FD

127 SF

Treatment Room

101 SF

Audiologist

101 SF

Audiologist

140 SF

Audiology Lab

91 SF

PT Office

50 SF

PT Equipment Storage

475 SF

PT Treatment & Exercise Area

108 SF

Dentist

122 SF

Asst / Hygenist

80 SF

Equip. Room

90 SF

Soiled Utility

142 SF

Operatories

142 SF

Operatories

105 SF

Dentist

144 SF

Operatories

75 SF

Clean Supply

92 SF

Medical Storage

104 SF

Clinician Office

106 SF

Exam Room

104 SF

Exam Room

109 SF

RN Office

101 SF

Supervisory PSA Room

218 SF

Main Clinic Reception Area

128 SF

Clinic Social Worker

125 SF

MAS Eligibility Screening Room

208 SF

Communications & Workroom

58 SF

Storage

215 SF

X-Ray Room

306 SF

Multi-Purpose Conference Room

112 SF

Clinician Office

106 SF

Clinician Office

104 SF

Server Room

77 SF

LVN

93 SF

Office

139 SF

Operatories

77 SF

X-ray

118 SF

Dental Lab

90 SF

Private Treatment

48 SF

Storage

104 SF

Clinician Office

106 SF

Clinician Office

104 SF

Clinician/Exam

106 SF

Clinician/Exam

108 SF

Exam Room

109 SF

Exam Room

109 SF

Exam Room

109 SF

Triage

109 SF

Exam Room

77 SF

LVN

77 SF

LVN

109 SF

Exam Room

109 SF

Exam Room

109 SF

Exam Room

109 SF

Exam Room

77 SF

LVN

75 SF

LVN

109 SF

Exam Room

108 SF

RN Workstn

176 SF

Psychiatrist

110 SF

Psychiatrist

110 SF

Psychiatrist

107 SF

Psych RN

110 SF

Psychologist

81 SF

Pharmacist

93 SF

Psych Intern

93 SF

Psych Intern

95 SF

Psych Intern

88 SF

Consult. Room

75 SF

Pharmacist

110 SF

Psychiatrist

110 SF

Psychologist

153 SF

Pharmacy

105 SF

Re-Adjust. Counselor

95 SF

Psych Intern

78 SF

Soiled Util

32 SF

Medical Store

383 SF

Main Clinic Waiting Room

161 SF

Shared Waiting

MISC

210 SF

Pharmacy Counter

97 SF

Psych RN

114 SF

Social Worker

66 SF

Storage

74 SF

Processing

119 SF

Procedure Rm

132 SF

Treatment Rm

43 SF

Changing

124 SF

Phlebotomy

123 SF

Toilet

81 SF

Clean Util

64 SF

Medical Storage

441 SF

Hallway

353 SF

Hallway

310 SF

Hallway

353 SF

Hallway

204 SF

Hallway

685 SF

Hallway

123 SF

South Entry

220 SF

Hallway

251 SF

Hallway

188 SF

Hallway

55 SF

Toilet

57 SF

Toilet

58 SF

Lab Toilet

746 SF

Hallway

746 SF

Hallway

Toilet

Toilet

Toilet

A

1.5 2 3 4 5 6 7 87.5

B

C

D

C.5

A.5

105C

SUP. OFFICE

105B

WORKSPACE

105D

ARMORY

105A

HOLDING AREA

156A

GYN RM

156B

GYN TOILET

MSA ROOM

LAB

COMMON HALLWAY

188 KING STREET #405, SAN FRANCISCO, CA 94107

415.525.9179 | designblitzsf.com

FIRST FLOOR PLANFIRST FLOOR PLANFIRST FLOOR PLANFIRST FLOOR PLAN

3841 BRICKWAY BLVD., SANTA ROSA, CA 95403

ISSUE DATE: 02/03/15

PROJECT NUMBER: 049-01

VETERANS ADMINISTRATION

1/8" = 1'-0" 1/8" = 1'-0" 1/8" = 1'-0" 1/8" = 1'-0"A1A1A1A1

1 VA FIRST FLOOR TENANT AREA

GROUND FLOOR EXISTING FLOOR PLAN BASED ON OWNER PROVIDED INFORMATION, FIELD VERIFICATION REQUIRED TO ESTABLISH ACCURACY (INCLUDING INDICATED PLUMBING FIXTURE LOCATIONS). DRAWING NOT TO BE RELIED UPON FOR ACCURACY. DRAWING NOT FOR CONSTRUCTION.

DN

DN

DN

(E)STAIR 1

(E)ELEVATOR

(E)STAIR 2

(E)STAIR 3

(E)WOMEN

(E)MEN

(E)ELEVATOR

LOBBY

OPEN TO

BELOW

36"

CLR.

CR

C R

CR

A

1.5 2 3 4 5 6 7 87.5

B

C

D

C.5

A.5

PROSTHETICS STORAGE

PROSTHETICS SHARED SPACE

PURCH AGENT

PROSTHETICS REP

HUD/VASH

SECOND FLOOR WAITING AREA

EYE ROOM

GLASSES VENDOR

PHOTOG/TEST

OPEN OFFICE

MULTIDISCIPLINARY RM 2

MAINT. STORAGE

EYE ROOM

EYE ROOM

EYE CLINIC

STORAGE

MULTIDISCIPLINARY RM 1

XEROX

SPD STORAGE

TH/INTERVIEW 1

PC TECH

TH/INTERVIEW 2

STAFF OFFICE

JANITOR

UNION OFFICE

HALLWAY

STORAGE

EYE ROOM

ADJACENT TENANTADJACENT TENANTADJACENT TENANTADJACENT TENANT

HBPC SUPPORTHBPC SUPPORTHBPC SUPPORTHBPC SUPPORT

HBPC STORAGEHBPC STORAGEHBPC STORAGEHBPC STORAGE

TELECONFERENCETELECONFERENCETELECONFERENCETELECONFERENCE

PHONE BANKPHONE BANKPHONE BANKPHONE BANK

HBPC STAFFHBPC STAFFHBPC STAFFHBPC STAFF

MHICM STAFFMHICM STAFFMHICM STAFFMHICM STAFF

FAX/COPYFAX/COPYFAX/COPYFAX/COPY

HBPC DIRECTORHBPC DIRECTORHBPC DIRECTORHBPC DIRECTOR

HBPC ASSIST/FILEHBPC ASSIST/FILEHBPC ASSIST/FILEHBPC ASSIST/FILE

HBPC PHYSHBPC PHYSHBPC PHYSHBPC PHYS

HBPC SUPERHBPC SUPERHBPC SUPERHBPC SUPER

ADMINISTRATIVE OFFICERADMINISTRATIVE OFFICERADMINISTRATIVE OFFICERADMINISTRATIVE OFFICER

EMPLOYEE BREAK RMEMPLOYEE BREAK RMEMPLOYEE BREAK RMEMPLOYEE BREAK RM

HALLWAYHALLWAYHALLWAYHALLWAY

188 KING STREET #405, SAN FRANCISCO, CA 94107

415.525.9179 | designblitzsf.com

SECOND FLOOR PLANSECOND FLOOR PLANSECOND FLOOR PLANSECOND FLOOR PLAN

3841 BRICKWAY BLVD., SANTA ROSA, CA 95403

ISSUE DATE: 02/03/15

PROJECT NUMBER: 049-01

VETERANS ADMINISTRATION

1/8" = 1'-0" 1/8" = 1'-0" 1/8" = 1'-0" 1/8" = 1'-0"A2A2A2A2

2 VA SECOND FLOOR TENANT AREA

SECOND FLOOR EXISTING FLOOR PLAN BASED ON OWNER PROVIDED INFORMATION, FIELD VERIFICATION REQUIRED TO ESTABLISH ACCURACY (INCLUDING INDICATED PLUMBING FIXTURE LOCATIONS). DRAWING NOT TO BE RELIED UPON FOR ACCURACY. DRAWING NOT FOR CONSTRUCTION.

File details come from the government source that posted it. Updated .