36C26119R0026 0002 Circuit Schedule for Headwall units.pdf

View the file

Other files

File Type Posted
36C26119R0026-0002000.docx DOCX document
36C26119R0026-0002011.pptx PPTX presentation
36C26119R0026-0002010.pdf PDF
36C26119R0026-0002006.jpg JPG image
36C26119R0026-0002005.jpg JPG image
36C26119R0026-0002012.pdf PDF
36C26119R0026-0002001.pdf PDF
36C26119R0026-0002003.jpg JPG image
36C26119R0026-0002004.jpg JPG image
36C26119R0026-0002002.pdf PDF
36C26119R0026-0002008.pdf PDF
36C26119R0026-0002007.jpg JPG image
36C26119R0026-0001000.docx DOCX document
36C26119R0026-0001001.pdf PDF
36C26119R0026-007.pdf PDF
36C26119R0026-008.pdf PDF
36C26119R0026-002.docx DOCX document
36C26119R0026-004.docx DOCX document
36C26119R0026-006.pptx PPTX presentation
36C26119R0026-010.pdf PDF
36C26119R0026-005.pdf PDF
36C26119R0026-011.pdf PDF
36C26119R0026-003.docx DOCX document
36C26119R0026-009.pptx PPTX presentation
36C26119R0026-001.docx DOCX document
36C26119R0026-000.docx DOCX document
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

20A Emergency

Receptacle

20A Normal

Receptacle

20A Single

Outlet for Bed

1A-24 2 L1EX - 3 L1E2 - 1 L1E2 - 34

1A-25 2 L1EX - 3 L1E2 - 13 L1E2 - 34

1A-39 2 L1EX - 27 L1E1 - 40 L1E2 - 36

1A-40 1 L1EX - 27 L1E1 - 19 L1E2 - 36

1A-42 1 L1EX - 30 L1E1 - 11 L1E2 - 36

1A-44 1 L1EX - 30 L1E1 - 11 L1E2 - 36

1A-46 1 L1EX - 5 L1E1 - 42 L1E2 - 38

1A-48 1 L1EX - 5 L1E1 - 42 L1E2 - 38

1A-50 1 L1EX - 5 L1E1 - 3 L1E2 - 38

1A-51 2 L1EX - 4 L1E1 - 3 / 8 L1E2 - 38

1A-52 1 L1EX - 4 L1E1 - 8 L1E2 - 40

1A-54 1 L1EX - 6 L1E1 - 16 L1E2 - 40

1A-56 1 L1EX - 6 L1E1 - 24 L1E2 - 40

1A-59 2 L1EX - 32 L1E1 - 11 L1E2 - 42

1A-60 1 L1EX - 32 L1E1 - 2 L1E2 - 42

1A-61 1 L1EX - 32 L1E1 - 2 L1E2 - 42

1. Circuit numbers noted are from As-built drawings and for reference only. Contractor is responsible to investigate existing conditions and verify existing load on each circuit being reused.

2. ALL duplex and single receptacles to be 20A Hospital Grade type, no exception.

3. Receptacle designated for “Emergency” shall have a red outlet and cover plate.

4. Grayed-Out circuit shown in this table to indicate:

Provide new 2#12, 1#12G – 3/4" C. Extend back to existing panel and reuse existing 20A C/B.

5. Contractor is responsible to provide a complete installation in accordance with all required codes.

Existing circuits being affected by this upgrade/ replacement with new headwall units shall also have the correct conductors throughout the run and the home-run back to panel. The contractor shall provide a neutral conductor for each home-run, per code.

Headwall Unit ONLY - Existing/New power source.

Project #662-17-008 - Replace upgrade Med Gas and Headwalls

Patient

Room

Headwall

Unit Notes