36C26222Q0007.docx
DOCX document 21 KB Posted
- Attached to
- 6525--Radiation Monitoring Dosimetry Service
- Solicitation number
- 36C26222Q0007
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice
| SUBJECT* |
| Radiation Monitoring Dosimetry Service |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 90815 |
| SOLICITATION NUMBER* |
| 36C26222Q0007 |
| RESPONSE DATE/TIME/ZONE |
| 09-30-2021 12PM PACIFIC TIME, LOS ANGELES, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6525 |
| NAICS CODE* |
| 334510 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach CA 90815
POINT OF CONTACT*
Contract Specialist Hanan Chaaban Hanan.Chaaban@va.gov
PLACE OF PERFORMANCE
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
This is a combined synopsis/solicitation for commercial items in accordance with FAR Part 13 prepared with the format in Subpart 12.6, as supplemented with additional information included in this notice. The acquisition strategy will be an unrestricted competition to best meet the needs of the Government. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued.
(ii) Solicitation number 36C26222Q0007 is issued as a Request for Quotation (RFQ).
(iii) The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2021-04.
(iv) This is an unrestricted competition. This will be a firm fixed price award, provisions associated with this procurement; NAICS code 334510 and small business size standard is 1,250 employees.
(v) The technical specifications are listed as brand name or equal (FAR 52.211-6 is applicable). For equal items, please include technical specifications of the Radiation Dosimetry System and components. If technical specifications showing how the equal product meets the salient characteristics are not included, your quote will be considered non-responsive.
| Item # |
| Manufacturer |
| Description |
| Qty |
| 1 |
| Landauer |
| Luxel P Badge, monthly |
| 456 |
| 2 |
| Landauer |
| Luxel P Badge, quarterly |
| 956 |
| 3 |
| Landauer |
| ALARA memo per memo fee |
| 277 |
| 4 |
| Landauer |
| TLD Service (Type S), monthly |
| 168 |
| 5 |
| Landauer |
| TLD Service (Type S), quarterly |
| 32 |
| 6 |
| Landauer |
| Additional Dosimeters |
| 35 |
| 7 |
| Landauer |
| Luxel Unreturned Dosimeter Fee |
| 277 |
| 8 |
| Landauer |
| TLD/S Unreturned Dosimeter Fee |
| 10 |
| 9 |
| Landauer |
| ALARA annual reporting, annual fee |
| 1 |
| 10 |
| Landauer |
| ALARA annual reporting |
| 299 |
| 11 |
| Landauer |
| ALARA memo |
| 25 |
| 12 |
| Landauer |
| ALARA Quarterly Report base |
| 4 |
| 13 |
| Landauer |
| METER report |
| 12 |
| 14 |
| Landauer |
| NRC equivalent annual Form 5 |
| 1 |
| 15 |
| Landauer |
| NRC equivalent termination Form 5 |
| 299 |
| 16 |
| Landauer |
| Dosimetry Report copy different site |
| 810 |
| 17 |
| Landauer |
| RaySafe Realtime dosimetry |
| 2 |
| 18 |
| Landauer |
| Sort & Pack Fee, Single Ship Site |
| 18 |
| 19 |
| Landauer |
| RadFacts dashboard on myLDR per person |
| 2100 |
| 20 |
| Landauer |
| Statistical Summary Annual Report |
| 1 |
| 21 |
| Landauer |
| Statistical Summary Annual Report, per person |
| 299 |
| 22 |
| Landauer |
| ALARA Quarterly report per person |
| 700 |
****Please refer to Salient Characteristics for full details.**** NOTE: Potential offers must be aware that the items being acquired are procured as Brand Name or Equal. For those items that are “or equal”, a description of the salient characteristics outlined above. The FAR Clause 52.211-6 Brand Name or Equal applies to this acquisition. Any items quoted as equal not confirming to the requirements of clause 52.211-6 will be considered non- responsive and not considered for award.
Vendor Requirements:
1. Vendor shall provide delivery.
2. Vendor shall provide original equipment manufacturer (OEM) comprehensive warranty on the product(s) starting from the first day of delivery.
3. Vendor provides guarantee equipment is free of defects.
4. Authorized distributor letter
5. FOB Destination delivery shall occur within 90 business days after award to the following destination address: Department of Veterans Affairs VA Long Beach Healthcare System 5901 E. 7th St. Long Beach, CA 90822.
(xii) Quotes are to be received no later than 12:00PM PST, September 30, 2021 at email address: Hanan.Chaaban@va.gov, subject “Quote: # 36C26222Q0007 [VENDOR NAME]” late quotes shall not be accepted. Telephone responses shall not be accepted.
Salient Characteristics
1. Optically stimulated luminescence (OSL) [aluminum oxide Al2O3] whole-body dosimeters that can assess x-ray, gamma and beta exposure.
2. Lithium fluoride thermo-luminescent dosimeters (TLD) for assessing extremity exposure.
3. Neutron detection dosimeters that can assess fast, intermediate and thermal neutron exposure via solid state track etching. Neutron dosimeter shall have the capacity to be integrated into OSL whole-body dosimeters which will allow this dosimetry to be used as a whole body (personnel) dosimeter.
5. OSL whole-body dosimeters with emergency response re-read capabilities and the demonstrated ability to record radiation exposures as low as at 1 mrem increments. Including the ability to determine if the exposure was dynamic or static.
6. Master controls (dosimeters used for assessing background radiation during transit and storage) at no charge for all types of dosimeters.
7. OSL environmental (for a physical area such as a room) dosimeters.
8. Dosimeters will have permanent waterproof identification labels that cannot be smeared and/or removed and must provide barcode capability.
9. Dosimeters shall be identified by clearly visible icons that show where the dosimeter is to be worn.
10. Extremity badges shall be provided in at least three different sizes (e.g. small, medium, and large)
11. Color coding shall be used on all dosimeters to identify the specific wear period for that dosimeter.
12. Provide a real-time electronic dosimetry system and display that can be used in a clinical setting for high risk fluoroscopic procedures such as those in interventional radiology; vascular surgery; and cardiac catheterizations. The system must be wireless between the detector and the display. Dose reproducibility must be within 10 percent. The display screen must be at least 10” (diagonal viewing) and a touch screen.
The dosimetry provider must provide radiation monitoring services that meet the following criteria:
1. All radiation dosimetry services must meet current 10 CFR Part 20 reporting and recording requirements including appropriate controls to ensure the protection of personally identifiable information (PII). There must be a method to securely transmit PII between the vendor and the customer (e.g. via a secure internet site). The PII that will be transmitted includes full names, social security numbers, and dates of birth.
2. Reports of radiation exposures must be made on NRC Form 4 and NRC Form 5 or their equivalent. Reports must also be supplied electronically upon request in a format which meets the NRC "REMIT" format.
3. On-line support for on-line exposure reports, shipment tracking and account maintenance transactions (i.e. dosimeter add/delete/reactivate administrative capabilities, spare badge assignments, addition of previous exposure history to current records).
4. On-line support shall provide unlimited access to a helpline or equivalent.
5. Twenty-four hour emergency dosimeter processing service upon request.
6. Exposure reports shall be supplied within 8 working days from receipt of dosimeters.
7. A separate fetal dosimetry monitoring program which includes cumulative totals on exposures from year to year.
8. “As Low As Reasonably Achievable” (ALARA) notification and immediate phone notification and faxed memo for high exposures for any processed dosimeter exceeding specified ALARA trigger limits.
9. Termination report summaries of personnel radiation exposures shall be supplied within 30 days of notice of terminating a participant badge.
10. ALARA report summaries will be provided on a quarterly basis with an additional annual ALARA review summary for all monitored employees for all accounts.
11. Dosimeters shall be supplied seven business days before the beginning of any designated wear period to allow time for distribution once received.
12. Monthly report listing dosimetry results at other institutions in reports shall sum each individual’s exposures across all facilities for comparison with regulatory limits. This item applies when other institutions use the same dosimetry provider.
13. Reports of dosimeters that are unreturned during a wear period.
| 14. | At a minimum the provider must demonstrate the following internet-based capabilities: |
| a) Add, delete, and transfer personnel dosimeters including fetal badges | |
| b) Records access: downloadable exposure (dose) history, badge types, ALARA results, add lifetime cumulative exposure history from other institutions (if same dosimetry provider), search historical reports, and manage unreturned dosimeters |
| *= Required Field |
| Combined Synopsis/Solicitation Notice |
Combined Synopsis/Solicitation Notice
File details come from the government source that posted it. Updated .