131, E170, E153,E149, W111, W131, W170, W218A, W231V, E222, E227, ER Waiting Room, W126, W227, W215, W262, 43, W128, W212, #9 treatment room, E240, E229, W142, W111, W170;
Gray/black floor insulation at W103
Note: Asbestos-Containing thermal insulation is anticipated to exist in concealed or otherwise limited access areas throughout.
Please refer to the Asbestos Laboratory Data in Appendix A in Appendix B for the complete Finish Schedule.
6.0 LIMITING CONDITIONS
Millennium Consulting conducted the survey in March 2015, in accordance with industry standards in existence at the time of the project. The conclusions and recommendations presented in this report are based on the applicable standards of our profession at the time this report was prepared. Copies of this report are furnished to provide factual data that were gathered and summarized in the report.
The data, analysis and recommendations submitted in this report are solely for use of the Client. It may not be relied upon for third party use. This report has been prepared for the exclusive use of the Client for specific application to the survey performed on the property; this Report is not a construction document and is not intended to replace a NESHAP’s pre-renovation assessment and investigation. Destructive investigation methods were part of this scope of work. This report may not be copied (except by our client) without the written permission of the Client. No other representation, expressed or implied, is made.
Millennium Consulting Associates 25 Project No. 22015.2033
Millennium appreciated having the opportunity to provide you with our asbestos-related services. Should you have any questions regarding this report or require assistance in the design, specification, management, and/or clearance testing for any future repairs, renovations and/or demolition projects, please do not hesitate to contact us.
Appendix A
Asbestos Laboratory Data
EMSL Analytical, Inc.
7916 Convoy Court,Building 4, Suite A, San Diego, CA 92111
Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.EMSL.com sandiegolab@emsl.com
431500652
CustomerID: MECA62
CustomerPO: 9491
ProjectID:
EMSL Order:
Attn: Jack McCubbin
Millennium Consulting Associates, Inc.
620 Contra Costa Blvd.
Suite 102
Pleasant Hill, CA 94523
Received: 03/05/15 11:12 AM
VALB ASB SURVEY BUILDING 126/22015.2033
Fax: (925) 808-6708
Phone: (925) 808-6700
Project:
3/12/2015Analysis Date:
Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
VALB-126-F1.1-
Floor Tile
431500652-0001
BLDG 126 RM
435 12X12
RESILIENT
FLOOR TILE
SEAFOAM
Blue None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F1.1-
Mastic
431500652-0001A
BLDG 126 RM
435 12X12
RESILIENT
FLOOR TILE
SEAFOAM
Yellow None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F1.2-
Floor Tile
431500652-0002
BLDG 126 RM
126-465 12X12
RESILIENT
FLOOR TILE SEA
Blue None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F1.2-
Mastic
431500652-0002A
BLDG 126 RM
126-465 12X12
RESILIENT
FLOOR TILE SEA
Yellow None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F1.3
431500652-0003
BLDG 126 RM
126-466 12X12
RESILIENT
FLOOR TILE SEA
Blue None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F2.1-
Floor Tile
431500652-0004
BLDG 126 RM
E236 12X12
RESILIENT
FLOOR TILE
WHITE
Gray
Non-Fibrous
Homogeneous
Chrysotile<1%Non-fibrous (other)100%
1Test Report PLM-7.28.9 Printed: 3/12/2015 12:21:24 PM
Derrick Tanner, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713
Initial report from 03/12/2015 12:21:24
Mariah Barfield (93) Natalia Toscano (89)
Shayne Boney (39) http://www.EMSL.com mailto:sandiegolab@emsl.com
Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.EMSL.com sandiegolab@emsl.com
431500652
CustomerID: MECA62
CustomerPO: 9491
ProjectID:
EMSL Order:
Attn: Jack McCubbin
Millennium Consulting Associates, Inc.
620 Contra Costa Blvd.
Suite 102
Pleasant Hill, CA 94523
Received: 03/05/15 11:12 AM
VALB ASB SURVEY BUILDING 126/22015.2033
Fax: (925) 808-6708
Phone: (925) 808-6700
Project:
3/12/2015Analysis Date:
Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
VALB-126-F2.1-
Mastic
431500652-0004A
BLDG 126 RM
E236 12X12
RESILIENT
FLOOR TILE
WHITE
Yellow None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F3.1-
Floor Tile
431500652-0005
BLDG 126 RM
1138 12X12
RESILIENT
FLOOR TILE
WHITE
White None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F3.1-
Mastic
431500652-0005A
BLDG 126 RM
1138 12X12
RESILIENT
FLOOR TILE
WHITE
Yellow None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F4.1-
Floor Tile
431500652-0006
BLDG 126 RM
CC11-2 12X12
RESILIENT
FLOOR TILE
SEAF
Blue
Non-Fibrous
Homogeneous
Chrysotile<1%Non-fibrous (other)100%
VALB-126-F4.1-
Mastic
431500652-0006A
BLDG 126 RM
CC11-2 12X12
RESILIENT
FLOOR TILE
SEAF
Yellow None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F4.2-
Floor Tile
431500652-0007
BLDG 126 RM
W132 12X12
RESILIENT
FLOOR TILE
SEAFOA
Blue
Non-Fibrous
Homogeneous
Chrysotile<1%Non-fibrous (other)100%
2Test Report PLM-7.28.9 Printed: 3/12/2015 12:21:24 PM
Derrick Tanner, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713
Initial report from 03/12/2015 12:21:24
Mariah Barfield (93) Natalia Toscano (89)
Shayne Boney (39)
Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.EMSL.com sandiegolab@emsl.com
431500652
CustomerID: MECA62
CustomerPO: 9491
ProjectID:
EMSL Order:
Attn: Jack McCubbin
Millennium Consulting Associates, Inc.
620 Contra Costa Blvd.
Suite 102
Pleasant Hill, CA 94523
Received: 03/05/15 11:12 AM
VALB ASB SURVEY BUILDING 126/22015.2033
Fax: (925) 808-6708
Phone: (925) 808-6700
Project:
3/12/2015Analysis Date:
Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
VALB-126-F4.2-
Mastic
431500652-0007A
BLDG 126 RM
W132 12X12
RESILIENT
FLOOR TILE
SEAFOA
Yellow None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F4.3-
Floor Tile
431500652-0008
BLDG 126 RM EC-
C6 12X12
RESILIENT
FLOOR TILE
SEAFO
Blue
Non-Fibrous
Homogeneous
Chrysotile<1%Non-fibrous (other)100%
VALB-126-F4.3-
Mastic
431500652-0008A
BLDG 126 RM EC-
C6 12X12
RESILIENT
FLOOR TILE
SEAFO
Yellow None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F5.1-
Floor Tile
431500652-0009
BLDG 126 RM
632 12X12
RESILIENT
FLOOR TILE
NAVY
Blue
Non-Fibrous
Homogeneous
Chrysotile<1%Non-fibrous (other)100%
VALB-126-F5.1-
Mastic
431500652-0009A
BLDG 126 RM
632 12X12
RESILIENT
FLOOR TILE
NAVY
Yellow None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F6.1-
Floor Tile
431500652-0010
BLDG 126 RM
1040 12X12
RESILIENT
FLOOR TILE
MAUVE
Pink
Non-Fibrous
Homogeneous
Chrysotile<1%Non-fibrous (other)100%
3Test Report PLM-7.28.9 Printed: 3/12/2015 12:21:24 PM
Derrick Tanner, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713
Initial report from 03/12/2015 12:21:24
Mariah Barfield (93) Natalia Toscano (89)
Shayne Boney (39)
Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.EMSL.com sandiegolab@emsl.com
431500652
CustomerID: MECA62
CustomerPO: 9491
ProjectID:
EMSL Order:
Attn: Jack McCubbin
Millennium Consulting Associates, Inc.
620 Contra Costa Blvd.
Suite 102
Pleasant Hill, CA 94523
Received: 03/05/15 11:12 AM
VALB ASB SURVEY BUILDING 126/22015.2033
Fax: (925) 808-6708
Phone: (925) 808-6700
Project:
3/12/2015Analysis Date:
Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
VALB-126-F6.1-
Mastic
431500652-0010A
BLDG 126 RM
1040 12X12
RESILIENT
FLOOR TILE
MAUVE
Yellow None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F6.2-
Floor Tile
431500652-0011
BLDG 126 RM CC-
10-8 12X12
RESILIENT
FLOOR TILE MAU
Pink
Non-Fibrous
Homogeneous
Chrysotile<1%Non-fibrous (other)100%
VALB-126-F6.2-
Mastic
431500652-0011A
BLDG 126 RM CC-
10-8 12X12
RESILIENT
FLOOR TILE MAU
Yellow None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F6.3-
Floor Tile
431500652-0012
BLDG 126 RM CC-
10-5 12X12
RESILIENT
FLOOR TILE MAU
Pink
Non-Fibrous
Homogeneous
Chrysotile<1%Non-fibrous (other)100%
VALB-126-F6.3-
Mastic
431500652-0012A
BLDG 126 RM CC-
10-5 12X12
RESILIENT
FLOOR TILE MAU
Yellow None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F7.1-
Floor Tile
431500652-0013
BLDG 126 RM EC-
C2 12X12
RESILIENT
FLOOR TILE
RUST
Rust
Non-Fibrous
Homogeneous
Chrysotile2%Non-fibrous (other)98%
4Test Report PLM-7.28.9 Printed: 3/12/2015 12:21:24 PM
Derrick Tanner, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. San Diego, CA NVLAP Lab Code 200855-0, CA ELAP 2713
Initial report from 03/12/2015 12:21:24
Mariah Barfield (93) Natalia Toscano (89)
Shayne Boney (39)
Phone/Fax: 858-499-1303 / (858) 499-1304 http://www.EMSL.com sandiegolab@emsl.com
431500652
CustomerID: MECA62
CustomerPO: 9491
ProjectID:
EMSL Order:
Attn: Jack McCubbin
Millennium Consulting Associates, Inc.
620 Contra Costa Blvd.
Suite 102
Pleasant Hill, CA 94523
Received: 03/05/15 11:12 AM
VALB ASB SURVEY BUILDING 126/22015.2033
Fax: (925) 808-6708
Phone: (925) 808-6700
Project:
3/12/2015Analysis Date:
Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy
VALB-126-F7.1-
Mastic
431500652-0013A
BLDG 126 RM EC-
C2 12X12
RESILIENT
FLOOR TILE
RUST
Black
Non-Fibrous
Homogeneous
Chrysotile4%Non-fibrous (other)96%
VALB-126-F8.1-
Floor Tile
431500652-0014
BLDG 126 RM
356A 12X12
RESILIENT
FLOOR TILE
BEIGE
Beige
Non-Fibrous
Homogeneous
Chrysotile2%Non-fibrous (other)98%
VALB-126-F8.1-
Mastic
431500652-0014A
BLDG 126 RM
356A 12X12
RESILIENT
FLOOR TILE
BEIGE
Yellow None Detected
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
VALB-126-F8.2-
Floor Tile
431500652-0015
BLDG 126 RM
W160 12X12
RESILIENT
FLOOR TILE
BEIGE
Beige
Non-Fibrous
Homogeneous
Chrysotile2%Non-fibrous…