36C26126Q1167.docx
DOCX document 19 KB Posted
- Solicitation number
- 36C26126Q1167
About this file
This is a Sources Sought Notice for fire damper inspection and repair services at the VA Central California Healthcare System. The Department of Veterans Affairs Network Contracting Office (NCO 21) is seeking contractor capability information to support future procurement decisions for Building 31 and Building 1 at the Fresno, California facility. The solicitation number is 36C26126Q1167, with responses due by 10:00 A.M. PDT on August 25, 2026, to contract specialist John Waldrip at john.waldrip@va.gov. This is a pre-solicitation announcement only; no formal solicitation currently exists, and the Government will not pay for submitted information or be bound by any terms presented.
The work involves repair and maintenance of fire dampers and associated components, classified under NAICS code 811310 with a small business size standard of $12.5 million. Required materials and components include pneumatic actuators, Belimo actuators (120V models with varying torque specifications), damper access doors in multiple sizes (6x6, 8x8, 10x10, and 14x14 configurations), drywall access doors, and fusible links. Interested contractors must provide company socioeconomic status, SAM registration number, relevant fire damper repair experience, similar project references, capabilities statement, and pricing estimates. The firm must address subcontracting limitations requiring at least 50 percent of personnel costs to be expended on the prime contractor's own employees. Contractors must maintain current SAM registration, and SDVOSB or VOSB firms must be verified through SBA certifications at the time of submission.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| DRAFT SOW-FIRE DAMPER REPAIR.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| Fire Damper Inspection Repairs VA Central California Healthcare System |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 89086 |
| SOLICITATION NUMBER* |
| 36C26126Q1167 |
| RESPONSE DATE/TIME/ZONE |
| 08-25-2026 4:00PM PACIFIC TIME, LOS ANGELES, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| J012 |
| NAICS CODE* |
| 811310 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 21
POINT OF CONTACT*
Contract Specialist John Waldrip john.waldrip@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| VA Central California Healthcare System |
2612 E. Clinton Avenue
Fresno CA
| POSTAL CODE |
| 93703 |
COUNTRY
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
THIS IS A SOURCES SOUGHT ANNOUNCEMENT ONLY.
No Solicitation is currently available.
All information contained in this Sources Sought Announcement is preliminary, as well as subject to modification, and is in no way binding on the Government. The Government will not pay for any information submitted in response to this request. The information requested will be used solely within the Department of Veterans Affairs to facilitate decision making and will not be disclosed outside of the Government. The determination of a procurement strategy, based upon the comments submitted in response to this Sources Sought Announcement, is solely within the discretion of the Government.
The applicable North American Industry Classification System (NAICS) Code is 811310- Commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance, and the small business size standard is $12.5 Million.
The Department of Veterans Affairs (VA) Network Contracting Office (NCO 21) is soliciting information from contractors that can provide Fire Damper Repair for the VA Central California Healthcare System. A draft copy of the Statement of Work (SOW) is attached.
Brief Description of Services See attached Draft SOW.
Capability Statement All interested contractors must respond by email to john.waldrip@va.gov before 10:00 A.M. PDT on August 25, 2026.
Please answer the following questions when responding:
1. What is your company’s Socioeconomic Status? (ex: small business, large business, SDVOSB, etc.)
a. If SDVOSB or VOSB, are you registered with the Small Business Administration?
https://www.sba.gov/
2. Provide Company’s legal name along with Unique Entity ID (SAM) number.
3. Primary point of contact, including phone number and e-mail address.
4. Capabilities Statement.
5. Describe experience in providing Fire Damper Repairs.
6. List other Projects (Government and Commercial) that are similar in scope and size.
7. As this is a service acquisition, the Small Business Administration and the Federal Acquisition Regulation have a Limitations on Subcontracting requirement. For all small businesses, to include SDVOSB and VOSB, “At least 50 percent of the cost of contract performance incurred for personnel shall be expended for employees of the concern.” See FAR 52.219-14 and FAR 52.219-27 available in full text at https://www.acquisition.gov/far/html/52_217_221.html
7a. Of the service actions listed above, which one(s) will your company perform as the prime contractor using its own personnel without subcontracting?
7b. With respect to the service actions listed above, which action(s) do you intend on subcontracting or using other than your company’s own personnel?
7c. Of those services that will be performed, approximately what percentage will be paid to the subcontractor(s)?
8. GSA Contract Number, if applicable.
9. Fill out the price estimate below.
*Failure to provide the information requested above (items 1-9) will be considered non-responsive and will not be considered a viable source.
RFQ number 36C26126Q1167 has been assigned and should be referenced on all correspondence regarding this announcement.
The Government will use this information when determining its business type decision.
This synopsis is not to be construed as a commitment by the Government and no contract will be awarded as a direct result of this Sources Sought announcement.
Notes: Contractors must have a current registration in the System for Award Management (SAM) at https://sam.gov/SAM/ SDVOSB and VOSB firms should be registered at the time of submission and verified at https://search.certifications.sba.gov/
| DESCRIPTION |
| ORDER QUANTITY |
| PRICE |
Building 31
| Pneumatic Actuator-No Compression and blades closed |
| 4 |
Building 1
| CD 5080 -10x10 -Damper Access Door |
| 3 |
| CD 5080 - 14x14 -Damper Access Door |
| 1 |
| CD 5080 - 6x6- Damper Access Door |
| 3 |
| CD 5080 - 8x8 -Damper Access Door |
| 1 |
| ED 2002 - 12x12 - Drywall Access Doors |
| 1 |
| ED 2002 - 14x14 - Drywall Access Doors |
| 1 |
Belimo Actuator - 120v FSLF120 US 30in - lb. - w/Additional Material (Brand‑Name or Equal):
• Torque: Minimum 30 in‑lb.
• Voltage: 120V AC
• Control Type: Fail‑Safe Spring Return
• Operation: On/Off or Floating (match existing control sequence)
• Shaft Compatibility: Round or Square damper shaft, ⅜" to ½"
• Environmental Rating: Commercial HVAC damper‑rated
• Certifications: UL/CSA listed or equivalent
• Warranty: Minimum 1 year
Belimo Actuator - 120v FSNF120 US 70in - lb. - w/Additional Material (Brand‑Name or Equal):
• Torque: Minimum 70 in‑lb
• Voltage: 120V AC
• Control Type: Fail‑Safe Spring Return
• Operation: On/Off or Floating (match existing control sequence)
• Shaft Compatibility: Round or Square damper shaft, ⅜" to ½"
• Environmental Rating: Commercial HVAC damper‑rated
• Certifications: UL/CSA listed or equivalent
• Warranty: Minimum 1 year
| Duro Dyne - 21151 - 8x12 Access Door 15"-18" RD |
| 1 |
| Model B fusible link |
| 1 |
See attached document: DRAFT SOW-FIRE DAMPER REPAIR.
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
File details come from the government source that posted it. Updated .