About this file

This document contains a submittal for hydraulic elevators and the related federal contract opportunity solicitation number 36C26120R0006. The submittal provides shop drawings and details for hydraulic elevators to be installed at the VA Sunnyvale Campus building 1002 as part of the project to correct life safety deficiencies in the lobby. Relevant details include specifications for hoistway and machine room plans, entrance plans and details, cab plans and details, and operating panels. The related federal contract opportunity is a competitive solicitation set aside for verified Service-Disabled Veteran-Owned Small Businesses to perform the lobby renovation and safety corrections project. The estimated posting date is December 13, 2019 with bids due January 13, 2020. The solicitation and amendments will be available at beta.SAM.gov and it is the bidder's responsibility to check the website for notices and changes. The solicitation will be evaluated according to FAR Part 15 and has a NAICS code of 236220 with a small business size standard of $39.5 million. The magnitude of the construction project is between $250,000 and $500,000.

36C26120R0006 0002 Submittal 14 24 00-B-Rev.03- Hydraulic Elevators.pdf

View the file

Other files

File Type Posted
36C26120R0006-0003002.pdf PDF
36C26120R0006-0003001.pdf PDF
36C26120R0006-0003000.docx DOCX document
36C26120R0006-0003003.pdf PDF
36C26120R0006-0002000.docx DOCX document
36C26120R0006-0002001.pdf PDF
36C26120R0006-0002005.pdf PDF
36C26120R0006-0002003.docx DOCX document
36C26120R0006-0002004.pdf PDF
36C26120R0006-0001000.docx DOCX document
36C26120R0006-0001001.pdf PDF
36C26120R0006-006.pdf PDF
36C26120R0006-002.pdf PDF
36C26120R0006-004.pdf PDF
36C26120R0006-003.pdf PDF
36C26120R0006-005.pdf PDF
36C26120R0006-001.docx DOCX document
Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A Service-Disabled Veteran-Owned Small Business

SUBMITTAL

15800 SE 135th Avenue, Clackamas, OR 97015 Phone: 503-650-1720

Fax: 503-650-1902

Project: VAPAHCS Sunnyvale –

Building 1002 Seismic Retrofit and

Lobby addition

Contract/Project Number:

VA261-15-C-0018 / 640-379

Submittal Title: Hydraulic Elevators

Spec Section No: 14 24 00

Submittal No.: 14 24 00-B-Rev.03

Revision No: 0

Sent Date: 11-18-15

Contractor Stamp:

Architect / Owner Stamp:

Glen/Mar Construction

Submittal #

This drawing or submittal has been review for compliance with plans and specifications and coordination with the work of others. Approval does not relieve supplier or subcontractor of responsibility for errors, omissions, or noncompliance with the correct documents.

_ Approved Approved as noted

Revise and resubmit

By:_____________________ _ Date:_____

REMARKS:

This resubmittal includes the Hydraulic Elevators shop drawing that showing actual field conditions.

Copy to: File/ Field Glen/Mar Construction, Inc.

Signed Project Engineer

Dennis Becker, CO- VA Cc: Albert Bylund, COR- VA Cc: Tim Mo’unga, Inspector- APSI kevinm Typewritten Text 052.04 kevinm Typewritten Text X kevinm Typewritten Text Kevin R. Mitchell kevinm Typewritten Text 11-18-15

Fax: 503-650-1902

Hydraulic Elevators

(14 24 00)

Shop drawing

Sheet 100: General Data

Sheet 101: Hoistway Plan View

Sheet 102: Machine Room Plan View

Sheet 103: Hoistway Section and Rail Schedule

- Hoistway section

- Rail and Brackets schedule

Sheet 104: Hoistway Details A. Rail bracket at pit B. Rail bracket steel column

D. Jack/pit channels detail E. Guide rails union detail

Sheet 201: Entrance Plan, Elevation and Section (Elev#1)

Sheet 202: Entrance Plan, Elevation and Section (Elev#2)

Sheet 203: Entrance Detail A. Door @ passing side B. Door @ strike side C. Head Jamb detail D. Access switch E. Sill angle @ concrete slab

Sheet 301: Cab and Ceiling Plan Views (Elev. #1)

- Cab plan view

- Roof plan view

Fax: 503-650-1902

Sheet 302: Cab and Ceiling Plan Views (Elev. #2)

- Cab plan view

- Roof plan view

Sheet 303: Cab Elevations (Elev. #1)

Sheet 304: Cab Elevations (Elev. #2)

Sheet 305: Cab Details (Elevs. #1 and #2)

Sheet 401: Car Operation Panel (Elev. #1)

Sheet 402: Car Operation Panel (Elev. #2)

Sheet 403: Hall stations (Elevs. #1 and #2)

Sheet 404: Combo Hall POS IND (Elevs. #1 and #2)