Building 4 Final Status Survey - List of Rooms (005) - Stanford Updates.pdf

PDF 381 KB Posted

Attached to
Historical Site Assessment and Radiological Final Status Survey
Solicitation number
36C26125Q0963
Issued by

About this file

This document is a laboratory room inventory spreadsheet detailing isotope usage across different rooms in Building 4 on the first and third floors. The spreadsheet includes columns for building, floor, room number, room function, net square footage, CRA (likely a laboratory identifier), possible isotopes used, and the last date of isotope use.

Key observations include multiple bench labs (A307, C301, C302, C310, C315, C320, C321) utilizing isotopes such as S35, P32, H3, C14, and I125, with the most recent usage dates ranging from 10/28/21 to 11/1/21. The rooms are primarily located on Floor 1 and Floor 3, with functions including offices, labs, equipment rooms, storage areas, and support spaces. Most rooms are associated with a specific CRA code (VMN238, VMN293, VMN523, VMN518), suggesting these are part of a coordinated research facility tracking radioactive material usage across different laboratory spaces.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bldg. Floor Room Function Net

SF

CRA Possible Isotopes Used Last Used

4 1 B108 Office 88 VMN518 H3, I125, P32, S35 9/20/07

4 1 B109 Office 991 VMN518 H3, I125, P32, S35 2/28/11

4 1 B110 (not found) VMN518 H3, I125, P32, S35 2/25/11

4 1 B111 Kitchen 73 VMN518 H3, I125, P32, S35 9/20/07

4 1 B112 Copy Room 104

4 1 B119 Office 285 VMN518 H3, I125, P32, S35 9/20/07

4 3 A300 Common Room

4 3 A301 Glass Wash 498 VMN238 P32, S35, I125, H3, C14, U238, Fe59, I131

5/21/10

4 3 A301A DI Water 60

4 3 A304 Storage 82

4 3 A306 Bench Lab 191

4 3 A307 Bench Lab 341 VMN523 S35, P32, H3, C14 10/29/21

4 3 A312 Instrument Room

4 3 A314 Storage 302 VMN293 S35, P32, I125, H3, C14, Cr51

5/27/22

4 3 C301 Bench Lab 601 VMN293 S35, P32, H3, C14, I125, Cr51

10/29/21

4 3 C302 Bench Lab 607 VMN293 S35, P32, H3, C14, I125, 4 3 C303 Bench Lab 289 VMN238 P32, S35, I125, H3, C14, Fe59, P33

10/28/21

4 3 C304 Equipment 257 VMN293 S35, P32, H3, C14, Cr51

4 3 C305 Housekeepi ng

4 3 C306 Instrument 123

4 3 C308 Office/Break Room

4 3 C309 Equipment Room

298 VMN238 P32, S35, I125, H3, C14,

Fe55

4 3 C310 Bench Lab 312 VMN293 S35, P32, H3, C14, I125, 4 3 C311 Bench Lab 475

4 3 C314 Storage 121

4 3 C315 Bench Lab 597 VMN238 P32, S35, I125, H3, C14, P33, Fe59

4 3 C316 Temp Controlled

260 VMN238 P32, S35, I125, H3, C14,

11/1/21

4 3 C317 Restroom 162

4 3 C318 Bench Lab 467 VMN278

4 3 C319 Bench Lab 474

4 3 C320 Bench Lab 550 VMN238 P32, S35, I125, H3, C14, 4 3 C321 Bench Lab 547 VMN523 S35, P32, H3, C14

11/1/21

First Floor

Third Floor

File details come from the government source that posted it. Updated .